Brochure from Schiedel. This forms part of our flue and chimney range and can be used with acknowledgement to Schiedel Chimney Systems Ltd. as well as a link to the original source at www.schiedel.com/uk
Schiedel's chimney flue range includes flue systems for residential and commercial applications. A typical flue installation includes steel chimney pipe or mineral pipe or module components from the heat source appliance (a stove, biomass or gas appliance for example) to it's termination point above the roof. Support is required for internal and external chimney systems.
Schiedel specialise in wood burning appliances and flues, which are a renewable way of avoiding constant gas or electricity usage when looking at a secondary heat source. Even heat pumps are problematic with severe temperature drops, so a secondary source is always needed.
2. 2
System Description
Metaloterm®
ME system is a modular single wall flue/chimney system, made of stainless
steel with a high temperature sealing ring.
Metaloterm®
ME is a universal flue/chimney system which is suitable for both high and
low temperatures, non-condensing and condensing applications with flue gasses under
positive and negative pressure. It can resist a chimney fire.
Therefore the system is suitable for a wide range of applications such as boilers, stoves,
ovens and a ventilation system. It can be used as a connecting flue pipe or in renovation
situations as a liner an existing chimney.
The product range also contains a wide variety of silencers.
The system can also be used for CHP applications, in this case a special VITON®
sealing
ring might be necessary.
• Flue system for condensing heaters and boilers
• Air inlet & ventilation systems
• Connecting flue pipe
• Chimney renovation
Free thermal expansion
Interfits with Metaloterm®
MF and UE
High quality stainless steel system
Incorporates silicone sealing ring
Universal application
Light weight
Chimney fire resistant
Applications
Advantages A
C
C
D
B
B
B
3. 3
Technical characteristics
Technical characteristics
Application System Chimney/Connecting Flue Pipe/Chimney
Liner
Operating mode Dry/wet
Pressure N1/P1/H1
Max. working pressure 5000 Pa
Max. operating temperature 600°C (negative pressure - N1 applications)
200°C (positive pressure - P1/H1 applications)
Soot Fire Resistant* Yes (see G designations below)
No (see O designations below)
Inner wall material AISI 316L/EN 1.4404
thickness Ø80 - Ø600: 0,6
Ø700 - Ø800: 0,8
Ø900 - Ø1000: 1,0
Fuel type Oil/wood/coal/pellets normal (wood)/gas
Sealant Elastomer. (Where case flue gas temperatures
exceed 200°C, sealants as well as the cap and
door seals should be removed before installation)
Chimney diameter
Diameter
(mm)
80 100 113 130 150 180 200 250 300 350 400 450 500 600 700* 800* 900* 1000*
Cross section
(cm2
)
50 79 100 133 177 254 314 491 707 962 1256 1590 1963 2826 3848 5027 6362 7854
Weight
(±kg/m)
1.5 1.5 2 2 2.5 3 3 4 4.5 5.5 6 7 8 9.5 14.5 16.6 23.4 26
CE approved*
EN 1856-1: System Chimney T200 P1/H1 W V2 L50050 O30
EN 1856-2:
Connecting Flue Pipe T200 P1/H1 W V2 L50050 O30 M
T600 N1 D V2 L50050 G400 M
EN1856-2: Chimney Liner T200 P1/H1 W V2 L50050 O
T600 N1 D V2 L50050 G
* Above CE designations refer to Ø80-300 - For larger diameters refer to Schiedel Metaloterm website.
4. 4
A. Maximum height above Tee piece when chimney is supported by wall support at base.
B. Maximum height that can be borne by a wall support.
C.
Maximum distance between lateral supports i.e. wall bands and wall supports.
D. Maximum free standing height above last support.
- For non-vertical parts of the flue system, the maximum distance between two wall bands i.e. brackets is 1,5 m
- In case of a condensing application a slope of 3° is required on horizontal systems to allow condensate to run off.
