Introduction
Universal Block Interface Equipment UBX 2000 is a failsafe equipment envisaged to become an integral
partof the Railways Signal Communication Scheme. Designed and developed indigenously at WEBFIL, the
equipment is ready for incorporation into the services of the Indian Railways.
Scope
The Universal Block interface equipment UBX 2000 is meant for interfacing various signaling information of a
block instrument at one end of a block section, and exchanging them with the block interface equipment at
other end, through digital transmission equipment (Optical or Radio), ensuring high degree of safety and
availability.
A foolproof logic sequence and relay interlocking ensure safety of a Block instrument. Safety for the block
equipment means correct acquiring of the signal and error – free reproduction at the other end. Any deviation
or failure detected leads the systems to a failsafe state.
Safety First & Safety Always
The scope of use of UBX 2000 leaves no room for error and this fact has been the guiding principle in
designing and manufacturing of this product. Watchdog procedure has been incorporated at every stage of its
functioning in both hardware and software levels. Numerous crosschecks & feedback precede any action.
This combined with the 2/3 – majority decision logic derived from the three individual processors acting
independently makes the system failsafe and tamper – proof. Stringent quality control procedure at every
stage starting right from procurement up to the final testing ensures heavy –duty performance under diverse
environmental conditions.
Features
Simple, modular and rugged design.
Designed for fail –safe operation.
Triple redundant hardware at all levels with 2/3 decision logic ensuring high degrees of safety and at the same
time allowing availability.
Systems meets CENELEC & ORE 155 guidelines for safety and reliability
Systems meet RDSO specification SPN144 and SPN147/97 for all types of Block Instruments in operation in
Indian Railways.