SlideShare a Scribd company logo
1 of 30
Download to read offline
1
Catalyst 2960-S Switch Getting Started Guide
OL-19793-02
Catalyst 2960-S Switch
Getting Started Guide
• About This Guide
• Unpacking the Switch
• Running Express Setup
• Managing the Switch
• Planning and Creating Switch Stacks
• Rack-Mounting
• Connecting the FlexStack Cables
• Connecting to the Switch Ports
• In Case of Difficulty
• Obtaining Documentation and Submitting a Service Request
Catalyst 2960-S Switch Getting Started Guide
2
Catalyst 2960-S Switch Getting Started Guide
OL-19793-02
About This Guide
This guide provides instructions on how to use Express Setup to initially
configure your Catalyst switch. It also covers switch management options, basic
rack-mounting, stacking guidelines, port and module connection procedures, and
troubleshooting help.
For additional installation and configuration information for the switch, see the
Catalyst 2960 documentation on Cisco.com. For system requirements, important
notes, limitations, open and resolved bugs, and last-minute documentation
updates, see the release notes, also on Cisco.com. For translations of the warnings
that appear in this publication, see the Regulatory Compliance and Safety
Information for the Catalyst 2960 and 2960-S Switches on Cisco.com.
When using the online publications, see the documents that match the Cisco IOS
software version running on the switch. The software version is on the Cisco IOS
label on the switch rear panel.
Unpacking the Switch
Follow these steps:
1. Unpack and remove the switch and the accessory kit from the shipping box.
2. Return the packing material to the shipping container, and save it for future
use.
3. Verify that you have received these items. If any item is missing or damaged,
contact your Cisco representative or reseller for instructions.
3
Catalyst 2960-S Switch Getting Started Guide
OL-19793-02
Catalyst 2960-S Switch Getting Started Guide
1 Catalyst 2960-S switch1
1. Catalyst 2960S-48FPD-L switch shown for example. Your switch model might look different.
9 Four number-8 Phillips truss-head screws
(48-0656-01)
2 AC power cord 10 Four number-8 Phillips flat-head screws
(48-0655-01)
3 Four rubber mounting feet 11 Two number-4 pan-head screws (48-0482-01)
4 Documentation 12 One black Phillips machine screw (48-0654-01)
5 Two 19-inch mounting brackets 13 (Optional3
) Console cable or USB cable
6 Connector2
cover for redundant power
system
2. Only available on some models.
14 (Optional3
) Cisco FlexStack module
7 Cable guide 15 (Optional3
) Cisco FlexStack cable
8 Four number-12 Phillips pan-head screws
(48-0523-01)
16 (Optional3
) Power cord retainer
3. Item is orderable.
C
atalyst2960-S
S
w
itch
D
ocum
entation
Catalyst 2960-S Series
PoE+ 10G
11X
2X
1X
11X
14X12X
13X
23X
24X
25X
26X
37X 39X
36X 38X
47X
48X
1
2
POWER
OVER
ETHERN
ET 740W
8
9
10
4
5
6
11
13
2
7
12
1
3
14 15 16
206224
Catalyst 2960-S Switch Getting Started Guide
4
Catalyst 2960-S Switch Getting Started Guide
OL-19793-02
Running Express Setup
When you first set up the switch, you should use Express Setup to enter the initial
IP information. Doing this enables the switch to connect to local routers and the
network. You can then access the switch through the IP address for further
configuration.
You need this equipment to set up the switch:
• A PC with Windows 2000, XP, Vista, or Windows Server 2003 installed
• A web browser (Internet Explorer 6.0, 7.0, Firefox 1.5, 2.0, or later) with
JavaScript enabled
Note Other laptops and browsers might work.
• A straight-through or crossover Category 5 or 6 Ethernet cable to connect
your PC to the switch
Note Before running Express Setup, disable any pop-up blockers or proxy settings in
your browser software and any wireless client running on your PC.
Step 1 Make sure that nothing is connected to the
switch.
Step 2 During Express Setup, the switch acts as a DHCP server. If your PC has a static IP address,
temporarily configure your PC settings to use DHCP before proceeding to the next step.
Note Write down the static IP address. You will need this IP address in Step 10.
Cataly
st 2960-S
Series
PoE+ 10G
11X
2X
1X
11X
14X12X
13X
23X
24X
25X
26X
37X 39X
36X 38X
47X
48X
1
2
206225
5
Catalyst 2960-S Switch Getting Started Guide
OL-19793-02
Catalyst 2960-S Switch Getting Started Guide
Step 3 Power the switch by connecting the AC power
cord to the switch power supply and to a
grounded AC outlet.
Approximately 30 seconds after the switch
powers on, it begins the power-on self-test
(POST), which can take several minutes to
complete.
During POST, the SYSTEM LED blinks
green, and the RPS, STATUS, DUPLEX, and
SPEED LEDs turn solid green.
When POST is complete, the SYSTEM LED
remains solid green, and the other LEDs go
off. The exception is the STACKMASTER
LED, which remains solid green if the switch
is stackable and is acting as stack master.
Before proceeding to the next step, wait until
POST is complete. This might take up
to 5 minutes after the switch is powered on.
Troubleshooting:
If the SYSTEM LED blinks green, does not turn
solid green, or turns amber, contact your Cisco
representative or reseller. The switch failed the
power-on self-test (POST).
RATING
100-240~12-6A, 50-60Hz
206226
Catalyst 2960-S Switch Getting Started Guide
6
Catalyst 2960-S Switch Getting Started Guide
OL-19793-02
Step 4 Press and hold the Mode button until all of the
LEDs above the Mode button turn solid green.
You might need to hold the button for 3 or
more seconds.
Release the Mode button after all of the LEDs
above the Mode button turn solid green. (The
RPS LED remains off on some switch models,
and is not present on all models.)
The switch is now in Express Setup mode.
Before proceeding to the next step, make sure
that all of the LEDs above the Mode button
are solid green.
Troubleshooting:
If the LEDs above the Mode button blink after
you press the button, release it. Blinking
LEDs mean that the switch is already
configured and cannot go into Express Setup
mode. For more information, see the
“Resetting the Switch” section on page 28.
Cataly
st 2960-S
Series
PoE+ 10G
11X
2X
1X
11X
14X12X
13X
23X
24X
25X
26X
37X 39X
36X 38X
47X
48X
1
2
206598
7
Catalyst 2960-S Switch Getting Started Guide
OL-19793-02
Catalyst 2960-S Switch Getting Started Guide
Step 5 Connect a Category 5 or 6 Ethernet cable to
one of these locations:
• Any 10/100 or 10/100/1000 Ethernet
downlink port (such as port 1) on the
switch front panel.
• The Ethernet management port on the
switch front panel.
Connect the other end of the cable to the
Ethernet port on your PC.
Before proceeding to the next step, wait until
the port LEDs on the switch and your PC or
laptop are green (either solid or blinking).
The green port LEDs indicate a successful
connection.
Troubleshooting:
If the port LEDs do not turn green after about
30 seconds, make sure that:
• You connected the Ethernet cable to one
of the downlink switch ports (not to an
uplink port such as the dual-purpose
port).
• You are using an undamaged Category 5
or 6 Ethernet cable.
• The other device is turned on.
Catalys
t 2960XS
Series
PoE 10G
11X
2X
1X
11X
14X12X
13X
23X
24X
25X
26X
37X 39X
36X 38X
47X
48X
1
2
206228
Catalyst 2960-S Switch Getting Started Guide
8
Catalyst 2960-S Switch Getting Started Guide
OL-19793-02
Step 6 Enter the IP address 10.0.0.1 in a web browser
and press Enter.
When prompted, enter the default password,
cisco.
Note The switch ignores text in the
username field.
The Express Setup window appears.
Troubleshooting:
If the Express Setup window does not appear,
make sure that any pop-up blockers or proxy
settings on your browser are disabled and that
any wireless client is disabled on your PC or
laptop.
9
Catalyst 2960-S Switch Getting Started Guide
OL-19793-02
Catalyst 2960-S Switch Getting Started Guide
Step 7 Enter the required settings in the Express Setup window.
Note All entries must be in English letters and numbers.
Required Fields
Enter this information in the Network Settings fields:
• In the Management Interface (VLAN ID) field, the default is 1.
Note We recommend using the default VLAN value because during Express Setup, VLAN
1 is the only VLAN on the switch.
Enter a new VLAN ID only if you want to change the management interface through
which you manage the switch. The VLAN ID range is 1 to 1001.
• In the IP Address field, enter the IP address of the switch.
• In the Subnet Mask field, click the drop-down arrow, and select a subnet mask.
• In the Default Gateway field, enter the IP address for the default gateway (router).
• Enter your password in the Switch Password field. The password can be from 1 to 25
alphanumeric characters, can start with a number, is case sensitive, allows embedded
spaces, but does not allow spaces at the beginning or end. In the Confirm Switch
Password field, enter your password again.
Note You must change the password from the default password, cisco.
Optional Fields
You can enter other administrative settings in the Express Setup window. For example, the
optional administrative settings identify and synchronize the switch for enhanced
management. The switch clock is automatically synchronized with the network clock by using
NTP. You can manually set the system clock settings if the switch should have different time
settings.
Click Submit to save your changes and to complete the initial setup.
For more information about the Express Setup fields, see the online help for the Express Setup
window.
Step 8 After you click Submit, these events occur:
• The switch is configured and exits Express Setup mode.
• The browser displays a warning message and tries to connect with the earlier switch IP
address. Typically, connectivity between the PC and the switch is lost because the
configured switch IP address is in a different subnet from the IP address on the PC.
Catalyst 2960-S Switch Getting Started Guide
10
Catalyst 2960-S Switch Getting Started Guide
OL-19793-02
Step 9 Disconnect the switch from the PC, and install the switch in your network. See the
“Rack-Mounting” section on page 18.
Step 10 If you changed the static IP address on your PC in Step 2, change it back to the previously
configured static IP address.
Step 11 You can now manage the switch by using Cisco Network Assistant, Device Manager, or both.
See the “Managing the Switch” section on page 11 for information about configuring and
managing the switch.
We strongly recommend that you download Cisco Network Assistant from Cisco.com and use
it to manage the switch. See the “Managing the Switch” section on page 11 for information
about configuring and managing the switch.
You can display Device Manager by following these steps:
1. Start a web browser on your PC or laptop.
2. Enter the switch IP address, username, and password (assigned in Step 7) in the web
browser, and press Enter. The Device Manager page appears.
Troubleshooting:
If Device Manager does not appear:
• Confirm that the port LED for the switch port connected to your network is green.
• Confirm that the PC or laptop you are using to access the switch has network connectivity
by connecting to a well-known web server in your network. If there is no network
connection, troubleshoot the network settings on the PC or laptop.
• Make sure that the switch IP address in the browser is correct.
• If switch IP address in the browser is correct, the switch interface LED is green, and the
PC or laptop has network connectivity, continue troubleshooting by reconnecting the PC
or laptop to the switch. Configure a static IP address on the PC or laptop that is in the
same subnet as the switch IP address. For example:
– If your switch IP address is 172.20.20.85 and your PC or laptop IP address is
172.20.20.84, both devices are in the same network.
– If your switch IP address is 172.20.20.85 and your PC or laptop IP address is
10.0.0.2, the devices are in different networks and cannot communicate directly.
• When the LED on the switch port connected to the PC or laptop is green, reenter the IP
address of the switch in a web browser to display Device Manager. Once Device Manager
appears, you can continue with the switch configuration.
11
Catalyst 2960-S Switch Getting Started Guide
OL-19793-02
Catalyst 2960-S Switch Getting Started Guide
Managing the Switch
After completing Express Setup and installing the switch in your network, you
can use one of these options for further configuration:
• Device Manager
• Cisco Network Assistant
• Command-Line Interface
• Other Management Options
Device Manager
The simplest way to manage the switch is by using Device Manager in the switch
memory. This web interface offers quick configuration and monitoring. You can
access Device Manager from anywhere in your network through a web browser.
1. Launch a web browser on your PC or workstation.
2. Enter the switch IP address in the web browser, and press Enter. The Device
Manager page appears.
3. Use Device Manager to perform basic switch configuration and monitoring.
See the Device Manager online help for more information.
4. For more advanced configuration, download and run Cisco Network
Assistant, which is described in the next section.
Cisco Network Assistant
Cisco Network Assistant is a software program that you download from
Cisco.com and run on your PC. It offers advanced options for configuring and
monitoring multiple devices, including switches, switch clusters, switch stacks,
routers, and access points. Cisco Network Assistant is free—there is no charge to
download, install, or use it.
1. Go to this Web address:
http://www.cisco.com/en/US/products/ps5931/tsd_products_support_series_
home.html.
Catalyst 2960-S Switch Getting Started Guide
12
Catalyst 2960-S Switch Getting Started Guide
OL-19793-02
You must be a registered Cisco.com user, but you need no other access
privileges.
2. Find the Network Assistant installer.
3. Download the Network Assistant installer and run it. (You can run it directly
from the Web if your browser offers this choice.)
4. When you run the installer, follow the displayed instructions. In the final
panel, click Finish to complete the Network Assistant installation.
See the Network Assistant online help and the getting started guide for more
information.
Command-Line Interface
You can enter Cisco IOS commands and parameters through the CLI. Access the
CLI by using one of these options:
• Switch Console Port
• Switch Ethernet Management Port
• Switch USB Port
13
Catalyst 2960-S Switch Getting Started Guide
OL-19793-02
Catalyst 2960-S Switch Getting Started Guide
Switch Console Port
1. Connect the supplied RJ-45-to-DB-9 adapter cable to the standard 9-pin
serial port on the PC. Connect the other end of the cable to the console port
on the switch.
2. Start a terminal-emulation program on the PC.
3. Configure the PC terminal emulation software for 9600 baud, 8 data bits, no
parity, 1 stop bit, and no flow control.
4. Use the CLI to enter commands to configure the switch. See the software
configuration guide and the command reference for more information.
Switch Ethernet Management Port
1. Connect a Category 5 Ethernet cable to the PC Ethernet port. Connect the
other end of the cable to the Ethernet management port on the switch.
2. Start a Telnet session on the PC.
3. Enter the switch IP address that you assigned by using Express Setup.
4. Use the CLI to enter commands to configure the switch. See the software
configuration guide and the command reference for more information.
Switch USB Port
1. Connect an USB cable to the PC USB port. Connect the other end of the cable
to the mini B (5-pin-connector) USB port on the switch.
2. Start a terminal-emulation program on the PC.
3. Configure the PC terminal emulation software for 9600 baud, 8 data bits, no
parity, 1 stop bit, and no flow control.
4. Use the CLI to enter commands to configure the switch. See the software
configuration guide and the command reference for more information.
Note You cannot use the switch console port and the switch USB port at the
same time to access the CLI.
Catalyst 2960-S Switch Getting Started Guide
14
Catalyst 2960-S Switch Getting Started Guide
OL-19793-02
Other Management Options
You can use SNMP management applications such as CiscoWorks LAN
Management Solution (LMS) and Cisco netManager to configure and manage the
switch. You also can manage it from an SNMP-compatible workstation that is
running platforms such as Cisco netManager or SunNet Manager.
The Cisco Configuration Engine is a network management device that works with
embedded Cisco Networking Services (CNS) agents in the switch software. You
can use it to automate initial configurations and configuration updates on the
switch.
See the “Accessing Help Online” section on page 28 for a list of supporting
documentation.
Planning and Creating Switch Stacks
Note This section applies only to the Catalyst 2960-S stacking switches.
Before connecting the switches in a stack, keep in mind these switch stack
guidelines:
• Connect only Catalyst 2960-S switches in a switch stack.
• Install the FlexStack module and the FlexStack cable for stacking capability.
You can order them in a kit from your Cisco sales representative:
C2960S-STACK=.
• Consider the length of FlexStack cable. Depending on your configurations,
you might need different sized cables. You can order them from your Cisco
sales representative:
– CAB-STK-E-0.5M= (0.5-meter cable)
– CAB-STK-E-1M= (1-meter cable)
– CAB-STK-E-3M= (3-meter cable)
For additional stacking guidelines, see the switch hardware installation guide on
Cisco.com. For concepts and procedures to manage switch stacks, see the switch
software configuration guide on Cisco.com.
