Ex ic
Intrinsic Safety’s
New Protection Level
Intrinsic Safety Solutions
January 2015
WP EX ic
DRAFT - 08 January 2015
Synopsis
The protection of electrical apparatus for use in flammable atmospheres is embracing a new
technique: Ex ic. As a logical extension of the existing intrinsic safety concept, it formalises
the application of intrinsic safety in Zone 2 hazardous areas, but users and manufacturers alike
are wrestling with the details. The discussion centres as much on the withdrawal of the Ex nL
technique, as on the application of Ex ic which replaces it. The paper deals primarily with the
impact on countries that follow IEC and ATEX practice, but there are parallels with the ‘non-
incendive’ technique that is adopted in North America.
What is Ex ic ?
Ex ic is a form of intrinsic safety protection
for electrical apparatus in flammable
atmospheres. It is a logical extension of the
long-established Ex ia and Ex ib protection
levels, and is suitable for use in, or connection
into, Zone 2 hazardous areas where there is
a low probability of a flammable risk. Ex ic
retains the unique characteristic of all intrinsic
safety systems in which the wiring and
field apparatus may be ‘live-worked’ in the
presence of a flammable atmosphere.
The safety factors and equipment construction
requirements are however more relaxed than
for the Ex ia and ib protection levels, to take
account of the lower risks associated with
Zone 2. In common with the other protection
levels, Ex ic is best suited to instrumentation
circuits, where the levels of voltage and
current are consistent with those permitted
by intrinsic safety, although Ex ic can take
advantage of the Zone 2 relaxations to drive
somewhat larger loads.
Zone 0 In which an explosive gas-air
mixture is continuously pres-
ent or present for long periods
Zone 1 In which an explosive gas-air
mixture is likely to occur in
normal operation
Zone 2 In which an explosive gas-air
mixture is not likely occur in
normal operation, and if it
occurs it will exist only for a
short time
Level of protection Zone of use Fault Count
Ex ia Zone 0 Safe with 2 countable
faults
Ex ib Zone 1 Safe with 1 countable
fault
Ex ic Zone 2 Safe with no countable
faults
(ie safe in normal
operation)
The position of Ex ic in the Intrinsic Safety FamilyThe IEC Area Classification System
2 WP EX IC
DRAFT - 08 January 2015
The concept of a third level of protection
for intrinsic safety has existed for several
decades, but only recently has it been
formally adopted into the major standards
systems in common use worldwide.
Meanwhile, other methods of protection
had filled the gap. In particular, Ex nL, a
subset of the ‘safe in normal operation’
standard, Ex n, had provided a workable
but somewhat loosely defined alternative.
Ex nL (where the L referred to its energy-
limited provenance), borrowed heavily
from the published intrinsic safety ignition
data to provide a method of protection in
which instrumentation circuits could be
live-worked in Zone 2. In North America,
the ‘nonincendive’ method also delivers
a roughly equivalent approach as part
of its wide portfolio: the ‘nonincendive
with field wiring parameters’ technique
allows limited live-working in Division 2
hazardous areas.
Method of
Protection
Ex code Permitted in:
Zone 0 Zone 1 Zone 2
Encapsulation
ma 3 3 3
mb 3 3
Oil immersion o 3 3
Powder filling q 3 3
Pressurisation p 3 3
Flameproof
da 3 3 3
db 3 3
dc 3
Intrinsic
safety
ia 3 3 3
ib 3 3
ic 3
Increased safety e 3 3
Type of
protection
“n”
nA 3
nR 3
nC 3
The IEC methods of protection and permitted Zone of use
So why have things changed at last? One major factor is that Ex nL had for a long
time been an uncomfortable bed-fellow with the other protection concepts that were
part of the overall Ex n concept. Whereas Ex nL conformed to the relatively low
voltage and current levels of energy-limitation, there were no such restrictions for the
Ex nA (non-arcing), Ex nC (containment) and Ex nR (restricted breathing) techniques,
which were therefore appropriate for heavy-current switchgear and rotating machines.
Ex nL was more concerned with milliwatts than with kilowatts. The relevant expertise
on low power circuits already existed within the IEC’s intrinsic safety committee, so
as long ago as 2003, the IEC main technical committee TC31 decided to discontinue
the Ex nL technique. Another influence has been the introduction of IEC ‘Equipment
Protection Levels’, which formalise the application of the Ex methods to the different
hazardous area Zones using the a, b and c suffices for Zones 0, 1 and 2 respectively.
Ex ic
Intrinsic Safety’s
New Protection Level
3WP Ex ic
DRAFT - 08 January 2015
These also tie in with the ATEX ‘Categories’ 1, 2 and 3.
So, in recognition that Ex nL already owed much of its provenance to intrinsic safety,
the Ex nL technique was divested from Ex n and reinstated as Ex ic. Consequently,
Ex ic was introduced into the 2006 version of the intrinsic safety standard, IEC 60079-
11 Edition 5.0 (and re-confirmed in the 2011 version, Edition 6.0), and the Ex nL sub-
category was removed from the 2010 version of the IEC 60079-15 apparatus standard
for Ex n. Other relevant intrinsic safety standards, such as the systems standard (IEC
60079-25) have also been updated to take account of Ex ic.
These decisions have affected equipment manufacturers and end-users alike. From
April 2013, manufacturers were no longer permitted to put ATEX-certified Ex nL
apparatus onto the market. Existing Ex nL installations can remain in service, but any
new projects that would previously have adopted Ex nL must now be protected by an
alternative means - including Ex ic if suitably certified apparatus is available.
Zone ATEX Category IEC Protection Level
Zone 0 1 a
Zone 1 2 b
Zone 2 3 c
ATEX Categories and IEC Protection Levels according to Hazardous Area Zone
The same, but different
Ex nL and Ex ic share many underpinning
principles for the explosion protection of
low-power electrical apparatus. They are
both based on the concept of energy-
limitation, by which the levels of voltage
and current present in the field wiring are
incapable of causing ignition even if the
circuits are shorted or broken. They both
apply a unity ‘factor of safety’ Note 1
to the
current level, and both are restricted to
use in Zone 2. The migration to the parent
technique of intrinsic safety has however
created a number of detailed differences
as a result of applying the broader intrinsic
safety requirements (ie those created for
ia and ib circuits) to Ex ic.
One notable difference relates to the
required separation distance between
the terminals of intrinsically safe and non-
intrinsically safe apparatus, for example
where electronic modules and field-wiring
terminals are installed onto DIN-rail in
equipment cabinets. Ex nL was classified
as a non-IS technique and hence its
terminals required minimal separation
from those of other non-IS circuits, but
they were required to be separated by
50mm from IS circuits. However, Ex ic
terminals are IS, so the converse is true:
they must have the 50mm separation
from non-IS circuits, but not from other (ie
Ex ia or ib) IS circuits.
Ex nL Ex ic
Ex nL 1.3mm Note 2 50mm
Other non-IS circuits 1.3mm Note 2 50mm
All IS circuits (including ia, ib and ic) 50mm 6mm
Required separation distances between terminals of Ex ic, Ex nL and other apparatus
4 WP EX IC
DRAFT - 08 January 2015
Other differences include:
	 •	 The combinations of protection types that can occupy the same
		 multi-core cable (Ex ic can share the same multi-core as other IS
		 circuits, but nL cannot);
	 •	 The constructional requirements of transformers;
	 •	 The values of ‘creepage and clearance’ between tracks on printed
		circuit boards.
Such changes mean that apparatus that was previously certified Ex nL may not
automatically be re-certifiable as Ex ic, for example if the physical positioning of the
electrical connections fall foul of the connector separation requirement.
Win some, lose some
Some practitioners will see the imposition of intrinsic safety’s broader requirements
as a negative step, and will bemoan the loss of flexibility that accompanied Ex nL.
But bringing Ex ic into the intrinsic safety fold can be argued to have a number of
significant advantages:
	 •	 Installation and maintenance requirements are now defined by Intrinsic
		 Safety’s clear, internationally recognized standards and codes of practice;
	 •	 More power is available for IS circuits, as a result of the unity factor of
		 safety on current and a single active current limit;
	 •	 Intrinsic Safety is consolidated as a protection method for all hazardous
		area Zones;
	 •	 Combinations of Ex ia, ib and ic apparatus are permitted in the same
		 system, subject to the Zone of use.
	 •	 The Temperature Classification (T Class) for Ex ic is easy to define,
		 because the apparatus is assumed to be in ‘normal operation’.
A case study:
Ex ic in Fieldbus Networks
A common application of Ex nL
has been in the design and use of
FOUNDATIONTM
fieldbus networks
for instrumentation in the process
industries. Typically, the ‘spur’
connections of field device couplers
(sometimes referred to as wiring hubs)
were certified as Ex nL associated
apparatus, to allow the spur wiring
to be live-worked when connected to
suitably certified field instruments in a
Zone 2 hazardous area.
Historically the field instruments
connected to the spurs were
certified either as Ex nL apparatus,
or as Ex ia or ib on the basis that
the intrinsic safety construction
requirements exceed those of Ex nL.
This approach delivered a flexible,
low cost installation, where the field
instruments could be easily replaced
without needing to power down the
network or to declare that the area as
gas-free.
The idea of Ex ic is logical and relatively easy to grasp: a new level of intrinsic
safety that is safe in normal operation, but where open and short-circuits in
the field wiring are included in the definition of “normal”. This means that the
wiring can be live-worked.
Ex ic
Intrinsic Safety’s
New Protection Level
5WP Ex ic
DRAFT - 08 January 2015
The safety of the Ex nL spurs was achieved using energy-limitation, by capping the
voltage and current entering the spur circuit: the spur voltage was defined by the
maximum output of the network power supply, and current limitation was provided
by the individual spur short-circuit protection circuits in the device couplers. Tests
performed during the certification process would have confirmed that opening or
shorting the spur connections was incapable of igniting the most easily ignitable gas-
air mixture, as defined by the intended Gas Group. Stored energy in the spur cables
was also considered by defining appropriate cable parameters.
Zone 2 Hazardous Area
Ex nA [nL]
apparatus
Fieldbus spur Ex nL
Ex nL or Ex i certified
Fieldbus instruments
Ex nA trunk, with
voltage limitation in
accordance wth Ex nL
Current limitation in
accordance with
Ex nL
Fieldbus
Control
system I/O
card
Fieldbus Power
supply with
voltage
limitation
Device
Coupler
With Ex nL, the fieldbus application used the power supply’s inherent voltage limitation
With the migration to Ex ic, the essential voltage and current limitation still apply,
except that they now have to comply with the Ex ic requirements of IEC 60079-11. At
face value, the transition would appear to be relatively trivial, but the detail changes
have a subtle, and in some cases radical effect on the hardware design.
A particular area of interest is the fieldbus trunk (the cable that carries power from
the control-room mounted power supply to the field-mounted device coupler). Under
the Ex nL spur regime, the trunk wiring could be declared as Ex nA (ie non-sparking,
