Guide for the Design and Construction of 
Externally Bonded FRP Systems for 
Strengthening Concrete Structures 
Reported by ACI Committee 440 ACI encourages the development and appropriate use of new and emerging technologies com 
through the publication of the Emerging Technology 
Series. This series presents information and recommendations based on available test data, technical reports, limited experience with field 
applications, and the opinions of committee members. The presented information and recommendations, and their basis, may be less fully de-veloped 
and tested than those for more mature technologies. This report identifies areas in which information is believed to be less fully de-veloped, 
and describes research needs. The professional using this document should understand the limitations of this document and exercise 
judgment as to the appropriate application of this emerging technology. 
Charles E. Bakis Ali Ganjehlou Damian I. Kachlakev Morris Schupack 
P. N. Balaguru Duane J. Gee Vistasp M. Karbhari David W. Scott 
Craig A. Ballinger T. Russell Gentry Howard S. Kliger Rajan Sen 
Lawrence C. Bank Arie Gerritse James G. Korff Mohsen A. Shahawy 
Abdeldjelil Belarbi Karl Gillette Michael W. Lee Carol K. Shield 
Brahim Benmokrane William J. Gold* Ibrahim Mahfouz Khaled A. Soudki 
Gregg J. Blaszak* Charles H. Goodspeed, III Henry N. Marsh, Jr. Luc R. Taerwe 
Gordon L. Brown, Jr. Nabil F. Grace Orange S. Marshall Jay Thomas 
Vicki L. Brown Mark F. Green Amir Mirmiran Houssam A. Toutanji 
Thomas I. Campbell afzir.Mark E. Greenwood Ayman S. Mosallam Taketo Uomoto 
Charles W. Dolan Doug D. Gremel Antoine E. Naaman Miroslav Vadovic 
Dat Duthinh Michael S. Guglielmo Antonio Nanni David R. Vanderpool 
Rami M. Elhassan Issam E. Harik Kenneth Neale Milan Vatovec 
Salem S. Faza Mark P. Henderson Edward F. O’Neil, III Stephanie L. Walkup 
Edward R. Fyfe Bohdan N. Horeczko Max L. Porter David White 
www.David M. Gale Srinivasa L. Iyer 
ACI Committee Reports, Guides, Standard Practices, 
and Commentaries are intended for guidance in plan-ning, 
designing, executing, and inspecting construction. 
This document is intended for the use of individuals who 
are competent to evaluate the significance and limita-tions 
of its content and recommendations and who will 
accept responsibility for the application of the material 
it contains. The American Concrete Institute disclaims 
any and all responsibility for the stated principles. The 
Institute shall not be liable for any loss or damage arising 
therefrom. 
Reference to this document shall not be made in con-tract 
documents. If items found in this document are de-sired 
ACI 440.2R-02 became effective July 11, 2002. 
by the Architect/Engineer to be a part of the 
Copyright Ó 2002, American Concrete Institute. 
contract documents, they shall be restated in mandatory 
All rights reserved including rights of reproduction and use in any form or by any 
means, including the making of copies by any photo process, or by electronic or 
language for incorporation by the Architect/Engineer. 
mechanical device, printed, written, or oral, or recording for sound or visual reproduction 
or for use in any knowledge or retrieval system or device, unless permission in writing 
is obtained from the copyright proprietors. 
440.2R-1 
ACI 440.2R-02 
Fiber-reinforced polymer (FRP) systems for strengthening concrete structures 
have emerged as an alternative to traditional strengthening techniques, such 
as steel plate bonding, section enlargement, and external post-tensioning. 
FRP strengthening systems use FRP composite materials as supplemental 
externally bonded reinforcement. FRP systems offer advantages over traditional 
strengthening techniques: they are lightweight, relatively easy to install, and 
are noncorrosive. Due to the characteristics of FRP materials, the behavior 
of FRP strengthened members, and various issues regarding the use of 
externally bonded reinforcement, specific guidance on the use of these systems 
is needed. This document offers general information on the history and use of 
FRP strengthening systems; a description of the unique material properties of 
FRP; and committee recommendations on the engineering, construction, and 
inspection of FRP systems used to strengthen concrete structures. The 
proposed guidelines are based on the knowledge gained from worldwide 
experimental research, analytical work, and field applications of FRP 
systems used to strengthen concrete structures. 
Keywords: aramid fibers; bridges; buildings; carbon fibers; concrete; corro-sion; 
crack widths; cracking; cyclic loading; deflections; development length; 
earthquake-resistant; fatigue; fiber-reinforced polymers; flexure; glass fiber; 
shear; stresses; structural analysis; structural design; time-dependent; torsion. 
CONTENTS 
PART 1—GENERAL 
Chapter 1—Introduction, p. 440.2R-2 
1.1—Scope and limitations 
1.2—Applications and use 
1.3—Use of proprietary FRP systems 
1.4—Definitions and acronyms 
1.5—Notation 
Sami H. Rizkalla 
Chair 
John P. Busel 
Secretary 
*Co-chairs of the subcommittee that prepared this document. 
Note: The committee acknowledges the contribution of associate member Paul Kelley.
440.2R-2 ACI COMMITTEE REPORT 
Chapter 2—Background information, p. 440.2R-8 
10.3—com 
Nominal shear strength 
2.1—Historical development 
10.4—FRP system contribution to shear strength 
2.2—Commercially available externally bonded FRP systems 
Chapter 11—Axial compression, tension, and 
PART 2—MATERIALS 
ductility enhancement, p. 440.2R-27 
Chapter 3—Constituent materials and properties, 
11.1—Axial compression 
pp. 440.2R-9 
11.2—Tensile strengthening 
3.1—Constituent materials 
11.3—Ductility 
3.2—Physical properties 
3.3—Mechanical properties and behavior 
Chapter 12—Reinforcement details, p. 440.2R-29 
3.4—Time-dependent behavior 
12.1—Bond and delamination 
3.5—Durability 
12.2—Detailing of laps and splices 
3.6—FRP system qualification 
Chapter 13—Drawings, specifications, and 
PART 3—RECOMMENDED CONSTRUCTION 
submittals, p. 440.2R-30 
REQUIREMENTS 
13.1—Engineering requirements 
Chapter 4—Shipping, storage, and handling, 
pp. 440.2R-12 
13.2—Drawings and specifications 
4.1—Shipping 
13.3—Submittals 
4.2—Storage 
4.3—Handling 
PART 5—DESIGN EXAMPLES 
Chapter 14—Design examples, p. 440.2R-31 
14.1—Calculation of FRP system tensile strength 
Chapter 5—Installation, p. 440.2R-13 
5.1—Contractor competency 
afzir.14.2—Calculation of FRP system tensile strength 
5.2—Temperature, humidity, and moisture considerations 
14.3—Flexural strengthening of an interior beam 
5.3—Equipment 
14.4—Shear strengthening of an interior T-beam 
5.4—Substrate repair and surface preparation 
14.5—Shear strengthening of an exterior column 
5.5—Mixing of resins 
5.6—Application of constituent materials 
Chapter 15—References, p. 440.2R-40 
5.7—Alignment of FRP materials 
15.1—Referenced standards and reports 
5.8—Multiple plies and lap splices 
15.2—Cited references 
5.9—Curing of resins 
15.3—Other references 
5.10—Temporary protection 
www.APPENDIXES 
Chapter 6—Inspection, evaluation, and 
Appendix A—Material properties of carbon, glass, 
acceptance, pp. 440.2R-16 
and aramid fibers, p. 440.2R-44 
6.1—Inspection 
6.2—Evaluation and acceptance 
Appendix B—Summary of standard test methods, 
p. 440.2R-44 
Chapter 7—Maintenance and repair, p. 440.2R-17 
7.1—General 
Appendix C—Areas of future research, p. 440.2R-45 
7.2—Inspection and assessment 
7.3—Repair of strengthening system 
PART 1—GENERAL 
7.4—Repair of surface coating 
CHAPTER 1—INTRODUCTION 
The strengthening or retrofitting of existing concrete 
PART 4—DESIGN RECOMMENDATIONS 
structures to resist higher design loads, correct deterioration-related 
Chapter 8—General design considerations, 
damage, or increase ductility has traditionally been 
p. 440.2R-18 
accomplished using conventional materials and construction 
8.1—Design philosophy 
techniques. Externally bonded steel plates, steel or concrete 
8.2—Strengthening limits 
jackets, and external post-tensioning are just some of the 
8.3—Selection of FRP systems 
many traditional techniques available. 
8.4—Design material properties 
Composite materials made of fibers in a polymeric resin, 
also known as fiber-reinforced polymers (FRP), have 
Chapter 9—Flexural strengthening, p. 440.2R-21 
emerged as an alternative to traditional materials and tech-niques. 
9.1—General considerations 
For the purposes of this document, an FRP system is 
9.2—Nominal strength 
defined as all the fibers and resins used to create the composite 
9.3—Ductility 
laminate, all applicable resins used to bond it to the concrete 
9.4—Serviceability 
substrate, and all applied coatings used to protect the constituent 
9.5—Creep-rupture and fatigue stress limits 
materials. Coatings used exclusively for aesthetic reasons are 
9.6—Application to a singly reinforced rectangular section 
not considered part of an FRP system. 
FRP materials are lightweight, noncorrosive, and exhibit 
Chapter 10—Shear strengthening, pp. 440.2R-25 
high tensile strength. Additionally, these materials are readily 
10.1—General considerations 
available in several forms ranging from factory-made laminates 
10.2—Wrapping schemes 
to dry fiber sheets that can be wrapped to conform to the
DESIGN AND CONSTRUCTION OF EXTERNALLY BONDED FRP SYSTEMS 440.2R-3 
geometry of a structure before adding the polymer resin. 
resins, or fiber/resin combinations for which this is not true. 
The relatively thin profile of cured FRP systems are often 
This document com 
currently does not have special provisions for 
desirable in applications where aesthetics or access is a concern. 
such materials. 
The growing interest in FRP systems for strengthening and 
Many issues regarding bond of the FRP system to the 
retrofitting can be attributed to many factors. Although the 
substrate remain the focus of a great deal of research. For 
fibers and resins used in FRP systems are relatively expensive 
both flexural and shear strengthening, there are many different 
compared to traditional strengthening materials like concrete 
varieties of debonding failure that can govern the strength of 
and steel, labor and equipment costs to install FRP systems 
an FRP-strengthened member. While most of the debonding 
are often lower. FRP systems can also be used in areas 
modes have been identified by researchers, more accurate 
with limited access where traditional techniques would 
methods of predicting debonding are still needed. Throughout 
be difficult to implement: for example, a slab shielded by 
pipe and conduit. 
the design procedures, significant limitations on the strain level 
The basis for this document is the knowledge gained from 
achieved in the FRP material (and thus the stress level 
worldwide experimental research, applications of FRP strengthening in this document are intended Areas where further research is needed this document and compiled in Appendix 1.1—Scope and limitations 
This document provides guidance and installation of FRP systems for concrete structures. Information afzir.analytical work, and field 
achieved) are imposed to conservatively account for debonding 
systems. The recommen-dations 
failure modes. It is envisioned that future development of 
to be conservative. 
these design procedures will include more thorough methods 
are highlighted in 
of predicting debonding. 
C. 
The document does give guidance on proper detailing and 
installation of FRP systems to prevent many types of debonding 
failure modes. Steps related to the surface preparation and 
for the selection, design, 
proper termination of the FRP system are vital in achieving 
externally strengthening 
the levels of strength predicted by the procedures in this 
on material properties, 
document. Some research has been conducted on various 
design, installation, quality control, and maintenance of FRP 
methods of anchoring FRP strengthening systems (by 
systems used as external reinforcement is presented. This 
mechanical or other means). It is important to recognize, 
information can be used to select an FRP system for increasing 
however, that methods of anchoring these systems are 
the strength and stiffness of reinforced concrete beams or the 
highly problematic due to the brittle, anisotropic nature 
ductility of columns, and other applications. 
of composite materials. Any proposed method of anchorage 
A significant body of research serves as the basis for this 
should be heavily scrutinized before field implementation. 
document. This research, conducted over the past 20 years, 
The design equations given in this document are the result of 
includes analytical studies, experimental work, and monitored 
research primarily conducted on moderately sized and 
field applications of FRP strengthening systems. Based on 
the available research, the design procedures outlined in this 
proportioned members. While FRP systems likely are effective 
www.document are considered to be conservative. It is important 
on other members, such as deep beams, this has not been 
to note, however, that the design procedures have not, in 
validated through testing. Caution should be given to applica-tions 
many cases, been thoroughly developed and proven. It is 
involving strengthening of very large members or 
envisioned that over time these procedures will be adapted to 
strengthening in disturbed regions (D-regions) of structural 
be more accurate. For the time being, it is important to 
members. Where warranted, specific limitations on the size of 
specifically point out the areas of the document that do still 
members to be strengthened are given in this document. 
require research. 
This document applies only to FRP strengthening systems 
The durability and long-term performance of FRP materials 
used as additional tensile reinforcement. It is currently not 
have been the subject of much research; however, this research 
recommended to use these systems as compressive reinforce-ment. 
remains ongoing. Long-term field data are not currently 
While FRP materials can support compressive stresses, 
available, and it is still difficult to accurately predict the life 
there are numerous issues surrounding the use of FRP for 
of FRP strengthening systems. The design guidelines in this 
compression. Microbuckling of fibers can occur if any resin 
document do account for environmental degradation and 
voids are present in the laminate, laminates themselves can 
long-term durability by suggesting reduction factors for 
buckle if not properly adhered or anchored to the substrate, 
various environments. Long-term fatigue and creep are 
and highly unreliable compressive strengths result from 
also addressed by stress limitations indicated in this document. 
misaligning fibers in the field. This document does not address 
These factors and limitations are considered to be conservative. 
the construction, quality control, and maintenance issues that 
As more research becomes available, however, these factors 
would be involved with the use of the material for this purpose, 
will be modified and the specific environmental conditions 
nor does it address the design concerns surrounding such 
and loading conditions to which they should apply will be better 
defined. Additionally, the coupling effect of environmen-tal 
applications. The use of the types of FRP strengthening 
conditions and loading conditions still requires further 
systems described in this document to resist compressive 
study. Caution is advised in applications where the FRP 
forces is strongly discouraged. 
system is subjected simultaneously to extreme environmental 
This document does not specifically address masonry 
and stress conditions. 
(concrete masonry units, brick, or clay tile) construction, 
The factors associated with the long-term durability of the 
including masonry walls. Research completed to date, 
FRP system do not affect the tensile modulus of the material 
however, has shown that FRP systems can be used to 
used for design. Generally, this is reasonable given that the 
strengthen masonry walls, and many of the guidelines contained 
tensile modulus of FRP materials is not affected by environ-mental 
in this document may be applicable (Triantafillou 1998b; 
conditions. There may be, however, specific fibers, 
Ehsani et al. 1997; and Marshall et al. 1999).
440.2R-4 ACI COMMITTEE REPORT 
1.2—Applications and use 
Due to the low temperature resistance of most fiber-rein-forced 
FRP systems can be used to rehabilitate or restore the 
polymer materials, the strength of externally bonded 
strength of a deteriorated structural member, to retrofit or 
FRP systems is assumed to be lost completely in a fire. For 
strengthen a sound structural member to resist increased 
this reason, the structural member without the FRP system 
loads due to changes in use of the structure, or to address 
should com 
possess sufficient strength to resist all applicable 
design or construction errors. The engineer should determine 
loads during a fire. Specific guidance, including load 
if an FRP system is a suitable strengthening technique before 
combinations and a rational approach to calculating structural 
selecting the type of FRP system. 
fire endurance, is given in Part 4. 
To assess the suitability of an FRP system for a particular 
The fire endurance of FRP-strengthened concrete members 
application, the engineer should perform a condition assessment 
may be improved through the use of certain resins, coatings, 
of the existing structure including establishing its existing 
or other methods of fire protection, but these have not been 
load-carrying capacity, identifying deficiencies and their 
sufficiently demonstrated to insulate the FRP system from 
causes, and determining the condition of the concrete 
the temperatures reached during a fire. 
substrate. The overall evaluation field inspection, a review of documents, and a structural analysis ACI 364.1R. Existing construction afzir.should include a thorough 
1.2.3 Maximum service temperature—The physical and 
existing design or as-built 
mechanical properties of the resin components of FRP systems 
in accordance with 
are influenced by temperature and degrade above their glass-transition 
documents for the 
temperature Tg. The Tg is the midpoint of the 
structure should be reviewed, including the design drawings, 
temperature range over which the resin changes from a 
project specifications, as-built information, field test reports, past 
hard brittle state to a softer plastic state. This change in 
repair documentation, and maintenance history documentation. 
state will degrade the properties of the cured laminates. 
The engineer should conduct a thorough field investigation of 
The Tg is unique to each FRP system and ranges from 140 
the existing structure in accordance with ACI 437R or other 
to 180 F (60 to 82 C) for existing, commercially available 
applicable documents. The tensile strength of the concrete on 
FRP systems. The maximum service temperature of an 
surfaces where the FRP system may be installed should be 
FRP system should not exceed the Tg of the FRP system. 
evaluated by conducting a pull-off adhesion test in accordance 
The Tg for a particular FRP system can be obtained from 
with ACI 503R. In addition, field investigation should verify 
the system manufacturer. 
the following: 
1.2.4 Minimum concrete substrate strength—FRP systems 
• Existing dimensions of the structural members; 
work on sound concrete and should not be considered for 
• Location, size, and cause of cracks and spalls; 
applications on structural members containing corroded 
• Location and extent of corrosion of reinforcing steel; 
reinforcing steel or deteriorated concrete unless the substrate is 
• Quantity and location of existing reinforcing steel; 
repaired in accordance with Section 5.4. Concrete distress, 
• In-place compressive strength of concrete; and 
deterioration, and corrosion of existing reinforcing steel 
www.• Soundness of the concrete, especially the concrete 
should be evaluated and addressed before the application of 
cover, in all areas where the FRP system is to be 
the FRP system. Concrete deterioration concerns include, 
bonded to the concrete. 
but are not limited to, alkali-silica reactions, delayed 
The load-carrying capacity of the existing structure should 
ettringite formation, carbonation, longitudinal cracking 
be based on the information gathered in the field investigation, 
around corroded reinforcing steel, and laminar cracking at 
the review of design calculations and drawings, and as 
the location of the steel reinforcement. 
determined by analytical or other suitable methods. Load 
The condition and strength of the substrate should be 
tests or other methods can be incorporated into the overall 
evaluated to determine its capacity for strengthening of the 
evaluation process if deemed appropriate. 
member with externally bonded FRP reinforcement. The 
The engineer should survey the available literature and 
bond between repair materials and original concrete should 
consult with FRP system manufacturers to ensure the selected 
satisfy the recommendations of ACI 503R or Section 3.1 of 
FRP system and protective coating are appropriate for the 
ICRI Guideline No. 03733. 
intended application. 
The existing concrete substrate strength is an important 
1.2.1 Strengthening limits—Some engineers and system 
parameter for bond-critical applications, including flexure or 
manufacturers have recommended that the increase in the 
shear strengthening. It should possess the necessary strength 
load-carrying capacity of a member strengthened with an 
to develop the design stresses of the FRP system through 
FRP system be limited. The philosophy is that a loss of FRP 
bond. The substrate, including all bond surfaces between 
reinforcement should not cause member failure. Specific 
repaired areas and the original concrete, should have sufficient 
guidance, including load combinations for assessing member 
direct tensile and shear strength to transfer force to the FRP 
integrity after loss of the FRP system, is provided in Part 4. 
system. The tensile strength should be at least 200 psi (1.4 MPa) 
FRP systems used to increase the strength of an existing 
as determined by using a pull-off type adhesion test as in 
member should be designed in accordance with Part 4, which 
ACI 503R or ASTM D 4541. FRP systems should not be used 
includes a comprehensive discussion of load limitations, 
when the concrete substrate has a compressive strength ( fc¢ ) 
sound load paths, effects of temperature and environment on 
less than 2500 psi (17 MPa). Contact-critical applications, 
FRP systems, loading considerations, and effects of reinforcing 
such as column wrapping for confinement that rely only on 
steel corrosion on FRP system integrity. 
intimate contact between the FRP system and the concrete, are 
1.2.2 Fire and life safety—FRP-strengthened structures 
not governed by this minimum value. Design stresses in the 
should comply with all applicable building and fire codes. 
FRP system are developed by deformation or dilation of the 
Smoke and flame spread ratings should be determined in 
concrete section in contact-critical applications. 
accordance with ASTM E 84. Coatings can be used to limit 
The application of FRP systems will not stop the ongoing 
smoke and flame spread. 
corrosion of existing reinforcing steel. If steel corrosion is
DESIGN AND CONSTRUCTION OF EXTERNALLY BONDED FRP SYSTEMS 440.2R-5 
evident or is degrading the concrete substrate, placement 
concrete com 
substrate and the FRP system. In general, contact-critical 
of FRP reinforcement is not recommended without arresting the 
applications consist of FRP systems that completely 
ongoing corrosion and repairing any degradation to the substrate. 
wrap around the perimeter of the section. For most contact-critical 
applications the FRP system is bonded to the concrete 
1.3—Use of proprietary FRP systems 
to facilitate installation but does not rely on that bond to perform 
This document refers specifically to commercially 
as intended. Confinement of columns for seismic retrofit is an 
available, proprietary FRP systems consisting of fibers 
example of a contact-critical application. 
and resins combined in a specific manner and installed by 
Creep-rupture—The gradual, time-dependent reduction 
a specific method. These systems have been developed 
of tensile strength due to continuous loading that leads to 
through material characterization and structural testing. 
failure of the section. 
Untested combinations of fibers and resins could result in 
Cross-link—A chemical bond between polymer molecules. 
an unexpected range of properties as well as potential 
Note: an increased number of cross-links per polymer 
material incompatibilities. Any FRP system considered 
molecule increases strength and modulus at the expense 
for use should have sufficient test data demonstrating adequate 
of ductility. 
performance of the entire system afzir.in similar applications, 
Cure of FRP systems—The process of causing the irre-versible 
including its method of installation. 
change in the properties of a thermosetting resin by 
The use of FRP systems developed through material 
chemical reaction. Cure is typically accomplished by addition 
characterization and structural testing, including well-documented 
of curing (cross-linking) agents or initiators, with or without 
proprietary systems, is recommended. The 
heat and pressure. Full cure is the point at which a resin 
use of untested combinations of fibers and resins should be 
reaches the specified properties. Undercure is a condition 
avoided. A comprehensive set of test standards for FRP 
where specified properties have not been reached. 
systems is being developed by several organizations, including 
Curing agent—A catalytic or reactive agent that causes 
ASTM, ACI, ICRI, and the Intelligent Sensing for Innovative 
polymerization when added to a resin. Also called hardener 
Structures organization (ISIS). Available standards from these 
or initiator. 
organizations are outlined in Appendix B. 
Debonding—A separation at the interface between the 
substrate and the adherent material. 
1.4—Definitions and acronyms 
Degradation—A decline in the quality of the mechanical 
The following definitions clarify terms pertaining to FRP 
properties of a material. 
that are not commonly used in the reinforced concrete practice. 
Delamination—A separation along a plane parallel to the 
These definitions are specific to this document and are not 
surface, as in the separation of the layers of the FRP laminate 
applicable to other ACI documents. 
from each other. 
AFRP—Aramid fiber-reinforced polymer. 
www.Batch—Quantity of material mixed at one time or in one 
Development length, FRP—The bonded distance required 
continuous process. 
for transfer of stresses from the concrete to the FRP so as to 
Binder—develop the strength of the FRP system. The development 
Chemical treatment applied to the random arrange-ment 
length is a function of the strength of the substrate and the 
of fibers to give integrity to mats, roving, and fabric. 
rigidity of the bonded FRP. 
Specific binders are utilized to promote chemical compatibility 
with the various laminating resins used. 
Durability, FRP—The ability of a material to resist 
Bond-critical applications—Applications of FRP systems 
weathering action, chemical attack, abrasion, and other 
for strengthening structural members that rely on bond to the 
conditions of service. 
concrete substrate; flexural and shear strengthening of 
E-glass—A family of glass with a calcium alumina 
beams and slabs are examples of bond-critical applications. 
borosilicate composition and a maximum alkali content of 
Catalyst—A substance that accelerates a chemical reaction 
2.0%. A general-purpose fiber that is used in reinforced 
and enables it to proceed under conditions more mild than 
polymers. 
otherwise required and that is not, itself, permanently 
Epoxy—A thermosetting polymer that is the reaction product 
changed by the reaction. See Initiator or Hardener. 
of epoxy resin and an amino hardener. (See also Epoxy resin.) 
CFR—Code of Federal Regulations. 
Epoxy resin—A class of organic chemical-bonding systems 
CFRP—Carbon fiber-reinforced polymer (includes graphite 
used in the preparation of special coatings or adhesives for 
fiber-reinforced polymer). 
concrete as binders in epoxy-resin mortars and concretes. 
Composite—A combination of two or more constituent 
Fabric—Arrangement of fibers held together in two 
materials differing in form or composition on a macroscale. 
dimensions. A fabric can be woven, nonwoven, knitted, or 
Note: The constituents retain their identities; that is, they do 
stitched. Multiple layers of fabric may be stitched together. 
not dissolve or merge completely into one another, although 
Fabric architecture is the specific description of fibers, 
they act in concert. Normally, the components can be physically 
directions, and construction of the fabric. 
identified and exhibit an interface between one another. 
Fiber—Any fine thread-like natural or synthetic object of 
Concrete substrate—The existing concrete or any cemen-titious 
mineral or organic origin. Note: This term is generally used 
repair materials used to repair or replace the existing 
for materials whose length is at least 100 times its diameter. 
concrete. The substrate can consist entirely of existing concrete, 
Fiber, aramid—Highly oriented organic fiber derived 
entirely of repair materials, or of a combination of existing 
from polyamide incorporating into an aromatic ring structure. 
concrete and repair materials. The substrate includes the surface 
Fiber, carbon—Fiber produced by heating organic 
to which the FRP system is installed. 
precursor materials containing a substantial amount of 
Contact-critical applications—Applications of FRP 
carbon, such as rayon, polyacrylonitrile (PAN), or pitch 
systems that rely on continuous intimate contact between the 
in an inert environment.
440.2R-6 ACI COMMITTEE REPORT 
Fiber, glass—Fiber drawn from an inorganic product of 
Interlaminar shear—Shearing force tending to produce a 
fusion that has cooled without crystallizing. Types of glass 
relative displacement between two laminae in a laminate 
fibers include alkali resistant (AR-glass), general purpose 
along the plane of their interface. 
(E-glass), and high strength (S-glass). 
Laminate—One or more layers of fiber bound together in 
Fiber content—The amount of fiber present in a composite. 
a cured resin matrix. 
Note: This usually is expressed as a percentage volume fraction 
Layup—The process of placing the FRP reinforcing 
or weight fraction of the composite. 
material com 
in position for molding. 
Fiber fly—Short filaments that break off dry fiber tows or 
Mat—A fibrous material for reinforced polymer, consisting 
yarns during handling and become airborne; usually classified 
of randomly oriented chopped filaments, short fibers (with 
as a nuisance dust. 
or without a carrier fabric), or long random filaments loosely 
Fiberglass—A composite material consisting of glass fibers 
held together with a binder. 
in resin. 
Matrix—In the case of fiber-reinforced polymers, the 
Fiber-reinforced polymer (FRP)—A general term for a 
materials that serve to bind the fibers together, transfer load 
composite material that consists of a polymer matrix reinforced 
to the fibers, and protect them against environmental attack 
with cloth, mat, strands, or any other fiber form. See 
and damage due to handling. 
Composite. 
Monomer—An organic molecule of relatively low 
Fiber volume fraction—The afzir.ratio of the volume of fibers 
molecular weight that creates a solid polymer by reacting 
to the volume of the composite. 
with itself or other compounds of low molecular weight or both. 
Fiber weight fraction—The ratio of the weight of fibers 
MSDS—Material safety data sheet. 
to the weight of the composite. 