15
Catalyst 2960-S Switch Getting Started Guide
OL-19793-02
Catalyst 2960-S Switch Getting Started Guide
Installing the FlexStack Module
Step 1 Use a flat-blade screwdriver to remove the FlexStack module blank cover on the
switch back panel.
Step 2 Grasp the FlexStack module on the sides, and insert it into the module slot.
Step 3 Secure the screws tightly on each side of the module.
Note Make sure the screws are finger-tight to avoid overtightening of the
screws.
206255
206232
RATING
100-240~
12-6A, 50-60Hz
RATING
100-240~
12-6A, 50-60Hz
206239
Catalyst 2960-S Switch Getting Started Guide
16
Catalyst 2960-S Switch Getting Started Guide
OL-19793-02
Cabling Guidelines
These illustrations show the recommended switch stack configurations with
redundant stack cabling connections for optimized stack bandwidth. For more
configuration examples, see the hardware installation guide on Cisco.com.
This is an example of a redundant stack cable connection using the 0.5-meter
FlexStack cable.
206231
17
Catalyst 2960-S Switch Getting Started Guide
OL-19793-02
Catalyst 2960-S Switch Getting Started Guide
This is an example of a redundant stack cable connection using both the 0.5- and
3-meter FlexStack cables.
Powering Guidelines
Consider these guidelines before you power the switches in a stack:
• If you want a particular switch to become the stack master, power on that
switch first. This switch becomes the stack master and remains the stack
master until a master reelection is required. After 2 minutes, power on the
remaining switches in the stack.
• Power off a switch before you add it to or remove it from an existing switch
stack.
For more information on stack master elections, see the “Managing Switch
Stacks” chapter in the switch software configuration guide on Cisco.com.
206230
Catalyst 2960-S Switch Getting Started Guide
18
Catalyst 2960-S Switch Getting Started Guide
OL-19793-02
Rack-Mounting
This section covers basic 19-inch rack-mounting and switch port connections. As
an example, all the illustrations show the Catalyst 2960S-48FPD-L switch. You
can install and connect the other Catalyst 2960-S switches as shown in these
illustrations. For alternate mounting procedures, such as installing the switch in a
24-inch rack or on a wall, and for additional cabling information, see the hardware
installation guide on Cisco.com.
Required Tools
You need to supply a number-2 Phillips screwdriver to rack-mount the switch.
Before You Begin
Before installing the switch, verify that these guidelines are met:
• Clearance to the front panels is sufficient so that the LEDs can be easily read.
• Access to the switch rear panel to connect the optional Cisco Redundant
Power Supply (RPS) 2300 or to stack the switches. If you do not have access
to the rear panel, you should cable the switches before you rack-mount them.
• AC power cord reaches from the AC power outlet to the connector on the
switch rear panel.
• Cabling is away from sources of electrical noise, such as radios, power lines,
and fluorescent lighting fixtures. Make sure the cabling is safely away from
other devices that might damage the cables.
• Airflow around the switch and through the vents is unrestricted.
• Temperature around the unit does not exceed 113°F (45°C). If the switch is
installed in a closed or multirack assembly, the temperature around it might
be greater than normal room temperature.
• Humidity around the switch does not exceed 85 percent.
• Altitude at the installation site is not greater than 10,000 feet.
19
Catalyst 2960-S Switch Getting Started Guide
OL-19793-02
Catalyst 2960-S Switch Getting Started Guide
• For 10/100 or 10/100/1000 fixed ports, cable lengths from the switch to
connected devices can be up to 328 feet (100 meters).
• For cable lengths for small form-factor pluggable (SFP)-module connections,
see the hardware installation guide on Cisco.com and the documentation that
shipped with the module.
Installation Warning Statements
This section includes the basic installation warning statements. Translations of
these warning statements appear in the Regulatory Compliance and Safety
Information for the Catalyst 2960 and 2960-S Switches document on Cisco.com.
Warning To prevent bodily injury when mounting or servicing this unit in a rack, you must
take special precautions to ensure that the system remains stable. The
following guidelines are provided to ensure your safety:
This unit should be mounted at the bottom of the rack if it is the only unit in the
rack.
When mounting this unit in a partially filled rack, load the rack from the bottom
to the top with the heaviest component at the bottom of the rack.
If the rack is provided with stabilizing devices, install the stabilizers before
mounting or servicing the unit in the rack. Statement 1006
Warning Class 1 laser product. Statement 1008
Warning This equipment must be grounded. Never defeat the ground conductor or
operate the equipment in the absence of a suitably installed ground conductor.
Contact the appropriate electrical inspection authority or an electrician if you
are uncertain that suitable grounding is available. Statement 1024
Catalyst 2960-S Switch Getting Started Guide
20
Catalyst 2960-S Switch Getting Started Guide
OL-19793-02
Warning To prevent the system from overheating, do not operate it in an area that
exceeds the maximum recommended ambient temperature of:
<113°F (45°C). Statement 1047
Warning To prevent airflow restriction, allow clearance around the ventilation openings
to be at least:
3 inches (7.6 cm). Statement 1076
Before Attaching Brackets
To install the switch in a rack, you must first remove the screws from the switch
chassis so that the mounting brackets can be attached.
Note You do not need to remove the screws for attaching the brackets in the
rear-mounting position.
252587
39X
38X
47X
48X
1
2
Catalyst 2960-S Series PoE+ 10G
21
Catalyst 2960-S Switch Getting Started Guide
OL-19793-02
Catalyst 2960-S Switch Getting Started Guide
Attaching the Brackets
Use four Phillips flat-head screws to attach the long side of the brackets to
Catalyst 2960-S switches in one of three mounting positions.
1 Front-mounting position 3 Mid-mounting position
2 Number-8 Phillips flat-head screws (48-0655-01) 4 Rear-mounting position
POWER
OVER ETHERN
ET 740W
11X
2X
1X
11X
14X12X
13X
23X
24X
25X
26X
37X 39X
36X 38X
47X
48X
1
2
Catalyst 2960-S Series PoE+ 10G
Catalyst 2960-S Series PoE+ 10G
RATING
100-240~12-6A, 50-60Hz
11X
2X
1X
11X
14X12X
13X
23X
24X
25X
26X
37X 39X
36X 38X
47X
48X
1
2
POWER
OVER ETHERN
ET 740W
Catalyst 2960-S Series PoE+ 10G
206599
2
1
3
4
Catalyst 2960-S Switch Getting Started Guide
22
Catalyst 2960-S Switch Getting Started Guide
OL-19793-02
Rack-Mount the Switch
Use the four number-12 Phillips machine screws to attach the brackets to the rack.
Use the black Phillips machine screw to attach the cable guide to the left or right
bracket.
.
1 Cable guide 4 Number-12 Phillips pan-head screws (48-0523-01)
2 Black Phillips machine screw (48-0654-01) 5 Mid-mounting position
3 Front-mounting position 6 Rear-mounting position
11X
2X
1X
11X
14X12X
13X
23X
24X
25X
26X
37X 39X
36X 38X
47X
48X
1
2
11X
2X
1X
11X
14X12X
13X
23X
24X
25X
26X
37X 39X
36X 38X
47X
48X
1
2
POWER
OVER ETHERN
ET 740W
POWER
OVER ETHERN
ET 740W
Catalyst 2960-S Series
PoE+ 10G
Catalyst 2960-S Series
PoE+ 10G
1
2
206600
RATING
100-240~
12-6A, 50-60Hz
3
4
5
6
23
Catalyst 2960-S Switch Getting Started Guide
OL-19793-02
Catalyst 2960-S Switch Getting Started Guide
Connecting the FlexStack Cables
Always use a Cisco-approved FlexStack cable to connect the switches. Connect
only Catalyst 2960-S switches in a switch stack.
Step 1 Remove the dust covers from the FlexStack cables, and store them for future use.
Step 2 Insert one end of the FlexStack cable into the stack port of the first switch. Insert
the other end of the cable into the stack port on the other switch.
Note When you connect the FlexStack cable into the STACK 1 port, the tab should be
above the connector. When you connect the FlexStack cable into the STACK 2
port, you should invert the cable so that the tab is below the connector.
Step 3 Replace the dust covers when you remove the FlexStack cables from the
connectors.
Removing and installing the FlexStack cable can shorten its useful life. Do not
remove and insert the cable more often than is absolutely necessary.
206235
Catalyst 2960-S Switch Getting Started Guide
24
Catalyst 2960-S Switch Getting Started Guide
OL-19793-02
Connecting to the Switch Ports
This section describes how to connect to the fixed switch ports and to the SFP
module ports.
Connect to the 10/100 or 10/100/1000 Ports
The fixed ports on the Catalyst 2960-S Power over Ethernet Plus (PoE+) switches
provide:
• PoE+ support for IEEE 802.3at-compliant powered devices
• PoE support for IEEE 802.3af-compliant powered devices
• Support for Cisco enhanced PoE (ePoE)
They also provide Cisco prestandard PoE support for Cisco IP phones and Cisco
Aironet Access Points. See the switch hardware guide for information on PoE
budgeting.
By default, a Catalyst 2960-S switch PoE port automatically provides power when
a compliant device is connected, including ePoE, PoE, and PoE+. For information
about configuring and monitoring PoE and PoE+ ports, see the switch software
configuration guide.
Step 1 When you connect to servers, workstations,
IP phones, wireless access points, and routers,
insert a straight-through, twisted four-pair,
Category 5 cable in a switch 10/100 or
10/100/1000 port. Use a crossover, twisted
four-pair, Category 5 cable when you connect
to other switches, hubs, or repeaters.
Step 2 Insert the other cable end into an RJ-45 port on the other device.
11X
14X12X
1X
2X
11X
POWER OVER ETHERNET 740W
206236
25
Catalyst 2960-S Switch Getting Started Guide
OL-19793-02
Catalyst 2960-S Switch Getting Started Guide
Note The automatic medium-dependent interface crossover (auto-MDIX) feature is
enabled by default. The switch detects the required cable type for copper Ethernet
connections and configures the interfaces accordingly. Therefore, you can use
either a crossover or a straight-through cable for connections to a copper 10/100
or 10/100/1000 module port on the switch, regardless of the type of device on the
other end of the connection.
Install the SFP or SFP+ Modules
Some Catalyst 2960-S switches have SFP module slots and others have SFP+
module slots. The SFP slots support only the SFP modules. The SFP+ slots
support both SFP and SFP+ modules.
For a list of supported modules, see the release notes on Cisco.com. For detailed
instructions on installing, removing, and connecting to SFP modules, see the
documentation that came with the SFP module.
Caution Removing and installing an SFP module can shorten its useful life. Do not remove
and insert SFP modules more often than is absolutely necessary.
Step 1 Grasp the module on the sides, and insert it
into the switch slot until you feel the
connector snap into place.
Step 2 Insert an appropriate cable into the module
port. Insert the other cable end into the other
device.
47X
48X
1
2
Catalyst 2960-S Series PoE+ 10G
206237
47X
48X
1
2
Catalyst 2960-S Series PoE+ 10G
Catalyst 2960-S Switch Getting Started Guide
26
Catalyst 2960-S Switch Getting Started Guide
OL-19793-02
Verify Port Connectivity
After you connect the switch port and another device, the port LED turns amber
while the switch establishes a link. This process takes about 30 seconds, and then
the LED turns green. If the LED turns off, the target device might not be turned
on, there might be a cable problem, or there might be a problem with the adapter
installed in the target device. See the “In Case of Difficulty” section on page 26
for information about online assistance.
In Case of Difficulty
If you experience difficulty, help is available in this section and also on
Cisco.com. This section includes Express Setup troubleshooting, how to reset the
switch, how to access help online, and where to find more information.
Troubleshooting Express Setup
If Express Setup does not run, or if the Express Setup page does not appear in your
browser:
Did you verify that POST ran
successfully before starting
Express Setup?
If not, make sure that only the SYST and
STAT LEDs are green before you press the
Mode button to enter the Express Setup
mode.
POST errors are usually fatal. Contact your
Cisco technical support representative if your
switch fails POST.
Did you press the Mode button
while the switch was still running
POST?
If yes, wait until POST completes. Power
cycle the switch. Wait until POST completes.
Confirm that the SYST and STAT LEDs are
green. Press the Mode button to enter
Express Setup mode.
27
Catalyst 2960-S Switch Getting Started Guide
OL-19793-02
Catalyst 2960-S Switch Getting Started Guide
Did you try to continue without
confirming that the switch was in
Express Setup mode?
Verify that all LEDs above the Mode button
are green. (The RPS LED is off.) If
necessary, press the Mode button to enter
Express Setup mode.
Does your PC have a static IP
address?
If yes, before connecting to the switch,
change your PC settings to temporarily use
DHCP.
Did you connect a crossover
cable instead of a
straight-through Ethernet cable
between a switch port and the
Ethernet port of the PC?
If yes, connect a straight-through cable to an
Ethernet port on the switch and the PC. Wait
30 seconds before you enter 10.0.0.1 in the
browser.
Did you connect the Ethernet
cable to the console port instead
of to a 10/100 or 10/100/1000
Ethernet port on the switch?
If yes, disconnect the cable from the console
port. Then connect the cable to an Ethernet
port on the switch and the PC. Wait 30
seconds before you enter 10.0.0.1 in the
browser.
Note The console port is outlined in blue,
and the Ethernet port is outlined in
yellow.
Did you wait 30 seconds after you
connected the switch and the PC
before you entered the IP address
in your browser?
If not, wait 30 seconds, re-enter 10.0.0.1 in
the browser, and press Enter.
Did you enter the wrong address
in the browser, or is there an error
message?
If yes, re-enter 10.0.0.1 in the browser, and
press Enter.
Catalyst 2960-S Switch Getting Started Guide
28
Catalyst 2960-S Switch Getting Started Guide
OL-19793-02
Resetting the Switch
Follow these steps to return your switch to the factory default settings. These are
reasons why you might want to reset the switch:
• You installed the switch in your network and cannot connect to it because you
assigned the wrong IP address.
• You want to clear all configurations from the switch and assign a new IP
address.
• You want to reset the password on the switch.
Caution Resetting the switch deletes the configuration and reboots the switch.
To reset the switch:
Press and hold the Mode button. The switch LEDs begin blinking after about
3 seconds. Continue holding down the Mode button. The LEDs stop blinking after
7 more seconds, and then the switch reboots.
The switch now behaves like an unconfigured switch. You can enter the switch IP
information by using Express Setup as described in the “Running Express Setup”
section on page 4.
Accessing Help Online
First look for a solution to your problem in the troubleshooting section of the
switch hardware installation guide or the switch software configuration guide on
Cisco.com. You can also access the Cisco Technical Support and Documentation
website for a list of known hardware problems and extensive troubleshooting
documentation.
29
Catalyst 2960-S Switch Getting Started Guide
OL-19793-02
Catalyst 2960-S Switch Getting Started Guide
For More Information
For more information about the switch, see these documents on Cisco.com:
• Catalyst 2960-S Switch Hardware Installation Guide
• Regulatory Compliance and Safety Information for the Catalyst 2960
and 2960-S Switches
• Release Notes for the Catalyst 2960-S Switch
• Catalyst 2960 and 2960-S Switch Software Configuration Guide
• Catalyst 2960 and 2960-S Switch Command Reference
• Catalyst 3750, 3560, 2975, 2960, and 2960-S Switch System Message Guide
• Device Manager online help (available on the switch)
• Cisco Small Form-Factor Pluggable Modules Installation Notes
Obtaining Documentation and Submitting a
Service Request
For information on obtaining documentation, submitting a service request, and
gathering additional information, see the monthly What’s New in Cisco Product
Documentation, which also lists all new and revised Cisco technical
documentation, at:
http://www.cisco.com/en/US/docs/general/whatsnew/whatsnew.html
Subscribe to the What’s New in Cisco Product Documentation as a Really Simple
Syndication (RSS) feed and set content to be delivered directly to your desktop using
a reader application. The RSS feeds are a free service and Cisco currently supports
RSS version 2.0.
Cisco and the Cisco logo are trademarks or registered trademarks of Cisco and/or its affiliates in the U.S. and other
countries. To view a list of Cisco trademarks, go to this URL: www.cisco.com/go/trademarks. Third-party
trademarks mentioned are the property of their respective owners. The use of the word partner does not imply a
partnership relationship between Cisco and any other company. (1110R)
Any Internet Protocol (IP) addresses used in this document are not intended to be actual addresses. Any examples,
command display output, and figures included in the document are shown for illustrative purposes only. Any use of
actual IP addresses in illustrative content is unintentional and coincidental.
© 2010-2012 Cisco Systems, Inc. All rights reserved.
Catalyst 2960-S Switch Getting Started Guide
30
Catalyst 2960-S Switch Getting Started Guide
OL-19793-02