meaning that it is designed and installed such that sparking cannot take place), but
with voltage limitation in accordance with Ex nL.
6 WP EX IC
DRAFT - 08 January 2015
This raised few eyebrows because there was no essential incompatibility between
the two Ex n techniques in this application. However, the question arises whether
the trunk cable can be declared as Ex nA but with intrinsically safe (ie Ex ic) voltage
limitation. Is the trunk now an intrinsically safe circuit or not? Can it be half intrinsically
safe, and if so how would it be treated in terms of installation and separation from
other circuits?
Zone 2 Hazardous Area
Ex nA [ic]
apparatus
Fieldbus spur Ex ic
Ex i certified
Fieldbus instruments
Ex nA trunk
Current limitation in
accordance with
Ex ic
Fieldbus
Control
system I/O
card
Fieldbus Power
supply
Device
Coupler
Ex ic
voltage
limitation
With Ex ic, a separate voltage limiter is inserted to avoid an ambiguous Ex nA/ic classification for the fieldbus trunk
This particular point demonstrates how the looser interpretation of Ex nL permitted
a real-life application, whereas Ex ic requires a more rigorous approach. As a
manufacturer of field wiring components for Foundation fieldbus networks, the
author’s company has considered carefully how to develop a safe and workable
network with Ex ic spurs. The primary design requirements were:
	 •	 To attempt to comply with the safest interpretation of Ex ic requirements,
		 in particular where the certification organisations (notified bodies) held
		differing views;
	 •	 To unambiguously identify the Ex method of protection invoked for
		 each part of the network, so that the user can install and maintain
		it appropriately.
Ex ic
Intrinsic Safety’s
New Protection Level
7WP Ex ic
DRAFT - 08 January 2015
The resulting solution, and its comparison with the preceding Ex nL implementation,
provides a useful window on how the migration to Ex ic may affect other areas of
instrumentation. One particular characteristic of the fieldbus application is to move
the circuitry that performs the Ex ic voltage limitation from the network power
supply to a separate unit located in the field, close to the device coupler. This has
the benefit of rendering the trunk entirely Ex nA in certification terms, meaning that
it does not attract any requirement to separate it from other non-intrinsically safe
circuits. Importantly, this avoids the need to treat the trunk wiring (and its associated
terminals) as intrinsically safe where it weaves its path through the control room
marshalling cabinet. Alternative solutions with the Ex ic voltage limitation in the power
supply have to provide the necessary 50mm separation between the trunk terminals
and those of other non-IS circuits - assuming the installer has read the details in the
vendor’s instruction manual!
A further benefit of classifying the trunk as Ex nA (and only nA), is that other non-
intrinsically safe field devices can be connected to the trunk via a conventional device
coupler, allowing a mix of Ex nA, Ex d and Ex i instruments on the same segment.
This arrangement is questionable if the trunk is classified as part Ex nA, part Ex ic.
Whether it was permissible under Ex nL rules is also difficult to say for certain, since
the relevant installation requirements were poorly defined.
Zone 2 Hazardous Area
Ex nA [ic]
apparatus
Fieldbus spur Ex ic
Ex i certified
Fieldbus instruments
Fieldbus
Control
system I/O
card
Fieldbus Power
supply
Device
Coupler
Ex ic
voltage
limitation
Ex d or Ex nA certified
Fieldbus instrument
A benefit of defining the trunk as Ex nA is that Ex d or Ex nA field devices can also be connected to the segment
8 WP EX IC
DRAFT - 08 January 2015
Managing the transition
As the instrumentation community adapts to the brave new world of Ex ic, other
questions come to mind. Can apparatus certified as Ex nL be used in Ex ic circuits,
and vice-versa? Such questions are most likely to be relevant to existing ‘nL’
installations, or to the re-use of ‘nL’ certified field instruments. New installations
will be driven entirely to ‘ic’ because of the unavailability of ‘nL’ certified apparatus.
However, the use of ‘nL’ apparatus in ‘ic’ systems does already have a precedent,
since it is covered in the FISCO (Fieldbus Intrinsically Safe Concept) annex of the
system standard IEC 60079-25. This can be extended to other fieldbus systems, and
arguably also to other non-fieldbus Ex ic circuits. If the ‘nL’ apparatus parameters
are well defined, it can be used. The analysis should be recorded in the system
documentation. In practice, this is most likely to apply to the use of an Ex nL certified
field transmitter in an Ex ic circuit.
Where the safety parameters of an ‘ic’ apparatus are compatible with the
requirements of the system (they may be more detailed than those of the ‘nL’
apparatus), then the ‘ic’ apparatus can be used in an ‘nL’ system. Again, the change
should be justified and recorded in the system documentation. This would cover the
use of an ‘ic’ field transmitter in an existing ‘nL’ installation.
The details of such issues are still under discussion in hazardous area forums. For
example, voices within the IEC ‘maintenance team’ for the intrinsic safety standard
are arguing that the new situation is just too complicated. Their point is that the rules
for Ex ic should have been much more akin to those for Ex nL: in effect, a re-naming
of the technique but not a complete re-definition. Could there yet be a ‘U-turn’?
Possibly, but only in the lengthy timescales needed to up-issue an Ex standard.
Just to keep everyone on their toes, another important change is pending in the
certification world: Ex nA will itself be withdrawn from the IEC 60079-15 standard,
and replaced by a new “Ex ec” level of protection in IEC 60079-7 for ‘increased
safety’ apparatus. In common with Ex ic, the use of Level of Protection ‘c’ is invoked
for Zone 2, but this time it is being applied to normally non-sparking apparatus and
circuits. Again, although the inherent characteristics of nA will transfer to a new level
in the increased safety standard, there will be detail differences that mean existing nA
apparatus may not be automatically re-certifiable as Ex ec. It is probable that the new
edition of the IEC 60079-7 standard containing Ex ec will appear at the end of 2015,
and become an ATEX harmonised standard possibly mid-2016.
Ex ic
Intrinsic Safety’s
New Protection Level
9WP Ex ic
DRAFT - 08 January 2015
In summary
The idea of Ex ic is logical and relatively easy to grasp: a new level of intrinsic safety
that is safe in normal operation, but where open- and short-circuits in the field wiring
are included in the definition of “normal”. This means that the wiring can be live-
worked. It is restricted to Zone 2, in which any flammable atmosphere is fleeting.
Its IEC predecessor, Ex nL, embraced the same concept but was adopted with more
flexibility because, unlike intrinsic safety, the overall installation requirements were
less well defined. The withdrawal of Ex nL will therefore leave a gap that Ex ic may
find difficult to fill, especially where manufacturers find that existing Ex nL products
cannot be automatically re-certified as Ex ic. It may take some time for the dust to
settle.
The formalisation of the design, installation and maintenance rules that follow
from the absorption of Ex ic into the broader world of intrinsic safety are however
to be welcomed. It would difficult to point to ways in which Ex nL was less safe,
but it was less well understood (and therefore more vulnerable to widely different
interpretations) than intrinsic safety.
The situation is further complicated by the fact that the standards organisations are
still debating whether the technical requirements of Ex ic are too onerous - even after
the new standard has been published. So it is yet possible that future versions of the
intrinsic safety standard will relax the rules and move the goalposts again!
10 WP EX IC
DRAFT - 08 January 2015
Notes
	 1.	 The ‘factor of safety’ refers to a safety margin that is applied to the permitted
		 current level. For a given voltage level, the published ‘ignition curves’ define the
		 maximum current at which ignition does not occur. With intrinsic safety
		 protection levels Ex ia and ib, the actual current is reduced by 50%; with Ex ic,
		 no margin is applied.
	 2.	 The separation distance depends on the voltage. For Ex nL circuits defined as
		 ‘low power’ it is zero. For up to 32V, the required separation is 1.3mm.
Ex ic
Intrinsic Safety’s
New Protection Level
11WP Ex ic
DRAFT - 08 January 2015
DRAFT - 08 January 2015
EUROPE (EMEA):
+44 (0)1582 723633
mtlenquiry@eaton.com
THE AMERICAS:
+1 800 835 7075	
mtl-us-info@eaton.com
ASIA-PACIFIC:
+65 6 645 9888
sales.mtlsing@eaton.com
The given data is only intended as a product
description and should not be regarded as a legal
warranty of properties or guarantee. In the interest
of further technical developments, we reserve the
right to make design changes.
Measurement Technology Limited,
Great Marlings, Butterfield, Luton
Beds, LU2 8DL, UK.
Tel: + 44 (0)1582 723633 Fax: + 44 (0)1582 422283
E-mail: mtlenquiry@eaton.com
www.mtl-inst.com
© 2014 MTL
All Rights Reserved
Publication No. WP Ex ic
January 2015
AUSTRALIA
MTL Instruments Pty Ltd,
205-209 Woodpark Road, Smithfield,
New South Wales 2164, Australia
Tel: + 61 1300 308 374 Fax: + 61 1300 308 463
E-mail: mtlsalesanz@eaton.com
BeNeLux
MTL Instruments BV
Terheijdenseweg 465, 4825 BK Breda
The Netherlands
Tel: + 31 (0) 76 7505360 Fax: +31 (0) 76 7505370
E-mail: mtl.benelux@eaton.com
CHINA
Cooper Electric (Shanghai) Co. Ltd
955 Shengli Road, Heqing Industrial Park
Pudong New Area, Shanghai 201201
Tel: + 86 2128993817 Fax: + 86 2128993992
E-mail: mtl-cn@eaton.com
FRANCE
MTL Instruments sarl,
7 rue des Rosiéristes, 69410 Champagne au Mont d’Or
France
Tel: + 33 (0)4 37 46 16 70 Fax: +33 (0)4 37 46 17 20
E-mail: mtlfrance@eaton.com
GERMANY
MTL Instruments GmbH,
Heinrich-Hertz-Str. 12, 50170 Kerpen, Germany
Tel: + 49 (0)22 73 98 12 - 0 Fax: + 49 (0)22 73 98 12 - 2 00
E-mail: mtlgmbh@eaton.com
INDIA
MTL India,
No.36, Nehru Street, Off Old Mahabalipuram Road
Sholinganallur, Chennai - 600 119, India
Tel: + 91 (0) 44 24501660 /24501857 Fax: + 91 (0) 44 24501463
E-mail: mtlindiasales@eaton.com
ITALY
MTL Italia srl,
Via A. Meucci, 10, I-20094 Corsico (MI), Italy
Tel: + 39 (0)2 61802011 Fax: + 39 (0)2 61294560
E-mail: chmninfo@eaton.com
JAPAN
Cooper Crouse-Hinds Japan KK,
MT Building 3F, 2-7-5 Shiba Daimon, Minato-ku,
Tokyo, Japan 105-0012
Tel: + 81 (0)3 6430 3128 Fax: + 81 (0)3 6430 3129
E-mail: mtl-jp@eaton.com
NORWAY
Norex AS
Fekjan 7c, Postboks 147,
N-1378 Nesbru, Norway
Tel: + 47 66 77 43 80 Fax: + 47 66 84 55 33
E-mail: info@norex.no
SINGAPORE
Cooper Crouse-Hinds Pte Ltd
No 2 Serangoon North Avenue 5, #06-01 Fu Yu Building
Singapore 554911
Tel: + 65 6 645 9888 Fax: + 65 6 487 7997
E-mail: sales.mtlsing@eaton.com
SOUTH KOREA
Cooper Crouse-Hinds Korea
12F, Vision Tower, 707-2 Yeoksam-Dong Gangnam-Gu,
Seoul 135-080, South Korea.
Tel: + 82 2 538 3481 Fax: + 82 2 538 3505
E-mail: mtl-korea@eaton.com
UNITED ARAB EMIRATES
Cooper Industries/Eaton Corporation
Office 205/206, 2nd Floor SJ Towers, off. Old Airport Road,
Abu Dhabi, United Arab Emirates
Tel: + 971 2 44 66 840 Fax: + 971 2 44 66 841
E-mail: mtlgulf@eaton.com
UNITED KINGDOM
Measurement Technology Limited,
Great Marlings, Butterfield, Luton
Beds LU2 8DL
Tel: + 44 (0)1582 723633 Fax: + 44 (0)1582 422283
E-mail: mtlenquiry@eaton.com
AMERICAS
Cooper Crouse-Hinds MTL Inc.
3413 N. Sam Houston Parkway W.
Suite 210, Houston TX 77086, USA
Tel: + 1 281-571-8065 Fax: + 1 281-571-8069
E-mail: mtl-us-info@eaton.com

