2. SICAM SCC - SIMATIC WinCC based scalable HMI with efficient engineering for
energy automation applications at utilities and industrial enterprise.
The process and visualization system SICAM SCC is a central element of energy
automation solutions.
The system is independent of the substation technology installed. SICAM SCC is
compatible with the SICAM PAS Power Automation System, the products of the
SICAM RTUs line. And in case you are not using a substation controller in your station:
SICAM SCC communicates directly with bay units and protection devices that support
the IEC 61850 communication standard.
As a result it can be used as an overall HMI system for devices. The SIMATIC WinCC
based SICAM SCC system is scalable and offers efficient engineering for energy
automation applications at utilities and industrial enterprises.
Description
3. SICAM SCC – based on SIMATIC WinCC
common HMI for SICAM and SIMATIC SICAM SCC is based on the SIMATIC WinCC
system, one of the world leading process visualization systems, adding the functions
required for use as substation operating system of the electric process in high-voltage
and medium-voltage systems. The compatibility with SIMATIC WinCC allows SICAM
SCC to be used as an add-on together with SIMATIC WinCC on one computer. This
enables an integrated system solution for visualizing and controlling the industrial
manufacturing processes using SIMATIC automation devices (e.g. S7 and PCS7) and
the electric energy process (e.g. SICAM PAS).
SICAM SCC – functions for use with SICAM and IEC61850
SICAM SCC is tailored to be used in energy applications supporting operators with
the task of optimizing system management. It provides a fast and clear overview of
the system operating states. The specific properties of the HV and MV switchgear in
control and monitoring direction (double commands and double-point indications) are
optimally implemented in the indication lists and the graphic process visualization.
Detail
4. SICAM SCC – shared substation automation functions with SICAM PAS
Additional functions are supported when using the system in conjunction with SICAM
PAS: If, for example, maintenance or tests have to be carried out for the process
domain of a bay controller, it may not be desirable that status changes are actually
processed by the SICAM PAS substation automation processing functions nor logged
in the HMI. This can be implemented easily by activating the bay blocking function.
The telecontrol blocking function can be used if you want status changes to be
processed in the station but not transmitted to the higher-level control center.
Substations are usually controlled from the higher-level control centers, whereas
switching commands are to be rejected by the station's internal HMI; the switching
authority is assigned to the higher-level control center. If control from the HMI is
required for operational management reasons, the switching authority can be
obtained. If the substation is connected to several control centers, the switching
authority can also be assigned to specific channels. Additionally, different switching
authorities can be used e.g. for the different voltage levels
Detail
5. SICAM SCC – from process visualization to topological coloring
IndustrialX controls are used to control and monitor the switchgear in the fully
graphical process images (single-line diagrams). These switchgear objects support 4
different display modes (IEC, DIN, SINAUT LSA, SICAM) for circuit-breakers and
disconnectors. In addition, project-specific bitmaps can be defined to represent the
switchgear devices and link them with the objects. Setpoint flashing and spontaneous
flashing plus the display of various device and communication states (e.g. up-to-
date/not up-to-date, bay blocking and telecontrol blocking ...) are supported with the
aim to provide reliable visualization. Measured values and switchgear states, which
are no longer updated due to a device or communication failure or an active bay
blocking, can be updated manually from the SICAM SCC operator station. The
switchgear devices can be controlled either directly or using "Select before operate".
Topological coloring is available for visualizing the process with single-line diagrams.
Detail
6. SIMATIC WinCC – the platform on which SICAM SCC operates
Important characteristics – overview
The WinCC basic software is the core of an integrated system comprising WinCC,
WinCC options and WinCC Add-ons, all designed to build up a solution tailored to
your specific requirements.
The basic software itself represents a powerful, universally applicable process
visualization system that offers all features of a sophisticated HMI Software:
Runtime Software
All HMI functions onboard, this characterizes the Runtime component of the WinCC
basic software. Starting with a user
administration that meets all requirements of Good Manufacturing Practice (GMP),
ranging to a user interface with lots of configurable controls and functions up to a
performant message and archiving system based on the integrated MS SQL Server.
Reporting and logging system as well as integrated control technology functions
complete the list.
Features
7. SIMATIC WinCC – detailed description of the major functions
Basic functionality
The runtime application of the WinCC basic software
Overview
Integrated User Management
User Interface
Message system
Archiving system
Reporting and Logging System
Control technology functions (Basic Process Control)
Engineering Software
The Engineering Component WinCC CS offers a set of editors that leave nothing to
be desired when talking about efficiency or user friendliness. Libraries and wizards
make the generation of a project fast and easy and reduce error-proneness
considerably. As a software for most complex HMI tasks, WinCC is able to handle
comprehensive projects and mass data.
Features
8. Scalability with WinCC
From single-user system to web-based solution
Overview
Client-Server solutions
Central Archive Server Solutions
Redundant Server Solutions
Web-Client Solutions
Thin-Client Solutions
Virtualization
In addition to WinCC Clients, WinCC Servers can now also be used with WinCC V7.0
SP3 under VMware ESXi, and engineering stations under VMware Workstation or
VMware Player. This means that complex client/server structures as well as single-user
systems can be configured with virtual environments.
Virtualization with SIMATIC WinCC
Cost-effective, resilient and flexible IT infrastructures
Overview
Description
Benefits
Hardware and software requirements
Features
9. Mob No:
Mr. Piyush Rathi- +91-9819614841
Website:
www.reliservsolution.com
Email-ID:
piyush@reliserv.in
sales1@reliserv.in
Address:
Office No: 9, Space Heights,
Plot No. 53/54 , Sector 34,
Kamothe,Navi Mumbai- 410209
Contact Us