DAR GROUP
Project
The Pearl
Job Ref.
Q09079
Section
PA
Sheet no./rev.
1
Calc. by
Eng.MS
Date
09-July-06
Chk'd by
Eng.AE
Date App'd by Date
RC SINGLE CORBEL DESIGN TO ACI 318-05
Vu
Nuc
a
d h
Framing
bars
Main
tension
bars
Horizontal
bars
Steel angle
mind/2
Shd
2
3
Sh
Sh
Corbel geometry
Width of corbel; b = 300 mm
Total thickness of corbel; h = 500 mm
Depth to main reinforcement; d = 450 mm
Material properties
Yield strength of reinforcement; fy = 415 MPa
Compressive strength of concrete; f’c = 35 MPa
Type of concrete; Normal weight
Unit weight of concrete;  = 1.00
Corbel construction; Monolithic
Coefficient of friction;  = 1.4   = 1.40
Design load data
Factored vertical load; Vu = 370.00 kN
Distance of vertical load from face of column; a = 100 mm
Horizontal force acting on corbel; Nuc = 75.00 kN
Strength reduction factor;  = 0.750
Vertical load capacity check
Nominal vertical load; Vn = Vu / = 493.33 kN
Nominal vertical load capacity; Vn_cap = min(0.2  f’c  b  d, 5.5 MPa  b  d) = 742.50 kN
PASS - Nominal vertical load is less than the nominal vertical load capacity
Find shear friction reinforcement
Minimum horizontal force acting on corbel; Nuc_min = 0.2  Vu = 74.00 kN
Horizontal force acting on corbel; Nuc_act = max(Nuc, Nuc_min) = 75.00 kN
For balanced condition; j = 0.85
Area for shear friction reinforcement; Avf = Vn / (fy ) = 849 mm2
Af = [(Vu  a) + (Nuc_act  (h –d))] / (  fy  j  d) = 342 mm2
Nominal area required; An = Nuc_act / ( fy) = 241 mm2
DAR GROUP
Project
The Pearl
Job Ref.
Q09079
Section
PA
Sheet no./rev.
2
Calc. by
Eng.MS
Date
09-July-06
Chk'd by
Eng.AE
Date App'd by Date
Main tension reinforcement check
Minimum area of tension reinforcement; Asc_min = 0.04  f’c  b  d / fy = 455 mm2
Area of tension reinforcement required; Asc = max([(2  Avf) / 3] + An, Af + An) = 807 mm2
Asc_req = max(Asc, Asc_min) = 807 mm2
Main tension reinforcement; 3 No.6 bars
Diameter of tension bars; Dtension = 19 mm
Number of tension bars; Ntension = 3
Area of tension reinforcement provided; Asc_prov = Ntension    Dtension
2
/ 4 = 851 mm2
PASS - Tension reinforcement is adequate
Horizontal reinforcement check
Minimum area of horizontal reinforcement; Ah_min = 0.5  (Asc_req - An) = 283 mm2
Area of horizontal reinforcement required; Ah = max(Avf / 3, Af / 2) = 283 mm2
Ah_req = max(Ah, Ah_min) = 283 mm2
Horizontal reinforcement; 3 No.3 bars
Diameter of horizontal bars; Dhorizontal = 9 mm
Number of horizontal bars; Nhorizontal = 3
Area of horizontal reinforcement provided; Ah_prov = 2  Nhorizontal    Dhorizontal
2
/ 4 = 382 mm2
PASS - Horizontal reinforcement is adequate
Maximum spacing of horizontal bars; Sh_max = 2  d / (3  Nhorizontal) = 100 mm
Actual spacing of horizontal bars; Sh = 100 mm
PASS - Horizontal bar spacing is adequate
Design Summary
Single corbel 300 mm wide by 500 mm deep with 35 MPa concrete and 415 MPa steel
Provide main tension reinforcement as 3 No. 6 bars
Provide horizontal reinforcement as 3 No. 3 link bars at maximum 100 mm centres

More Related Content

What's hot

BIAXIAL COLUMN DESIGN
BIAXIAL COLUMN DESIGNBIAXIAL COLUMN DESIGN
BIAXIAL COLUMN DESIGN
shawon_sb
 

What's hot (20)

Design of column base plates anchor bolt
Design of column base plates anchor boltDesign of column base plates anchor bolt
Design of column base plates anchor bolt
 
Design of floor slab
Design of floor slabDesign of floor slab
Design of floor slab
 
Design of combined footing ppt
Design of combined footing pptDesign of combined footing ppt
Design of combined footing ppt
 
BIAXIAL COLUMN DESIGN
BIAXIAL COLUMN DESIGNBIAXIAL COLUMN DESIGN
BIAXIAL COLUMN DESIGN
 
PPT ON DESIGN OF COLUMN BRACES
PPT ON DESIGN OF COLUMN BRACESPPT ON DESIGN OF COLUMN BRACES
PPT ON DESIGN OF COLUMN BRACES
 