More Related Content

What's hot

Ursalink UR71 Industrial Cellular Router Quick Start Guide
Ursalink UR71 Industrial Cellular Router Quick Start GuideUrsalink UR71 Industrial Cellular Router Quick Start Guide
Ursalink UR71 Industrial Cellular Router Quick Start GuideIvete Huang
 
Cisco switch catalyst 2960 x datasheet
Cisco switch catalyst 2960 x datasheetCisco switch catalyst 2960 x datasheet
Cisco switch catalyst 2960 x datasheetAmy Huang
 
Tolomatic electric stepper products brochure
Tolomatic electric stepper products brochureTolomatic electric stepper products brochure
Tolomatic electric stepper products brochureElectromate
 
Catalog PLC Fuji Electric mới nhất 2019
Catalog PLC Fuji Electric mới nhất 2019Catalog PLC Fuji Electric mới nhất 2019
Catalog PLC Fuji Electric mới nhất 2019CTY TNHH HẠO PHƯƠNG
 
Datasheet EnGenius EWS360AP
Datasheet EnGenius EWS360APDatasheet EnGenius EWS360AP
Datasheet EnGenius EWS360APEnGenius Europe
 
Ursalink UR51 Industrial Cellular Router Quick Start Guide
Ursalink UR51 Industrial Cellular Router Quick Start GuideUrsalink UR51 Industrial Cellular Router Quick Start Guide
Ursalink UR51 Industrial Cellular Router Quick Start GuideIvete Huang
 
Electro-Hydraulic Damper Drives for Combustion Control
Electro-Hydraulic Damper Drives for Combustion ControlElectro-Hydraulic Damper Drives for Combustion Control
Electro-Hydraulic Damper Drives for Combustion ControlClassic Controls, Inc.
 
