1. Gill E730D Wind Gauge Wiring to Display
The wind gauge has two DB9 Female connectors. One connector is labeled REMOTE and the other connector is labeled
INPUT/OUTPUT. Use the connector labeled REMOTE to connect the Alzatex, inc. display.
Set the baud rate on the display to 9,600 (Mode B3)
DB9-M to DB9-M cable.
Alzatex Display without built in battery and charger has a DB9-Female connector.
DB9-Male From Wind Gauge DB9-Male To Display
Remote
DB9-F to DB9-M cable.
Alzatex Display with built in battery and charger has a DB9-Male connector.
DB9-Male From Wind Gauge DB9-Female To Display
Alzatex, Inc Remote
6400 SW 213th Ave
Aloha, OR 97007
www.alzatex.com
terryl@alzatex.com
NOTE: You must use the custom cable provided by
503 642-9693 Alzatex. A standard serial cable will not work.
Designed by Terry Lang
1-Feb-2009