Prestressed concrete continuous beam
Prestressed concrete continuous beamPrestressed concrete continuous beam
Prestressed concrete continuous beam
 
crack control and crack width estimation
crack control and crack width estimationcrack control and crack width estimation
crack control and crack width estimation
 
Design of arch bridges
Design of arch bridgesDesign of arch bridges
Design of arch bridges
 
One way slab load calculation
One way slab load calculation One way slab load calculation
One way slab load calculation
 
Column design.ppt
Column design.pptColumn design.ppt
Column design.ppt
 
ETABS manual - Seismic design of steel buildings according to Eurocode 3 & 8
ETABS manual - Seismic design of steel buildings according to Eurocode 3 & 8 ETABS manual - Seismic design of steel buildings according to Eurocode 3 & 8
ETABS manual - Seismic design of steel buildings according to Eurocode 3 & 8
 
CE72.52 - Lecture 3b - Section Behavior - Shear and Torsion
CE72.52 - Lecture 3b - Section Behavior - Shear and TorsionCE72.52 - Lecture 3b - Section Behavior - Shear and Torsion
CE72.52 - Lecture 3b - Section Behavior - Shear and Torsion
 
CSI ETABS & SAFE MANUAL: Slab Analysis and Design to EC2
CSI ETABS & SAFE MANUAL: Slab Analysis and Design to EC2CSI ETABS & SAFE MANUAL: Slab Analysis and Design to EC2
CSI ETABS & SAFE MANUAL: Slab Analysis and Design to EC2
 
Doubly reinforced beam]
Doubly reinforced beam]Doubly reinforced beam]
Doubly reinforced beam]
 
Reinforced slab
Reinforced slabReinforced slab
Reinforced slab
 
Design of steel beams
Design of steel beamsDesign of steel beams
Design of steel beams
 
Seismic Analysis
Seismic AnalysisSeismic Analysis
Seismic Analysis
 
Calulation of deflection and crack width according to is 456 2000
Calulation of deflection and crack width according to is 456 2000Calulation of deflection and crack width according to is 456 2000
Calulation of deflection and crack width according to is 456 2000
 
Design and analysis of slabs
Design and analysis of slabsDesign and analysis of slabs
Design and analysis of slabs
 
Numerical problem bearing capacity terzaghi , group pile capacity (usefulsear...
Numerical problem bearing capacity terzaghi , group pile capacity (usefulsear...Numerical problem bearing capacity terzaghi , group pile capacity (usefulsear...
Numerical problem bearing capacity terzaghi , group pile capacity (usefulsear...
 

Similar to Rc corbel example

Similar to Rc corbel example (20)

3F TO 5F BEAM DESIGN SUMMARY.pdf
3F TO 5F BEAM DESIGN SUMMARY.pdf3F TO 5F BEAM DESIGN SUMMARY.pdf
3F TO 5F BEAM DESIGN SUMMARY.pdf
 
3F TO 5F BEAM DESIGN SUMMARY.pdf
3F TO 5F BEAM DESIGN SUMMARY.pdf3F TO 5F BEAM DESIGN SUMMARY.pdf
3F TO 5F BEAM DESIGN SUMMARY.pdf
 
Base plate and anchor design
Base plate and anchor designBase plate and anchor design
Base plate and anchor design
 
Anchor bolt design
Anchor bolt designAnchor bolt design
Anchor bolt design
 
Rcc member design steps
Rcc member design stepsRcc member design steps
Rcc member design steps
 
Ch 8.pdf
Ch 8.pdfCh 8.pdf
Ch 8.pdf
 
10.01.03.153
10.01.03.15310.01.03.153
10.01.03.153
 
IRJET- Design of the Support Structure for the Pipe Line System
IRJET- Design of the Support Structure for the Pipe Line SystemIRJET- Design of the Support Structure for the Pipe Line System
IRJET- Design of the Support Structure for the Pipe Line System
 
Ch 3-a.pdf
Ch 3-a.pdfCh 3-a.pdf
Ch 3-a.pdf
 
DESIGN OF STEEL STRUCTURE
DESIGN OF STEEL STRUCTUREDESIGN OF STEEL STRUCTURE
DESIGN OF STEEL STRUCTURE
 
Analysis and Design of Residential building.pptx
Analysis and Design of Residential building.pptxAnalysis and Design of Residential building.pptx
Analysis and Design of Residential building.pptx
 
Design calculations of raft foundation
Design calculations of raft foundationDesign calculations of raft foundation
Design calculations of raft foundation
 
Chapter4b
Chapter4bChapter4b
Chapter4b
 
21-Design of Simple Shear Connections (Steel Structural Design & Prof. Shehab...
21-Design of Simple Shear Connections (Steel Structural Design & Prof. Shehab...21-Design of Simple Shear Connections (Steel Structural Design & Prof. Shehab...
21-Design of Simple Shear Connections (Steel Structural Design & Prof. Shehab...
 
