SlideShare a Scribd company logo
1 of 111
Download to read offline
Samples of Conceptual Design
WARBY PARKER: 1258 6TH AVE ROCKEFELLER CENTER
Design Progress – 21 July 2017
“
“
Radio City Music Hall was to be a palace for
the people. A place of beauty offering high-quality
entertainment at prices ordinary people could afford.
WARBY PARKER
Direction I + II - Ground Floor Plan
Customer	
Elevator
OPEN BACK FIXTURE AT
STREET FACING WINDOW
BRASS INL AY COVERED WINDOW
(ACCESSIBLE)
WOOD STAIRS TO
SECOND FLOOR
ACCESSIBLE STORAGE18 PRODUCT BAYS
(GCT:18 PRODUCT BAYS)
5
Direction I - Ceiling Plan
WARBY PARKER
PAINTED DRYWALL DOME.
(NOTE: DOME COVERS 50TH
STREET FACING WINDOWS)
BLUE L ACQUERED
PANELS WITH (6)
RECESSED FIXTURES
6
This ceiling plan will updated to a simpler configuration
WARBY PARKER
Direction I + II - Second Floor Plan
EXAM ROOM 2 EXAM ROOM 1 PRE-TESTING
ROOM
BENCH SEATING AND
TABLES (MODUL AR)
CUSTOMER LOUNGE
CUSTOMER LOUNGE
(CHEVRON OPTION)
FULL HEIGHT
PARTITION
7
We are reviewing additional floor finish options
Rockefeller Center
Direction I + II - Third Floor Plan
WARBY PARKER
TRAINING ROOM
MANAGERS OFFICE
OPS COUNTER
LVT FLOORING
THROUGHOUT BOH
8
Direction I - Elevation
WARBY PARKER
WHITE L ACQUER LIBRARY
PRODUCT BAYS WITH
LIGHT OAK INTERIOR.
WHITE STAINED OAK
PANELING AT REF DESK.
OPEN BACK AT
WINDOW.
WHITE STAINED OAK PANELING
AT ELEV. SURROUND
COLOR BLOCKING
WINDOW TREATMENTS
9
Direction I - Elevation
WARBY PARKER
STORAGE
PARTIALLY OPEN
PRE-TESTING ROOM.
TO EXAM ROOM
(PL ACEHOLDER ARTWORK)
PL ACEHOLDER ARTWORK AT
EYE EXAM ROOMS WALLS
WHITE STAINED OAK
PANELING AT REF DESK.
10
Direction I - Ref Desk Elevation
WARBY PARKER
WALNUT BENCH PL ACEHOLDER REF DESK, FRAMED
ARTWORK AND EYE EXAM SIGNAGE
11
Direction I - Store Section View I
WARBY PARKER12
Direction I - Store View II
WARBY PARKER
25July 21, 2017
13
WARBY PARKER14
SALES FLOOR - MODUL AR TABLES
(SHOWN WITHOUT BENCH AT ROCK CENTER)
Direction I - Sales Tables
WARBY PARKER41
FF&E - Bench
SECOND FLOOR WINDOW BENCH
(UPHOLSTERY TBC; TIE INTO PRODUCT LEATHER)
October 16, 2017
UNION STATION
Storefront Elevation
9	¼”	Hanging	unlit	signage	
New	180	degree
swing	doors
Mall	standard	finishes
Mall	standard	blade	sign
Mall	Storefront	Metal
October 16, 2017
UNION STATION
Interior Wall Elevations
Customer	
seating	near	
exam	room
CPU
TERMINAL	
CONCOURSE
TERMINAL	
CONCOURSE
BOH
EXAM	
ROOM
Warby Custom	‘Reading	
Positions’	Wallcovering
October 16, 2017
UNION STATION
Colors and Materials
General	Paint- Oxford	White
Ceiling	Panel- Old	Pick	Up	Truck	Blue	Option
Grigio Tucci Marble
Reference	Desk- Gray
Metal	Detail- Brushed	Brass
Library	Cabinet- Clear	Rift	Oak
Selling	Table- Walnut
Leather
Flooring- White	Terrazzo
Flooring- Grey	Terrazzo
Samples of Retail
Construction Documents
COVER SHEET
40 MASSACHUSETTS AVE. NE
WASHINGTON DC 20002
SUITE: 112
P-1
SUITE: 112
40 MASSACHUSETTS AVE. NE
WASHINGTON DC 20002
40 MASSACHUSETTS AVE. NE
WASHINGTON DC 20002
SUITE: 112
SPECIFICATIONS
40 MASSACHUSETTS AVE. NE
WASHINGTON DC 20002
SUITE: 112
SPECIFICATIONS
40 MASSACHUSETTS AVE. NE
WASHINGTON DC 20002
SUITE: 112
COMPUTER DIE-CUT VINYL
DIRECT VIEW FOR OPAQUE
SURFACES. REVERSE VIEW
FOR APPLICATION ON
SURFACE OF TRANSPARENT
SURFACES. COLOR:
INTERNATIONAL BLUE
LC
CL
FIELD WITH TEXT AND
GRADE 2 BRAILLE OF
ABOVE TEXT
5/8" HIGH MIN. TYPE
RAISED 1/32" MIN.
HELVETICA MEDIUM
UPPERCASE LETTERS
LC
TACTILE EXIT SIGNAGE
FIELD WITH TEXT AND
GRADE 2 BRAILLE OF
ABOVE TEXT
5/8" HIGH MIN. TYPE
RAISED 1/32" MIN.
HELVETICA MEDIUM
UPPERCASE LETTERS
LC
TACTILE EXIT SIGNAGE
CL
LC
LC
SIDE
VIEW
12" TYP.
12" TYP.
SIDE
VIEW
SIGN
SIGN
CL
1/4"
THICK
60"AF.F.
FLOOR,TYP.
1/4"
THICK
OF TOILET ENTRY
DOORS, TYP.
60"AF.F.
FLOOR,TYP.
60"AF.F.
FLOOR,TYP.
FIELD WITH
SYMBOLS
60"AF.F.
FLOOR,TYP.
FIELD WITH
SYMBOLS
5/8" HIGH MIN.
TYPE RAISED
1/32" MIN.
HELVETICA
MEDIUM
UPPERCASE
LETTERS
FIELD WITH TEXT
AND GRADE 2
BRAILLE OF
ABOVE TEXT
60"AF.F.
FLOOR,TYP.
60"AF.F.
FLOOR,TYP.
E F
WHEN PERMANENT IDENTIFICATION IS PROVIDED FOR ROOMS
AND SPACES, RAISED LETTERS SHALL BE PROVIDED AND SHALL BE
ACCOMPANIED BY BRAILLE IN CONFORMANCE WITH SECTION
4.30.4 OF THE ADA. SIGNS SHALL BE INSTALLED ON THE WALL
ADJACENT TO THE LATCH OUTSIDE OF THE DOOR. WHERE THERE IS
NO WALL SPACE ON THE LATCH SIDE, INCLUDING AT DOUBLE LEAF
DOORS, SIGNS SHALL BE PLACED ON THE NEAREST ADJACENT
WALL, PREFERABLY ON THE RIGHT. MOUNTING HEIGHT SHALL BE
60" ABOVE THE FINISHED FLOOR TO THE CENTERLINE OF THE SIGN.
MOUNTING LOCATION SHALL BE DETERMINED SO THAT A PERSON
MAY APPROACH WITHIN 3" OF SIGNAGE WITHOUT
ENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN
THE SWING OF A DOOR. SEC. 4.30.6 OF THE ADA.
SIGNS & IDENTIFICATION:
ENTIRE FACILITY SHALL CONFORM TO THE MINIMUM REQUIREMENT
OF THE AMERICAN WITH DISABILITY ACT (ADA), ACCESSIBILITY
STANDINGS AND ALL LOCAL GOVERNING REGULATIONS.
5/8" HIGH MIN.
TYPE RAISED
1/32" MIN.
HELVETICA
MEDIUM
UPPERCASE
LETTERS
FIELD WITH TEXT
AND GRADE 2
BRAILLE OF
ABOVE TEXT
60"MIN
18" MIN
48"MIN.
12" MIN.
60"MIN.
36"
42"MIN.
54" MIN.
48"MIN.
24"
48"MIN.
42"MIN.
Y
24" MIN.
24" (610 mm)
PREFERRED
32" MIN.
24"
MAX.
48"MIN.
48"MIN.
60" DIA.
36"
60"
24"
12"
36"
48"
48"
48"
X
Z
Y
X
30"
30"
15"MIN.
32-42"PREFERRED
48"MAX.
HIGH FORWARD REACH LIMIT
MAXIMUM FORWARD REACH
OVER AN OBSTRUCTION
NOTE
Z SHALL BE X, WHEN X20 IN., THEN Y SHALL BE
48 IN. MAXIMUM. WHEN X IS 20 TO 25 IN., THEN
Y SHALL BE 44 IN. MAXIMUM.
18"MIN.
1 1
4" - 2"Ø
1 1
2" MIN.
1-1/2"
MIN.
1 1
2" MIN.
1 1
2" MIN.
1 1
4" - 2"Ø
1-1/4" TO 1-1/2"
60" MIN.
56"MIN.
42"
MIN.
18"
MIN
36" 6"
33-36"
39"-41"18"
18"
CL24"
MIN
6" MAX.
TOE CLEARANCE
8" MIN. KNEE
CLEARANCE
9" MIN.
34"MAX.
27"MIN.
17" MIN. DEPTH
29"MIN
CLEARANCE AT DRINKING FOUNTAIN
10
17 - 19" EQUIPMENT
PERMITTED IN
SHADED AREA
8" MIN.
6" MIN.
9" MIN.
36"
29"
17 - 19"
24"
48"
MIN.
36" MIN.
60" MIN.
32" MIN.
2'-0"
48" MIN.
48"
30"10"
MAX.
SLOPE SHALL NOT EXCEED 1:48
CLEARANCE AT LAVATORY9
48"MIN.
30" MIN.
19"
MAX.
17"MIN.
CLEAR FLOOR
SPACE
8" MIN CL
33"
19"
(MIN.)
17"-19"
12" 42"
12"
MAX
39"-41" MIN.
39"-41"18"
CL
54" MIN
36"
MAX
HAND RAIL/GRAB BAR7
FORWARD REACH RANGES
5
SIDE REACH RANGES
6
TURNING SPACE
4
MIN. FLOOR WIDTH CLEARANCE
3
DOOR IN SERIES
2
DOOR CLEARANCES1
SHELVES
CLOSET
21" MAX.
48"MAX.48"MAX.
21" MAX.9" MIN.
30"24"
34"MAX.
46"
30"
10"
MAX.
32-42"PREFERRED
15"MIN.
48"MAX.
UNOBSTRUCTED REACH
18"CL 28"
MIN
18"
MIN
CL
12"MAX
54"MIN
24"
MIN
48"MIN
60" MIN
DIA
CLEAR
18"
MIN
TACTILE EXIT SIGNAGE
FIELD WITH TEXT AND
GRADE 2 BRAILLE OF
ABOVE TEXT
5/8" HIGH MIN. TYPE
RAISED 1/32" MIN.
HELVETICA MEDIUM
UPPERCASE LETTERS
LC
LC
FIELD WITH
SYMBOLS
60"AF.F.
FLOOR,TYP.
60"AF.F.
FLOOR,TYP.
D
5/8" HIGH MIN.
TYPE RAISED
1/32" MIN.
HELVETICA
MEDIUM
UPPERCASE
LETTERS
FIELD WITH TEXT
AND GRADE 2
BRAILLE OF
ABOVE TEXT
LC
CL
SEE
12" TYP.
12"TYP.
SIDE
VIEW
SIGN
SEE
1/4"
THICK
60"AF.F.
FLOOR,TYP.
5B
5A
GENERAL ACCESSIBILITY GUIDELINES
CLEAR FLOOR SPACE @ WATER CLOSET8A
TYPICAL SIGN REQUIREMENTS & NOTES TYPICAL DIMENSION INFORMATION
SINGLE ACCOMADATION TOILET FACILITY8
40 MASSACHUSETTS AVE. NE
WASHINGTON DC 20002
SUITE: 112
DEMOLITION PLAN
AND NOTES
40 MASSACHUSETTS AVE. NE
WASHINGTON DC 20002
SUITE: 112
1
D1.0
BREAK COUNTER
ULINE
ULINE
FIXTURE PLAN, FIXTURE
SCHEDULE AND NOTES
40 MASSACHUSETTS AVE. NE
WASHINGTON DC 20002
SUITE: 112
1
F1.0
CONSTRUCTION PLAN,
WALL TYPES, AND NOTES
P-1
40 MASSACHUSETTS AVE. NE
WASHINGTON DC 20002
SUITE: 112
1
A1.0
2
A1.0
LVTCERAMIC TILE
ALIGN FLOOR
FINISH CHANGE
W/SIDE OF DOOR
JAMB
DOOR AND JAMB
ZERO BRASS SADDLE
MODEL:#164B OR
EQUAL
SEALANT JOINT
CERAMIC TO LVT
TERRAZZO TILE
LVT
TERRAZZO TO LVT
TERRAZZO TILE
ON MORTAR
SETTING BED
CERAMIC
TERRAZZO TILE TO CERAMIC
TERRAZZO TILE
ON MORTAR
SETTING BED
TERRAZZO TILE TO TERRAZZO TILE
DOOR AND JAMBDOOR AND JAMBDOOR AND JAMB
LVTLVT
DOOR AND JAMB
LVT TO LVT
FINISH PLAN, FINISH
SCHEDULE, AND GENERAL
NOTES
40 MASSACHUSETTS AVE. NE
WASHINGTON DC 20002
SUITE: 112
2
A2.0
1
A2.0
SP
SP
SP
SP
REFLECTED CEILING PLAN,
LIGHT FIXTURE SCHEDULE,
AND NOTES
40 MASSACHUSETTS AVE. NE
WASHINGTON DC 20002
SUITE: 112
1
A3.0
2
A3.0
SP
SP
SP
SP
MD
CR
DC
CR
MD
DC
CR
POWER AND
COMMUNICATION PLAN
40 MASSACHUSETTS AVE. NE
WASHINGTON DC 20002
SUITE: 112
1
A3.1
2
A3.1
2
A4.0
40 MASSACHUSETTS AVE. NE
WASHINGTON DC 20002
SUITE: 112
2
A4.0
3
A4.0
1
A4.0
4
A4.0
REFERENCE DESK
SALES FLOOR
INTERIOR ELEVATIONS
40 MASSACHUSETTS AVE. NE
WASHINGTON DC 20002
SUITE: 112
1
A4.1
2
A4.1
3
A4.1
4
A4.1
BACK OF HOUSE,
MANAGER'S OFFICE &
EXAM ROOM
INTERIOR ELEVATIONS
40 MASSACHUSETTS AVE. NE
WASHINGTON DC 20002
SUITE: 112
1
A4.2
2
A4.2
3
A4.2
4
A4.2
5
A4.2
6
A4.2
7
A4.2
8
A4.2
9
A4.2
SCALE:A
EZY JAMB DETAIL - EXAM ROOM
N.T.S.
SCALE:C
TYPICAL DOOR HEAD
N.T.S. SCALE:D
TYPICAL DOOR JAMB
N.T.S.
40 MASSACHUSETTS AVE. NE
WASHINGTON DC 20002
SUITE: 112
1
A5.0
SCALE:E
BLIND PIVOT DOOR HEADER
N.T.S.
SCALE:B
EZY JAMB DETAIL - STOCK/ SALES DOOR
N.T.S.
40 MASSACHUSETTS AVE. NE
WASHINGTON DC 20002
SUITE: 112
1
A6.0
2
A6.0
INTERIOR TENANT IMPROVEMENT / FIT-OUT
STORE NO. US (BLUE) 2018
BRANSON LANDING,
BUILDING 1000
SPACE NO. 1003 - 1013
100 BRANSON LANDING BLVD
BRANSON, MO 65616
SITE INFORMATION:
BRANSON LANDING
SPACE NO. 1003-1013
100 BRANSON LANDING BLVD
BRANSON, MO 65616
KEY PLAN (N.T.S.)
THESE PLANS COMPLY WITH THE PROVISION OF TITLE III OF THE "AMERICANS WITH DISABILITIES ACT" (ADA) PUBLIC LAW
101-336, FOR HANDICAPPED ACCESSIBILITY FOR CUSTOMER AND EMPLOYEES.
ALL WORK DONE UNDER THIS CONTRACT SHALL COMPLY WITH THE PROVISIONS OF THE SPECIFICATIONS, DRAWINGS &
CONSTRUCTION CRITERIA OF THE LANDLORD, AND SHALL SATISFY ALL APPLICABLE CODES, ORDINANCES, AND REGULATIONS
OF ALL GOVERNING BODIES INVOLVED. ANY MODIFICATIONS TO THE CONTRACT WORK REQUIRED BY SUCH AUTHORITIES
SHALL BE PERFORMED BY THE GENERAL CONTRACTOR. ALL PERMITS AND LICENSES NECESSARY FOR THE EXECUTION OF THE
WORK SHALL BE SECURED AND PAID FOR BY THE GENERAL CONTRACTOR.
THESE PLANS ARE IN CONFORMANCE WITH THE FOLLOWING CODES:
LOCATION PLAN (N.T.S.)
BUILDING:
PLUMBING:
MECHANICAL:
ELECTRICAL:
ACCESSIBILITY:
FIRE SAFETY CODE:
NORTH
AREA CALCULATIONS
GROSS SQUARE FOOTAGE
SALES AREA:
DISPLAY/POSTER & OPEN WINDOWS:
FITTING ROOMS AREAS:
TOILET ROOMS:
BACK OF HOUSE AREAS:
STOCK ROOM/VISUAL AREA:
TOTAL:
NET SQUARE FOOTAGE
SALES AREA:
DISPLAY/POSTER & OPEN WINDOWS:
FITTING ROOMS AREAS:
TOILET ROOMS:
BACK OF HOUSE AREAS:
STOCK ROOM/VISUAL AREA:
TOTAL:
15,488 SF
1,813 SF
929 SF
161 SF
1,153 SF
1,648 SF
21,192 SF
14,944 SF
1,758 SF
756 SF
145 SF
717 SF
1,475 SF
19, 795 SF
LIST OF DRAWINGSDWG. #
REVISED & ISSUED
ISSUED
E-000
E-210
E-211
E-310
E-410
E-411
E-412
E-501
E-502
E-601
E-602
E-701
E-702
E-703
E-704
E-705
E-706
E-800
E-901
M-000
M-210
M-500
M-700
M-800
M-901
M-902
P-500
P-900
ELECTRICAL LEGENDS, NOTES AND DETAILS
GENERAL LIGHTING PLAN
TRACK LIGHTING PLAN
POWER PLAN
AUDIO PLAN
SECURITY PLAN
FIRE ALARM PLAN
ENLARGED BOH POWER PLANS
ENLARGED POWER PLANS
POWER RISER DIAGRAM
PANEL SCHEDULES
EMS DETAILS
POWERLINK CONTROLS
ELECTRICAL DETAILS
FIRE ALARM RISER NOTES AND DETAILS
SECURITY DETAILS
BACK OF HOUSE ELEVATIONS
LIGHTING FIXTURE SCHEDULE
ELECTRICAL SPECIFICATIONS
MECHANICAL TITLE SHEET
HVAC PLAN
ENLARGED BOH HVAC PLAN
HVAC DETAILS
HVAC SCHEDULES
MECHANICAL SPECIFICATIONS
MECHANICAL COMMISSIONING SPECIFICATIONS/FORMS
ENLARGED PLUMBING PLAN AND DETAILS
PLUMBING SPECIFICATIONS
FIRE PROTECTION PLAN
FIRE PROTECTION SPECIFICATIONS
FP-210
FP-900
LANDLORD'S REPRESENTATIVE
HCW
153 SOUTH PAYNE STEWART DRIVE
BRANSON, MO 65616
TEL: 417-332-3438
CONTACT: BARRY SCHWARTZ
TITLE: EXECUTIVE VICE PRESIDENT/CFO
E-MAIL: BSCHWARTZ@HCW.US
TITLE SHEET
GENERAL NOTES AND RESPONSIBILITY SCHEDULE
EGRESS PLANS
CONSTRUCTION PLANS
DIMENSION PLANS
CONSTRUCTION PLAN GENERAL AND KEY NOTES
REFLECTED CEILING PLANS
CEILING COORDINATION PLANS
FIXTURE PLANS
FIXTURE SCHEDULE
FINISH PLANS
FINISH PLAN LEGENDS AND NOTES
GRAPHIC DETAILS
NAVIGATION SIGN DETAILS
ENLARGED STOREFRONT PLANS AND ELEVATIONS
ENLARGED STOREFRONT PLANS, ELEVATIONS AND DETAILS
STOREFRONT SECTIONS
STOREFRONT SECTIONS
STOREFRONT SECTIONS
STOREFRONT DETAILS
SIGNAGE DETAILS
INTERIOR ELEVATIONS
INTERIOR ELEVATIONS
INTERIOR ELEVATIONS
INTERIOR ELEVATIONS
PARTITION TYPES
PARTITION TYPES AND BOX BEAM DETAILS
FIXTURE, CASHWRAP AND MISC. DETAILS
FLOORING AND BASE DETAILS
COLUMN ENCLOSURE DETAILS AND ELEVATIONS
COLUMN AND PORTAL DETAILS
CEILING DETAILS
FITTING ROOM AREA #1 & #2 ENLARGED PLANS AND ELEVATIONS
FITTING ROOM DETAILS
ENLARGED BOH PLAN, NOTES AND SCHEDULES
BOH MILLWORK DETAILS AND ELEVATIONS
BOH MILLWORK DETAILS AND ELEVATIONS
TOILET ROOM AND JANITOR'S CLOSET PLAN AND ELEVATIONS
DOOR SCHEDULE
DOOR DETAILS
SPECIFICATIONS
SPECIFICATIONS
SPECIFICATIONS
A-000
A-010
A-110
A-210
A-211
A-212
A-310
A-311
A-410
A-421
A-510
A-511
A-550
A-551
A-600
A-601
A-602
A-603
A-604
A-608
A-609
A-610
A-611
A-612
A-613
A-700
A-701
A-702
A-710
A-711
A-712
A-720
A-730
A-731
A-740
A-741
A-742
A-743
A-800
A-801
A-930
A-931
A-932
H&M
STORE NO. US667
BRANSON LANDING
SPACE NO. 1003-1013
100 BRANSON LANDING BLVD
BRANSON, MO 65616
12.18.17CLIENT/LANDLORDREVIEW
CODE ANALYSISPROJECT DIRECTORY LIST OF DRAWINGS
BUILDING DEPARTMENT
CITY OF BRANSON
110 WEST MADDUX
BRANSON, MO 65616
TEL: (417)-334-3345
EXISTING TENANT'S TO BE RE-DEMISED (BY H&M)
SPACE # 1003 - CHICO'S
SPACE # 1005 - VACANT
SPACE # 1007-1013 - VACANT
*REFER TO LANDLORD'S DRAWINGS FOR SCOPE OF WORK PERTAINING TO SHELL BLDG. / RE-DEMISE OF
EXISTING SPACES
NORTH
2015 INTERNATIONAL BUILDING CODE (WITH LOCAL AMENDMENTS)
2015 INTERNATIONAL PLUMBING CODE (WITH LOCAL AMENDMENTS)
2015 INTERNATIONAL MECHANICAL CODE (WITH LOCAL AMENDMENTS)
2014 NATIONAL ELECTRICAL CODE (WITH LOCAL AMENDMENTS)
ICC/ANSI A117.1-2009 EDITION
2015 INTERNATIONAL FIRE CODE
USE GROUP: M - MERCANTILE (309.1)
S-1 - STORAGE (311.2)
SEPARATED OCCUPANCIES (508.4/508.4)
CONSTRUCTION TYPE: II A PROTECTED
NON-COMBUSTIBLE
(SECTION 601, TABLE 601)
OCCUPANT LOAD (APPLICABLE TABLE):
SALES AREA (GRADE FLOOR) + DISPLAY/POSTER & OPEN WINDOWS +
FITTING ROOMS + TOILET ROOMS:
STOCK ROOM + VISUAL AREA + NIGHTBOX + REMOTE NIGHTBOX:
TOTAL OCCUPANT LOAD:
18,391 / 60 SF PER PERSON = 306 PEOPLE
2,801 / 300 SF PER PERSON = 9 PEOPLE
= 315 PEOPLE
NUMBER OF EXITS PROPOSED:
(2) EXITS
PROVIDED:
204" (17'-0"), 44" WIDE MIN. PATH
30" MIN. (SECTION 1018.4)
PROPOSED:
1 MALE, 1 FEMALE (FOR EMPLOYEE USE)
1 MALE, 1 FEMALE (FOR EMPLOYEE USE)
1 HI-LO TYPE
1
REQUIRED:
1 MALE, 1 FEMALE
1 MALE, 1 FEMALE
1
1
EXIT REQUIREMENTS: (SECTION 1022.1):
NUMBER OF EXITS REQUIRED:
(2) EXITS FOR OCCUPANT LOAD OF 1 - 500
EXIT WIDTH REQ'D. (SECTION 1005.3.2):
0.2" PER OCCUPANT x 315 OCCUPANTS = 63"
MIN. AISLE WIDTH REQ'D.:
MIN. PLUMBING FIXTURE REQUIREMENTS: (IPC, TABLE 403.1)
DISTANCE TO PUBLIC FACILITIES (SECTION 403.3.4): > 300'
PLUMBING FACILITIES WITHIN TENANT SPACE ARE EMPLOYEE FACILITIES ONLY (SECTION 403.3.4)
MAX. NUMBER OF EMPLOYEES AT A TIME; 18 PEOPLE
FIXTURE:
WATER CLOSET
LAVATORY
DRINKING FOUNTAIN
SERVICE SINK
REVISED & ISSUED
ISSUED
LIST OF DRAWINGS
H&M
STORE NO. US667
BRANSON LANDING
SPACE NO. 1003-1013
100 BRANSON LANDING BLVD
BRANSON, MO 65616
LIST OF DRAWINGSDWG. #
VENDOR LIST
12.18.17CLIENT/LANDLORDREVIEW
TENANT
H&M HENNES & MAURITZ
110 FIFTH AVENUE, 11TH FLOOR
NEW YORK, NY 10011
TEL: 347-835-7856
CONTACT: KATIE HWANG
TITLE: PROJECT MANAGER
EMAIL: KATIE.HWANG@HM.COM
ARCHITECT
SARGENTI ARCHITECTS
ROBERT SARGENTI, PRINCIPAL ARCHITECT
461 FROM ROAD, 2ND FLOOR
PARAMUS, NJ 07652
TEL: 973-253-9393
CONTACT: ALICE PINTO
TITLE: SENIOR PROJECT MANAGER
E-MAIL: APINTO@SARGARCH.COM
*
EAS
CONTROLTEK
95 DERMODY STREET
CRANFORD, NJ 07016
TEL: 888-808-6970
CONTACT: STEVE SELL
E: STEVE.SELL@CONTROLTEKUSA.COM
CONTACT: STEFANIE HOOVER
E. STEFANIE.HOOVER@CONTROLTEKUSA.COM
BURGLAR ALARM
FE MORAN
201 W. UNIVERSITY AVE.
CHAMPAIGN, IL, 61821
TEL: 217-403-6444
CONTACT: JANNA CAPUTO HILL
TITLE: PROJECT MANAGER
E: JSTEFFAN@FEMORANSECURTIY.COM
CCTV
S-TRON
1227 WALT WHITMAN RD
MELVILLE, NY, 11747
TEL: 860-668-7777
CONTACT: BOB KASPERSKI
TITLE: PROJECT MANAGER
E-MAIL: BKASPERSKI@S-TRON.COM
BMS SYSTEM
T-WAVE
1012 CENTRAL AVE S.
KENT, WA 98032
253-867-2333
CONTACT: JERRY SCOTT
E: JERRY.S@TWAVETECH.COM
AUDIO/SPEAKERS
(RECOMMENDED VENDOR)
ECI
3100 NW BOCA RATON BLVD.
SUITE 106
BOCA RATON, FL 33431
TEL: 561-416-5880
CONTACT: BART RENO
E: RENO0369@YAHOO.COM
IT SYSTEM
H&M
3000 LIGHTNING WAY - 1ST FLR
SECAUCUS, NJ 07094
TEL: 646-321-2897
CONTACT: MARC DAVIS
TITLE: IT-PROJECT MANAGEMENT
E-MAIL: MARC.DAVIS@HM.COM
CONTACT: KAMRAN JAVED
SAFE
WIILSON SAFE
3031 ISLAND AVENUE
PHILADELPHIA, PA 19153
TEL: 800-345-8053
CONTACT: BOB KASSOFF
TITLE: SALES
E-MAIL: RKASSOFF@WILSONSAFE.COM
AUDIO/SPEAKERS
(RECOMMENDED VENDOR)
DIGITRON
CONTACT: JIM ANKER
E: JIM@DIGITRON.NET
AUDIO/SPEAKERS
(RECOMMENDED VENDOR)
MOOD MEDIA
CONTACT: CRAIG BREIGLE
E: CRAIG.BREIGLE@MOODMEDIA.COM
SIGNAGE
JONES SIGN
400 MACK DRIVE
CROYDON, PA 19021
TEL: 609-458-6807
CONTACT: NELLIE MCDERMOTT
TITLE: REGIONAL VP NATIONAL SALES
E: NMCDERMOTT@JONESSIGN.COM
CUBE
S-TRON
1227 WALT WHITMAN RD
MELVILLE, NY, 11747
TEL: 860-668-7777
CONTACT: BOB KASPERSKI
TITLE: PROJECT MANAGER
E-MAIL: BKASPERSKI@S-TRON.COM
REMOTE NIGHT BOX
REVISION:
SHEET TITLE:
SPACE NO.:
ARCH PROJECT NO.:
SCALE:
DRAWN BY:
REV. NO:
SHEET NO:
PRODUCT SEASON:
2018
US667-BLUE
BRANSONLANDING
BUILDING1000
SPACENOS.1003-1013
100BRANSONLANDINGBLVD
BRANSON,MOZIP65616
AS NOTED
2018
2187-17
ISSUE DATE:
1003-1013
D.O.B. NO:
12.18.17 CLIENT/LANDLORD REVIEW
4 6 1 F R O M R O A D
PARAMUS, NJ 07652
973.253.9393 TEL
973.253.9390 FAX
WWW.SARGARCH.COM
VP
A-000
TITLE SHEET
GENERAL CONDITIONS
SECTIONELEVATION SECTION DETAIL PLAN DETAIL
X
PARTITION TYPE
COLUMN TAG
FINISH TAG
X
REVISION CLOUD
ALL WORK IS TO CONFORM TO ALL APPLICABLE CODES AND REGULATIONS.
THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL REQUIRED PERMITS AND APPROVALS PRIOR TO COMMENCEMENT OF WORK.
THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL REQUIRED INSPECTIONS AND CERTIFICATES.
THE CONTRACTOR WILL BECOME FAMILIAR WITH EXISTING CONDITIONS AND SHALL VERIFY EXISTING FIELD CONDITIONS IN THE FIELD PRIOR TO
COMMENCEMENT OF THE WORK, AND SHALL REPORT ANY DISCREPANCIES BETWEEN THE DRAWINGS AND FIELD CONDITIONS TO THE ARCHITECT.
FOR GENERAL CONDITIONS REFER TO AIA DOCUMENT A107 2007.
ALL WORK TO BE WARRANTED FOR A PERIOD NO LESS THAN ONE YEAR.
THE CONTRACTOR SHALL COORDINATE ALL WORK PROCEDURES WITH REQUIREMENTS OF LOCAL AUTHORITIES AND BUILDING MANAGEMENT.
ALL ELECTRICIANS AND PLUMBERS INVOLVED IN THE WORK ARE TO BE LICENSED AND BONDED.
ELECTRICAL WORK SHALL BE FILED SEPARATELY BY THE ELECTRICAL SUBCONTRACTOR.
DEMOLITION IS TO BE PERFORMED IN AN ORDERLY MANNER, PER THE RESTRICTIONS, REGULATIONS, AND HOURS SET BY THE BUILDING
MANAGEMENT. DEBRIS IS TO BE DISCARDED OFF SITE IN A PROPER MANNER AND NOT BE ALLOWED TO ACCUMULATE IN THE WORK AREA.
DIMENSIONS GIVEN ARE TO FINISH SURFACES UNLESS NOTED OTHERWISE.