Fuel Air Ratio Controller for Combustion Efficiency
Fuel Air Ratio Controller for Combustion EfficiencyFuel Air Ratio Controller for Combustion Efficiency
Fuel Air Ratio Controller for Combustion EfficiencyClassic Controls, Inc.
 
Segmented Ball Control Valve for Natural Gas Operations
Segmented Ball Control Valve for Natural Gas OperationsSegmented Ball Control Valve for Natural Gas Operations
Segmented Ball Control Valve for Natural Gas OperationsClassic Controls, Inc.
 
Packet Tracer Simulation Lab Layer3 Routing
Packet Tracer Simulation Lab Layer3 RoutingPacket Tracer Simulation Lab Layer3 Routing
Packet Tracer Simulation Lab Layer3 RoutingJohnson Liu
 
Ds 8602 smart_router_74_c0007 (1)
Ds 8602 smart_router_74_c0007 (1)Ds 8602 smart_router_74_c0007 (1)
Ds 8602 smart_router_74_c0007 (1)Hossein Abbasi
 
Olive Introduction for TOI
Olive Introduction for TOIOlive Introduction for TOI
Olive Introduction for TOIJohnson Liu
 
Packet Tracer Simulation Lab Layer 2 Switching
Packet Tracer Simulation Lab Layer 2 SwitchingPacket Tracer Simulation Lab Layer 2 Switching
Packet Tracer Simulation Lab Layer 2 SwitchingJohnson Liu
 
How to configure a catalyst 3750 x
How to configure a catalyst 3750 xHow to configure a catalyst 3750 x
How to configure a catalyst 3750 x3Anetwork com
 

What's hot (19)

Abb softstartery pstx kat_en15
Abb softstartery pstx kat_en15Abb softstartery pstx kat_en15
Abb softstartery pstx kat_en15
 
DVC
DVCDVC
DVC
 
Ursalink UR71 Industrial Cellular Router Quick Start Guide
Ursalink UR71 Industrial Cellular Router Quick Start GuideUrsalink UR71 Industrial Cellular Router Quick Start Guide
Ursalink UR71 Industrial Cellular Router Quick Start Guide
 
Cisco switch catalyst 2960 x datasheet
Cisco switch catalyst 2960 x datasheetCisco switch catalyst 2960 x datasheet
Cisco switch catalyst 2960 x datasheet
 
Tolomatic electric stepper products brochure
Tolomatic electric stepper products brochureTolomatic electric stepper products brochure
Tolomatic electric stepper products brochure
 
Catalog PLC Fuji Electric mới nhất 2019
Catalog PLC Fuji Electric mới nhất 2019Catalog PLC Fuji Electric mới nhất 2019
Catalog PLC Fuji Electric mới nhất 2019
 
Catalog PLC Fuji Electric
Catalog PLC Fuji ElectricCatalog PLC Fuji Electric
Catalog PLC Fuji Electric
 
Datasheet EnGenius EWS360AP
Datasheet EnGenius EWS360APDatasheet EnGenius EWS360AP
Datasheet EnGenius EWS360AP
 
Ursalink UR51 Industrial Cellular Router Quick Start Guide
Ursalink UR51 Industrial Cellular Router Quick Start GuideUrsalink UR51 Industrial Cellular Router Quick Start Guide
Ursalink UR51 Industrial Cellular Router Quick Start Guide
 
Electro-Hydraulic Damper Drives for Combustion Control
Electro-Hydraulic Damper Drives for Combustion ControlElectro-Hydraulic Damper Drives for Combustion Control
Electro-Hydraulic Damper Drives for Combustion Control
 
Fuel Air Ratio Controller for Combustion Efficiency
Fuel Air Ratio Controller for Combustion EfficiencyFuel Air Ratio Controller for Combustion Efficiency
Fuel Air Ratio Controller for Combustion Efficiency
 
96x1 poeers2550t
96x1 poeers2550t96x1 poeers2550t
96x1 poeers2550t
 
Segmented Ball Control Valve for Natural Gas Operations
Segmented Ball Control Valve for Natural Gas OperationsSegmented Ball Control Valve for Natural Gas Operations
Segmented Ball Control Valve for Natural Gas Operations
 
Packet Tracer Simulation Lab Layer3 Routing
Packet Tracer Simulation Lab Layer3 RoutingPacket Tracer Simulation Lab Layer3 Routing
Packet Tracer Simulation Lab Layer3 Routing
 
Ds 8602 smart_router_74_c0007 (1)
Ds 8602 smart_router_74_c0007 (1)Ds 8602 smart_router_74_c0007 (1)
Ds 8602 smart_router_74_c0007 (1)
 
Ssr 303 user manual
Ssr 303 user manualSsr 303 user manual
Ssr 303 user manual
 
Olive Introduction for TOI
Olive Introduction for TOIOlive Introduction for TOI
Olive Introduction for TOI
 
Packet Tracer Simulation Lab Layer 2 Switching
Packet Tracer Simulation Lab Layer 2 SwitchingPacket Tracer Simulation Lab Layer 2 Switching
Packet Tracer Simulation Lab Layer 2 Switching
 
How to configure a catalyst 3750 x
How to configure a catalyst 3750 xHow to configure a catalyst 3750 x
How to configure a catalyst 3750 x
 

Similar to Cisco Files

huawei-s5735-s48u4xe-v2-brochure-datasheet.pdf
huawei-s5735-s48u4xe-v2-brochure-datasheet.pdfhuawei-s5735-s48u4xe-v2-brochure-datasheet.pdf
huawei-s5735-s48u4xe-v2-brochure-datasheet.pdfHi-Network.com
 
Configuring the cisco switch with the cli based setup program
Configuring the cisco switch with the cli based setup programConfiguring the cisco switch with the cli based setup program
Configuring the cisco switch with the cli based setup program3Anetwork com
 
huawei-s5735-s24p4xe-v2-brochure-datasheet.pdf
huawei-s5735-s24p4xe-v2-brochure-datasheet.pdfhuawei-s5735-s24p4xe-v2-brochure-datasheet.pdf
huawei-s5735-s24p4xe-v2-brochure-datasheet.pdfHi-Network.com
 
Practica_Configuracion_Basica_SW_Cisco
Practica_Configuracion_Basica_SW_CiscoPractica_Configuracion_Basica_SW_Cisco
Practica_Configuracion_Basica_SW_CiscoRanghel Soto Espinoza
 
huawei-s5735-s24hs4xe-v2-brochure-datasheet.pdf
huawei-s5735-s24hs4xe-v2-brochure-datasheet.pdfhuawei-s5735-s24hs4xe-v2-brochure-datasheet.pdf
huawei-s5735-s24hs4xe-v2-brochure-datasheet.pdfHi-Network.com
 
Ccnp3 lab 3_1_en (hacer)
Ccnp3 lab 3_1_en (hacer)Ccnp3 lab 3_1_en (hacer)
Ccnp3 lab 3_1_en (hacer)Omar Herrera
 
huawei-s5735-s24st4xe-v2-brochure-datasheet.pdf
huawei-s5735-s24st4xe-v2-brochure-datasheet.pdfhuawei-s5735-s24st4xe-v2-brochure-datasheet.pdf
huawei-s5735-s24st4xe-v2-brochure-datasheet.pdfHi-Network.com
 
Exercise 4c stp rapid pvst+ question
Exercise 4c   stp rapid pvst+ questionExercise 4c   stp rapid pvst+ question
Exercise 4c stp rapid pvst+ questionsufi1248
 
huawei-s5731-s24un4x2q-brochure-datasheet.pdf
huawei-s5731-s24un4x2q-brochure-datasheet.pdfhuawei-s5731-s24un4x2q-brochure-datasheet.pdf
huawei-s5731-s24un4x2q-brochure-datasheet.pdfHi-Network.com
 
Stacking cisco 3750 switches benefits & stacking rules
Stacking cisco 3750 switches benefits & stacking rulesStacking cisco 3750 switches benefits & stacking rules
Stacking cisco 3750 switches benefits & stacking rulesIT Tech
 
Stacking cisco 3750 switches benefits & stacking rules
Stacking cisco 3750 switches benefits & stacking rulesStacking cisco 3750 switches benefits & stacking rules
Stacking cisco 3750 switches benefits & stacking rulesIT Tech
 
Edge switch es-24_qsg
Edge switch es-24_qsgEdge switch es-24_qsg
Edge switch es-24_qsgRogelio Soto
 
Cisco catalyst 3850-48t-s datasheet
Cisco catalyst 3850-48t-s datasheetCisco catalyst 3850-48t-s datasheet
Cisco catalyst 3850-48t-s datasheetMark Tsui
 
Cisco catalyst 2960 series switches overview
Cisco catalyst 2960 series switches overviewCisco catalyst 2960 series switches overview
Cisco catalyst 2960 series switches overview3Anetwork com
 
Cisco labs practical6
Cisco labs practical6Cisco labs practical6
Cisco labs practical6Tai Lam
 
huawei-s5731-s24n4x2q-a-brochure-datasheet.pdf
huawei-s5731-s24n4x2q-a-brochure-datasheet.pdfhuawei-s5731-s24n4x2q-a-brochure-datasheet.pdf
huawei-s5731-s24n4x2q-a-brochure-datasheet.pdfHi-Network.com
 
Cisco catalyst 3560 c and 2960-c series compact install guide
Cisco catalyst 3560 c and 2960-c series compact install guideCisco catalyst 3560 c and 2960-c series compact install guide
Cisco catalyst 3560 c and 2960-c series compact install guideo3428375
 
Cisco catalyst 2960x 24 ts-l datasheet
Cisco catalyst 2960x 24 ts-l datasheetCisco catalyst 2960x 24 ts-l datasheet
Cisco catalyst 2960x 24 ts-l datasheetMark Tsui
 

