The
   21st Century
 Green New Light




ELECTRODELESS LAMP EDL
Benefits of Induction Lighting
•   Long Life - 100,000 hours
•   Color rendering - 85 CRI
•   Color Temperature - 2,700K-6...
Ultra-long service life




The aging of lamp filament and electrode sputter are the main factors
          that limit the...
High-efficiency and energy-saving




The lighting efficiency of the system reaches up to 65lm/w, the power factor
      r...
Green and environmental-protection




      Solid amalgam and lead-free glass are used.
  Over 99% of materials can be re...
Excellent color rendering




The color rendering index is larger than 80. And the light color is mild,
             which...
Optional color temperature




The color temperature ranges from 2700°K-6500°K.
  And there are also many colorful light b...
Little light evanescence




The luminous flux maintenance factor for 2,000 hours is 95%.
The luminous flux maintenance fa...
No strobe




   It works in 2.65MHz frequency, which will not produce
the harm of stroboscopic effect and, therefore, pro...
Instant-on and restart




              It lights instantly.
And the switching number reaches up to 200,000.
Large range of working temperature




The amalgam technology is adopted and it needs no further warm-up.
     It can star...
Shake-proof and explosion-proof




The shake resistance performance is excellent and the lighting location
    can be any...
Induction Lamps vs. H.I.D. Lamps
Comparison                  Induction                                     Metal Halide   ...
Induction Lamps vs. Fluorescent Lamps
Comparison                  Induction                                      Compact F...
Case Study in Induction Lighting
Comparison Item       Old Lighting System                           New Lighting System
L...
Technical Data
Technology                               Wattage   Fixture   Life       CRI         Mean
                Me...
Operation Costs Estimated
Technology                                   Wattage       Lamp         Energy         Maint-   ...
The 21st Century Green New Light



               ELECTRODELESS LAMP EDL


        For Sales:          For Investment Opp...
Upcoming SlideShare
Loading in …5
×

Ecoluminous induction lamp

1,112 views

Published on

www.xinghenglong.com

Published in: Technology
2 Comments
1 Like
Statistics
Notes
  • We, Oppeo Lighting, affilated to Yuan Investment Group, one professional manufacturer and supplier of induction lamp and LED light, we have been involved in the R&D, manufacturing and marketing in this field since 2003. In the inception, we have cooperated with photoelectric institute from Netherland, Japan and others. Accumulated fruitful experience with approx 7 years with our competent partners, we have supplied and serviced to our esteemed customers with high added value products. Depending on successful experience and aim at the big potential worldwide, we also will take our best to expand business to worldwide market.

    Our product series as below:
    Induction Lighting: Luminarie, Ballast, High bay light, Street light, Tunnel light, Flood light, Ceiling light as well
    LED Lighting: Daylight, Spotlight, Bulb light, Cabinet light as well

    Welcome to visit www.oppeo.com or email oppeolighting@gmail.com
       Reply 
    Are you sure you want to  Yes  No
    Your message goes here
  • Our Led Down light is good in quality and competitive in price. We are manufacturer and supplier of Led Down light. We export Led Down light . We supply OEM service of Led Downlight for you. We would manufacture Led Down light following your specific requirement. We are looking forward to your E-mail and establishing cooperative relationship with you! We would provide professional Led Downlight with good services for you!Welcome to www.aoneled.com
       Reply 
    Are you sure you want to  Yes  No
    Your message goes here
No Downloads
Views
Total views
1,112
On SlideShare
0
From Embeds
0
Number of Embeds
2
Actions
Shares
0
Downloads
42
Comments
2
Likes
1
Embeds 0
No embeds