THE CONTRACTOR SHALL LAY OUT HIS OR HER OWN WORK, AND SHALL PROVIDE ALL DIMENSIONS REQUIRED FOR OTHER TRADES (PLUMBING,
ELECTRICAL, ETC...)
G.C. TO CHECK WITH LANDLORD FOR TYPE OF CONNECTIONS & POINT ATTACHMENT TO EXISTING STRUCTURE AND SLAB PRIOR TO PERFORM
WORK.
G.C. TO COORDINATE WITH ALL H & M VENDORS AND SUPERVISORS AT JOB SITE.
G.C. AND HIS FLOOR CONTRACTORS TO INSPECT FLOOR AT TIME OF H & M POSSESSION OF SPACE FROM LANDLORD & ADVISE H & M OF ANY
PROBLEMS OR DEFICIENCIES.
G.C. TO SCHEDULE H&M VENDOR DELIVERIES WITH H&M PROJECT MANAGER.
PROPOSED WORK TO COMPLY WITH APPLICABLE REQUIREMENTS OF LOCAL LAWS FOR HANDICAPPED ACCESS.
TOILET ROOMS TO COMPLY WITH THE APPLICABLE REQUIREMENTS OF LOCAL LAWS FOR HANDICAPPED ACCESSIBILITY.
ACCESSIBLE ROUTES TO BE PROVIDED, PROVIDING A MINIMUM OF 32 INCHES OF WIDTH AT DOORWAYS.
EMERGENCY WARNING SYSTEMS SHALL INCLUDE BOTH AUDIBLE AND VISUAL ALARMS AS PER CODE REQUIREMENTS.
PROPOSED STORAGE FACILITIES SUCH AS CABINETS, SHELVES, CLOSETS, AND DRAWERS SHALL COMPLY WITH APPLICABLE REQUIREMENTS OF H.C.
ACCESSIBILITY OF LOCAL LAWS :
A. CLEAR FLOOR SPACE OF A MINIMUM OF 30 INCHES BY 48 INCHES SHALL BE PROVIDED FOR APPROACH TO ALL STORAGE FACILITIES.
B. STORAGE SPACES SHALL COMPLY WITH AT LEAST ONE OF THE REACH RANGES SPECIFIED IN H.C. APPLICABLE ACCESSIBILITY CODES. CLOTHES
RODS SHALL
BE A MAXIMUM OF 54 INCHES OFF THE FLOOR.
C. HARDWARE FOR STORAGE FACILITIES SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR
TWISTING OF THE WRIST.
GENERAL
ALL WORK TO BE DONE IN ACCORDANCE WITH THE LOCAL BUILDING CODE, AND REGULATIONS OF ALL OTHER AGENCIES HAVING JURISDICTION.
STRUCTURAL
A. CONTRACTOR TO PROVIDE ADEQUATE TEMPORARY BRACING AND SHORING WHEREVER ANY STRUCTURAL WORK IS INVOLVED.
B. ALL DEMOLITION OPERATION, REPAIR OPERATIONS, AND ALTERATION OPERATIONS TO BE DONE IN ACCORDANCE WITH (APPLICABLE BUILDING
CODE)
MEANS OF EGRESS
ALL EXISTING MEANS OF EGRESS FOR TENANTS OF THE BUILDING TO BE MAINTAINED CLEAR AND FREE OF ALL OBSTRUCTIONS, SUCH AS BUILDING
MATERIALS, TOOLS, ETC.
FIRE SAFETY
A. ALL BUILDING MATERIALS STORED AT CONSTRUCTION AREA, AND/ OR GENERAL CONTRACTOR.
B. ALL MATERIALS TO BE STORED IN AN ORDERLY FASHION.
C. ALL FLAMMABLE MATERIALS TO BE KEPT AWAY FROM HEAT.
D. ALL FLAMMABLE MATERIALS TO BE USED AND STORED IN AN ADEQUATELY VENTILATED SPACE.
E. ALL ELECTRICAL POWER TO BE SHUT-OFF WHERE THERE ARE EXPOSED CONDUITS.
F. ALL ELECTRICAL POWER IN THE CONSTRUCTION AREA TO BE SHUT OFF AFTER WORKING HOURS.
G. CONTRACTOR, AT ALL TIMES, TO MAKE SURE THERE ARE NO LEAKS OF NATURAL GAS IN BUILDING, OR ANY FLAMMABLE GAS USED IN
CONSTRUCTION.
DUST CONTROL
A. DEBRIS, DIRT, AND DUST TO BE KEPT TO A MINIMUM, AND BE CONFINED TO THE IMMEDIATE CONSTRUCTION AREA.
B. CONTRACTOR TO ISOLATE CONSTRUCTION AREA FROM OCCUPIED BUILDING AREAS BY MEANS OF TEMPORARY PARTITIONS OR HEAVY WEIGHT
DROP CLOTHES.
C. DEBRIS, DIRT, AND DUST TO BE CLEANED UP AND CLEARED FROM BUILDING PERIODICALLY TO AVOID ANY EXCESSIVE ACCUMULATION.
NOISE AFTER HOURS
A. CONSTRUCTION OPERATIONS WILL BE CONFINED TO NORMAL WORKING HOURS: 8 A.M. TO 5 P.M., MONDAYS THROUGH FRIDAYS, EXCEPT
LEGAL HOLIDAYS.
B. CONTRACTOR TO OBTAIN PERMITS AND THE WRITTEN CONSENT OF ALL PARTIES AFFECTED BY HIS WORKING DURING OTHER THAN REGULAR
HOURS. COORDINATE WITH MALL MANAGEMENT/LANDLORD'S REPRESENTATIVE.
X
X
X REVISION TAG
X KEYNOTE TAG
ROOM NAME
RM #
AFF
FINISH
CEILING TAG
ELEVATION TAG
ROOM TAG
A. FIELD CONDITIONS
CONTRACTOR SHALL VERIFY ALL CONDITIONS AS WELL AS ALL DIMENSIONS AND CONDITIONS INDICATED IN THE
DRAWINGS, PRIOR TO ACTUAL CONSTRUCTION. ANY VARIATION FROM CONDITIONS INDICATED IN THE DRAWINGS
SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND OWNERS REPRESENTATIVE PRIOR TO COMMENCING
WORK.
B. COORDINATION OF WORK
THE CHARACTER AND SCOPE OF THE WORK ARE ILLUSTRATED BY THE WORKING DRAWINGS. CONTRACTOR SHALL
CAREFULLY EXAMINE ALL THE DRAWINGS AND BE RESPONSIBLE FOR THE PROPER INSTALLATION OF HIS WORK AND
PROPER CONSIDERATION FOR THE WORK OF OTHERS AND EXISTING BUILDING CONSTRUCTION. DO NOT PLACE
DUCTS, PIPING, CONDUIT OR ANY OBSTRUCTION SO AS TO IMPAIR REQUIRED CEILING HEIGHTS AND CLEARANCE FOR
LIGHTING FIXTURES, ETC. CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF EXISTING ADJACENT
TENANT(S) AND BUILDING FACILITIES. CONTRACTOR TO COORDINATE WITH LANDLORD AND OBTAIN AND FOLLOW
BUILDING RULES AND REGULATIONS FOR CONSTRUCTION.
C. BUILDING CODES AND REGULATIONS
ALL WORK SHALL CONFORM TO ALL CODES AND REGULATIONS. CONTRACTOR SHALL FILE, PAY FOR, AND OBTAIN ALL
REQUIRED PERMITS TO PERFORM THE WORK. CONTRACTOR SHALL OBTAIN ALL REQUIRED APPROVALS FROM
GOVERNMENTAL AGENCIES INVOLVED PRIOR TO FINAL PAYMENT. APPROVALS TO OCCUPY THE SPACE BY LOCAL
BUILDING OFFICIALS SHALL BE OBTAINED.
D. INSURANCE
1. CONTRACTOR SHALL SECURE, PAY FOR, AND MAINTAIN DURING CONSTRUCTION FIXTURING WORK WITHIN
LEASED PREMISES, ALL OF THE INSURANCE POLICIES REQUIRED AND IN THE AMOUNTS AS SET FORTH HEREIN.
CONTRACTOR SHALL NOT COMMENCE ANY WORK UNTIL ALL REQUIRED INSURANCE HAS BEEN OBTAINED AND
CERTIFICATES OF SUCH INSURANCE HAVE BEEN DELIVERED TO THE LANDLORD AND TENANT. LANDLORD AND H &
M, HENNES & MAURITZ, LP, 110 5TH AVENUE, NEW YORK, NY 10011 MUST BE NAMED AS "ADDITIONAL INSURED".
THIS WORDING NEEDS TO BE INCLUDED: THE FOLLOWING PARTIES AS ADDITIONAL INSURED: ALL PARTIES
INCLUDING H & M, HENNES & MAURITZ, LP, 110 5TH AVENUE, NEW YORK, NY 10011 RESPECTED OFFICERS,
AGENTS, EMPLOYEES AND AFFILIATES OF ALL OF THE AFOREMENTIONED PARTIES. AN AFFILIATE SHALL BE DEFINED
AS ANY CORPORATE ENTITY WHICH IS A PARENT OR SUBSIDIARY OF ANY OF THE AFOREMENTIONED PARTIES, OR
WHICH HAS THE SAME PARENT CORPORATION AS ANY OF THE AFOREMENTIONED PARTIES. CERTIFICATES OF
INSURANCE SHALL COVER ALL WORK PERFORMED BY G.C. AND EACH OF HIS SUBCONTRACTORS AND ALL MAJOR
SUPPLIERS.
2. GENERAL CONTRACTOR'S AND SUBCONTRACTORS' REQUIRED MINIMUM COVERAGE AND LIMITS OF LIABILITY:
A. WORKMEN'S COMPENSATION INSURANCE - IN ACCORDANCE WITH THE GOVERNING LAWS WITH A LIMIT OF NOT
LESS THAN $1,000,000. AND ANY INSURANCE REQUIRED BY ANY EMPLOYEE BENEFITS ACTS, ETC. AS WILL PROTECT THE
CONTRACTOR AND SUBCONTRACTORS FROM ANY AND ALL LIABILITY.
B. CONTRACTOR SHALL PAY FOR AND FURNISH TO TENANT AND LANDLORD, CERTIFICATES OF INSURANCE WHICH WILL
PROTECT SAID CONTRACTOR FROM CLAIMS (i) UNDER WORKMAN'S COMPENSATION ACTS AND OTHER EMPLOYEE
BENEFIT ACTS, WITH LIMITS OF NOT LESS THAN $5,000,000.; (ii) FOR DAMAGES BECAUSE OF BODILY INJURY,
(INCLUDING DEATH) TO HIS EMPLOYEES AND ALL OTHERS, WITH THE LIMITS OF $5,000,000 PER PERSON AND
$5,000,000. PER OCCURRENCE; AND (iii) FOR DAMAGES TO PROPERTY WITH LIMITS OF $5,000,000. WHICH ARISE OUT
OF OR RESULT FROM THE CONTRACTOR'S WORK UNDER THIS CONTRACT WHETHER SUCH WORK (INCLUDING
OPERATION OF MOTOR VEHICLES) BE BY HIMSELF OR OTHERS DIRECTLY OR INDIRECTLY EMPLOYED BY EITHER; AND
BUILDERS RISK INSURANCE IN THE FULL AMOUNT OF THE CONTRACT SUM. EXCESS / UMBRELLA LIABILITY $10,000,000
EACH OCCURRENCE AND $10,000,000 AGGREGATE.
C. CONTRACTOR SHALL ALSO PROVIDE GENERAL LIABILITY INSURANCE AS FOLLOWS - $1,000,000 EACH OCCURRENCE
AND $2,000,000 GENERAL AGGREGATE.
3. INDEMNIFICATION - TO THE FULLEST EXTENT PERMITTED BY LAW, THE CONTRACTOR SHALL INDEMNIFY AND HOLD
HARMLESS THE LANDLORD, TENANT, AND THE ARCHITECT AND THEIR AGENTS AND EMPLOYEES FROM AND
AGAINST ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES, INCLUDING BUT NOT LIMITED TO ATTORNEY'S FEES
ARISING OUT OF OR RESULTING FROM THE PERFORMANCE OF THE WORK, PROVIDED THAT ANY SUCH CLAIM,
DAMAGE, LOSS, OR EXPENSE (1) IS ATTRIBUTABLE TO BODILY INJURY, SICKNESS, DISEASE, OR DEATH, OR TO INJURY
OR TO DESTRUCTION OF TANGIBLE PROPERTY (OTHER THAN THE WORK ITSELF) INCLUDING THE LOSS OF USE
RESULTING THEREFROM, AND (2) IS CAUSED IN WHOLE OR IN PART BY A NEGLIGENT ACT OR OMISSION OF THE
CONTRACTOR, ANY SUBCONTRACTORS, ANYONE DIRECTLY OR INDIRECTLY EMPLOYED BY ANY OF THEM MAY BE
LIABLE, REGARDLESS OF WHETHER OR NOT IT IS CAUSED IN PART BY A PARTY INDEMNIFIED HEREUNDER.
E. LIEN WAIVERS AND SWORN AFFIDAVITS
CONTRACTOR SHALL FURNISH WITHIN 30 DAYS AFTER COMPLETION, FINAL WAIVERS OF LIEN FOR ALL WORK
PERFORMED AS WELL AS ALL SUBCONTRACTORS AND MAJOR SUPPLIERS
F. CERTIFICATE OF OCCUPANCY
CONTRACTOR WILL PROVIDE TENANT AND LANDLORD WITH A COPY OF THE CERTIFICATE OF OCCUPANCY.
G. QUALITY STANDARDS
ALL SUCH WORK SHALL BE PERFORMED IN A FIRST CLASS WORKMANLIKE MANNER AND SHALL BE IN GOOD AND
USEABLE CONDITION AT THE DATE OF COMPLETION THEREOF. CONTRACTOR SHALL GUARANTEE ALL WORK
PERFORMED TO BE FREE FROM ANY AND ALL DEFECTS IN WORKMANSHIP AND MATERIALS FOR ONE (1) YEAR FROM THE
DATE ALL CONSTRUCTION PUNCH LIST ITEMS HAVE BEEN COMPLETED AND ACCEPTANCE HAS BEEN CONFIRMED IN
WRITING BY THE TENANT REPRESENTATIVE. CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPLACEMENT OR REPAIR
WITHOUT ANY ADDITIONAL CHARGE FOR ANY AND ALL WORK DONE OR FURNISHED WHICH SHALL BECOME
DEFECTIVE WITHIN THIS ONE (1) YEAR PERIOD. THE CORRECTION OF SUCH WORK SHALL INCLUDE, WITHOUT
ADDITIONAL CHARGE, ALL EXPENSES AND DAMAGES IN CONNECTION WITH SUCH REMOVAL, REPLACEMENT, OR REPAIR
OF ANY PART OF THE WORK WHICH MAY BE DAMAGED OR DISTURBED THEREBY. ALL WARRANTIES OR GUARANTEES
AS TO MATERIALS OR WORKMANSHIP ON OR WITH RESPECT TO TENANT'S WORK SHALL BE CONTAINED IN THE
CONTRACT OR SUBCONTRACT WHICH SHALL BE SO WRITTEN THAT SUCH GUARANTEES OR WARRANTEES SHALL INSURE
TO THE BENEFIT OF BOTH LANDLORD AND TENANT, AS THEIR RESPECTIVE INTEREST APPEAR AND CAN BE DIRECTLY
ENFORCED BY EITHER.
H. RUBBER WHEEL CARTS
CONTRACTOR'S CARTS, EQUIPMENT BOXES, ETC., MUST BE EQUIPPED WITH RUBBER WHEELS.
J. FIRE EXTINGUISHERS
EXISTING LOCATIONS TO BE MAINTAINED, IF IT ACCOMMODATES NEW LAYOUT WHERE APPLICABLE. CONTRACTOR TO
VERIFY REQUIRED NUMBER AND LOCATION OF ANY ADDITIONAL EXTINGUISHERS REQUIRED BY FIRE DEPARTMENT AND
FURNISH AND INSTALL SAME. INSTALL AFTER FIXTURING.
K. RESPONSIBILITY FOR MATERIALS ON SITE
CONTRACTOR SHALL BE RESPONSIBLE FOR ALL MATERIALS SHIPPED TO THE JOB SITE INCLUDING MATERIALS FURNISHED
BY OTHERS. COST OF ALL MISSING MATERIALS WILL BE DEDUCTED FROM THE CONTRACT PRICE AND FINAL PAYMENT.
CONTRACTOR TO CHECK ALL INVOICES AT TIME SHIPMENT IS RECEIVED AND NOTIFY TENANT REPRESENTATIVE OF ANY
DISCREPANCIES, DAMAGED OR MISSING ITEMS WITHIN 48 HOURS OF DELIVERY.
L. RUBBISH REMOVAL
CONTRACTOR SHALL BE RESPONSIBLE FOR DAILY REMOVAL FROM THE PROJECT, ALL TRASH, RUBBISH AND SURPLUS
MATERIALS RESULTING FROM CONSTRUCTION, FIXTURING AND MERCHANDISING OF THE DEMISED PREMISES.
COORDINATE REMOVAL OF DEBRIS WITH SHOPPING CENTER MGMT.
GENERAL NOTES
CONSTRUCTION
LEASE LINE
FIRE RATED OR RETARDANT
DESIGN CONTROL LINE
CERAMIC TILE
MATERIAL
GYPSUM WALLBOARD
FINISH OR FINISHED
EACH
CONTRACTOR
CEILING
CEILING HEIGHT
BACK OF HOUSE
L.L.
MATL.
GYP. BD.
F.R.
FIN.
=
=
=
=
=
CONTR.
C.T.
D.C.L.
EA.
CONST.
C.H.
B.O.H.
CLG.
=
=
=
=
=
=
=
FIBERGLASS REINFORCED PANELSFRP =
HOLLOW METALHM =
GENERAL CONTRACTORG.C. =
=
BOTTOM OFB.O. =
EXISTING(E)/EXIST./EX'G. =
AUTHORITY HAVING JURISDICTIONAHJ =
ACOUSTICAL CEILING TILEACT =
FIRE RETARDANT TREATEDFRT =
CENTER LINEC =L
EQUIPMENTEQUIP. =
HOURHR. =
MAXIMUMMAX. =
COLUMNCOL. =
ALUMINUMAL OR ALUM. =
MIN. MINIMUM=
LOCAL LAWS (HANDICAPPED ACCESS)
TENANT'S SAFETY PLAN
ABBREVIATIONS AND DEFINITIONS
SYMBOLS
DOOR TAG
DETAIL
NUMBER
AREA
DETAILED
SHEET
LOCATOR
ACCESSIBILITY CLEARANCES
NOTE: * = 48 IN (1220
MM) MINIMUM IF DOOR
HAS BOTH A CLOSER.
NOTE: * = 48 IN (1220 MM)
MINIMUM IF DOOR HAS
BOTH A LATCH AND
CLOSER.
42"MIN
1065mm
54" MIN
1370 mm
NOTE: * = 54 IN (1370 MM)
MINIMUM IF DOOR HAS CLOSER.
48"MIN
1220mm
PUSH SIDE
24" MIN
610 mm
42"MIN
1065mm
PUSH SIDE
PULL SIDE
NOTE: X = 36 IN (915 MM) MINIMUM IF Y = 60 IN (1525 MM);
X = 42 IN (1065 MM) MINIMUM IF Y = 54 IN (1370 MM).
PUSH SIDE
Y
X
PULL SIDE
PULL SIDE
ANSI FIG.404.2.4.1
MANEUVERING CLEARANCE AT SWINGING DOORS
(A) FRONT APPROACH, PULL SIDE (B) FRONT APPROACH, PUSH SIDE (C) HINGE APPROACH, PULL SIDE
(D) HINGE APPROACH, PUSH SIDE (E) LATCH APPROACH, PULL SIDE (F) LATCH APPROACH, PUSH SIDE
12 IN (305 MM) MIN
WHERE LATCH + CLOSER
ARE PROVIDED
LOUNGE SINK
30" MIN
760
815710
28"32"36"
915
(A) BEFORE REMOVAL OF CABINETS AND BASE (B) CABINETS AND BASE REMOVED AND HEIGHT
ALTERNATIVES
22" MIN
560
12 IN (305 MM) MIN
WHERE LATCH + CLOSER
ARE PROVIDED
60"MIN
1525mm
18" MIN
445 mm
48"MIN
1220mm
24" MIN
610 mm
TEMPORARY UTILITIES
PRE-CONSTRUCTION
ARCHITECTURAL
MECHANICAL
ELECTRICAL
PLUMBING
FIRE PROTECTION
POST CONSTRUCTION
NOTE 1 ELECTRICAL SERVICE AND CONNECTIONS BY GENERAL CONTRACTOR
NOTE 4 SEE DWGS. FOR ADDT'L. REQ'TS. FOR EX'G. DEMISING PARTITIONS TO BE COMPLETED BY GC. GC TO V.I.F. BEFORE BID
NOTE 2 GENERAL CONTRACTOR TO PURCHASE SCHEDULED FIXTURES FROM TENANTS VENDOR
NOTE 3 SEE ACCESSORY SCHEDULE ON DRAWINGS
NOTE 6 INCLUDING MODIFICATION OF ANY EXISTING HEAD LOCATIONS
NOTE 5 INSTALLATION TO INCLUDE, UNLOADING, UNPACKING, ASSEMBLY AS REQ'D. AND PLACEMENT AS DIRECTED BY TENANT
CLARIFICATION/ REMARKS
TENANT
TEN.VENDOR
TENANTG.C.
TENANT
LANDLORD
SEE DWGS. FOR NOTES
SEE NOTE 5
SEE NOTE 5
SEE NOTE 7
REFER TO RCP SHEETS FOR MORE INFO.
SEE NOTES 1 & 5, CONDUIT & PULL STRING BY G.C., AS
NOTED IN ELECTRICAL SHTS.
REFER TO ELEC. SHTS. FOR MORE INFO.
SEE NOTE 5
SEE NOTE 5
SEE NOTE 5 & HARDWARE SCHEDULE
SEE NOTE 5, G.C. TO PROVIDE BLK'G.
NOTE 7 INCLUDING BUT NOT LIMITED TO POS DATA, AND COMMUNICATIONS
SAW CUTTING, CORING, CHANNELING OF EXISTING CONCRETE
DEMOLITION WORK IN LEASED AREA
CONCRETE FLOOR SLAB
PREPARATION OF FLOOR SLAB FOR NEW FINISHES (INCL. LEVELING & PATCHING AS REQ'D.)
CONTROL AND EXPANSION JOINTS IN CEILING, WALLS AND FLOORS
RATED DEMISING PARTITION GYPSUM BOARD
RATED DEMISING PARTITION STUDS
PARTITIONS WITHIN LEASED SPACE
METAL STRAPPING, BLOCKING AND LEDGERS
ACOUSTIC AND THERMAL INSULATION
WALL FINISHES INCLUDING BUT NOT LIMITED TO PAINT
RECESSED AND WALL MOUNTED STANDARDS, PANELS AND ASSOCIATED INSTALLATION COMPONENTS
BACK OF HOUSE MILLWORK AND ASSOCIATED SHOP DRAWINGS
BACK OF HOUSE COLORED CORNER GUARDS & WALL PROTECTION (FRP)
SALES AREA / FITTING ROOM AREA(S) ALUMINUM WALL BASE
BACK OF HOUSE VINYL WALL BASE
HOLLOW METAL DOORS, FRAMES, AND DOOR HARDWARE
FITTING ROOM DOORS, FRAMES, CURTAINS, CURTAIN RODS, AND HARDWARE
FITTING ROOM COMPARTMENT ACCESSORIES
ACOUSTIC TILE CEILING SYSTEM
GYP BOARD CEILINGS, GYP BOARD SOFFITS, AND SUPPORT FRAMING & ACCESS DOORS/PANELS
MIRRORS - SALES FLOOR AS INDICATED
MIRRORS FITTING ROOM COMPARTMENTS AS INDICATED & SPECIAL MIRRORS
CASHWRAP AND FREE STANDING FLOOR FIXTURES
COUNTERS, CABINETS, SHELVING AND MISC. CASEWORK AT BACK OF HOUSE
FLOOR SAFE AT OFFICE
FLOOR, ROOF PENETRATIONS AND PATCHING
HVAC DUCTWORK AND SUPPORTING FRAMING
HVAC DIFFUSERS AND GRILLES
SMOKE DETECTORS
DAMPERS
EXHAUST FANS
CONTROLS AND CONNECTIONS
OUTSIDE AIR INTAKE
TESTING AND BALANCING
ALL EQUIPMENT ON TENANT RISER DIAGRAM
DATA AND COMMUNICATIONS WIRING
LIGHT FIXTURES -SALES AND DISPLAY AREAS
LIGHT FIXTURES - BACK OF HOUSE
EMERGENCY LIGHTS AND SIDE LIT EXIT SIGNS
LAMPS ON SALES FLOOR
LAMPS AND INSTALLATION OF TRACK FIXTURES
ILLUMINATED SIGNAGE AT STOREFRONT
2" CONDUIT w/ PULL STRING FROM LL'S PHONE CLOSET TO TENANT LAN. ROOM AT 13'-6" A.F.F. MIN.
25 PAIR CAT5E CABLE FROM PHONE CLOSET TO LAN ROOM
SECURITY SYSTEM
DATA AND TELEPHONE SERVICE TO PREMISES
DATA AND TELEPHONE EQUIPMENT
BELL AT EMPLOYEE ENTRANCE
AUDIO/ VISUAL SYSTEM COMPONENTS
SPEAKERS
SPEAKER LOW VOLTAGE WIRING
SANITARY WASTE, DOMESTIC SUPPLY AND VENT PIPES TO PREMISES
WATER METER
SANITARY WASTE, DOMESTIC SUPPLY AND VENT PIPES WITHIN PREMISES
FIXTURES, EQUIPMENT, & ACCESSORIES
FLOOR DRAINS AND WATERPROOF MEMBRANE
SPRINKLER MAIN AND DISTRIBUTION BRANCHES TO PREMISES AT 13-6" A.F.F., MIN.
SPRINKLER BRANCHES DROPS AND HEADS
FIRE ALARM SYSTEM
FIRE EXTINGUISHERS (COORDINATE LOCATIONS W/ FIRE MARSHAL & TENANT REP.)
SMOKE DETECTORS
FINAL CLEAN UP AND MAKE READY FOR OCCUPANCY
CERTIFICATE OF OCCUPANCY
SEE NOTES 1 & 5
FIRE-SAFING AND FIRE-PROOFING
FURNISHED
BY
INSTALLED
BY
RESPONSIBILITY SCHEDULE NOTES
X-RAY SLAB AS REQUIRED
IF REQ'D. - USE LL CONTRACTOR AS REQ'D.
HVAC UNIT(S) & STRUCTURAL SUPPORT (IF REQ'D.)
SMOKE EVACUATION SYSTEM (WHERE APPLICABLE)
ELECTRICAL SERVICE TO PREMISES AT 13'-6" A.F.F. MINIMUM
CONDUIT FOR COPPER FEED FROM LL'S SWITCH GEAR TO TENANT ELEC. ROOM
COPPER FEED FROM LL'S SWITCH GEAR TO TENANTS ELECTRICAL ROOM
FUSIBLE DISCONNECT AND LANDLORD'S SWITCH GEAR
LAN CABINET
ALL PATCH PANELS AND WIRE MANAGEMENT
CONSECUTIVELY LABELED
CONTINUITY TEST REPORT FINISHED TO OWNER
METER
TENANT MAIN DISTRIBUTION "MDP"
(INCLUDING DISPOSAL OF ALL ASSOCIATED CRATING & DEBRIS)
DATA AND COMMUNICATIONS CONDUIT
SEE CONSTRUCTION SHTS.
SEE MECH. DWGS.
AS REQUIRED
G.C. TO COORDINATE, SEE A-600 SERIES SHTS.
SEE MECH. DWGS.
FIRE RATED PAINTED PLYWOOD FOR TECHNOLOGY USE
LOW VOLTAGE SLEEVES AND FIRE STOPPING
PULL STRING IN CONDUITS AS NOTED IN ELECTRICAL DRAWINGS
AS NOTED IN ELECTRICAL SHTS.
COMPLETED CONDUIT PATHWAY SYSTEM FROM UTILITY COMPANY/LL END BOX INTO TEN. SPACE
COMPLETE TECHNOLOGY GROUNDING SYSTEM INCLUDING BUT NOT LTD. TO, GROUND CONDUCTOR,
COPPER BUS BARS & ALL ASSOC. HDWR REQ'D TO COMPLETE GROUNDING SYSTEM.
BONDING OF ALL TECH. EQUIPMENT TO GROUND SYSTEM
FIELD QUALITY CONTROL (TESTING AND CERTIFICATION)
ALL REQUIRED DATA HARDWARE
IDENTIFICATION PRODUCTS
ADMIN OFFICE CABINETS, SHELVING AND MISC. CASEWORK
SEE NOTE 6
SECURITY SYSTEM CONDUIT AS NOTED IN ELECTRICAL DRAWINGS
NEW OPENING IN UPPER LEVEL FLOOR SLAB FOR STAIRS AND ELEVATOR
STRUCTURAL WORK
STAIR FRAMING, ELEVATOR SHAFT, HOIST BEAM & FRAMING FOR LOWER LEVEL EXTENSION
ELEVATOR (CAB, MACHINES AND RELATED EQUIPMENTS)
VERTICAL TRANSPORTATION
ELEVATOR TRANSPORTATION AND PERMITS
STOREFRONT CONSTRUCTION BARRICADE (TAPED, SANDED, AND PAINTED), FITTED WITH DOUBLE DOORS
FLOOR LEVELING (1/4" OVER 10'-0")
SPECIAL INSPECTIONS N/A
INTERIOR BARRICADE PANELS & STANDARDS
H&M GRAPHICS AND WALLPAPER
CUBE DOOR SECURITY SYSTEM (DOOR JAMB)
ALL REQUIRED BLOCKING
USE LL CONTRACTOR AS REQ'D.
USE LL CONTRACTOR AS REQ'D.
USE LL CONTRACTOR AS REQ'D.
USE LL CONTRACTOR AS REQ'D., SEE FP SHTS.
USE LL CONTRACTOR AS REQ'D.
LANDLORD
G.C. TO PATCH & REPAIR AS REQ'D. TO MAINTAIN RATING,
SEE CONSTRUCTION SHTS. PROVIDE GYP. BD. WHEREVER
NOT EXISTING ON TENANT'S SIDE ONLY & FIRE TAPE, CAULK,
AND SEAL AS REQ'D TO ACHIEVE RATING AS NOTED.
TEN.VENDOR
TENANTG.C.
NOT APPLICABLE
NOT APPLICABLE
STOREFRONT SUPPORT AND FRAMING
NOT APPLICABLE
NOT APPLICABLE
CONTROL JTS. AS REQ'D. WHERE APPLICABLE
SALES AREA / FITTING ROOM AREA(S) CERAMIC TILE FLOOR
BACK OF HOUSE VCT FLOOR / CONCRETE
MOTORIZED ROLLING GRILLE AT STOREFRONT ENTRANCE(S)
STOREFRONT FRAMING AT PIERS, CLADDING, ALUM. STOREFRONT SYSTEM AND GLAZING
SOLID CORE WOOD DOORS, FRAMES, AND DOOR HARDWARE
SEE DOOR SCHEDULE ON SHT. A-800
SEE DOOR SCHEDULE ON SHT. A-800
STOCKROOM FIXTURES AND SHELVING
ALL WD. BLOCKING SHALL BE FRT