More Related Content

What's hot

17th Edition Part 4
17th  Edition  Part 417th  Edition  Part 4
17th Edition Part 4Paul Holden
 
Early warning surge&lightning (electrical safety ) for valuable equipment...
Early warning surge&lightning (electrical safety ) for valuable equipment...Early warning surge&lightning (electrical safety ) for valuable equipment...
Early warning surge&lightning (electrical safety ) for valuable equipment...Mahesh Chandra Manav
 
Nbc2016 and iec information jmv lps
Nbc2016 and iec information jmv lpsNbc2016 and iec information jmv lps
Nbc2016 and iec information jmv lpsMahesh Chandra Manav
 
17th Edition Part 2 3
17th Edition  Part 2   317th Edition  Part 2   3
17th Edition Part 2 3Paul Holden
 
Electrical equipment instalation safety of products and human by jmv lps
Electrical equipment instalation safety of products and human by jmv lpsElectrical equipment instalation safety of products and human by jmv lps
Electrical equipment instalation safety of products and human by jmv lpsMahesh Chandra Manav
 
Lightning protection of windmill
Lightning protection of windmill Lightning protection of windmill
Lightning protection of windmill AKHIL G
 
On-Chip ESD Protection with Improved High Holding Current SCR (HHISCR) Achiev...
On-Chip ESD Protection with Improved High Holding Current SCR (HHISCR) Achiev...On-Chip ESD Protection with Improved High Holding Current SCR (HHISCR) Achiev...
On-Chip ESD Protection with Improved High Holding Current SCR (HHISCR) Achiev...Sofics
 
Overvoltage protection of data concentrators used in smart
Overvoltage protection of data concentrators used in smartOvervoltage protection of data concentrators used in smart
Overvoltage protection of data concentrators used in smartRaja Sekhar
 
17th Edition Part 5 1
17th  Edition  Part 5 117th  Edition  Part 5 1
17th Edition Part 5 1Paul Holden
 
Surge Protection Device
Surge Protection DeviceSurge Protection Device
Surge Protection DeviceJmv Lps
 
Ditek FPK2 Data Sheet
Ditek FPK2 Data SheetDitek FPK2 Data Sheet
Ditek FPK2 Data SheetJMAC Supply
 
Why Test Series - Arc Flash Evaluations CS-00158
Why Test Series - Arc Flash Evaluations CS-00158Why Test Series - Arc Flash Evaluations CS-00158
Why Test Series - Arc Flash Evaluations CS-00158Carolyn Dakis
 
Presentation lightning protection system by jmv lps
Presentation lightning protection system by jmv lpsPresentation lightning protection system by jmv lps
Presentation lightning protection system by jmv lpsMahesh Chandra Manav
 
Circuit protection devices perfect ppt
Circuit protection devices perfect ppt Circuit protection devices perfect ppt
Circuit protection devices perfect ppt vikram rajpurohit
 
IRJET- Embedded System based Multi-Source Leakage Current Protection for Low ...
IRJET- Embedded System based Multi-Source Leakage Current Protection for Low ...IRJET- Embedded System based Multi-Source Leakage Current Protection for Low ...
IRJET- Embedded System based Multi-Source Leakage Current Protection for Low ...IRJET Journal
 
17th Edition Part 6
17th Edition  Part 617th Edition  Part 6
17th Edition Part 6Paul Holden
 

What's hot (20)

17th Edition Part 4
17th  Edition  Part 417th  Edition  Part 4
17th Edition Part 4
 
Early warning surge&lightning (electrical safety ) for valuable equipment...
Early warning surge&lightning (electrical safety ) for valuable equipment...Early warning surge&lightning (electrical safety ) for valuable equipment...
Early warning surge&lightning (electrical safety ) for valuable equipment...
 
Nbc2016 and iec information jmv lps
Nbc2016 and iec information jmv lpsNbc2016 and iec information jmv lps
Nbc2016 and iec information jmv lps
 
17th Edition Part 2 3
17th Edition  Part 2   317th Edition  Part 2   3
17th Edition Part 2 3
 
Electrical equipment instalation safety of products and human by jmv lps
Electrical equipment instalation safety of products and human by jmv lpsElectrical equipment instalation safety of products and human by jmv lps
Electrical equipment instalation safety of products and human by jmv lps
 
The Elektro Tipp - Array Junction Boxes
The Elektro Tipp - Array Junction BoxesThe Elektro Tipp - Array Junction Boxes
The Elektro Tipp - Array Junction Boxes
 
Lightning protection of windmill
Lightning protection of windmill Lightning protection of windmill
Lightning protection of windmill
 
On-Chip ESD Protection with Improved High Holding Current SCR (HHISCR) Achiev...
On-Chip ESD Protection with Improved High Holding Current SCR (HHISCR) Achiev...On-Chip ESD Protection with Improved High Holding Current SCR (HHISCR) Achiev...
On-Chip ESD Protection with Improved High Holding Current SCR (HHISCR) Achiev...
 
Overvoltage protection of data concentrators used in smart
Overvoltage protection of data concentrators used in smartOvervoltage protection of data concentrators used in smart
Overvoltage protection of data concentrators used in smart
 
Intrinsic safety
Intrinsic safetyIntrinsic safety
Intrinsic safety
 
17th Edition Part 5 1
17th  Edition  Part 5 117th  Edition  Part 5 1
17th Edition Part 5 1
 
Surge Protection Device
Surge Protection DeviceSurge Protection Device
Surge Protection Device
 
Surge Protective Device -Meba
Surge Protective Device -MebaSurge Protective Device -Meba
Surge Protective Device -Meba
 
Ditek FPK2 Data Sheet
Ditek FPK2 Data SheetDitek FPK2 Data Sheet
Ditek FPK2 Data Sheet
 
Why Test Series - Arc Flash Evaluations CS-00158
Why Test Series - Arc Flash Evaluations CS-00158Why Test Series - Arc Flash Evaluations CS-00158
Why Test Series - Arc Flash Evaluations CS-00158
 
Presentation lightning protection system by jmv lps
Presentation lightning protection system by jmv lpsPresentation lightning protection system by jmv lps
Presentation lightning protection system by jmv lps
 
Circuit protection devices perfect ppt
Circuit protection devices perfect ppt Circuit protection devices perfect ppt
Circuit protection devices perfect ppt
 
Surge supressor
Surge supressorSurge supressor
Surge supressor
 
IRJET- Embedded System based Multi-Source Leakage Current Protection for Low ...
IRJET- Embedded System based Multi-Source Leakage Current Protection for Low ...IRJET- Embedded System based Multi-Source Leakage Current Protection for Low ...
IRJET- Embedded System based Multi-Source Leakage Current Protection for Low ...
 