Similar to Cisco Files (20)

huawei-s5735-s48u4xe-v2-brochure-datasheet.pdf
huawei-s5735-s48u4xe-v2-brochure-datasheet.pdfhuawei-s5735-s48u4xe-v2-brochure-datasheet.pdf
huawei-s5735-s48u4xe-v2-brochure-datasheet.pdf
 
Configuring the cisco switch with the cli based setup program
Configuring the cisco switch with the cli based setup programConfiguring the cisco switch with the cli based setup program
Configuring the cisco switch with the cli based setup program
 
huawei-s5735-s24p4xe-v2-brochure-datasheet.pdf
huawei-s5735-s24p4xe-v2-brochure-datasheet.pdfhuawei-s5735-s24p4xe-v2-brochure-datasheet.pdf
huawei-s5735-s24p4xe-v2-brochure-datasheet.pdf
 
Practica_Configuracion_Basica_SW_Cisco
Practica_Configuracion_Basica_SW_CiscoPractica_Configuracion_Basica_SW_Cisco
Practica_Configuracion_Basica_SW_Cisco
 
huawei-s5735-s24hs4xe-v2-brochure-datasheet.pdf
huawei-s5735-s24hs4xe-v2-brochure-datasheet.pdfhuawei-s5735-s24hs4xe-v2-brochure-datasheet.pdf
huawei-s5735-s24hs4xe-v2-brochure-datasheet.pdf
 
Ccnp3 lab 3_1_en (hacer)
Ccnp3 lab 3_1_en (hacer)Ccnp3 lab 3_1_en (hacer)
Ccnp3 lab 3_1_en (hacer)
 
huawei-s5735-s24st4xe-v2-brochure-datasheet.pdf
huawei-s5735-s24st4xe-v2-brochure-datasheet.pdfhuawei-s5735-s24st4xe-v2-brochure-datasheet.pdf
huawei-s5735-s24st4xe-v2-brochure-datasheet.pdf
 
Exercise 4c stp rapid pvst+ question
Exercise 4c   stp rapid pvst+ questionExercise 4c   stp rapid pvst+ question
Exercise 4c stp rapid pvst+ question
 
huawei-s5731-s24un4x2q-brochure-datasheet.pdf
huawei-s5731-s24un4x2q-brochure-datasheet.pdfhuawei-s5731-s24un4x2q-brochure-datasheet.pdf
huawei-s5731-s24un4x2q-brochure-datasheet.pdf
 
Stacking cisco 3750 switches benefits & stacking rules
Stacking cisco 3750 switches benefits & stacking rulesStacking cisco 3750 switches benefits & stacking rules
Stacking cisco 3750 switches benefits & stacking rules
 
Stacking cisco 3750 switches benefits & stacking rules
Stacking cisco 3750 switches benefits & stacking rulesStacking cisco 3750 switches benefits & stacking rules
Stacking cisco 3750 switches benefits & stacking rules
 
EMEA Airheads- Switch stacking_ ArubaOS Switch
EMEA Airheads- Switch stacking_ ArubaOS SwitchEMEA Airheads- Switch stacking_ ArubaOS Switch
EMEA Airheads- Switch stacking_ ArubaOS Switch
 
Edge switch es-24_qsg
Edge switch es-24_qsgEdge switch es-24_qsg
Edge switch es-24_qsg
 
Cisco catalyst 3850-48t-s datasheet
Cisco catalyst 3850-48t-s datasheetCisco catalyst 3850-48t-s datasheet
Cisco catalyst 3850-48t-s datasheet
 
Cisco catalyst 2960 series switches overview
Cisco catalyst 2960 series switches overviewCisco catalyst 2960 series switches overview
Cisco catalyst 2960 series switches overview
 
Cisco labs practical6
Cisco labs practical6Cisco labs practical6
Cisco labs practical6
 
huawei-s5731-s24n4x2q-a-brochure-datasheet.pdf
huawei-s5731-s24n4x2q-a-brochure-datasheet.pdfhuawei-s5731-s24n4x2q-a-brochure-datasheet.pdf
huawei-s5731-s24n4x2q-a-brochure-datasheet.pdf
 
PROYECTO VLANS
PROYECTO VLANSPROYECTO VLANS
PROYECTO VLANS
 
Cisco catalyst 3560 c and 2960-c series compact install guide
Cisco catalyst 3560 c and 2960-c series compact install guideCisco catalyst 3560 c and 2960-c series compact install guide
Cisco catalyst 3560 c and 2960-c series compact install guide
 
Cisco catalyst 2960x 24 ts-l datasheet
Cisco catalyst 2960x 24 ts-l datasheetCisco catalyst 2960x 24 ts-l datasheet
Cisco catalyst 2960x 24 ts-l datasheet
 

Recently uploaded

Streamlining Python Development: A Guide to a Modern Project Setup
Streamlining Python Development: A Guide to a Modern Project SetupStreamlining Python Development: A Guide to a Modern Project Setup
Streamlining Python Development: A Guide to a Modern Project SetupFlorian Wilhelm
 
Gen AI in Business - Global Trends Report 2024.pdf
Gen AI in Business - Global Trends Report 2024.pdfGen AI in Business - Global Trends Report 2024.pdf
Gen AI in Business - Global Trends Report 2024.pdfAddepto
 
Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)
Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)
Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)Mark Simos
 
AI as an Interface for Commercial Buildings
AI as an Interface for Commercial BuildingsAI as an Interface for Commercial Buildings
AI as an Interface for Commercial BuildingsMemoori
 
"Debugging python applications inside k8s environment", Andrii Soldatenko
"Debugging python applications inside k8s environment", Andrii Soldatenko"Debugging python applications inside k8s environment", Andrii Soldatenko
"Debugging python applications inside k8s environment", Andrii SoldatenkoFwdays
 
Are Multi-Cloud and Serverless Good or Bad?
Are Multi-Cloud and Serverless Good or Bad?Are Multi-Cloud and Serverless Good or Bad?
Are Multi-Cloud and Serverless Good or Bad?Mattias Andersson
 
Story boards and shot lists for my a level piece
Story boards and shot lists for my a level pieceStory boards and shot lists for my a level piece
Story boards and shot lists for my a level piececharlottematthew16
 
Scanning the Internet for External Cloud Exposures via SSL Certs
Scanning the Internet for External Cloud Exposures via SSL CertsScanning the Internet for External Cloud Exposures via SSL Certs
Scanning the Internet for External Cloud Exposures via SSL CertsRizwan Syed
 
SQL Database Design For Developers at php[tek] 2024
SQL Database Design For Developers at php[tek] 2024SQL Database Design For Developers at php[tek] 2024
SQL Database Design For Developers at php[tek] 2024Scott Keck-Warren
 
SAP Build Work Zone - Overview L2-L3.pptx
SAP Build Work Zone - Overview L2-L3.pptxSAP Build Work Zone - Overview L2-L3.pptx
SAP Build Work Zone - Overview L2-L3.pptxNavinnSomaal
 
WordPress Websites for Engineers: Elevate Your Brand
WordPress Websites for Engineers: Elevate Your BrandWordPress Websites for Engineers: Elevate Your Brand
WordPress Websites for Engineers: Elevate Your Brandgvaughan
 
Connect Wave/ connectwave Pitch Deck Presentation
Connect Wave/ connectwave Pitch Deck PresentationConnect Wave/ connectwave Pitch Deck Presentation
Connect Wave/ connectwave Pitch Deck PresentationSlibray Presentation
 
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...Patryk Bandurski
 
APIForce Zurich 5 April Automation LPDG
APIForce Zurich 5 April  Automation LPDGAPIForce Zurich 5 April  Automation LPDG
APIForce Zurich 5 April Automation LPDGMarianaLemus7
 
CloudStudio User manual (basic edition):
CloudStudio User manual (basic edition):CloudStudio User manual (basic edition):
CloudStudio User manual (basic edition):comworks
 
Bun (KitWorks Team Study 노별마루 발표 2024.4.22)
Bun (KitWorks Team Study 노별마루 발표 2024.4.22)Bun (KitWorks Team Study 노별마루 발표 2024.4.22)
Bun (KitWorks Team Study 노별마루 발표 2024.4.22)Wonjun Hwang
 
Advanced Test Driven-Development @ php[tek] 2024
Advanced Test Driven-Development @ php[tek] 2024Advanced Test Driven-Development @ php[tek] 2024
Advanced Test Driven-Development @ php[tek] 2024Scott Keck-Warren
 
My Hashitalk Indonesia April 2024 Presentation
My Hashitalk Indonesia April 2024 PresentationMy Hashitalk Indonesia April 2024 Presentation
My Hashitalk Indonesia April 2024 PresentationRidwan Fadjar
 
Commit 2024 - Secret Management made easy
Commit 2024 - Secret Management made easyCommit 2024 - Secret Management made easy
Commit 2024 - Secret Management made easyAlfredo García Lavilla
 
New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024BookNet Canada
 

Recently uploaded (20)

Streamlining Python Development: A Guide to a Modern Project Setup
Streamlining Python Development: A Guide to a Modern Project SetupStreamlining Python Development: A Guide to a Modern Project Setup
Streamlining Python Development: A Guide to a Modern Project Setup
 
Gen AI in Business - Global Trends Report 2024.pdf
Gen AI in Business - Global Trends Report 2024.pdfGen AI in Business - Global Trends Report 2024.pdf
Gen AI in Business - Global Trends Report 2024.pdf
 
Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)
Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)
Tampa BSides - Chef's Tour of Microsoft Security Adoption Framework (SAF)
 
AI as an Interface for Commercial Buildings
AI as an Interface for Commercial BuildingsAI as an Interface for Commercial Buildings
AI as an Interface for Commercial Buildings
 
"Debugging python applications inside k8s environment", Andrii Soldatenko
"Debugging python applications inside k8s environment", Andrii Soldatenko"Debugging python applications inside k8s environment", Andrii Soldatenko
"Debugging python applications inside k8s environment", Andrii Soldatenko
 
Are Multi-Cloud and Serverless Good or Bad?
Are Multi-Cloud and Serverless Good or Bad?Are Multi-Cloud and Serverless Good or Bad?
Are Multi-Cloud and Serverless Good or Bad?
 
Story boards and shot lists for my a level piece
Story boards and shot lists for my a level pieceStory boards and shot lists for my a level piece
Story boards and shot lists for my a level piece
 
Scanning the Internet for External Cloud Exposures via SSL Certs
Scanning the Internet for External Cloud Exposures via SSL CertsScanning the Internet for External Cloud Exposures via SSL Certs
Scanning the Internet for External Cloud Exposures via SSL Certs
 
SQL Database Design For Developers at php[tek] 2024
SQL Database Design For Developers at php[tek] 2024SQL Database Design For Developers at php[tek] 2024
SQL Database Design For Developers at php[tek] 2024
 
SAP Build Work Zone - Overview L2-L3.pptx
SAP Build Work Zone - Overview L2-L3.pptxSAP Build Work Zone - Overview L2-L3.pptx
SAP Build Work Zone - Overview L2-L3.pptx
 
WordPress Websites for Engineers: Elevate Your Brand
WordPress Websites for Engineers: Elevate Your BrandWordPress Websites for Engineers: Elevate Your Brand
WordPress Websites for Engineers: Elevate Your Brand
 
Connect Wave/ connectwave Pitch Deck Presentation
Connect Wave/ connectwave Pitch Deck PresentationConnect Wave/ connectwave Pitch Deck Presentation
Connect Wave/ connectwave Pitch Deck Presentation
 
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
Integration and Automation in Practice: CI/CD in Mule Integration and Automat...
 