OSHA—Occupational Safety and Health Administration. 
Filament—See Fiber. 
PAN—Polyacrylonitrile, a precursor fiber used to make 
Filler—A relatively inert substance added to a resin to 
carbon fiber. 
alter its properties or to lower cost or density. Sometimes the 
Phenolic—A thermosetting resin produced by the condensa-tion 
term is used specifically to mean particulate additives. Also 
of an aromatic alcohol with an aldehyde, particularly of 
called extenders. 
phenol with formaldehyde. 
Fire retardant—Chemicals that are used to reduce the 
Pitch—Petroleum or coal tar precursor base used to make 
tendency of a resin to burn; these can be added to the resin or 
carbon fiber. 
coated on the surface of the FRP. 
Ply—A single layer of fabric or mat; multiple plies, when 
Flow—molded together, make up the laminate. 
The movement of uncured resin under pressure or 
Polyester—gravity loads. 
One of a large group of synthetic resins, mainly 
produced by the reaction of dibasic acids with dihydroxy 
FRP—Fiber reinforced polymer; formerly, fiber-reinforced 
alcohols; commonly prepared for application by mixing with 
plastic. 
www.a vinyl-group monomer and free-radical catalysts at ambient 
GFRP—Glass fiber-reinforced polymer. 
temperatures and used as binders for resin mortars and 
Glass fiber—An individual filament made by drawing or 
concretes, fiber laminates (mainly glass), adhesives, and the 
spinning molten glass through a fine orifice. A continuous 
like. Commonly referred to as “unsaturated polyester.” 
filament is a single glass fiber of great or indefinite length. A 
Polymer—A high molecular weight organic compound, 
staple fiber is a glass fiber of relatively short length, generally 
natural or synthetic, containing repeating units. 
less than 17 in. (0.43 m), the length related to the forming or 
Polymerization—The reaction in which two or more 
spinning process used. 
molecules of the same substance combine to form a compound 
Glass transition temperature (Tg)—The midpoint of the 
containing the same elements and in the same proportions but 
temperature range over which an amphoras material (such as 
of higher molecular weight. 
glass or a high polymer) changes from (or to) a brittle, vitreous 
Polyurethane—Reaction product of an isocyanate with 
state to (or from) a plastic state. 
any of a wide variety of other compounds containing an 
Grid, FRP—A two-dimensional (planar) or three-dimen-sional 
active hydrogen group; used to formulate tough, abrasion-resistant 
(spatial) rigid array of interconnected FRP bars that 
coatings. 
form a contiguous lattice that can be used to reinforce concrete. 
Postcuring, FRP—Additional elevated-temperature curing 
The lattice can be manufactured with integrally connected bars 
that increases the level of polymer cross-linking; final properties 
or made of mechanically connected individual bars. 
of the laminate or polymer are enhanced. 
Hardener—1) a chemical (including certain fluosilicates or 
Pot life—Time interval after preparation during which a 
sodium silicate) applied to concrete floors to reduce wear and 
liquid or plastic mixture is to be used. 
dusting; or 2) in a two-component adhesive or coating, the 
Prepreg—A fiber or fiber sheet material containing resin 
chemical component that causes the resin component to cure. 
that is advanced to a tacky consistency. Multiple plies of 
Impregnate—In fiber-reinforced polymers, to saturate 
prepreg are typically cured with applied heat and pressure; 
the fibers with resin. 
also preimpregnated fiber or sheet. 
Initiator—A source of free radicals, which are groups of 
Pultrusion—A continuous process for manufacturing 
atoms that have at least one unpaired electron, used to start 
composites that have a uniform cross-sectional shape. The 
the curing process for unsaturated polyester and vinyl ester 
process consists of pulling a fiber-reinforcing material 
resins. Peroxides are the most common source of free radicals. 
through a resin impregnation bath then through a shaping die 
See Catalyst. 
where the resin is subsequently cured. 
Interface—The boundary or surface between two different, 
Resin—Polymeric material that is rigid or semirigid at 
physically distinguishable media. On fibers, the contact area 
room temperature, usually with a melting point or glass 
between fibers and coating/sizing. 
transition temperature above room temperature.
DESIGN u u * 
* 
AND CONSTRUCTION OF EXTERNALLY BONDED FRP SYSTEMS 440.2R-7 
Resin content—The amount of resin in a laminate, expressed 
CE = environmental-reduction factor 
as either a percentage of total mass or total volume. 
d = distance from extreme compression fiber to the 
Roving—A number of yarns, strands, tows, or ends of 
neutral axis, in. (mm) 
fibers collected into a parallel bundle with little or no twist. 
df = com 
depth of FRP shear reinforcement as shown in 
Sheet, FRP—A dry, flexible ply used in wet layup FRP 
Fig. 10.2, in. (mm) 
systems. Unidirectional FRP sheets consist of continuous 
fibers aligned in one direction and held together in-plane to 
Ec = modulus of elasticity of concrete, psi (MPa) 
create a ply of finite width and length. Fabrics are also referred 
Ef = tensile modulus of elasticity of FRP, psi (MPa) 
to as sheets. See Fabric, Ply. 
Es = modulus of elasticity of steel, psi (MPa) 
Shelf life—The length of time packaged materials can be 
fc = compressive stress in concrete, psi (MPa) 
stored under specified conditions and remain usable. 
fc¢ = specified compressive strength of concrete, psi (MPa) 
Sizing—Surface treatment or coating applied to filaments 
Öfc¢ = square root of specified compressive strength of 
to improve the filament-to-resin bond and to impart processing 
concrete 
and durability attributes. 
afzir.fc= apparent compressive strength of confined concrete, 
Sustained stress—Stress caused by unfactored sustained 
psi (MPa) 
loads including dead loads and the sustained portion of the 
live load. 
ff = stress level in the FRP reinforcement, psi (MPa) 
Thermoset—Resin that is formed by cross-linking polymer 
ff,s = stress level in the FRP caused by a moment within 
chains. Note: A thermoset cannot be melted and recycled 
the elastic range of the member, psi (MPa) 
because the polymer chains form a three-dimensional network. 
ffe = effective stress in the FRP; stress level attained at 
Tow—An untwisted bundle of continuous filaments. 
section failure, psi (MPa) 
Vinyl ester—A thermosetting resin containing both vinyl 
ffu 
* = ultimate tensile strength of the FRP material as 
and ester components, and cured by additional polymerization 
reported by the manufacturer, psi (MPa) 
initiated by free-radical generation. Vinyl esters are used as 
ffu = design ultimate tensile strength of FRP, psi 
binders for fiber laminates and adhesives. 
(MPa) 
VOC—Volatile organic compounds; any compound of 
carbon, excluding carbon monoxide, carbon dioxide, carbonic 
ffu 
= mean ultimate strength of FRP based on a popu-lation 
acid, metallic carbides, or carbonates, and ammonium 
of 20 or more tensile tests per ASTM D 
carbonate, that participates in atmospheric photochemical 
3039, psi (MPa) 
reactions, such as ozone depletion. 
fl = confining pressure due to FRP jacket, psi (MPa) 
Volume fraction—The proportion from 0.0 to 1.0 of a 
fs = stress in nonprestressed steel reinforcement, psi 
component within the composite, measured on a volume 
(MPa) 
www.basis, such as fiber-volume fraction. 
fs,s = stress level in nonprestressed steel reinforcement at 
Wet layup—A method of making a laminate product by 
service loads, psi (MPa) 
applying the resin system as a liquid when the fabric or mat 
fy = specified yield strength of nonprestressed steel 
is put in place. 
reinforcement, psi (MPa) 
Wet-out—The process of coating or impregnating roving, 
yarn, or fabric in which all voids between the strands and 
h = overall thickness of a member, in. (mm) 
filaments are filled with resin; it is also the condition at 
Icr = moment of inertia of cracked section transformed to 
which this state is achieved. 
concrete, in.4 (mm4) 
Witness panel—A small field sample FRP panel, manufac-tured 
k = ratio of the depth of the neutral axis to the reinforce-ment 
on-site in a noncritical area at conditions similar to the 
depth measured on the same side of neutral 
actual construction. The panel can be later tested to determine 
axis 
mechanical and physical properties to confirm expected 
kf = stiffness per unit width per ply of the FRP rein-forcement, 
properties of the installed FRP laminate. 
lb/in. (N/mm); kf = Ef tf 
Yarn—An assemblage of twisted filaments, fibers, or 
k1 = modification factor applied to kv to account for the 
strands, formed into a continuous length that is suitable for 
use in weaving textile materials. 
concrete strength 
k2 = modification factor applied to kv to account for the 
1.5—Notation 
wrapping scheme 
Af = ntfwf , area of FRP external reinforcement, in.2 
Le = active bond length of FRP laminate, in. (mm) 
(mm2) 
ldf = development length of FRP system, in. (mm) 
Afv = area of FRP shear reinforcement with spacing s, in.2 
Mcr = cracking moment, in.-lb (N-mm) 
(mm2) 
Mn = nominal moment strength, in.-lb (N-mm) 
Ag = gross area of section, in.2 (mm2) 
Ms = moment within the elastic range of the member, 
As = area of nonprestressed steel reinforcement, in.2 
in.-lb (N-mm) 
(mm2) 
Mu = factored moment at section, in.-lb (N-mm) 
Ast = total area of longitudinal reinforcement, in.2 (mm2) 
n = number of plies of FRP reinforcement 
b = width of rectangular cross section, in. (mm) 
pf= ultimate tensile strength per unit width per play of 
bw = web width or diameter of circular section, in. (mm) 
the FRP reinforcement, lb/in. (N/mm); pf=fftf 
c = distance from extreme compression fiber to the 
pfu 
= mean tensile strength per unit width per ply u * 
of the 
neutral axis, in. (mm) 
c reinforcement, lb/in. (N/¢ 
mm)
440.2R-u * 
8 ACI COMMITTEE REPORT 
Pn = nominal axial load strength at given eccentricity, lb 
km = bond-dependent coefficient for flexure 
(N) 
kv = bond-dependent coefficient for shear 
r = radius of the edges of a square or rectangular section 
rf = FRP reinforcement ratio 
confined with FRP, in. (mm) 
rg = ratio of the area of longitudinal steel reinforcement to 
Rn = nominal strength of a member 
the cross-sectional area of a compression member 
Rnf = nominal strength of a member subjected to the 
rs = ratio of nonprestressed reinforcement 
elevated temperatures associated with a fire 
s = standard deviation 
SDL = dead load effects 
yf = com 
additional FRP strength-reduction factor 
sf = spacing FRP shear reinforcing as described in 
Fig. 10.2, in. (mm) 
CHAPTER 2—BACKGROUND INFORMATION 
SLL = live load effects 
Externally bonded FRP systems have been used to 
tf = nominal thickness of one ply of the FRP reinforce-ment, 
strengthen and retrofit existing concrete structures around 
in. (mm) 
afzir.the world since the mid 1980s. The number of projects 
Tg = glass-transition temperature, °F (°C) 
utilizing FRP systems worldwide has increased dramatically, 
Vc = nominal shear strength provided by concrete with 
from a few 10 years ago to several thousand today (Bakis et 
steel flexural reinforcement, lb (N) 
al. 2002). Structural elements strengthened with externally 
Vn = nominal shear strength, lb (N) 
bonded FRP systems include beams, slabs, columns, walls, 
Vs = nominal shear strength provided by steel stirrups, 
joints/connections, chimneys and smokestacks, vaults, 
domes, tunnels, silos, pipes, and trusses. Externally bonded 
lb (N) 
FRP systems have also been used to strengthen masonry, 
Vf = nominal shear strength provided by FRP stirrups, lb 
timber, steel, and cast-iron structures. The idea of strengthening 
wf = width of the FRP reinforcing plies, in. (mm) 
concrete structures with externally bonded reinforcement is not 
a = angle of inclination of stirrups or spirals, degrees 
new. Externally bonded FRP systems were developed as 
aL = longitudinal coefficient of thermal expansion, in./in./ 
alternates to traditional external reinforcing techniques like 
°F (mm/mm/°C) 
steel plate bonding and steel or concrete column jacketing. 
a= transverse coefficient of thermal expansion, in./in./°F 
The initial development of externally bonded FRP systems 
T (mm/mm/°C) 
for the retrofit of concrete structures occurred in the 1980s in 
bboth Europe and Japan. 
1 = ratio of the depth of the equivalent rectangular stress 
block to the depth of the neutral axis 
e= strain level in the concrete substrate developed by a 
2.1—Historical development 
b given bending moment (tension in positive), in./in. 
In Europe, FRP systems were developed as alternates to 
www.steel plate bonding. Bonding steel plates to the tension zones 
(mm/mm) 
of concrete members with epoxy resins were shown to be 
ebi = strain level in the concrete substrate at the time of the 
viable techniques for increasing their flexural strengths 
FRP installation (tension is positive), in./in. (mm/mm) 
(Fleming and King 1967). This technique has been used to 
ec = stain level in the concrete, in./in. (mm/mm) 
strengthen many bridges and buildings around the world. 
ec= maximum usable compressive strain of FRP confined 
Because steel plates can corrode, leading to a deterioration of 
concrete, in./in. (mm/mm) 
the bond between the steel and concrete, and that are difficult 
e= maximum usable compressive strain of concrete, in./ 
to install, requiring the use of heavy equipment, researchers 
cu in., (mm/mm) 
have looked to FRP materials as an alternative to steel. 
ef = strain level in the FRP reinforcement, in./in. (mm/ 
Experimental work using FRP materials for retrofitting 
mm) 
concrete structures was reported as early as 1978 in Germany 
e(Wolf and Miessler 1989). Research in Switzerland led to 
fe = effective strain level in FRP reinforcement; strain level 
the first applications of externally bonded FRP systems 
attained at section failure, in./in. (mm/mm) 
to reinforced concrete bridges for flexural strengthening 
efu = design rupture strain of FRP reinforcement, in./in. 
(Meier 1987; Rostasy 1987). 
(mm/mm) 
FRP systems were first applied to reinforced concrete 
efu = mean rupture stain of FRP reinforcement based on 
columns for providing additional confinement in Japan in 
a population of 20 or more tensile tests per 
the 1980s (Fardis and Khalili 1981; Katsumata et al. 1987). 
ASTM D 3039, in./in. (mm/mm) 
A sudden increase in the use of FRPs in Japan was observed 
eafter the 1995 Hyogoken Nanbu earthquake (Nanni 1995). 
f= ultimate rupture strain of the FRP reinforcement, 
in./in. (mm/mm) 
The United States has had a long and continuous interest 
es = strain level in the nonprestessed steel reinforcement, 
in fiber-based reinforcement for concrete structures since the 
in./in./ (mm) 
1930s. Actual development and research into the use of these 
esy = strain corresponding to the yield strength of non-prestressed 
materials for retrofitting concrete structures, however, started 
in the 1980s through the initiatives of the National Science 
steel reinforcement 
Foundation (NSF) and the Federal Highway Administration 
f = strength reduction factor 
(FHWA). The research activities led to the construction of 
g = multiplier on fc¢ to determine the intensity of an 
many field projects encompassing a wide variety of environ-mental 
equivalent rectangular stress distribution for concrete 
conditions. Previous research and field applications 
ka = efficiency factor for FRP reinforcement (based on 
for FRP rehabilitation and strengthening are described in 
the section geometry) 
ACI 440R-96 and conference proceedings (Japan Concrete 
c ¢
DESIGN AND CONSTRUCTION OF EXTERNALLY BONDED FRP SYSTEMS 440.2R-9 
Institute 1997; Neale 2000; Dolan et al. 1999; Sheheta et al. 
1. Preimpregnated 1999; Saadatmanesh and Ehsani 1998; Benmokrane and 
run predominantly Rahman 1998; Neale and Labossière 1997; Hassan and 
2. Preimpregnated Rizkalla 2002). 
where the The development of codes and standards for externally 
and 
bonded FRP systems is ongoing in Europe, Japan, Canada, 
3. Preimpregnated and the United States. Within the last 10 years, the Japan 
mechanically com 
unidirectional fiber sheets where the fibers 
in one planar direction; 
multidirectional fiber sheets or fabrics 
fibers are oriented in at least two planar directions; 
fiber tows that are wound or otherwise 
applied to the concrete surface. 
Society of Civil Engineers (JSCE) and the Japan Concrete 
2.2.3 Precured systems—Precured FRP systems consist of 
Institute (JCI) and the Railway Technical Research Institute 
a wide variety of composite shapes manufactured off-site. 
(RTRI) published several documents related to the use of 
Typically, an adhesive along with the primer and putty is 
FRP materials in concrete structures. 
used to bond the precured shapes to the concrete surface. The 
In Europe, Task Group 9.3 of the International Federation 
system manufacturer should be consulted for recommended 
for Structural Concrete (FIB) recently published a bulletin 
installation procedures. Precured systems are analogous to 
on design guidelines for externally for reinforced concrete structures The Canada Standards Association afzir.bonded FRP reinforcement 
precast concrete. Three common types of precured systems 
(FIB 2001). 
are listed as follows: 
and ISIS have been 
1. Precured unidirectional laminate sheets, typically delivered 
active in developing guidelines for FRP systems. Section 16, 
to the site in the form of large flat stock or as thin ribbon 
“Fiber Reinforced Concrete,” of the Canadian Highway 
strips coiled on a roll; 
Bridge Design Code was completed in 2000 (CSA S806-02) 
2. Precured multidirectional grids, typically delivered to 
and the Canadian Standards Association (CSA) recently 
the site coiled on a roll; 
approved the code “Design and Construction of Building 
3. Precured shells, typically delivered to the site in the 
Components with Fiber Reinforced Polymers” (CSA S806-02). 
form of shell segments cut longitudinally so they can be 
In the United States, criteria for evaluating FRP systems 
opened and fitted around columns or other members; multiple 
are becoming available to the construction industry (AC125 
shell layers are bonded to the concrete and to each other to 
1997; CALTRANS 1996; Hawkins et al. 1998). 
provide seismic confinement. 
2.2.4 Other FRP forms—Other FRP forms are not covered 
2.2—Commercially available externally bonded 
in this document. These include cured FRP rigid rod and 
FRP systems 
flexible strand or cable (Saadatmanesh and Tannous 
FRP systems come in a variety of forms, including wet 
1999a; Dolan 1999; Fukuyama 1999; ACI 440R-96 and 
layup systems and precured systems. FRP system forms can 
ACI 440.1R-01). 
be categorized based on how they are delivered to the site 
and installed. The FRP system and its form should be selected 
PART 2—MATERIALS 
www.based on the acceptable transfer of structural loads and the 
CHAPTER 3—CONSTITUENT MATERIALS AND 
ease and simplicity of application. Common FRP system 
PROPERTIES 
forms suitable for the strengthening of structural members are 
The physical and mechanical properties of FRP materials 
listed as follows: 
presented in this chapter explain the behavior and properties 
2.2.1 Wet layup systems—Wet layup FRP systems consist 
affecting their use in concrete structures. The effects of factors 
of dry unidirectional or multidirectional fiber sheets or fabrics 
such as loading history and duration, temperature, and moisture 
impregnated with a saturating resin on-site. The saturating 
on the properties of FRP are discussed. 
resin, along with the compatible primer and putty, is used to 
FRP-strengthening systems come in a variety of forms 
bond the FRP sheets to the concrete surface. Wet layup sys-tems 
(wet layup, prepreg, precured). Factors such as fiber volume, 
are saturated in-place and cured in-place and, in this 
type of fiber, type of resin, fiber orientation, dimensional 
sense, are analogous to cast-in-place concrete. Three common 
effects, and quality control during manufacturing all play a 
types of wet layup systems are listed as follows: 
role in establishing the characteristics of an FRP material. The 
1. Dry unidirectional fiber sheets where the fibers run 
material characteristics described in this chapter are generic and 
predominantly in one planar direction; 
do not apply to all commercially available products. Standard 
2. Dry multidirectional fiber sheets or fabrics where the 
test methods are being developed by several organizations 
fibers are oriented in at least two planar directions; and 
including ASTM, ACI, and ISIS to characterize certain FRP 
3. Dry fiber tows that are wound or otherwise mechanically 
products. In the interim, however, the engineer is encouraged to 
applied to the concrete surface. The dry fiber tows are im-pregnated 
consult with the FRP system manufacturer to obtain the relevant 
with resin on-site during the winding operation. 
characteristics for a specific product and the applicability of 
2.2.2 Prepreg systems—Prepreg FRP systems consist of 
those characteristics. 
uncured unidirectional or multidirectional fiber sheets or 
fabrics that are preimpregnated with a saturating resin in the 
3.1—Constituent materials 
manufacturer’s facility. Prepreg systems are bonded to the 
The constituent materials used in commercially available 
concrete surface with or without an additional resin application, 
FRP repair systems, including all resins, primers, putties, 
depending upon specific system requirements. Prepreg 
saturants, adhesives, and fibers, have been developed for the 
systems are saturated off-site and, like wet layup systems, 
strengthening of structural concrete members based on 
cured in place. Prepreg systems usually require additional 
materials and structural testing. 
heating for curing. Prepreg system manufacturers should be 
3.1.1 Resins—A wide range of polymeric resins, including 
consulted for storage and shelf-life recommendations and 
primers, putty fillers, saturants, and adhesives, are used with 
curing procedures. Three common types of prepreg FRP 
FRP systems. Commonly used resin types including epoxies, 
systems are listed as follows: 
vinyl esters, and polyesters have been formulated for use in
440.2R-10 ACI COMMITTEE REPORT 
Table 3.1—Typical densities of FRP materials, 
3.2—com 
Physical properties 
lb/ft3 (g/cm3) 
3.2.1 Density—FRP materials have densities ranging from 
75 to 130 lb/ft3 (1.2 to 2.1 g/cm3), which is four to six times 
Steel GFRP CFRP AFRP 
lower than that of steel (Table 3.1). The reduced density 
490 
75 to 130 
90 to 100 
75 to 90 
(7.9) 
(1.2 to 2.1) 
(1.5 to 1.6) 
(1.2 to 1.5) 
leads to lower transportation costs, reduces added dead load 
on the structure, and can ease handling of the materials on 
the project site. 
Table 3.2—Typical coefficients of thermal 
3.2.2 Coefficient of thermal expansion—The coefficients 
expansion for FRP materials* 
of thermal expansion of unidirectional FRP materials differ 
´ 10–6/°´ 10–6/°in the longitudinal and transverse directions, depending on 
Direction Coefficient of thermal expansion, F (C) 
the types of fiber, resin, and volume fraction of fiber. Table 3.2 
GFRP CFRP AFRP 
lists the longitudinal and transverse coefficients of thermal 
Longitudinal, a3.3 to 5.6 
–0.6 to 0 
–3.3 to –1.1 
L 
(6 to 10) 
(–1 to 0) 
(–6 to –2) 
expansion for typical unidirectional FRP materials. Note that 
10.4 to 12.6 
12 to 27 
33 to 44 
a negative coefficient of thermal expansion indicates that the 
Transverse, aT 
(19 to 23) 
(22 to 50) 
(60 to 80) 
material contracts with increased temperature and expands 
*afzir.with decreased temperature. For reference, concrete has a 
Typical values for fiber-volume fractions ranging from 0.5 to 0.7. 
coefficient of thermal expansion that varies from 4 ´ 10–6 to 
10–6/°10–6 10–6/°a wide range of environmental conditions. FRP system 
6 ´ F (7 ´ to 11 ´ C) and is usually assumed 
manufacturers use resins that have the following characteristics: 
to be isotropic (Mindess and Young 1981). Steel has an 
isotropic coefficient of thermal expansion of 6.5 ´ 10–6/°F 
• Compatibility with and adhesion to the concrete substrate; 
(11.7 ´ 10–6/°C). See Section 8.3.1 for design considerations 
• Compatibility with and adhesion to the FRP composite 
regarding thermal expansion. 
system; 
3.2.3 Effects of high temperatures—Beyond the Tg, the 
• Resistance to environmental effects, including but not 
elastic modulus of a polymer is significantly reduced due to 
limited to moisture, salt water, temperature extremes, and 
changes in its molecular structure. The value of Tg depends 
chemicals normally associated with exposed concrete; 
on the type of resin but is normally in the region of 140 to 
• Filling ability; 
180 °F (60 to 82 °C). In an FRP composite material, the fibers, 
• Workability; 
which exhibit better thermal properties than the resin, can 
• Pot life consistent with the application; 
continue to support some load in the longitudinal direction 
• Compatibility with and adhesion to the reinforcing 
until the temperature threshold of the fibers is reached. This 
fiber; and 
can occur at temperatures near 1800 °F (1000 °C) for glass 
• Development of appropriate mechanical properties for 
fibers and 350 °F (175 °C) for aramid fibers. Carbon fibers 
www.the FRP composite. 
are capable of resisting temperatures in excess of 500 °F 
(275 °C). Due to a reduction in force transfer between fibers 
3.1.1.1 Primer—The primer is used to penetrate the 
through bond to the resin, however, the tensile properties of 
surface of the concrete, providing an improved adhesive 
the overall composite are reduced. Test results have indicated 
bond for the saturating resin or adhesive. 
that temperatures of 480 °F (250 °C), much higher than the 
3.1.1.2 Putty fillers—The putty is used to fill small surface 
resin Tg, will reduce the tensile strength of GFRP and CFRP 
voids in the substrate, such as bug holes, and to provide a 
materials in excess of 20% (Kumahara et al. 1993). Other 
smooth surface to which the FRP system can bond. Filled 
properties affected by the shear transfer through the resin, 
surface voids also prevent bubbles from forming during 
such as bending strength, are reduced significantly at lower 
curing of the saturating resin. 
temperatures (Wang and Evans 1995). 
3.1.1.3 Saturating resin—The saturating resin is used to 
For bond-critical applications of FRP systems, the properties 
impregnate the reinforcing fibers, fix them in place, and 
of the polymer at the fiber-concrete interface are essential in 
provide a shear load path to effectively transfer load between 
maintaining the bond between FRP and concrete. At a tempera-ture 
fibers. The saturating resin also serves as the adhesive for 
close to its Tg, however, the mechanical properties of the 
wet layup systems, providing a shear load path between the 
polymer are significantly reduced, and the polymer begins to 
previously primed concrete substrate and the FRP system. 
loose its ability to transfer stresses from the concrete to the fibers. 
3.1.1.4 Adhesives—Adhesives are used to bond precured 
FRP laminate systems to the concrete substrate. The adhesive 
3.3—Mechanical properties and behavior 
provides a shear load path between the concrete substrate and 
3.3.1 Tensile behavior—When loaded in direct tension, 
the FRP reinforcing laminate. Adhesives are also used to bond 
FRP materials do not exhibit any plastic behavior (yielding) 
together multiple layers of precured FRP laminates. 
before rupture. The tensile behavior of FRP materials 
3.1.1.5 Protective coatings—The protective coating is 
consisting of one type of fiber material is characterized by a 
used to protect the bonded FRP reinforcement from potentially 
linearly elastic stress-strain relationship until failure, which 
damaging environmental effects. Coatings are typically 
is sudden and can be catastrophic. 
applied to the exterior surface of the cured FRP system after 
The tensile strength and stiffness of an FRP material is 
the adhesive or saturating resin has cured. 
dependent on several factors. Because the fibers in an FRP 
3.1.2 Fibers—Continuous glass, aramid, and carbon fibers 
material are the main load-carrying constituent, the type of 
are common reinforcements used with FRP systems. The fibers 
fiber, the orientation of the fibers, and the quantity of fibers 
give the FRP system its strength and stiffness. Typical ranges of 
primarily govern the tensile properties of the FRP material. 
the tensile properties of fibers are given in Appendix A. A more 
Due to the primary role of the fibers and methods of application, 
detailed description of fibers is given in ACI 440R. 
the properties of an FRP repair system are sometimes reported
DESIGN AND CONSTRUCTION OF EXTERNALLY BONDED FRP SYSTEMS 440.2R-11 
based on the net-fiber area. In other instances, the reported 
the fiber-com 
volume fraction, and the type of resin. Compressive 
properties are based on the gross-laminate area. 
strengths of 55, 78, and 20% of the tensile strength have been 
The gross-laminate area of an FRP system is calculated using 
reported for GFRP, CFRP, and AFRP, respectively (Wu 
the total cross-sectional area of the cured FRP system, including 
1990). In general, compressive strengths are higher for 
all fibers and resin. The gross-laminate area is typically used 
materials with higher tensile strengths, except in the case 
for reporting precured laminate properties where the cured 
of AFRP where the fibers exhibit nonlinear behavior in 
thickness is constant and the relative proportion of fiber and 
compression at a relatively low level of stress. 
resin is controlled. 
The compressive modulus of elasticity is usually smaller 
The net-fiber area of an FRP system is calculated using the 
than the tensile modulus of elasticity of FRP materials. 
known area of fiber, neglecting the total width and thickness 
Test reports on samples containing a 55 to 60% volume fraction 
of the cured system; thus, resin is excluded. The net-fiber 
of continuous E-glass fibers in a matrix of vinyl ester or 
area is typically used for reporting properties of wet layup sys-tems 
isophthalic polyester resin have reported a compressive 
that use manufactured fiber sheets and field-installed 
modulus of elasticity of 5000 to 7000 ksi (34,000 to 
resins. The wet layup installation process leads to a con-trolled 
48,000 MPa) (Wu 1990). According to reports, the compressive 
fiber content and a variable resin content. 
modulus of elasticity is approximately 80% for GFRP, 85% 
System properties reported using the gross-laminate area have 
for CFRP, and 100% for AFRP of the tensile modulus of 
higher relative thickness dimensions and lower relative strength 
elasticity for the same product (Ehsani 1993). 
and modulus values, whereas system properties reported using 
the net-fiber area have lower relative afzir.thickness dimensions and 
3.4—Time-dependent behavior 
higher relative strength and modulus values. Regardless of the 
3.4.1 Creep-rupture—FRP materials subjected to a constant 
basis for the reported values, the load-carrying strength (ffuAf) 
load over time can suddenly fail after a time period referred 
and stiffness (Af Ef) remain constant. (The calculation of FRP 
to as the endurance time. This type of failure is known as 
system properties using both gross-laminate and net-fiber 
creep-rupture. As the ratio of the sustained tensile stress to 
property methods is illustrated in Part 5.) Properties reported 
the short-term strength of the FRP laminate increases, endurance 
based on the net-fiber area are not the properties of the 
time decreases. The endurance time also decreases under 
bare fibers. The properties of an FRP system should be 
adverse environmental conditions, such as high temperature, 
characterized as a composite, recognizing not just the material 
ultraviolet-radiation exposure, high alkalinity, wet and dry 