17th Edition Part 6
17th Edition  Part 617th Edition  Part 6
17th Edition Part 6
 

Viewers also liked

DEVELOPMENT OF NEUROFUZZY CONTROL SYSTEM FOR THE GUIDANCE OF AIR TO AIR MISS...
DEVELOPMENT OF NEUROFUZZY CONTROL SYSTEM FOR THE GUIDANCE OF AIR TO AIR  MISS...DEVELOPMENT OF NEUROFUZZY CONTROL SYSTEM FOR THE GUIDANCE OF AIR TO AIR  MISS...
DEVELOPMENT OF NEUROFUZZY CONTROL SYSTEM FOR THE GUIDANCE OF AIR TO AIR MISS...Ahmed Momtaz Hosny, PhD
 
Naval Aircraft & Missiles Web
Naval Aircraft & Missiles WebNaval Aircraft & Missiles Web
Naval Aircraft & Missiles WebLynn Seckinger
 
Tactical Missile Design
Tactical Missile DesignTactical Missile Design
Tactical Missile DesignJim Jenkins
 
BHEL HARIDWAR,CONSTRUCTION OF TURBO GENERATOR AND EXCITATION SYSTEM
BHEL HARIDWAR,CONSTRUCTION OF TURBO GENERATOR AND EXCITATION SYSTEMBHEL HARIDWAR,CONSTRUCTION OF TURBO GENERATOR AND EXCITATION SYSTEM
BHEL HARIDWAR,CONSTRUCTION OF TURBO GENERATOR AND EXCITATION SYSTEMyash Natani
 
Brushless DC Excitation Systems
Brushless DC Excitation SystemsBrushless DC Excitation Systems
Brushless DC Excitation SystemsSharmili Palli
 
Intrinsic safety and flameproof apparatus in mines
Intrinsic safety and flameproof apparatus in minesIntrinsic safety and flameproof apparatus in mines
Intrinsic safety and flameproof apparatus in minesJayachandra Jitendra
 
Turbine compressor introduction
Turbine compressor introductionTurbine compressor introduction
Turbine compressor introductionFurqan Pakot
 
Excitation System & capability curve of synchronous generator
Excitation System &  capability curve of synchronous generatorExcitation System &  capability curve of synchronous generator
Excitation System & capability curve of synchronous generatorMANOJ KUMAR MAHARANA
 
Startup Metrics, a love story. All slides of an 6h Lean Analytics workshop.
Startup Metrics, a love story. All slides of an 6h Lean Analytics workshop.Startup Metrics, a love story. All slides of an 6h Lean Analytics workshop.
Startup Metrics, a love story. All slides of an 6h Lean Analytics workshop.Andreas Klinger
 
Ppt turbo generator
Ppt turbo generatorPpt turbo generator
Ppt turbo generatorsunil kumar
 
Northcom basic briefing
Northcom basic briefingNorthcom basic briefing
Northcom basic briefingICSA, LLC
 
PPT ON GUIDED MISSILES
PPT ON GUIDED MISSILESPPT ON GUIDED MISSILES
PPT ON GUIDED MISSILESSneha Jha
 

Viewers also liked (20)

Exloc is hj
Exloc is hjExloc is hj
Exloc is hj
 
DEVELOPMENT OF NEUROFUZZY CONTROL SYSTEM FOR THE GUIDANCE OF AIR TO AIR MISS...
DEVELOPMENT OF NEUROFUZZY CONTROL SYSTEM FOR THE GUIDANCE OF AIR TO AIR  MISS...DEVELOPMENT OF NEUROFUZZY CONTROL SYSTEM FOR THE GUIDANCE OF AIR TO AIR  MISS...
DEVELOPMENT OF NEUROFUZZY CONTROL SYSTEM FOR THE GUIDANCE OF AIR TO AIR MISS...
 
Naval Aircraft & Missiles Web
Naval Aircraft & Missiles WebNaval Aircraft & Missiles Web
Naval Aircraft & Missiles Web
 
Tactical Missile Design
Tactical Missile DesignTactical Missile Design
Tactical Missile Design
 
BHEL HARIDWAR,CONSTRUCTION OF TURBO GENERATOR AND EXCITATION SYSTEM
BHEL HARIDWAR,CONSTRUCTION OF TURBO GENERATOR AND EXCITATION SYSTEMBHEL HARIDWAR,CONSTRUCTION OF TURBO GENERATOR AND EXCITATION SYSTEM
BHEL HARIDWAR,CONSTRUCTION OF TURBO GENERATOR AND EXCITATION SYSTEM
 
Brushless DC Excitation Systems
Brushless DC Excitation SystemsBrushless DC Excitation Systems
Brushless DC Excitation Systems
 
Intrinsic Safety Explained
Intrinsic Safety ExplainedIntrinsic Safety Explained
Intrinsic Safety Explained
 
Intrinsic safety and flameproof apparatus in mines
Intrinsic safety and flameproof apparatus in minesIntrinsic safety and flameproof apparatus in mines
Intrinsic safety and flameproof apparatus in mines
 
Combustion gas turbines
Combustion gas turbinesCombustion gas turbines
Combustion gas turbines
 
Turbine compressor introduction
Turbine compressor introductionTurbine compressor introduction
Turbine compressor introduction
 
Excitation System & capability curve of synchronous generator
Excitation System &  capability curve of synchronous generatorExcitation System &  capability curve of synchronous generator
Excitation System & capability curve of synchronous generator
 
Turbo-Generator
Turbo-GeneratorTurbo-Generator
Turbo-Generator
 
NFI - Industrial Pneumatics
NFI - Industrial PneumaticsNFI - Industrial Pneumatics
NFI - Industrial Pneumatics
 
Startup Metrics, a love story. All slides of an 6h Lean Analytics workshop.
Startup Metrics, a love story. All slides of an 6h Lean Analytics workshop.Startup Metrics, a love story. All slides of an 6h Lean Analytics workshop.
Startup Metrics, a love story. All slides of an 6h Lean Analytics workshop.
 
Ppt turbo generator
Ppt turbo generatorPpt turbo generator
Ppt turbo generator
 
Northcom basic briefing
Northcom basic briefingNorthcom basic briefing
Northcom basic briefing
 
PPT ON GUIDED MISSILES
PPT ON GUIDED MISSILESPPT ON GUIDED MISSILES
PPT ON GUIDED MISSILES
 
Gas turbine course
Gas turbine courseGas turbine course
Gas turbine course
 
Missles flight control systems
Missles flight control systemsMissles flight control systems
Missles flight control systems
 
Surge in compressor
Surge in compressorSurge in compressor
Surge in compressor
 

Similar to Ex ic Intrinsic Safety New Protection Level

A users guide to intrinsic safety
A users guide to intrinsic safetyA users guide to intrinsic safety
A users guide to intrinsic safetyDavid Pires
 
Overvoltage Protection and Insulation Coordination in Power System.pdf
Overvoltage Protection and Insulation Coordination in Power System.pdfOvervoltage Protection and Insulation Coordination in Power System.pdf
Overvoltage Protection and Insulation Coordination in Power System.pdfAdamG25
 
Evaluating the Arc-Flash Protection Benefits of IEC 61850 Communication
Evaluating the Arc-Flash Protection Benefits of IEC 61850 CommunicationEvaluating the Arc-Flash Protection Benefits of IEC 61850 Communication
Evaluating the Arc-Flash Protection Benefits of IEC 61850 CommunicationSchneider Electric
 
Make India Safer with JMV LPS Ltd Electrical Equipment & Human Safety
Make India Safer with JMV LPS Ltd  Electrical Equipment & Human SafetyMake India Safer with JMV LPS Ltd  Electrical Equipment & Human Safety
Make India Safer with JMV LPS Ltd Electrical Equipment & Human SafetyMahesh Chandra Manav
 
Smart Grid Overvoltage Protection
Smart Grid Overvoltage ProtectionSmart Grid Overvoltage Protection
Smart Grid Overvoltage ProtectionMike Nager
 
E2S warning signals - intrinsically safe solutions
E2S warning signals - intrinsically safe solutionsE2S warning signals - intrinsically safe solutions
E2S warning signals - intrinsically safe solutionsE2S Warning Signals
 
Electrical Arc Flash Safety and Risk Management
Electrical Arc Flash Safety and Risk ManagementElectrical Arc Flash Safety and Risk Management
Electrical Arc Flash Safety and Risk ManagementSchneider Electric
 
Hazardous Area Location Guide - IEC NEC CEC & ATEX By Emerson Industrial
Hazardous Area Location Guide - IEC NEC CEC & ATEX By Emerson IndustrialHazardous Area Location Guide - IEC NEC CEC & ATEX By Emerson Industrial
Hazardous Area Location Guide - IEC NEC CEC & ATEX By Emerson IndustrialThorne & Derrick International
 
Worldwide Lightning called as Disaster not as Guest(SACHET)
Worldwide Lightning called as Disaster not as Guest(SACHET)Worldwide Lightning called as Disaster not as Guest(SACHET)
Worldwide Lightning called as Disaster not as Guest(SACHET)Mahesh Chandra Manav
 
Understanding Arc Flash
Understanding Arc FlashUnderstanding Arc Flash
Understanding Arc Flashmichaeljmack
 
Lightning and Surge Protection for Potentially Explosive Atmospheres
Lightning and Surge Protection for Potentially Explosive AtmospheresLightning and Surge Protection for Potentially Explosive Atmospheres
Lightning and Surge Protection for Potentially Explosive AtmospheresInstrument Specialties, Inc.
 
