FULL ENJOY - 9953040155 Call Girls in Chhatarpur | Delhi
C 9201ex
1. Explosion Proof
Manual Call Point
C-9201Ex
Technical Specifications
•
•
•
•
•
•
Features and Benefits
1.
2.
3.
4.
LED indicator
Two plug-in constructions allow easy
installation.
Utilized independent output contact
Initiated by fire alarm point using
I-9332Ex Interface
Description
C-9201(Ex) Explosion Proof Manual Call Point
is designed for the purpose of raising an
alarm manually once verification of a fire or
emergency condition exists, by pressing the
non breakable glass and alarm signal can be
sent to the controller. After receiving the
alarm signal, the controller will show the
number of LD-8332 Interface connecting with
the MCP, and vocalize alarm sound. This MCP
is intrinsically safe type, is suitable in
inflammable and hazardous places in
petroleum and chemical industries.
•
•
•
•
•
•
•
•
Operating Voltage: 24Vdc
Operating Current:
Standby Current: 0mA
Alarming Current≤30mA
Output Capacity: Rating DC60V/100mA
passive output contact signal, contact
resistance≤100mΩ
Type of Initiating Part: Reusable
Reset Mode: Manually resuming by a
sucker
LED indicator: Red, not lit when normal,
lit after alarming.
Explosion-proof Marking: ExibIICT6
Safety Barrier Output Parameters:
Uo+28V, Io=93mA
Wiring: 1 Pair
Operating Environment:
Temperature: -10ºC+50 ºC
Relative
Humidity:
≤95%,
no
condensation
Mounting Hole Distance: 65mm
Dimension: 90mm×122mm×48.5mm
Degree of Protection of Enclosure: IP40
Material and Colour: ABS, red
Call Point Installation
The MCP should be installed complied with all
local codes or NFPA 72 National Fire Alarm Code,
NFPA 70 National Electrical Code, BS5839,
EN54.It is installed onto a standard one gang
electrical box with a mounting hole that have
6.5cm spacing.
65
2. Explosion Proof
Manual Call Point
C-9201Ex
Wiring and Connection
Safety Area
Hazardous Area
K1 K2
O2
I-9332 Interface
Explosion-proof
Detector
Explosion-proof
Detector
O1 I1
Terminal Resistor
I2
Explosion-proof
Manual Call Point
Explosion-proof
Detector
Sample wiring diagram above show manual call point connected with I-9333 Interface. The
terminals I1, I2: to intrinsically safe side of the Safety Barrier.; K1, K2: Normally open output terminals; while O2,
O1: To next MCP.
Selection of compatible Control Panels
Compatible with all GST Intelligent Fire Alarm Panels via I-9332Ex Explosion Proof Interface
(purchased separately)
Ordering Information:
Part No
C-9201Ex
I-9332
Description
Explosion Proof and Intrinsically Safe
Conventional Manual Call Point
Interface Module
Weight/Kg
Pack Qty per
Box
0.221
120
1.5Kg
1
MANUFACTURED IN ACCORDANCE WITH
Note: Specifications are subject to change without notice.