COORDINATE WITH LL'S REP.
SEE MECH. DWGS.
LL TO PROVIDE PER TENANT'S PLAN
COORD. W/ LL'S REP.
AS BUILT DRAWINGS, AIR BALANCE REPORT AND USER MANUALS
SEE DOOR SCHEDULE ON SHT. A-800
SEE SHT. A-200 AND A-700 SERIES
SEE PLUMBING DRAWINGS FOR MORE INFO.
SEE STRUCTURAL DWGS. FOR MORE INFO.
G.C. TO VERIFY LINEAR FOOTAGE ON DWGS.
G.C. TO VERIFY LINEAR FOOTAGE ON DWGS.
SEE A-600 SHTS. & DOOR SCHEDULE ON SHT. A-800
SEE A-600 SHTS. FOR MORE INFO.
SEE CONSTRUCTION SHTS. FOR MORE INFO.
F/E CABINETS BY GC
NOT APPLICABLE
REFER TO ELEC. SHTS. FOR MORE INFO.
REFER TO ELEC. SHTS. FOR MORE INFO.
REFER TO ELEC. SHTS. FOR MORE INFO.
BARRICADE REMOVAL
TOP OF SLAB TO BE 1/2" LOWER THAN EXISTING FLOORING,
PER LEASE.G.C. TO CONTRACT PSI TO PERFORM LEVELING
TEST PRIOR TO FLOOR INSTALLATION
SEE PLUMBING DRAWINGS FOR MORE INFO.
SPRINKLER SYSTEM SHUTDOWNS AND FIRE ALARM TIE-INS
SHALL BE AT TENANT'S REASONABLE EXPENSE, NOT TO
EXCEED $250.00 PER SHUTDOWN. NOTWITHSTANDING THE
FOREGOING, THE FIRST SHUTDOWN IS FREE. CONSTRUCTION
TRASH AND DEBRIS ARE TO BE REMOVED AT TENANT'S
CONTRACTOR EXPENSE. COORDINATE WITH LANDLORD'S
WORK LETTER.
IF REQUIRED
H&M CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING FULL "AS-BUILT"
CONSTRUCTION DOCUMENTS TO H&M PROJECT ARCHITECT IS DIRECTION UPON
CONSTRUCTION COMPLETION AS A REQUIREMENT FOR PROJECT CLOSE-OUT
PROJECT CLOSE OUT SHOULD OCCUR WITHIN 60-90 DAYS AFTER THE STORE OPENS. FINAL
REQUISITION FOR PAYMENT WILL BE MADE TO THE CONTRACTOR WHEN ALL CLOSE OUT
PAPERWORK IS IN A COMPLETE CLOSE OUT FILE TO INCLUDE;
- SIGNED OFF PUNCH LISTS FROM H&M AND LANDLORD.
- FINAL LIEN WAIVERS FROM G.C. AND ALL SUBCONTRACTORS.
- AS BUILT DRAWINGS
- AIR BALANCE REPORT BY INDEPENDENT AIR BALANCING COMPANY WHICH HAS BEEN
REVIEWED AND APPROVED BY THE PROJECT MECHANICAL ENGINEER.
- CERTIFICATE OF OCCUPANCY AND ALL INSPECTION SIGN OFF CARDS.
- ALL EQUIPMENT OPERATION AND MAINTENANCE MANUALS.
- SWORN STATEMENT OF CONTRACTORS COSTS FORM
- LIST OF ALL SUBCONTRACTORS WITH CONTACT NAMES AND PHONE NUMBERS
- CHANGE ORDER ANALYSIS FORM
- CONTRACTORS CERTIFICATE OF INSURANCE
PROJECT CLOSE OUT
AS BUILT DRAWINGS
LIST OF SUBMITTALS/SHOP
DRAWINGS
1. GENERAL CONTRACTOR AND SUB CONTRACTOR TO PROVIDE SUBMITTALS/ SHOP DWGS. FOR
REVIEW & APPROVALS TO ARCHITECT, TENANT, LANDLORD, DEPT. OF BLDG. AND ALL REQUIRED
AUTHORITIES AND AGENCIES. REFER TO S.M.E.P. DOCUMENTS FOR SPECIFIC SHOP DRAWINGS
REQUIRED FOR THIS PROJECT.
SIGNAGE QUARRYCAST
H.V.A.C. UNITS & CONTROLS INTERIOR WOODWORK (B.O.H. MILLWORK)
DUCT LAYOUT & CONNECTIONS STRUCTURAL STEEL FRAMING
FIRE ALARM STEEL DOORS/ FRAMES
SPRINKLER ROLL UP GRILLES
ACCESS PANEL GLAZING
STOREFRONT ACOUSTICAL CEILING TILE & GRID
ESCALATORS (WHERE APPLICABLE) TOILET COMPARTMENTS
ELEVATORS (WHERE APPLICABLE) STEEL LOCKERS
DOOR HARDWARE TOILET ACCESSORIES
SMOKE BAFFLE CONCRETE MIX
HANDRAILS/ GUARDRAILS REINFORCING BAR
STAIR CALC. FOR PILE DESIGN
BRAKE METAL PLUMBING FIXTURES
RECEPTACLES LIGHTING FIXTURES
ELECTRICAL DISTRIBUTION DISCONNECT/ SWITCHES
DIFFUSERS/ GRILLES
2. G.C. TO SUBMIT CEILING COORDINATION PLAN w/ LOCATION OF ALL DEVICES (LIGHTING, INT.
SIGNAGE, LIT. NAVIGATION, DIFFUSERS, ACCESS PANELS, SPRINKLER HEADS, ETC.) FOR APPROVALS
NOT LIMITED TO THIS LIST
RESPONSIBILITY SCHEDULE
UNLESS OTHERWISE NOTED
VINYL COMPOSITION TILE
V.I.F.
w/
V.C.T.
U.O.N.
T.O.
=
=
=
=
=
S.S.
TEN.
STD.
O.C.
R.U.G.
=
=
=
=
=
VERIFY IN FIELD
WITH
TOP OF
STAINLESS STEEL
ON CENTER
ROLL UP GRILLE
STANDARD
TENANT
N.T.S.
MIR.
=
MIRROR OR MIRRORED
NOT TO SCALE
REF = REFERENCE
SOLID CORE WOOD DOORSC WD =
=
THK. = THICK
MTL. METAL=
PLYWD. PLYWOOD=
SIMILARSIM. =
SHEETSHT. =
REQ'D. = REQUIRED
REQ'TS. = REQUIREMENTS
THICKTHK. =
UNDERSIDEU.S. =
OPP. = OPPOSITE
N.I.C. NOT IN CONTRACT=
P.C. POWDER COAT=
SPECIAL MIRRORSM. =
F.E.
MPSS
TBS
FA
PVM
=
=
=
=
=
NOTE 8 VERIFY PER PROJECT. COORDINATE RESPONSIBILITY WITH " L.L.'S WORK LETTER".
FIRE EXTINGUISHERS
TO BE SCHEDULED
PEOPLE VIEW MONITOR
MIRROR POLISHED STAINLESS STEEL
FIRE ALARM
INTERCOM
(2) SEPARATE SOURCES. GC TO PROVIDE AN
ADDITIONAL 1" CONDUIT
FURNISHED & INSTALLEDF & I =
X FIXTURE TAG
HANDICAPPEDH.C. =
ACCESS PANELS
X
X
X
X
X
FILE CABINETFC =
SAFETY CABINETSC =
3-TIER OR 6-TIER LOCKERLKR =
STOREFRONT SIGNAGE
SALES AREA ALUMINUM CORNER GUARDS SEE FIXTURE SHTS.
SALES AREA SIGNAGE
LIGHTBOXES
SEE A-600 SHTS.
X - X X X
DISCIPLINE DESIGNATOR
(ARCH.,PLUMB., ELEC.,
ETC.)
SHEET TYPE
(CONSTRUCTION
DESCRIPTION)
SEQUENCE NUMBERS
GENERAL OR FLOOR LEVEL
(CELLAR, FIRST FLOOR
SECOND FLOOR, ETC.)
SEQUENCE NUMBERS
(NUMBER OF DRAWINGS
IN SEQUENCE)
*NOTES:
ANY DRAWING THAT IS CHANGED AFTER THE
FIRST ISSUE WILL HAVE A DELTA WITH SEQUENCE
# ( ) AND 'REVISION SEQUENCE' NUMBER WILL
MATCH DELTA #.
DELTA NUMBERS WILL SHOW ON APPLICABLE
REVISED SHEETS IN TITLE BLOCK COLUMN.
IF A DRAWING IS NOT REVISED, BUT PUBLISHED
WITH NEW REVISED SHEET(S), THE REVISION
NUMBER WILL NOT CHANGE ON THAT SHEET
EVEN THOUGH THE NEW REV APPEARS ON THE
TITLE BLOCK COLUMN AT BOTTOM.
SHEET NUMBER
REVISION:
SHEET TITLE:
SPACE NO.:
ARCH PROJECT NO.:
SCALE:
DRAWN BY:
REV. NO:
SHEET NO:
PRODUCT SEASON:
2018
US667-BLUE
BRANSONLANDING
BUILDING1000
SPACENOS.1003-1013
100BRANSONLANDINGBLVD
BRANSON,MOZIP65616
AS NOTED
2018
2187-17
ISSUE DATE:
1003-1013
1 11.06.17 PROTOTYPE UPDATES
D.O.B. NO:
12.18.17 CLIENT/LANDLORD REVIEW
4 6 1 F R O M R O A D
PARAMUS, NJ 07652
973.253.9393 TEL
973.253.9390 FAX
WWW.SARGARCH.COM
VP
A-010
GENERAL NOTES AND
RESPONSIBILITY SCHEDULE
SERVICE AREA
PLACEFOR
MANNEQUINS PLACE FOR
MANNEQUINS
3-TIER
LOCKER
3-TIER
LOCKER
3-TIER
LOCKER
3-TIER
LOCKER
3-TIER
LOCKER
3-TIER
LOCKER
3-TIER
LOCKER
3-TIER
LOCKER
3-TIER
LOCKER
3-TIER
LOCKER
3-TIER
LOCKER
3-TIER
LOCKER
3-TIER
LOCKER
3-TIER
LOCKER
3-TIER
LOCKER
3-TIER
LOCKER
48"X30"
CLR.
30"x48"
RECYCLE VINYL
ON WALL
SAMPLE WALL
42"
ROUND
F
BL.ASH
M
W.ASH
L
WO
WOEND
Girl134-170
WOSTARTWOWOWOWOENDWOSTARTWOWOWOWOEND
WOSTART WO WO WO WO WO WO WO WO WO WO WO WO WO WO WO END
WOSTARTWOWOWOWO
WO STARTWOWOWOWOWOWOWOEND
F
WO WO
WO WO
WOSTART WO WO WO WO WO WO WO END
SE
S E
SE
S E
SESE
SE
SE
SE
W
(LADIES)
SALES AREA
001
(LAD. DIV)
SALES AREA
001
(KIDS)
SALES AREA
001
ROOM #1
STOCK
017
LOUNGE
014
WINDOW #4
POSTER
008
WINDOW #1
POSTER
002
WINDOW
OPEN
003
WINDOW #2
POSTER
004
WINDOW
DISPLAY
005
ENTRY
006
WINDOW #3
POSTER
007
ROOM
ADMIN
009
MTG. RM.
SECURITY
010
HALLWAY
012
CLOSET
JANITOR'S
011
TOILET RM.
WOMEN'S H/C
013
TOILET RM.
MEN'S H/C
015
ROOM
LAN
016
ROOM
ELECTRICAL
018
AREA #1
FITTING RM.
019
ROOM #2
STOCK
020
AREA #2
FITTIN RM.
021
ROOM #3
STOCK
022
WINDOW #5
POSTER
023
(MENS)
SALES AREA
001
NIGHTBOX
REMOTE
024
EX2
EX1
EX1 EX1
EX1
EX2
EX1
EX1
EX1EX1
EX1
EX1
EX1
EX1
EX1
EX2
EX2
EX2
EX2
F.E.2
F.E.2F.E.2
F.E.2
F.E.2
F.E.1
F.E.1
F.E.1
F.E.3
F.E.3
F.E.1
F.E.1
EXTERIOR
F.E.1
F.E.1
F.E.2
EX1
F.E.2
EX2
WO STARTWOWOWOWOWOWOWOEND WO WO STARTWOWOWOEND
WOSTART WO WO WO END
WO WO
WO
A
B
C
D
E
C.3
12345678910
EXTERIOR
EXTERIOR
EXTERIOR
EXTERIOR
MALL SERVICE
CORRIDOR
MALL SERVICE
CORRIDOR
EX1
EX1
EX1
DIAGONAL DISTANCE OF AREA SERVED = 241'-11"
WALL MTD. FIRE
EXTINGUISHER AND
ALL REQUIRED
MOUNTING
EQUIPMENT, SUPPLIED
AND INSTALLED BY
G.C. G.C. TO PROVIDE
F.R. WOOD
BLOCKING AS REQ'D.
FOR PROPER
MOUNTING
NOTE:
G.C. TO VERIFY AND
COORDINATE ALL
LOCATIONS MOUNTING
HEIGHTS AND
REQUIREMENTS OF
EMERGENCY EQUIPMENT
WITH STATE AND LOCAL
CODES.
48"TOEXTINGUISHER
HANDLE(MAX.)
WALL MOUNTED
FIRE EXTINGUISHER
(F.E.1 & F.E.3)
RECHARGEABLE
EMERGENCY
FLASHLIGHT
44"TOCENTERLINE
OFCHARGER&RECEPTACLE
60"MIN.TOBOTTOM
OFSIGN
EMERGENCY
EVACUATION
MAP
LEGEND
EMERGENCY
EVACUATION MAP
SURFACE MOUNTED
EMERGENCY
FLASHLIGHT AND
WALL CHARGER
EQUIPMENT,
FURNISHED AND
INSTALLED BY G.C.
SURFACE MOUNTED
EMERGENCY EVACUATION
MAP WITH BLACK FRAME
(SUPPLIED & INSTALLED BY
G.C.)
SIGN SIZE AND LETTERING TO
MEET ALL STATE AND LOCAL
CODE REQ'TS. LOCATE
ABOVE FIRE EXTINGUISHER.
BRUSHED
STAINLESS STEEL
WALL RECESSED
FIRE EXTINGUISHER
CABINET AND FIRE
EXTINGUISHER
INCLUDING ALL
REQUIRED
MOUNTING
HANGER
EQUIPMENT,
SUPPLIED AND
INSTALLED BY G.C.
48"TOCABINETHANDLE
(HANDLECENTEREDONDOOR)
RECESSED
FIRE EXTINGUISHER
CABINET (F.E.2)
6"
HOLD
OUTLINE OF
SURFACE
MOUNTED
EMERGENCY
EVACUATION
MAP
1. MAINTAIN 3'-8" CLEAR PATH BETWEEN THE EXIT DOORS AT ALL TIMES.
MAINTAIN 3'-0" CLEAR PATH BETWEEN FLOOR FIXTURES.
2. VERIFY EXIT SIGNS COORDINATE W/PATH OF EGRESS. REPORT ANY
DISCREPANCIES TO ARCHITECT / ENGINEER PRIOR TO ROUGH- IN.
3. PER (CODE/SECTION) 'EXIT ACCESS TRAVEL DISTANCE', FOR OCCUPANCY 'M',
TRAVEL DISTANCE NOT TO EXCEED 250 FEET FOR BUILDINGS EQUIPPED
THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE
WITH CODE.
4. EXIT OR EXIT ACCESS DOORWAY ARRANGEMENT: WHERE ACCESS TO THREE
OR MORE EXITS ARE REQ'D., AT LEAST TWO EXIT DOORS OR EXIT ACCESS
DOORWAYS SHALL BE ARRANGED IN ACCORDANCE WITH THE PROVISIONS
OF (CODE/SECTION)
·1/3 DIAG. DISTANCE OF AREA SERVED = 241'-11" / 3 = 80'-7 3/4"
· DISTANCE BETWEEN 2 CLOSEST EXITS = 67'-4"
· EXITS ARE IN COMPLIANCE
*
SYMBOL DESCRIPTION
F.E.1 DENOTES 10 LBS. ABC 10-W. UNIT MOUNTED TO WALL W/
HANGER (NO CABINET). LOCATION OF FIRE EXTINGUISHERS ON
PLAN ARE TENANT'S MINIMUM REQUIREMENTS. G.C. TO SUPPLY &
INSTALL AND SHALL COORDINATE WITH TENANT'S
REPRESENTATIVE AND LOCAL FIRE MARSHAL FOR ADDITIONAL
REQUIRED LOCATIONS.
F.E.2 DENOTES 10 LBS. UNIT IN BRUSHED SS RECESSED CABINET
CENTERED ON RESPECTIVE WALL OR BETWEEN ADJACENT
ELEMENTS.
(SPEC # 128-EL-SG FULLY RECESSED TYPE FROM STRIKE FIRST
CORP WWW.STRIKEFIRSTUSA.COM) LOCATION OF FIRE
EXTINGUISHERS ON PLAN ARE TENANT'S MINIMUM
REQUIREMENTS. G.C. TO PROVIDE & INSTALL AND SHALL
COORDINATE WITH TENANT'S REPRESENTATIVE AND LOCAL FIRE
MARSHAL FOR ADDITIONAL REQUIRED LOCATIONS.
F.E.3 DENOTES 10 LBS. CO2-10BC. UNIT MOUNTED TO WALL W/
HANGER (NO CABINET) (IN LAN AND ELECTRICAL ROOM). (SPEC #
CO2-10 FROM STRIKE FIRST CORP WWW.STRIKEFIRSTUSA.COM)
LOCATION OF FIRE EXTINGUISHERS ON PLAN ARE TENANT'S
MINIMUM REQUIREMENTS. G.C. TO SUPPLY & INSTALL AND SHALL
COORDINATE WITH TENANT'S REPRESENTATIVE AND LOCAL FIRE
MARSHAL FOR ADDITIONAL REQUIRED LOCATIONS.
LOCATION OF EMERGENCY EVACUATION MAP. ARCHITECT TO
PROVIDE MAP, G.C. TO MOUNT IN G.C. PROVIDED BLACK FRAME
(REALSPACE SLIMLINE FRAME, 8-1/2"H X 11"W, CLEAR.) G.C. TO
COORDINATE WITH TENANT'S REP. FOR LOCATIONS. MOUNTED
ABOVE FIRE EXTINGUISHER (WHERE POSSIBLE).
LOCATION OF EMERG. FLASHLIGHT DORCY 41-1032. SUPPLIED
AND INSTALLED BY G.C. SEE DETAIL 3/A110 FOR MOUNTING
HEIGHT. STOCK ROOM, ADMIN ROOM AND SEPARATE VISUAL
ROOM TO RECEIVE FLASHLIGHTS. G.C. TO COORDINATE WITH
TENANT'S REP. FOR ADDITIONAL LOCATIONS.
44" MIN. WIDE ACCESSIBLE MEANS OF EGRESS PATH
EXIT POINT OF EGRESS PATH
START POINT OF TRAVEL
EXIT SIGNS, WALL / CELING MOUNTED (ARROW REPRESENTS
DIRECTIONAL SIGN), TACTILE EXIT SIGNS TO BE PROVIDED BY G.C.
AS REQUIRED PER LOCAL AHJ; SEE RCP SHTS.
SAFE AREA DOOR SECURING DEVICE, BARRACUDA BY
GLOABLINDUSTRIAL.COM. REFER TO DOOR SCHEDULE SHT. FOR
MORE INFO.
F.E. 2
F.E. 1
F.E. 3
1. G.C. TO INSTALL FIRE EXTINGUISHERS AS NOTED, BUT NOT LIMITED TO, THE
FOLLOWING LOCATIONS (VERIFY W/ AHJ);
· ALL OFFICES
· ELECTRICAL ROOM
· LAN ROOM
· STOCKROOM
· EMERGENCY EXIT PERIMETER DOOR
· ALL CASHPOINTS
· FITTING ROOM AREA
· ALL DEPARTMENTS WITHOUT A CASHPOINT OR FITTING ROOM
2. FIRE EXTINGUISHERS IN LAN AND ELECTRICAL ROOM TO BE CO2 TYPE.
3. G.C. TO INSTALL TENANT PROVIDED EMERGENCY EVACUATION MAP
INDICATING ALL
EXITS AND EQUIPMENT (FIRE EXTINGUISHER, PULL STATION FIRE HOSE, ETC.)
POSTED
AS REQUIRED, ABOVE FIRE EXTINGUISHERS WHERE POSSIBLE. SEE PLAN FOR
LOCATIONS.
NOTE:
REFER TO MANUF. INSTALLATION
RECOMMENDATIONS FOR ATTACHMENT TO WALL.
FIRE EXTINGUISHER CABINET BY 'STRIKE FIRST' OR
APPROVED EQUAL.
8"
REQ'D.WALL
OPENING
DEPTH
OUTSIDE
DIMENSIONS
11-1/2"x25"
INSIDE
DIMENSIONS
10-1/2" x 24" x 6"
LOCATION FUNCTION OF SPACE AREA (S.F.)
OCCUPANT
LOAD (PERSONS)
MULTIPLIER
(PER CODE/
SECTION)
EGRESS WIDTH
REQUIRED
(INCHES)
EGRESS WIDTH
PROVIDED
(INCHES)
SALES AREA
(GRADE FLOOR) +
DISPLAY/POSTER
WINDOWS +
OFFICE
AREAS/SUPPORT +
TOILET ROOMS:
MERCANTILE 19544 19544 / 60 = 326 66.6"
(44" MIN. FOR EGRESS
PATH PROVIDED
36" MIN. FOR AISLE
WIDTH PROVIDED, SEE
SHEET A-000)
202" (FOR (2) EXITS
FROM SALES AREA
AND (1) EXITS FROM
BACK OF HOUSE
AREA)STOCK ROOM +
VISUAL ROOM +
NIGHT BOX
STORAGE 2003 2003 / 300 = 7
TOTAL
TWO EXITS REQ'D. PER
(CODE) 21547 333 0.2
LOCATION TRAVEL PATH MAXIMUM TRAVEL DISTANCE
SALES AREA
EXIT ACCESS
POINT A TO EXIT 1
POINT A TO EXIT 2
POINT B TO EXIT 2
POINT C TO EXIT 1
POINT C TO EXIT 2
POINT E TO EXIT 1
POINT D TO EXIT 1
POINT D TO EXIT 2
POINT E TO EXIT 2
164'-1"
242'-1"
POINT F TO EXIT 1
POINT G TO EXIT 2
POINT H TO EXIT 1
POINT G TO EXIT 2
BOH / STOCK
ROOM
EXIT ACCESS
155'-11"
110'-3"
101'-7"
193'-8"
115'-2"
165'-7"
243'-7"
180'-10"
127'-1"
165'-6"
177'-9"
90'-7"
131'-11"
POINT H TO EXIT 2
LOUNGE
EXIT ACCESS
98'-9"
POINT I TO EXIT 3
BOH
EXIT ACCESS
51'-9"
EGRESS PLAN LEGEND
EXIT TRAVEL DISTANCE
EGRESS NOTES FIRE EXTINGUISHER NOTES
OCCUPANCY LOAD, EXITS, & EGRESS WIDTH CALCULATIONS
PT. 'A'
PT. 'F'
PT. 'E'
PT. 'G'
PT. 'C'
PT. 'J'
PT. 'D'
PT. 'I'
PT. 'H'
PT. 'B'
*
*
*
EXIT '1'
EXIT '2'
EXIT '3'
POINT B TO EXIT 1
POINT J TO EXIT 1
POINT J TO EXIT 2
135'-1"
3'-8"
TYP.
3'-8"
TYP.
3'-8"
TYP.
3'-8"
TYP.
3'-8"
TYP.
3'-8"
TYP.
3'-8"
TYP.
3'-8"
TYP.
3'-8"
TYP.
3'-8"
TYP.
3'-8"
TYP.
3'-8"
TYP.
3'-8"
TYP.
3'-8"
TYP.
3'-8"
TYP.
3'-8"
TYP.
3'-8"
TYP.
3'-8"
TYP.
3'-8"
TYP.
3'-8"
TYP.
* EXIT '4'
PT. 'L'
POINT L TO EXIT 4
REMOTE
NIGHT BOX
30'-7"
REVISION:
SHEET TITLE:
SPACE NO.:
ARCH PROJECT NO.:
SCALE:
DRAWN BY:
REV. NO:
SHEET NO:
PRODUCT SEASON:
2018
US667-BLUE
BRANSONLANDING
BUILDING1000
SPACENOS.1003-1013
100BRANSONLANDINGBLVD
BRANSON,MOZIP65616
AS NOTED
2018
2187-17
ISSUE DATE:
1003-1013
D.O.B. NO:
12.18.17 CLIENT/LANDLORD REVIEW
4 6 1 F R O M R O A D
PARAMUS, NJ 07652
973.253.9393 TEL
973.253.9390 FAX
WWW.SARGARCH.COM
EGRESS PLAN 1
SCALE: 1/8" = 1'-0"
EGRESS PLAN (REMOTE NIGHTBOX) 2
SCALE: 1/8" = 1'-0"
NORTH
LIFE SAFETY EQUIPMENT MOUNTING HEIGHTS 3
SCALE: N.T.S.
MH/VM
A-110
EGRESS PLANS
3-TIER
LOCKER
3-TIER
LOCKER
3-TIER
LOCKER
3-TIER
LOCKER
3-TIER
LOCKER
3-TIER
LOCKER
3-TIER
LOCKER
3-TIER
LOCKER
3-TIER
LOCKER
3-TIER
LOCKER
3-TIER
LOCKER
3-TIER
LOCKER
3-TIER
LOCKER
3-TIER
LOCKER
3-TIER
LOCKER
3-TIER
LOCKER
48"X30"
CLR.
30"x48"
42"
ROUND
F
WO
WOEND
WOSTARTWOWOWOWOENDWOSTARTWOWOWOWOEND
WOSTART WO WO WO WO WO WO WO WO WO WO WO WO WO WO WO END
WOSTARTWOWOWOWO
WO STARTWOWOWOWOWOWOWOEND
WO WO
WO WO
WOSTART WO WO WO WO WO WO WO END
SE
S E
SE
S E
SESE
SE
SE
SE
W
(LADIES)
SALES AREA
001
(LAD. DIV)
SALES AREA
001
(KIDS)
SALES AREA
001
ROOM #1
STOCK
017
LOUNGE
014
WINDOW #4
POSTER
008
WINDOW #1
POSTER
002
WINDOW
OPEN
003
WINDOW #2
POSTER
004
WINDOW
DISPLAY
005
ENTRY
006
WINDOW #3
POSTER
007
ROOM
ADMIN
009
MTG. RM.
SECURITY
010
HALLWAY
012
CLOSET
JANITOR'S
011
TOILET RM.
WOMEN'S H/C
013
TOILET RM.
MEN'S H/C
015
ROOM
LAN
016
ROOM
ELECTRICAL
018
AREA #1
FITTING RM.
019
ROOM #2
STOCK
020
AREA #2
FITTIN RM.
021
ROOM #3
STOCK
022
WINDOW #5
POSTER
023
(MENS)
SALES AREA
001
NIGHTBOX
REMOTE
024
EXTERIOR
WO STARTWOWOWOWOWOWOWOEND WO WO STARTWOWOWOEND
WOSTART WO WO WO END
WO WO
WO
A
B
C
D
E
C.3
12345678910
EXTERIOR
EXTERIOR
EXTERIOR
EXTERIOR
MALL SERVICE
CORRIDOR
MALL SERVICE
CORRIDOR
SYMBOL DESCRIPTION
PARTITION TYPE -
REFER TO SHEET PARTITION TYPES SHEET
DOOR NUMBER -
REFER TO DOOR SCHEDULE SHEET
ELEVATION TAG
DETAIL TAG
CONSTRUCTION TAG NOTE
X
X
X
XX
X
XX
X
SYMBOL DESCRIPTION
EXISTING PARTITION TO REMAIN:
PATCH & REPAIR AS REQ'D TO "LIKE NEW" CONDITION &
MAINTAIN EXISTING RATING
NEW NON-RATED PARTITION:
REFER TO WALL TAG FOR PARTITION TYPE
NEW RATED PARTITION (U#465):
REFER TO CONSTRUCTION PLAN FOR PARTITION TYPE;
FIRE SEAL TOP OF PARTITION & ALL PENETRATIONS TO
MAINTAIN FIRE RATING & PROVIDE FRT PLYWOOD ON
WALLS AS REQ'D
NEW NON-RATED SECURITY PARTITION:
REFER TO CONSTRUCTION PLAN FOR PARTITION TYPE;
5/8" TYPE 'X' GYP. BD. ON BOH ADJACENT SIDE TO U.S.
OF STRUCTURE ABOVE.
NEW WALL INFILL:
NEW INFILL TO MATCH AND ALIGN WITH EXISTING
CONSTRUCTION / FINISHES (U.O.N.) G.C. MATCH
EXISTING WALL RATING TO MAINTAIN FIRE RATING AS
APPLICABLE.
NOTE:
REFER TO SHT. A-211 FOR DIMENSION PLAN.
NOTE:
REFER TO SHT. A-212 FOR CONSTRUCTION KEY AND GENERAL NOTES.
1. GYPSUM BOARD FINISH MUST BE LEVEL (5) FOR ALL PARTITIONS.
2. GYPSUM BOARD FINISH MUST BE LEVEL (5) FOR ALL CEILING CONSTRUCTION.
3. G.C. TO PROVIDE (1) HOUR FIRE RATING (MIN.) INCLUDING DOORS AT ALL
RATED WALLS SHOWN ON CONSTRUCTION PLAN.
NOTE: PARTITION SEPARATING SALES FROM BACK OF HOUSE/ STOCK ROOM
SHOULD BE (1) HOUR FIRE RATED WALLS (MIN.)
SYMBOL LEGEND
WALL LEGEND F&I BY G.C. (U.O.N)
NOTES:
101
102
124
125
104
108 109 110
127
111
112
113
114
115
102
103
123B
123A
122
121120
119
118
118
118
107
106
105
128
3
A-610
2
A-610
1
A-610
4
A-610
3
A-611
2
A-611
1
A-611
4
A-611
3
A-612
2
A-612
1
A-612
4
A-612
3
A-613
2
A-613
1
A-613
4
A-613
B
B
B
B1 B C B1
B
B
B
B
B1
B
A A B
B
B
B
B
B B B B
B
B
B
B1
B1
B
B
B B
B
A A
B B
B
BBB
B
B
D
D
D
D
D
D
D D
D TYP.,
ALL SIDES
D TYP.,
ALL SIDES
D TYP.,
ALL SIDES
D TYP.,
ALL SIDES
G1
G1
G1G1
GG
GG
G TYP.,
ALL SIDES
G TYP.,
ALL SIDES
G1G1
G1
G1
M4
M1
M1 M3 M3M3
M3M3
M3
M1 M2M2
M2
M2
M2
M3M3
M3
M3M3
M4
H
M3
M3M3
L1L1
L1L1
L1
G1G1
G GG
GG1
G
EE
E2
E E
K
K4KK
K4
K
KK
L1
K3K3K3H HH
J1
JJJ
E1E1 E1E1
F
F
E
E
F
EE EE
F E
FE E E
E
F FE EE
HL
H
H
TYP.
A-711
1
TYP.
A-711
1
TYP.
A-711
1
TYP.
A-711
1
A-740
1
A-743
1
A-730
1
A-730
6
A-740
2
A-702
1
1
A-600
3
A-600
A-600
2/4 1 11
1 1
1
1
1
1
1
1
1
3333 3 3 3 3
3 4
5
777 7 7
7
8 8 8 8 8 8
8
8
9 9
9
9
9 9 91111 11 1111
11
11
11
12
12
14 14
14
14
14
14
15
15
1515
16
161616
16
16 18
1818
18
18
18 19 19
19
20
20
20
21
21
21
21
21 22
2221 22
22
22
22
23
23
23
23
23
23
24
24 25
2525
25
25
25
26 26
26
2629 29 29
29
31
32
33
34
35
35 36
36 37
37
38
38
39
39
40 40
41
41
41
41 41 41
42
42
42
27
30
44
45
45
46
47
47
48
48 49
50
53
1
56
19
27
27
56
LA-743
12
56
M3
M6
G1
51 52
24 42
27
27
20
12
E
E
126
M2
39
E
E
31
ALIGN
4
6
6
20
24
12
12
ALIGNALIGN
E
E
20
ALIGN
1127
C
M
REVISION:
SHEET TITLE:
SPACE NO.:
ARCH PROJECT NO.:
SCALE:
DRAWN BY:
REV. NO:
SHEET NO:
PRODUCT SEASON:
2018
US667-BLUE
BRANSONLANDING
BUILDING1000
SPACENOS.1003-1013
100BRANSONLANDINGBLVD
BRANSON,MOZIP65616
AS NOTED
2018
2187-17
ISSUE DATE:
1003-1013
D.O.B. NO:
12.18.17 CLIENT/LANDLORD REVIEW
4 6 1 F R O M R O A D
PARAMUS, NJ 07652
973.253.9393 TEL
973.253.9390 FAX
WWW.SARGARCH.COM
CONSTRUCTION PLAN 1
SCALE: 1/8" = 1'-0"
CONSTRUCTION PLAN - REMOTE NIGHTBOX 2
SCALE: 1/8" = 1'-0"
NORTH
MH
A-210
CONSTRUCTION PLANS
3-TIER
LOCKER
3-TIER
LOCKER
3-TIER
LOCKER
3-TIER
LOCKER
3-TIER
LOCKER
3-TIER
LOCKER
3-TIER
LOCKER
3-TIER
LOCKER
3-TIER
LOCKER
3-TIER
LOCKER
3-TIER
LOCKER
3-TIER
LOCKER
3-TIER
LOCKER
3-TIER
LOCKER
3-TIER
LOCKER
3-TIER
LOCKER
48"X30"
CLR.
30"x48"
42"
ROUND
F
WO
WOEND
WOSTARTWOWOWOWOENDWOSTARTWOWOWOWOEND
WOSTART WO WO WO WO WO WO WO WO WO WO WO WO WO WO WO END
WOSTARTWOWOWOWO
WO STARTWOWOWOWOWOWOWOEND
