DC117A interconnection diagram
                                                 TM
    Single Data Channel Timekeeper RX42...
DC117A Remote Button Wiring

                                                                                          To ...
Upcoming SlideShare
Loading in …5
×

Dc117a Wiring0

225 views

Published on

Published in: Business, Sports
0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total views
225
On SlideShare
0
From Embeds
0
Number of Embeds
3
Actions
Shares
0
Downloads
1
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

Dc117a Wiring0

  1. 1. DC117A interconnection diagram TM Single Data Channel Timekeeper RX422 Input or TX422 Output For single data channel communication on a cat-5 cable (Pair 2 used for power). RJ-45 Ground TimekeeperTM (1) WH/OR + Power (2) OR/WH Ground (3) WH/GN Data P 8 cond (4) BL/WH Data N (5) WH/BL Cat-5 + Power (6) GN/WH Ground (7) WH/BN + Power (8) BN/WH Products that have a 2x6 pin jumper block TM Single Data Channel Timekeeper RX422 Input or TX422 Output For single data channel communication on a cat-5 cable (Pair 2 not used). RJ-45 Ground TimekeeperTM (1) WH/OR + Power (2) OR/WH (Not used) --------- (3) WH/GN Data P 8 cond (4) BL/WH Data N (5) WH/BL Cat-5 (Not used) --------- (6) GN/WH Ground (7) WH/BN + Power (8) BN/WH Products that have a 2x6 pin jumper block TM Dual Data Channel Timekeeper RX422 Input and TX422 Output For bi-directional data communication on a single cat-5 cable (Pair 2 used for data). RJ-45 Ground TimekeeperTM (1) WH/OR + Power (2) OR/WH Data 2N (3) WH/GN Data 1P 8 cond (4) BL/WH Data 1N (5) WH/BL Cat-5 Data 2P (6) GN/WH Ground (7) WH/BN + Power (8) BN/WH Products that have a 2x6 pin jumper block Alzatex, Inc. Www.alzatex.com 09-14-2009
  2. 2. DC117A Remote Button Wiring To REM jack on DC117A-PROD1 Run Pause Stopped Next RJ-11 Jack 6 cond modular crossover cord Red Pause Setup or Changeover time White Run Production running Yellow Stopped For lunch breaks, etc. 3-RD 1-WH 5-YL (6) Up (5) Reset RJ-11 (4) Ground (3) Stop/Dn Jack (2) +V (1) Start 6 cond modular crossover cord 4-GN 6-BL 2-BK Black +Voltage +Voltage Blue Next Increment the actual count Green Ground Ground TM Timekeeper Remote Ground Closure Input wiring (Crossover Phone Cord) RJ-11 Run Data 3 TimekeeperTM (1) WH +12V +12V (2) BK 6 cond Pause Data 1 (3) RD Ground ground Crossover (4) GN Stopped Data 2 (5) YL Next Data 4 (6) BL TM Timekeeper Remote Ground Closure Input wiring (Standard Phone Cord) RJ-11 Next Data 4 TimekeeperTM (1) WH Stopped Data 2 (2) BK Ground Ground 6 cond (3) RD Pause Data 1 (4) GN Standard +12V +12V (5) YL Run Data 3 (6) BL Alzatex, Inc. Www.alzatex.com 09-14-2009

×