properties of the individual fibers but also the efficiency of 
cycles, or freezing-and-thawing cycles. 
the fiber-resin system, the fabric architecture, and the method 
In general, carbon fibers are the least susceptible to creep-rupture; 
used to create the composite. The mechanical properties of all 
aramid fibers are moderately susceptible, and glass 
FRP systems, regardless of form, should be based on the testing 
fibers are most susceptible. Creep-rupture tests have been 
of laminate samples with a known fiber content. 
conducted on 0.25 in. (6 mm) diameter FRP bars reinforced 
www.The tensile properties of some commercially available 
with glass, aramid, and carbon fibers. The FRP bars were 
FRP strengthening systems are given in Appendix A. The 
tested at different load levels at room temperature. Results 
tensile properties of a particular FRP system, however, 
indicated that a linear relationship exists between creep-rupture 
should be obtained from the FRP system manufacturer. 
strength and the logarithm of time for all load levels. 
Manufacturers should report an ultimate tensile strength defined 
The ratios of stress level at creep-rupture after 500,000 h 
by this guide as the mean tensile strength of a sample of test 
(about 50 years) to the initial ultimate strength of the GFRP, 
specimens minus three times the standard deviation (ffu 
* = 
AFRP, and CFRP bars were extrapolated to be 0.3, 0.47, and 
ffu 
– 3s) and, similarly, report an ultimate rupture strain 
0.91, respectively (Yamaguchi et al. 1997). Similar values 
(ef= eshave been determined elsewhere (Malvar 1998). 
fu 
– 3). These statistically based ultimate tensile 
properties provide a 99.87% probability that the indicated 
Recommendations on sustained stress limits imposed to 
values are exceeded (Mutsuyoshi et al. 1990). Young’s modulus 
avoid creep-rupture are given in the design section of this 
should be calculated as the chord modulus between 0.003 
guide. As long as the sustained stress in the FRP is below the 
and 0.006 strain, in accordance with ASTM D 3039. A 
creep rupture stress limits, the strength of the FRP is available 
minimum number of 20 replicate test specimens should be 
for nonsustained loads. 
used to determine the ultimate tensile properties. The 
3.4.2 Fatigue—A substantial amount of data for fatigue 
manufacturer should provide a description of the method 
behavior and life prediction of stand-alone FRP materials have 
used to obtain the reported tensile properties, including the 
been generated in the last 30 years (National Research Council 
number of tests, mean values, and standard deviations. 
1991). During most of this period, aerospace materials were the 
3.3.2 Compressive behavior—Externally bonded FRP 
primary subjects of investigation. Despite the differences in 
systems should not be used as compression reinforcement 
quality and consistency between aerospace and commercial-grade 
due to insufficient testing validating its use in this type of 
FRP materials, some general observations on the fatigue 
application. While it is not recommended to rely on externally 
behavior of FRP materials can be made. Unless specifically 
bonded FRP systems to resist compressive stresses, the 
stated otherwise, the following cases being reviewed are based 
following section is presented to fully characterize the 
on an unidirectional material with approximately 60% fiber-volume 
behavior of FRP materials. 
fraction and subjected to tension-tension sinusoidal 
Coupon tests on FRP laminates used for repair on concrete 
cyclic loading at: 
have shown that the compressive strength is lower than the 
• A frequency low enough to not cause self-heating; 
tensile strength (Wu 1990). The mode of failure for FRP 
• Ambient laboratory environments; 
laminates subjected to longitudinal compression can include 
• A stress ratio (ratio of minimum applied stress to 
transverse tensile failure, fiber microbuckling, or shear 
maximum applied stress) of 0.1; and 
failure. The mode of failure depends on the type of fiber, 
• A direction parallel to the principal fiber alignment. 
u *
440.2R-12 ACI COMMITTEE REPORT 
Test conditions that raise the temperature and moisture 
exposure. com 
These properties should be adjusted in accordance 
content of FRP materials generally degrade the ambient 
with Section 8.4 to account for the anticipated service environ-ment 
environment fatigue behavior. 
to which the FRP system may be exposed during its 
Of all types of FRP composites for infrastructure applications, 
service life. 
CFRP is the least prone to fatigue failure. An endurance limit 
of 60 to 70% of the initial static ultimate strength of CFRP is 
3.6—FRP system qualification 
typical. On a plot of stress versus the logarithm of the number of 
FRP systems should be qualified for use on a project on the 
cycles at failure (S-N curve), the downward slope of CFRP 
basis of independent laboratory test data of the FRP-constituent 
is usually about 5% of the initial static ultimate strength per 
materials and the laminates made with them, structural test 
decade of logarithmic life. At one million cycles, the fatigue 
data for the type of application being considered, and durability 
strength is generally between 60 and 70% of the initial static 
data representative of the anticipated environment. Test data 
ultimate strength and is relatively unaffected by the moisture 
provided by the FRP system manufacturer demonstrating the 
and temperature exposures of concrete structures unless the 
proposed FRP system meets all mechanical and physical 
resin or fiber/resin interface is afzir.substantially degraded by the 
design requirements including tensile strength, durability, 
environment. 
resistance to creep, bond to substrate, and Tg should be 
In ambient-environment laboratory tests (Mandell and 
considered but not used as the sole basis for qualification. 
Meier 1983), individual glass fibers demonstrated delayed 
FRP composite systems that have not been fully tested 
rupture caused by stress corrosion, which had been induced 
should not be considered for use. Mechanical properties 
by the growth of surface flaws in the presence of even minute 
of FRP systems should be determined from tests on laminates 
quantities of moisture. When many glass fibers are embedded 
manufactured in a process representative of their field installa-tion. 
into a matrix to form an FRP composite, a cyclic tensile 
Mechanical properties should be tested in general 
fatigue effect of approximately 10% loss in the initial static 
conformance with the procedures listed in Appendix B. 
strength per decade of logarithmic lifetime is observed 
Modifications of standard testing procedures may be permitted 
(Mandell 1982). This fatigue effect is thought to be due to fiber-fiber 
to emulate field assemblies. 
interactions and not dependent on the stress corrosion 
The specified material-qualification programs should 
mechanism described for individual fibers. Usually, no 
require sufficient laboratory testing to measure the repeatability 
clear fatigue limit can be defined. Environmental factors 
and reliability of critical properties. Testing of multiple 
can play an important role in the fatigue behavior of glass 
batches of FRP materials is recommended. Independent 
fibers due to their susceptibility to moisture, alkaline, 
structural testing can be used to evaluate a system’s performance 
and acidic solutions. 
for the specific application. 
Aramid fibers, for which substantial durability data are 
available, appear to behave reasonably well in fatigue. 
PART 3—RECOMMENDED 
www.Neglecting in this context the rather poor durability of all 
CONSTRUCTION REQUIREMENTS 
aramid fibers in compression, the tension-tension fatigue 
CHAPTER 4—SHIPPING, STORAGE, AND 
behavior of an impregnated aramid fiber strand is excellent. 
HANDLING 
Strength degradation per decade of logarithmic lifetime is 
4.1—Shipping 
approximately 5 to 6% (Roylance and Roylance 1981). 
FRP system constituent materials must be packaged and 
While no distinct endurance limit is known for AFRP, two-million- 
shipped in a manner that conforms to all applicable federal 
cycle endurance limits of commercial AFRP tendons 
and state packaging and shipping codes and regulations. 
for concrete applications have been reported in the range of 
Packaging, labeling, and shipping for thermosetting resin 
54 to 73% of the ultimate tensile strength (Odagiri et al. 
materials are controlled by CFR 49. Many materials are 
1997). Based on these findings, Odagiri suggested that the 
classified as corrosive, flammable, or poisonous in subchapter C 
maximum stress be set to 0.54 to 0.73 times the tensile 
(CFR 49) under “Hazardous Materials Regulations.” 
strength. Because the slope of the applied stress versus 
logarithmic endurance time of AFRP is similar to the slope 
4.2—Storage 
of the stress versus logarithmic cyclic lifetime data, the 
4.2.1 Storage conditions—To preserve the properties and 
individual fibers appear to fail by a strain-limited, creep-rupture 
maintain safety in the storage of FRP system constituent 
process. This lifetime-limiting mechanism in 
materials, the materials should be stored in accordance with 
commercial AFRP bars is accelerated by exposure to moisture 
the manufacturer’s recommendations. Certain constituent 
and elevated temperature (Roylance and Roylance 1981; 
materials, such as reactive curing agents, hardeners, initiators, 
Rostasy 1997). 
catalysts, and cleaning solvents, have safety-related require-ments 
and should be stored in a manner as recommended by 
3.5—Durability 
the manufacturer and OSHA. Catalysts and initiators (usually 
Many FRP systems exhibit reduced mechanical properties 
peroxides) should be stored separately. 
after exposure to certain environmental factors, including 
4.2.2 Shelf life—The properties of the uncured resin 
temperature, humidity, and chemical exposure. The exposure 
components can change with time, temperature, or humidity. 
environment, duration of the exposure, resin type and 
Such conditions can affect the reactivity of the mixed system 
formulation, fiber type, and resin-curing method are 
and the uncured and cured properties. The manufacturer sets 
some of the factors that influence the extent of the reduction in 
a recommended shelf life within which the properties of the 
mechanical properties. These factors are discussed in more 
resin-based materials should continue to meet or exceed 
detail in Section 8.3. The tensile properties reported by the 
stated performance criteria. Any component material that 
manufacturer are based on testing conducted in a laboratory 
has exceeded its shelf life, has deteriorated, or has been 
environment and do not reflect the effects of environmental 
contaminated should not be used. FRP materials deemed
DESIGN AND CONSTRUCTION OF EXTERNALLY BONDED FRP SYSTEMS 440.2R-13 
unusable should be disposed of in a manner specified by the 
Consult com 
the manufacturer’s literature for proper mixing 
manufacturer and acceptable to state and federal environmental 
procedures and MSDSs for specific handling hazards. Ambient 
control regulations. 
cure resin formulations produce heat when curing, which in 
turn accelerates the reaction. Uncontrolled reactions, including 
4.3—Handling 
fuming, fire, or violent boiling, may occur in containers 
4.3.1 Material safety data sheets—Material safety data 
holding a mixed mass of resin; therefore, containers should 
sheets (MSDS) for all FRP constituent materials and 
be monitored. 
components must be obtained from the manufacturers and 
4.3.6 Clean-up and disposal—Clean-up can involve use 
must be accessible at the job site. 
of flammable solvents, and appropriate precautions 
4.3.2 Information sources—Detailed information on the 
should be observed. Clean-up solvents are available that do 
handling and potential hazards of FRP constituent materials 
not present the same flammability concerns. All waste materials 
can be found in information sources, such as ACI and ICRI 
should be contained and disposed of as prescribed by the prevail-ing 
reports, company literature and guides, OSHA guidelines, 
environmental authority. 
and other government informational documents. ACI 503R 
is specifically noted as a general guideline for the safe handling 
CHAPTER 5—INSTALLATION 
of epoxy compounds. 
Procedures for installing FRP systems have been developed 
4.3.3 General handling hazards—Thermosetting resins 
by the system manufacturers and often differ between systems. 
describe a generic family of products that includes unsaturated 
In addition, installation procedures can vary within a system, 
polyesters, vinyl esters, epoxy, and polyurethane resins. The 
depending on the type and condition of the structure. This 
materials used with them are generally described as hardeners, 
chapter presents general guidelines for the installation of FRP 
curing agents, peroxide initiators, isocyanates, fillers, and 
systems. Contractors trained in accordance with the installation 
flexibilizers. There are precautions that should be observed 
procedures developed by the system manufacturer should 
when handling thermosetting resins and their component 
install FRP systems. Deviations from the procedures developed 
materials. Some general hazards that may be encountered 
by the FRP system manufacturer should not be allowed without 
when handling thermosetting resins are listed as follows: 
consulting with the manufacturer. 
• Skin irritation, such as burns, afzir.rashes, and itching; 
• Skin sensitization, which is an allergic reaction similar 
5.1—Contractor competency 
to that caused by poison ivy, building insulation, or 
The FRP system installation contractor should demonstrate 
other allergens; 
competency for surface preparation and application of the FRP 
• Breathing organic vapors from cleaning solvents, 
system to be installed. Contractor competency can be demon-strated 
monomers, and diluents; 
by providing evidence of training and documentation of 
• With a sufficient concentration in air, explosion or fire 
related work previously completed by the contractor or by actual 
www.of flammable materials when exposed to heat, flames, 
surface preparation and installation of the FRP system on 
pilot lights, sparks, static electricity, cigarettes, or other 
portions of the structure. The FRP system manufacturer or their 
sources of ignition; 
authorized agent should train the contractor’s application 
• Exothermic reactions of mixtures of materials causing 
personnel in the installation procedures of their system and 
fires or personal injury; and 
ensure they are competent to install the system. 
• Nuisance dust caused by grinding or handling of the 
cured FRP materials (consult manufacturer’s literature 
5.2—Temperature, humidity, and moisture 
for specific hazards). 
considerations 
The complexity of thermosetting resins and associated 
Temperature, relative humidity, and surface moisture at 
materials makes it essential that labels and MSDS are read and 
the time of installation can affect the performance of the FRP 
understood by those working with these products. CFR 16, Part 
system. Conditions to be observed before and during installation 
1500, regulates the labeling of hazardous substances and 
include surface temperature of the concrete, air temperature, 
includes thermosetting-resin materials. ANSI Z-129.1 provides 
relative humidity, and corresponding dew point. 
further guidance regarding classification and precautions. 
Primers, saturating resins, and adhesives generally should 
4.3.4 Personnel safe handling and clothing—Disposable 
not be applied to cold or frozen surfaces. When the surface 
suits and gloves are suitable for handling fiber and resin 
temperature of the concrete surface falls below a minimum 
materials. Disposable rubber or plastic gloves are recommended 
level as specified by the FRP system manufacturer, improper 
and should be discarded after each use. Gloves should be 
saturation of the fibers and improper curing of the resin 
resistant to resins and solvents. 
constituent materials can occur, compromising the integrity 
Safety glasses or goggles should be used when handling 
of the FRP system. An auxiliary heat source can be used to 
resin components and solvents. Respiratory protection, such 
raise the ambient and surface temperature during installation. 
as dust masks or respirators, should be used when fiber fly, 
The heat source should be clean and not contaminate the surface 
dust, or organic vapors are present, or during mixing and 
or the uncured FRP system. 
placing of resins if required by the FRP system manufacturer. 
Resins and adhesives generally should not be applied to 
4.3.5 Workplace safe handling—The workplace should be 
damp or wet surfaces unless they have been formulated for 
well ventilated. Surfaces should be covered as needed to 
such applications. FRP systems should not be applied to concrete 
protect against contamination and resin spills. Each FRP 
surfaces that are subject to moisture vapor transmission. The 
system constituent material has different handling and 
transmission of moisture vapor from a concrete surface 
storage requirements to prevent damage. Consult with the 
through the uncured resin materials typically appears as 
material manufacturer for guidance. Some resin systems are 
surface bubbles and can compromise the bond between the 
potentially dangerous during the mixing of the components. 
FRP system and the substrate.
440.2R-14 ACI COMMITTEE REPORT 
5.3—Equipment 
adhesive com 
bond between the FRP system and the concrete 
Each FRP system has unique equipment designed specifically 
substrate, although one is often provided to facilitate installation. 
for the application of the materials for that system. This 
5.4.2.1 Bond-critical applications—Surface preparation 
equipment can include resin impregnators, sprayers, lifting/ 
for bond-critical applications should be in accordance with 
positioning devices, and winding machines. All equipment 
recommendations of ACI 546R and ICRI 03730. The 
should be clean and in good operating condition. The 
concrete or repaired surfaces to which the FRP system is to 
contractor should have personnel trained in the operation of 
be applied should be freshly exposed and free of loose or 
all equipment. Personal protective equipment, such as 
unsound materials. Where fibers wrap around the corners of 
gloves, masks, eye guards, and coveralls, should be chosen 
rectangular cross sections, the corners should be rounded to 
and worn for each employee’s function. All supplies and 
a minimum 1/2 in. (13 mm) radius to prevent stress concentra-tions 
equipment should be available in sufficient quantities to allow 
in the FRP system and voids between the FRP system 
continuity in the installation project and quality assurance. 
and the concrete. Roughened corners should be smoothed 
with putty. Obstructions, reentrant corners, concave surfaces, 
5.4—Substrate repair and afzir.surface preparation 
and embedded objects can affect the performance of the FRP 
The behavior of concrete members strengthened or retrofitted 
system and should be addressed. Obstructions and embedded 
with FRP systems is highly dependent on a sound concrete 
objects may need to be removed before installing the FRP 
substrate and proper preparation and profiling of the concrete 
system. Reentrant corners and concave surfaces may require 
surface. An improperly prepared surface can result in debonding 
special detailing to ensure that the bond of the FRP system to the 
or delamination of the FRP system before achieving the design 
substrate is maintained. Surface preparation can be accom-plished 
load transfer. The general guidelines presented in this chapter 
using abrasive or water-blasting techniques. All laitance, 
should be applicable to all externally bonded FRP systems. 
dust, dirt, oil, curing compound, existing coatings, and any other 
Specific guidelines for a particular FRP system should be 
matter that could interfere with the bond of the FRP system to 
obtained from the FRP system manufacturer. Substrate 
the concrete should be removed. Bug holes and other small 
preparation can generate noise, dust, and disruption to building 
surface voids should be completely exposed during surface 
occupants. 
profiling. After the profiling operations are complete, the 
5.4.1 Substrate repair—All problems associated with the 
surface should be cleaned and protected before FRP installation 
condition of the original concrete and the concrete substrate 
so that no materials that can interfere with bond are redeposited 
that can compromise the integrity of the FRP system should 
on the surface. 
be addressed before surface preparation begins. ACI 546R and 
The concrete surface should be prepared to a minimum 
ICRI 03730 detail methods for the repair and surface preparation 
concrete surface profile (CSP) 3 as defined by the ICRI-surface- 
of concrete. All concrete repairs should meet the requirements 
profile chips. The FRP system manufacturer should 
of the design drawings and project specifications. The FRP 
be consulted to determine if more aggressive surface profiling 
www.system manufacturer should be consulted on the compatibility 
is necessary. Localized out-of-plane variations, including 
of the materials used for repairing the substrate with the FRP 
form lines, should not exceed 1/32 in. (1 mm) or the tolerances 
system. 
recommended by the FRP system manufacturer. Localized 
5.4.1.1 Corrosion-related deterioration—Externally 
out-of-plane variations can be removed by grinding before 
bonded FRP systems should not be applied to concrete 
abrasive or water blasting or can be smoothed over using epoxy 
substrates suspected of containing corroded reinforcing 
putty if the variations are very small. Bug holes and voids 
steel. The expansive forces associated with the corrosion 
should be filled with epoxy putty. 
process are difficult to determine and could compromise the 
All surfaces to receive the strengthening system should be 
structural integrity of the externally applied FRP system. 
as dry as recommended by the FRP system manufacturer. 
The cause(s) of the corrosion should be addressed and the 
Water in the pores can inhibit resin penetration and reduce 
corrosion-related deterioration should be repaired before the 
mechanical interlocking. Moisture content should be 
application of any externally bonded FRP system. 
evaluated in accordance with the requirements of ACI 503.4. 
5.4.1.2 Injection of cracks—Some FRP manufacturers 
5.4.2.2 Contact-critical applications—In applications 
have reported that the movement of cracks 0.010 in. (0.3 mm) 
involving confinement of structural concrete members, 
and wider can affect the performance of the externally bonded 
surface preparation should promote continuous intimate 
FRP system through delamination or fiber crushing. Con-sequently, 
contact between the concrete surface and the FRP system. 
cracks wider than 0.010 in. (0.3 mm) should be 
Surfaces to be wrapped should, at a minimum, be flat or 
pressure injected with epoxy in accordance with ACI 224.1R. 
convex to promote proper loading of the FRP system. Large 
Smaller cracks exposed to aggressive environments may require 
voids in the surface should be patched with a repair material 
resin injection or sealing to prevent corrosion of existing 
compatible with the existing concrete. 
steel reinforcement. Crack-width criteria for various exposure 
Materials with low compressive strength and elastic modulus, 
conditions are given in ACI 224R. 
like plaster, can reduce the effectiveness of the FRP system 
5.4.2 Surface preparation—Surface preparation requirements 
and should be removed. 
should be based on the intended application of the FRP system. 
Applications can be categorized as bond-critical or contact-critical. 
5.5—Mixing of resins 
Bond-critical applications, such as flexural or shear 
Mixing of resins should be done in accordance with the FRP 
strengthening of beams, slabs, columns, or walls, require an 
system manufacturer’s recommended procedure. All resin 
adhesive bond between the FRP system and the concrete. 
components should be at a proper temperature and mixed in the 
Contact-critical applications, such as confinement of columns, 
correct ratio until there is a uniform and complete mixing of 
only require intimate contact between the FRP system and 
components. Resin components are often contrasting colors, so 
the concrete. Contact-critical applications do not require an 
full mixing is achieved when color streaks are eliminated.
DESIGN AND CONSTRUCTION OF EXTERNALLY BONDED FRP SYSTEMS 440.2R-15 
Resins should be mixed for the prescribed mixing time and 
Dry fibers are impregnated at the job site during the winding 
visually inspected for uniformity of color. The material 
process. 
manufacturer should supply recommended batch sizes, mixture 
Wrapping machines are primarily used for the automated 
ratios, mixing methods, and mixing times. 
wrapping of concrete columns. The tows can be wound either 
Mixing equipment can include small electrically powered 
horizontally or at a specified angle. The wrapping machine 
mixing blades or specialty units, or resins can be mixed by 
is placed around the column and automatically wraps the tow 
hand stirring, if needed. Resin mixing should be in quantities 
material around the perimeter of the column while moving 
sufficiently small to ensure that all mixed resin can be used 
up and down the column. 
within the resin’s pot life. Mixed resin that exceeds its pot 
After wrapping, prepreg systems should be cured at an 
life should not be used because the viscosity will continue to 
elevated com 
temperature. Usually a heat source is placed around 
increase and will adversely affect the resin’s ability to 
the column for a predetermined temperature and time schedule 
penetrate the surface or saturate the fiber sheet. 
in accordance with the manufacturer’s recommendations. 
Temperatures are controlled to ensure consistent quality. The 
5.6—Application of constituent materials 
resulting FRP jackets do not have any seams or welds because 
Fumes can accompany the application of some FRP resins. 
the tows are continuous. In all of the previous application steps, 
FRP systems should be selected with consideration for their 
the FRP system manufacturer’s recommendations should be 
impact on the environment, including emission of volatile 
followed. 
organic compounds and toxicology. 
5.6.4 Precured systems—Precured systems include shells, 
5.6.1 Primer and putty—Where required, primer should 
strips, and open grid forms that are typically installed with an 
be applied to all areas on the concrete afzir.surface where the FRP 
adhesive. Adhesives should be uniformly applied to the 
system is to be placed. The primer should be placed uniformly 
prepared surfaces where precured systems are to be placed, 
on the prepared surface at the manufacturer’s specified rate 
except in certain instances of concrete confinement where 
of coverage. The applied primer should be protected from 
adhesion of the FRP system to the concrete substrate may not 
dust, moisture, and other contaminants prior to applying the 
be required. 
FRP system. 
Precured laminate surfaces to be bonded should be clean 
and prepared in accordance with the manufacturer’s recommen-dation. 
Putty should be used in an appropriate thickness and 
The precured sheets or curved shells should be placed 
sequence with the primer as recommended by the FRP 
on or into the wet adhesive in a manner recommended by the 
manufacturer. The system-compatible putty, which is typically 
FRP manufacturer. Entrapped air between layers should 
a thickened epoxy paste, should be used only to fill voids and 
be released or rolled out before the adhesive sets. Adhesive 
smooth surface discontinuities before the application of other 
should be applied at a rate recommended by the FRP 
materials. Rough edges or trowel lines of cured putty should 
manufacturer to ensure full bonding of successive layers. 
be ground smooth before continuing the installation. 
www.5.6.5 Protective coatings—Coatings should be compatible 
Prior to applying the saturating resin or adhesive, the primer 
with the FRP strengthening system and applied in accordance 
and putty should be allowed to cure as specified by the FRP 
with the manufacturer’s recommendations. Typically, the 
system manufacturer. If the putty and primer are fully cured, 
use of solvents to clean the FRP surface prior to installing 
additional surface preparation may be required prior to the 
coatings is not recommended due to the deleterious effects 
application of the saturating resin or adhesive. Surface 
solvents can have on the polymer resins. The FRP system 
preparation requirements should be obtained from the FRP 
manufacturer should approve any use of solvent-wipe 
system manufacturer. 
preparation of FRP surfaces before the application of 
5.6.2 Wet layup systems—Wet layup FRP systems are 
protective coatings. 
typically installed by hand using dry fiber sheets and a 
The coatings should be periodically inspected and 
saturating resin, and the manufacturer’s recommendations 
maintenance should be provided to ensure the effectiveness 
should be followed. The saturating resin should be applied 
of the coatings. 
uniformly to all prepared surfaces where the system is to be 
placed. The fibers can also be impregnated in a separate process 
5.7—Alignment of FRP materials 
using a resin-impregnating machine before placement on the 
The FRP-ply orientation and ply-stacking sequence should 
concrete surface. 
be specified. Small variations in angle, as little as 5 degrees, 
The reinforcing fibers should be gently pressed into the 
from the intended direction of fiber alignment can cause a 
uncured saturating resin in a manner recommended by the 
substantial reduction in strengthening. Deviations in ply 
FRP system manufacturer. Entrapped air between layers 
orientation should only be made if approved by the engineer. 
should be released or rolled out before the resin sets. Sufficient 
Sheet and fabric materials should be handled in a manner 
saturating resin should be applied to achieve full saturation of 
to maintain the fiber straightness and orientation. Fabric 
the fibers. 
kinks, folds, or other forms of severe waviness should be 
Successive layers of saturating resin and fiber materials 
reported to the engineer. 
should be placed before the complete cure of the previous 
layer of resin. If previous layers are cured, interlayer surface 
5.8—Multiple plies and lap splices 
preparation, such as light sanding or solvent application as 
Multiple plies can be used, provided all plies are fully 
recommended by the system manufacturer, may be required. 
impregnated with the resin system, the resin shear strength is 
5.6.3 Machine-applied systems—Machine-applied systems 
sufficient to transfer the shearing load between plies, and the 
can use resin-preimpregnated tow or dry-fiber tows. Prepreg 
bond strength between the concrete and FRP system is 
tows are impregnated with saturating resin off-site and 
sufficient. For long spans, multiple lengths of fiber material 
delivered to the work site as spools of prepreg tow material. 
or precured stock can be used to continuously transfer the
Reinforced concrete
Reinforced concrete
Reinforced concrete
Reinforced concrete
Reinforced concrete
Reinforced concrete
Reinforced concrete
Reinforced concrete
Reinforced concrete
Reinforced concrete
Reinforced concrete
Reinforced concrete
Reinforced concrete
Reinforced concrete
Reinforced concrete
Reinforced concrete
Reinforced concrete
Reinforced concrete
Reinforced concrete
Reinforced concrete
Reinforced concrete
Reinforced concrete
Reinforced concrete
Reinforced concrete
Reinforced concrete
Reinforced concrete
Reinforced concrete
Reinforced concrete
Reinforced concrete
Reinforced concrete

