Welding Cable Selection Guide by Technocrats Plasma Systems Private Limited - Manufacturer, Supplier & Exporter of Plasma Cutting & Welding Machine in India Since 1990.
2. Welding cables- the current carrier between machine
and the job.
Welding cable size selection- an important but
commonly unknown knowledge; often ignored by
users as well as manufacturers.
Insufficient cable size- the cause of unsatisfactory
performance many a times which goes unnoticed;
ultimately service dept. and goodwill of the company
suffers.
3. Q. Standard length of cables used for commercial
welding e.g. Maintenance workers, fabricators etc. ?
3-5 meters.
Q. What conductor material should ideally be used?
Copper
Q. Range of cable length in heavy industrial
applications e.g. Tube mill, ship yards etc. ?
15-50 meters.
4. Welding cables are affected by various factors which
cause power losses during welding.
Power dissipation factors:
1. Length of cable.
2.Cross- sectional Area of cable.
3. Resistance of the material.
4.Ambient temperature.
5. Consider Solaris 400:
o/p current(I)= 300 amps
Arc voltage(V)= 32 volts
Arc voltage = 20+(0.04*I)
o/p power(P) = V x I= 9.6kW
This is the o/p power when welding with short cables
up to distances of 5 meters.
6. Now,
What about o/p power when welding cables used are of
lengths ranging up to 50 meters?
Power dissipation along cable length.
Dissipated power = I2
x R
Resistance(R) = ρL / A
ρ= 1.68 x10-8
Ωm for copper and 2.65 x10-8
Ωm for aluminum.
7. Suppose the length of welding cable is 30 meters.
R= ρL / A (A= 95 mm2
)
= 1.68 x10-8
Ωm x30m / 95x10-6
m2
.
=5.3052 mΩ.
R= ρL / A (A= 35 mm2
)
= 1.68 x10-8
Ωm x30m / 35x10-6
m2
.
=14.4 mΩ
Dissipated power along cable of area 95 mm2
= I2
x R
= 3002
x 5.3052m
= 477.468 W
Dissipated power along cable of area 35 mm2
= I2
x R
= 3002
x 14.4m
= 1.296 kW
8. Total Power At Job End = O/P at terminal –
Power dissipated along the
cable.
When cable area -95 mm2
= 9.6 kW – 477.468 W
= 9.1 kW
When cable area -35 mm2
= 9.6 kW – 1.296 kW
= 8.304 kW
*All calculations are considering copper cables & an
ambient temperature of 20˚C.
Hence, to reduce power losses, the diameter/cross
sectional area of cable should increase as cable length
increases.
10. COMMON INDUSTRIAL PRACTICE
The case study was considering both +ve & -ve cables
to be of 30 mtr. Length.
Now, as per common industrial practice, the job cable
is replaced by common strips, kept one on top of the
other.
This leads to a huge voltage drop at the contact point
as the contact area is very small, leading to sparks
during welding.
This drop causes further power losses.
11. o/p power=9.6 kW
Length= 30 mts.
Area= 35 mm2
Work Piece
Electrode
holder
rod
Power << 8.304 kW
Job clamp
Common strips
13. The first preference of any user when purchasing an
inverter machine is the low power consumption of
this technology.
The excess power losses in the cables(around 1 kW)
increase the machine’s power losses, making the low
power consumption plus point ineffective.
Advice our valued customers to save power by
making the right choice.