APIForce Zurich 5 April Automation LPDG
APIForce Zurich 5 April  Automation LPDGAPIForce Zurich 5 April  Automation LPDG
APIForce Zurich 5 April Automation LPDG
 
CloudStudio User manual (basic edition):
CloudStudio User manual (basic edition):CloudStudio User manual (basic edition):
CloudStudio User manual (basic edition):
 
Bun (KitWorks Team Study 노별마루 발표 2024.4.22)
Bun (KitWorks Team Study 노별마루 발표 2024.4.22)Bun (KitWorks Team Study 노별마루 발표 2024.4.22)
Bun (KitWorks Team Study 노별마루 발표 2024.4.22)
 
Advanced Test Driven-Development @ php[tek] 2024
Advanced Test Driven-Development @ php[tek] 2024Advanced Test Driven-Development @ php[tek] 2024
Advanced Test Driven-Development @ php[tek] 2024
 
My Hashitalk Indonesia April 2024 Presentation
My Hashitalk Indonesia April 2024 PresentationMy Hashitalk Indonesia April 2024 Presentation
My Hashitalk Indonesia April 2024 Presentation
 
Commit 2024 - Secret Management made easy
Commit 2024 - Secret Management made easyCommit 2024 - Secret Management made easy
Commit 2024 - Secret Management made easy
 
New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
New from BookNet Canada for 2024: BNC CataList - Tech Forum 2024
 