More Related Content

Viewers also liked

Structural concrete, theory and design,4th ed
Structural concrete, theory and design,4th edStructural concrete, theory and design,4th ed
Structural concrete, theory and design,4th edSarmed Shukur
 
Extending service life of existing bridges
Extending service life of existing bridgesExtending service life of existing bridges
Extending service life of existing bridgesEva Lantsoght
 
Structural collapse awareness hmm
Structural collapse awareness hmmStructural collapse awareness hmm
Structural collapse awareness hmmDr. H.M.A. Mahzuz
 
Ch 10 Fire-Resistive Construction
Ch 10 Fire-Resistive ConstructionCh 10 Fire-Resistive Construction
Ch 10 Fire-Resistive Constructionsnoshoesam
 
Prolonging the service life of existing reinforced concrete slab bridges
Prolonging the service life of existing reinforced concrete slab bridgesProlonging the service life of existing reinforced concrete slab bridges
Prolonging the service life of existing reinforced concrete slab bridgesEva Lantsoght
 
Concrete Repair: Bridges and Tunnels--Epoxies
Concrete Repair: Bridges and Tunnels--Epoxies Concrete Repair: Bridges and Tunnels--Epoxies
Concrete Repair: Bridges and Tunnels--Epoxies jbors
 
polymers for concrete repair
polymers for concrete repairpolymers for concrete repair
polymers for concrete repairKris Kiran
 
Proof loading of existing bridges
Proof loading of existing bridges Proof loading of existing bridges
Proof loading of existing bridges Eva Lantsoght
 
Atelectasis and collapse in CXR
Atelectasis and collapse in CXRAtelectasis and collapse in CXR
Atelectasis and collapse in CXRMarco Wu
 
Chapter 2 seviceability and durability
Chapter 2 seviceability and durabilityChapter 2 seviceability and durability
Chapter 2 seviceability and durabilityAnkit Patel
 
CE 72.52 - Lecture 8b - Retrofitting of RC Members
CE 72.52 - Lecture 8b - Retrofitting of RC MembersCE 72.52 - Lecture 8b - Retrofitting of RC Members
CE 72.52 - Lecture 8b - Retrofitting of RC MembersFawad Najam
 
Earthquake collapse pattern
Earthquake collapse patternEarthquake collapse pattern
Earthquake collapse patternPakjum Nyori
 
Flexural behaviour of fibre reinforced ferrocement concrete
Flexural behaviour of fibre reinforced ferrocement concreteFlexural behaviour of fibre reinforced ferrocement concrete
Flexural behaviour of fibre reinforced ferrocement concreteSanthosh Jayaraman
 
retrofitting of existing rcc members Different strengthening techniques
retrofitting of existing rcc members Different strengthening techniquesretrofitting of existing rcc members Different strengthening techniques
retrofitting of existing rcc members Different strengthening techniquessuraj prasanna kumar
 

Viewers also liked (19)

Structural concrete, theory and design,4th ed
Structural concrete, theory and design,4th edStructural concrete, theory and design,4th ed
Structural concrete, theory and design,4th ed
 
Root cause analysis
Root cause analysisRoot cause analysis
Root cause analysis
 
Dissertation
DissertationDissertation
Dissertation
 
Extending service life of existing bridges
Extending service life of existing bridgesExtending service life of existing bridges
Extending service life of existing bridges
 
Strengthening of RC Arches
Strengthening of RC ArchesStrengthening of RC Arches
Strengthening of RC Arches
 
Structural collapse awareness hmm
Structural collapse awareness hmmStructural collapse awareness hmm
Structural collapse awareness hmm
 
Ch 10 Fire-Resistive Construction
Ch 10 Fire-Resistive ConstructionCh 10 Fire-Resistive Construction
Ch 10 Fire-Resistive Construction
 
Prolonging the service life of existing reinforced concrete slab bridges
Prolonging the service life of existing reinforced concrete slab bridgesProlonging the service life of existing reinforced concrete slab bridges
Prolonging the service life of existing reinforced concrete slab bridges
 
Conference ppt
Conference pptConference ppt
Conference ppt
 
Concrete Repair: Bridges and Tunnels--Epoxies
Concrete Repair: Bridges and Tunnels--Epoxies Concrete Repair: Bridges and Tunnels--Epoxies
Concrete Repair: Bridges and Tunnels--Epoxies
 
polymers for concrete repair
polymers for concrete repairpolymers for concrete repair
polymers for concrete repair
 
Proof loading of existing bridges
Proof loading of existing bridges Proof loading of existing bridges
Proof loading of existing bridges
 
Ferrocement roof
Ferrocement roofFerrocement roof
Ferrocement roof
 
Atelectasis and collapse in CXR
Atelectasis and collapse in CXRAtelectasis and collapse in CXR
Atelectasis and collapse in CXR
 
Chapter 2 seviceability and durability
Chapter 2 seviceability and durabilityChapter 2 seviceability and durability
Chapter 2 seviceability and durability
 
CE 72.52 - Lecture 8b - Retrofitting of RC Members
CE 72.52 - Lecture 8b - Retrofitting of RC MembersCE 72.52 - Lecture 8b - Retrofitting of RC Members
CE 72.52 - Lecture 8b - Retrofitting of RC Members
 
Earthquake collapse pattern
Earthquake collapse patternEarthquake collapse pattern
Earthquake collapse pattern
 
Flexural behaviour of fibre reinforced ferrocement concrete
Flexural behaviour of fibre reinforced ferrocement concreteFlexural behaviour of fibre reinforced ferrocement concrete
Flexural behaviour of fibre reinforced ferrocement concrete
 
retrofitting of existing rcc members Different strengthening techniques
retrofitting of existing rcc members Different strengthening techniquesretrofitting of existing rcc members Different strengthening techniques
retrofitting of existing rcc members Different strengthening techniques
 

Similar to Reinforced concrete

Design considerations for_steel_fiber_re
Design considerations for_steel_fiber_reDesign considerations for_steel_fiber_re
Design considerations for_steel_fiber_reUsman Muhammad
 
IRJET- Behavior of RC T-Beam Strengthen using Basalt Fiber Reinforced Pol...
IRJET-  	  Behavior of RC T-Beam Strengthen using Basalt Fiber Reinforced Pol...IRJET-  	  Behavior of RC T-Beam Strengthen using Basalt Fiber Reinforced Pol...
IRJET- Behavior of RC T-Beam Strengthen using Basalt Fiber Reinforced Pol...IRJET Journal
 
ACI 347R-14_Guía de encofrados para hormigón.pdf
ACI 347R-14_Guía de encofrados para hormigón.pdfACI 347R-14_Guía de encofrados para hormigón.pdf
ACI 347R-14_Guía de encofrados para hormigón.pdfMarianoAcimut
 
COMPARATIVE AND EXPERIMENTAL INVESTIGATION OF E -GLASS AND S-GLASS ARECA BANA...
COMPARATIVE AND EXPERIMENTAL INVESTIGATION OF E -GLASS AND S-GLASS ARECA BANA...COMPARATIVE AND EXPERIMENTAL INVESTIGATION OF E -GLASS AND S-GLASS ARECA BANA...
COMPARATIVE AND EXPERIMENTAL INVESTIGATION OF E -GLASS AND S-GLASS ARECA BANA...IRJET Journal
 
IRJET- EBR and GM Methods for External Flexural Strengthening of RC Beams
IRJET-  	  EBR and GM Methods for External Flexural Strengthening of RC BeamsIRJET-  	  EBR and GM Methods for External Flexural Strengthening of RC Beams
IRJET- EBR and GM Methods for External Flexural Strengthening of RC BeamsIRJET Journal
 
IRJET- Experimental Study on Retrofitted RC- Beams
IRJET- Experimental Study on Retrofitted RC- BeamsIRJET- Experimental Study on Retrofitted RC- Beams
IRJET- Experimental Study on Retrofitted RC- BeamsIRJET Journal
 
Strengthening reinforced concrete beams using fiber
Strengthening reinforced concrete beams using fiberStrengthening reinforced concrete beams using fiber
Strengthening reinforced concrete beams using fiberMJ NavaneethaKannan
 
IRJET- Finite Element Analysis of Retrofitting of RC Beam with CFRP using Abaqus
IRJET- Finite Element Analysis of Retrofitting of RC Beam with CFRP using AbaqusIRJET- Finite Element Analysis of Retrofitting of RC Beam with CFRP using Abaqus
IRJET- Finite Element Analysis of Retrofitting of RC Beam with CFRP using AbaqusIRJET Journal
 
211.5 r 96 - guide for submittal of concrete proportions
211.5 r 96 - guide for submittal of concrete proportions211.5 r 96 - guide for submittal of concrete proportions
211.5 r 96 - guide for submittal of concrete proportionsMOHAMMED SABBAR
 
IRJET- Experimental and Analytical Investigation of Fiber Reinforced Polymer ...
IRJET- Experimental and Analytical Investigation of Fiber Reinforced Polymer ...IRJET- Experimental and Analytical Investigation of Fiber Reinforced Polymer ...
IRJET- Experimental and Analytical Investigation of Fiber Reinforced Polymer ...IRJET Journal
 
IRJET- An Experimental Study on Strengthening of RCC Beam using Waste PVC Fle...
IRJET- An Experimental Study on Strengthening of RCC Beam using Waste PVC Fle...IRJET- An Experimental Study on Strengthening of RCC Beam using Waste PVC Fle...
IRJET- An Experimental Study on Strengthening of RCC Beam using Waste PVC Fle...IRJET Journal
 
REHABILITATION METHOD OF BEAM COLUMN JOINT USNG NANO COMPOSITE FERROCEMENT JA...
REHABILITATION METHOD OF BEAM COLUMN JOINT USNG NANO COMPOSITE FERROCEMENT JA...REHABILITATION METHOD OF BEAM COLUMN JOINT USNG NANO COMPOSITE FERROCEMENT JA...
REHABILITATION METHOD OF BEAM COLUMN JOINT USNG NANO COMPOSITE FERROCEMENT JA...IRJET Journal
 
IRJET- External Strengthening of Reinforced Concrete Column with CFRP
IRJET-  	  External Strengthening of Reinforced Concrete Column with CFRPIRJET-  	  External Strengthening of Reinforced Concrete Column with CFRP
IRJET- External Strengthening of Reinforced Concrete Column with CFRPIRJET Journal
 
IRJET- External Strengthening of Reinforced Concrete Column with CFRP
IRJET-  	  External Strengthening of Reinforced Concrete Column with CFRPIRJET-  	  External Strengthening of Reinforced Concrete Column with CFRP
IRJET- External Strengthening of Reinforced Concrete Column with CFRPIRJET Journal
 
IRJET- Flexural Behaviour of Reinforced Concrete Beams Retrofitted with Fibre...
IRJET- Flexural Behaviour of Reinforced Concrete Beams Retrofitted with Fibre...IRJET- Flexural Behaviour of Reinforced Concrete Beams Retrofitted with Fibre...
IRJET- Flexural Behaviour of Reinforced Concrete Beams Retrofitted with Fibre...IRJET Journal
 
a360-16-spec-and-commentary_march-2021.pdf
a360-16-spec-and-commentary_march-2021.pdfa360-16-spec-and-commentary_march-2021.pdf
a360-16-spec-and-commentary_march-2021.pdfRafael Pretel
 
IRJET- Review on Retrofitting by using Fibre Reinforced Polymer
IRJET- Review on Retrofitting by using Fibre Reinforced PolymerIRJET- Review on Retrofitting by using Fibre Reinforced Polymer
IRJET- Review on Retrofitting by using Fibre Reinforced PolymerIRJET Journal
 

Similar to Reinforced concrete (20)

Design considerations for_steel_fiber_re
Design considerations for_steel_fiber_reDesign considerations for_steel_fiber_re
Design considerations for_steel_fiber_re
 
IRJET- Behavior of RC T-Beam Strengthen using Basalt Fiber Reinforced Pol...
IRJET-  	  Behavior of RC T-Beam Strengthen using Basalt Fiber Reinforced Pol...IRJET-  	  Behavior of RC T-Beam Strengthen using Basalt Fiber Reinforced Pol...
IRJET- Behavior of RC T-Beam Strengthen using Basalt Fiber Reinforced Pol...
 