WO WO
WO WO
WOSTART WO WO WO WO WO WO WO END
SE
S E
SE
S E
SESE
SE
SE
SE
W
(LADIES)
SALES AREA
001
(LAD. DIV)
SALES AREA
001
(KIDS)
SALES AREA
001
ROOM #1
STOCK
017
LOUNGE
014
WINDOW #4
POSTER
008
WINDOW #1
POSTER
002
WINDOW
OPEN
003
WINDOW #2
POSTER
004
WINDOW
DISPLAY
005
ENTRY
006
WINDOW #3
POSTER
007
ROOM
ADMIN
009
MTG. RM.
SECURITY
010
HALLWAY
012
CLOSET
JANITOR'S
011
TOILET RM.
WOMEN'S H/C
013
TOILET RM.
MEN'S H/C
015
ROOM
LAN
016
ROOM
ELECTRICAL
018
AREA #1
FITTING RM.
019
ROOM #2
STOCK
020
AREA #2
FITTIN RM.
021
ROOM #3
STOCK
022
WINDOW #5
POSTER
023
(MENS)
SALES AREA
001
NIGHTBOX
REMOTE
024
EXTERIOR
WO STARTWOWOWOWOWOWOWOEND WO WO STARTWOWOWOEND
WOSTART WO WO WO END
WO WO
WO
A
B
C
D
E
C.3
12345678910
EXTERIOR
EXTERIOR
EXTERIOR
EXTERIOR
MALL SERVICE
CORRIDOR
MALL SERVICE
CORRIDOR
±30'-0"
(V.I.F.)
±30'-0"
(V.I.F.)
±30'-0"
(V.I.F.)
±30'-0"
(V.I.F.)
±30'-0"
(V.I.F.)
±25'-0"
(V.I.F.)
±30'-0"
(V.I.F.)
±30'-0"
(V.I.F.)
±15'-0"
(V.I.F.)
±30'-0"
(V.I.F.)
±19'-2"
(V.I.F.)
±10'-10"
(V.I.F.)
±30'-0"
(V.I.F.)
±14'-11"
(V.I.F.)
±143'-93
8"
LEASE LINE DIMENSION
±25'-91
8"
LEASE LINE DIMENSION
±74'-81
2"
LEASELINEDIMENSION
±257'-95
8"
LEASE LINE DIMENSION
±61'-21
8"
LEASELINEDIMENSION
±39'-115
8"
LEASE LINE DIMENSION
±16'-15
8"
LEASE LINE DIMENSION
±6'-27
8"
LEASE LINE DIMENSION
±4'-61
2"
LEASE LINE DIMENSION
±11'-4 1
8 "
LEASE LINE DIMENSION
±11'-47
8
"
LEASELINEDIMENSION
±6'-27
8"
LEASELINEDIMENSION
±15'-9"
LEASELINEDIMENSION
±28'-61
8"
LEASELINEDIMENSION
±5'-0
5
8
"
LEASE LINE DIMENSION
15'-21
2"3'-61
4" 8'-63
4" 17'-101
2" 7'-111
2" 26'-13
4" 3'-113
4" 26'-01
8" 8'-07
8" EQ. 3'-107
8" 22'-23
8" 7'-91
2" 22'-25
8" 7'-105
8" 25'-71
4" 4'-4" 21'-0" 3'-31
2"
2'-85
8" 16'-43
4"
(9) WC
2'-33
4" 10'-71
4" 2'-4" 6'-13
4"
(4) WC
2'-87
8"2'-3"16'-47
8"
(9) WC
4'-101
8"
6'-17
8"
(4)WC
2'-13
4"93
8"4'-17
8"8'-41
2"2'-41
8"8'-23
8"
(5)WC
4'-83
8"
4'-33
4" 12'-35
8"
(7) WC
2'-31
2" 2'-1" 32'-97
8"
(17) WC
2'-11
4" 10'-71
4" 2'-13
8" 6'-13
4"
(4) WC
3'-01
2"
6'-33
4"
3'-37
8"8'-23
8"
(5)WC4'-43
8"
3'-65
8" 4'-11
4" EQ. 8'-75
8" EQ. 18'-51
2"
(10) WC
EQ. 8'-75
8" EQ. 4'-11
4" 3'-91
4"
4'-57
8"6'-17
8"
(4)WC
2'-27
8"2'-23
4"8'-23
8"
(5)WC
2'-61
2"8'-75
8"2'-63
4"6'-17
8"
(4)WC
2'-27
8"51
8"8'-75
8"2'-23
4"2'-05
8"
(2)WC
3'-61
2"
4'-81
8"1'-105
8"2'-67
8"16'-47
8"
(9) WC
3'-105
8"
5'-05
8"8'-23
8"
(5)WC
3'-75
8"8'-23
8"
(5)WC
2'-103
4"3'-71
2"23'-93
8"2'-27
8"18'-51
2"
(10)WC
3'-111
4"
2'-13
8"6'-17
8"
(4)WC
3'-35
8"
2'-51
8" 6'-17
8"
(4) WC
2'-23
8" 8'-71
2" 2'-23
8" 4'-11
4"
(3) WC
2'-23
8" 7'-6" 2'-1" 6'-17
8"
(4) WC
3'-71
8"
4'-2"
4'-17
8"
(3)WC
2'-21
2"
2'-7" 6'-17
8"
(4) WC
4'-10"
3'-93
4"6'-17
8"
(4)WC
2'-27
8"2'-27
8"6'-17
8"
(4)WC
3'-83
4"
3'-9"6'-17
8"
(4) WC
2'-27
8"2'-25
8"8'-23
8"
(5) WC
2'-31
8"8'-75
8"71
2"2'-31
4"10'-3"
(6) WC
4'-41
8"
3'-57
8"4'-11
4"
(3)WC
2'-27
8"
3'-43
8" 30'-91
8"
(16) WC
1'-23
4"
1'-27
8"8'-23
8"
(5)WC
2'-5"
111
4" 6'-17
8"
(4) WC
3'-9"
2'-07
8"38'-111
2"
(20)WC
1'-53
4"83
8"4'-11
4"
(3)WC
3'-37
8"
2'-65
8"45'-13
8"
(23) WC
97
8"57
8"
10'-3"
(6) WC
1'-21
8"
2'-33
4"
12'-35
8"
(7)WC
113
8"
22'-77
8"
12'-87
8"
5'-10"
31'-07
8"
7'-01
2"
4'-51
8"4'-51
8"
10'-11
2"
1'-105
8" 2'-61
2"
13'-83
8"
10'-11"
18'-107
8" 4'-111
8" 63'-1"
39'-31
8"
86'-01
4" 1'-33
4" 60'-01
2" 1'-33
4" 66'-11
2"
24'-73
4" 22'-31
8" 13'-15
8"
101'-101
8"
60'-01
2" 1'-33
4" 66'-11
2" 1'-37
8"
127'-55
8"
16'-101
2"15'-11
8"63'-2"
214'-95
8"
16'-101
2"16'-47
8"9'-21
8"
42'-53
8"
113
8"4'-11
4"
(3)WC
2'-93
4"
35'-41
4" 5'-103
8" 13'-77
8" 12'-13
4"
29'-107
8"1'-33
4"53'-43
4"
2'-81
4"
2'-81
4"
2'-81
4"
2'-81
4"
2'-81
4"
2'-81
4"
2'-81
4"
2'-81
4"
2'-81
4"
2'-81
4"
2'-81
4"
2'-81
4"
2'-81
4"
2'-81
4"
2'-81
4"
2'-81
4"
2'-81
4"
2'-81
4"
2'-81
4"
2'-81
4"
2'-81
4"
2'-81
4"
2'-81
4"
2'-81
4"
2'-81
4"
2'-81
4"
2'-81
4"
2'-81
4"
20'-93
8"
13'-11
8"
8'-01
8"
4'-51
8"
8'-55
8" 7'-01
2"
6'-47
8"
3'-43
4"
3'-3"
3'-5"
6'-31
8"
2'-31
8"
1'-71
8"
17'-101
2"
EQ. EQ.
3'-101
2"
6'-91
2"
5'-71
4"
13'-25
8"
2'-17
8"
4'-05
8"
5'-81
8"
3'-33
8"
6'-15
8"
(4) WC
6'-5"
7'-10" 111
2"
11'-07
8"
2'-1"5'-67
8"3'-13
8"
1'-41
8"
3'-31
4" 2'-01
8"
2'-01
8"
3'-37
8"
3'-7"
14'-11
2"
LEASELINEDIMENSIONS
25'-2"
LEASE LINE DIMENSIONS
2'-57
8"
CLOF
CASHWRAP
CLOF
LIGHTBOX
6'-0" 6'-0"EQ. EQ.
5'-10" 5'-10"3'-7"EQ. EQ.
REVISION:
SHEET TITLE:
SPACE NO.:
ARCH PROJECT NO.:
SCALE:
DRAWN BY:
REV. NO:
SHEET NO:
PRODUCT SEASON:
2018
US667-BLUE
BRANSONLANDING
BUILDING1000
SPACENOS.1003-1013
100BRANSONLANDINGBLVD
BRANSON,MOZIP65616
AS NOTED
2018
2187-17
ISSUE DATE:
1003-1013
D.O.B. NO:
12.18.17 CLIENT/LANDLORD REVIEW
4 6 1 F R O M R O A D
PARAMUS, NJ 07652
973.253.9393 TEL
973.253.9390 FAX
WWW.SARGARCH.COM
DIMENSION PLAN 1
SCALE: 1/8" = 1'-0"
NORTH
DIMENSION PLAN - REMOTE NIGHTBOX 2
SCALE: 1/8" = 1'-0"
NOTE:
REFER TO SHT. A-212 FOR CONSTRUCTION KEY AND GENERAL NOTES.
REFER TO SHT. A-740 FOR BOH DIMENSIONS
SYMBOL DESCRIPTION
SM/CM
SPECIAL MIRROR/CLEAR MIRROR. SEE COLUMN
ENCLOSURE SHTS. & FITTING ROOM SHTS. FOR MORE
INFO.
WC. WALL CHANNEL.
RC. RECESSED CHANNEL
ABBREVIATION LEGEND
MH
A-211
DIMENSION PLANS
REVISION:
SHEET TITLE:
SPACE NO.:
ARCH PROJECT NO.:
SCALE:
DRAWN BY:
REV. NO:
SHEET NO:
PRODUCT SEASON:
2018
US667-BLUE
BRANSONLANDING
BUILDING1000
SPACENOS.1003-1013
100BRANSONLANDINGBLVD
BRANSON,MOZIP65616
AS NOTED
2018
2187-17
ISSUE DATE:
1003-1013
D.O.B. NO:
12.18.17 CLIENT/LANDLORD REVIEW
4 6 1 F R O M R O A D
PARAMUS, NJ 07652
973.253.9393 TEL
973.253.9390 FAX
WWW.SARGARCH.COM
1. G.C. IS RESPONSIBLE TO FIELD-VERIFY ALL EXISTING CONDITIONS &
DIMENSIONS IN THE SPACE. FAILURE TO PROPERLY VERIFY EXISTING
CONDITIONS DOES NOT RELIEVE G.C. OF ANY EXPENSES OR
RESPONSIBILITIES RESULTING FROM THAT FAILURE.
2. CONTRACTOR TO PROVIDE PARTITION LAYOUT FOR ARCHITECT'S/ H&M'S
APPROVAL BEFORE CONSTRUCTION FOR CONFIRMATION OF ALL
DIMENSIONS. G.C. TO COORDINATE ALL DIMENSIONS WITH H&M
FIXTURE DIMENSIONS.
3. SEE FITTING ROOM ENLARGED PLANS, ELEVATIONS, & DETAILS SHEET FOR
FITTING ROOM LAYOUT.
4. G.C. TO PROVIDE SHOP DRAWINGS FOR ARCHITECT'S APPROVAL BEFORE
FABRICATION OF ALL FINISHES, HARDWARE & COMPONENTS. SEE SHOP
DWG. LIST ON GENERAL NOTES & RESPONSIBILITY SCHEDULE SHEET.
5. IN CASE OF DISCREPANCY BETWEEN ARCHITECT'S & ENGINEER'S
DRAWINGS, THE MORE STRINGENT, HIGHER QUANTITY OR HIGHER
QUALITY SHALL PREVAIL. CONTRACTOR TO INFORM ARCHITECT & H&M
PROJECT MANAGER OF ANY DISCREPANCIES PRIOR TO SUBMITTING BID.
6. G.C. TO VERIFY ALL DIMENSIONS OF MILLWORK, FIXTURES & FITTING
ROOMS WITH H&M PRIOR TO LAYOUT.
7. G.C. TO PATCH, REPAIR AS REQUIRED & PAINT ALL GYP. BD. COLUMN
WRAPS & EXPOSED AREAS AT EXISTING WINDOW WALLS & ALL
EXISTING GYP. BD.
8. G.C. TO COORDINATE CONSTRUCTION TIMING WITH H&M SCHEDULE
PRIOR TO CONSTRUCTION START. ANY CHANGE TO CONSTRUCTION
SCHEDULE MUST BE SENT TO H&M PM FOR REVIEW & APPROVAL.
9. ALL PLYWOOD BACKING/BLOCKING IS FIRE RESISTANT (F.R.) / FIRE
RETARDANT TREATED (FRT).
10. G.C. IS RESPONSIBLE FOR PROVIDING ALL BRACING /BLOCKING AS
REQUIRED BY CODE & STRUCTURAL NECESSITY FOR ALL FIXTURES AFFIXED
TO WALLS AND CEILINGS. SEE FIXTURE DETAILS & PARTITION TYPES FOR
CONNECTION DETAILS.
11. SEE MEP DRAWINGS FOR ADDITIONAL NOTES.
12. ALL WORK TO COMPLY WITH ALL APPLICABLE LOCAL, STATE & FEDERAL
BY-LAWS & CODE REQUIREMENTS.
13. G.C. TO PROTECT & MAINTAIN EXISTING FIRE PROOFING AROUND
COLUMN & BEAMS & ALL STRUCTURAL MEMBERS TYPICAL THROUGHOUT.
REPAIR/REPLACE ANY DAMAGED FIREPROOFING AS REQ'D. DUE TO
CONSTRUCTION.
14. EXISTING STRUCTURAL SLAB SHALL NOT BE TRENCHED, CUT OR DAMAGED
IN ANY WAY WITHOUT WRITTEN DIRECTION FROM STRUCTURAL E.O.R. &
APPROVAL BY THE LANDLORD.
15. COORDINATE EXACT SAFE LOCATION WITH H&M. G.C. TO PROVIDE
NECESSARY SUPPORT FOR SAFE.
16. G.C. TO PROVIDE ALL NECESSARY SIGNS (INCL. THOSE PER CODE FOR
ACCESSIBILITY) FOR TOILETS, FITTING ROOMS, STAIRS, ELEVATORS (AS
REQ'D.).
17. G.C. TO PROVIDE ALL BOH CORNER GUARDS.
18. G.C. IS SOLELY RESPONSIBLE TO TEST MOISTURE CONTENT OF
SUB-FLOOR PRIOR TO INSTALLATION OF ALL FINISH FLOORING
MATERIALS & MAINTAIN PROPER TEMPERATURE & HUMIDITY LEVELS PER
MANUFACTURERS SPECIFICATIONS.
19. H&M ELEVATOR IS NOT TO BE UTILIZED BY G.C. FOR ANY PURPOSES.
20. NOTHING IS PERMITTED TO ATTACH TO, SUSPENDED FROM, OR
PENETRATE ROOF DECK. G.C. MAY ONLY ATTACH TO TOP CHORD OF
JOIST(S) OR I-BEAMS PER LANDLORD REQUIREMENT. ALL
WALL/CLG./OVERHEAD CONSTRUCTION TO BE SUPPORTED IN THIS
MANNER. NO WELDING OR SHOOTING INTO STRUCTURE IS PERMITTED.
COORDINATE EXTENT OF EXACT REQUIREMENTS WITH LANDLORD'S REP.
21. STRUCTURAL REINFORCING DETAILS TO BE PROVIDED BY A REGISTERED
STRUCTURAL ENGINEER TO LANDLORD FOR APPROVAL AS WELL AS FOR
COORDINATION OF EQUIPMENT SUPPORT OR SUSPENSION, SERVICE
PLATFORMS, DECK PENETRATIONS, ETC. (AS REQ'D.)
22. ANY LANDLORD EQUIPMENT OR COMPONENT EXISTING IN THE SPACE
MUST REMAIN VISIBLE & ACCESSIBLE. G.C. TO COORD. ANY REQ'D
ACCESS W/H&M PM, LANDLORD REP. & ARCHITECT.
23. ALL CONCRETE PATCHING MUST BE LEVEL WITH EXISTING CONCRETE
FLOOR.
24. G.C. TO COORDINATE ALL RATED WALLS WITH M.E.P. DRAWINGS.
PROVIDE FIRE &/OR FIRE/SMOKE DAMPERS &/OR FIRE CAULKING (AS
REQ'D.).
25. G.C. TO INSTALL ALL ELECTRICAL DEVICES & EQUIPMENT AT CENTERLINE
OF COLUMN FACE, TYP., U.O.N.
26. DO NOT SCALE THESE DRAWINGS. USE WRITTEN DIMENSIONS ONLY.
SUBMIT TO ARCHITECT ANY DISCREPANCIES FOR CLARIFICATION. REFER
TO RESPONSIBILITY SCHEDULE.
27. PROVIDE ACCESSIBILITY FOR PHYSICALLY HANDICAPPED PER (APPLICABLE
ACCESSIBILITY CODE).
28. G.C. TO ENSURE ALL INTERIOR WALL BLOCKING IS INSTALLED PRIOR TO
APPLYING WALL FINISHES. COORDINATE LOCATION OF BLOCKING WITH
H&M FIXTURE MANUFACTURERS.
29. NEW STOREFRONT GLAZING TO BE TEMPERED SAFETY GLASS. ALL EDGES
MUST BE GROUND & POLISHED.
30. ALL FLOOR ELECTRICAL BOXES TO BE INSTALLED FLUSH W/ NEW
FLOORING AT CASHWRAP & FIXTURES W/ POWER AS SHOWN ON
ELECTRICAL SHEETS. REFER TO FLOOR & MISC. DETAILS SHEET &
ELECTRICAL DRAWINGS.
31. G.C. TO VERIFY ALL COLUMN LOCATIONS & CONDITIONS. NOTIFY
ARCHITECT OF ANY DISCREPANCIES. ALL GYP. BD. SURFACES TO BE A
LEVEL 5 FINISH PRIOR TO PAINTING.
32. SAW CUTTING (ALLOWED IN SLAB-ON-GROUND CONDITIONS ONLY) &
CORE DRILLING MUST OCCUR OUTSIDE OF MALL OPERATING HOURS.
COORD. W/ MALL'S REP.
33. ALL FLOOR PENETRATIONS MUST BE SLEEVED & SEALED LIQUID TIGHT.
FIRE-STOPPING IS REQUIRED USING APPROPRIATE UL METHOD.
34. G.C. TO FIREPROOF ALL NEW STRUCTURAL ELEMENTS TO INCLUDE BUT
NOT LIMITED TO BEAMS, JOISTS, COLUMNS, ETC. AS REQ'D. PER LL OR
GOVERNING CODE. G.C. TO MATCH NEW FIREPROOFING WITH
EXISTING.
35. G.C. TO VERIFY ALL DIMENSIONS OF MILLWORK, FIXTURES, AND FITTING
ROOMS WITH H&M PRIOR TO LAYOUT INCLUDING BUT NOT LIMITED TO
BLOCKING HEIGHTS.
36. ALL PLYWOOD BACKING/BLOCKING IS FIRE RESISTANT. G.C.
RESPONSIBLE FOR PROVIDING ALL BRACINGS/BLOCKING REQUIRED BY
CODE AND STRUCTURAL NECESSITY FOR ALL FIXTURES, SIGNAGE,
LIGHTING, ETC. AFFIXED TO WALLS AND CEILINGS. ALL EXPOSED HOOD
TRIM IS NOT REQUIRED TO BE FRT
37. COORDINATE WITH MECHANICAL DRAWINGS FOR SIZE & LOCATIONS
OF RETURN AIR LOUVERS IN CEILING OR WALLS.
38. G.C. TO PROCURE AN OFF-SITE STORAGE FACILITY FOR STORAGE OF ALL
DELIVERED MATERIALS, FIXTURES, ETC. FOR CONSTRUCTION OF STORE.
G.C. HAS 48 HOURS UPON RECEIPT OF ANY ITEM TO CHECK-IN SAID ITEM
& NOTE ANY DAMAGE OF ITEM. G.C. TO NOTIFY H&M OF ANY
DAMAGED ITEM(S) WITHIN THIS 48 HOUR PERIOD. IF NO NOTIFICATION
OCCURS WITHIN THE 48 HOUR PERIOD, G.C. ASSUMES RESPONSIBILITY
FOR CONDITION OF ITEM.
39. G.C. TO BEGIN CONSTRUCTION OF LEASED SPACE WITH INSTALLATION
OF FLOOR TILE AFTER DEMOLITION IS COMPLETED IN PHASE. ALL OTHER
NEW CONSTRUCTION SHALL OCCUR ON TOP OF FLOOR TILE. AFTER
FLOOR TILE HAS BEEN INSTALLED G.C. TO COVER TILE WITH PLYWOOD
(OR OTHER MATERIAL APPROVED BY H&M). AFTER FLOOR TILE HAS BEEN
INSTALLED G.G. SHALL NOT ALLOW THE USE OF LIFTS FOR ANY FURTHER
CONSTRUCTION OF THE LEASED SPACE.
40. ALL ANTI-THEFT WIRING DIMENSIONS & LOCATIONS BY TENANT
VENDOR.
41. WARDROBE TOP CONNECTORS TO BE INSTALLED BEHIND WARDROBE
HEADER CONNECTORS AND NOT TO BE EXPOSED TO SALES FLOOR.
42. ALL PLUMBING WALLS ARE TO BE 6" METAL STUD CONSTRUCTION.
43. DRYWALL AT DEMISING WALLS MUST CONTINUE TO METAL DECK (MUST
BE FIRE TAPED OR FIRE CAULKED TO DECK AS REQ'D BY CODE). ABOVE,
TO BE TAPED & PRIMED TO ABOVE FINISH CEILING ELEVATION OR
DESIGNATED SALES AREA HT IN OPEN CLG.
44. ALL WORK SHALL BE IN LOCAL COMPLIANCE W/ ADOPTED LOCAL
CODES, AIA A-210 CONDITIONS OF CONTRACT FOR CONSTRUCTION,
RECOGNIZED INDUSTRY STANDARDS IN THE AREA, ALL MANUFACTURERS
RECOMMENDATIONS, & ALL OTHER APPLICABLE CODES.
45. G.C. TO VERIFY WITH LANDLORD THE MAXIMUM DEPTH OF ANY
PENETRATIONS OR ANCHORS INTO THE SLAB BEFORE SLAB WORK
BEGINS
SYMBOL DESCRIPTION
TENANT LEASE LINE. PROJECT TEAM TO VERIFY IN FIELD.
STOREFRONT LEASE LINE AT POP-OUT. PROJECT TEAM TO VERIFY IN FIELD.
NEW STOREFRONT ENTRY & SAFETY GLASS GLAZING SYSTEM; REFER TO GENERAL NOTES/RESPONSIBILITY SCHEDULE & STOREFRONT SHTS. FOR MORE INFO.
NEDAP STOREFRONT SECURITY ANTENNA PANEL SYSTEM-SUPPLIED AND INSTALLED BY TENANT VENDOR. ANTENNAS NOT TO BE PLACED MORE THAN 5'-10" APART. G.C. TO COORDINATE LOCATION WITH
STORE FIXTURES. VENDOR TO SUBMIT SHOP DRAWINGS TO ARCHITECT FOR REVIEW AND APPROVAL.
G.C. TO CORE, PATCH CONCRETE SLAB AND PROVIDE CONDUIT FOR LOSS PREVENTION SECURITY PEDESTAL. COORDINATE WITH H&M VENDOR AND ELECTRICAL DRAWINGS PRIOR TO ROUGH-IN.
G.C. TO PROVIDE AND INSTALL ±7'-0" H. METAL SCREEN (MTL. MESH SCREEN OR EQUAL) BEHIND GYP. BD. AT ENTRY AREA. SEE A-601 FOR SPEC & MORE INFO. G.C. TO COORDINATE WITH H&M P.M. FOR
LOCATION AND FOR MORE INFORMATION.
STOREFRONT WINDOWS PODIUM AND TRENCH TO BE BUILT AND INSTALLED BY G.C. REFER TO FIXTURE AND STOREFRONT SHTS. FOR MORE INFORMATION. G.C. TO PROVIDE AND COORDINATE ELECTRICAL
REQUIREMENTS OF PLATFORM (TYP.) SEE ELEC. DRAWINGS. G.C. TO PROVIDE SHOP DRAWINGS FOR APPROVAL PRIOR TO FABRICATION.
VINYL APPLIED TO INSIDE OF GLASS, ACCORDING TO H&M "STORE INSTRUCTIONS".
WALLPAPER APPLIED TO BACK WALL & SIDES ACCORDING TO H&M "STORE INSTRUCTIONS". WALL & SIDES TO BE PAINTED WHITE PRIOR TO WALLPAPER APPLICATION.
PARTIAL HEIGHT FRAMELESS GLASS DISPLAY DOOR PROVIDED AND INSTALLED BY G.C. COORDINATE FINAL INSTALLATION WITH H&M PROJECT MANAGER. REFER TO SHT. A-800 FOR MORE INFORMATION..
1
2
3
4
5
6
7
8
9
10
FULL HEIGHT FLUSH WOODEN DISPLAY DOOR PROVIDED AND INSTALLED BY G.C. COORDINATE FINAL INSTALLATION WITH H&M PROJECT MANAGER. REFER TO SHT. A-800 FOR MORE INFORMATION..
DASHED LINE OF PAINTED GYP. BD. SOFFIT/HEADER ABOVE. SEE RCP SHT. FOR MORE INFO.
DASHED LINE OF LIGHT COVE ABOVE IN POSTER WINDOWS. SEE STOREFRONT SECTION & DETAILS FOR MORE INFO.
PROJECT TEAM TO FIELD VERIFY ANY NEW UTILITIES INSTALLED BY LANDLORD PRIOR TO START OF CONSTRUCTION AND NOTIFY OWNER IN WRITING OF FINDINGS.
ALL PLAN DIMENSIONS TO FINISH FACE OF PARTITION UNLESS NOTED OTHERWISE. FACE OF GYP. BD. WALLS, UNLESS OTHERWISE NOTED. ALL "EQ - EQ" DIMENSIONS ARE CONSIDERED TO BE MEASURED
FROM ADJACENT ARCHITECTURAL OR FIXTURE ELEMENT ON PLAN.
G.C. TO PROVIDE & INSTALL TYPE 'X' 5/8" THK. GYP BD. WHERE GYP. BD. IS NOT EXISTING ON TENANT SIDE OF DEMISING WALLS. FIRE TAPE, CAULK, & SEAL AS REQUIRED TO MAINTAIN RATING PER CODE.
RATING TO BE 1 HR. (UL#465) U.N.O.
G.C. TO PROVIDE & INSTALL TYPE 'X' 5/8" THK. GYP BD. AT STOREFRONT ON LANDLORD'S BASE AND WHERE GYP. BD. IS NOT EXISTING ON TENANT SIDE OF LANDLORD BULKHEAD. FIRE TAPE, CAULK, & SEAL AS
REQUIRED TO MAINTAIN RATING PER CODE.
PROVIDE NEW OR REPAIR EXISTING SPRAY-ON FIREPROOFING (WHERE APPLICABLE) TO MAINTAIN RATING AT ALL EXISTING OR NEW COLUMNS, BEAMS, AND FLOOR DECKS IF REQUIRED. TYPICAL FOR ENTIRE
H&M LEASED AREA.
HOLD COLUMN ENCLOSURE AS TIGHT AS POSSIBLE ON ALL SIDES. ENSURE COLUMN IS BUILT OUT LARGE ENOUGH TO ENCASE STANDARD DEPTH ELECTRICAL 1900 JUNCTION BOX, CONDUIT FOR RECESSED
DATA LOCATIONS, AND RECESSED FIRE EXTINGUISHER CABINET, IF REQ'D. SEE MEP DRAWINGS AND EGRESS PLAN FOR MORE INFORMATION.
EMERGENCY FIRE PULL. REFER TO M.E.P. DRAWINGS LOCATIONS & FOR MORE INFORMATION.
G.C. TO INSTALL CLEAR SIGNAGE INDICATING EXIT ROUTE (AS REQ'D. BY AHJ).
G.C. TO SUPPLY & INSTALL EMERGENCY EVACUATION MAPS. MAPS TO BE LAMINATED, LEGIBLE, AND EASILY VISIBLE. SEE EGRESS SHT. FOR MORE INFORMATION. CONFIRM FINAL LOCATION WITH H&M PM.
11
12
13
14
15
16
17
18
19
20
21
22
G.C. TO FIRE RATE ALL PENETRATIONS WITHIN TENANT SPACE (AS APPLICABLE) TO MEET CODE REQUIREMENTS.
G.C. TO PROVIDE RECEPTACLE/POWER FOR RECHARGEABLE FLASHLIGHT. REFER TO EGRESS SHT. FOR MOUNTING HEIGHT AND MORE INFORMATION.
G.C. TO PROVIDE AND INSTALL 2A10BC FIRE EXTINGUISHER PER NFPA 10 TO BE INSTALLED AT LOCATIONS SHOWN UNLESS DIRECTED OTHERWISE BY FIRE MARSHALL. G.C. TO INSTALL "FOAM" TYPE
EXTINGUISHERS IN ALL BACK OF HOUSE AREAS, "WATER" TYPE EXTINGUISHERS IN ALL SALES FLOOR AND FITTING ROOM AREAS, AND "CO2" TYPE EXTINGUISHERS IN ALL ELECTRICAL AND LAN. ROOM AREAS (IF
ALLOWABLE PER CODE). ALL FIRE EXTINGUISHERS SHALL BE CLEARLY MARKED WITH A SIGN PLACED AT MINIMUM 5'-10 7/8" A.F.F. AND MAXIMUM OF 6'-6 3/4" A.F.F. ENSURE THAT THERE IS ADEQUATE SPACE IN
WALL FOR RECESSED FIRE EXTINGUISHER CABINETS, IF REQ'D. REFER TO EGRESS SHT. FOR MORE INFORMATION.
LOCATION OF PVM (PUBLIC VIEW MONITOR) AT NEAREST COLUMN TO THE STOREFRONT ENTRY & OUTSIDE FITTING ROOM PORTAL. CCTV VENDOR IS RESPONSIBLE FOR ALL MONITOR LOCATIONS AND
EQUIPMENT COORDINATION WITH H&M PM. G.C. TO PROVIDE BLOCKING AS REQ'D. REFER TO VENDOR SHOP DRAWINGS FOR EXACT LOCATIONS. SEE DETAIL 1/A-322 & 'E' SHTS. FOR MORE INFO.
FIXTURE TO BE SECURED TO FLOOR. REFER TO H&M INTERIOR INSTRUCTIONS FOR APPROPRIATE SEASON & YEAR - FOR INSTALLATION REQUIREMENTS (SEE FIXTURE DETAILS FOR MORE INFO.)
WARDROBES, DIVIDERS AND OTHER FIXTURES W/INTEGRATED LIGHTING. J-BOXES TO BE COORDINATED WITH H&M INSTALLATION INSTRUCTIONS AND FIXTURE VENDOR. SEE FIXTURE PLAN SHT. & "E" SHTS. FOR
MORE INFO.
FIXTURE MIRROR LOCATIONS SHOWN ARE NOT NECESSARILY INDICATIVE OF FINAL LOCATIONS. G.C. SHALL COORDINATE WITH H&M REP. PRIOR TO INSTALLATION ANY AND ALL MIRRORS. COORDINATE
LOCATION OF FIRE ALARM HORNS, STROBES, PULL STATIONS, ETC.(IF REQ'D.) MIRROR LOCATIONS SHOULD BE TAKEN INTO CONSIDERATION BEFORE MOUNTING DEVICES. COORDINATE FINAL LOCATIONS
WITH H&M ON-SITE PROJECT MANAGER. THE DEVICES SHOULD NOT BE PLACED ON THE SAME FACE AS FIXTURE MIRROR (AT COLUMNS). G.C. TO COORDINATE AND ALERT OWNER/ARCHITECT WHERE THESE
CONFLICTS OCCUR PRIOR TO PLACEMENT OR INSTALLATION. IF PLACEMENT IS DIRECTED BY ANY, G.C. SHALL NOTIFY H&M OF ANY CONFLICT.
SPECIAL MIRROR ON COLUMN/PORTAL, PROVIDED AND INSTALLED BY G.C. G.C. SHALL COORDINATE WITH H&M REP. PRIOR TO INSTALLATION ANY AND ALL MIRRORS. COORDINATE LOCATION OF FIRE ALARM
HORNS, STROBES, PULL STATIONS, ETC. (IF REQ'D.). MIRROR LOCATIONS SHOULD BE TAKEN INTO CONSIDERATION BEFORE MOUNTING DEVICES. COORDINATE FINAL LOCATIONS WITH H&M ON-SITE PROJECT
