2. HOUSES, BUNGALOWS & FLATS FOR LIVING.
HOSPITALS & HEALTH CENTRES FOR HEALTH.
SCHOOL, COLLEGES & UNIVERSITIES FOR
EDUCATION.
BANKS, SHOPS, OFFICES, BUILDINGS FOR
DOING WORK.
RAILWAY BUILDINGS, BUS STATIONS & AIR
TERMINALS FOR TRANSPORTATION.
CLUBS, THEATRES & CINEMA HOUSES FOR
RECREATION.
TEMPLES, MOSQUES, CHURCHES FOR
WORSHIP.
3. CLIMATES & ITS EFFECT.
PEOPLE & THEIR REQUIREMENT.
MATERIALS FOR CONSTRUCTION.
REGULATIONS & BYE- LAWS OF SANCTIONING
AUTHORITIES.
4. GROUP A- RESIDENTIAL BUILDINGS.
GROUP B- EDUCATIONAL BUILDINGS.
GROUP C- INSTITUTIONAL BUILDINGS.
GROUP D- ASSEMBLY BUILDINGS.
GROUP E- BUSINESS BUILDINGS.
GROUP F- MERCENTILE BUILDINGS.
GROUP G- INDUSTRIAL BUILDINGS.
GROUP H- STORAGE BUILDINGS.
GROUP J- HAZARDOUS BUILDINGS.
5. BUILDING WITH SLEEPING ACCOMMODATION
WITH OR WITHOUT COOKING OR DINING
FACILITIES.
6. A-1 :- LODGING & ROOMING HOUSES.
A-2 :- ONE OR TWO FAMILY PRIVATE
DWELLING.
A-3 :- DORMITORIES.
A-4 :- APPARTMENT HOUSES. (FLATS)
A-5 :- HOTELS.
7. BUILDING WITH SEPARATE SLEEPING
ACCOMMODATION FOR NOT MORE THAN 15
PERSONS(TEMPORARY OR PERMANENT BASIS)
WITH OR WITHOUT DINING FACILITIES BUT
WITHOUT COOKING FACILITIES FOR
INDIVIDUAL FACILITIES.
8. PRIVATE DWELLING WHICH IS OCCUPIED BY MEMBERS OF A SINGLE
FAMILY.
SLEEPING ACCOMODATION FOR NOT MORE THAN 20 PERSONS.
IF ROOMS ARE RENTED TO OUTSIDERS, THESE SHOULD BE FOR
ACCOMMODATING NOT MORE THAN 3 PERSONS.
9. BUILDING IN WHICH GROUP SLEEPING ACCOMODATION
IS PROVIDED WITH OR WITHOUT DINING FACILITIES
FOR PERSONS WHO ARE NOT MEMBERS OF SAME
FAMILY, IN ANY ONE ROOM OR A SERIES OF CLOSELY
ASSOCIATED ROOMS UNDER SINGLE MANAGEMENT. FOR
EXAMPLE- SCHOOL & COLLEGE DORMITORIES,
STUDENTS & OTHER HOSTELS.
10.
11.
12. SITE SHOULD PREFERABLY BE SITUATED ON AN
ELEVATED AND LEVELLED GROUND.
IT SHOULD NOT BE LOCATED IN A FLOOD
PRONE AREA.
THE SOIL AT SITE SHOULD HAVE GOOD VALUE
OF BEARING CAPACITY.
THE SITE SHOULD NOT BE IRREGULAR IN
SHAPE.THE SITE SHOULD BE RECTANGULAR
OR SQUARE IN SHAPE.
THE SITE SHOULD BE LOCATED IN DEVELOPED
AREA.
13. THE SITE SHOULD BE LOCATED AWAY FROM
QUARRIES, KILN, INDUSTRIAL PLANTS ETC.
THE SITE SHOULD HAVE UNOBSTRUCTED
NATURAL LIGHT AND AIR.
14. THE VARIOUS ASPECTS OF BUILDING ACTIVITIES
COVERED BY BYE-LAWS ARE UNDER:
DISTANCE FROM ELECTRIC LINES
SET BACKS IN A PLOT.
BUILT UP AREA LIMITATIONS.
NORMS RELATED TO HEIGHT OR SIZES OF
ROOMS.
LIGHTING & VENTILATION OF ROOMS.
BUILDING SERVICES.
15.
16. HABITABLE ROOMS- 2.75 M.
KITCHEN- 2.75 M.
BATH ROOMS- 2.4 M.
WC – 2.4 M.
PLINTH LEVEL- 30 CM.
17. HABITABLE ROOMS-
MIN WIDTH:- 2.4 M.
MIN AREA :- 9.5 SQ.M
DRAWING ROOM-
MIN WIDTH:- 3 M.
MIN AREA :- 11 SQ.M
STUDY ROOM -
MIN WIDTH:- 2.4 M.
MIN AREA :- 9.5 SQ.M
18. KITCHEN WITH STORE-
MIN WIDTH:- 1.5 M.
MIN AREA :- 5.6 SQ.M
KITCHEN HAVING SEPARATE STORE-
MIN WIDTH:-
MIN AREA :- 4.5 SQ.M
KITCHEN WITH DINING ROOM-
MIN WIDTH:- 2.4 M.
MIN AREA :- 9.5 SQ.M
19. BATH ROOM -
MIN WIDTH:- 1.5 M X 1.2M
MIN AREA :- 1.8 SQ.M
COMBINED BATHROOM & WC-
MIN WIDTH:- 1.2M
MIN AREA :- 1.8 SQ.M
WC-
MIN WIDTH:-
MIN AREA :- 1.1 SQ.M
20. 1/10th OF FLOOR AREA IN DRY HOT CLIMATE.
1/6TH OF FLOOR AREA IN WET HOT CLIMATE.
AREA OF DOORS & WINDOWS IN A ROOM IS
NOT LESS THAN 1/7TH OF FLOOR AREA.
21. BUILTUP AREA OR COVERED AREA OF A BUILDING ON GROUND-
PLOT AREA- AREA OF OPEN SPACES AROUND THE BUILDING.
F.A.R (FLOOR AREA RATIO):-
F.A.R = COVERED AREA OF ALL FLOORS
PLOT AREA
22.
23.
24. Water Supply Requirements for Buildings
Water Supply for Residences:-
a) A minimum of 70 to 100 litres per head per
day for domestic needs of urban communities.
b) For communities with population upto 20000
and without flushing system:
1) water supply through = 40 lphd, Min standpost.
2) water supply through = 70 to 100 lphd house.
service connection
25. c) For communities with population 20000 to100000
together with full flushing system.
= 100 to 150 lphd.
d) For communities with population above 100000
together with full flushing system.
= 150 to 200 lphd.
Out of the 150 to 200 litres per head per day,
45 litres per head per day may be taken for flushing
requirements and the remaining quantity for other
domestic purposes.