No notes for slide

Ecoluminous induction lamp

  1. 1. The 21st Century Green New Light ELECTRODELESS LAMP EDL
  2. 2. Benefits of Induction Lighting • Long Life - 100,000 hours • Color rendering - 85 CRI • Color Temperature - 2,700K-6,500K • Energy Efficient - 85+ Lumens per Watt • Lumen maintenance - 70% of its light output at 100,000 hrs • Maintenance costs - go 10 years without a change out • Instant on Capability - Can be used with photocell or motion sensor • High Output - 70W to 400W • No flickering, No Strobing, No Noise • Minimal Color shifting • Starting temperatures as low as -40 degrees Fahrenheit
  3. 3. Ultra-long service life The aging of lamp filament and electrode sputter are the main factors that limit the service life of traditional light sources. The Electrodeless Lamp has no lamp filament and electrode inside, and uses high frequency electromagnetic induction coupling to produce light. The working life is above 50,000 hours.
  4. 4. High-efficiency and energy-saving The lighting efficiency of the system reaches up to 65lm/w, the power factor reaches up to 99%. The energy consumption of idle work is reduced. It saves above 90% energy when compared with incandescent lamp, and saves above 50% energy when compared with high pressure mercury lamp and high pressure sodium lamp.
  5. 5. Green and environmental-protection Solid amalgam and lead-free glass are used. Over 99% of materials can be recycled, which meets the international requirement of environmental protection.
  6. 6. Excellent color rendering The color rendering index is larger than 80. And the light color is mild, which can present the natural color of objects.
  7. 7. Optional color temperature The color temperature ranges from 2700°K-6500°K. And there are also many colorful light bulb patterns.
  8. 8. Little light evanescence The luminous flux maintenance factor for 2,000 hours is 95%. The luminous flux maintenance factor for 20,000 hours is 80%. The luminous flux maintenance factor for 60,000 hours is 75%.
  9. 9. No strobe It works in 2.65MHz frequency, which will not produce the harm of stroboscopic effect and, therefore, protect eyesight.
  10. 10. Instant-on and restart It lights instantly. And the switching number reaches up to 200,000.
  11. 11. Large range of working temperature The amalgam technology is adopted and it needs no further warm-up. It can start-up and work normally in temperatures ranging from 40°C to 55°C.
  12. 12. Shake-proof and explosion-proof The shake resistance performance is excellent and the lighting location can be any place because there is no lamp filament and electrode in the light bulb. Moreover, the surface temperature is very low when lighted, which makes it highly explosion-proof.
  13. 13. Induction Lamps vs. H.I.D. Lamps Comparison Induction Metal Halide High Pressure Sodium Warranty Compact: 5 years Separate: 10 years None None Life Hours Compact: 60,000 Separate: 100,000 6,000~20,000 24,000 Energy Saving Efficiency Excellent Lower Lower Lumen Efficacy Photopic Efficacy: 150 Plm/W Photopic Efficacy: 110 Plm/W Photopic Efficacy: 90 Plm/W (Plm: Pupil Lumen) (Plm: Pupil Lumen) (Plm: Pupil Lumen) Traditional Efficacy: 80 Lm/W Traditional Efficacy: 75 Lm/W Traditional Efficacy: 120 Lm/W Lumen Depreciation Rate % 5% @ 2,000 Hours 40% @ 2,000 Hours 30% @ 2,000 Hours Lamp Operating Lower < 80° Higher > 300°F Higher > 350°F Temperature Reduces A/C cost Increased A/C cost Increased A/C cost CRI >80 (Ra) 65~80 (Ra) 60 (Ra) Re-strike Instant up to 10~15 minutes up to 10~15 minutes Flicker None Much Much Glare None Much Much Environmental No Mercury Contains mercury Contains mercury Safety No lamp waste in 10 yrs Concern with much Concern with much lamp waste over 10 yrs lamp waste over 10 yrs
  14. 14. Induction Lamps vs. Fluorescent Lamps Comparison Induction Compact Fluorescent Fluorescent Tubes Warranty Compact: 5 years Separate: 10 years None None Life Hours Compact: 60,000 Separate: 100,000 8,000~10,000 8,000~20,000 Energy Saving Efficiency Excellent Good Lower Lumen Efficacy Photopic Efficacy: 150 Plm/W Photopic Efficacy: 85 Plm/W Photopic Efficacy: 69 Plm/W (Plm: Pupil Lumen) (Plm: Pupil Lumen) (Plm: Pupil Lumen) Traditional Efficacy: 80 Lm/W Traditional Efficacy: 50 Lm/W Traditional Efficacy: 70 Lm/W Lumen Depreciation Rate % 5% @ 2,000 Hours 30% @ 2,000 Hours 25% @ 2,000 Hours Lamp Operating Lower < 80° Higher > 100°F Higher > 150°F Temperature Reduces A/C cost Increased A/C cost Increased A/C cost CRI >80 (Ra) 65~80 (Ra) 60 (Ra) Re-strike Instant Instant, with initial Instant, with initial 3 min warm up time 3 min warm up time Flicker None Much Much Glare None Much Much Environmental No Mercury Contains mercury Contains mercury Safety No lamp waste in 10 yrs Concern with much Concern with much lamp waste over 10 yrs lamp waste over 10 yrs