ACI 347R-14_Guía de encofrados para hormigón.pdf
ACI 347R-14_Guía de encofrados para hormigón.pdfACI 347R-14_Guía de encofrados para hormigón.pdf
ACI 347R-14_Guía de encofrados para hormigón.pdf
 
COMPARATIVE AND EXPERIMENTAL INVESTIGATION OF E -GLASS AND S-GLASS ARECA BANA...
COMPARATIVE AND EXPERIMENTAL INVESTIGATION OF E -GLASS AND S-GLASS ARECA BANA...COMPARATIVE AND EXPERIMENTAL INVESTIGATION OF E -GLASS AND S-GLASS ARECA BANA...
COMPARATIVE AND EXPERIMENTAL INVESTIGATION OF E -GLASS AND S-GLASS ARECA BANA...
 
Aci 550.2-r13
Aci 550.2-r13Aci 550.2-r13
Aci 550.2-r13
 
IRJET- EBR and GM Methods for External Flexural Strengthening of RC Beams
IRJET-  	  EBR and GM Methods for External Flexural Strengthening of RC BeamsIRJET-  	  EBR and GM Methods for External Flexural Strengthening of RC Beams
IRJET- EBR and GM Methods for External Flexural Strengthening of RC Beams
 
Aci 355.4 m
Aci 355.4 mAci 355.4 m
Aci 355.4 m
 
IRJET- Experimental Study on Retrofitted RC- Beams
IRJET- Experimental Study on Retrofitted RC- BeamsIRJET- Experimental Study on Retrofitted RC- Beams
IRJET- Experimental Study on Retrofitted RC- Beams
 
Strengthening reinforced concrete beams using fiber
Strengthening reinforced concrete beams using fiberStrengthening reinforced concrete beams using fiber
Strengthening reinforced concrete beams using fiber
 
IRJET- Finite Element Analysis of Retrofitting of RC Beam with CFRP using Abaqus
IRJET- Finite Element Analysis of Retrofitting of RC Beam with CFRP using AbaqusIRJET- Finite Element Analysis of Retrofitting of RC Beam with CFRP using Abaqus
IRJET- Finite Element Analysis of Retrofitting of RC Beam with CFRP using Abaqus
 
211.5 r 96 - guide for submittal of concrete proportions
211.5 r 96 - guide for submittal of concrete proportions211.5 r 96 - guide for submittal of concrete proportions
211.5 r 96 - guide for submittal of concrete proportions
 
IRJET- Experimental and Analytical Investigation of Fiber Reinforced Polymer ...
IRJET- Experimental and Analytical Investigation of Fiber Reinforced Polymer ...IRJET- Experimental and Analytical Investigation of Fiber Reinforced Polymer ...
IRJET- Experimental and Analytical Investigation of Fiber Reinforced Polymer ...
 
IRJET- An Experimental Study on Strengthening of RCC Beam using Waste PVC Fle...
IRJET- An Experimental Study on Strengthening of RCC Beam using Waste PVC Fle...IRJET- An Experimental Study on Strengthening of RCC Beam using Waste PVC Fle...
IRJET- An Experimental Study on Strengthening of RCC Beam using Waste PVC Fle...
 
REHABILITATION METHOD OF BEAM COLUMN JOINT USNG NANO COMPOSITE FERROCEMENT JA...
REHABILITATION METHOD OF BEAM COLUMN JOINT USNG NANO COMPOSITE FERROCEMENT JA...REHABILITATION METHOD OF BEAM COLUMN JOINT USNG NANO COMPOSITE FERROCEMENT JA...
REHABILITATION METHOD OF BEAM COLUMN JOINT USNG NANO COMPOSITE FERROCEMENT JA...
 
J43025258
J43025258J43025258
J43025258
 
IRJET- External Strengthening of Reinforced Concrete Column with CFRP
IRJET-  	  External Strengthening of Reinforced Concrete Column with CFRPIRJET-  	  External Strengthening of Reinforced Concrete Column with CFRP
IRJET- External Strengthening of Reinforced Concrete Column with CFRP
 
IRJET- External Strengthening of Reinforced Concrete Column with CFRP
IRJET-  	  External Strengthening of Reinforced Concrete Column with CFRPIRJET-  	  External Strengthening of Reinforced Concrete Column with CFRP
IRJET- External Strengthening of Reinforced Concrete Column with CFRP
 
IRJET- Flexural Behaviour of Reinforced Concrete Beams Retrofitted with Fibre...
IRJET- Flexural Behaviour of Reinforced Concrete Beams Retrofitted with Fibre...IRJET- Flexural Behaviour of Reinforced Concrete Beams Retrofitted with Fibre...
IRJET- Flexural Behaviour of Reinforced Concrete Beams Retrofitted with Fibre...
 
a360-16-spec-and-commentary_march-2021.pdf
a360-16-spec-and-commentary_march-2021.pdfa360-16-spec-and-commentary_march-2021.pdf
a360-16-spec-and-commentary_march-2021.pdf
 
IRJET- Review on Retrofitting by using Fibre Reinforced Polymer
IRJET- Review on Retrofitting by using Fibre Reinforced PolymerIRJET- Review on Retrofitting by using Fibre Reinforced Polymer
IRJET- Review on Retrofitting by using Fibre Reinforced Polymer
 

Recently uploaded

Hubble Asteroid Hunter III. Physical properties of newly found asteroids
Hubble Asteroid Hunter III. Physical properties of newly found asteroidsHubble Asteroid Hunter III. Physical properties of newly found asteroids
Hubble Asteroid Hunter III. Physical properties of newly found asteroidsSérgio Sacani
 
Biological Classification BioHack (3).pdf
Biological Classification BioHack (3).pdfBiological Classification BioHack (3).pdf
Biological Classification BioHack (3).pdfmuntazimhurra
 
Recombinant DNA technology (Immunological screening)
Recombinant DNA technology (Immunological screening)Recombinant DNA technology (Immunological screening)
Recombinant DNA technology (Immunological screening)PraveenaKalaiselvan1
 
9654467111 Call Girls In Raj Nagar Delhi Short 1500 Night 6000
9654467111 Call Girls In Raj Nagar Delhi Short 1500 Night 60009654467111 Call Girls In Raj Nagar Delhi Short 1500 Night 6000
9654467111 Call Girls In Raj Nagar Delhi Short 1500 Night 6000Sapana Sha
 
Botany 4th semester series (krishna).pdf
Botany 4th semester series (krishna).pdfBotany 4th semester series (krishna).pdf
Botany 4th semester series (krishna).pdfSumit Kumar yadav
 
Formation of low mass protostars and their circumstellar disks
Formation of low mass protostars and their circumstellar disksFormation of low mass protostars and their circumstellar disks
Formation of low mass protostars and their circumstellar disksSérgio Sacani
 
Stunning ➥8448380779▻ Call Girls In Panchshil Enclave Delhi NCR
Stunning ➥8448380779▻ Call Girls In Panchshil Enclave Delhi NCRStunning ➥8448380779▻ Call Girls In Panchshil Enclave Delhi NCR
Stunning ➥8448380779▻ Call Girls In Panchshil Enclave Delhi NCRDelhi Call girls
 
GBSN - Microbiology (Unit 2)
GBSN - Microbiology (Unit 2)GBSN - Microbiology (Unit 2)
GBSN - Microbiology (Unit 2)Areesha Ahmad
 
Biopesticide (2).pptx .This slides helps to know the different types of biop...
Biopesticide (2).pptx  .This slides helps to know the different types of biop...Biopesticide (2).pptx  .This slides helps to know the different types of biop...
Biopesticide (2).pptx .This slides helps to know the different types of biop...RohitNehra6
 
Asymmetry in the atmosphere of the ultra-hot Jupiter WASP-76 b
Asymmetry in the atmosphere of the ultra-hot Jupiter WASP-76 bAsymmetry in the atmosphere of the ultra-hot Jupiter WASP-76 b
Asymmetry in the atmosphere of the ultra-hot Jupiter WASP-76 bSérgio Sacani
 
Forensic Biology & Its biological significance.pdf
Forensic Biology & Its biological significance.pdfForensic Biology & Its biological significance.pdf
Forensic Biology & Its biological significance.pdfrohankumarsinghrore1
 
Isotopic evidence of long-lived volcanism on Io
Isotopic evidence of long-lived volcanism on IoIsotopic evidence of long-lived volcanism on Io
Isotopic evidence of long-lived volcanism on IoSérgio Sacani
 
Green chemistry and Sustainable development.pptx
Green chemistry  and Sustainable development.pptxGreen chemistry  and Sustainable development.pptx
Green chemistry and Sustainable development.pptxRajatChauhan518211
 
fundamental of entomology all in one topics of entomology
fundamental of entomology all in one topics of entomologyfundamental of entomology all in one topics of entomology
fundamental of entomology all in one topics of entomologyDrAnita Sharma
 
Natural Polymer Based Nanomaterials
Natural Polymer Based NanomaterialsNatural Polymer Based Nanomaterials
Natural Polymer Based NanomaterialsAArockiyaNisha
 
Raman spectroscopy.pptx M Pharm, M Sc, Advanced Spectral Analysis
Raman spectroscopy.pptx M Pharm, M Sc, Advanced Spectral AnalysisRaman spectroscopy.pptx M Pharm, M Sc, Advanced Spectral Analysis
Raman spectroscopy.pptx M Pharm, M Sc, Advanced Spectral AnalysisDiwakar Mishra
 
GBSN - Microbiology (Unit 1)
GBSN - Microbiology (Unit 1)GBSN - Microbiology (Unit 1)
GBSN - Microbiology (Unit 1)Areesha Ahmad
 
Unlocking the Potential: Deep dive into ocean of Ceramic Magnets.pptx
Unlocking  the Potential: Deep dive into ocean of Ceramic Magnets.pptxUnlocking  the Potential: Deep dive into ocean of Ceramic Magnets.pptx
Unlocking the Potential: Deep dive into ocean of Ceramic Magnets.pptxanandsmhk
 
All-domain Anomaly Resolution Office U.S. Department of Defense (U) Case: “Eg...
All-domain Anomaly Resolution Office U.S. Department of Defense (U) Case: “Eg...All-domain Anomaly Resolution Office U.S. Department of Defense (U) Case: “Eg...
All-domain Anomaly Resolution Office U.S. Department of Defense (U) Case: “Eg...Sérgio Sacani
 

Recently uploaded (20)

Hubble Asteroid Hunter III. Physical properties of newly found asteroids
Hubble Asteroid Hunter III. Physical properties of newly found asteroidsHubble Asteroid Hunter III. Physical properties of newly found asteroids
Hubble Asteroid Hunter III. Physical properties of newly found asteroids
 
Biological Classification BioHack (3).pdf
Biological Classification BioHack (3).pdfBiological Classification BioHack (3).pdf
Biological Classification BioHack (3).pdf
 
CELL -Structural and Functional unit of life.pdf
CELL -Structural and Functional unit of life.pdfCELL -Structural and Functional unit of life.pdf
CELL -Structural and Functional unit of life.pdf
 
Recombinant DNA technology (Immunological screening)
Recombinant DNA technology (Immunological screening)Recombinant DNA technology (Immunological screening)
Recombinant DNA technology (Immunological screening)
 
9654467111 Call Girls In Raj Nagar Delhi Short 1500 Night 6000
9654467111 Call Girls In Raj Nagar Delhi Short 1500 Night 60009654467111 Call Girls In Raj Nagar Delhi Short 1500 Night 6000
9654467111 Call Girls In Raj Nagar Delhi Short 1500 Night 6000
 
Botany 4th semester series (krishna).pdf
Botany 4th semester series (krishna).pdfBotany 4th semester series (krishna).pdf
Botany 4th semester series (krishna).pdf
 
Formation of low mass protostars and their circumstellar disks
Formation of low mass protostars and their circumstellar disksFormation of low mass protostars and their circumstellar disks
Formation of low mass protostars and their circumstellar disks
 
Stunning ➥8448380779▻ Call Girls In Panchshil Enclave Delhi NCR
Stunning ➥8448380779▻ Call Girls In Panchshil Enclave Delhi NCRStunning ➥8448380779▻ Call Girls In Panchshil Enclave Delhi NCR
Stunning ➥8448380779▻ Call Girls In Panchshil Enclave Delhi NCR
 
GBSN - Microbiology (Unit 2)
GBSN - Microbiology (Unit 2)GBSN - Microbiology (Unit 2)
GBSN - Microbiology (Unit 2)
 
Biopesticide (2).pptx .This slides helps to know the different types of biop...
Biopesticide (2).pptx  .This slides helps to know the different types of biop...Biopesticide (2).pptx  .This slides helps to know the different types of biop...
Biopesticide (2).pptx .This slides helps to know the different types of biop...
 
Asymmetry in the atmosphere of the ultra-hot Jupiter WASP-76 b
Asymmetry in the atmosphere of the ultra-hot Jupiter WASP-76 bAsymmetry in the atmosphere of the ultra-hot Jupiter WASP-76 b
Asymmetry in the atmosphere of the ultra-hot Jupiter WASP-76 b
 
Forensic Biology & Its biological significance.pdf
Forensic Biology & Its biological significance.pdfForensic Biology & Its biological significance.pdf
Forensic Biology & Its biological significance.pdf
 
Isotopic evidence of long-lived volcanism on Io
Isotopic evidence of long-lived volcanism on IoIsotopic evidence of long-lived volcanism on Io
Isotopic evidence of long-lived volcanism on Io
 
Green chemistry and Sustainable development.pptx
Green chemistry  and Sustainable development.pptxGreen chemistry  and Sustainable development.pptx
Green chemistry and Sustainable development.pptx
 
fundamental of entomology all in one topics of entomology
fundamental of entomology all in one topics of entomologyfundamental of entomology all in one topics of entomology
fundamental of entomology all in one topics of entomology
 
Natural Polymer Based Nanomaterials
Natural Polymer Based NanomaterialsNatural Polymer Based Nanomaterials
Natural Polymer Based Nanomaterials
 
Raman spectroscopy.pptx M Pharm, M Sc, Advanced Spectral Analysis
Raman spectroscopy.pptx M Pharm, M Sc, Advanced Spectral AnalysisRaman spectroscopy.pptx M Pharm, M Sc, Advanced Spectral Analysis
Raman spectroscopy.pptx M Pharm, M Sc, Advanced Spectral Analysis
 
GBSN - Microbiology (Unit 1)
GBSN - Microbiology (Unit 1)GBSN - Microbiology (Unit 1)
GBSN - Microbiology (Unit 1)
 
Unlocking the Potential: Deep dive into ocean of Ceramic Magnets.pptx
Unlocking  the Potential: Deep dive into ocean of Ceramic Magnets.pptxUnlocking  the Potential: Deep dive into ocean of Ceramic Magnets.pptx
Unlocking the Potential: Deep dive into ocean of Ceramic Magnets.pptx
 
All-domain Anomaly Resolution Office U.S. Department of Defense (U) Case: “Eg...
All-domain Anomaly Resolution Office U.S. Department of Defense (U) Case: “Eg...All-domain Anomaly Resolution Office U.S. Department of Defense (U) Case: “Eg...
All-domain Anomaly Resolution Office U.S. Department of Defense (U) Case: “Eg...
 