MANAGER. THE DEVICES SHOULD NOT BE PLACED ON THE SAME FACE AS MIRROR (AT COLUMNS). G.C. TO COORDINATE AND ALERT OWNER/ARCHITECT WHERE THESE CONFLICTS OCCUR PRIOR TO
PLACEMENT OR INSTALLATION. IF PLACEMENT IS DIRECTED BY LOCAL GOVERNING JURISDICTION, G.C. SHALL NOTIFY H&M OF CONFLICT. REFER TO FINISH PLAN SHT. FOR LOCATIONS. REFER TO COLUMN
ENCLOSURE DETAILS SHTS. FOR MORE INFO.
EMPLOYEE ENTRANCE. PROVIDE CARD READER ACCESS TO STORE IF NOT ALREADY EXISTING. POWER TO DOOR FOR DELAYED ACTION EGRESS WITH OVERRIDE FROM FIRE ALARM SYSTEM. G.C. TO INSTALL
DOOR VIEWER, AND DOORBELL. VENDOR TO INSTALL INTERCOM AT EMPLOYEE ENTRANCE. REFER TO ELECTRICAL SHTS. FOR MORE INFORMATION.
OWNERS VENDOR TO INSTALL CCTV CAMERA ON OUTSIDE OF ADMIN. OFFICE DOOR WITH MONITOR INSTALLED ON INSIDE OF DOOR. REFER TO M.E.P. & SHOP DRAWINGS FOR MORE INFORMATION..
HANDICAPPED CASHWRAP PROVIDED BY H&M AND INSTALLED BY G.C. 3'-0" CLEAR REQUIRED BETWEEN FACE OF WARDROBE UNITS AND FACE OF CASHWRAPS FOR TOTAL LENGTH OF LAYOUT. 5'-0" CLEAR
WIDTH REQUIRED AREA IF ACCESS IS JUST FROM ONE SIDE. HEIGHT OF COUNTER TOP TO COMPLY WITH ICC/ANSI A117.1, SECTION 904 AND ADA AG. REFER TO FIXTURE SHTS. FOR MORE INFORMATION.
23
24
25
26
27
28
29
30
31
32
33
G.C. TO CUT, PATCH CONC. SLAB AND PROVIDE CONDUIT AND ELEC. SERVICE FOR CASHWRAP. G.C. TO COORDINATE W/ H&M VENDOR, ELEC. DWGS, SHOP DWGS, AND MANUFACTURER PRIOR TO
ROUGH-IN.
REFER TO ENLARGED FITTING ROOM PLANS ON SHT. A-730 SERIES FOR INFORMATION. REGARDING ADA COMPLIANCE, PARTITIONS AND ALL FITTING ROOM FIXTURES.
G.C. TO PROVIDE 1/2" THK. F.R.T. PLYWOOD BLOCKING AT ALL FITTING ROOM INTERIOR WALLS FOR ALL FITTING ROOM FIXTURING. NEW HOOKS THAT WILL BE MOUNTED AT 5'-0" O.C. IN ALL FITTING
ROOMS EXCEPT FOR THE ADA FITTING ROOM WHICH SHALL BE MOUNTED AT 48" A.F.F. REFER TO FIXTURE SHOP DRAWINGS AND H&M REP. FOR BLOCKING HEIGHTS.
ALL FITTING ROOM CURTAINS, FRAMES, WARDROBES AND HARDWARE FURNISHED BY TENANT, INSTALLED BY G.C. GENERAL CONTRACTOR TO COORDINATE WITH H&M'S FIXTURE CONTRACTOR FOR FINAL
DIMENSIONS.
PROVIDE ADA INTERNATIONAL SIGN FOR ACCESSIBILITY AT ALL ADA DRESSING COMPARTMENTS.
INTERNALLY ILLUMINATED STOREFRONT SIGN BY TENANT SIGN VENDOR. G.C. TO COORDINATE WITH STOREFRONT SHTS AND SIGN SHOP DRAWINGS FOR PROPER MOUNTING (PENDANT HUNG FROM
CEILING/SOFFIT ABOVE, FLUSH OR RECESSED 'PUSH-THRU') G.C. TO PROVIDE POWER AND BLOCKING PRIOR TO VENDOR INSTALLATION. REFER TO STOREFRONT SHTS. AND SIGNAGE SHOP DRAWINGS FOR
MORE INFORMATION.
STOREFRONT BLADE SIGN BY SIGN VENDOR LANDLORD'S. G.C. TO COORDINATE INSTALLATION WITH SIGN VENDOR. REFER TO STOREFRONT SHTS. FOR MORE INFORMATION. TYP., SEE CONSTRUCTION PLAN
FOR LOCATIONS.
FREE-STANDING LIGHTBOX AND/OR LOGO WALL FIXTURE PROVIDED BY H&M & INSTALLED BY G.C.; PROVIDE & INSTALL ALL ELECTRICAL REQUIREMENTS FOR LIGHTBOX & ASSOCIATED SIGNAGE. COORDINATE
HEIGHT OF J-BOX WITH LIGHTBOX SPECIFICATIONS. REFER TO ELECTRICAL DRAWINGS, H&M PROJECT MANAGER & H&M-PROVIDED "IPS DRAWINGS, CATALOGUES & CONSTRUCTION INFORMATION.".
LIGHT BOX FIXTURE SURFACE MOUNTED ON WALL PROVIDED BY H&M AND INSTALLED BY G.C. G.C. TO PROVIDE AND INSTALL IN-WALL F.R.T. PLYWOOD BLOCKING AS REQUIRED. G.C. SHALL SUPPLY AND
INSTALL ALL ELECTRICAL REQUIREMENTS FOR LIGHT BOX AND ASSOCIATED SIGNAGE. COORDINATE HEIGHT OF J-BOX WITH LIGHT BOX SPECIFICATIONS. REFER TO ELECTRICAL DRAWINGS, H&M PROJECT
MANAGER, AND H&M PROVIDED "IPS DRAWINGS, CATALOGUES, AND CONSTRUCTION INFORMATION." FOR MORE INFORMATION.
34
35
36
37
38
39
40
41
42
LIGHT BOX FIXTURE RECESSED MOUNTED ON WALL PROVIDED BY H&M AND INSTALLED BY G.C., CENTERED BEHIND CASHPOINTS ABOVE CASHWRAP ON STOREFRONT FACADE OR INTERIOR PARTITION (SEE
PLAN FOR EXACT LOCATIONS). SEE SIGNAGE DETAIL SHT. FOR MORE INFORMATION. G.C. TO PROVIDE AND INSTALL IN-WALL F.R.T. PLYWOOD BLOCKING AS REQUIRED. G.C. SHALL SUPPLY AND INSTALL ALL
ELECTRICAL REQUIREMENTS FOR LIGHT BOX AND ASSOCIATED SIGNAGE. COORDINATE HEIGHT OF J-BOX WITH LIGHT BOX SPECIFICATIONS. REFER TO ELECTRICAL DRAWINGS, H&M PROJECT MANAGER, AND
H&M PROVIDED "IPS DRAWINGS, CATALOGUES, AND CONSTRUCTION INFORMATION." FOR MORE INFORMATION.
LED STORE GUIDE (SURFACE MTD. ON WALL OR FREESTANDING) PROVIDED BY H&M AND INSTALLED BY G.C. G.C. TO PROVIDE AND INSTALL IN-WALL F.R.T. PLYWOOD BLOCKING AS REQUIRED. G.C. SHALL
SUPPLY AND INSTALL ALL ELECTRICAL REQUIREMENTS FOR STORE GUIDE. COORDINATE HEIGHT OF J-BOX WITH STORE GUIDE SPECIFICATIONS. REFER TO SHT. A-551, 'E' DRAWINGS, H&M PROJECT MANAGER,
AND H&M PROVIDED "IPS DRAWINGS, CATALOGUES, AND CONSTRUCTION INFO." FOR MORE INFO.
REFER TO ELECTRICAL DRAWINGS FOR ROOM REQUIREMENTS.
G.C. TO INSTALL PVC PIPE DRAWING TUBE IN ELECTRICAL ROOM. REFER TO DETAIL ON SHT. 8/A-750 FOR MORE INFORMATION., AND H&M PROJECT MANAGER FOR EXACT LOCATION.
G.C. TO ADD ONE (1) LAYER OF CONT. 3/4" F.R.T. PLYWOOD ON ALL WALLS OF LAN. ROOM AND ELECTRICAL ROOM FOR ALL ELECTRICAL/DATA/ETC. EQUIPMENT. REFER TO PARTITION TYPES ON SHEET A-700
FOR MORE INFORMATION. G.C. TO INSTALL FIRE RATED PLYWOOD FROM FINISHED FLOOR TO 8'-0" A.F.F.. G.C. TO INSTALL PLYWOOD "STAMP-SIDE OUT" SO FIRE RATING STAMP IS VISIBLE AFTER
INSTALLATION. (DO NOT PAINT)
REFER TO FIXTURE PLAN & BOH SHTS. FOR STOCK ROOM LAYOUT & FIXTURES.
APPROXIMATE LOCATION OF IRON OUTLET. SEE ELECTRICAL SHTS. FOR MORE INFO.
G.C. TO PROVIDE COVER PLATES FOR ALL EXISTING FLOOR DRAINS, AS REQ'D
G.C. TO PROVIDE SERVICE ENTRANCE DOOR SIGN.
DELIVERY DOOR WITH DOORBELL.
PRIVACY FROSTED WINDOW FILM (OR LIFESTYLE GRAPHIC) PROVIDED BY H&M. INSTALLED BY G.C.
NEW ENTRY VESTIBULE AND DOORS BY H&M - REFER TO GENERAL NOTES/RESPONSIBILITY SCHEDULE & STOREFRONT SHTS. FOR MORE INFORMATION..
APPROXIMATE LOCATION OF EXISTING EXPANSIONS JOINT IN TENANT SPACE, G.C. TO V.I.F.
STAIR + PLATFORM ACCESS TO DISPLAY WINDOW.
43
44
45
46
47
48
49
50
51
52
53
54
55
56
CONSTRUCTION GENERAL NOTESCONSTRUCTION KEY NOTES
GENERAL AND KEY NOTES
MH
A-212
CONSTRUCTION PLAN
NOT USED
NOT USED
NOT USED
NOT USED
NOT USED
NOT USED
NOT USED
EQ.EQ.
EQ.EQ.
EQ.EQ. EQ.EQ.
EQ.EQ.
EQ.EQ.
EQ.EQ.
EQ.EQ.
EQ.EQ.
EQ.EQ.
EQ.EQ.
EQ.EQ.
CL CL CL
CLCLCL
CL
CL CL CL
CLCL
30"x48"
PREPARE OUTLET
FOR IRON
42"
ROUND
FITTING ROOM
S2S3 S1
LADIES
S2S3 S1
C
H4 H4
H3
H3 H3
H3
G
H4
H4
G
G
G
G
G
G G G G G
G
G
G
G
G
G G
G
G
H3
H3
H3
H3 H3 H3 H3
H3
(LADIES)
SALES AREA
ACT-1
001
(LAD. DIV)
SALES AREA
ACT-1
001
(KIDS)
SALES AREA
ACT-1
001
ROOM #1
STOCK
PT-1
017
LOUNGE
ACT-1
014
WINDOW #4
POSTER
PT-1
008
WINDOW #1
POSTER
PT-1
002
WINDOW
OPEN
PT-1
003
WINDOW #2
POSTER
PT-1
004
WINDOW
DISPLAY
PT-1
005
ENTRY
PT-1
006
WINDOW #3
POSTER
PT-1
007
ROOM
ADMIN
PT-1
009
MTG. RM.
SECURITY
ACT-1
010
HALLWAY
ACT-1
012
CLOSET
JANITOR'S
PT-1
011
TOILET RM.
WOMEN'S H/C
PT-1
013
TOILET RM.
MEN'S H/C
PT-1
015
ROOM
LAN
N/A
016
ROOM
ELECTRICAL
N/A
018
AREA #1
FITTING RM.
PT-1
019
ROOM #2
STOCK
PT-1
020
AREA #2
FITTIN RM.
PT-1
021
ROOM #3
STOCK
PT-1
022
WINDOW #5
POSTER
PT-1
023
(MENS)
SALES AREA
ACT-1
001
NIGHTBOX
REMOTE
PT-1
024
(PORTAL)
PT-3
(PORTAL)
PT-3
(PORTAL)
PT-3
(PORTAL)
PT-3
(PORTAL)
PT-3
G G G
GGG
EXTERIOR
H3
H3 H3
H3
H3
H3
GGG
G G
G
G
G
G
A
B
C
D
E
C.3
12345678910
EXTERIOR
EXTERIOR
EXTERIOR
EXTERIOR
MALL SERVICE
CORRIDOR
MALL SERVICE
CORRIDOR
(LIGHT COVE)
PT-1
(LIGHT COVE)
PT-1
(LIGHT COVE)
PT-1
(LIGHT COVE)
PT-1
(LIGHT COVE)
PT-1
(LIGHT COVE)
PT-1
(LIGHT COVE)
PT-1
(LIGHT COVE)
PT-1
NOTE:
1. SEE LIGHTING SCHEDULE FOR LIGHTING LEGEND.
2. G.C. TO PROVIDE BLOCKING ABOVE CEILING OR ON WALL, AS
REQUIRED, FOR ALL CEILING / WALL MOUNTED SPECIALTY LIGHTING
FIXTURES & SIGNS, U.O.N.
SYM. DESCRIPTION
STANDARD WHITE CEILINGS: ARMSTRONG DUNE 2'x2'x5/8"
#1772
GREY CEILINGS: ARMSTRONG DUNE 2'x2'x5/8"
#1772 MR87392
GYP. BD. CEILING; REFER TO FINISH PLAN & CEILING DETAILS
HATCHED AREA DENOTES FRAMED SOFFIT / CURTAIN WALL
CONSTRUCTION; REFER TO CEILING DETAILS
CEILING TAG
CEILING SECTION/DETAIL TAG - SEE CEILING DETAILS SHEET
REFLECTED CEILING PLAN TAG NOTEX
CLG. HT.
FINISH
NO. DESCRIPTION
TENANT LEASE LINE. PROJECT TEAM TO VERIFY IN FIELD.
STOREFRONT LEASE LINE AT POP-OUT. PROJECT TEAM TO VERIFY
IN FIELD.
HATCHED LIGHT INDICATES EMERGENCY FUNCTION. NL TO
INDICATE NIGHT-LIGHT FUNCTION. REFER TO ELECTRICAL SHTS.
FOR MORE INFORMATION.
CONCEALED EMERGENCY LIGHT HOUSING TO BE PRE-FINISHED
WITH PAINT TO MATCH ADJACENT CEILING COLOR. TYP.
INTERNALLY ILLUMINATED STOREFRONT SIGN BY SIGN VENDOR.
G.C. TO COORDINATE WITH STOREFRONT SHTS AND SIGN SHOP
DRAWINGS FOR PROPER MOUNTING IF PENDANT HUNG FROM
CEILING/SOFFIT ABOVE, FLUSH OR RECESSED 'PUSH-THRU'. G.C.
TO PROVIDE POWER AND BLOCKING PRIOR TO VENDOR
INSTALLATION. REFER TO STOREFRONT SHTS. AND SIGNAGE
SHOP DRAWINGS FOR MORE INFORMATION.
INTERNALLY ILLUMINATED STOREFRONT BLADE SIGN BY SIGN
VENDOR. G.C. TO PROVIDE POWER AND BLOCKING PRIOR TO
VENDOR INSTALLATION. REFER TO STOREFRONT SHTS. AND
SIGNAGE SHOP DRAWINGS FOR MORE INFORMATION. TYP., SEE
CONSTRUCTION PLAN FOR LOCATIONS.
1
2
3
4
5
6
ACT CEILING EXPANSION JOINT. REFER TO SHT A-720 FOR MORE
INFORMATION.
LIGHT BOX FIXTURE SURFACED MOUNTED ON WALL PROVIDED
BY H&M AND INSTALLED BY G.C., CENTERED BEHIND CASHPOINTS
ABOVE CASHWRAP ON STOREFRONT FACADE OR INTERIOR
PARTITION (SEE PLAN FOR EXACT LOCATIONS). SEE SIGNAGE
DETAIL SHT. FOR MORE INFORMATION. G.C. TO PROVIDE AND
INSTALL IN-WALL F.R.T. PLYWOOD BLOCKING AS REQUIRED.
G.C. SHALL SUPPLY AND INSTALL ALL ELECTRICAL REQUIREMENTS
FOR LIGHT BOX AND ASSOCIATED SIGNAGE. COORDINATE
HEIGHT OF J-BOX WITH LIGHT BOX SPECIFICATIONS. REFER TO
ELECTRICAL DRAWINGS, H&M PROJECT MANAGER, AND H&M
PROVIDED "IPS DRAWINGS, CATALOGUES, AND CONSTRUCTION
INFORMATION." FOR MORE INFORMATION.
ILLUMINATED NAVIGATION SIGN BY H&M, (CENTERED ABOVE
PORTAL OPENING OR CEILING MOUNTED - WHERE APPLICABLE).
INSTALLED BY E.C. G.C. TO PROVIDE POWER AND BLOCKING.
REFER TO DETAIL ON A-322 & SIGNAGE SHOP DRAWINGS FOR
MORE INFORMATION.
LED STORE GUIDE SURFACE MTD. ON WALL PROVIDED BY H&M
AND INSTALLED BY G.C. G.C. TO PROVIDE AND INSTALL IN-WALL
F.R.T. PLYWOOD BLOCKING AS REQUIRED. G.C. SHALL SUPPLY
AND INSTALL ALL ELECTRICAL REQUIREMENTS FOR STORE GUIDE.
COORDINATE HEIGHT OF J-BOX WITH STORE GUIDE
SPECIFICATIONS. REFER TO SHT. A-551, 'E' DRAWINGS, H&M
PROJECT MANAGER, AND H&M PROVIDED "IPS DRAWINGS,
CATALOGUES, AND CONSTRUCTION INFO." FOR MORE INFO.
7
8
9
10
LIGHT COVE, AT POSTER WINDOWS ONLY. REFER TO RCP &
STOREFRONT SECTION SHTS. FOR MORE INFO.
LINEAR LED LIGHTS AT POSTER WINDOWS ONLY. REFER TO
STOREFRONT SECTIONS SHTS. FOR PLACEMENT
REFER TO STOREFRONT SECTION SHTS. FOR POSITION OF TRACK
LIGHTS / LED LINEAR LIGHTING IN STOREFRONT OPEN, DISPLAY
AND POSTER WINDOWS.
CLIPS FOR TRACK LIGHTING EVERY 48" SCREWED DIRECTLY TO 'T'
BAR. G.C. TO TIGHTEN CLIPS PRIOR TO STORE OPENING
G.C. TO COORDINATE SIZE AND LOCATION WHERE ACCESS
PANELS ARE REQUIRED. NOTIFY ARCHITECT, AND CONFIRM FINAL
QUANTITY AND LOCATIONS OF ALL ACCESS PANELS SHOWN ON
SITE. MANUFACTURER: ACUDOR OR EQUAL.
CONTACT: BARBARA CURRAW
ACUDOR PRODUCTS INC.
80 LITTLE FALLS RD. FAIRFIELD, NJ 07004
973-575-5120
BCURRAW@ACUDOR.COM
HEIGHT OF FITTING ROOM ENTRY PORTALS TO ALIGN WITH TOP
OF FITTING ROOM SPECIAL PANELS. G.C. MUST OBTAIN AN
ACTUAL FITTING ROOM SPECIAL PANEL TO THE JOB SITE IN
ORDER TO INSTALL HEADER ACCURATELY AT FITTING ROOM
PORTAL FROM SALES AREA.
G.C. TO PROVIDE BLOCKING IN CEILING FOR FULL HEIGHT
FRAMEWORK FIXTURES AND CEILING MOUNTED LIT NAVIGATION
SIGNS. SEE DETAILS ON A-720 FOR MORE INFORMATION.
11
12
13
14
15
16
17
1. GC TO COORDINATE ALL NECESSARY WALL OR
CEILING ACCESS PANELS WITH LAYOUT (USE
INTEXFORMS ACCESS PANELS, RADIAL
CORNERS, 'GRFG'). PROVIDE ACCESS PANEL
LAYOUT TO ARCHITECT AND ENGINEER FOR
APPROVAL. REFER TO MEP SHEETS FOR MORE
INFORMATION. CONFIRM LOCATIONS WITH
LANDLORD'S REP. GC TO INCLUDE IN BID QTY.
(6) MIN. 24"X24" CONCEALED TYPE IN GYP. BD.
CEILINGS.
2. GC TO CLEAN ALL INSTALLED LIGHTING
FIXTURES PRIOR TO TURN OVER AS REQUIRED.
3. REFER TO MEP SHEETS FOR FIRE PROTECTION
DIRECTION. ALL FIRE PROTECTION SPRINKLER
HEADS ARE TO BE PLACED AS TO NOT
INTERFERE WITH LIGHTING, HVAC AND STORE
FIXTURING COMPONENTS.
4. CEILING GRID IN BACK OF HOUSE SUPPORT
OFFICES ARE TO BE HUNG WITH #12 HANGER
WIRES (48"O.C.) WITH ADDITIONAL WIRES AT
ALL FOUR CORNERS OF ALL LIGHT FIXTURES,
DIFFUSERS, ETC.
5. ALL SUSPENDED COMPONENTS ARE TO BE
SUSPENDED FROM TOP CHORD OF EXISTING
JOISTS. DO NOT ATTACH SUSPENSION
ATTACHMENTS FROM METAL ROOF DECKING
(IN CONCRETE DECKING USE APPROVED
CONCRETE FASTENERS).
6. SUSPENDED ACOUSTICAL CEILING SYSTEM IS
TO BE IN COMPLIANCE WITH THE APPLICABLE
CODE AND ASTM C 635 AND ASTM C 636.
7. ELECTRICAL CONTRACTOR TO MAKE ALL FINAL
CONNECTIONS TO MILLWORK / FIXTURES /
CASHWRAPS IN FIELD.
8. COORDINATE LIGHTING FIXTURE LOCATIONS
AND DIFFUSER LOCATIONS WITH OTHER
CEILING COMPONENTS WITH LIGHTING BEING
THE DECIDING COMPONENT.
9. SPEAKERS PROVIDED AND INSTALLED BY
OTHERS. GENERAL CONTRACTOR TO PROVIDE
AND INSTALL: CONDUITS, J-BOXES FOR DJ
JACK(S), VOLUME CONTROLS, PULL ALL WIRES
AND SPEAKER CANS AS SHOWN ON
DRAWINGS. OWNER'S VENDOR TO INSTALL
FINAL HOOK UP OF SPEAKERS AND
EQUIPMENT. SPEAKER BACK BOXES SUPPLIED
BY OWNER'S VENDOR AND INSTALLED BY GC.
10. CONTRACTOR TO PROVIDE COORDINATION
DRAWING FOR ALL TRADES INCLUDING
SPRINKLER, MECHANICAL, ELECTRICAL, FIRE
ALARM, SECURITY, ACCESS PANEL & ETC. IN
CEILING FOR ARCHITECT'S APPROVAL PRIOR
TO CONSTRUCTION. UNCOORDINATED
CONDITIONS THAT ARE CONTRARY TO THE
DESIGN INTENT ARE THE SOLE RESPONSIBILITY
OF THE CONTRACTOR TO RESOLVE.
11. IN THE CASE OF DISCREPANCY BETWEEN THE
ARCHITECT'S AND/OR ENGINEER'S DRAWINGS,
THE MORE STRINGENT, HIGHER QUANTITY, OR
HIGHER QUALITY SHALL PREVAIL. ARCHITECT IS
TO BE ADVISED OF ALL DISCREPANCIES PRIOR
TO START OF CONSTRUCTION.
12. ALL DIMENSIONS TO BE COORDINATED IN THE
FIELD WITH H&M AND ARE SUBJECT TO
EXISTING CONDITIONS DIMENSIONS MARKED
AS EQUAL (EQ.) APPLY ONLY WITHIN A GIVEN
STRING OF DIMENSIONS UNLESS OTHERWISE
MARKED.
13. ALL SPEAKERS MUST BE FLUSH MOUNT AND
FINISHED TO MATCH ADJACENT CEILING
FINISH. GC TO COORDINATE WITH SPEAKER
CONTRACTOR TO CENTER SPEAKERS BETWEEN
LIGHT FIXTURES (ALONG STRAIGHT OR
DIAGONAL LINE) AS SHOWN ON PLAN
WHEREVER POSSIBLE.
14. ALL CONDUITS TO BE CONCEALED UNLESS
OTHERWISE NOTED. LAYOUT FOR ANY
EXPOSED ELECTRICAL CONDUIT TO BE
APPROVED BY H&M IN FIELD PRIOR TO
INSTALLATION.
15. ALL SPRINKLER HEADS TO BE FLUSH MOUNT
WITH COVER PLATE AT ALL FINISHED CEILINGS,
CENTERED ON LIGHT FIXTURES LAYOUT OR
CEILING TILES AS APPLICABLE.
16. REFER TO FINISH FLOOR PLANS FOR FINISH
NOTES. GC TO VERIFY ALL CEILING FINISHES
WITH H&M PRIOR TO CONSTRUCTION. ALL
CEILING ELEMENTS AND DEVICES (LIGHT
FIXTURE HOUSINGS AND TRIMS, SPEAKERS,
SPRINKLER CAPS, GRILLES, DIFFUSERS, ETC.)
SHALL BE PRE-FINISHED OR BE PAINTED OR
COLORED THE SAME COLOR AS THE ADJACENT
CEILING PAINT. ALL PAINTING SHALL BE
COMPLETED OFFSITE. GC TO COORDINATE
WITH VENDORS AND SUBCONTRACTORS FOR
CORRECT FINISHES AND LONG LEAD ITEMS.
17. ALL VERTICAL ELEMENTS OF SOFFITS TO BE
PAINTED TO MATCH ADJACENT COPLANAR
WALL PAINT.
18. SPRAY ALL VISIBLE AREA ABOVE GYP. BD. &
ACT CEILING BLACK.
19. GC TO PLUG ALL LIGHT LEAKS IN DISPLAY
WALLS/FIXTURES.
20. ALL TRIMLESS LIGHTS TO RECEIVE TEARAWAY
BEAD. TRIMLESS LIGHTS TO HAVE SMOOTH,
CLEAN EDGES AND ARE TO BE INSTALLED FLUSH
WITH ADJACENT CEILING.
21. LIGHT GRID TAKES PRECEDENCE WHEN
INSTALLING ALL CEILING ELEMENTS. IF ANY
INTERFERENCES OCCUR BETWEEN LIGHT GRID,
CEILING DIFFUSERS, SPEAKERS, ETC. THE LIGHT
GRID SHALL NOT MOVE. GC SHALL NOTIFY
ARCHITECT OF DISCREPANCY. ALL CEILING
ELEMENTS TO ALIGN WITH GRID.
22. REFER TO LIGHTING FIXTURE SCHEDULE AND
NOTES ON ELECTRICAL DRAWINGS FOR
FIXTURE SUPPLY/INSTALLATION
RESPONSIBILITIES AND EMERGENCY LIGHTING
LOCATIONS.
23. ALL EXPOSED STRUCTURAL STEEL TO BE
FIRE-PROOFED PER LOCAL CODES. GC TO
REPAIR ALL EXISTING FIREPROOFING.
24. GC TO ASSUME CEILING TILES TO BE CENTERED
IN ROOM IN BOTH DIRECTIONS, U.N.O.
25. USG GYP. BD. DROPPED CEILING HAS 16"
GRID. COORDINATE WITH RECESSED LIGHT
FIXTURE LOCATIONS PER INDIVIDUAL AREAS.
26. GC TO PROVIDE BLOCKING ABOVE CEILING
OR ON THE WALL, AS REQUIRED, FOR ALL
CEILING MOUNTED SPECIALTY LIGHTING
FIXTURES AND SIGNS, UNLESS OTHERWISE
NOTED.
27. ELECTRICIAN TO MARK ALL SWITCH, OUTLET,
SPEAKER, CAMERA AND SECURITY LOCATIONS
IN FIELD AND WALK THROUGH WITH H&M
BEFORE INSTALLATION - ALL LOCATIONS ARE
SUBJECT TO H&M APPROVAL.
28. SPEAKER VENDOR TO PROVIDE WIRE AND E.C.
TO PULL AND INSTALL WIRE. WIRE IS TO BE
PLENUM RATED AND DOES NOT NEED TO BE
INSTALLED IN CONDUIT UNLESS LOCAL
JURISDICTION REQUIRES. IF REQUIRED, E.C. IS
TO INSTALL CONDUIT.
29. TRACK AND CONNECTORS MUST BE
PRE-FINISHED WITH COLOR TO MATCH
CEILING.
30. U.S.G. GYP. BD. DROPPED CEILING HAS 16"
GRID. COORDINATE GRID WITH RECESSED
LIGHT FIXTURE LOCATIONS PER INDIVIDUAL
AREAS.
31. PORTALS TO BE 9'-6" A.F.F. AND PAINTED PT-1.
FITTING ROOM PORTALS (PAINTED PT-1) TO BE
COORDINATED WITH FITTING ROOM "WP-1"
PANEL HEIGHTS . FOR CEILING HEIGHTS LOWER
THAN 8'-3" PORTALS SHALL BE IN LINE WITH
TOP OF WARDROBE. USE THESE GENERAL
GUIDELINES UNLESS OTHERWISE NOTED.
32. GC TO PROVIDE TEAR AWAY BEAD AT ALL
TRIMLESS FIXTURES.
ACT-1
ACT-2
GENERAL CEILING NOTES
CEILING SYMBOL LEGEND
REFLECTED CEILING KEY NOTES
EQ.EQ.
EQ.EQ.
EQ.EQ. EQ.EQ.
EQ.EQ.
EQ.EQ.
EQ.EQ.
EQ.EQ.
EQ.EQ.
EQ.EQ.
EQ.EQ.
EQ.EQ.
CL CL CL
CLCLCL
CL
CL CL CL
CLCL
17
7'-0" 7'-0"
CL CL CL
6'-0"EQ.EQ.
CL
CL
3'-77
8"
8'-0"3'-77
8"
EQ. 6'-0" 6'-0" EQ.
5'-11" 6'-0" 6'-0" 6'-0" 6'-0" 5'-117
8"
5'-41
2"5'-93
8"
EQ. EQ.
1'-93
4"6'-0"6'-0"6'-0"6'-0"
EQ. EQ.
EQ.EQ.
6'-0"6'-0"6'-0"EQ.EQ.
EQ.EQ.
EQ.EQ.
EQ. EQ.
EQ.EQ.
EQ.EQ.
2'-11" 4'-0"
TYP.
2'-53
4"4'-65
8"
1'-77
8"2'-0"
6'-93
8"6'-11"
5'-73
4"6'-0"6'-0"
EQ.EQ.
5'-25
8"
EQ.EQ.
2'-15
8" 4'-0"
TYP.
2'-11
4"
1'-111
8"2'-0"
1 1 1
1
1
1
1
1
1 1
1
1
1
TYP.
4
3
14
TYP.
4
3
14
TYP.
4
3
14
TYP.
4
3
14
3
3
3
3
15
4
3
15
4
3 4 15
17 17
17
17
17
3
9
9
9
9
9
9
10
5
5
6
6
16
16
8
8
8
11 11 11 11
11
12
11
12
12 12 12 12 12 1213141314
TYP.
6
TYP.
6
TYP.
6
TYP.
6
TYP.
1
TYP.
1
TYP.
1
TYP.
1
TYP.
9
TYP.
9
TYP.
1
TYP.
1
TYP.
2
TYP.
2
EQ.EQ.
EQ. EQ.
EQ. EQ.
EQ.EQ.
EQ.EQ.
FULL
TILE
FULL
TILE
FULL
TILE
FULL
TILE
EQ.EQ.
EQ.EQ.EQ.EQ.
EQ. EQ.
3'-13
8"
TYP.
3'-81
8"
TYP.
3'-53
8"
TYP.
3'-53
8"
TYP.
1'-07
8"
43
4"
1'-27
8"
51
8"
31
4"
15 15 15 15 15 15 15 1515
15
15
2
EQ. EQ.
5
EQ. 19'-75
8" EQ.
EQ.3'-6"EQ.
REVISION:
SHEET TITLE:
SPACE NO.:
ARCH PROJECT NO.:
SCALE:
DRAWN BY:
REV. NO:
SHEET NO:
PRODUCT SEASON:
2018
US667-BLUE
BRANSONLANDING
BUILDING1000
SPACENOS.1003-1013
100BRANSONLANDINGBLVD
BRANSON,MOZIP65616
AS NOTED
2018
2187-17
ISSUE DATE:
1003-1013
D.O.B. NO:
12.18.17 CLIENT/LANDLORD REVIEW
REFLECTED CEILING PLAN 1
SCALE: 1/8" = 1'-0"
REFLECTED CEILING PLAN (REMOTE NIGHTBOX) 2
SCALE: 1/8" = 1'-0"
NORTH
RECESSED LIGHTS DIMS. - (TYP.) 3
SCALE: N.T.S. (FOR REFERENCE AND GENERAL INFORMATION ONLY)
MH
A-310
REFLECTED CEILING
PLANS
NOT USED
NOT USED
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY
Work samples TALA JAZZY