Understanding Arc Flash presentation engineering
Understanding Arc Flash presentation engineeringUnderstanding Arc Flash presentation engineering
Understanding Arc Flash presentation engineeringSheeda2
 
Webinar - Electrical Arc Flash Hazards - Is your company in compliance?
Webinar - Electrical Arc Flash Hazards - Is your company in compliance?Webinar - Electrical Arc Flash Hazards - Is your company in compliance?
Webinar - Electrical Arc Flash Hazards - Is your company in compliance?Leonardo ENERGY
 
2010 The Hebistor Device: Novel latch-up immune ESD Protection Clamp for High...
2010 The Hebistor Device: Novel latch-up immune ESD Protection Clamp for High...2010 The Hebistor Device: Novel latch-up immune ESD Protection Clamp for High...
2010 The Hebistor Device: Novel latch-up immune ESD Protection Clamp for High...Sofics
 
17thEdition.ppt
17thEdition.ppt17thEdition.ppt
17thEdition.pptChadWood16
 
Flexicon Flexible Conduit Solutions and Fittings for Hazardous Area - Low Fir...
Flexicon Flexible Conduit Solutions and Fittings for Hazardous Area - Low Fir...Flexicon Flexible Conduit Solutions and Fittings for Hazardous Area - Low Fir...
Flexicon Flexible Conduit Solutions and Fittings for Hazardous Area - Low Fir...Thorne & Derrick International
 
Molded Case Circuit Breakers Technical Information
Molded Case Circuit Breakers Technical InformationMolded Case Circuit Breakers Technical Information
Molded Case Circuit Breakers Technical InformationCTY TNHH HẠO PHƯƠNG
 

Similar to Ex ic Intrinsic Safety New Protection Level (20)

A users guide to intrinsic safety
A users guide to intrinsic safetyA users guide to intrinsic safety
A users guide to intrinsic safety
 
Overvoltage Protection and Insulation Coordination in Power System.pdf
Overvoltage Protection and Insulation Coordination in Power System.pdfOvervoltage Protection and Insulation Coordination in Power System.pdf
Overvoltage Protection and Insulation Coordination in Power System.pdf
 
Evaluating the Arc-Flash Protection Benefits of IEC 61850 Communication
Evaluating the Arc-Flash Protection Benefits of IEC 61850 CommunicationEvaluating the Arc-Flash Protection Benefits of IEC 61850 Communication
Evaluating the Arc-Flash Protection Benefits of IEC 61850 Communication
 
Make India Safer with JMV LPS Ltd Electrical Equipment & Human Safety
Make India Safer with JMV LPS Ltd  Electrical Equipment & Human SafetyMake India Safer with JMV LPS Ltd  Electrical Equipment & Human Safety
Make India Safer with JMV LPS Ltd Electrical Equipment & Human Safety
 
Smart Grid Overvoltage Protection
Smart Grid Overvoltage ProtectionSmart Grid Overvoltage Protection
Smart Grid Overvoltage Protection
 
E2S warning signals - intrinsically safe solutions
E2S warning signals - intrinsically safe solutionsE2S warning signals - intrinsically safe solutions
E2S warning signals - intrinsically safe solutions
 
Electrical Arc Flash Safety and Risk Management
Electrical Arc Flash Safety and Risk ManagementElectrical Arc Flash Safety and Risk Management
Electrical Arc Flash Safety and Risk Management
 
Hazardous Area Location Guide - IEC NEC CEC & ATEX By Emerson Industrial
Hazardous Area Location Guide - IEC NEC CEC & ATEX By Emerson IndustrialHazardous Area Location Guide - IEC NEC CEC & ATEX By Emerson Industrial
Hazardous Area Location Guide - IEC NEC CEC & ATEX By Emerson Industrial
 
What is an arc flash?
What is an arc flash? What is an arc flash?
What is an arc flash?
 
Worldwide Lightning called as Disaster not as Guest(SACHET)
Worldwide Lightning called as Disaster not as Guest(SACHET)Worldwide Lightning called as Disaster not as Guest(SACHET)
Worldwide Lightning called as Disaster not as Guest(SACHET)
 
Understanding Arc Flash
Understanding Arc FlashUnderstanding Arc Flash
Understanding Arc Flash
 
Lightning and Surge Protection for Potentially Explosive Atmospheres
Lightning and Surge Protection for Potentially Explosive AtmospheresLightning and Surge Protection for Potentially Explosive Atmospheres
Lightning and Surge Protection for Potentially Explosive Atmospheres
 
Understanding Arc Flash presentation engineering
Understanding Arc Flash presentation engineeringUnderstanding Arc Flash presentation engineering
Understanding Arc Flash presentation engineering
 
Webinar - Electrical Arc Flash Hazards - Is your company in compliance?
Webinar - Electrical Arc Flash Hazards - Is your company in compliance?Webinar - Electrical Arc Flash Hazards - Is your company in compliance?
Webinar - Electrical Arc Flash Hazards - Is your company in compliance?
 
ORBITAL ESE ACTIVE LIGHTNING ARRESTER
ORBITAL ESE ACTIVE LIGHTNING ARRESTERORBITAL ESE ACTIVE LIGHTNING ARRESTER
ORBITAL ESE ACTIVE LIGHTNING ARRESTER
 
2010 The Hebistor Device: Novel latch-up immune ESD Protection Clamp for High...
2010 The Hebistor Device: Novel latch-up immune ESD Protection Clamp for High...2010 The Hebistor Device: Novel latch-up immune ESD Protection Clamp for High...
2010 The Hebistor Device: Novel latch-up immune ESD Protection Clamp for High...
 
Electrical protection in mines John Ainsworth
Electrical protection in mines   John AinsworthElectrical protection in mines   John Ainsworth
Electrical protection in mines John Ainsworth
 
17thEdition.ppt
17thEdition.ppt17thEdition.ppt
17thEdition.ppt
 
Flexicon Flexible Conduit Solutions and Fittings for Hazardous Area - Low Fir...
Flexicon Flexible Conduit Solutions and Fittings for Hazardous Area - Low Fir...Flexicon Flexible Conduit Solutions and Fittings for Hazardous Area - Low Fir...
Flexicon Flexible Conduit Solutions and Fittings for Hazardous Area - Low Fir...
 
Molded Case Circuit Breakers Technical Information
Molded Case Circuit Breakers Technical InformationMolded Case Circuit Breakers Technical Information
Molded Case Circuit Breakers Technical Information
 

Recently uploaded

HONOR Veterans Event Keynote by Michael Hawkins
HONOR Veterans Event Keynote by Michael HawkinsHONOR Veterans Event Keynote by Michael Hawkins
HONOR Veterans Event Keynote by Michael HawkinsMichael W. Hawkins
 
Call Girls Electronic City Just Call 👗 7737669865 👗 Top Class Call Girl Servi...
Call Girls Electronic City Just Call 👗 7737669865 👗 Top Class Call Girl Servi...Call Girls Electronic City Just Call 👗 7737669865 👗 Top Class Call Girl Servi...
Call Girls Electronic City Just Call 👗 7737669865 👗 Top Class Call Girl Servi...amitlee9823
 
Value Proposition canvas- Customer needs and pains
Value Proposition canvas- Customer needs and painsValue Proposition canvas- Customer needs and pains
Value Proposition canvas- Customer needs and painsP&CO
 
Famous Olympic Siblings from the 21st Century
Famous Olympic Siblings from the 21st CenturyFamous Olympic Siblings from the 21st Century
Famous Olympic Siblings from the 21st Centuryrwgiffor
 
Cracking the Cultural Competence Code.pptx
Cracking the Cultural Competence Code.pptxCracking the Cultural Competence Code.pptx
Cracking the Cultural Competence Code.pptxWorkforce Group
 
The Path to Product Excellence: Avoiding Common Pitfalls and Enhancing Commun...
The Path to Product Excellence: Avoiding Common Pitfalls and Enhancing Commun...The Path to Product Excellence: Avoiding Common Pitfalls and Enhancing Commun...
The Path to Product Excellence: Avoiding Common Pitfalls and Enhancing Commun...Aggregage
 
Call Girls Jp Nagar Just Call 👗 7737669865 👗 Top Class Call Girl Service Bang...
Call Girls Jp Nagar Just Call 👗 7737669865 👗 Top Class Call Girl Service Bang...Call Girls Jp Nagar Just Call 👗 7737669865 👗 Top Class Call Girl Service Bang...
Call Girls Jp Nagar Just Call 👗 7737669865 👗 Top Class Call Girl Service Bang...amitlee9823
 
A DAY IN THE LIFE OF A SALESMAN / WOMAN
A DAY IN THE LIFE OF A  SALESMAN / WOMANA DAY IN THE LIFE OF A  SALESMAN / WOMAN
A DAY IN THE LIFE OF A SALESMAN / WOMANIlamathiKannappan
 
Monte Carlo simulation : Simulation using MCSM
Monte Carlo simulation : Simulation using MCSMMonte Carlo simulation : Simulation using MCSM
Monte Carlo simulation : Simulation using MCSMRavindra Nath Shukla
 
Mondelez State of Snacking and Future Trends 2023
Mondelez State of Snacking and Future Trends 2023Mondelez State of Snacking and Future Trends 2023
Mondelez State of Snacking and Future Trends 2023Neil Kimberley
 
Pharma Works Profile of Karan Communications
Pharma Works Profile of Karan CommunicationsPharma Works Profile of Karan Communications
Pharma Works Profile of Karan Communicationskarancommunications
 
7.pdf This presentation captures many uses and the significance of the number...
7.pdf This presentation captures many uses and the significance of the number...7.pdf This presentation captures many uses and the significance of the number...
7.pdf This presentation captures many uses and the significance of the number...Paul Menig
 
Call Girls Hebbal Just Call 👗 7737669865 👗 Top Class Call Girl Service Bangalore
Call Girls Hebbal Just Call 👗 7737669865 👗 Top Class Call Girl Service BangaloreCall Girls Hebbal Just Call 👗 7737669865 👗 Top Class Call Girl Service Bangalore
Call Girls Hebbal Just Call 👗 7737669865 👗 Top Class Call Girl Service Bangaloreamitlee9823
 
Lucknow 💋 Escorts in Lucknow - 450+ Call Girl Cash Payment 8923113531 Neha Th...
Lucknow 💋 Escorts in Lucknow - 450+ Call Girl Cash Payment 8923113531 Neha Th...Lucknow 💋 Escorts in Lucknow - 450+ Call Girl Cash Payment 8923113531 Neha Th...
Lucknow 💋 Escorts in Lucknow - 450+ Call Girl Cash Payment 8923113531 Neha Th...anilsa9823
 
Monthly Social Media Update April 2024 pptx.pptx
Monthly Social Media Update April 2024 pptx.pptxMonthly Social Media Update April 2024 pptx.pptx
Monthly Social Media Update April 2024 pptx.pptxAndy Lambert
 