  15. 15. Case Study in Induction Lighting Comparison Item Old Lighting System New Lighting System Light Source Metal Halide High Bay Induction High Bay Wattage 400W ( per lamp ) 200W ( per lamp ) Actual Power Consumption 460W ( lamp & ballast ) 210W ( lamp & ballast ) Brightness 373 Lux 510 Lux Luminous Efficacy Low Efficacy, High Efficacy, Severe Luminous Decline, Low Luminous Decline Poor CRI Excellent CRI Life Hours 8000 hrs. 100,000 hrs. ( 1 year @ 24hrs/Day ) (10 years @ 24hrs/Day) ( Change 274 Bulbs Every Year ) ( Change ZERO Bulbs for 10 Years ) No. of Fixtures 274 Sets 274 Sets Energy and Related Cost Savings: ( 460W vs. 210W ) * 274 Fixtures = 68,500Watts 68,500 Watts * 24 hours/Day / 1000 = 1,644 kWh per Day Savings 1,644kWh/Day * 365 Days per year = 600,000kWh per Year 600,000kWh per Year * .08 rate = $ 48,000/Year Energy Cost Savings Plus: 274 Lamps * $ 21.00ea. = $ 5,754/Year in Replacement Bulbs Costs Plus: Labor to change Bulbs $ 2,500/Year TOTAL Savings per year: $ 56,254 10 Years TOTAL Cost Savings $ 562,540
  16. 16. Technical Data Technology Wattage Fixture Life CRI Mean Mean Pupil High Pressure Sodium 70 Wattage 88 24,000 21 Lumens 5,670 Lumens 3,232 High Pressure Sodium 150 188 24,000 21 14,000 7,980 HighPressure Sodium High Pressure Sodium 250 300 24,000 21 25,600 14,592 High Pressure Sodium 400 464 24,000 21 45,000 25,650 High Pressure Sodium 1000 1,100 24,000 21 126,000 71,820 Induction Lighting 40 41 100,000 80 3,400 5,508 Induction Lighting 80 82 100,000 80 6,800 11,016 Induction Lighting Induction Lighting 100 102 100,000 80 8,500 13,770 Induction Lighting 120 122 100,000 80 10,200 16,524 Induction Lighting 200 204 100,000 80 17,000 27,540 Metal Halide (V) 150 188 15,000 65 11,300 Metal Halide (V) 16,837 175 215 10,000 65 10,000 MetalHalide (V)(V) Metal Halide 14,900 250 295 10,000 65 17,000 Metal Halide (V) 25,330 400 456 10,000 65 28,800 Metal Halide (V) 42,912 1,000 1,070 12,000 65 92,900 Metal Halide (H)138,421 150 188 11,250 65 10,170 Metal Halide (H)15,153 175 215 7,500 65 9,000 MetalHalide (H)13,410 Metal Halide (H) 250 295 7,500 65 15,300 Metal Halide (H)22,797 400 456 7,500 65 25,920 Metal Halide (H)38,621 1,000 1,070 9,000 65 92,900 138,421 High Pressure Sodium 180 220 16,000 0 26,100 9,918 High Pressure Sodium 135 178 16,000 0 19,140 7,273 Low Pressure Sodium High Pressure Sodium 90 124 16,000 0 11,095 4,216 High Pressure Sodium 55 80 18,000 0 6,655 2,529 High Pressure Sodium 35 60 18,000 0 4,000 1,520
  17. 17. Operation Costs Estimated Technology Wattage Lamp Energy Maint- Material Cost of Changes In 10 Yrs enance In 10 Yrs Operation in High Pressure Sodium 70 In 10 Yrs 3.7 927 In 10 Yrs 201 73 In 10 Yrs 1,201 High Pressure Sodium 150 3.7 1,971 201 73 2,245 HighPressure Sodium High Pressure Sodium 250 3.7 3,154 201 73 3,427 High Pressure Sodium 400 3.7 4,878 201 73 5,151 High Pressure Sodium 1000 3.7 11,563 201 224 11,988 Induction Lighting 40 0 429 0 0 429 Induction Lighting 80 0 858 0 0 858 Induction Lighting Induction Lighting 100 0 1,072 0 0 1,072 Induction Lighting 120 0 1,287 0 0 1,287 Induction Lighting 200 0 2,144 0 0 2,144 Metal Halide (V) 150 5.8 1,971 321 187 Metal Halide (V) 2,479 175 8.8 2,263 482 278 MetalHalide (V)(V) Metal Halide 3,022 250 8.8 3,101 482 280 Metal Halide (V) 3,863 400 8.8 4,793 482 280 Metal Halide (V) 5,556 1,000 7.3 11,248 402 365 Metal Halide (H)12,014 150 7.8 1,971 428 249 Metal Halide (H)2,648 175 11.7 2,263 642 370 MetalHalide (H)3,275 Metal Halide (H) 250 11.7 3,101 642 374 Metal Halide (H)4,117 400 11.7 4,793 642 374 Metal Halide (H)5,810 1,000 9.7 11,248 535 487 12,270 High Pressure Sodium 180 5.5 2,308 301 345 2,954 High Pressure Sodium 135 5.5 1,873 301 257 2,432 Low Pressure Sodium High Pressure Sodium 90 5.5 1,306 301 203 1,809 High Pressure Sodium 55 4.9 838 268 161 1,267 High Pressure Sodium 35 4.9 629 268 161 1,057 Based on: • 24 / 7 Operations • 0.12 kilowatt / Hour • $55 / Hour labor charge
  18. 18. The 21st Century Green New Light ELECTRODELESS LAMP EDL For Sales: For Investment Opportunity: Contact Contact Frank Fu: (510) 648-5959 John Luk: or (408) 858-1888 Joseph Yu: (925) 226-1606 johnl@GDcommercial.com

×