More Related Content

What's hot

Item # 7 - 324 Cloverleaf
Item # 7 - 324 CloverleafItem # 7 - 324 Cloverleaf
Item # 7 - 324 Cloverleafahcitycouncil
 
KASSIN TRELLIS
KASSIN TRELLISKASSIN TRELLIS
KASSIN TRELLISSean Roper
 
Oretsky Residence - Full Permit Set
Oretsky Residence - Full Permit SetOretsky Residence - Full Permit Set
Oretsky Residence - Full Permit SetSadaf Mohammadi
 
AIA 2015-2016 PLAN SET
AIA 2015-2016 PLAN SETAIA 2015-2016 PLAN SET
AIA 2015-2016 PLAN SETAlexis Torres
 
2012.10.26_Blanco Residence - full permit set
2012.10.26_Blanco Residence - full permit set2012.10.26_Blanco Residence - full permit set
2012.10.26_Blanco Residence - full permit setSadaf Mohammadi
 
Commercial project
Commercial projectCommercial project
Commercial projectAyat Aljafar
 
Farmers Agoura Hills CEO Office
Farmers Agoura Hills CEO OfficeFarmers Agoura Hills CEO Office
Farmers Agoura Hills CEO OfficeRichard Clark
 
Colonial style house design
Colonial style house design Colonial style house design
Colonial style house design Miguel Zamarripa
 
Portfolio Nidhi Raval
Portfolio Nidhi RavalPortfolio Nidhi Raval
Portfolio Nidhi RavalNidhi Raval
 
Ornamental aluminum fence systems.
Ornamental aluminum fence systems.Ornamental aluminum fence systems.
Ornamental aluminum fence systems.aruvilinternational
 
CM-Kitchen Design Project
CM-Kitchen Design ProjectCM-Kitchen Design Project
CM-Kitchen Design ProjectChoungmi Lee
 
Horsey Bonus Room Reno Opt 3_Bed 022516
Horsey Bonus Room Reno Opt 3_Bed 022516Horsey Bonus Room Reno Opt 3_Bed 022516
Horsey Bonus Room Reno Opt 3_Bed 022516Shannon Horsey
 
YU MIN LIU _ 2017 PORTFOLIO_FULL 11_17
YU MIN LIU _ 2017 PORTFOLIO_FULL 11_17YU MIN LIU _ 2017 PORTFOLIO_FULL 11_17
YU MIN LIU _ 2017 PORTFOLIO_FULL 11_17YUMI CHEN
 
Vipul Aarohan New Residential Project in Sector 53 Golf Course Road Gurgaon
Vipul Aarohan New Residential Project in Sector 53  Golf Course Road GurgaonVipul Aarohan New Residential Project in Sector 53  Golf Course Road Gurgaon
Vipul Aarohan New Residential Project in Sector 53 Golf Course Road GurgaonHometrust Realty Pvt Ltd
 

What's hot (20)

Drafting and Design
Drafting and DesignDrafting and Design
Drafting and Design
 
Item # 7 - 324 Cloverleaf
Item # 7 - 324 CloverleafItem # 7 - 324 Cloverleaf
Item # 7 - 324 Cloverleaf
 
KASSIN TRELLIS
KASSIN TRELLISKASSIN TRELLIS
KASSIN TRELLIS
 
20150811-Allied Telecom
20150811-Allied Telecom20150811-Allied Telecom
20150811-Allied Telecom
 
Oretsky Residence - Full Permit Set
Oretsky Residence - Full Permit SetOretsky Residence - Full Permit Set
Oretsky Residence - Full Permit Set
 
AIA 2015-2016 PLAN SET
AIA 2015-2016 PLAN SETAIA 2015-2016 PLAN SET
AIA 2015-2016 PLAN SET
 
2012.10.26_Blanco Residence - full permit set
2012.10.26_Blanco Residence - full permit set2012.10.26_Blanco Residence - full permit set
2012.10.26_Blanco Residence - full permit set
 
Commercial project
Commercial projectCommercial project
Commercial project
 
20150330_R4D_Permit Set
20150330_R4D_Permit Set20150330_R4D_Permit Set
20150330_R4D_Permit Set
 
Farmers Agoura Hills CEO Office
Farmers Agoura Hills CEO OfficeFarmers Agoura Hills CEO Office
Farmers Agoura Hills CEO Office
 
Colonial style house design
Colonial style house design Colonial style house design
Colonial style house design
 
Portfolio Nidhi Raval
Portfolio Nidhi RavalPortfolio Nidhi Raval
Portfolio Nidhi Raval
 
Ornamental aluminum fence systems.
Ornamental aluminum fence systems.Ornamental aluminum fence systems.
Ornamental aluminum fence systems.
 