Ch 3-c.pdf
Ch 3-c.pdfCh 3-c.pdf
Ch 3-c.pdf
 
Design of singly reinforced.
Design of singly reinforced.Design of singly reinforced.
Design of singly reinforced.
 
Theatre building PPT.pptx
Theatre building PPT.pptxTheatre building PPT.pptx
Theatre building PPT.pptx
 
Koppolu abishek prying action
Koppolu abishek   prying actionKoppolu abishek   prying action
Koppolu abishek prying action
 
Intze Overhead Water Tank Design by Working Stress - IS Method.pdf
Intze Overhead Water Tank  Design by Working Stress - IS Method.pdfIntze Overhead Water Tank  Design by Working Stress - IS Method.pdf
Intze Overhead Water Tank Design by Working Stress - IS Method.pdf
 
Shear lug verification example
Shear lug verification exampleShear lug verification example
Shear lug verification example
 

Rc corbel example

  • 1. DAR GROUP Project The Pearl Job Ref. Q09079 Section PA Sheet no./rev. 1 Calc. by Eng.MS Date 09-July-06 Chk'd by Eng.AE Date App'd by Date RC SINGLE CORBEL DESIGN TO ACI 318-05 Vu Nuc a d h Framing bars Main tension bars Horizontal bars Steel angle mind/2 Shd 2 3 Sh Sh Corbel geometry Width of corbel; b = 300 mm Total thickness of corbel; h = 500 mm Depth to main reinforcement; d = 450 mm Material properties Yield strength of reinforcement; fy = 415 MPa Compressive strength of concrete; f’c = 35 MPa Type of concrete; Normal weight Unit weight of concrete;  = 1.00 Corbel construction; Monolithic Coefficient of friction;  = 1.4   = 1.40 Design load data Factored vertical load; Vu = 370.00 kN Distance of vertical load from face of column; a = 100 mm Horizontal force acting on corbel; Nuc = 75.00 kN Strength reduction factor;  = 0.750 Vertical load capacity check Nominal vertical load; Vn = Vu / = 493.33 kN Nominal vertical load capacity; Vn_cap = min(0.2  f’c  b  d, 5.5 MPa  b  d) = 742.50 kN PASS - Nominal vertical load is less than the nominal vertical load capacity Find shear friction reinforcement Minimum horizontal force acting on corbel; Nuc_min = 0.2  Vu = 74.00 kN Horizontal force acting on corbel; Nuc_act = max(Nuc, Nuc_min) = 75.00 kN For balanced condition; j = 0.85 Area for shear friction reinforcement; Avf = Vn / (fy ) = 849 mm2 Af = [(Vu  a) + (Nuc_act  (h –d))] / (  fy  j  d) = 342 mm2 Nominal area required; An = Nuc_act / ( fy) = 241 mm2
  • 2. DAR GROUP Project The Pearl Job Ref. Q09079 Section PA Sheet no./rev. 2 Calc. by Eng.MS Date 09-July-06 Chk'd by Eng.AE Date App'd by Date Main tension reinforcement check Minimum area of tension reinforcement; Asc_min = 0.04  f’c  b  d / fy = 455 mm2 Area of tension reinforcement required; Asc = max([(2  Avf) / 3] + An, Af + An) = 807 mm2 Asc_req = max(Asc, Asc_min) = 807 mm2 Main tension reinforcement; 3 No.6 bars Diameter of tension bars; Dtension = 19 mm Number of tension bars; Ntension = 3 Area of tension reinforcement provided; Asc_prov = Ntension    Dtension 2 / 4 = 851 mm2 PASS - Tension reinforcement is adequate Horizontal reinforcement check Minimum area of horizontal reinforcement; Ah_min = 0.5  (Asc_req - An) = 283 mm2 Area of horizontal reinforcement required; Ah = max(Avf / 3, Af / 2) = 283 mm2 Ah_req = max(Ah, Ah_min) = 283 mm2 Horizontal reinforcement; 3 No.3 bars Diameter of horizontal bars; Dhorizontal = 9 mm Number of horizontal bars; Nhorizontal = 3 Area of horizontal reinforcement provided; Ah_prov = 2  Nhorizontal    Dhorizontal 2 / 4 = 382 mm2 PASS - Horizontal reinforcement is adequate Maximum spacing of horizontal bars; Sh_max = 2  d / (3  Nhorizontal) = 100 mm Actual spacing of horizontal bars; Sh = 100 mm PASS - Horizontal bar spacing is adequate Design Summary Single corbel 300 mm wide by 500 mm deep with 35 MPa concrete and 415 MPa steel Provide main tension reinforcement as 3 No. 6 bars Provide horizontal reinforcement as 3 No. 3 link bars at maximum 100 mm centres