1. 1358-SERIES Data Sheet Ref. No : SU-1358-00002
Electrically Operated Plastic Ball MODEL NO.: SUDE
Valve Technical Specifications 135850PVCPVCTONFBSPSD- PUNE / BANGALORE
1000-052LS
Quotation Ref. No
Quotation Date
1. ITEM ASSEMBLY OF 2 WAY PLASTIC BALL VALVE FITTED
WITH SINGLE PHASE QUARTER TURN ELECTRIC
ACTUATOR
2. MAKE SUDE
3 APPLICATION
6 TECHNICAL SPECIFICATION OF 2 WAY BALL VALVE
Valve Size 50mm
End connection BSP Screwed
Body Material PVC
Ball Material PVC
Seating material Teflon
Flowing medium Acid
Pressure 10 Bar
Temperature Ambient
Characteristic On/Off Type
Sdtork Make Single Phase Quarter Turn Electric
Fitted with
Actuator Supply Voltage 230 V AC.
ACTUATOR DETAILS
3.1 Model SD-1000-05
3.2 Output motion type
3.3 Output Torque ( Nm )
3.4 Output speed ( Sec/90 °)
3.5 Manual hand wheel PROVIDED
3.6 Travel limit switches Type : 1 NO + 1 NC, change over contact, contact rating: 5 A, 230
2 Nos V AC
3.7 Torque limit switches Not required, AS 1000-series actuator are provided with stall duty
motor
3.8 Local indicator PROVIDED
3.9 Class of Protection IP67
3.10 Weight of the actuator (Kgs.)
3.11 Duty
3.12 Mounting
3.14 G. A. Drawing Reference No
3.15 Electrical Wiring Diagram Ref, No
3.16 Weight of Actuator – Kgs
MOTOR DETAILS
4.1 Type Reversible Single Phase Synchronous Stall Duty Motor
4.2 Supply 230 V +/- 10 %, 50 Hz +/- 5 % AC Supply
4.3 Duty S2-10 min / S-4-30 % 1200 Cycles/ hr.
4.4 Insulation Class F
4.5 Rating ( Watts)
OPTIONAL ACCESSORIES
2. 5.1 Feedback Out put : 100-235 Ohms Not Provided
Potentiometer
5.2 Additional Limit Qty : 2 nos. Provided
Switches Type : 1 NO + 1 NC, Change over contact,
Contact rating: 5 A, 230VAC
5.3 Two Wire Transmitter Type : Two wire, Actuator mounted Not Provided
Supply : 12-36 VDC, Output : 4-20 m A
5.4 Remote Position Available in servo controller Not Provided
indicator Digital : 0-100 %
5.5 Servo controller Input signal : 4-20 m A, Output : 4-20 m A Not Provided
(Valve positioner) Feed back : 0-500 Ohms, supply 230 V AC,
Panel Mounted This will have auto calibration facility.
5.6 Interface Card Input signal : 4-20 m A, Not Provided
Actuator Mounted Feed back : 100-235 Ohms,
5.6 Control Panel This will consist of 2 nos. of Control Relay Not Provided
with required control voltage (If not specify,
control voltage will be 230 VAC ) Auto /
Manual selector switch, Open/Close push
buttons, emergency stop button & MCB.
5.7 Local Push Button This will consist of Auto /Off / Manual Not Provided
Station selector switch, Open/Close push buttons.
6 GENERAL POINTS
6.1 Inspection By Customer at our works
6.2 T. C.& Manuals 2 Sets with unit
6.3 Warranty 18 months from the date of supply or 12 months from the date of installation
which ever is earlier.
6.4 Packing Thermo cool Packing Housed in corrugated Box
SPECIAL NOTE :