Call Girls In Panjim North Goa 9971646499 Genuine Service
Call Girls In Panjim North Goa 9971646499 Genuine ServiceCall Girls In Panjim North Goa 9971646499 Genuine Service
Call Girls In Panjim North Goa 9971646499 Genuine Serviceritikaroy0888
 
Regression analysis: Simple Linear Regression Multiple Linear Regression
Regression analysis:  Simple Linear Regression Multiple Linear RegressionRegression analysis:  Simple Linear Regression Multiple Linear Regression
Regression analysis: Simple Linear Regression Multiple Linear RegressionRavindra Nath Shukla
 
Dr. Admir Softic_ presentation_Green Club_ENG.pdf
Dr. Admir Softic_ presentation_Green Club_ENG.pdfDr. Admir Softic_ presentation_Green Club_ENG.pdf
Dr. Admir Softic_ presentation_Green Club_ENG.pdfAdmir Softic
 
B.COM Unit – 4 ( CORPORATE SOCIAL RESPONSIBILITY ( CSR ).pptx
B.COM Unit – 4 ( CORPORATE SOCIAL RESPONSIBILITY ( CSR ).pptxB.COM Unit – 4 ( CORPORATE SOCIAL RESPONSIBILITY ( CSR ).pptx
B.COM Unit – 4 ( CORPORATE SOCIAL RESPONSIBILITY ( CSR ).pptxpriyanshujha201
 
Russian Call Girls In Gurgaon ❤️8448577510 ⊹Best Escorts Service In 24/7 Delh...
Russian Call Girls In Gurgaon ❤️8448577510 ⊹Best Escorts Service In 24/7 Delh...Russian Call Girls In Gurgaon ❤️8448577510 ⊹Best Escorts Service In 24/7 Delh...
Russian Call Girls In Gurgaon ❤️8448577510 ⊹Best Escorts Service In 24/7 Delh...lizamodels9
 

Recently uploaded (20)

HONOR Veterans Event Keynote by Michael Hawkins
HONOR Veterans Event Keynote by Michael HawkinsHONOR Veterans Event Keynote by Michael Hawkins
HONOR Veterans Event Keynote by Michael Hawkins
 
Call Girls Electronic City Just Call 👗 7737669865 👗 Top Class Call Girl Servi...
Call Girls Electronic City Just Call 👗 7737669865 👗 Top Class Call Girl Servi...Call Girls Electronic City Just Call 👗 7737669865 👗 Top Class Call Girl Servi...
Call Girls Electronic City Just Call 👗 7737669865 👗 Top Class Call Girl Servi...
 
Value Proposition canvas- Customer needs and pains
Value Proposition canvas- Customer needs and painsValue Proposition canvas- Customer needs and pains
Value Proposition canvas- Customer needs and pains
 
Famous Olympic Siblings from the 21st Century
Famous Olympic Siblings from the 21st CenturyFamous Olympic Siblings from the 21st Century
Famous Olympic Siblings from the 21st Century
 
Cracking the Cultural Competence Code.pptx
Cracking the Cultural Competence Code.pptxCracking the Cultural Competence Code.pptx
Cracking the Cultural Competence Code.pptx
 
The Path to Product Excellence: Avoiding Common Pitfalls and Enhancing Commun...
The Path to Product Excellence: Avoiding Common Pitfalls and Enhancing Commun...The Path to Product Excellence: Avoiding Common Pitfalls and Enhancing Commun...
The Path to Product Excellence: Avoiding Common Pitfalls and Enhancing Commun...
 
Call Girls Jp Nagar Just Call 👗 7737669865 👗 Top Class Call Girl Service Bang...
Call Girls Jp Nagar Just Call 👗 7737669865 👗 Top Class Call Girl Service Bang...Call Girls Jp Nagar Just Call 👗 7737669865 👗 Top Class Call Girl Service Bang...
Call Girls Jp Nagar Just Call 👗 7737669865 👗 Top Class Call Girl Service Bang...
 
A DAY IN THE LIFE OF A SALESMAN / WOMAN
A DAY IN THE LIFE OF A  SALESMAN / WOMANA DAY IN THE LIFE OF A  SALESMAN / WOMAN
A DAY IN THE LIFE OF A SALESMAN / WOMAN
 
Monte Carlo simulation : Simulation using MCSM
Monte Carlo simulation : Simulation using MCSMMonte Carlo simulation : Simulation using MCSM
Monte Carlo simulation : Simulation using MCSM
 
Mondelez State of Snacking and Future Trends 2023
Mondelez State of Snacking and Future Trends 2023Mondelez State of Snacking and Future Trends 2023
Mondelez State of Snacking and Future Trends 2023
 
Pharma Works Profile of Karan Communications
Pharma Works Profile of Karan CommunicationsPharma Works Profile of Karan Communications
Pharma Works Profile of Karan Communications
 
7.pdf This presentation captures many uses and the significance of the number...
7.pdf This presentation captures many uses and the significance of the number...7.pdf This presentation captures many uses and the significance of the number...
7.pdf This presentation captures many uses and the significance of the number...
 
Call Girls Hebbal Just Call 👗 7737669865 👗 Top Class Call Girl Service Bangalore
Call Girls Hebbal Just Call 👗 7737669865 👗 Top Class Call Girl Service BangaloreCall Girls Hebbal Just Call 👗 7737669865 👗 Top Class Call Girl Service Bangalore
Call Girls Hebbal Just Call 👗 7737669865 👗 Top Class Call Girl Service Bangalore
 
Lucknow 💋 Escorts in Lucknow - 450+ Call Girl Cash Payment 8923113531 Neha Th...
Lucknow 💋 Escorts in Lucknow - 450+ Call Girl Cash Payment 8923113531 Neha Th...Lucknow 💋 Escorts in Lucknow - 450+ Call Girl Cash Payment 8923113531 Neha Th...
Lucknow 💋 Escorts in Lucknow - 450+ Call Girl Cash Payment 8923113531 Neha Th...
 
Monthly Social Media Update April 2024 pptx.pptx
Monthly Social Media Update April 2024 pptx.pptxMonthly Social Media Update April 2024 pptx.pptx
Monthly Social Media Update April 2024 pptx.pptx
 
Call Girls In Panjim North Goa 9971646499 Genuine Service
Call Girls In Panjim North Goa 9971646499 Genuine ServiceCall Girls In Panjim North Goa 9971646499 Genuine Service
Call Girls In Panjim North Goa 9971646499 Genuine Service
 
Regression analysis: Simple Linear Regression Multiple Linear Regression
Regression analysis:  Simple Linear Regression Multiple Linear RegressionRegression analysis:  Simple Linear Regression Multiple Linear Regression
Regression analysis: Simple Linear Regression Multiple Linear Regression
 
Dr. Admir Softic_ presentation_Green Club_ENG.pdf
Dr. Admir Softic_ presentation_Green Club_ENG.pdfDr. Admir Softic_ presentation_Green Club_ENG.pdf
Dr. Admir Softic_ presentation_Green Club_ENG.pdf
 
B.COM Unit – 4 ( CORPORATE SOCIAL RESPONSIBILITY ( CSR ).pptx
B.COM Unit – 4 ( CORPORATE SOCIAL RESPONSIBILITY ( CSR ).pptxB.COM Unit – 4 ( CORPORATE SOCIAL RESPONSIBILITY ( CSR ).pptx
B.COM Unit – 4 ( CORPORATE SOCIAL RESPONSIBILITY ( CSR ).pptx
 
Russian Call Girls In Gurgaon ❤️8448577510 ⊹Best Escorts Service In 24/7 Delh...
Russian Call Girls In Gurgaon ❤️8448577510 ⊹Best Escorts Service In 24/7 Delh...Russian Call Girls In Gurgaon ❤️8448577510 ⊹Best Escorts Service In 24/7 Delh...
Russian Call Girls In Gurgaon ❤️8448577510 ⊹Best Escorts Service In 24/7 Delh...
 