Mounting heights and distances
Ø (mm) 80 100 113 130 150 180 200 250 300 350 400 450 500 600
A (m) MET 45 50 50 50 50 50 40 35 30 30 25 22 15 11 9
MET 87/90 50 50 50 50 50 40 35 30 30 25 22 15 11 9
MERE/MEI - - 50 50 50 40 35 30 30 25 22 - - -
METV 50 50 50 50 50 40 35 30 - - - - - -
B (m) MEOL 1/2 30 30 30 30 30 30 30 30 30 - - - - -
MEMO 50 50 50 50 50 40 35 30 30 25 22 15 11 9
MEOH 1/2 30 30 30 30 30 30 30 30 30 30 30 30 30 30
MEAPO - - - - - - - - - 30 30 30 30 30
MEZS* 10 10 10 10 10 10 10 - - - - - - -
MEAP - - - - 10 10 10 10 10 10 10 - - -
MEZS - - 20 20 20 20 20 20 - - - - - -
MEDD - - 20 20 20 20 20 20 20 20 - - - -
MEBBS - - - - - - 10 10 10 10 10 - - -
MEBS 10 10 10 10 10 10 - - - - - - - -
MEAUP 10 10 10 10 10 10 10 10 10 10 10 - - -
C (m) MEMB 4 4 4 4 4 4 4 4 4 4 4 4 4 4
MEMO - - - - 4 4 4 4 4 4 4 4 4 4
MEAH 3 3 3 3 3 3 3 3 3 3 3 3 3 3
MEEB 3 3 3 3 3 3 3 3 - - - - - -
D (m) MEMB 2 2 2 2 2 2 2 2 2 2 2 1.5 1.5 1.5
MEMBV - - - - 2 2 2 2 2 2 2 1.5 1.5 1.5
MEMBV
+MESK
- - - - - 3 3 3 3 3 3 3 3 3
MEMO 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1 1 1
MEEB 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 - - - - - -
* Provided that the joints above and below the last connection point are reinforced with a structural locking band (MESK)
Installation Guidelines
7. 7
Ø
G
H
3/4
Pipe Lengths
Ø
L
100
3/4 (450-600=1)
Condensate Collector with Drain Point Old Code MEEMC
Ø 80 100 113 130 150 180 200 250 300 350 400 450 500 600
L 150 150 150 150 150 150 150 145 145 155 155 155 155 155
SAP Code - 161177 - 161178 161179 161180 161181 161182 161183 161184 161185 161186 161187 161188
Inspection Element Old Code MEI
Ø 80 100 113 130 150 180 200 250 300 350 400 450 500 600
H 200 200 200 250 250 250 250 300 300 300 350 400 400 400
G 65 100 100 130 140 140 140 180 180 180 240 240 240 240
SAP Code 161196 161197 161198 161199 161200 161201 161202 161203 161204 161205 161206 161207 161208 161209
Ø
H
G
Locking Band Old Code MEKB
Ø 80 100 113 130 150 180 200 250 300 350 400 450 500 600
SAP Code 161273 161274 161275 161276 161277 161278 161279 161280 161281 161282 161283 161284 161285 161286
* For internal use only
Locking Band with Screw Fitting Old Code MEKBS
Ø 80 100 113 130 150 180 200 250 300 350 400 450 500 600
SAP Code 161290 161291 161292 161293 161294 161295 161296 1161297 161298 161299 161300 161301 161302 161303
* For internal use only
Ø
17
Ø
25
Reinforced Locking Band Old Code MESK
Ø 80 100 113 130 150 180 200 250 300 350 400
SAP Code 161533 161534 161535 161536 161537 161538 161539 161540 161541 161542 161543
210
Ø
Seals
Ø 80 100 113 130 150 180 200 250
SAP Code VITON 160574 160575 * 160576 160577 160578 160579 160582
For oil-containing exhaust gases
SAP Code EPDM 900012188 900012189 900012190 9000121191
For temperatures always below 120 degrees
Inspection Element with Condensate Drain Old Code MEKI
Ø 80 100 113 130 150 180 200 250 300 350 400
H 200 200 200 250 250 250 250 300 300 300 350
G 65 100 100 130 140 140 140 180 180 180 240
SAP Code * * * 161308 161309 161310 161311 * * * *
8. 8
Absorption Silencer Old Code MESIA
Ø 80 100 130 150 180 200 250 300 350 400 450 500 600
L 600 600 600 600 780 780 780 1140 1140 1140 1140 1140 1140
A 180 200 230 250 280 300 350 400 450 500 550 600 700
kg 4.5 5 6 6.5 9.5 10 12 19.5 22 25 27.5 30 36
SAP Code 161465 161466 161467 161468 161469 161470 161471 161472 * * * * *
Absorption Silencer 25 dB Old Code MESIA 1
Ø 80 100 130 150 180 200 250 300 350 400 450 500 600
L 580 580 730 730 980 1230 1230 1730 1730 1730 1970 1970 1970
A 205 225 255 275 305 325 375 425 475 525 575 625 725
kg 8 8 10 11 15 20 24 49 55 60 79 86 100
SAP Code 161478 161479 161480 161481 161482 161483 161483 161484 161485 * * * *
Absorption Silencer 35 dB Old Code MESIA 2
Ø 80 100 130 150 180 200 250 300 350 400 450 500 600
L 980 980 980 980 1230 1480 1480 2480 2480 2480 2970 2970 2970
A 205 225 255 275 325 325 375 425 475 525 575 625 725
kg 12 12 13 14 20 24 28 68 76 84 117 127 146
SAP Code 161490 161491 161492 161493 161494 161495 161496 * * * * * *
Average performance MESI A / MESIA1 / MESIA2 80 - 600 Pressure drop MESIA / MESIA1 / MESIA2 80 - 600
Performance chart is an average measurement over all diameters.
