The increase of knowledge in all areas of research forms the premises for an increase in the life expectancy of the population as well as the quality of life, this increase of life expectancy are achieved through efficient medical care to meet the main objectives of improving and ensuring an adequate mobility for performing daily tasks.
2. INTRODUCTION
The increase of knowledge in all areas of research forms the premises for an increase in
the life expectancy of the population as well as the quality of life, this increase of life
expectancy are achieved through efficient medical care to meet the main objectives of
improving and ensuring an adequate mobility for performing daily tasks [1].
For this maximum mobility the hip joint is a major structure within the human body, it
supports most of the upper body weight.
3. The hip joints are connecting the torso
to the legs and, the weight of the upper
body and decrease the impulsion loading
from lower body to the upper body.
Experimental studies have found that
the resultant force acting through the hip
joint during normal walking is around
300% body weight. Having known the
load, the hip joint could be destroyed
under complex working conditions and
needs to be replaced. [2]
4. CONTD..
The replacement of the natural hip with artificial replacement is the most effective way of restoring
mobility for patients that suffer from chronic diseases such as osteoarthritis, chronic arthritis and
severe trauma. Attempts at replacing the diseased hip joint can be traced back as far as 1890 when
Gluck described the use of ivory to replace the femoral head. Early attempts were largely
unsuccessful and more recent developments in hip prostheses owe much to the work of Charnley in
the 1960s and 1970s. [3]
Since the 1950's, a very common solution to the debilitating pain associated with this condition has
been a procedure termed Total Hip Arthroplasty, or Total Hip Replacement (THR). The first
"highly successful" device was designed by Charnley in the mid-1950 and to the present.
5. CONTD..
The first "highly successful" device was
designed by Charnley in the mid-1950 and to the present, the fundamental design has remained
virtually unchanged, though many incremental improvements have occurred, particularly as a
result of materials advances.
A total hip replacement device consists of two primary components: the femoral head/ and stem,
and the ace tabular component.[4]
The story of replacement hip joint engineering and surgery represents but one aspect of progress in
bio-tribology. Everyone seems to know of someone who has benefited from hip joint replacement.
The field has been dominated for some forty years by implants based articulation. [5]
6. RESEARCH OBJECTIVES
• General Objective: Minimization of stress concentration developed on contact surface between
the stem neck and the conical borehole of the artificial femur head in hip joint prosthesis. This can
be achieved by varying the borehole shapes design and selecting the proper prosthetic material.
• Specific objectives
General evaluation of mechanical reliability for femur head in terms of stress concentration.
Determining the effect of taper bore conical contact length using FEM.
Analyzing the stress concentration on femur head considering design of borehole geometry.
Minimizing the stress till having the safe zone with minimum value.
Recommending the feasible borehole geometry and the material we should be using in future
implant surgery
7. LITERATURE REVIEW
• Femur Bone - The femur is the longest and strongest bone in the body of the skeleton, with the
thickened shaft preferentially preserving in archaeological deposits. Long bones are characterized by a
shaft, the diathesis that is much longer than it is wide. The femur bone is the most proximal bone of the
leg in vertebrates capable of walking or jumping. .
• Femur Borehole Shape- The structure, geometrical shape and material are the three main parts of the
femur of hip joint prostheses. The geometrical shape of human natural femoral head is similar to the
ellipse, but, the artificial femoral head is rotundity shape. There is difference between ellipse and
rotundity femoral head.
• Implant Material Review- A material used as an artificial body is known by biomaterial which is a
material that interacts with human tissue and body fluids to treat, improve, or replace anatomical
element(s) of the human body
8. CONTD..
•Force and Stress on Femur Head prosthesis- Knowledge of the forces acting on the human femur
is of significant importance to health care professionals. Determination of these forces during
walking and other daily living activities allows the subsequent calculation of the stresses induced in
the femur and therefore the localization of the areas of frequent appearance of femur fractures.
•The Stress Analysis Methods- The mathematical methods for the determination of the stress
distribution inside the femur necessitate the construction of a model from the actual femur; therefore
they are indirect methods. Recourse to a model simulating the real femur is needed for the application
of the principles of these methods to the solution of the existing problems. The model should take
into account the essential properties of the femur and it should adequately describe the reality.
9. Finite Element Analysis (FEA)
The Finite Element Analysis (FEA) is a numerical method for solving
problems of engineering and mathematical physics.
Useful for problems with complicated geometries, loadings,
and material properties where analytical solutions can not be
obtained.
12. Feature
Obtain a set of algebraic equations to solve for unknown (first) nodal
quantity (displacement).
Secondary quantities (stresses and strains ) are expressed in terms of
nodal values of primary quantity
16. REFERENCES
[1] Eng. Radu RACA'AN,( 2011) Contributions Regarding the use of Modern
Techniques for Measuring and Modeling Complex Surfaces in the Wear
Evaluation of Total Hip Replacements, Appointed through order nr. 372/02.08
issued.
[2]JIANG Hai-bo, LIU Hong-tao, HAN Shu-yang, LIU Fen, Biomechanics
Characteristics of New Type Artificial Hip Joint, Advances in Natural Science
Vol. 3, No. 2, 2010, pp. 258-262, www.cscanada.net
[3]J. Lord, T. Joyce, Analysis of failed metal-on-metal hip prostheses, pp: 1
[4]Dianne-Anand , Wear Analysis of Acetabular Components in a Total Hip
Replacement, pp:1
[5]D Dowson, New joints for the Millennium: Wear control in total replacement
hip joints, Journal of Engineering in Medicine 215: 335
[6]R.W. Buchoz, J.D. Heckman, C.M. Cort-Brown, K.J. Koval, P. Tornetta III, and M.A. Wirth, "Rockwood and
Green's Fractures in Adults Volume 2," 6th ed, Lippincott Williams & Wilkins, 2001.
17. [7][http://www.thehipdoc.com/history.htm]
[8][http://www.utahhipandknee.com/history.htm]
[9]Charnley, J: (1964) The bonding of prosthesis to bone by cement. J. Bone JntSura.
46B. 518-529.
[10]Charnley, J. (1965) A biomedical analysis of the use of cement to anchor the
femoral head prosthesis. J. BoneJnt Surg. 47B, 354-363.
[11]Charnley, J. and Smith, D. C. (1968) The physical and chemical properties of
self-curing acrylic cement for use in orthopaedic surgery. Centre of Hip Surgery,
Wrightington Hospital, Int. Pubn. No. 16
[12]Sumit Pramanik, Avinash Kumar Agarwal, and K. N. Rai, (2005) Chronology of
Total Hip Joint Replacement and Materials Development, Trends Biomater.
Artif. Organs, Vol 19(1), pp. 15-26