Cisco Files

  • 1. 1 Catalyst 2960-S Switch Getting Started Guide OL-19793-02 Catalyst 2960-S Switch Getting Started Guide • About This Guide • Unpacking the Switch • Running Express Setup • Managing the Switch • Planning and Creating Switch Stacks • Rack-Mounting • Connecting the FlexStack Cables • Connecting to the Switch Ports • In Case of Difficulty • Obtaining Documentation and Submitting a Service Request
  • 2. Catalyst 2960-S Switch Getting Started Guide 2 Catalyst 2960-S Switch Getting Started Guide OL-19793-02 About This Guide This guide provides instructions on how to use Express Setup to initially configure your Catalyst switch. It also covers switch management options, basic rack-mounting, stacking guidelines, port and module connection procedures, and troubleshooting help. For additional installation and configuration information for the switch, see the Catalyst 2960 documentation on Cisco.com. For system requirements, important notes, limitations, open and resolved bugs, and last-minute documentation updates, see the release notes, also on Cisco.com. For translations of the warnings that appear in this publication, see the Regulatory Compliance and Safety Information for the Catalyst 2960 and 2960-S Switches on Cisco.com. When using the online publications, see the documents that match the Cisco IOS software version running on the switch. The software version is on the Cisco IOS label on the switch rear panel. Unpacking the Switch Follow these steps: 1. Unpack and remove the switch and the accessory kit from the shipping box. 2. Return the packing material to the shipping container, and save it for future use. 3. Verify that you have received these items. If any item is missing or damaged, contact your Cisco representative or reseller for instructions.
  • 3. 3 Catalyst 2960-S Switch Getting Started Guide OL-19793-02 Catalyst 2960-S Switch Getting Started Guide 1 Catalyst 2960-S switch1 1. Catalyst 2960S-48FPD-L switch shown for example. Your switch model might look different. 9 Four number-8 Phillips truss-head screws (48-0656-01) 2 AC power cord 10 Four number-8 Phillips flat-head screws (48-0655-01) 3 Four rubber mounting feet 11 Two number-4 pan-head screws (48-0482-01) 4 Documentation 12 One black Phillips machine screw (48-0654-01) 5 Two 19-inch mounting brackets 13 (Optional3 ) Console cable or USB cable 6 Connector2 cover for redundant power system 2. Only available on some models. 14 (Optional3 ) Cisco FlexStack module 7 Cable guide 15 (Optional3 ) Cisco FlexStack cable 8 Four number-12 Phillips pan-head screws (48-0523-01) 16 (Optional3 ) Power cord retainer 3. Item is orderable. C atalyst2960-S S w itch D ocum entation Catalyst 2960-S Series PoE+ 10G 11X 2X 1X 11X 14X12X 13X 23X 24X 25X 26X 37X 39X 36X 38X 47X 48X 1 2 POWER OVER ETHERN ET 740W 8 9 10 4 5 6 11 13 2 7 12 1 3 14 15 16 206224
  • 4. Catalyst 2960-S Switch Getting Started Guide 4 Catalyst 2960-S Switch Getting Started Guide OL-19793-02 Running Express Setup When you first set up the switch, you should use Express Setup to enter the initial IP information. Doing this enables the switch to connect to local routers and the network. You can then access the switch through the IP address for further configuration. You need this equipment to set up the switch: • A PC with Windows 2000, XP, Vista, or Windows Server 2003 installed • A web browser (Internet Explorer 6.0, 7.0, Firefox 1.5, 2.0, or later) with JavaScript enabled Note Other laptops and browsers might work. • A straight-through or crossover Category 5 or 6 Ethernet cable to connect your PC to the switch Note Before running Express Setup, disable any pop-up blockers or proxy settings in your browser software and any wireless client running on your PC. Step 1 Make sure that nothing is connected to the switch. Step 2 During Express Setup, the switch acts as a DHCP server. If your PC has a static IP address, temporarily configure your PC settings to use DHCP before proceeding to the next step. Note Write down the static IP address. You will need this IP address in Step 10. Cataly st 2960-S Series PoE+ 10G 11X 2X 1X 11X 14X12X 13X 23X 24X 25X 26X 37X 39X 36X 38X 47X 48X 1 2 206225
  • 5. 5 Catalyst 2960-S Switch Getting Started Guide OL-19793-02 Catalyst 2960-S Switch Getting Started Guide Step 3 Power the switch by connecting the AC power cord to the switch power supply and to a grounded AC outlet. Approximately 30 seconds after the switch powers on, it begins the power-on self-test (POST), which can take several minutes to complete. During POST, the SYSTEM LED blinks green, and the RPS, STATUS, DUPLEX, and SPEED LEDs turn solid green. When POST is complete, the SYSTEM LED remains solid green, and the other LEDs go off. The exception is the STACKMASTER LED, which remains solid green if the switch is stackable and is acting as stack master. Before proceeding to the next step, wait until POST is complete. This might take up to 5 minutes after the switch is powered on. Troubleshooting: If the SYSTEM LED blinks green, does not turn solid green, or turns amber, contact your Cisco representative or reseller. The switch failed the power-on self-test (POST). RATING 100-240~12-6A, 50-60Hz 206226
  • 6. Catalyst 2960-S Switch Getting Started Guide 6 Catalyst 2960-S Switch Getting Started Guide OL-19793-02 Step 4 Press and hold the Mode button until all of the LEDs above the Mode button turn solid green. You might need to hold the button for 3 or more seconds. Release the Mode button after all of the LEDs above the Mode button turn solid green. (The RPS LED remains off on some switch models, and is not present on all models.) The switch is now in Express Setup mode. Before proceeding to the next step, make sure that all of the LEDs above the Mode button are solid green. Troubleshooting: If the LEDs above the Mode button blink after you press the button, release it. Blinking LEDs mean that the switch is already configured and cannot go into Express Setup mode. For more information, see the “Resetting the Switch” section on page 28. Cataly st 2960-S Series PoE+ 10G 11X 2X 1X 11X 14X12X 13X 23X 24X 25X 26X 37X 39X 36X 38X 47X 48X 1 2 206598
  • 7. 7 Catalyst 2960-S Switch Getting Started Guide OL-19793-02 Catalyst 2960-S Switch Getting Started Guide Step 5 Connect a Category 5 or 6 Ethernet cable to one of these locations: • Any 10/100 or 10/100/1000 Ethernet downlink port (such as port 1) on the switch front panel. • The Ethernet management port on the switch front panel. Connect the other end of the cable to the Ethernet port on your PC. Before proceeding to the next step, wait until the port LEDs on the switch and your PC or laptop are green (either solid or blinking). The green port LEDs indicate a successful connection. Troubleshooting: If the port LEDs do not turn green after about 30 seconds, make sure that: • You connected the Ethernet cable to one of the downlink switch ports (not to an uplink port such as the dual-purpose port). • You are using an undamaged Category 5 or 6 Ethernet cable. • The other device is turned on. Catalys t 2960XS Series PoE 10G 11X 2X 1X 11X 14X12X 13X 23X 24X 25X 26X 37X 39X 36X 38X 47X 48X 1 2 206228
  • 8. Catalyst 2960-S Switch Getting Started Guide 8 Catalyst 2960-S Switch Getting Started Guide OL-19793-02 Step 6 Enter the IP address 10.0.0.1 in a web browser and press Enter. When prompted, enter the default password, cisco. Note The switch ignores text in the username field. The Express Setup window appears. Troubleshooting: If the Express Setup window does not appear, make sure that any pop-up blockers or proxy settings on your browser are disabled and that any wireless client is disabled on your PC or laptop.
  • 9. 9 Catalyst 2960-S Switch Getting Started Guide OL-19793-02 Catalyst 2960-S Switch Getting Started Guide Step 7 Enter the required settings in the Express Setup window. Note All entries must be in English letters and numbers. Required Fields Enter this information in the Network Settings fields: • In the Management Interface (VLAN ID) field, the default is 1. Note We recommend using the default VLAN value because during Express Setup, VLAN 1 is the only VLAN on the switch. Enter a new VLAN ID only if you want to change the management interface through which you manage the switch. The VLAN ID range is 1 to 1001. • In the IP Address field, enter the IP address of the switch. • In the Subnet Mask field, click the drop-down arrow, and select a subnet mask. • In the Default Gateway field, enter the IP address for the default gateway (router). • Enter your password in the Switch Password field. The password can be from 1 to 25 alphanumeric characters, can start with a number, is case sensitive, allows embedded spaces, but does not allow spaces at the beginning or end. In the Confirm Switch Password field, enter your password again. Note You must change the password from the default password, cisco. Optional Fields You can enter other administrative settings in the Express Setup window. For example, the optional administrative settings identify and synchronize the switch for enhanced management. The switch clock is automatically synchronized with the network clock by using NTP. You can manually set the system clock settings if the switch should have different time settings. Click Submit to save your changes and to complete the initial setup. For more information about the Express Setup fields, see the online help for the Express Setup window. Step 8 After you click Submit, these events occur: • The switch is configured and exits Express Setup mode. • The browser displays a warning message and tries to connect with the earlier switch IP address. Typically, connectivity between the PC and the switch is lost because the configured switch IP address is in a different subnet from the IP address on the PC.
  • 10. Catalyst 2960-S Switch Getting Started Guide 10 Catalyst 2960-S Switch Getting Started Guide OL-19793-02 Step 9 Disconnect the switch from the PC, and install the switch in your network. See the “Rack-Mounting” section on page 18. Step 10 If you changed the static IP address on your PC in Step 2, change it back to the previously configured static IP address. Step 11 You can now manage the switch by using Cisco Network Assistant, Device Manager, or both. See the “Managing the Switch” section on page 11 for information about configuring and managing the switch. We strongly recommend that you download Cisco Network Assistant from Cisco.com and use it to manage the switch. See the “Managing the Switch” section on page 11 for information about configuring and managing the switch. You can display Device Manager by following these steps: 1. Start a web browser on your PC or laptop. 2. Enter the switch IP address, username, and password (assigned in Step 7) in the web browser, and press Enter. The Device Manager page appears. Troubleshooting: If Device Manager does not appear: • Confirm that the port LED for the switch port connected to your network is green. • Confirm that the PC or laptop you are using to access the switch has network connectivity by connecting to a well-known web server in your network. If there is no network connection, troubleshoot the network settings on the PC or laptop. • Make sure that the switch IP address in the browser is correct. • If switch IP address in the browser is correct, the switch interface LED is green, and the PC or laptop has network connectivity, continue troubleshooting by reconnecting the PC or laptop to the switch. Configure a static IP address on the PC or laptop that is in the same subnet as the switch IP address. For example: – If your switch IP address is 172.20.20.85 and your PC or laptop IP address is 172.20.20.84, both devices are in the same network. – If your switch IP address is 172.20.20.85 and your PC or laptop IP address is 10.0.0.2, the devices are in different networks and cannot communicate directly. • When the LED on the switch port connected to the PC or laptop is green, reenter the IP address of the switch in a web browser to display Device Manager. Once Device Manager appears, you can continue with the switch configuration.
  • 11. 11 Catalyst 2960-S Switch Getting Started Guide OL-19793-02 Catalyst 2960-S Switch Getting Started Guide Managing the Switch After completing Express Setup and installing the switch in your network, you can use one of these options for further configuration: • Device Manager • Cisco Network Assistant • Command-Line Interface • Other Management Options Device Manager The simplest way to manage the switch is by using Device Manager in the switch memory. This web interface offers quick configuration and monitoring. You can access Device Manager from anywhere in your network through a web browser. 1. Launch a web browser on your PC or workstation. 2. Enter the switch IP address in the web browser, and press Enter. The Device Manager page appears. 3. Use Device Manager to perform basic switch configuration and monitoring. See the Device Manager online help for more information. 4. For more advanced configuration, download and run Cisco Network Assistant, which is described in the next section. Cisco Network Assistant Cisco Network Assistant is a software program that you download from Cisco.com and run on your PC. It offers advanced options for configuring and monitoring multiple devices, including switches, switch clusters, switch stacks, routers, and access points. Cisco Network Assistant is free—there is no charge to download, install, or use it. 1. Go to this Web address: http://www.cisco.com/en/US/products/ps5931/tsd_products_support_series_ home.html.
  • 12. Catalyst 2960-S Switch Getting Started Guide 12 Catalyst 2960-S Switch Getting Started Guide OL-19793-02 You must be a registered Cisco.com user, but you need no other access privileges. 2. Find the Network Assistant installer. 3. Download the Network Assistant installer and run it. (You can run it directly from the Web if your browser offers this choice.) 4. When you run the installer, follow the displayed instructions. In the final panel, click Finish to complete the Network Assistant installation. See the Network Assistant online help and the getting started guide for more information. Command-Line Interface You can enter Cisco IOS commands and parameters through the CLI. Access the CLI by using one of these options: • Switch Console Port • Switch Ethernet Management Port • Switch USB Port
  • 13. 13 Catalyst 2960-S Switch Getting Started Guide OL-19793-02 Catalyst 2960-S Switch Getting Started Guide Switch Console Port 1. Connect the supplied RJ-45-to-DB-9 adapter cable to the standard 9-pin serial port on the PC. Connect the other end of the cable to the console port on the switch. 2. Start a terminal-emulation program on the PC. 3. Configure the PC terminal emulation software for 9600 baud, 8 data bits, no parity, 1 stop bit, and no flow control. 4. Use the CLI to enter commands to configure the switch. See the software configuration guide and the command reference for more information. Switch Ethernet Management Port 1. Connect a Category 5 Ethernet cable to the PC Ethernet port. Connect the other end of the cable to the Ethernet management port on the switch. 2. Start a Telnet session on the PC. 3. Enter the switch IP address that you assigned by using Express Setup. 4. Use the CLI to enter commands to configure the switch. See the software configuration guide and the command reference for more information. Switch USB Port 1. Connect an USB cable to the PC USB port. Connect the other end of the cable to the mini B (5-pin-connector) USB port on the switch. 2. Start a terminal-emulation program on the PC. 3. Configure the PC terminal emulation software for 9600 baud, 8 data bits, no parity, 1 stop bit, and no flow control. 4. Use the CLI to enter commands to configure the switch. See the software configuration guide and the command reference for more information. Note You cannot use the switch console port and the switch USB port at the same time to access the CLI.
  • 14. Catalyst 2960-S Switch Getting Started Guide 14 Catalyst 2960-S Switch Getting Started Guide OL-19793-02 Other Management Options You can use SNMP management applications such as CiscoWorks LAN Management Solution (LMS) and Cisco netManager to configure and manage the switch. You also can manage it from an SNMP-compatible workstation that is running platforms such as Cisco netManager or SunNet Manager. The Cisco Configuration Engine is a network management device that works with embedded Cisco Networking Services (CNS) agents in the switch software. You can use it to automate initial configurations and configuration updates on the switch. See the “Accessing Help Online” section on page 28 for a list of supporting documentation. Planning and Creating Switch Stacks Note This section applies only to the Catalyst 2960-S stacking switches. Before connecting the switches in a stack, keep in mind these switch stack guidelines: • Connect only Catalyst 2960-S switches in a switch stack. • Install the FlexStack module and the FlexStack cable for stacking capability. You can order them in a kit from your Cisco sales representative: C2960S-STACK=. • Consider the length of FlexStack cable. Depending on your configurations, you might need different sized cables. You can order them from your Cisco sales representative: – CAB-STK-E-0.5M= (0.5-meter cable) – CAB-STK-E-1M= (1-meter cable) – CAB-STK-E-3M= (3-meter cable) For additional stacking guidelines, see the switch hardware installation guide on Cisco.com. For concepts and procedures to manage switch stacks, see the switch software configuration guide on Cisco.com.