Reinforced concrete

  • 1. Guide for the Design and Construction of Externally Bonded FRP Systems for Strengthening Concrete Structures Reported by ACI Committee 440 ACI encourages the development and appropriate use of new and emerging technologies com through the publication of the Emerging Technology Series. This series presents information and recommendations based on available test data, technical reports, limited experience with field applications, and the opinions of committee members. The presented information and recommendations, and their basis, may be less fully de-veloped and tested than those for more mature technologies. This report identifies areas in which information is believed to be less fully de-veloped, and describes research needs. The professional using this document should understand the limitations of this document and exercise judgment as to the appropriate application of this emerging technology. Charles E. Bakis Ali Ganjehlou Damian I. Kachlakev Morris Schupack P. N. Balaguru Duane J. Gee Vistasp M. Karbhari David W. Scott Craig A. Ballinger T. Russell Gentry Howard S. Kliger Rajan Sen Lawrence C. Bank Arie Gerritse James G. Korff Mohsen A. Shahawy Abdeldjelil Belarbi Karl Gillette Michael W. Lee Carol K. Shield Brahim Benmokrane William J. Gold* Ibrahim Mahfouz Khaled A. Soudki Gregg J. Blaszak* Charles H. Goodspeed, III Henry N. Marsh, Jr. Luc R. Taerwe Gordon L. Brown, Jr. Nabil F. Grace Orange S. Marshall Jay Thomas Vicki L. Brown Mark F. Green Amir Mirmiran Houssam A. Toutanji Thomas I. Campbell afzir.Mark E. Greenwood Ayman S. Mosallam Taketo Uomoto Charles W. Dolan Doug D. Gremel Antoine E. Naaman Miroslav Vadovic Dat Duthinh Michael S. Guglielmo Antonio Nanni David R. Vanderpool Rami M. Elhassan Issam E. Harik Kenneth Neale Milan Vatovec Salem S. Faza Mark P. Henderson Edward F. O’Neil, III Stephanie L. Walkup Edward R. Fyfe Bohdan N. Horeczko Max L. Porter David White www.David M. Gale Srinivasa L. Iyer ACI Committee Reports, Guides, Standard Practices, and Commentaries are intended for guidance in plan-ning, designing, executing, and inspecting construction. This document is intended for the use of individuals who are competent to evaluate the significance and limita-tions of its content and recommendations and who will accept responsibility for the application of the material it contains. The American Concrete Institute disclaims any and all responsibility for the stated principles. The Institute shall not be liable for any loss or damage arising therefrom. Reference to this document shall not be made in con-tract documents. If items found in this document are de-sired ACI 440.2R-02 became effective July 11, 2002. by the Architect/Engineer to be a part of the Copyright Ó 2002, American Concrete Institute. contract documents, they shall be restated in mandatory All rights reserved including rights of reproduction and use in any form or by any means, including the making of copies by any photo process, or by electronic or language for incorporation by the Architect/Engineer. mechanical device, printed, written, or oral, or recording for sound or visual reproduction or for use in any knowledge or retrieval system or device, unless permission in writing is obtained from the copyright proprietors. 440.2R-1 ACI 440.2R-02 Fiber-reinforced polymer (FRP) systems for strengthening concrete structures have emerged as an alternative to traditional strengthening techniques, such as steel plate bonding, section enlargement, and external post-tensioning. FRP strengthening systems use FRP composite materials as supplemental externally bonded reinforcement. FRP systems offer advantages over traditional strengthening techniques: they are lightweight, relatively easy to install, and are noncorrosive. Due to the characteristics of FRP materials, the behavior of FRP strengthened members, and various issues regarding the use of externally bonded reinforcement, specific guidance on the use of these systems is needed. This document offers general information on the history and use of FRP strengthening systems; a description of the unique material properties of FRP; and committee recommendations on the engineering, construction, and inspection of FRP systems used to strengthen concrete structures. The proposed guidelines are based on the knowledge gained from worldwide experimental research, analytical work, and field applications of FRP systems used to strengthen concrete structures. Keywords: aramid fibers; bridges; buildings; carbon fibers; concrete; corro-sion; crack widths; cracking; cyclic loading; deflections; development length; earthquake-resistant; fatigue; fiber-reinforced polymers; flexure; glass fiber; shear; stresses; structural analysis; structural design; time-dependent; torsion. CONTENTS PART 1—GENERAL Chapter 1—Introduction, p. 440.2R-2 1.1—Scope and limitations 1.2—Applications and use 1.3—Use of proprietary FRP systems 1.4—Definitions and acronyms 1.5—Notation Sami H. Rizkalla Chair John P. Busel Secretary *Co-chairs of the subcommittee that prepared this document. Note: The committee acknowledges the contribution of associate member Paul Kelley.
  • 2. 440.2R-2 ACI COMMITTEE REPORT Chapter 2—Background information, p. 440.2R-8 10.3—com Nominal shear strength 2.1—Historical development 10.4—FRP system contribution to shear strength 2.2—Commercially available externally bonded FRP systems Chapter 11—Axial compression, tension, and PART 2—MATERIALS ductility enhancement, p. 440.2R-27 Chapter 3—Constituent materials and properties, 11.1—Axial compression pp. 440.2R-9 11.2—Tensile strengthening 3.1—Constituent materials 11.3—Ductility 3.2—Physical properties 3.3—Mechanical properties and behavior Chapter 12—Reinforcement details, p. 440.2R-29 3.4—Time-dependent behavior 12.1—Bond and delamination 3.5—Durability 12.2—Detailing of laps and splices 3.6—FRP system qualification Chapter 13—Drawings, specifications, and PART 3—RECOMMENDED CONSTRUCTION submittals, p. 440.2R-30 REQUIREMENTS 13.1—Engineering requirements Chapter 4—Shipping, storage, and handling, pp. 440.2R-12 13.2—Drawings and specifications 4.1—Shipping 13.3—Submittals 4.2—Storage 4.3—Handling PART 5—DESIGN EXAMPLES Chapter 14—Design examples, p. 440.2R-31 14.1—Calculation of FRP system tensile strength Chapter 5—Installation, p. 440.2R-13 5.1—Contractor competency afzir.14.2—Calculation of FRP system tensile strength 5.2—Temperature, humidity, and moisture considerations 14.3—Flexural strengthening of an interior beam 5.3—Equipment 14.4—Shear strengthening of an interior T-beam 5.4—Substrate repair and surface preparation 14.5—Shear strengthening of an exterior column 5.5—Mixing of resins 5.6—Application of constituent materials Chapter 15—References, p. 440.2R-40 5.7—Alignment of FRP materials 15.1—Referenced standards and reports 5.8—Multiple plies and lap splices 15.2—Cited references 5.9—Curing of resins 15.3—Other references 5.10—Temporary protection www.APPENDIXES Chapter 6—Inspection, evaluation, and Appendix A—Material properties of carbon, glass, acceptance, pp. 440.2R-16 and aramid fibers, p. 440.2R-44 6.1—Inspection 6.2—Evaluation and acceptance Appendix B—Summary of standard test methods, p. 440.2R-44 Chapter 7—Maintenance and repair, p. 440.2R-17 7.1—General Appendix C—Areas of future research, p. 440.2R-45 7.2—Inspection and assessment 7.3—Repair of strengthening system PART 1—GENERAL 7.4—Repair of surface coating CHAPTER 1—INTRODUCTION The strengthening or retrofitting of existing concrete PART 4—DESIGN RECOMMENDATIONS structures to resist higher design loads, correct deterioration-related Chapter 8—General design considerations, damage, or increase ductility has traditionally been p. 440.2R-18 accomplished using conventional materials and construction 8.1—Design philosophy techniques. Externally bonded steel plates, steel or concrete 8.2—Strengthening limits jackets, and external post-tensioning are just some of the 8.3—Selection of FRP systems many traditional techniques available. 8.4—Design material properties Composite materials made of fibers in a polymeric resin, also known as fiber-reinforced polymers (FRP), have Chapter 9—Flexural strengthening, p. 440.2R-21 emerged as an alternative to traditional materials and tech-niques. 9.1—General considerations For the purposes of this document, an FRP system is 9.2—Nominal strength defined as all the fibers and resins used to create the composite 9.3—Ductility laminate, all applicable resins used to bond it to the concrete 9.4—Serviceability substrate, and all applied coatings used to protect the constituent 9.5—Creep-rupture and fatigue stress limits materials. Coatings used exclusively for aesthetic reasons are 9.6—Application to a singly reinforced rectangular section not considered part of an FRP system. FRP materials are lightweight, noncorrosive, and exhibit Chapter 10—Shear strengthening, pp. 440.2R-25 high tensile strength. Additionally, these materials are readily 10.1—General considerations available in several forms ranging from factory-made laminates 10.2—Wrapping schemes to dry fiber sheets that can be wrapped to conform to the
  • 3. DESIGN AND CONSTRUCTION OF EXTERNALLY BONDED FRP SYSTEMS 440.2R-3 geometry of a structure before adding the polymer resin. resins, or fiber/resin combinations for which this is not true. The relatively thin profile of cured FRP systems are often This document com currently does not have special provisions for desirable in applications where aesthetics or access is a concern. such materials. The growing interest in FRP systems for strengthening and Many issues regarding bond of the FRP system to the retrofitting can be attributed to many factors. Although the substrate remain the focus of a great deal of research. For fibers and resins used in FRP systems are relatively expensive both flexural and shear strengthening, there are many different compared to traditional strengthening materials like concrete varieties of debonding failure that can govern the strength of and steel, labor and equipment costs to install FRP systems an FRP-strengthened member. While most of the debonding are often lower. FRP systems can also be used in areas modes have been identified by researchers, more accurate with limited access where traditional techniques would methods of predicting debonding are still needed. Throughout be difficult to implement: for example, a slab shielded by pipe and conduit. the design procedures, significant limitations on the strain level The basis for this document is the knowledge gained from achieved in the FRP material (and thus the stress level worldwide experimental research, applications of FRP strengthening in this document are intended Areas where further research is needed this document and compiled in Appendix 1.1—Scope and limitations This document provides guidance and installation of FRP systems for concrete structures. Information afzir.analytical work, and field achieved) are imposed to conservatively account for debonding systems. The recommen-dations failure modes. It is envisioned that future development of to be conservative. these design procedures will include more thorough methods are highlighted in of predicting debonding. C. The document does give guidance on proper detailing and installation of FRP systems to prevent many types of debonding failure modes. Steps related to the surface preparation and for the selection, design, proper termination of the FRP system are vital in achieving externally strengthening the levels of strength predicted by the procedures in this on material properties, document. Some research has been conducted on various design, installation, quality control, and maintenance of FRP methods of anchoring FRP strengthening systems (by systems used as external reinforcement is presented. This mechanical or other means). It is important to recognize, information can be used to select an FRP system for increasing however, that methods of anchoring these systems are the strength and stiffness of reinforced concrete beams or the highly problematic due to the brittle, anisotropic nature ductility of columns, and other applications. of composite materials. Any proposed method of anchorage A significant body of research serves as the basis for this should be heavily scrutinized before field implementation. document. This research, conducted over the past 20 years, The design equations given in this document are the result of includes analytical studies, experimental work, and monitored research primarily conducted on moderately sized and field applications of FRP strengthening systems. Based on the available research, the design procedures outlined in this proportioned members. While FRP systems likely are effective www.document are considered to be conservative. It is important on other members, such as deep beams, this has not been to note, however, that the design procedures have not, in validated through testing. Caution should be given to applica-tions many cases, been thoroughly developed and proven. It is involving strengthening of very large members or envisioned that over time these procedures will be adapted to strengthening in disturbed regions (D-regions) of structural be more accurate. For the time being, it is important to members. Where warranted, specific limitations on the size of specifically point out the areas of the document that do still members to be strengthened are given in this document. require research. This document applies only to FRP strengthening systems The durability and long-term performance of FRP materials used as additional tensile reinforcement. It is currently not have been the subject of much research; however, this research recommended to use these systems as compressive reinforce-ment. remains ongoing. Long-term field data are not currently While FRP materials can support compressive stresses, available, and it is still difficult to accurately predict the life there are numerous issues surrounding the use of FRP for of FRP strengthening systems. The design guidelines in this compression. Microbuckling of fibers can occur if any resin document do account for environmental degradation and voids are present in the laminate, laminates themselves can long-term durability by suggesting reduction factors for buckle if not properly adhered or anchored to the substrate, various environments. Long-term fatigue and creep are and highly unreliable compressive strengths result from also addressed by stress limitations indicated in this document. misaligning fibers in the field. This document does not address These factors and limitations are considered to be conservative. the construction, quality control, and maintenance issues that As more research becomes available, however, these factors would be involved with the use of the material for this purpose, will be modified and the specific environmental conditions nor does it address the design concerns surrounding such and loading conditions to which they should apply will be better defined. Additionally, the coupling effect of environmen-tal applications. The use of the types of FRP strengthening conditions and loading conditions still requires further systems described in this document to resist compressive study. Caution is advised in applications where the FRP forces is strongly discouraged. system is subjected simultaneously to extreme environmental This document does not specifically address masonry and stress conditions. (concrete masonry units, brick, or clay tile) construction, The factors associated with the long-term durability of the including masonry walls. Research completed to date, FRP system do not affect the tensile modulus of the material however, has shown that FRP systems can be used to used for design. Generally, this is reasonable given that the strengthen masonry walls, and many of the guidelines contained tensile modulus of FRP materials is not affected by environ-mental in this document may be applicable (Triantafillou 1998b; conditions. There may be, however, specific fibers, Ehsani et al. 1997; and Marshall et al. 1999).
  • 4. 440.2R-4 ACI COMMITTEE REPORT 1.2—Applications and use Due to the low temperature resistance of most fiber-rein-forced FRP systems can be used to rehabilitate or restore the polymer materials, the strength of externally bonded strength of a deteriorated structural member, to retrofit or FRP systems is assumed to be lost completely in a fire. For strengthen a sound structural member to resist increased this reason, the structural member without the FRP system loads due to changes in use of the structure, or to address should com possess sufficient strength to resist all applicable design or construction errors. The engineer should determine loads during a fire. Specific guidance, including load if an FRP system is a suitable strengthening technique before combinations and a rational approach to calculating structural selecting the type of FRP system. fire endurance, is given in Part 4. To assess the suitability of an FRP system for a particular The fire endurance of FRP-strengthened concrete members application, the engineer should perform a condition assessment may be improved through the use of certain resins, coatings, of the existing structure including establishing its existing or other methods of fire protection, but these have not been load-carrying capacity, identifying deficiencies and their sufficiently demonstrated to insulate the FRP system from causes, and determining the condition of the concrete the temperatures reached during a fire. substrate. The overall evaluation field inspection, a review of documents, and a structural analysis ACI 364.1R. Existing construction afzir.should include a thorough 1.2.3 Maximum service temperature—The physical and existing design or as-built mechanical properties of the resin components of FRP systems in accordance with are influenced by temperature and degrade above their glass-transition documents for the temperature Tg. The Tg is the midpoint of the structure should be reviewed, including the design drawings, temperature range over which the resin changes from a project specifications, as-built information, field test reports, past hard brittle state to a softer plastic state. This change in repair documentation, and maintenance history documentation. state will degrade the properties of the cured laminates. The engineer should conduct a thorough field investigation of The Tg is unique to each FRP system and ranges from 140 the existing structure in accordance with ACI 437R or other to 180 F (60 to 82 C) for existing, commercially available applicable documents. The tensile strength of the concrete on FRP systems. The maximum service temperature of an surfaces where the FRP system may be installed should be FRP system should not exceed the Tg of the FRP system. evaluated by conducting a pull-off adhesion test in accordance The Tg for a particular FRP system can be obtained from with ACI 503R. In addition, field investigation should verify the system manufacturer. the following: 1.2.4 Minimum concrete substrate strength—FRP systems • Existing dimensions of the structural members; work on sound concrete and should not be considered for • Location, size, and cause of cracks and spalls; applications on structural members containing corroded • Location and extent of corrosion of reinforcing steel; reinforcing steel or deteriorated concrete unless the substrate is • Quantity and location of existing reinforcing steel; repaired in accordance with Section 5.4. Concrete distress, • In-place compressive strength of concrete; and deterioration, and corrosion of existing reinforcing steel www.• Soundness of the concrete, especially the concrete should be evaluated and addressed before the application of cover, in all areas where the FRP system is to be the FRP system. Concrete deterioration concerns include, bonded to the concrete. but are not limited to, alkali-silica reactions, delayed The load-carrying capacity of the existing structure should ettringite formation, carbonation, longitudinal cracking be based on the information gathered in the field investigation, around corroded reinforcing steel, and laminar cracking at the review of design calculations and drawings, and as the location of the steel reinforcement. determined by analytical or other suitable methods. Load The condition and strength of the substrate should be tests or other methods can be incorporated into the overall evaluated to determine its capacity for strengthening of the evaluation process if deemed appropriate. member with externally bonded FRP reinforcement. The The engineer should survey the available literature and bond between repair materials and original concrete should consult with FRP system manufacturers to ensure the selected satisfy the recommendations of ACI 503R or Section 3.1 of FRP system and protective coating are appropriate for the ICRI Guideline No. 03733. intended application. The existing concrete substrate strength is an important 1.2.1 Strengthening limits—Some engineers and system parameter for bond-critical applications, including flexure or manufacturers have recommended that the increase in the shear strengthening. It should possess the necessary strength load-carrying capacity of a member strengthened with an to develop the design stresses of the FRP system through FRP system be limited. The philosophy is that a loss of FRP bond. The substrate, including all bond surfaces between reinforcement should not cause member failure. Specific repaired areas and the original concrete, should have sufficient guidance, including load combinations for assessing member direct tensile and shear strength to transfer force to the FRP integrity after loss of the FRP system, is provided in Part 4. system. The tensile strength should be at least 200 psi (1.4 MPa) FRP systems used to increase the strength of an existing as determined by using a pull-off type adhesion test as in member should be designed in accordance with Part 4, which ACI 503R or ASTM D 4541. FRP systems should not be used includes a comprehensive discussion of load limitations, when the concrete substrate has a compressive strength ( fc¢ ) sound load paths, effects of temperature and environment on less than 2500 psi (17 MPa). Contact-critical applications, FRP systems, loading considerations, and effects of reinforcing such as column wrapping for confinement that rely only on steel corrosion on FRP system integrity. intimate contact between the FRP system and the concrete, are 1.2.2 Fire and life safety—FRP-strengthened structures not governed by this minimum value. Design stresses in the should comply with all applicable building and fire codes. FRP system are developed by deformation or dilation of the Smoke and flame spread ratings should be determined in concrete section in contact-critical applications. accordance with ASTM E 84. Coatings can be used to limit The application of FRP systems will not stop the ongoing smoke and flame spread. corrosion of existing reinforcing steel. If steel corrosion is
  • 5. DESIGN AND CONSTRUCTION OF EXTERNALLY BONDED FRP SYSTEMS 440.2R-5 evident or is degrading the concrete substrate, placement concrete com substrate and the FRP system. In general, contact-critical of FRP reinforcement is not recommended without arresting the applications consist of FRP systems that completely ongoing corrosion and repairing any degradation to the substrate. wrap around the perimeter of the section. For most contact-critical applications the FRP system is bonded to the concrete 1.3—Use of proprietary FRP systems to facilitate installation but does not rely on that bond to perform This document refers specifically to commercially as intended. Confinement of columns for seismic retrofit is an available, proprietary FRP systems consisting of fibers example of a contact-critical application. and resins combined in a specific manner and installed by Creep-rupture—The gradual, time-dependent reduction a specific method. These systems have been developed of tensile strength due to continuous loading that leads to through material characterization and structural testing. failure of the section. Untested combinations of fibers and resins could result in Cross-link—A chemical bond between polymer molecules. an unexpected range of properties as well as potential Note: an increased number of cross-links per polymer material incompatibilities. Any FRP system considered molecule increases strength and modulus at the expense for use should have sufficient test data demonstrating adequate of ductility. performance of the entire system afzir.in similar applications, Cure of FRP systems—The process of causing the irre-versible including its method of installation. change in the properties of a thermosetting resin by The use of FRP systems developed through material chemical reaction. Cure is typically accomplished by addition characterization and structural testing, including well-documented of curing (cross-linking) agents or initiators, with or without proprietary systems, is recommended. The heat and pressure. Full cure is the point at which a resin use of untested combinations of fibers and resins should be reaches the specified properties. Undercure is a condition avoided. A comprehensive set of test standards for FRP where specified properties have not been reached. systems is being developed by several organizations, including Curing agent—A catalytic or reactive agent that causes ASTM, ACI, ICRI, and the Intelligent Sensing for Innovative polymerization when added to a resin. Also called hardener Structures organization (ISIS). Available standards from these or initiator. organizations are outlined in Appendix B. Debonding—A separation at the interface between the substrate and the adherent material. 1.4—Definitions and acronyms Degradation—A decline in the quality of the mechanical The following definitions clarify terms pertaining to FRP properties of a material. that are not commonly used in the reinforced concrete practice. Delamination—A separation along a plane parallel to the These definitions are specific to this document and are not surface, as in the separation of the layers of the FRP laminate applicable to other ACI documents. from each other. AFRP—Aramid fiber-reinforced polymer. www.Batch—Quantity of material mixed at one time or in one Development length, FRP—The bonded distance required continuous process. for transfer of stresses from the concrete to the FRP so as to Binder—develop the strength of the FRP system. The development Chemical treatment applied to the random arrange-ment length is a function of the strength of the substrate and the of fibers to give integrity to mats, roving, and fabric. rigidity of the bonded FRP. Specific binders are utilized to promote chemical compatibility with the various laminating resins used. Durability, FRP—The ability of a material to resist Bond-critical applications—Applications of FRP systems weathering action, chemical attack, abrasion, and other for strengthening structural members that rely on bond to the conditions of service. concrete substrate; flexural and shear strengthening of E-glass—A family of glass with a calcium alumina beams and slabs are examples of bond-critical applications. borosilicate composition and a maximum alkali content of Catalyst—A substance that accelerates a chemical reaction 2.0%. A general-purpose fiber that is used in reinforced and enables it to proceed under conditions more mild than polymers. otherwise required and that is not, itself, permanently Epoxy—A thermosetting polymer that is the reaction product changed by the reaction. See Initiator or Hardener. of epoxy resin and an amino hardener. (See also Epoxy resin.) CFR—Code of Federal Regulations. Epoxy resin—A class of organic chemical-bonding systems CFRP—Carbon fiber-reinforced polymer (includes graphite used in the preparation of special coatings or adhesives for fiber-reinforced polymer). concrete as binders in epoxy-resin mortars and concretes. Composite—A combination of two or more constituent Fabric—Arrangement of fibers held together in two materials differing in form or composition on a macroscale. dimensions. A fabric can be woven, nonwoven, knitted, or Note: The constituents retain their identities; that is, they do stitched. Multiple layers of fabric may be stitched together. not dissolve or merge completely into one another, although Fabric architecture is the specific description of fibers, they act in concert. Normally, the components can be physically directions, and construction of the fabric. identified and exhibit an interface between one another. Fiber—Any fine thread-like natural or synthetic object of Concrete substrate—The existing concrete or any cemen-titious mineral or organic origin. Note: This term is generally used repair materials used to repair or replace the existing for materials whose length is at least 100 times its diameter. concrete. The substrate can consist entirely of existing concrete, Fiber, aramid—Highly oriented organic fiber derived entirely of repair materials, or of a combination of existing from polyamide incorporating into an aromatic ring structure. concrete and repair materials. The substrate includes the surface Fiber, carbon—Fiber produced by heating organic to which the FRP system is installed. precursor materials containing a substantial amount of Contact-critical applications—Applications of FRP carbon, such as rayon, polyacrylonitrile (PAN), or pitch systems that rely on continuous intimate contact between the in an inert environment.