The insertion loss is measured according to iso 7235: 2003
The insertion loss can deviate due to temperature or special installation situations.
Back pressure is approx. 20 Pa at 15m/s or 200 Pa at 50 m/s
Back pressure can vary with temperature and gas velocity, please contact Ontop for advice
For installation brackets of a corresponding outerdiameter can be used.
40
35
30
25
20
15
10
5
0
Frequency [Hz] Fluegass velocity [m/s]
MESIA MESIA 1 MESIA 2
Noise
reduction
[dB]
Pressure
[Pa]
250 500 1000 2000 4000 8000 16000
180
160
140
120
100
80
60
40
20
0
10 15 20 25 30 35 40 45 50
Absorption type silencer
L
Ø
A
A
L
Ø
A
L
Ø
Silencers
9. 9
Resonance Silencer 20 dB Old Code MESIR 1
Ø 80 100 130 150 180 200 250 300 350 400 450 500 600
L 2000 2000 2000 2000 2000 2000 2000 2000 2100 2100 2100 2400 2400
A 225 275 325 350 400 450 525 625 725 825 925 1025 1225
kg 16 20 25 27 33 38 46 47 71 84 98 122 156
SAP Code * * * * * * * * * * * * *
Lifting eyes standard for ø ≥ 130
Resonance Silencer 30 dB Old Code MESIR 2
Ø 80 100 130 150 180 200 250 300 350 400 450 500 600
L 2000 2000 2000 2000 2000 2000 2200 2400 2600 2800 3000 3200 3400
A 350 450 550 650 700 750 900 900 1000 1100 1200 1250 1450
kg 35 45 55 70 75 85 115 125 140 160 185 230 305
SAP Code 161520 161521 161522 161523 161524 161525 161526 161527 161528 161529 161530 161531 161532
Lifting eyes standard for ø ≥ 130
Average performance MESIR1 / MFSIR2 80 - 600 Pressure drop MESIR1 / MESIR2 0 - 600
Performance chart is an average measurement over all diameters.
The insertion loss is measured according to iso 7235: 2003
The insertion loss can deviate due to temperature or special installation situations.
Back pressure is approx. 300 Pa at 15m/s or 2300 Pa at 50 m/s
Back pressure can vary greatly with temperature and gas velocity, please contact
Ontop for advice
EXTRA OPTIONS
Brackets (installation direction to be
specified rder)
Radial / axial inlet
Radial / axial outlet
(certified) spark arrestor
Flanged
STANDAARD OPTIONS
condensate drain
lifting eyes
45
40
35
30
25
20
15
10
5
0
Frequency [Hz] Fluegass velocity [m/s]
ADSIR 1 ADSIR 2
Noise
reduction
[dB]
Pressure
[Pa]
31.5 63 125 250 500 1000
2500
2000
1500
1000
500
0
10 15 20 25 30 35 40 45 50
Resonance silencer
A
L
Ø
Ø
L
A
Silencers
10. 10
Silencers
Combination Silencer 25 dB Old Code MESIC 1
Ø 80 100 130 150 180 200 250 300 350 400 450 500 600
L 1850 1850 1850 1850 2100 2350 2600 3100 3350 3850 4340 4590 4840
A 250 300 400 425 475 525 675 775 875 950 1000 1125 1225
kg 21 27 41 45 60 78 130 192 252 327 393 511 600
SAP
Code
* * * * * * * * * * * * *
Lifting eyes standard for ø ≥ 130
Average performance MESIC1 80 - 600
Performance chart is an average measurement over all diameters.
The insertion loss is measured according to iso 7235: 2003
The insertion loss can deviate due to temperature or special installation situations.
Back pressure is approx. 20 Pa at 15m/s or 200 Pa at 50 m/s
Back pressure can vary with temperature and gas velocity, please contact Ontop for
advice Performance chart is an average measurement over all diameters.
The insertion loss is measured according to iso 7235: 2003
The insertion loss can deviate due to temperature or special installation situations.
Back pressure is approx. 350 Pa at 15m/s or 2500 Pa at 50 m/s
Back pressure can vary greatly with temperature and gas velocity, please contact Ontop
for advice
EXTRA OPTIONS
Brackets (installation direction to be specified on order)
Radial / axial inlet
(certified) spark arrestor
STANDAARD OPTIONS
condensate drain
lifting eyes
Frequency [Hz]
MESIC1
Noise
reduction
[dB]
30
25
20
15
10
5
0
31.5 63 125 250 500 1000 2000 4000 6000 8000 16000
A
L
Ø