This document discusses corrosion under insulation (CUI) at BP Sharjah's liquid petroleum gas plant and efforts to reduce the risk of CUI through non-intrusive inspection. It outlines that CUI poses a major threat due to the plant's coastal location and insulation that is over 25 years old. BP Sharjah implemented a risk-based program including criticality surveys, visual inspections of critical areas, radiography of high-risk locations, and repair/rehabilitation. Profile radiography found corrosion indications in 30% of areas in 2007 and 15% in 2008, and allowed repair of 10% and 3.5% of areas respectively. The conclusion is that CUI detection is challenging and prevention through design and avoidance of