  • 15. 15 Catalyst 2960-S Switch Getting Started Guide OL-19793-02 Catalyst 2960-S Switch Getting Started Guide Installing the FlexStack Module Step 1 Use a flat-blade screwdriver to remove the FlexStack module blank cover on the switch back panel. Step 2 Grasp the FlexStack module on the sides, and insert it into the module slot. Step 3 Secure the screws tightly on each side of the module. Note Make sure the screws are finger-tight to avoid overtightening of the screws. 206255 206232 RATING 100-240~ 12-6A, 50-60Hz RATING 100-240~ 12-6A, 50-60Hz 206239
  • 16. Catalyst 2960-S Switch Getting Started Guide 16 Catalyst 2960-S Switch Getting Started Guide OL-19793-02 Cabling Guidelines These illustrations show the recommended switch stack configurations with redundant stack cabling connections for optimized stack bandwidth. For more configuration examples, see the hardware installation guide on Cisco.com. This is an example of a redundant stack cable connection using the 0.5-meter FlexStack cable. 206231
  • 17. 17 Catalyst 2960-S Switch Getting Started Guide OL-19793-02 Catalyst 2960-S Switch Getting Started Guide This is an example of a redundant stack cable connection using both the 0.5- and 3-meter FlexStack cables. Powering Guidelines Consider these guidelines before you power the switches in a stack: • If you want a particular switch to become the stack master, power on that switch first. This switch becomes the stack master and remains the stack master until a master reelection is required. After 2 minutes, power on the remaining switches in the stack. • Power off a switch before you add it to or remove it from an existing switch stack. For more information on stack master elections, see the “Managing Switch Stacks” chapter in the switch software configuration guide on Cisco.com. 206230
  • 18. Catalyst 2960-S Switch Getting Started Guide 18 Catalyst 2960-S Switch Getting Started Guide OL-19793-02 Rack-Mounting This section covers basic 19-inch rack-mounting and switch port connections. As an example, all the illustrations show the Catalyst 2960S-48FPD-L switch. You can install and connect the other Catalyst 2960-S switches as shown in these illustrations. For alternate mounting procedures, such as installing the switch in a 24-inch rack or on a wall, and for additional cabling information, see the hardware installation guide on Cisco.com. Required Tools You need to supply a number-2 Phillips screwdriver to rack-mount the switch. Before You Begin Before installing the switch, verify that these guidelines are met: • Clearance to the front panels is sufficient so that the LEDs can be easily read. • Access to the switch rear panel to connect the optional Cisco Redundant Power Supply (RPS) 2300 or to stack the switches. If you do not have access to the rear panel, you should cable the switches before you rack-mount them. • AC power cord reaches from the AC power outlet to the connector on the switch rear panel. • Cabling is away from sources of electrical noise, such as radios, power lines, and fluorescent lighting fixtures. Make sure the cabling is safely away from other devices that might damage the cables. • Airflow around the switch and through the vents is unrestricted. • Temperature around the unit does not exceed 113°F (45°C). If the switch is installed in a closed or multirack assembly, the temperature around it might be greater than normal room temperature. • Humidity around the switch does not exceed 85 percent. • Altitude at the installation site is not greater than 10,000 feet.
  • 19. 19 Catalyst 2960-S Switch Getting Started Guide OL-19793-02 Catalyst 2960-S Switch Getting Started Guide • For 10/100 or 10/100/1000 fixed ports, cable lengths from the switch to connected devices can be up to 328 feet (100 meters). • For cable lengths for small form-factor pluggable (SFP)-module connections, see the hardware installation guide on Cisco.com and the documentation that shipped with the module. Installation Warning Statements This section includes the basic installation warning statements. Translations of these warning statements appear in the Regulatory Compliance and Safety Information for the Catalyst 2960 and 2960-S Switches document on Cisco.com. Warning To prevent bodily injury when mounting or servicing this unit in a rack, you must take special precautions to ensure that the system remains stable. The following guidelines are provided to ensure your safety: This unit should be mounted at the bottom of the rack if it is the only unit in the rack. When mounting this unit in a partially filled rack, load the rack from the bottom to the top with the heaviest component at the bottom of the rack. If the rack is provided with stabilizing devices, install the stabilizers before mounting or servicing the unit in the rack. Statement 1006 Warning Class 1 laser product. Statement 1008 Warning This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available. Statement 1024
  • 20. Catalyst 2960-S Switch Getting Started Guide 20 Catalyst 2960-S Switch Getting Started Guide OL-19793-02 Warning To prevent the system from overheating, do not operate it in an area that exceeds the maximum recommended ambient temperature of: <113°F (45°C). Statement 1047 Warning To prevent airflow restriction, allow clearance around the ventilation openings to be at least: 3 inches (7.6 cm). Statement 1076 Before Attaching Brackets To install the switch in a rack, you must first remove the screws from the switch chassis so that the mounting brackets can be attached. Note You do not need to remove the screws for attaching the brackets in the rear-mounting position. 252587 39X 38X 47X 48X 1 2 Catalyst 2960-S Series PoE+ 10G
  • 21. 21 Catalyst 2960-S Switch Getting Started Guide OL-19793-02 Catalyst 2960-S Switch Getting Started Guide Attaching the Brackets Use four Phillips flat-head screws to attach the long side of the brackets to Catalyst 2960-S switches in one of three mounting positions. 1 Front-mounting position 3 Mid-mounting position 2 Number-8 Phillips flat-head screws (48-0655-01) 4 Rear-mounting position POWER OVER ETHERN ET 740W 11X 2X 1X 11X 14X12X 13X 23X 24X 25X 26X 37X 39X 36X 38X 47X 48X 1 2 Catalyst 2960-S Series PoE+ 10G Catalyst 2960-S Series PoE+ 10G RATING 100-240~12-6A, 50-60Hz 11X 2X 1X 11X 14X12X 13X 23X 24X 25X 26X 37X 39X 36X 38X 47X 48X 1 2 POWER OVER ETHERN ET 740W Catalyst 2960-S Series PoE+ 10G 206599 2 1 3 4
  • 22. Catalyst 2960-S Switch Getting Started Guide 22 Catalyst 2960-S Switch Getting Started Guide OL-19793-02 Rack-Mount the Switch Use the four number-12 Phillips machine screws to attach the brackets to the rack. Use the black Phillips machine screw to attach the cable guide to the left or right bracket. . 1 Cable guide 4 Number-12 Phillips pan-head screws (48-0523-01) 2 Black Phillips machine screw (48-0654-01) 5 Mid-mounting position 3 Front-mounting position 6 Rear-mounting position 11X 2X 1X 11X 14X12X 13X 23X 24X 25X 26X 37X 39X 36X 38X 47X 48X 1 2 11X 2X 1X 11X 14X12X 13X 23X 24X 25X 26X 37X 39X 36X 38X 47X 48X 1 2 POWER OVER ETHERN ET 740W POWER OVER ETHERN ET 740W Catalyst 2960-S Series PoE+ 10G Catalyst 2960-S Series PoE+ 10G 1 2 206600 RATING 100-240~ 12-6A, 50-60Hz 3 4 5 6
  • 23. 23 Catalyst 2960-S Switch Getting Started Guide OL-19793-02 Catalyst 2960-S Switch Getting Started Guide Connecting the FlexStack Cables Always use a Cisco-approved FlexStack cable to connect the switches. Connect only Catalyst 2960-S switches in a switch stack. Step 1 Remove the dust covers from the FlexStack cables, and store them for future use. Step 2 Insert one end of the FlexStack cable into the stack port of the first switch. Insert the other end of the cable into the stack port on the other switch. Note When you connect the FlexStack cable into the STACK 1 port, the tab should be above the connector. When you connect the FlexStack cable into the STACK 2 port, you should invert the cable so that the tab is below the connector. Step 3 Replace the dust covers when you remove the FlexStack cables from the connectors. Removing and installing the FlexStack cable can shorten its useful life. Do not remove and insert the cable more often than is absolutely necessary. 206235
  • 24. Catalyst 2960-S Switch Getting Started Guide 24 Catalyst 2960-S Switch Getting Started Guide OL-19793-02 Connecting to the Switch Ports This section describes how to connect to the fixed switch ports and to the SFP module ports. Connect to the 10/100 or 10/100/1000 Ports The fixed ports on the Catalyst 2960-S Power over Ethernet Plus (PoE+) switches provide: • PoE+ support for IEEE 802.3at-compliant powered devices • PoE support for IEEE 802.3af-compliant powered devices • Support for Cisco enhanced PoE (ePoE) They also provide Cisco prestandard PoE support for Cisco IP phones and Cisco Aironet Access Points. See the switch hardware guide for information on PoE budgeting. By default, a Catalyst 2960-S switch PoE port automatically provides power when a compliant device is connected, including ePoE, PoE, and PoE+. For information about configuring and monitoring PoE and PoE+ ports, see the switch software configuration guide. Step 1 When you connect to servers, workstations, IP phones, wireless access points, and routers, insert a straight-through, twisted four-pair, Category 5 cable in a switch 10/100 or 10/100/1000 port. Use a crossover, twisted four-pair, Category 5 cable when you connect to other switches, hubs, or repeaters. Step 2 Insert the other cable end into an RJ-45 port on the other device. 11X 14X12X 1X 2X 11X POWER OVER ETHERNET 740W 206236
  • 25. 25 Catalyst 2960-S Switch Getting Started Guide OL-19793-02 Catalyst 2960-S Switch Getting Started Guide Note The automatic medium-dependent interface crossover (auto-MDIX) feature is enabled by default. The switch detects the required cable type for copper Ethernet connections and configures the interfaces accordingly. Therefore, you can use either a crossover or a straight-through cable for connections to a copper 10/100 or 10/100/1000 module port on the switch, regardless of the type of device on the other end of the connection. Install the SFP or SFP+ Modules Some Catalyst 2960-S switches have SFP module slots and others have SFP+ module slots. The SFP slots support only the SFP modules. The SFP+ slots support both SFP and SFP+ modules. For a list of supported modules, see the release notes on Cisco.com. For detailed instructions on installing, removing, and connecting to SFP modules, see the documentation that came with the SFP module. Caution Removing and installing an SFP module can shorten its useful life. Do not remove and insert SFP modules more often than is absolutely necessary. Step 1 Grasp the module on the sides, and insert it into the switch slot until you feel the connector snap into place. Step 2 Insert an appropriate cable into the module port. Insert the other cable end into the other device. 47X 48X 1 2 Catalyst 2960-S Series PoE+ 10G 206237 47X 48X 1 2 Catalyst 2960-S Series PoE+ 10G
  • 26. Catalyst 2960-S Switch Getting Started Guide 26 Catalyst 2960-S Switch Getting Started Guide OL-19793-02 Verify Port Connectivity After you connect the switch port and another device, the port LED turns amber while the switch establishes a link. This process takes about 30 seconds, and then the LED turns green. If the LED turns off, the target device might not be turned on, there might be a cable problem, or there might be a problem with the adapter installed in the target device. See the “In Case of Difficulty” section on page 26 for information about online assistance. In Case of Difficulty If you experience difficulty, help is available in this section and also on Cisco.com. This section includes Express Setup troubleshooting, how to reset the switch, how to access help online, and where to find more information. Troubleshooting Express Setup If Express Setup does not run, or if the Express Setup page does not appear in your browser: Did you verify that POST ran successfully before starting Express Setup? If not, make sure that only the SYST and STAT LEDs are green before you press the Mode button to enter the Express Setup mode. POST errors are usually fatal. Contact your Cisco technical support representative if your switch fails POST. Did you press the Mode button while the switch was still running POST? If yes, wait until POST completes. Power cycle the switch. Wait until POST completes. Confirm that the SYST and STAT LEDs are green. Press the Mode button to enter Express Setup mode.
  • 27. 27 Catalyst 2960-S Switch Getting Started Guide OL-19793-02 Catalyst 2960-S Switch Getting Started Guide Did you try to continue without confirming that the switch was in Express Setup mode? Verify that all LEDs above the Mode button are green. (The RPS LED is off.) If necessary, press the Mode button to enter Express Setup mode. Does your PC have a static IP address? If yes, before connecting to the switch, change your PC settings to temporarily use DHCP. Did you connect a crossover cable instead of a straight-through Ethernet cable between a switch port and the Ethernet port of the PC? If yes, connect a straight-through cable to an Ethernet port on the switch and the PC. Wait 30 seconds before you enter 10.0.0.1 in the browser. Did you connect the Ethernet cable to the console port instead of to a 10/100 or 10/100/1000 Ethernet port on the switch? If yes, disconnect the cable from the console port. Then connect the cable to an Ethernet port on the switch and the PC. Wait 30 seconds before you enter 10.0.0.1 in the browser. Note The console port is outlined in blue, and the Ethernet port is outlined in yellow. Did you wait 30 seconds after you connected the switch and the PC before you entered the IP address in your browser? If not, wait 30 seconds, re-enter 10.0.0.1 in the browser, and press Enter. Did you enter the wrong address in the browser, or is there an error message? If yes, re-enter 10.0.0.1 in the browser, and press Enter.
  • 28. Catalyst 2960-S Switch Getting Started Guide 28 Catalyst 2960-S Switch Getting Started Guide OL-19793-02 Resetting the Switch Follow these steps to return your switch to the factory default settings. These are reasons why you might want to reset the switch: • You installed the switch in your network and cannot connect to it because you assigned the wrong IP address. • You want to clear all configurations from the switch and assign a new IP address. • You want to reset the password on the switch. Caution Resetting the switch deletes the configuration and reboots the switch. To reset the switch: Press and hold the Mode button. The switch LEDs begin blinking after about 3 seconds. Continue holding down the Mode button. The LEDs stop blinking after 7 more seconds, and then the switch reboots. The switch now behaves like an unconfigured switch. You can enter the switch IP information by using Express Setup as described in the “Running Express Setup” section on page 4. Accessing Help Online First look for a solution to your problem in the troubleshooting section of the switch hardware installation guide or the switch software configuration guide on Cisco.com. You can also access the Cisco Technical Support and Documentation website for a list of known hardware problems and extensive troubleshooting documentation.
  • 29. 29 Catalyst 2960-S Switch Getting Started Guide OL-19793-02 Catalyst 2960-S Switch Getting Started Guide For More Information For more information about the switch, see these documents on Cisco.com: • Catalyst 2960-S Switch Hardware Installation Guide • Regulatory Compliance and Safety Information for the Catalyst 2960 and 2960-S Switches • Release Notes for the Catalyst 2960-S Switch • Catalyst 2960 and 2960-S Switch Software Configuration Guide • Catalyst 2960 and 2960-S Switch Command Reference • Catalyst 3750, 3560, 2975, 2960, and 2960-S Switch System Message Guide • Device Manager online help (available on the switch) • Cisco Small Form-Factor Pluggable Modules Installation Notes Obtaining Documentation and Submitting a Service Request For information on obtaining documentation, submitting a service request, and gathering additional information, see the monthly What’s New in Cisco Product Documentation, which also lists all new and revised Cisco technical documentation, at: http://www.cisco.com/en/US/docs/general/whatsnew/whatsnew.html Subscribe to the What’s New in Cisco Product Documentation as a Really Simple Syndication (RSS) feed and set content to be delivered directly to your desktop using a reader application. The RSS feeds are a free service and Cisco currently supports RSS version 2.0. Cisco and the Cisco logo are trademarks or registered trademarks of Cisco and/or its affiliates in the U.S. and other countries. To view a list of Cisco trademarks, go to this URL: www.cisco.com/go/trademarks. Third-party trademarks mentioned are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company. (1110R) Any Internet Protocol (IP) addresses used in this document are not intended to be actual addresses. Any examples, command display output, and figures included in the document are shown for illustrative purposes only. Any use of actual IP addresses in illustrative content is unintentional and coincidental. © 2010-2012 Cisco Systems, Inc. All rights reserved.
  • 30. Catalyst 2960-S Switch Getting Started Guide 30 Catalyst 2960-S Switch Getting Started Guide OL-19793-02