Ex ic Intrinsic Safety New Protection Level

  • 1. Ex ic Intrinsic Safety’s New Protection Level Intrinsic Safety Solutions January 2015 WP EX ic DRAFT - 08 January 2015 Synopsis The protection of electrical apparatus for use in flammable atmospheres is embracing a new technique: Ex ic. As a logical extension of the existing intrinsic safety concept, it formalises the application of intrinsic safety in Zone 2 hazardous areas, but users and manufacturers alike are wrestling with the details. The discussion centres as much on the withdrawal of the Ex nL technique, as on the application of Ex ic which replaces it. The paper deals primarily with the impact on countries that follow IEC and ATEX practice, but there are parallels with the ‘non- incendive’ technique that is adopted in North America. What is Ex ic ? Ex ic is a form of intrinsic safety protection for electrical apparatus in flammable atmospheres. It is a logical extension of the long-established Ex ia and Ex ib protection levels, and is suitable for use in, or connection into, Zone 2 hazardous areas where there is a low probability of a flammable risk. Ex ic retains the unique characteristic of all intrinsic safety systems in which the wiring and field apparatus may be ‘live-worked’ in the presence of a flammable atmosphere. The safety factors and equipment construction requirements are however more relaxed than for the Ex ia and ib protection levels, to take account of the lower risks associated with Zone 2. In common with the other protection levels, Ex ic is best suited to instrumentation circuits, where the levels of voltage and current are consistent with those permitted by intrinsic safety, although Ex ic can take advantage of the Zone 2 relaxations to drive somewhat larger loads. Zone 0 In which an explosive gas-air mixture is continuously pres- ent or present for long periods Zone 1 In which an explosive gas-air mixture is likely to occur in normal operation Zone 2 In which an explosive gas-air mixture is not likely occur in normal operation, and if it occurs it will exist only for a short time Level of protection Zone of use Fault Count Ex ia Zone 0 Safe with 2 countable faults Ex ib Zone 1 Safe with 1 countable fault Ex ic Zone 2 Safe with no countable faults (ie safe in normal operation) The position of Ex ic in the Intrinsic Safety FamilyThe IEC Area Classification System
  • 2. 2 WP EX IC DRAFT - 08 January 2015 The concept of a third level of protection for intrinsic safety has existed for several decades, but only recently has it been formally adopted into the major standards systems in common use worldwide. Meanwhile, other methods of protection had filled the gap. In particular, Ex nL, a subset of the ‘safe in normal operation’ standard, Ex n, had provided a workable but somewhat loosely defined alternative. Ex nL (where the L referred to its energy- limited provenance), borrowed heavily from the published intrinsic safety ignition data to provide a method of protection in which instrumentation circuits could be live-worked in Zone 2. In North America, the ‘nonincendive’ method also delivers a roughly equivalent approach as part of its wide portfolio: the ‘nonincendive with field wiring parameters’ technique allows limited live-working in Division 2 hazardous areas. Method of Protection Ex code Permitted in: Zone 0 Zone 1 Zone 2 Encapsulation ma 3 3 3 mb 3 3 Oil immersion o 3 3 Powder filling q 3 3 Pressurisation p 3 3 Flameproof da 3 3 3 db 3 3 dc 3 Intrinsic safety ia 3 3 3 ib 3 3 ic 3 Increased safety e 3 3 Type of protection “n” nA 3 nR 3 nC 3 The IEC methods of protection and permitted Zone of use So why have things changed at last? One major factor is that Ex nL had for a long time been an uncomfortable bed-fellow with the other protection concepts that were part of the overall Ex n concept. Whereas Ex nL conformed to the relatively low voltage and current levels of energy-limitation, there were no such restrictions for the Ex nA (non-arcing), Ex nC (containment) and Ex nR (restricted breathing) techniques, which were therefore appropriate for heavy-current switchgear and rotating machines. Ex nL was more concerned with milliwatts than with kilowatts. The relevant expertise on low power circuits already existed within the IEC’s intrinsic safety committee, so as long ago as 2003, the IEC main technical committee TC31 decided to discontinue the Ex nL technique. Another influence has been the introduction of IEC ‘Equipment Protection Levels’, which formalise the application of the Ex methods to the different hazardous area Zones using the a, b and c suffices for Zones 0, 1 and 2 respectively. Ex ic Intrinsic Safety’s New Protection Level
  • 3. 3WP Ex ic DRAFT - 08 January 2015 These also tie in with the ATEX ‘Categories’ 1, 2 and 3. So, in recognition that Ex nL already owed much of its provenance to intrinsic safety, the Ex nL technique was divested from Ex n and reinstated as Ex ic. Consequently, Ex ic was introduced into the 2006 version of the intrinsic safety standard, IEC 60079- 11 Edition 5.0 (and re-confirmed in the 2011 version, Edition 6.0), and the Ex nL sub- category was removed from the 2010 version of the IEC 60079-15 apparatus standard for Ex n. Other relevant intrinsic safety standards, such as the systems standard (IEC 60079-25) have also been updated to take account of Ex ic. These decisions have affected equipment manufacturers and end-users alike. From April 2013, manufacturers were no longer permitted to put ATEX-certified Ex nL apparatus onto the market. Existing Ex nL installations can remain in service, but any new projects that would previously have adopted Ex nL must now be protected by an alternative means - including Ex ic if suitably certified apparatus is available. Zone ATEX Category IEC Protection Level Zone 0 1 a Zone 1 2 b Zone 2 3 c ATEX Categories and IEC Protection Levels according to Hazardous Area Zone The same, but different Ex nL and Ex ic share many underpinning principles for the explosion protection of low-power electrical apparatus. They are both based on the concept of energy- limitation, by which the levels of voltage and current present in the field wiring are incapable of causing ignition even if the circuits are shorted or broken. They both apply a unity ‘factor of safety’ Note 1 to the current level, and both are restricted to use in Zone 2. The migration to the parent technique of intrinsic safety has however created a number of detailed differences as a result of applying the broader intrinsic safety requirements (ie those created for ia and ib circuits) to Ex ic. One notable difference relates to the required separation distance between the terminals of intrinsically safe and non- intrinsically safe apparatus, for example where electronic modules and field-wiring terminals are installed onto DIN-rail in equipment cabinets. Ex nL was classified as a non-IS technique and hence its terminals required minimal separation from those of other non-IS circuits, but they were required to be separated by 50mm from IS circuits. However, Ex ic terminals are IS, so the converse is true: they must have the 50mm separation from non-IS circuits, but not from other (ie Ex ia or ib) IS circuits. Ex nL Ex ic Ex nL 1.3mm Note 2 50mm Other non-IS circuits 1.3mm Note 2 50mm All IS circuits (including ia, ib and ic) 50mm 6mm Required separation distances between terminals of Ex ic, Ex nL and other apparatus
  • 4. 4 WP EX IC DRAFT - 08 January 2015 Other differences include: • The combinations of protection types that can occupy the same multi-core cable (Ex ic can share the same multi-core as other IS circuits, but nL cannot); • The constructional requirements of transformers; • The values of ‘creepage and clearance’ between tracks on printed circuit boards. Such changes mean that apparatus that was previously certified Ex nL may not automatically be re-certifiable as Ex ic, for example if the physical positioning of the electrical connections fall foul of the connector separation requirement. Win some, lose some Some practitioners will see the imposition of intrinsic safety’s broader requirements as a negative step, and will bemoan the loss of flexibility that accompanied Ex nL. But bringing Ex ic into the intrinsic safety fold can be argued to have a number of significant advantages: • Installation and maintenance requirements are now defined by Intrinsic Safety’s clear, internationally recognized standards and codes of practice; • More power is available for IS circuits, as a result of the unity factor of safety on current and a single active current limit; • Intrinsic Safety is consolidated as a protection method for all hazardous area Zones; • Combinations of Ex ia, ib and ic apparatus are permitted in the same system, subject to the Zone of use. • The Temperature Classification (T Class) for Ex ic is easy to define, because the apparatus is assumed to be in ‘normal operation’. A case study: Ex ic in Fieldbus Networks A common application of Ex nL has been in the design and use of FOUNDATIONTM fieldbus networks for instrumentation in the process industries. Typically, the ‘spur’ connections of field device couplers (sometimes referred to as wiring hubs) were certified as Ex nL associated apparatus, to allow the spur wiring to be live-worked when connected to suitably certified field instruments in a Zone 2 hazardous area. Historically the field instruments connected to the spurs were certified either as Ex nL apparatus, or as Ex ia or ib on the basis that the intrinsic safety construction requirements exceed those of Ex nL. This approach delivered a flexible, low cost installation, where the field instruments could be easily replaced without needing to power down the network or to declare that the area as gas-free. The idea of Ex ic is logical and relatively easy to grasp: a new level of intrinsic safety that is safe in normal operation, but where open and short-circuits in the field wiring are included in the definition of “normal”. This means that the wiring can be live-worked. Ex ic Intrinsic Safety’s New Protection Level
  • 5. 5WP Ex ic DRAFT - 08 January 2015 The safety of the Ex nL spurs was achieved using energy-limitation, by capping the voltage and current entering the spur circuit: the spur voltage was defined by the maximum output of the network power supply, and current limitation was provided by the individual spur short-circuit protection circuits in the device couplers. Tests performed during the certification process would have confirmed that opening or shorting the spur connections was incapable of igniting the most easily ignitable gas- air mixture, as defined by the intended Gas Group. Stored energy in the spur cables was also considered by defining appropriate cable parameters. Zone 2 Hazardous Area Ex nA [nL] apparatus Fieldbus spur Ex nL Ex nL or Ex i certified Fieldbus instruments Ex nA trunk, with voltage limitation in accordance wth Ex nL Current limitation in accordance with Ex nL Fieldbus Control system I/O card Fieldbus Power supply with voltage limitation Device Coupler With Ex nL, the fieldbus application used the power supply’s inherent voltage limitation With the migration to Ex ic, the essential voltage and current limitation still apply, except that they now have to comply with the Ex ic requirements of IEC 60079-11. At face value, the transition would appear to be relatively trivial, but the detail changes have a subtle, and in some cases radical effect on the hardware design. A particular area of interest is the fieldbus trunk (the cable that carries power from the control-room mounted power supply to the field-mounted device coupler). Under the Ex nL spur regime, the trunk wiring could be declared as Ex nA (ie non-sparking, meaning that it is designed and installed such that sparking cannot take place), but with voltage limitation in accordance with Ex nL.