Am ltwn hseleft (1)
Am ltwn hseleft (1)Am ltwn hseleft (1)
Am ltwn hseleft (1)
 
22
2222
22
 
CM-Kitchen Design Project
CM-Kitchen Design ProjectCM-Kitchen Design Project
CM-Kitchen Design Project
 
Excess inventory
Excess inventoryExcess inventory
Excess inventory
 
Horsey Bonus Room Reno Opt 3_Bed 022516
Horsey Bonus Room Reno Opt 3_Bed 022516Horsey Bonus Room Reno Opt 3_Bed 022516
Horsey Bonus Room Reno Opt 3_Bed 022516
 
YU MIN LIU _ 2017 PORTFOLIO_FULL 11_17
YU MIN LIU _ 2017 PORTFOLIO_FULL 11_17YU MIN LIU _ 2017 PORTFOLIO_FULL 11_17
YU MIN LIU _ 2017 PORTFOLIO_FULL 11_17
 
Vipul Aarohan New Residential Project in Sector 53 Golf Course Road Gurgaon
Vipul Aarohan New Residential Project in Sector 53  Golf Course Road GurgaonVipul Aarohan New Residential Project in Sector 53  Golf Course Road Gurgaon
Vipul Aarohan New Residential Project in Sector 53 Golf Course Road Gurgaon
 

Similar to Work samples TALA JAZZY

bdorsey_MassTimber_FinalCDs
bdorsey_MassTimber_FinalCDsbdorsey_MassTimber_FinalCDs
bdorsey_MassTimber_FinalCDsBryan Dorsey
 
2009 1209 Asce Powerpoint Presentation
2009 1209 Asce Powerpoint Presentation2009 1209 Asce Powerpoint Presentation
2009 1209 Asce Powerpoint PresentationSiobone
 
senior year portfolio small
senior year portfolio smallsenior year portfolio small
senior year portfolio smallEdward Sweeney
 
5.1 Mixed use building
5.1 Mixed use building5.1 Mixed use building
5.1 Mixed use buildingshabbirtg
 
portfolio june 24 finished portfolio
portfolio june 24 finished portfolioportfolio june 24 finished portfolio
portfolio june 24 finished portfolioAndrew Johnson
 
R levine portfolio
R levine portfolioR levine portfolio
R levine portfoliorl321
 
Katie Johnson Portfolio
Katie Johnson PortfolioKatie Johnson Portfolio
Katie Johnson PortfolioKatie Johnson
 
Cordy Commercial_Brochure_190x257_v20
Cordy Commercial_Brochure_190x257_v20Cordy Commercial_Brochure_190x257_v20
Cordy Commercial_Brochure_190x257_v20Joseph Edwards
 
Interior Design student work (Dezyne E' cole College)
Interior Design student work (Dezyne E' cole College)Interior Design student work (Dezyne E' cole College)
Interior Design student work (Dezyne E' cole College)dezyneecole
 
5 Churchill Place
5 Churchill Place5 Churchill Place
5 Churchill PlaceCVydra
 
AIA COTE 2030: Skins 20121214
AIA COTE 2030: Skins 20121214AIA COTE 2030: Skins 20121214
AIA COTE 2030: Skins 20121214kaplanthompson
 

Similar to Work samples TALA JAZZY (19)

Harbor house
Harbor houseHarbor house
Harbor house
 
bdorsey_MassTimber_FinalCDs
bdorsey_MassTimber_FinalCDsbdorsey_MassTimber_FinalCDs
bdorsey_MassTimber_FinalCDs
 
2009 1209 Asce Powerpoint Presentation
2009 1209 Asce Powerpoint Presentation2009 1209 Asce Powerpoint Presentation
2009 1209 Asce Powerpoint Presentation
 
senior year portfolio small
senior year portfolio smallsenior year portfolio small
senior year portfolio small
 
Orica_Binder
Orica_BinderOrica_Binder
Orica_Binder
 
5.1 Mixed use building
5.1 Mixed use building5.1 Mixed use building
5.1 Mixed use building
 
portfolio june 24 finished portfolio
portfolio june 24 finished portfolioportfolio june 24 finished portfolio
portfolio june 24 finished portfolio
 
Police Station Design Concepts
Police Station Design ConceptsPolice Station Design Concepts
Police Station Design Concepts
 
R levine portfolio
R levine portfolioR levine portfolio
R levine portfolio
 
2013_TEO site
2013_TEO site2013_TEO site
2013_TEO site
 
Katie Johnson Portfolio
Katie Johnson PortfolioKatie Johnson Portfolio
Katie Johnson Portfolio
 
portfolio_2014
portfolio_2014portfolio_2014
portfolio_2014
 
CONSTRUCTION DOCS_FINAL TO PRINT
CONSTRUCTION DOCS_FINAL TO PRINTCONSTRUCTION DOCS_FINAL TO PRINT
CONSTRUCTION DOCS_FINAL TO PRINT
 
Cordy Commercial_Brochure_190x257_v20
Cordy Commercial_Brochure_190x257_v20Cordy Commercial_Brochure_190x257_v20
Cordy Commercial_Brochure_190x257_v20
 
Interior Design student work (Dezyne E' cole College)
Interior Design student work (Dezyne E' cole College)Interior Design student work (Dezyne E' cole College)
Interior Design student work (Dezyne E' cole College)
 
FINAL COMP BOOK
FINAL COMP BOOKFINAL COMP BOOK
FINAL COMP BOOK
 
5 Churchill Place
5 Churchill Place5 Churchill Place
5 Churchill Place
 
AIA COTE 2030: Skins 20121214
AIA COTE 2030: Skins 20121214AIA COTE 2030: Skins 20121214
AIA COTE 2030: Skins 20121214
 
QTO Sample
QTO SampleQTO Sample
QTO Sample
 

More from Tala Jazzy

Tala Jazzy Portfolio
Tala Jazzy PortfolioTala Jazzy Portfolio
Tala Jazzy PortfolioTala Jazzy
 
165 CHARLES ST,NY,NY
165 CHARLES ST,NY,NY165 CHARLES ST,NY,NY
165 CHARLES ST,NY,NYTala Jazzy
 
Falling water by frank lloyd
Falling water  by frank lloydFalling water  by frank lloyd
Falling water by frank lloydTala Jazzy
 
Architectural history
Architectural history Architectural history
Architectural history Tala Jazzy
 
Le castel béranger
Le castel bérangerLe castel béranger
Le castel bérangerTala Jazzy
 
Architectural History
Architectural History Architectural History
Architectural History Tala Jazzy
 
fire resistant assemblies
fire resistant assembliesfire resistant assemblies
fire resistant assembliesTala Jazzy
 
fire resistant assemblies
 fire resistant assemblies fire resistant assemblies
fire resistant assembliesTala Jazzy
 
Construction types
Construction typesConstruction types
Construction typesTala Jazzy
 
Means of egress
Means of egressMeans of egress
Means of egressTala Jazzy
 
Occupancy Load
Occupancy Load Occupancy Load
Occupancy Load Tala Jazzy
 
Sustainable design
Sustainable designSustainable design
Sustainable designTala Jazzy
 
Victorian House
Victorian House Victorian House
Victorian House Tala Jazzy
 
Doors and windows
Doors and windowsDoors and windows
Doors and windowsTala Jazzy
 
Building site and zoning
Building site and zoning Building site and zoning
Building site and zoning Tala Jazzy
 

More from Tala Jazzy (20)

Tala Jazzy Portfolio
Tala Jazzy PortfolioTala Jazzy Portfolio
Tala Jazzy Portfolio
 
165 CHARLES ST,NY,NY
165 CHARLES ST,NY,NY165 CHARLES ST,NY,NY
165 CHARLES ST,NY,NY
 
Hagia sophia
Hagia sophiaHagia sophia
Hagia sophia
 
Falling water by frank lloyd
Falling water  by frank lloydFalling water  by frank lloyd
Falling water by frank lloyd
 
Architectural history
Architectural history Architectural history
Architectural history
 
The rotunda
The rotundaThe rotunda
The rotunda
 
Le castel béranger
Le castel bérangerLe castel béranger
Le castel béranger
 
Architectural History
Architectural History Architectural History
Architectural History
 
fire resistant assemblies
fire resistant assembliesfire resistant assemblies
fire resistant assemblies
 
fire resistant assemblies
 fire resistant assemblies fire resistant assemblies
fire resistant assemblies
 
Construction types
Construction typesConstruction types
Construction types
 
Means of egress
Means of egressMeans of egress
Means of egress
 
Occupancy Load
Occupancy Load Occupancy Load
Occupancy Load
 
Sustainable design
Sustainable designSustainable design
Sustainable design
 
Ada
AdaAda
Ada
 
Victorian House
Victorian House Victorian House
Victorian House
 
roof systems
 roof systems  roof systems
roof systems
 
foundations
foundations foundations
foundations
 
Doors and windows
Doors and windowsDoors and windows
Doors and windows
 
Building site and zoning
Building site and zoning Building site and zoning
Building site and zoning
 

Recently uploaded

Call Girls Meghani Nagar 7397865700 Independent Call Girls
Call Girls Meghani Nagar 7397865700  Independent Call GirlsCall Girls Meghani Nagar 7397865700  Independent Call Girls
Call Girls Meghani Nagar 7397865700 Independent Call Girlsssuser7cb4ff
 
ARt app | UX Case Study
ARt app | UX Case StudyARt app | UX Case Study
ARt app | UX Case StudySophia Viganò
 
Passbook project document_april_21__.pdf
Passbook project document_april_21__.pdfPassbook project document_april_21__.pdf
Passbook project document_april_21__.pdfvaibhavkanaujia
 
Design Portfolio - 2024 - William Vickery
Design Portfolio - 2024 - William VickeryDesign Portfolio - 2024 - William Vickery
Design Portfolio - 2024 - William VickeryWilliamVickery6
 
NATA 2024 SYLLABUS, full syllabus explained in detail
NATA 2024 SYLLABUS, full syllabus explained in detailNATA 2024 SYLLABUS, full syllabus explained in detail
NATA 2024 SYLLABUS, full syllabus explained in detailDesigntroIntroducing
 
NO1 Famous Amil Baba In Karachi Kala Jadu In Karachi Amil baba In Karachi Add...
NO1 Famous Amil Baba In Karachi Kala Jadu In Karachi Amil baba In Karachi Add...NO1 Famous Amil Baba In Karachi Kala Jadu In Karachi Amil baba In Karachi Add...
NO1 Famous Amil Baba In Karachi Kala Jadu In Karachi Amil baba In Karachi Add...Amil baba
 
2024新版美国旧金山州立大学毕业证成绩单pdf电子版制作修改#毕业文凭制作#回国入职#diploma#degree
2024新版美国旧金山州立大学毕业证成绩单pdf电子版制作修改#毕业文凭制作#回国入职#diploma#degree2024新版美国旧金山州立大学毕业证成绩单pdf电子版制作修改#毕业文凭制作#回国入职#diploma#degree
2024新版美国旧金山州立大学毕业证成绩单pdf电子版制作修改#毕业文凭制作#回国入职#diploma#degreeyuu sss
 
在线办理ohio毕业证俄亥俄大学毕业证成绩单留信学历认证
在线办理ohio毕业证俄亥俄大学毕业证成绩单留信学历认证在线办理ohio毕业证俄亥俄大学毕业证成绩单留信学历认证
在线办理ohio毕业证俄亥俄大学毕业证成绩单留信学历认证nhjeo1gg
 
306MTAMount UCLA University Bachelor's Diploma in Social Media
306MTAMount UCLA University Bachelor's Diploma in Social Media306MTAMount UCLA University Bachelor's Diploma in Social Media
306MTAMount UCLA University Bachelor's Diploma in Social MediaD SSS
 
Abu Dhabi Call Girls O58993O4O2 Call Girls in Abu Dhabi`
Abu Dhabi Call Girls O58993O4O2 Call Girls in Abu Dhabi`Abu Dhabi Call Girls O58993O4O2 Call Girls in Abu Dhabi`
Abu Dhabi Call Girls O58993O4O2 Call Girls in Abu Dhabi`dajasot375
 
Call Us ✡️97111⇛47426⇛Call In girls Vasant Vihar༒(Delhi)
Call Us ✡️97111⇛47426⇛Call In girls Vasant Vihar༒(Delhi)Call Us ✡️97111⇛47426⇛Call In girls Vasant Vihar༒(Delhi)
Call Us ✡️97111⇛47426⇛Call In girls Vasant Vihar༒(Delhi)jennyeacort
 
Call Girls in Ashok Nagar Delhi ✡️9711147426✡️ Escorts Service
Call Girls in Ashok Nagar Delhi ✡️9711147426✡️ Escorts ServiceCall Girls in Ashok Nagar Delhi ✡️9711147426✡️ Escorts Service
Call Girls in Ashok Nagar Delhi ✡️9711147426✡️ Escorts Servicejennyeacort
 
办理学位证(NUS证书)新加坡国立大学毕业证成绩单原版一比一
办理学位证(NUS证书)新加坡国立大学毕业证成绩单原版一比一办理学位证(NUS证书)新加坡国立大学毕业证成绩单原版一比一
办理学位证(NUS证书)新加坡国立大学毕业证成绩单原版一比一Fi L
 
Introduction-to-Canva-and-Graphic-Design-Basics.pptx
Introduction-to-Canva-and-Graphic-Design-Basics.pptxIntroduction-to-Canva-and-Graphic-Design-Basics.pptx
Introduction-to-Canva-and-Graphic-Design-Basics.pptxnewslab143
 
定制(RMIT毕业证书)澳洲墨尔本皇家理工大学毕业证成绩单原版一比一
定制(RMIT毕业证书)澳洲墨尔本皇家理工大学毕业证成绩单原版一比一定制(RMIT毕业证书)澳洲墨尔本皇家理工大学毕业证成绩单原版一比一
定制(RMIT毕业证书)澳洲墨尔本皇家理工大学毕业证成绩单原版一比一lvtagr7
 
Revit Understanding Reference Planes and Reference lines in Revit for Family ...
Revit Understanding Reference Planes and Reference lines in Revit for Family ...Revit Understanding Reference Planes and Reference lines in Revit for Family ...
Revit Understanding Reference Planes and Reference lines in Revit for Family ...Narsimha murthy
 
How to Be Famous in your Field just visit our Site
How to Be Famous in your Field just visit our SiteHow to Be Famous in your Field just visit our Site
How to Be Famous in your Field just visit our Sitegalleryaagency
 
3D Printing And Designing Final Report.pdf
3D Printing And Designing Final Report.pdf3D Printing And Designing Final Report.pdf
3D Printing And Designing Final Report.pdfSwaraliBorhade
 
办理(宾州州立毕业证书)美国宾夕法尼亚州立大学毕业证成绩单原版一比一
办理(宾州州立毕业证书)美国宾夕法尼亚州立大学毕业证成绩单原版一比一办理(宾州州立毕业证书)美国宾夕法尼亚州立大学毕业证成绩单原版一比一
办理(宾州州立毕业证书)美国宾夕法尼亚州立大学毕业证成绩单原版一比一F La
 

Recently uploaded (20)

Call Girls Meghani Nagar 7397865700 Independent Call Girls
Call Girls Meghani Nagar 7397865700  Independent Call GirlsCall Girls Meghani Nagar 7397865700  Independent Call Girls
Call Girls Meghani Nagar 7397865700 Independent Call Girls
 
ARt app | UX Case Study
ARt app | UX Case StudyARt app | UX Case Study
ARt app | UX Case Study
 
Passbook project document_april_21__.pdf
Passbook project document_april_21__.pdfPassbook project document_april_21__.pdf
Passbook project document_april_21__.pdf
 
Design Portfolio - 2024 - William Vickery
Design Portfolio - 2024 - William VickeryDesign Portfolio - 2024 - William Vickery
Design Portfolio - 2024 - William Vickery
 
NATA 2024 SYLLABUS, full syllabus explained in detail
NATA 2024 SYLLABUS, full syllabus explained in detailNATA 2024 SYLLABUS, full syllabus explained in detail
NATA 2024 SYLLABUS, full syllabus explained in detail
 
NO1 Famous Amil Baba In Karachi Kala Jadu In Karachi Amil baba In Karachi Add...
NO1 Famous Amil Baba In Karachi Kala Jadu In Karachi Amil baba In Karachi Add...NO1 Famous Amil Baba In Karachi Kala Jadu In Karachi Amil baba In Karachi Add...
NO1 Famous Amil Baba In Karachi Kala Jadu In Karachi Amil baba In Karachi Add...
 
2024新版美国旧金山州立大学毕业证成绩单pdf电子版制作修改#毕业文凭制作#回国入职#diploma#degree
2024新版美国旧金山州立大学毕业证成绩单pdf电子版制作修改#毕业文凭制作#回国入职#diploma#degree2024新版美国旧金山州立大学毕业证成绩单pdf电子版制作修改#毕业文凭制作#回国入职#diploma#degree
2024新版美国旧金山州立大学毕业证成绩单pdf电子版制作修改#毕业文凭制作#回国入职#diploma#degree
 
在线办理ohio毕业证俄亥俄大学毕业证成绩单留信学历认证
在线办理ohio毕业证俄亥俄大学毕业证成绩单留信学历认证在线办理ohio毕业证俄亥俄大学毕业证成绩单留信学历认证
在线办理ohio毕业证俄亥俄大学毕业证成绩单留信学历认证
 
306MTAMount UCLA University Bachelor's Diploma in Social Media
306MTAMount UCLA University Bachelor's Diploma in Social Media306MTAMount UCLA University Bachelor's Diploma in Social Media
306MTAMount UCLA University Bachelor's Diploma in Social Media
 
Abu Dhabi Call Girls O58993O4O2 Call Girls in Abu Dhabi`
Abu Dhabi Call Girls O58993O4O2 Call Girls in Abu Dhabi`Abu Dhabi Call Girls O58993O4O2 Call Girls in Abu Dhabi`
Abu Dhabi Call Girls O58993O4O2 Call Girls in Abu Dhabi`
 
Call Us ✡️97111⇛47426⇛Call In girls Vasant Vihar༒(Delhi)
Call Us ✡️97111⇛47426⇛Call In girls Vasant Vihar༒(Delhi)Call Us ✡️97111⇛47426⇛Call In girls Vasant Vihar༒(Delhi)
Call Us ✡️97111⇛47426⇛Call In girls Vasant Vihar༒(Delhi)
 
Call Girls in Ashok Nagar Delhi ✡️9711147426✡️ Escorts Service
Call Girls in Ashok Nagar Delhi ✡️9711147426✡️ Escorts ServiceCall Girls in Ashok Nagar Delhi ✡️9711147426✡️ Escorts Service
Call Girls in Ashok Nagar Delhi ✡️9711147426✡️ Escorts Service
 
Call Girls in Pratap Nagar, 9953056974 Escort Service
Call Girls in Pratap Nagar,  9953056974 Escort ServiceCall Girls in Pratap Nagar,  9953056974 Escort Service
Call Girls in Pratap Nagar, 9953056974 Escort Service
 
办理学位证(NUS证书)新加坡国立大学毕业证成绩单原版一比一
办理学位证(NUS证书)新加坡国立大学毕业证成绩单原版一比一办理学位证(NUS证书)新加坡国立大学毕业证成绩单原版一比一
办理学位证(NUS证书)新加坡国立大学毕业证成绩单原版一比一
 
Introduction-to-Canva-and-Graphic-Design-Basics.pptx
Introduction-to-Canva-and-Graphic-Design-Basics.pptxIntroduction-to-Canva-and-Graphic-Design-Basics.pptx
Introduction-to-Canva-and-Graphic-Design-Basics.pptx
 
定制(RMIT毕业证书)澳洲墨尔本皇家理工大学毕业证成绩单原版一比一
定制(RMIT毕业证书)澳洲墨尔本皇家理工大学毕业证成绩单原版一比一定制(RMIT毕业证书)澳洲墨尔本皇家理工大学毕业证成绩单原版一比一
定制(RMIT毕业证书)澳洲墨尔本皇家理工大学毕业证成绩单原版一比一
 
Revit Understanding Reference Planes and Reference lines in Revit for Family ...
Revit Understanding Reference Planes and Reference lines in Revit for Family ...Revit Understanding Reference Planes and Reference lines in Revit for Family ...
Revit Understanding Reference Planes and Reference lines in Revit for Family ...
 
How to Be Famous in your Field just visit our Site
How to Be Famous in your Field just visit our SiteHow to Be Famous in your Field just visit our Site
How to Be Famous in your Field just visit our Site
 
3D Printing And Designing Final Report.pdf
3D Printing And Designing Final Report.pdf3D Printing And Designing Final Report.pdf
3D Printing And Designing Final Report.pdf
 
办理(宾州州立毕业证书)美国宾夕法尼亚州立大学毕业证成绩单原版一比一
办理(宾州州立毕业证书)美国宾夕法尼亚州立大学毕业证成绩单原版一比一办理(宾州州立毕业证书)美国宾夕法尼亚州立大学毕业证成绩单原版一比一
办理(宾州州立毕业证书)美国宾夕法尼亚州立大学毕业证成绩单原版一比一
 