  • 6. 440.2R-6 ACI COMMITTEE REPORT Fiber, glass—Fiber drawn from an inorganic product of Interlaminar shear—Shearing force tending to produce a fusion that has cooled without crystallizing. Types of glass relative displacement between two laminae in a laminate fibers include alkali resistant (AR-glass), general purpose along the plane of their interface. (E-glass), and high strength (S-glass). Laminate—One or more layers of fiber bound together in Fiber content—The amount of fiber present in a composite. a cured resin matrix. Note: This usually is expressed as a percentage volume fraction Layup—The process of placing the FRP reinforcing or weight fraction of the composite. material com in position for molding. Fiber fly—Short filaments that break off dry fiber tows or Mat—A fibrous material for reinforced polymer, consisting yarns during handling and become airborne; usually classified of randomly oriented chopped filaments, short fibers (with as a nuisance dust. or without a carrier fabric), or long random filaments loosely Fiberglass—A composite material consisting of glass fibers held together with a binder. in resin. Matrix—In the case of fiber-reinforced polymers, the Fiber-reinforced polymer (FRP)—A general term for a materials that serve to bind the fibers together, transfer load composite material that consists of a polymer matrix reinforced to the fibers, and protect them against environmental attack with cloth, mat, strands, or any other fiber form. See and damage due to handling. Composite. Monomer—An organic molecule of relatively low Fiber volume fraction—The afzir.ratio of the volume of fibers molecular weight that creates a solid polymer by reacting to the volume of the composite. with itself or other compounds of low molecular weight or both. Fiber weight fraction—The ratio of the weight of fibers MSDS—Material safety data sheet. to the weight of the composite. OSHA—Occupational Safety and Health Administration. Filament—See Fiber. PAN—Polyacrylonitrile, a precursor fiber used to make Filler—A relatively inert substance added to a resin to carbon fiber. alter its properties or to lower cost or density. Sometimes the Phenolic—A thermosetting resin produced by the condensa-tion term is used specifically to mean particulate additives. Also of an aromatic alcohol with an aldehyde, particularly of called extenders. phenol with formaldehyde. Fire retardant—Chemicals that are used to reduce the Pitch—Petroleum or coal tar precursor base used to make tendency of a resin to burn; these can be added to the resin or carbon fiber. coated on the surface of the FRP. Ply—A single layer of fabric or mat; multiple plies, when Flow—molded together, make up the laminate. The movement of uncured resin under pressure or Polyester—gravity loads. One of a large group of synthetic resins, mainly produced by the reaction of dibasic acids with dihydroxy FRP—Fiber reinforced polymer; formerly, fiber-reinforced alcohols; commonly prepared for application by mixing with plastic. www.a vinyl-group monomer and free-radical catalysts at ambient GFRP—Glass fiber-reinforced polymer. temperatures and used as binders for resin mortars and Glass fiber—An individual filament made by drawing or concretes, fiber laminates (mainly glass), adhesives, and the spinning molten glass through a fine orifice. A continuous like. Commonly referred to as “unsaturated polyester.” filament is a single glass fiber of great or indefinite length. A Polymer—A high molecular weight organic compound, staple fiber is a glass fiber of relatively short length, generally natural or synthetic, containing repeating units. less than 17 in. (0.43 m), the length related to the forming or Polymerization—The reaction in which two or more spinning process used. molecules of the same substance combine to form a compound Glass transition temperature (Tg)—The midpoint of the containing the same elements and in the same proportions but temperature range over which an amphoras material (such as of higher molecular weight. glass or a high polymer) changes from (or to) a brittle, vitreous Polyurethane—Reaction product of an isocyanate with state to (or from) a plastic state. any of a wide variety of other compounds containing an Grid, FRP—A two-dimensional (planar) or three-dimen-sional active hydrogen group; used to formulate tough, abrasion-resistant (spatial) rigid array of interconnected FRP bars that coatings. form a contiguous lattice that can be used to reinforce concrete. Postcuring, FRP—Additional elevated-temperature curing The lattice can be manufactured with integrally connected bars that increases the level of polymer cross-linking; final properties or made of mechanically connected individual bars. of the laminate or polymer are enhanced. Hardener—1) a chemical (including certain fluosilicates or Pot life—Time interval after preparation during which a sodium silicate) applied to concrete floors to reduce wear and liquid or plastic mixture is to be used. dusting; or 2) in a two-component adhesive or coating, the Prepreg—A fiber or fiber sheet material containing resin chemical component that causes the resin component to cure. that is advanced to a tacky consistency. Multiple plies of Impregnate—In fiber-reinforced polymers, to saturate prepreg are typically cured with applied heat and pressure; the fibers with resin. also preimpregnated fiber or sheet. Initiator—A source of free radicals, which are groups of Pultrusion—A continuous process for manufacturing atoms that have at least one unpaired electron, used to start composites that have a uniform cross-sectional shape. The the curing process for unsaturated polyester and vinyl ester process consists of pulling a fiber-reinforcing material resins. Peroxides are the most common source of free radicals. through a resin impregnation bath then through a shaping die See Catalyst. where the resin is subsequently cured. Interface—The boundary or surface between two different, Resin—Polymeric material that is rigid or semirigid at physically distinguishable media. On fibers, the contact area room temperature, usually with a melting point or glass between fibers and coating/sizing. transition temperature above room temperature.
  • 7. DESIGN u u * * AND CONSTRUCTION OF EXTERNALLY BONDED FRP SYSTEMS 440.2R-7 Resin content—The amount of resin in a laminate, expressed CE = environmental-reduction factor as either a percentage of total mass or total volume. d = distance from extreme compression fiber to the Roving—A number of yarns, strands, tows, or ends of neutral axis, in. (mm) fibers collected into a parallel bundle with little or no twist. df = com depth of FRP shear reinforcement as shown in Sheet, FRP—A dry, flexible ply used in wet layup FRP Fig. 10.2, in. (mm) systems. Unidirectional FRP sheets consist of continuous fibers aligned in one direction and held together in-plane to Ec = modulus of elasticity of concrete, psi (MPa) create a ply of finite width and length. Fabrics are also referred Ef = tensile modulus of elasticity of FRP, psi (MPa) to as sheets. See Fabric, Ply. Es = modulus of elasticity of steel, psi (MPa) Shelf life—The length of time packaged materials can be fc = compressive stress in concrete, psi (MPa) stored under specified conditions and remain usable. fc¢ = specified compressive strength of concrete, psi (MPa) Sizing—Surface treatment or coating applied to filaments Öfc¢ = square root of specified compressive strength of to improve the filament-to-resin bond and to impart processing concrete and durability attributes. afzir.fc= apparent compressive strength of confined concrete, Sustained stress—Stress caused by unfactored sustained psi (MPa) loads including dead loads and the sustained portion of the live load. ff = stress level in the FRP reinforcement, psi (MPa) Thermoset—Resin that is formed by cross-linking polymer ff,s = stress level in the FRP caused by a moment within chains. Note: A thermoset cannot be melted and recycled the elastic range of the member, psi (MPa) because the polymer chains form a three-dimensional network. ffe = effective stress in the FRP; stress level attained at Tow—An untwisted bundle of continuous filaments. section failure, psi (MPa) Vinyl ester—A thermosetting resin containing both vinyl ffu * = ultimate tensile strength of the FRP material as and ester components, and cured by additional polymerization reported by the manufacturer, psi (MPa) initiated by free-radical generation. Vinyl esters are used as ffu = design ultimate tensile strength of FRP, psi binders for fiber laminates and adhesives. (MPa) VOC—Volatile organic compounds; any compound of carbon, excluding carbon monoxide, carbon dioxide, carbonic ffu = mean ultimate strength of FRP based on a popu-lation acid, metallic carbides, or carbonates, and ammonium of 20 or more tensile tests per ASTM D carbonate, that participates in atmospheric photochemical 3039, psi (MPa) reactions, such as ozone depletion. fl = confining pressure due to FRP jacket, psi (MPa) Volume fraction—The proportion from 0.0 to 1.0 of a fs = stress in nonprestressed steel reinforcement, psi component within the composite, measured on a volume (MPa) www.basis, such as fiber-volume fraction. fs,s = stress level in nonprestressed steel reinforcement at Wet layup—A method of making a laminate product by service loads, psi (MPa) applying the resin system as a liquid when the fabric or mat fy = specified yield strength of nonprestressed steel is put in place. reinforcement, psi (MPa) Wet-out—The process of coating or impregnating roving, yarn, or fabric in which all voids between the strands and h = overall thickness of a member, in. (mm) filaments are filled with resin; it is also the condition at Icr = moment of inertia of cracked section transformed to which this state is achieved. concrete, in.4 (mm4) Witness panel—A small field sample FRP panel, manufac-tured k = ratio of the depth of the neutral axis to the reinforce-ment on-site in a noncritical area at conditions similar to the depth measured on the same side of neutral actual construction. The panel can be later tested to determine axis mechanical and physical properties to confirm expected kf = stiffness per unit width per ply of the FRP rein-forcement, properties of the installed FRP laminate. lb/in. (N/mm); kf = Ef tf Yarn—An assemblage of twisted filaments, fibers, or k1 = modification factor applied to kv to account for the strands, formed into a continuous length that is suitable for use in weaving textile materials. concrete strength k2 = modification factor applied to kv to account for the 1.5—Notation wrapping scheme Af = ntfwf , area of FRP external reinforcement, in.2 Le = active bond length of FRP laminate, in. (mm) (mm2) ldf = development length of FRP system, in. (mm) Afv = area of FRP shear reinforcement with spacing s, in.2 Mcr = cracking moment, in.-lb (N-mm) (mm2) Mn = nominal moment strength, in.-lb (N-mm) Ag = gross area of section, in.2 (mm2) Ms = moment within the elastic range of the member, As = area of nonprestressed steel reinforcement, in.2 in.-lb (N-mm) (mm2) Mu = factored moment at section, in.-lb (N-mm) Ast = total area of longitudinal reinforcement, in.2 (mm2) n = number of plies of FRP reinforcement b = width of rectangular cross section, in. (mm) pf= ultimate tensile strength per unit width per play of bw = web width or diameter of circular section, in. (mm) the FRP reinforcement, lb/in. (N/mm); pf=fftf c = distance from extreme compression fiber to the pfu = mean tensile strength per unit width per ply u * of the neutral axis, in. (mm) c reinforcement, lb/in. (N/¢ mm)
  • 8. 440.2R-u * 8 ACI COMMITTEE REPORT Pn = nominal axial load strength at given eccentricity, lb km = bond-dependent coefficient for flexure (N) kv = bond-dependent coefficient for shear r = radius of the edges of a square or rectangular section rf = FRP reinforcement ratio confined with FRP, in. (mm) rg = ratio of the area of longitudinal steel reinforcement to Rn = nominal strength of a member the cross-sectional area of a compression member Rnf = nominal strength of a member subjected to the rs = ratio of nonprestressed reinforcement elevated temperatures associated with a fire s = standard deviation SDL = dead load effects yf = com additional FRP strength-reduction factor sf = spacing FRP shear reinforcing as described in Fig. 10.2, in. (mm) CHAPTER 2—BACKGROUND INFORMATION SLL = live load effects Externally bonded FRP systems have been used to tf = nominal thickness of one ply of the FRP reinforce-ment, strengthen and retrofit existing concrete structures around in. (mm) afzir.the world since the mid 1980s. The number of projects Tg = glass-transition temperature, °F (°C) utilizing FRP systems worldwide has increased dramatically, Vc = nominal shear strength provided by concrete with from a few 10 years ago to several thousand today (Bakis et steel flexural reinforcement, lb (N) al. 2002). Structural elements strengthened with externally Vn = nominal shear strength, lb (N) bonded FRP systems include beams, slabs, columns, walls, Vs = nominal shear strength provided by steel stirrups, joints/connections, chimneys and smokestacks, vaults, domes, tunnels, silos, pipes, and trusses. Externally bonded lb (N) FRP systems have also been used to strengthen masonry, Vf = nominal shear strength provided by FRP stirrups, lb timber, steel, and cast-iron structures. The idea of strengthening wf = width of the FRP reinforcing plies, in. (mm) concrete structures with externally bonded reinforcement is not a = angle of inclination of stirrups or spirals, degrees new. Externally bonded FRP systems were developed as aL = longitudinal coefficient of thermal expansion, in./in./ alternates to traditional external reinforcing techniques like °F (mm/mm/°C) steel plate bonding and steel or concrete column jacketing. a= transverse coefficient of thermal expansion, in./in./°F The initial development of externally bonded FRP systems T (mm/mm/°C) for the retrofit of concrete structures occurred in the 1980s in bboth Europe and Japan. 1 = ratio of the depth of the equivalent rectangular stress block to the depth of the neutral axis e= strain level in the concrete substrate developed by a 2.1—Historical development b given bending moment (tension in positive), in./in. In Europe, FRP systems were developed as alternates to www.steel plate bonding. Bonding steel plates to the tension zones (mm/mm) of concrete members with epoxy resins were shown to be ebi = strain level in the concrete substrate at the time of the viable techniques for increasing their flexural strengths FRP installation (tension is positive), in./in. (mm/mm) (Fleming and King 1967). This technique has been used to ec = stain level in the concrete, in./in. (mm/mm) strengthen many bridges and buildings around the world. ec= maximum usable compressive strain of FRP confined Because steel plates can corrode, leading to a deterioration of concrete, in./in. (mm/mm) the bond between the steel and concrete, and that are difficult e= maximum usable compressive strain of concrete, in./ to install, requiring the use of heavy equipment, researchers cu in., (mm/mm) have looked to FRP materials as an alternative to steel. ef = strain level in the FRP reinforcement, in./in. (mm/ Experimental work using FRP materials for retrofitting mm) concrete structures was reported as early as 1978 in Germany e(Wolf and Miessler 1989). Research in Switzerland led to fe = effective strain level in FRP reinforcement; strain level the first applications of externally bonded FRP systems attained at section failure, in./in. (mm/mm) to reinforced concrete bridges for flexural strengthening efu = design rupture strain of FRP reinforcement, in./in. (Meier 1987; Rostasy 1987). (mm/mm) FRP systems were first applied to reinforced concrete efu = mean rupture stain of FRP reinforcement based on columns for providing additional confinement in Japan in a population of 20 or more tensile tests per the 1980s (Fardis and Khalili 1981; Katsumata et al. 1987). ASTM D 3039, in./in. (mm/mm) A sudden increase in the use of FRPs in Japan was observed eafter the 1995 Hyogoken Nanbu earthquake (Nanni 1995). f= ultimate rupture strain of the FRP reinforcement, in./in. (mm/mm) The United States has had a long and continuous interest es = strain level in the nonprestessed steel reinforcement, in fiber-based reinforcement for concrete structures since the in./in./ (mm) 1930s. Actual development and research into the use of these esy = strain corresponding to the yield strength of non-prestressed materials for retrofitting concrete structures, however, started in the 1980s through the initiatives of the National Science steel reinforcement Foundation (NSF) and the Federal Highway Administration f = strength reduction factor (FHWA). The research activities led to the construction of g = multiplier on fc¢ to determine the intensity of an many field projects encompassing a wide variety of environ-mental equivalent rectangular stress distribution for concrete conditions. Previous research and field applications ka = efficiency factor for FRP reinforcement (based on for FRP rehabilitation and strengthening are described in the section geometry) ACI 440R-96 and conference proceedings (Japan Concrete c ¢
  • 9. DESIGN AND CONSTRUCTION OF EXTERNALLY BONDED FRP SYSTEMS 440.2R-9 Institute 1997; Neale 2000; Dolan et al. 1999; Sheheta et al. 1. Preimpregnated 1999; Saadatmanesh and Ehsani 1998; Benmokrane and run predominantly Rahman 1998; Neale and Labossière 1997; Hassan and 2. Preimpregnated Rizkalla 2002). where the The development of codes and standards for externally and bonded FRP systems is ongoing in Europe, Japan, Canada, 3. Preimpregnated and the United States. Within the last 10 years, the Japan mechanically com unidirectional fiber sheets where the fibers in one planar direction; multidirectional fiber sheets or fabrics fibers are oriented in at least two planar directions; fiber tows that are wound or otherwise applied to the concrete surface. Society of Civil Engineers (JSCE) and the Japan Concrete 2.2.3 Precured systems—Precured FRP systems consist of Institute (JCI) and the Railway Technical Research Institute a wide variety of composite shapes manufactured off-site. (RTRI) published several documents related to the use of Typically, an adhesive along with the primer and putty is FRP materials in concrete structures. used to bond the precured shapes to the concrete surface. The In Europe, Task Group 9.3 of the International Federation system manufacturer should be consulted for recommended for Structural Concrete (FIB) recently published a bulletin installation procedures. Precured systems are analogous to on design guidelines for externally for reinforced concrete structures The Canada Standards Association afzir.bonded FRP reinforcement precast concrete. Three common types of precured systems (FIB 2001). are listed as follows: and ISIS have been 1. Precured unidirectional laminate sheets, typically delivered active in developing guidelines for FRP systems. Section 16, to the site in the form of large flat stock or as thin ribbon “Fiber Reinforced Concrete,” of the Canadian Highway strips coiled on a roll; Bridge Design Code was completed in 2000 (CSA S806-02) 2. Precured multidirectional grids, typically delivered to and the Canadian Standards Association (CSA) recently the site coiled on a roll; approved the code “Design and Construction of Building 3. Precured shells, typically delivered to the site in the Components with Fiber Reinforced Polymers” (CSA S806-02). form of shell segments cut longitudinally so they can be In the United States, criteria for evaluating FRP systems opened and fitted around columns or other members; multiple are becoming available to the construction industry (AC125 shell layers are bonded to the concrete and to each other to 1997; CALTRANS 1996; Hawkins et al. 1998). provide seismic confinement. 2.2.4 Other FRP forms—Other FRP forms are not covered 2.2—Commercially available externally bonded in this document. These include cured FRP rigid rod and FRP systems flexible strand or cable (Saadatmanesh and Tannous FRP systems come in a variety of forms, including wet 1999a; Dolan 1999; Fukuyama 1999; ACI 440R-96 and layup systems and precured systems. FRP system forms can ACI 440.1R-01). be categorized based on how they are delivered to the site and installed. The FRP system and its form should be selected PART 2—MATERIALS www.based on the acceptable transfer of structural loads and the CHAPTER 3—CONSTITUENT MATERIALS AND ease and simplicity of application. Common FRP system PROPERTIES forms suitable for the strengthening of structural members are The physical and mechanical properties of FRP materials listed as follows: presented in this chapter explain the behavior and properties 2.2.1 Wet layup systems—Wet layup FRP systems consist affecting their use in concrete structures. The effects of factors of dry unidirectional or multidirectional fiber sheets or fabrics such as loading history and duration, temperature, and moisture impregnated with a saturating resin on-site. The saturating on the properties of FRP are discussed. resin, along with the compatible primer and putty, is used to FRP-strengthening systems come in a variety of forms bond the FRP sheets to the concrete surface. Wet layup sys-tems (wet layup, prepreg, precured). Factors such as fiber volume, are saturated in-place and cured in-place and, in this type of fiber, type of resin, fiber orientation, dimensional sense, are analogous to cast-in-place concrete. Three common effects, and quality control during manufacturing all play a types of wet layup systems are listed as follows: role in establishing the characteristics of an FRP material. The 1. Dry unidirectional fiber sheets where the fibers run material characteristics described in this chapter are generic and predominantly in one planar direction; do not apply to all commercially available products. Standard 2. Dry multidirectional fiber sheets or fabrics where the test methods are being developed by several organizations fibers are oriented in at least two planar directions; and including ASTM, ACI, and ISIS to characterize certain FRP 3. Dry fiber tows that are wound or otherwise mechanically products. In the interim, however, the engineer is encouraged to applied to the concrete surface. The dry fiber tows are im-pregnated consult with the FRP system manufacturer to obtain the relevant with resin on-site during the winding operation. characteristics for a specific product and the applicability of 2.2.2 Prepreg systems—Prepreg FRP systems consist of those characteristics. uncured unidirectional or multidirectional fiber sheets or fabrics that are preimpregnated with a saturating resin in the 3.1—Constituent materials manufacturer’s facility. Prepreg systems are bonded to the The constituent materials used in commercially available concrete surface with or without an additional resin application, FRP repair systems, including all resins, primers, putties, depending upon specific system requirements. Prepreg saturants, adhesives, and fibers, have been developed for the systems are saturated off-site and, like wet layup systems, strengthening of structural concrete members based on cured in place. Prepreg systems usually require additional materials and structural testing. heating for curing. Prepreg system manufacturers should be 3.1.1 Resins—A wide range of polymeric resins, including consulted for storage and shelf-life recommendations and primers, putty fillers, saturants, and adhesives, are used with curing procedures. Three common types of prepreg FRP FRP systems. Commonly used resin types including epoxies, systems are listed as follows: vinyl esters, and polyesters have been formulated for use in
  • 10. 440.2R-10 ACI COMMITTEE REPORT Table 3.1—Typical densities of FRP materials, 3.2—com Physical properties lb/ft3 (g/cm3) 3.2.1 Density—FRP materials have densities ranging from 75 to 130 lb/ft3 (1.2 to 2.1 g/cm3), which is four to six times Steel GFRP CFRP AFRP lower than that of steel (Table 3.1). The reduced density 490 75 to 130 90 to 100 75 to 90 (7.9) (1.2 to 2.1) (1.5 to 1.6) (1.2 to 1.5) leads to lower transportation costs, reduces added dead load on the structure, and can ease handling of the materials on the project site. Table 3.2—Typical coefficients of thermal 3.2.2 Coefficient of thermal expansion—The coefficients expansion for FRP materials* of thermal expansion of unidirectional FRP materials differ ´ 10–6/°´ 10–6/°in the longitudinal and transverse directions, depending on Direction Coefficient of thermal expansion, F (C) the types of fiber, resin, and volume fraction of fiber. Table 3.2 GFRP CFRP AFRP lists the longitudinal and transverse coefficients of thermal Longitudinal, a3.3 to 5.6 –0.6 to 0 –3.3 to –1.1 L (6 to 10) (–1 to 0) (–6 to –2) expansion for typical unidirectional FRP materials. Note that 10.4 to 12.6 12 to 27 33 to 44 a negative coefficient of thermal expansion indicates that the Transverse, aT (19 to 23) (22 to 50) (60 to 80) material contracts with increased temperature and expands *afzir.with decreased temperature. For reference, concrete has a Typical values for fiber-volume fractions ranging from 0.5 to 0.7. coefficient of thermal expansion that varies from 4 ´ 10–6 to 10–6/°10–6 10–6/°a wide range of environmental conditions. FRP system 6 ´ F (7 ´ to 11 ´ C) and is usually assumed manufacturers use resins that have the following characteristics: to be isotropic (Mindess and Young 1981). Steel has an isotropic coefficient of thermal expansion of 6.5 ´ 10–6/°F • Compatibility with and adhesion to the concrete substrate; (11.7 ´ 10–6/°C). See Section 8.3.1 for design considerations • Compatibility with and adhesion to the FRP composite regarding thermal expansion. system; 3.2.3 Effects of high temperatures—Beyond the Tg, the • Resistance to environmental effects, including but not elastic modulus of a polymer is significantly reduced due to limited to moisture, salt water, temperature extremes, and changes in its molecular structure. The value of Tg depends chemicals normally associated with exposed concrete; on the type of resin but is normally in the region of 140 to • Filling ability; 180 °F (60 to 82 °C). In an FRP composite material, the fibers, • Workability; which exhibit better thermal properties than the resin, can • Pot life consistent with the application; continue to support some load in the longitudinal direction • Compatibility with and adhesion to the reinforcing until the temperature threshold of the fibers is reached. This fiber; and can occur at temperatures near 1800 °F (1000 °C) for glass • Development of appropriate mechanical properties for fibers and 350 °F (175 °C) for aramid fibers. Carbon fibers www.the FRP composite. are capable of resisting temperatures in excess of 500 °F (275 °C). Due to a reduction in force transfer between fibers 3.1.1.1 Primer—The primer is used to penetrate the through bond to the resin, however, the tensile properties of surface of the concrete, providing an improved adhesive the overall composite are reduced. Test results have indicated bond for the saturating resin or adhesive. that temperatures of 480 °F (250 °C), much higher than the 3.1.1.2 Putty fillers—The putty is used to fill small surface resin Tg, will reduce the tensile strength of GFRP and CFRP voids in the substrate, such as bug holes, and to provide a materials in excess of 20% (Kumahara et al. 1993). Other smooth surface to which the FRP system can bond. Filled properties affected by the shear transfer through the resin, surface voids also prevent bubbles from forming during such as bending strength, are reduced significantly at lower curing of the saturating resin. temperatures (Wang and Evans 1995). 3.1.1.3 Saturating resin—The saturating resin is used to For bond-critical applications of FRP systems, the properties impregnate the reinforcing fibers, fix them in place, and of the polymer at the fiber-concrete interface are essential in provide a shear load path to effectively transfer load between maintaining the bond between FRP and concrete. At a tempera-ture fibers. The saturating resin also serves as the adhesive for close to its Tg, however, the mechanical properties of the wet layup systems, providing a shear load path between the polymer are significantly reduced, and the polymer begins to previously primed concrete substrate and the FRP system. loose its ability to transfer stresses from the concrete to the fibers. 3.1.1.4 Adhesives—Adhesives are used to bond precured FRP laminate systems to the concrete substrate. The adhesive 3.3—Mechanical properties and behavior provides a shear load path between the concrete substrate and 3.3.1 Tensile behavior—When loaded in direct tension, the FRP reinforcing laminate. Adhesives are also used to bond FRP materials do not exhibit any plastic behavior (yielding) together multiple layers of precured FRP laminates. before rupture. The tensile behavior of FRP materials 3.1.1.5 Protective coatings—The protective coating is consisting of one type of fiber material is characterized by a used to protect the bonded FRP reinforcement from potentially linearly elastic stress-strain relationship until failure, which damaging environmental effects. Coatings are typically is sudden and can be catastrophic. applied to the exterior surface of the cured FRP system after The tensile strength and stiffness of an FRP material is the adhesive or saturating resin has cured. dependent on several factors. Because the fibers in an FRP 3.1.2 Fibers—Continuous glass, aramid, and carbon fibers material are the main load-carrying constituent, the type of are common reinforcements used with FRP systems. The fibers fiber, the orientation of the fibers, and the quantity of fibers give the FRP system its strength and stiffness. Typical ranges of primarily govern the tensile properties of the FRP material. the tensile properties of fibers are given in Appendix A. A more Due to the primary role of the fibers and methods of application, detailed description of fibers is given in ACI 440R. the properties of an FRP repair system are sometimes reported