  • 6. 6 WP EX IC DRAFT - 08 January 2015 This raised few eyebrows because there was no essential incompatibility between the two Ex n techniques in this application. However, the question arises whether the trunk cable can be declared as Ex nA but with intrinsically safe (ie Ex ic) voltage limitation. Is the trunk now an intrinsically safe circuit or not? Can it be half intrinsically safe, and if so how would it be treated in terms of installation and separation from other circuits? Zone 2 Hazardous Area Ex nA [ic] apparatus Fieldbus spur Ex ic Ex i certified Fieldbus instruments Ex nA trunk Current limitation in accordance with Ex ic Fieldbus Control system I/O card Fieldbus Power supply Device Coupler Ex ic voltage limitation With Ex ic, a separate voltage limiter is inserted to avoid an ambiguous Ex nA/ic classification for the fieldbus trunk This particular point demonstrates how the looser interpretation of Ex nL permitted a real-life application, whereas Ex ic requires a more rigorous approach. As a manufacturer of field wiring components for Foundation fieldbus networks, the author’s company has considered carefully how to develop a safe and workable network with Ex ic spurs. The primary design requirements were: • To attempt to comply with the safest interpretation of Ex ic requirements, in particular where the certification organisations (notified bodies) held differing views; • To unambiguously identify the Ex method of protection invoked for each part of the network, so that the user can install and maintain it appropriately. Ex ic Intrinsic Safety’s New Protection Level
  • 7. 7WP Ex ic DRAFT - 08 January 2015 The resulting solution, and its comparison with the preceding Ex nL implementation, provides a useful window on how the migration to Ex ic may affect other areas of instrumentation. One particular characteristic of the fieldbus application is to move the circuitry that performs the Ex ic voltage limitation from the network power supply to a separate unit located in the field, close to the device coupler. This has the benefit of rendering the trunk entirely Ex nA in certification terms, meaning that it does not attract any requirement to separate it from other non-intrinsically safe circuits. Importantly, this avoids the need to treat the trunk wiring (and its associated terminals) as intrinsically safe where it weaves its path through the control room marshalling cabinet. Alternative solutions with the Ex ic voltage limitation in the power supply have to provide the necessary 50mm separation between the trunk terminals and those of other non-IS circuits - assuming the installer has read the details in the vendor’s instruction manual! A further benefit of classifying the trunk as Ex nA (and only nA), is that other non- intrinsically safe field devices can be connected to the trunk via a conventional device coupler, allowing a mix of Ex nA, Ex d and Ex i instruments on the same segment. This arrangement is questionable if the trunk is classified as part Ex nA, part Ex ic. Whether it was permissible under Ex nL rules is also difficult to say for certain, since the relevant installation requirements were poorly defined. Zone 2 Hazardous Area Ex nA [ic] apparatus Fieldbus spur Ex ic Ex i certified Fieldbus instruments Fieldbus Control system I/O card Fieldbus Power supply Device Coupler Ex ic voltage limitation Ex d or Ex nA certified Fieldbus instrument A benefit of defining the trunk as Ex nA is that Ex d or Ex nA field devices can also be connected to the segment
  • 8. 8 WP EX IC DRAFT - 08 January 2015 Managing the transition As the instrumentation community adapts to the brave new world of Ex ic, other questions come to mind. Can apparatus certified as Ex nL be used in Ex ic circuits, and vice-versa? Such questions are most likely to be relevant to existing ‘nL’ installations, or to the re-use of ‘nL’ certified field instruments. New installations will be driven entirely to ‘ic’ because of the unavailability of ‘nL’ certified apparatus. However, the use of ‘nL’ apparatus in ‘ic’ systems does already have a precedent, since it is covered in the FISCO (Fieldbus Intrinsically Safe Concept) annex of the system standard IEC 60079-25. This can be extended to other fieldbus systems, and arguably also to other non-fieldbus Ex ic circuits. If the ‘nL’ apparatus parameters are well defined, it can be used. The analysis should be recorded in the system documentation. In practice, this is most likely to apply to the use of an Ex nL certified field transmitter in an Ex ic circuit. Where the safety parameters of an ‘ic’ apparatus are compatible with the requirements of the system (they may be more detailed than those of the ‘nL’ apparatus), then the ‘ic’ apparatus can be used in an ‘nL’ system. Again, the change should be justified and recorded in the system documentation. This would cover the use of an ‘ic’ field transmitter in an existing ‘nL’ installation. The details of such issues are still under discussion in hazardous area forums. For example, voices within the IEC ‘maintenance team’ for the intrinsic safety standard are arguing that the new situation is just too complicated. Their point is that the rules for Ex ic should have been much more akin to those for Ex nL: in effect, a re-naming of the technique but not a complete re-definition. Could there yet be a ‘U-turn’? Possibly, but only in the lengthy timescales needed to up-issue an Ex standard. Just to keep everyone on their toes, another important change is pending in the certification world: Ex nA will itself be withdrawn from the IEC 60079-15 standard, and replaced by a new “Ex ec” level of protection in IEC 60079-7 for ‘increased safety’ apparatus. In common with Ex ic, the use of Level of Protection ‘c’ is invoked for Zone 2, but this time it is being applied to normally non-sparking apparatus and circuits. Again, although the inherent characteristics of nA will transfer to a new level in the increased safety standard, there will be detail differences that mean existing nA apparatus may not be automatically re-certifiable as Ex ec. It is probable that the new edition of the IEC 60079-7 standard containing Ex ec will appear at the end of 2015, and become an ATEX harmonised standard possibly mid-2016. Ex ic Intrinsic Safety’s New Protection Level
  • 9. 9WP Ex ic DRAFT - 08 January 2015 In summary The idea of Ex ic is logical and relatively easy to grasp: a new level of intrinsic safety that is safe in normal operation, but where open- and short-circuits in the field wiring are included in the definition of “normal”. This means that the wiring can be live- worked. It is restricted to Zone 2, in which any flammable atmosphere is fleeting. Its IEC predecessor, Ex nL, embraced the same concept but was adopted with more flexibility because, unlike intrinsic safety, the overall installation requirements were less well defined. The withdrawal of Ex nL will therefore leave a gap that Ex ic may find difficult to fill, especially where manufacturers find that existing Ex nL products cannot be automatically re-certified as Ex ic. It may take some time for the dust to settle. The formalisation of the design, installation and maintenance rules that follow from the absorption of Ex ic into the broader world of intrinsic safety are however to be welcomed. It would difficult to point to ways in which Ex nL was less safe, but it was less well understood (and therefore more vulnerable to widely different interpretations) than intrinsic safety. The situation is further complicated by the fact that the standards organisations are still debating whether the technical requirements of Ex ic are too onerous - even after the new standard has been published. So it is yet possible that future versions of the intrinsic safety standard will relax the rules and move the goalposts again!
  • 10. 10 WP EX IC DRAFT - 08 January 2015 Notes 1. The ‘factor of safety’ refers to a safety margin that is applied to the permitted current level. For a given voltage level, the published ‘ignition curves’ define the maximum current at which ignition does not occur. With intrinsic safety protection levels Ex ia and ib, the actual current is reduced by 50%; with Ex ic, no margin is applied. 2. The separation distance depends on the voltage. For Ex nL circuits defined as ‘low power’ it is zero. For up to 32V, the required separation is 1.3mm. Ex ic Intrinsic Safety’s New Protection Level
  • 11. 11WP Ex ic DRAFT - 08 January 2015
  • 12. DRAFT - 08 January 2015 EUROPE (EMEA): +44 (0)1582 723633 mtlenquiry@eaton.com THE AMERICAS: +1 800 835 7075 mtl-us-info@eaton.com ASIA-PACIFIC: +65 6 645 9888 sales.mtlsing@eaton.com The given data is only intended as a product description and should not be regarded as a legal warranty of properties or guarantee. In the interest of further technical developments, we reserve the right to make design changes. Measurement Technology Limited, Great Marlings, Butterfield, Luton Beds, LU2 8DL, UK. Tel: + 44 (0)1582 723633 Fax: + 44 (0)1582 422283 E-mail: mtlenquiry@eaton.com www.mtl-inst.com © 2014 MTL All Rights Reserved Publication No. WP Ex ic January 2015 AUSTRALIA MTL Instruments Pty Ltd, 205-209 Woodpark Road, Smithfield, New South Wales 2164, Australia Tel: + 61 1300 308 374 Fax: + 61 1300 308 463 E-mail: mtlsalesanz@eaton.com BeNeLux MTL Instruments BV Terheijdenseweg 465, 4825 BK Breda The Netherlands Tel: + 31 (0) 76 7505360 Fax: +31 (0) 76 7505370 E-mail: mtl.benelux@eaton.com CHINA Cooper Electric (Shanghai) Co. Ltd 955 Shengli Road, Heqing Industrial Park Pudong New Area, Shanghai 201201 Tel: + 86 2128993817 Fax: + 86 2128993992 E-mail: mtl-cn@eaton.com FRANCE MTL Instruments sarl, 7 rue des Rosiéristes, 69410 Champagne au Mont d’Or France Tel: + 33 (0)4 37 46 16 70 Fax: +33 (0)4 37 46 17 20 E-mail: mtlfrance@eaton.com GERMANY MTL Instruments GmbH, Heinrich-Hertz-Str. 12, 50170 Kerpen, Germany Tel: + 49 (0)22 73 98 12 - 0 Fax: + 49 (0)22 73 98 12 - 2 00 E-mail: mtlgmbh@eaton.com INDIA MTL India, No.36, Nehru Street, Off Old Mahabalipuram Road Sholinganallur, Chennai - 600 119, India Tel: + 91 (0) 44 24501660 /24501857 Fax: + 91 (0) 44 24501463 E-mail: mtlindiasales@eaton.com ITALY MTL Italia srl, Via A. Meucci, 10, I-20094 Corsico (MI), Italy Tel: + 39 (0)2 61802011 Fax: + 39 (0)2 61294560 E-mail: chmninfo@eaton.com JAPAN Cooper Crouse-Hinds Japan KK, MT Building 3F, 2-7-5 Shiba Daimon, Minato-ku, Tokyo, Japan 105-0012 Tel: + 81 (0)3 6430 3128 Fax: + 81 (0)3 6430 3129 E-mail: mtl-jp@eaton.com NORWAY Norex AS Fekjan 7c, Postboks 147, N-1378 Nesbru, Norway Tel: + 47 66 77 43 80 Fax: + 47 66 84 55 33 E-mail: info@norex.no SINGAPORE Cooper Crouse-Hinds Pte Ltd No 2 Serangoon North Avenue 5, #06-01 Fu Yu Building Singapore 554911 Tel: + 65 6 645 9888 Fax: + 65 6 487 7997 E-mail: sales.mtlsing@eaton.com SOUTH KOREA Cooper Crouse-Hinds Korea 12F, Vision Tower, 707-2 Yeoksam-Dong Gangnam-Gu, Seoul 135-080, South Korea. Tel: + 82 2 538 3481 Fax: + 82 2 538 3505 E-mail: mtl-korea@eaton.com UNITED ARAB EMIRATES Cooper Industries/Eaton Corporation Office 205/206, 2nd Floor SJ Towers, off. Old Airport Road, Abu Dhabi, United Arab Emirates Tel: + 971 2 44 66 840 Fax: + 971 2 44 66 841 E-mail: mtlgulf@eaton.com UNITED KINGDOM Measurement Technology Limited, Great Marlings, Butterfield, Luton Beds LU2 8DL Tel: + 44 (0)1582 723633 Fax: + 44 (0)1582 422283 E-mail: mtlenquiry@eaton.com AMERICAS Cooper Crouse-Hinds MTL Inc. 3413 N. Sam Houston Parkway W. Suite 210, Houston TX 77086, USA Tel: + 1 281-571-8065 Fax: + 1 281-571-8069 E-mail: mtl-us-info@eaton.com