1. ®
VENTURE LIGHTING
E N E R G Y S AV I N G
LIGHTING
SOLUTIONS
M E TA L H A L I D E T E C H N O L O G Y U P G R A D E
2. Energy Saving Solutions
R EPLACE
Lumen Maintenance Comparison
100,000 875W
1000 Watt
Pulse Start
Probe Start
Lamp Lumens
80,000
60,000 Standard
Probe Start
With Venture’s 875W Pulse Start System 40,000
1000W
400W
(Rated Lamp Life
10,000 Hours)
Case Study Benefits:
12,000
5,000 10,000 15,000 20,000
20,000
Hours of Operation
A 1.3 million square foot steel mill located near Gary, • Twice the light
Indiana was utilizing (1190) 1000-watt standard probe • Annual savings of over $400,000
start metal halide, (340) 1000-watt mercury vapor and
• Reduction of energy usage by 50%
(170) 400-watt high pressure sodium high bay lights.
Choosing Venture Lighting’s superior 875-watt pulse start
system, they were able to reduce the fixture count by
44%, resulting in 50% energy savings. Overall, (952)
875-watt pulse start metal halide systems replaced the
original (1700) systems, reducing inventory and lighting
maintenance costs.
Comparisons
Venture’s 875 Watt Previous
Pulse Start vs Systems
952 Number of Fixtures 1700
20,000+ Lamp Life Hours 12,000
50 Average footcandles 14
7.3 Million kWh Energy Consumption 0
Reduction for Lighting
50% Energy Savings 0
$400,000 Total Annual Savings 0
for one facility
With Venture’s 775W Natural White ®
Case Study
Classic Toyota, located in Northeast Ohio, replaced (121)
1000-watt standard probe start lamps and ballasts in Benefits:
their car lot with 775-watt Natural White lamps and • Lamp lumen depreciation
ballasts. This resulted in a huge decrease in energy of 0.90
consumption of over 22%. The lot draws attention to the
• High CRI lighting, 90+
dealership due to the brighter and “whiter” lighting.
with daylight color: 5000K CCT
Comparisons • Excellent color uniformity
Venture’s 775 Watt Previous
Pulse Start vs Systems
121 Number of Fixtures 121
20,000+ Lamp Life Hours 12,000
22 Average footcandles 13
142,175 kWh Energy Consumption 0
Reduction for Lighting
22% Energy Savings 0
$22,374 Total Annual Savings 0
for one facility
3. R EPLACE
Lumen Maintenance Comparison
45,000
40,000
400 Watt
Uni-Form®
320W
Probe Start
Lamp Lumens
35,000
30,000
25,000
20,000
Standard
Probe Start
400W With Venture’s 320W Pulse Start System
15,000
5,000 10,000
Hours of Operation
15,000 20,000
Case Study Comparisons
Western Pennsylvania’s Montour School District had a Venture’s 320 Watt Previous
requirement to reduce costs by 16% at their five Uni-Form® Pulse Start vs Systems
123 Number of Fixtures 123
gymnasiums (totaling 37,000 square feet). They chose to
349 System Watts per Fixture 455
replace the combination of 400-watt probe start metal
60-64 Average footcandles 40-45
halide and mercury vapor systems with Venture Lighting’s
25% Energy Savings 0
320-watt Uni-Form® pulse start systems and exceeded this (additional 50% by
requirement. Over a 10-year span, savings will using bi-level dimming)
exceed $1 million. $100,100 Total Annual Savings 0
Benefits:
• Saved 25% energy by switching to 320W pulse start
• Saved an additional 50% by using bi-level dimming
• 1.5 times the illuminance level
R EPLACE
Probe Start 250 Watt
Lumen Maintenance Comparison
22,000
With Venture’s 200W
Uni-Form®
18,000
200W
320W Pulse Start System
Lamp Lumens
14,000 Standard
Probe Start
250W
400W Standard
Probe Start
10,000 175W
400W
(Rated Lamp Life
10,000 Hours)
6,000
5,000 10,000 15,000
Comparisons
Hours of Operation Venture’s 200 Watt Previous 250 Watt
Pulse Start vs Probe Start Systems
91 Number of Fixtures 91
Case Study 15,000 Lamp Life Hours 10,000
SuperMall of The Great Northwest, in Auburn, WA is a 96 Lumens per System Watt 72
one-million-square-foot-plus shopping complex serving 235 System Watts 290
over 7,000,000 customers annually. Owned by Glimcher $1,822 Total Annual Savings 0
Realty Trust, they were in the process of updating lighting (food court only)
in all areas. Paul Hensley, operations director of the mall, Benefits:
was looking for “more uniform brighter light, with energy • Brighter, better quality lighting
savings”. In the food court areas of the mall, (91) 250-
• Energy savings
watt standard probe start lamps and ballasts were
replaced with the same number of Venture’s 200-watt • Energy utility rebates, reducing pay-back period
Uni-Form pulse start systems. • Excellent color uniformity
3