  • 11. DESIGN AND CONSTRUCTION OF EXTERNALLY BONDED FRP SYSTEMS 440.2R-11 based on the net-fiber area. In other instances, the reported the fiber-com volume fraction, and the type of resin. Compressive properties are based on the gross-laminate area. strengths of 55, 78, and 20% of the tensile strength have been The gross-laminate area of an FRP system is calculated using reported for GFRP, CFRP, and AFRP, respectively (Wu the total cross-sectional area of the cured FRP system, including 1990). In general, compressive strengths are higher for all fibers and resin. The gross-laminate area is typically used materials with higher tensile strengths, except in the case for reporting precured laminate properties where the cured of AFRP where the fibers exhibit nonlinear behavior in thickness is constant and the relative proportion of fiber and compression at a relatively low level of stress. resin is controlled. The compressive modulus of elasticity is usually smaller The net-fiber area of an FRP system is calculated using the than the tensile modulus of elasticity of FRP materials. known area of fiber, neglecting the total width and thickness Test reports on samples containing a 55 to 60% volume fraction of the cured system; thus, resin is excluded. The net-fiber of continuous E-glass fibers in a matrix of vinyl ester or area is typically used for reporting properties of wet layup sys-tems isophthalic polyester resin have reported a compressive that use manufactured fiber sheets and field-installed modulus of elasticity of 5000 to 7000 ksi (34,000 to resins. The wet layup installation process leads to a con-trolled 48,000 MPa) (Wu 1990). According to reports, the compressive fiber content and a variable resin content. modulus of elasticity is approximately 80% for GFRP, 85% System properties reported using the gross-laminate area have for CFRP, and 100% for AFRP of the tensile modulus of higher relative thickness dimensions and lower relative strength elasticity for the same product (Ehsani 1993). and modulus values, whereas system properties reported using the net-fiber area have lower relative afzir.thickness dimensions and 3.4—Time-dependent behavior higher relative strength and modulus values. Regardless of the 3.4.1 Creep-rupture—FRP materials subjected to a constant basis for the reported values, the load-carrying strength (ffuAf) load over time can suddenly fail after a time period referred and stiffness (Af Ef) remain constant. (The calculation of FRP to as the endurance time. This type of failure is known as system properties using both gross-laminate and net-fiber creep-rupture. As the ratio of the sustained tensile stress to property methods is illustrated in Part 5.) Properties reported the short-term strength of the FRP laminate increases, endurance based on the net-fiber area are not the properties of the time decreases. The endurance time also decreases under bare fibers. The properties of an FRP system should be adverse environmental conditions, such as high temperature, characterized as a composite, recognizing not just the material ultraviolet-radiation exposure, high alkalinity, wet and dry properties of the individual fibers but also the efficiency of cycles, or freezing-and-thawing cycles. the fiber-resin system, the fabric architecture, and the method In general, carbon fibers are the least susceptible to creep-rupture; used to create the composite. The mechanical properties of all aramid fibers are moderately susceptible, and glass FRP systems, regardless of form, should be based on the testing fibers are most susceptible. Creep-rupture tests have been of laminate samples with a known fiber content. conducted on 0.25 in. (6 mm) diameter FRP bars reinforced www.The tensile properties of some commercially available with glass, aramid, and carbon fibers. The FRP bars were FRP strengthening systems are given in Appendix A. The tested at different load levels at room temperature. Results tensile properties of a particular FRP system, however, indicated that a linear relationship exists between creep-rupture should be obtained from the FRP system manufacturer. strength and the logarithm of time for all load levels. Manufacturers should report an ultimate tensile strength defined The ratios of stress level at creep-rupture after 500,000 h by this guide as the mean tensile strength of a sample of test (about 50 years) to the initial ultimate strength of the GFRP, specimens minus three times the standard deviation (ffu * = AFRP, and CFRP bars were extrapolated to be 0.3, 0.47, and ffu – 3s) and, similarly, report an ultimate rupture strain 0.91, respectively (Yamaguchi et al. 1997). Similar values (ef= eshave been determined elsewhere (Malvar 1998). fu – 3). These statistically based ultimate tensile properties provide a 99.87% probability that the indicated Recommendations on sustained stress limits imposed to values are exceeded (Mutsuyoshi et al. 1990). Young’s modulus avoid creep-rupture are given in the design section of this should be calculated as the chord modulus between 0.003 guide. As long as the sustained stress in the FRP is below the and 0.006 strain, in accordance with ASTM D 3039. A creep rupture stress limits, the strength of the FRP is available minimum number of 20 replicate test specimens should be for nonsustained loads. used to determine the ultimate tensile properties. The 3.4.2 Fatigue—A substantial amount of data for fatigue manufacturer should provide a description of the method behavior and life prediction of stand-alone FRP materials have used to obtain the reported tensile properties, including the been generated in the last 30 years (National Research Council number of tests, mean values, and standard deviations. 1991). During most of this period, aerospace materials were the 3.3.2 Compressive behavior—Externally bonded FRP primary subjects of investigation. Despite the differences in systems should not be used as compression reinforcement quality and consistency between aerospace and commercial-grade due to insufficient testing validating its use in this type of FRP materials, some general observations on the fatigue application. While it is not recommended to rely on externally behavior of FRP materials can be made. Unless specifically bonded FRP systems to resist compressive stresses, the stated otherwise, the following cases being reviewed are based following section is presented to fully characterize the on an unidirectional material with approximately 60% fiber-volume behavior of FRP materials. fraction and subjected to tension-tension sinusoidal Coupon tests on FRP laminates used for repair on concrete cyclic loading at: have shown that the compressive strength is lower than the • A frequency low enough to not cause self-heating; tensile strength (Wu 1990). The mode of failure for FRP • Ambient laboratory environments; laminates subjected to longitudinal compression can include • A stress ratio (ratio of minimum applied stress to transverse tensile failure, fiber microbuckling, or shear maximum applied stress) of 0.1; and failure. The mode of failure depends on the type of fiber, • A direction parallel to the principal fiber alignment. u *
  • 12. 440.2R-12 ACI COMMITTEE REPORT Test conditions that raise the temperature and moisture exposure. com These properties should be adjusted in accordance content of FRP materials generally degrade the ambient with Section 8.4 to account for the anticipated service environ-ment environment fatigue behavior. to which the FRP system may be exposed during its Of all types of FRP composites for infrastructure applications, service life. CFRP is the least prone to fatigue failure. An endurance limit of 60 to 70% of the initial static ultimate strength of CFRP is 3.6—FRP system qualification typical. On a plot of stress versus the logarithm of the number of FRP systems should be qualified for use on a project on the cycles at failure (S-N curve), the downward slope of CFRP basis of independent laboratory test data of the FRP-constituent is usually about 5% of the initial static ultimate strength per materials and the laminates made with them, structural test decade of logarithmic life. At one million cycles, the fatigue data for the type of application being considered, and durability strength is generally between 60 and 70% of the initial static data representative of the anticipated environment. Test data ultimate strength and is relatively unaffected by the moisture provided by the FRP system manufacturer demonstrating the and temperature exposures of concrete structures unless the proposed FRP system meets all mechanical and physical resin or fiber/resin interface is afzir.substantially degraded by the design requirements including tensile strength, durability, environment. resistance to creep, bond to substrate, and Tg should be In ambient-environment laboratory tests (Mandell and considered but not used as the sole basis for qualification. Meier 1983), individual glass fibers demonstrated delayed FRP composite systems that have not been fully tested rupture caused by stress corrosion, which had been induced should not be considered for use. Mechanical properties by the growth of surface flaws in the presence of even minute of FRP systems should be determined from tests on laminates quantities of moisture. When many glass fibers are embedded manufactured in a process representative of their field installa-tion. into a matrix to form an FRP composite, a cyclic tensile Mechanical properties should be tested in general fatigue effect of approximately 10% loss in the initial static conformance with the procedures listed in Appendix B. strength per decade of logarithmic lifetime is observed Modifications of standard testing procedures may be permitted (Mandell 1982). This fatigue effect is thought to be due to fiber-fiber to emulate field assemblies. interactions and not dependent on the stress corrosion The specified material-qualification programs should mechanism described for individual fibers. Usually, no require sufficient laboratory testing to measure the repeatability clear fatigue limit can be defined. Environmental factors and reliability of critical properties. Testing of multiple can play an important role in the fatigue behavior of glass batches of FRP materials is recommended. Independent fibers due to their susceptibility to moisture, alkaline, structural testing can be used to evaluate a system’s performance and acidic solutions. for the specific application. Aramid fibers, for which substantial durability data are available, appear to behave reasonably well in fatigue. PART 3—RECOMMENDED www.Neglecting in this context the rather poor durability of all CONSTRUCTION REQUIREMENTS aramid fibers in compression, the tension-tension fatigue CHAPTER 4—SHIPPING, STORAGE, AND behavior of an impregnated aramid fiber strand is excellent. HANDLING Strength degradation per decade of logarithmic lifetime is 4.1—Shipping approximately 5 to 6% (Roylance and Roylance 1981). FRP system constituent materials must be packaged and While no distinct endurance limit is known for AFRP, two-million- shipped in a manner that conforms to all applicable federal cycle endurance limits of commercial AFRP tendons and state packaging and shipping codes and regulations. for concrete applications have been reported in the range of Packaging, labeling, and shipping for thermosetting resin 54 to 73% of the ultimate tensile strength (Odagiri et al. materials are controlled by CFR 49. Many materials are 1997). Based on these findings, Odagiri suggested that the classified as corrosive, flammable, or poisonous in subchapter C maximum stress be set to 0.54 to 0.73 times the tensile (CFR 49) under “Hazardous Materials Regulations.” strength. Because the slope of the applied stress versus logarithmic endurance time of AFRP is similar to the slope 4.2—Storage of the stress versus logarithmic cyclic lifetime data, the 4.2.1 Storage conditions—To preserve the properties and individual fibers appear to fail by a strain-limited, creep-rupture maintain safety in the storage of FRP system constituent process. This lifetime-limiting mechanism in materials, the materials should be stored in accordance with commercial AFRP bars is accelerated by exposure to moisture the manufacturer’s recommendations. Certain constituent and elevated temperature (Roylance and Roylance 1981; materials, such as reactive curing agents, hardeners, initiators, Rostasy 1997). catalysts, and cleaning solvents, have safety-related require-ments and should be stored in a manner as recommended by 3.5—Durability the manufacturer and OSHA. Catalysts and initiators (usually Many FRP systems exhibit reduced mechanical properties peroxides) should be stored separately. after exposure to certain environmental factors, including 4.2.2 Shelf life—The properties of the uncured resin temperature, humidity, and chemical exposure. The exposure components can change with time, temperature, or humidity. environment, duration of the exposure, resin type and Such conditions can affect the reactivity of the mixed system formulation, fiber type, and resin-curing method are and the uncured and cured properties. The manufacturer sets some of the factors that influence the extent of the reduction in a recommended shelf life within which the properties of the mechanical properties. These factors are discussed in more resin-based materials should continue to meet or exceed detail in Section 8.3. The tensile properties reported by the stated performance criteria. Any component material that manufacturer are based on testing conducted in a laboratory has exceeded its shelf life, has deteriorated, or has been environment and do not reflect the effects of environmental contaminated should not be used. FRP materials deemed
  • 13. DESIGN AND CONSTRUCTION OF EXTERNALLY BONDED FRP SYSTEMS 440.2R-13 unusable should be disposed of in a manner specified by the Consult com the manufacturer’s literature for proper mixing manufacturer and acceptable to state and federal environmental procedures and MSDSs for specific handling hazards. Ambient control regulations. cure resin formulations produce heat when curing, which in turn accelerates the reaction. Uncontrolled reactions, including 4.3—Handling fuming, fire, or violent boiling, may occur in containers 4.3.1 Material safety data sheets—Material safety data holding a mixed mass of resin; therefore, containers should sheets (MSDS) for all FRP constituent materials and be monitored. components must be obtained from the manufacturers and 4.3.6 Clean-up and disposal—Clean-up can involve use must be accessible at the job site. of flammable solvents, and appropriate precautions 4.3.2 Information sources—Detailed information on the should be observed. Clean-up solvents are available that do handling and potential hazards of FRP constituent materials not present the same flammability concerns. All waste materials can be found in information sources, such as ACI and ICRI should be contained and disposed of as prescribed by the prevail-ing reports, company literature and guides, OSHA guidelines, environmental authority. and other government informational documents. ACI 503R is specifically noted as a general guideline for the safe handling CHAPTER 5—INSTALLATION of epoxy compounds. Procedures for installing FRP systems have been developed 4.3.3 General handling hazards—Thermosetting resins by the system manufacturers and often differ between systems. describe a generic family of products that includes unsaturated In addition, installation procedures can vary within a system, polyesters, vinyl esters, epoxy, and polyurethane resins. The depending on the type and condition of the structure. This materials used with them are generally described as hardeners, chapter presents general guidelines for the installation of FRP curing agents, peroxide initiators, isocyanates, fillers, and systems. Contractors trained in accordance with the installation flexibilizers. There are precautions that should be observed procedures developed by the system manufacturer should when handling thermosetting resins and their component install FRP systems. Deviations from the procedures developed materials. Some general hazards that may be encountered by the FRP system manufacturer should not be allowed without when handling thermosetting resins are listed as follows: consulting with the manufacturer. • Skin irritation, such as burns, afzir.rashes, and itching; • Skin sensitization, which is an allergic reaction similar 5.1—Contractor competency to that caused by poison ivy, building insulation, or The FRP system installation contractor should demonstrate other allergens; competency for surface preparation and application of the FRP • Breathing organic vapors from cleaning solvents, system to be installed. Contractor competency can be demon-strated monomers, and diluents; by providing evidence of training and documentation of • With a sufficient concentration in air, explosion or fire related work previously completed by the contractor or by actual www.of flammable materials when exposed to heat, flames, surface preparation and installation of the FRP system on pilot lights, sparks, static electricity, cigarettes, or other portions of the structure. The FRP system manufacturer or their sources of ignition; authorized agent should train the contractor’s application • Exothermic reactions of mixtures of materials causing personnel in the installation procedures of their system and fires or personal injury; and ensure they are competent to install the system. • Nuisance dust caused by grinding or handling of the cured FRP materials (consult manufacturer’s literature 5.2—Temperature, humidity, and moisture for specific hazards). considerations The complexity of thermosetting resins and associated Temperature, relative humidity, and surface moisture at materials makes it essential that labels and MSDS are read and the time of installation can affect the performance of the FRP understood by those working with these products. CFR 16, Part system. Conditions to be observed before and during installation 1500, regulates the labeling of hazardous substances and include surface temperature of the concrete, air temperature, includes thermosetting-resin materials. ANSI Z-129.1 provides relative humidity, and corresponding dew point. further guidance regarding classification and precautions. Primers, saturating resins, and adhesives generally should 4.3.4 Personnel safe handling and clothing—Disposable not be applied to cold or frozen surfaces. When the surface suits and gloves are suitable for handling fiber and resin temperature of the concrete surface falls below a minimum materials. Disposable rubber or plastic gloves are recommended level as specified by the FRP system manufacturer, improper and should be discarded after each use. Gloves should be saturation of the fibers and improper curing of the resin resistant to resins and solvents. constituent materials can occur, compromising the integrity Safety glasses or goggles should be used when handling of the FRP system. An auxiliary heat source can be used to resin components and solvents. Respiratory protection, such raise the ambient and surface temperature during installation. as dust masks or respirators, should be used when fiber fly, The heat source should be clean and not contaminate the surface dust, or organic vapors are present, or during mixing and or the uncured FRP system. placing of resins if required by the FRP system manufacturer. Resins and adhesives generally should not be applied to 4.3.5 Workplace safe handling—The workplace should be damp or wet surfaces unless they have been formulated for well ventilated. Surfaces should be covered as needed to such applications. FRP systems should not be applied to concrete protect against contamination and resin spills. Each FRP surfaces that are subject to moisture vapor transmission. The system constituent material has different handling and transmission of moisture vapor from a concrete surface storage requirements to prevent damage. Consult with the through the uncured resin materials typically appears as material manufacturer for guidance. Some resin systems are surface bubbles and can compromise the bond between the potentially dangerous during the mixing of the components. FRP system and the substrate.
  • 14. 440.2R-14 ACI COMMITTEE REPORT 5.3—Equipment adhesive com bond between the FRP system and the concrete Each FRP system has unique equipment designed specifically substrate, although one is often provided to facilitate installation. for the application of the materials for that system. This 5.4.2.1 Bond-critical applications—Surface preparation equipment can include resin impregnators, sprayers, lifting/ for bond-critical applications should be in accordance with positioning devices, and winding machines. All equipment recommendations of ACI 546R and ICRI 03730. The should be clean and in good operating condition. The concrete or repaired surfaces to which the FRP system is to contractor should have personnel trained in the operation of be applied should be freshly exposed and free of loose or all equipment. Personal protective equipment, such as unsound materials. Where fibers wrap around the corners of gloves, masks, eye guards, and coveralls, should be chosen rectangular cross sections, the corners should be rounded to and worn for each employee’s function. All supplies and a minimum 1/2 in. (13 mm) radius to prevent stress concentra-tions equipment should be available in sufficient quantities to allow in the FRP system and voids between the FRP system continuity in the installation project and quality assurance. and the concrete. Roughened corners should be smoothed with putty. Obstructions, reentrant corners, concave surfaces, 5.4—Substrate repair and afzir.surface preparation and embedded objects can affect the performance of the FRP The behavior of concrete members strengthened or retrofitted system and should be addressed. Obstructions and embedded with FRP systems is highly dependent on a sound concrete objects may need to be removed before installing the FRP substrate and proper preparation and profiling of the concrete system. Reentrant corners and concave surfaces may require surface. An improperly prepared surface can result in debonding special detailing to ensure that the bond of the FRP system to the or delamination of the FRP system before achieving the design substrate is maintained. Surface preparation can be accom-plished load transfer. The general guidelines presented in this chapter using abrasive or water-blasting techniques. All laitance, should be applicable to all externally bonded FRP systems. dust, dirt, oil, curing compound, existing coatings, and any other Specific guidelines for a particular FRP system should be matter that could interfere with the bond of the FRP system to obtained from the FRP system manufacturer. Substrate the concrete should be removed. Bug holes and other small preparation can generate noise, dust, and disruption to building surface voids should be completely exposed during surface occupants. profiling. After the profiling operations are complete, the 5.4.1 Substrate repair—All problems associated with the surface should be cleaned and protected before FRP installation condition of the original concrete and the concrete substrate so that no materials that can interfere with bond are redeposited that can compromise the integrity of the FRP system should on the surface. be addressed before surface preparation begins. ACI 546R and The concrete surface should be prepared to a minimum ICRI 03730 detail methods for the repair and surface preparation concrete surface profile (CSP) 3 as defined by the ICRI-surface- of concrete. All concrete repairs should meet the requirements profile chips. The FRP system manufacturer should of the design drawings and project specifications. The FRP be consulted to determine if more aggressive surface profiling www.system manufacturer should be consulted on the compatibility is necessary. Localized out-of-plane variations, including of the materials used for repairing the substrate with the FRP form lines, should not exceed 1/32 in. (1 mm) or the tolerances system. recommended by the FRP system manufacturer. Localized 5.4.1.1 Corrosion-related deterioration—Externally out-of-plane variations can be removed by grinding before bonded FRP systems should not be applied to concrete abrasive or water blasting or can be smoothed over using epoxy substrates suspected of containing corroded reinforcing putty if the variations are very small. Bug holes and voids steel. The expansive forces associated with the corrosion should be filled with epoxy putty. process are difficult to determine and could compromise the All surfaces to receive the strengthening system should be structural integrity of the externally applied FRP system. as dry as recommended by the FRP system manufacturer. The cause(s) of the corrosion should be addressed and the Water in the pores can inhibit resin penetration and reduce corrosion-related deterioration should be repaired before the mechanical interlocking. Moisture content should be application of any externally bonded FRP system. evaluated in accordance with the requirements of ACI 503.4. 5.4.1.2 Injection of cracks—Some FRP manufacturers 5.4.2.2 Contact-critical applications—In applications have reported that the movement of cracks 0.010 in. (0.3 mm) involving confinement of structural concrete members, and wider can affect the performance of the externally bonded surface preparation should promote continuous intimate FRP system through delamination or fiber crushing. Con-sequently, contact between the concrete surface and the FRP system. cracks wider than 0.010 in. (0.3 mm) should be Surfaces to be wrapped should, at a minimum, be flat or pressure injected with epoxy in accordance with ACI 224.1R. convex to promote proper loading of the FRP system. Large Smaller cracks exposed to aggressive environments may require voids in the surface should be patched with a repair material resin injection or sealing to prevent corrosion of existing compatible with the existing concrete. steel reinforcement. Crack-width criteria for various exposure Materials with low compressive strength and elastic modulus, conditions are given in ACI 224R. like plaster, can reduce the effectiveness of the FRP system 5.4.2 Surface preparation—Surface preparation requirements and should be removed. should be based on the intended application of the FRP system. Applications can be categorized as bond-critical or contact-critical. 5.5—Mixing of resins Bond-critical applications, such as flexural or shear Mixing of resins should be done in accordance with the FRP strengthening of beams, slabs, columns, or walls, require an system manufacturer’s recommended procedure. All resin adhesive bond between the FRP system and the concrete. components should be at a proper temperature and mixed in the Contact-critical applications, such as confinement of columns, correct ratio until there is a uniform and complete mixing of only require intimate contact between the FRP system and components. Resin components are often contrasting colors, so the concrete. Contact-critical applications do not require an full mixing is achieved when color streaks are eliminated.
  • 15. DESIGN AND CONSTRUCTION OF EXTERNALLY BONDED FRP SYSTEMS 440.2R-15 Resins should be mixed for the prescribed mixing time and Dry fibers are impregnated at the job site during the winding visually inspected for uniformity of color. The material process. manufacturer should supply recommended batch sizes, mixture Wrapping machines are primarily used for the automated ratios, mixing methods, and mixing times. wrapping of concrete columns. The tows can be wound either Mixing equipment can include small electrically powered horizontally or at a specified angle. The wrapping machine mixing blades or specialty units, or resins can be mixed by is placed around the column and automatically wraps the tow hand stirring, if needed. Resin mixing should be in quantities material around the perimeter of the column while moving sufficiently small to ensure that all mixed resin can be used up and down the column. within the resin’s pot life. Mixed resin that exceeds its pot After wrapping, prepreg systems should be cured at an life should not be used because the viscosity will continue to elevated com temperature. Usually a heat source is placed around increase and will adversely affect the resin’s ability to the column for a predetermined temperature and time schedule penetrate the surface or saturate the fiber sheet. in accordance with the manufacturer’s recommendations. Temperatures are controlled to ensure consistent quality. The 5.6—Application of constituent materials resulting FRP jackets do not have any seams or welds because Fumes can accompany the application of some FRP resins. the tows are continuous. In all of the previous application steps, FRP systems should be selected with consideration for their the FRP system manufacturer’s recommendations should be impact on the environment, including emission of volatile followed. organic compounds and toxicology. 5.6.4 Precured systems—Precured systems include shells, 5.6.1 Primer and putty—Where required, primer should strips, and open grid forms that are typically installed with an be applied to all areas on the concrete afzir.surface where the FRP adhesive. Adhesives should be uniformly applied to the system is to be placed. The primer should be placed uniformly prepared surfaces where precured systems are to be placed, on the prepared surface at the manufacturer’s specified rate except in certain instances of concrete confinement where of coverage. The applied primer should be protected from adhesion of the FRP system to the concrete substrate may not dust, moisture, and other contaminants prior to applying the be required. FRP system. Precured laminate surfaces to be bonded should be clean and prepared in accordance with the manufacturer’s recommen-dation. Putty should be used in an appropriate thickness and The precured sheets or curved shells should be placed sequence with the primer as recommended by the FRP on or into the wet adhesive in a manner recommended by the manufacturer. The system-compatible putty, which is typically FRP manufacturer. Entrapped air between layers should a thickened epoxy paste, should be used only to fill voids and be released or rolled out before the adhesive sets. Adhesive smooth surface discontinuities before the application of other should be applied at a rate recommended by the FRP materials. Rough edges or trowel lines of cured putty should manufacturer to ensure full bonding of successive layers. be ground smooth before continuing the installation. www.5.6.5 Protective coatings—Coatings should be compatible Prior to applying the saturating resin or adhesive, the primer with the FRP strengthening system and applied in accordance and putty should be allowed to cure as specified by the FRP with the manufacturer’s recommendations. Typically, the system manufacturer. If the putty and primer are fully cured, use of solvents to clean the FRP surface prior to installing additional surface preparation may be required prior to the coatings is not recommended due to the deleterious effects application of the saturating resin or adhesive. Surface solvents can have on the polymer resins. The FRP system preparation requirements should be obtained from the FRP manufacturer should approve any use of solvent-wipe system manufacturer. preparation of FRP surfaces before the application of 5.6.2 Wet layup systems—Wet layup FRP systems are protective coatings. typically installed by hand using dry fiber sheets and a The coatings should be periodically inspected and saturating resin, and the manufacturer’s recommendations maintenance should be provided to ensure the effectiveness should be followed. The saturating resin should be applied of the coatings. uniformly to all prepared surfaces where the system is to be placed. The fibers can also be impregnated in a separate process 5.7—Alignment of FRP materials using a resin-impregnating machine before placement on the The FRP-ply orientation and ply-stacking sequence should concrete surface. be specified. Small variations in angle, as little as 5 degrees, The reinforcing fibers should be gently pressed into the from the intended direction of fiber alignment can cause a uncured saturating resin in a manner recommended by the substantial reduction in strengthening. Deviations in ply FRP system manufacturer. Entrapped air between layers orientation should only be made if approved by the engineer. should be released or rolled out before the resin sets. Sufficient Sheet and fabric materials should be handled in a manner saturating resin should be applied to achieve full saturation of to maintain the fiber straightness and orientation. Fabric the fibers. kinks, folds, or other forms of severe waviness should be Successive layers of saturating resin and fiber materials reported to the engineer. should be placed before the complete cure of the previous layer of resin. If previous layers are cured, interlayer surface 5.8—Multiple plies and lap splices preparation, such as light sanding or solvent application as Multiple plies can be used, provided all plies are fully recommended by the system manufacturer, may be required. impregnated with the resin system, the resin shear strength is 5.6.3 Machine-applied systems—Machine-applied systems sufficient to transfer the shearing load between plies, and the can use resin-preimpregnated tow or dry-fiber tows. Prepreg bond strength between the concrete and FRP system is tows are impregnated with saturating resin off-site and sufficient. For long spans, multiple lengths of fiber material delivered to the work site as spools of prepreg tow material. or precured stock can be used to continuously transfer the