Work samples TALA JAZZY

  • 2. WARBY PARKER: 1258 6TH AVE ROCKEFELLER CENTER Design Progress – 21 July 2017
  • 3. “ “ Radio City Music Hall was to be a palace for the people. A place of beauty offering high-quality entertainment at prices ordinary people could afford.
  • 4.
  • 5. WARBY PARKER Direction I + II - Ground Floor Plan Customer Elevator OPEN BACK FIXTURE AT STREET FACING WINDOW BRASS INL AY COVERED WINDOW (ACCESSIBLE) WOOD STAIRS TO SECOND FLOOR ACCESSIBLE STORAGE18 PRODUCT BAYS (GCT:18 PRODUCT BAYS) 5
  • 6. Direction I - Ceiling Plan WARBY PARKER PAINTED DRYWALL DOME. (NOTE: DOME COVERS 50TH STREET FACING WINDOWS) BLUE L ACQUERED PANELS WITH (6) RECESSED FIXTURES 6 This ceiling plan will updated to a simpler configuration
  • 7. WARBY PARKER Direction I + II - Second Floor Plan EXAM ROOM 2 EXAM ROOM 1 PRE-TESTING ROOM BENCH SEATING AND TABLES (MODUL AR) CUSTOMER LOUNGE CUSTOMER LOUNGE (CHEVRON OPTION) FULL HEIGHT PARTITION 7 We are reviewing additional floor finish options
  • 8. Rockefeller Center Direction I + II - Third Floor Plan WARBY PARKER TRAINING ROOM MANAGERS OFFICE OPS COUNTER LVT FLOORING THROUGHOUT BOH 8
  • 9. Direction I - Elevation WARBY PARKER WHITE L ACQUER LIBRARY PRODUCT BAYS WITH LIGHT OAK INTERIOR. WHITE STAINED OAK PANELING AT REF DESK. OPEN BACK AT WINDOW. WHITE STAINED OAK PANELING AT ELEV. SURROUND COLOR BLOCKING WINDOW TREATMENTS 9
  • 10. Direction I - Elevation WARBY PARKER STORAGE PARTIALLY OPEN PRE-TESTING ROOM. TO EXAM ROOM (PL ACEHOLDER ARTWORK) PL ACEHOLDER ARTWORK AT EYE EXAM ROOMS WALLS WHITE STAINED OAK PANELING AT REF DESK. 10
  • 11. Direction I - Ref Desk Elevation WARBY PARKER WALNUT BENCH PL ACEHOLDER REF DESK, FRAMED ARTWORK AND EYE EXAM SIGNAGE 11
  • 12. Direction I - Store Section View I WARBY PARKER12
  • 13. Direction I - Store View II WARBY PARKER 25July 21, 2017 13
  • 14. WARBY PARKER14 SALES FLOOR - MODUL AR TABLES (SHOWN WITHOUT BENCH AT ROCK CENTER) Direction I - Sales Tables
  • 15. WARBY PARKER41 FF&E - Bench SECOND FLOOR WINDOW BENCH (UPHOLSTERY TBC; TIE INTO PRODUCT LEATHER)
  • 16. October 16, 2017 UNION STATION Storefront Elevation 9 ¼” Hanging unlit signage New 180 degree swing doors Mall standard finishes Mall standard blade sign Mall Storefront Metal
  • 17. October 16, 2017 UNION STATION Interior Wall Elevations Customer seating near exam room CPU TERMINAL CONCOURSE TERMINAL CONCOURSE BOH EXAM ROOM Warby Custom ‘Reading Positions’ Wallcovering
  • 18. October 16, 2017 UNION STATION Colors and Materials General Paint- Oxford White Ceiling Panel- Old Pick Up Truck Blue Option Grigio Tucci Marble Reference Desk- Gray Metal Detail- Brushed Brass Library Cabinet- Clear Rift Oak Selling Table- Walnut Leather Flooring- White Terrazzo Flooring- Grey Terrazzo
  • 20.
  • 21. COVER SHEET 40 MASSACHUSETTS AVE. NE WASHINGTON DC 20002 SUITE: 112 P-1 SUITE: 112 40 MASSACHUSETTS AVE. NE WASHINGTON DC 20002
  • 22. 40 MASSACHUSETTS AVE. NE WASHINGTON DC 20002 SUITE: 112
  • 23. SPECIFICATIONS 40 MASSACHUSETTS AVE. NE WASHINGTON DC 20002 SUITE: 112
  • 24. SPECIFICATIONS 40 MASSACHUSETTS AVE. NE WASHINGTON DC 20002 SUITE: 112
  • 25. COMPUTER DIE-CUT VINYL DIRECT VIEW FOR OPAQUE SURFACES. REVERSE VIEW FOR APPLICATION ON SURFACE OF TRANSPARENT SURFACES. COLOR: INTERNATIONAL BLUE LC CL FIELD WITH TEXT AND GRADE 2 BRAILLE OF ABOVE TEXT 5/8" HIGH MIN. TYPE RAISED 1/32" MIN. HELVETICA MEDIUM UPPERCASE LETTERS LC TACTILE EXIT SIGNAGE FIELD WITH TEXT AND GRADE 2 BRAILLE OF ABOVE TEXT 5/8" HIGH MIN. TYPE RAISED 1/32" MIN. HELVETICA MEDIUM UPPERCASE LETTERS LC TACTILE EXIT SIGNAGE CL LC LC SIDE VIEW 12" TYP. 12" TYP. SIDE VIEW SIGN SIGN CL 1/4" THICK 60"AF.F. FLOOR,TYP. 1/4" THICK OF TOILET ENTRY DOORS, TYP. 60"AF.F. FLOOR,TYP. 60"AF.F. FLOOR,TYP. FIELD WITH SYMBOLS 60"AF.F. FLOOR,TYP. FIELD WITH SYMBOLS 5/8" HIGH MIN. TYPE RAISED 1/32" MIN. HELVETICA MEDIUM UPPERCASE LETTERS FIELD WITH TEXT AND GRADE 2 BRAILLE OF ABOVE TEXT 60"AF.F. FLOOR,TYP. 60"AF.F. FLOOR,TYP. E F WHEN PERMANENT IDENTIFICATION IS PROVIDED FOR ROOMS AND SPACES, RAISED LETTERS SHALL BE PROVIDED AND SHALL BE ACCOMPANIED BY BRAILLE IN CONFORMANCE WITH SECTION 4.30.4 OF THE ADA. SIGNS SHALL BE INSTALLED ON THE WALL ADJACENT TO THE LATCH OUTSIDE OF THE DOOR. WHERE THERE IS NO WALL SPACE ON THE LATCH SIDE, INCLUDING AT DOUBLE LEAF DOORS, SIGNS SHALL BE PLACED ON THE NEAREST ADJACENT WALL, PREFERABLY ON THE RIGHT. MOUNTING HEIGHT SHALL BE 60" ABOVE THE FINISHED FLOOR TO THE CENTERLINE OF THE SIGN. MOUNTING LOCATION SHALL BE DETERMINED SO THAT A PERSON MAY APPROACH WITHIN 3" OF SIGNAGE WITHOUT ENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN THE SWING OF A DOOR. SEC. 4.30.6 OF THE ADA. SIGNS & IDENTIFICATION: ENTIRE FACILITY SHALL CONFORM TO THE MINIMUM REQUIREMENT OF THE AMERICAN WITH DISABILITY ACT (ADA), ACCESSIBILITY STANDINGS AND ALL LOCAL GOVERNING REGULATIONS. 5/8" HIGH MIN. TYPE RAISED 1/32" MIN. HELVETICA MEDIUM UPPERCASE LETTERS FIELD WITH TEXT AND GRADE 2 BRAILLE OF ABOVE TEXT 60"MIN 18" MIN 48"MIN. 12" MIN. 60"MIN. 36" 42"MIN. 54" MIN. 48"MIN. 24" 48"MIN. 42"MIN. Y 24" MIN. 24" (610 mm) PREFERRED 32" MIN. 24" MAX. 48"MIN. 48"MIN. 60" DIA. 36" 60" 24" 12" 36" 48" 48" 48" X Z Y X 30" 30" 15"MIN. 32-42"PREFERRED 48"MAX. HIGH FORWARD REACH LIMIT MAXIMUM FORWARD REACH OVER AN OBSTRUCTION NOTE Z SHALL BE X, WHEN X20 IN., THEN Y SHALL BE 48 IN. MAXIMUM. WHEN X IS 20 TO 25 IN., THEN Y SHALL BE 44 IN. MAXIMUM. 18"MIN. 1 1 4" - 2"Ø 1 1 2" MIN. 1-1/2" MIN. 1 1 2" MIN. 1 1 2" MIN. 1 1 4" - 2"Ø 1-1/4" TO 1-1/2" 60" MIN. 56"MIN. 42" MIN. 18" MIN 36" 6" 33-36" 39"-41"18" 18" CL24" MIN 6" MAX. TOE CLEARANCE 8" MIN. KNEE CLEARANCE 9" MIN. 34"MAX. 27"MIN. 17" MIN. DEPTH 29"MIN CLEARANCE AT DRINKING FOUNTAIN 10 17 - 19" EQUIPMENT PERMITTED IN SHADED AREA 8" MIN. 6" MIN. 9" MIN. 36" 29" 17 - 19" 24" 48" MIN. 36" MIN. 60" MIN. 32" MIN. 2'-0" 48" MIN. 48" 30"10" MAX. SLOPE SHALL NOT EXCEED 1:48 CLEARANCE AT LAVATORY9 48"MIN. 30" MIN. 19" MAX. 17"MIN. CLEAR FLOOR SPACE 8" MIN CL 33" 19" (MIN.) 17"-19" 12" 42" 12" MAX 39"-41" MIN. 39"-41"18" CL 54" MIN 36" MAX HAND RAIL/GRAB BAR7 FORWARD REACH RANGES 5 SIDE REACH RANGES 6 TURNING SPACE 4 MIN. FLOOR WIDTH CLEARANCE 3 DOOR IN SERIES 2 DOOR CLEARANCES1 SHELVES CLOSET 21" MAX. 48"MAX.48"MAX. 21" MAX.9" MIN. 30"24" 34"MAX. 46" 30" 10" MAX. 32-42"PREFERRED 15"MIN. 48"MAX. UNOBSTRUCTED REACH 18"CL 28" MIN 18" MIN CL 12"MAX 54"MIN 24" MIN 48"MIN 60" MIN DIA CLEAR 18" MIN TACTILE EXIT SIGNAGE FIELD WITH TEXT AND GRADE 2 BRAILLE OF ABOVE TEXT 5/8" HIGH MIN. TYPE RAISED 1/32" MIN. HELVETICA MEDIUM UPPERCASE LETTERS LC LC FIELD WITH SYMBOLS 60"AF.F. FLOOR,TYP. 60"AF.F. FLOOR,TYP. D 5/8" HIGH MIN. TYPE RAISED 1/32" MIN. HELVETICA MEDIUM UPPERCASE LETTERS FIELD WITH TEXT AND GRADE 2 BRAILLE OF ABOVE TEXT LC CL SEE 12" TYP. 12"TYP. SIDE VIEW SIGN SEE 1/4" THICK 60"AF.F. FLOOR,TYP. 5B 5A GENERAL ACCESSIBILITY GUIDELINES CLEAR FLOOR SPACE @ WATER CLOSET8A TYPICAL SIGN REQUIREMENTS & NOTES TYPICAL DIMENSION INFORMATION SINGLE ACCOMADATION TOILET FACILITY8 40 MASSACHUSETTS AVE. NE WASHINGTON DC 20002 SUITE: 112
  • 26. DEMOLITION PLAN AND NOTES 40 MASSACHUSETTS AVE. NE WASHINGTON DC 20002 SUITE: 112 1 D1.0
  • 27. BREAK COUNTER ULINE ULINE FIXTURE PLAN, FIXTURE SCHEDULE AND NOTES 40 MASSACHUSETTS AVE. NE WASHINGTON DC 20002 SUITE: 112 1 F1.0
  • 28. CONSTRUCTION PLAN, WALL TYPES, AND NOTES P-1 40 MASSACHUSETTS AVE. NE WASHINGTON DC 20002 SUITE: 112 1 A1.0 2 A1.0
  • 29. LVTCERAMIC TILE ALIGN FLOOR FINISH CHANGE W/SIDE OF DOOR JAMB DOOR AND JAMB ZERO BRASS SADDLE MODEL:#164B OR EQUAL SEALANT JOINT CERAMIC TO LVT TERRAZZO TILE LVT TERRAZZO TO LVT TERRAZZO TILE ON MORTAR SETTING BED CERAMIC TERRAZZO TILE TO CERAMIC TERRAZZO TILE ON MORTAR SETTING BED TERRAZZO TILE TO TERRAZZO TILE DOOR AND JAMBDOOR AND JAMBDOOR AND JAMB LVTLVT DOOR AND JAMB LVT TO LVT FINISH PLAN, FINISH SCHEDULE, AND GENERAL NOTES 40 MASSACHUSETTS AVE. NE WASHINGTON DC 20002 SUITE: 112 2 A2.0 1 A2.0
  • 30. SP SP SP SP REFLECTED CEILING PLAN, LIGHT FIXTURE SCHEDULE, AND NOTES 40 MASSACHUSETTS AVE. NE WASHINGTON DC 20002 SUITE: 112 1 A3.0 2 A3.0
  • 31. SP SP SP SP MD CR DC CR MD DC CR POWER AND COMMUNICATION PLAN 40 MASSACHUSETTS AVE. NE WASHINGTON DC 20002 SUITE: 112 1 A3.1 2 A3.1
  • 32. 2 A4.0 40 MASSACHUSETTS AVE. NE WASHINGTON DC 20002 SUITE: 112 2 A4.0 3 A4.0 1 A4.0 4 A4.0
  • 33. REFERENCE DESK SALES FLOOR INTERIOR ELEVATIONS 40 MASSACHUSETTS AVE. NE WASHINGTON DC 20002 SUITE: 112 1 A4.1 2 A4.1 3 A4.1 4 A4.1
  • 34. BACK OF HOUSE, MANAGER'S OFFICE & EXAM ROOM INTERIOR ELEVATIONS 40 MASSACHUSETTS AVE. NE WASHINGTON DC 20002 SUITE: 112 1 A4.2 2 A4.2 3 A4.2 4 A4.2 5 A4.2 6 A4.2 7 A4.2 8 A4.2 9 A4.2
  • 35. SCALE:A EZY JAMB DETAIL - EXAM ROOM N.T.S. SCALE:C TYPICAL DOOR HEAD N.T.S. SCALE:D TYPICAL DOOR JAMB N.T.S. 40 MASSACHUSETTS AVE. NE WASHINGTON DC 20002 SUITE: 112 1 A5.0 SCALE:E BLIND PIVOT DOOR HEADER N.T.S. SCALE:B EZY JAMB DETAIL - STOCK/ SALES DOOR N.T.S.
  • 36. 40 MASSACHUSETTS AVE. NE WASHINGTON DC 20002 SUITE: 112 1 A6.0 2 A6.0
  • 37.
  • 38. INTERIOR TENANT IMPROVEMENT / FIT-OUT STORE NO. US (BLUE) 2018 BRANSON LANDING, BUILDING 1000 SPACE NO. 1003 - 1013 100 BRANSON LANDING BLVD BRANSON, MO 65616 SITE INFORMATION: BRANSON LANDING SPACE NO. 1003-1013 100 BRANSON LANDING BLVD BRANSON, MO 65616 KEY PLAN (N.T.S.) THESE PLANS COMPLY WITH THE PROVISION OF TITLE III OF THE "AMERICANS WITH DISABILITIES ACT" (ADA) PUBLIC LAW 101-336, FOR HANDICAPPED ACCESSIBILITY FOR CUSTOMER AND EMPLOYEES. ALL WORK DONE UNDER THIS CONTRACT SHALL COMPLY WITH THE PROVISIONS OF THE SPECIFICATIONS, DRAWINGS & CONSTRUCTION CRITERIA OF THE LANDLORD, AND SHALL SATISFY ALL APPLICABLE CODES, ORDINANCES, AND REGULATIONS OF ALL GOVERNING BODIES INVOLVED. ANY MODIFICATIONS TO THE CONTRACT WORK REQUIRED BY SUCH AUTHORITIES SHALL BE PERFORMED BY THE GENERAL CONTRACTOR. ALL PERMITS AND LICENSES NECESSARY FOR THE EXECUTION OF THE WORK SHALL BE SECURED AND PAID FOR BY THE GENERAL CONTRACTOR. THESE PLANS ARE IN CONFORMANCE WITH THE FOLLOWING CODES: LOCATION PLAN (N.T.S.) BUILDING: PLUMBING: MECHANICAL: ELECTRICAL: ACCESSIBILITY: FIRE SAFETY CODE: NORTH AREA CALCULATIONS GROSS SQUARE FOOTAGE SALES AREA: DISPLAY/POSTER & OPEN WINDOWS: FITTING ROOMS AREAS: TOILET ROOMS: BACK OF HOUSE AREAS: STOCK ROOM/VISUAL AREA: TOTAL: NET SQUARE FOOTAGE SALES AREA: DISPLAY/POSTER & OPEN WINDOWS: FITTING ROOMS AREAS: TOILET ROOMS: BACK OF HOUSE AREAS: STOCK ROOM/VISUAL AREA: TOTAL: 15,488 SF 1,813 SF 929 SF 161 SF 1,153 SF 1,648 SF 21,192 SF 14,944 SF 1,758 SF 756 SF 145 SF 717 SF 1,475 SF 19, 795 SF LIST OF DRAWINGSDWG. # REVISED & ISSUED ISSUED E-000 E-210 E-211 E-310 E-410 E-411 E-412 E-501 E-502 E-601 E-602 E-701 E-702 E-703 E-704 E-705 E-706 E-800 E-901 M-000 M-210 M-500 M-700 M-800 M-901 M-902 P-500 P-900 ELECTRICAL LEGENDS, NOTES AND DETAILS GENERAL LIGHTING PLAN TRACK LIGHTING PLAN POWER PLAN AUDIO PLAN SECURITY PLAN FIRE ALARM PLAN ENLARGED BOH POWER PLANS ENLARGED POWER PLANS POWER RISER DIAGRAM PANEL SCHEDULES EMS DETAILS POWERLINK CONTROLS ELECTRICAL DETAILS FIRE ALARM RISER NOTES AND DETAILS SECURITY DETAILS BACK OF HOUSE ELEVATIONS LIGHTING FIXTURE SCHEDULE ELECTRICAL SPECIFICATIONS MECHANICAL TITLE SHEET HVAC PLAN ENLARGED BOH HVAC PLAN HVAC DETAILS HVAC SCHEDULES MECHANICAL SPECIFICATIONS MECHANICAL COMMISSIONING SPECIFICATIONS/FORMS ENLARGED PLUMBING PLAN AND DETAILS PLUMBING SPECIFICATIONS FIRE PROTECTION PLAN FIRE PROTECTION SPECIFICATIONS FP-210 FP-900 LANDLORD'S REPRESENTATIVE HCW 153 SOUTH PAYNE STEWART DRIVE BRANSON, MO 65616 TEL: 417-332-3438 CONTACT: BARRY SCHWARTZ TITLE: EXECUTIVE VICE PRESIDENT/CFO E-MAIL: BSCHWARTZ@HCW.US TITLE SHEET GENERAL NOTES AND RESPONSIBILITY SCHEDULE EGRESS PLANS CONSTRUCTION PLANS DIMENSION PLANS CONSTRUCTION PLAN GENERAL AND KEY NOTES REFLECTED CEILING PLANS CEILING COORDINATION PLANS FIXTURE PLANS FIXTURE SCHEDULE FINISH PLANS FINISH PLAN LEGENDS AND NOTES GRAPHIC DETAILS NAVIGATION SIGN DETAILS ENLARGED STOREFRONT PLANS AND ELEVATIONS ENLARGED STOREFRONT PLANS, ELEVATIONS AND DETAILS STOREFRONT SECTIONS STOREFRONT SECTIONS STOREFRONT SECTIONS STOREFRONT DETAILS SIGNAGE DETAILS INTERIOR ELEVATIONS INTERIOR ELEVATIONS INTERIOR ELEVATIONS INTERIOR ELEVATIONS PARTITION TYPES PARTITION TYPES AND BOX BEAM DETAILS FIXTURE, CASHWRAP AND MISC. DETAILS FLOORING AND BASE DETAILS COLUMN ENCLOSURE DETAILS AND ELEVATIONS COLUMN AND PORTAL DETAILS CEILING DETAILS FITTING ROOM AREA #1 & #2 ENLARGED PLANS AND ELEVATIONS FITTING ROOM DETAILS ENLARGED BOH PLAN, NOTES AND SCHEDULES BOH MILLWORK DETAILS AND ELEVATIONS BOH MILLWORK DETAILS AND ELEVATIONS TOILET ROOM AND JANITOR'S CLOSET PLAN AND ELEVATIONS DOOR SCHEDULE DOOR DETAILS SPECIFICATIONS SPECIFICATIONS SPECIFICATIONS A-000 A-010 A-110 A-210 A-211 A-212 A-310 A-311 A-410 A-421 A-510 A-511 A-550 A-551 A-600 A-601 A-602 A-603 A-604 A-608 A-609 A-610 A-611 A-612 A-613 A-700 A-701 A-702 A-710 A-711 A-712 A-720 A-730 A-731 A-740 A-741 A-742 A-743 A-800 A-801 A-930 A-931 A-932 H&M STORE NO. US667 BRANSON LANDING SPACE NO. 1003-1013 100 BRANSON LANDING BLVD BRANSON, MO 65616 12.18.17CLIENT/LANDLORDREVIEW CODE ANALYSISPROJECT DIRECTORY LIST OF DRAWINGS BUILDING DEPARTMENT CITY OF BRANSON 110 WEST MADDUX BRANSON, MO 65616 TEL: (417)-334-3345 EXISTING TENANT'S TO BE RE-DEMISED (BY H&M) SPACE # 1003 - CHICO'S SPACE # 1005 - VACANT SPACE # 1007-1013 - VACANT *REFER TO LANDLORD'S DRAWINGS FOR SCOPE OF WORK PERTAINING TO SHELL BLDG. / RE-DEMISE OF EXISTING SPACES NORTH 2015 INTERNATIONAL BUILDING CODE (WITH LOCAL AMENDMENTS) 2015 INTERNATIONAL PLUMBING CODE (WITH LOCAL AMENDMENTS) 2015 INTERNATIONAL MECHANICAL CODE (WITH LOCAL AMENDMENTS) 2014 NATIONAL ELECTRICAL CODE (WITH LOCAL AMENDMENTS) ICC/ANSI A117.1-2009 EDITION 2015 INTERNATIONAL FIRE CODE USE GROUP: M - MERCANTILE (309.1) S-1 - STORAGE (311.2) SEPARATED OCCUPANCIES (508.4/508.4) CONSTRUCTION TYPE: II A PROTECTED NON-COMBUSTIBLE (SECTION 601, TABLE 601) OCCUPANT LOAD (APPLICABLE TABLE): SALES AREA (GRADE FLOOR) + DISPLAY/POSTER & OPEN WINDOWS + FITTING ROOMS + TOILET ROOMS: STOCK ROOM + VISUAL AREA + NIGHTBOX + REMOTE NIGHTBOX: TOTAL OCCUPANT LOAD: 18,391 / 60 SF PER PERSON = 306 PEOPLE 2,801 / 300 SF PER PERSON = 9 PEOPLE = 315 PEOPLE NUMBER OF EXITS PROPOSED: (2) EXITS PROVIDED: 204" (17'-0"), 44" WIDE MIN. PATH 30" MIN. (SECTION 1018.4) PROPOSED: 1 MALE, 1 FEMALE (FOR EMPLOYEE USE) 1 MALE, 1 FEMALE (FOR EMPLOYEE USE) 1 HI-LO TYPE 1 REQUIRED: 1 MALE, 1 FEMALE 1 MALE, 1 FEMALE 1 1 EXIT REQUIREMENTS: (SECTION 1022.1): NUMBER OF EXITS REQUIRED: (2) EXITS FOR OCCUPANT LOAD OF 1 - 500 EXIT WIDTH REQ'D. (SECTION 1005.3.2): 0.2" PER OCCUPANT x 315 OCCUPANTS = 63" MIN. AISLE WIDTH REQ'D.: MIN. PLUMBING FIXTURE REQUIREMENTS: (IPC, TABLE 403.1) DISTANCE TO PUBLIC FACILITIES (SECTION 403.3.4): > 300' PLUMBING FACILITIES WITHIN TENANT SPACE ARE EMPLOYEE FACILITIES ONLY (SECTION 403.3.4) MAX. NUMBER OF EMPLOYEES AT A TIME; 18 PEOPLE FIXTURE: WATER CLOSET LAVATORY DRINKING FOUNTAIN SERVICE SINK REVISED & ISSUED ISSUED LIST OF DRAWINGS H&M STORE NO. US667 BRANSON LANDING SPACE NO. 1003-1013 100 BRANSON LANDING BLVD BRANSON, MO 65616 LIST OF DRAWINGSDWG. # VENDOR LIST 12.18.17CLIENT/LANDLORDREVIEW TENANT H&M HENNES & MAURITZ 110 FIFTH AVENUE, 11TH FLOOR NEW YORK, NY 10011 TEL: 347-835-7856 CONTACT: KATIE HWANG TITLE: PROJECT MANAGER EMAIL: KATIE.HWANG@HM.COM ARCHITECT SARGENTI ARCHITECTS ROBERT SARGENTI, PRINCIPAL ARCHITECT 461 FROM ROAD, 2ND FLOOR PARAMUS, NJ 07652 TEL: 973-253-9393 CONTACT: ALICE PINTO TITLE: SENIOR PROJECT MANAGER E-MAIL: APINTO@SARGARCH.COM * EAS CONTROLTEK 95 DERMODY STREET CRANFORD, NJ 07016 TEL: 888-808-6970 CONTACT: STEVE SELL E: STEVE.SELL@CONTROLTEKUSA.COM CONTACT: STEFANIE HOOVER E. STEFANIE.HOOVER@CONTROLTEKUSA.COM BURGLAR ALARM FE MORAN 201 W. UNIVERSITY AVE. CHAMPAIGN, IL, 61821 TEL: 217-403-6444 CONTACT: JANNA CAPUTO HILL TITLE: PROJECT MANAGER E: JSTEFFAN@FEMORANSECURTIY.COM CCTV S-TRON 1227 WALT WHITMAN RD MELVILLE, NY, 11747 TEL: 860-668-7777 CONTACT: BOB KASPERSKI TITLE: PROJECT MANAGER E-MAIL: BKASPERSKI@S-TRON.COM BMS SYSTEM T-WAVE 1012 CENTRAL AVE S. KENT, WA 98032 253-867-2333 CONTACT: JERRY SCOTT E: JERRY.S@TWAVETECH.COM AUDIO/SPEAKERS (RECOMMENDED VENDOR) ECI 3100 NW BOCA RATON BLVD. SUITE 106 BOCA RATON, FL 33431 TEL: 561-416-5880 CONTACT: BART RENO E: RENO0369@YAHOO.COM IT SYSTEM H&M 3000 LIGHTNING WAY - 1ST FLR SECAUCUS, NJ 07094 TEL: 646-321-2897 CONTACT: MARC DAVIS TITLE: IT-PROJECT MANAGEMENT E-MAIL: MARC.DAVIS@HM.COM CONTACT: KAMRAN JAVED SAFE WIILSON SAFE 3031 ISLAND AVENUE PHILADELPHIA, PA 19153 TEL: 800-345-8053 CONTACT: BOB KASSOFF TITLE: SALES E-MAIL: RKASSOFF@WILSONSAFE.COM AUDIO/SPEAKERS (RECOMMENDED VENDOR) DIGITRON CONTACT: JIM ANKER E: JIM@DIGITRON.NET AUDIO/SPEAKERS (RECOMMENDED VENDOR) MOOD MEDIA CONTACT: CRAIG BREIGLE E: CRAIG.BREIGLE@MOODMEDIA.COM SIGNAGE JONES SIGN 400 MACK DRIVE CROYDON, PA 19021 TEL: 609-458-6807 CONTACT: NELLIE MCDERMOTT TITLE: REGIONAL VP NATIONAL SALES E: NMCDERMOTT@JONESSIGN.COM CUBE S-TRON 1227 WALT WHITMAN RD MELVILLE, NY, 11747 TEL: 860-668-7777 CONTACT: BOB KASPERSKI TITLE: PROJECT MANAGER E-MAIL: BKASPERSKI@S-TRON.COM REMOTE NIGHT BOX REVISION: SHEET TITLE: SPACE NO.: ARCH PROJECT NO.: SCALE: DRAWN BY: REV. NO: SHEET NO: PRODUCT SEASON: 2018 US667-BLUE BRANSONLANDING BUILDING1000 SPACENOS.1003-1013 100BRANSONLANDINGBLVD BRANSON,MOZIP65616 AS NOTED 2018 2187-17 ISSUE DATE: 1003-1013 D.O.B. NO: 12.18.17 CLIENT/LANDLORD REVIEW 4 6 1 F R O M R O A D PARAMUS, NJ 07652 973.253.9393 TEL 973.253.9390 FAX WWW.SARGARCH.COM VP A-000 TITLE SHEET
  • 39. GENERAL CONDITIONS SECTIONELEVATION SECTION DETAIL PLAN DETAIL X PARTITION TYPE COLUMN TAG FINISH TAG X REVISION CLOUD ALL WORK IS TO CONFORM TO ALL APPLICABLE CODES AND REGULATIONS. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL REQUIRED PERMITS AND APPROVALS PRIOR TO COMMENCEMENT OF WORK. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL REQUIRED INSPECTIONS AND CERTIFICATES. THE CONTRACTOR WILL BECOME FAMILIAR WITH EXISTING CONDITIONS AND SHALL VERIFY EXISTING FIELD CONDITIONS IN THE FIELD PRIOR TO COMMENCEMENT OF THE WORK, AND SHALL REPORT ANY DISCREPANCIES BETWEEN THE DRAWINGS AND FIELD CONDITIONS TO THE ARCHITECT. FOR GENERAL CONDITIONS REFER TO AIA DOCUMENT A107 2007. ALL WORK TO BE WARRANTED FOR A PERIOD NO LESS THAN ONE YEAR. THE CONTRACTOR SHALL COORDINATE ALL WORK PROCEDURES WITH REQUIREMENTS OF LOCAL AUTHORITIES AND BUILDING MANAGEMENT. ALL ELECTRICIANS AND PLUMBERS INVOLVED IN THE WORK ARE TO BE LICENSED AND BONDED. ELECTRICAL WORK SHALL BE FILED SEPARATELY BY THE ELECTRICAL SUBCONTRACTOR. DEMOLITION IS TO BE PERFORMED IN AN ORDERLY MANNER, PER THE RESTRICTIONS, REGULATIONS, AND HOURS SET BY THE BUILDING MANAGEMENT. DEBRIS IS TO BE DISCARDED OFF SITE IN A PROPER MANNER AND NOT BE ALLOWED TO ACCUMULATE IN THE WORK AREA. DIMENSIONS GIVEN ARE TO FINISH SURFACES UNLESS NOTED OTHERWISE. THE CONTRACTOR SHALL LAY OUT HIS OR HER OWN WORK, AND SHALL PROVIDE ALL DIMENSIONS REQUIRED FOR OTHER TRADES (PLUMBING, ELECTRICAL, ETC...) G.C. TO CHECK WITH LANDLORD FOR TYPE OF CONNECTIONS & POINT ATTACHMENT TO EXISTING STRUCTURE AND SLAB PRIOR TO PERFORM WORK. G.C. TO COORDINATE WITH ALL H & M VENDORS AND SUPERVISORS AT JOB SITE. G.C. AND HIS FLOOR CONTRACTORS TO INSPECT FLOOR AT TIME OF H & M POSSESSION OF SPACE FROM LANDLORD & ADVISE H & M OF ANY PROBLEMS OR DEFICIENCIES. G.C. TO SCHEDULE H&M VENDOR DELIVERIES WITH H&M PROJECT MANAGER. PROPOSED WORK TO COMPLY WITH APPLICABLE REQUIREMENTS OF LOCAL LAWS FOR HANDICAPPED ACCESS. TOILET ROOMS TO COMPLY WITH THE APPLICABLE REQUIREMENTS OF LOCAL LAWS FOR HANDICAPPED ACCESSIBILITY. ACCESSIBLE ROUTES TO BE PROVIDED, PROVIDING A MINIMUM OF 32 INCHES OF WIDTH AT DOORWAYS. EMERGENCY WARNING SYSTEMS SHALL INCLUDE BOTH AUDIBLE AND VISUAL ALARMS AS PER CODE REQUIREMENTS. PROPOSED STORAGE FACILITIES SUCH AS CABINETS, SHELVES, CLOSETS, AND DRAWERS SHALL COMPLY WITH APPLICABLE REQUIREMENTS OF H.C. ACCESSIBILITY OF LOCAL LAWS : A. CLEAR FLOOR SPACE OF A MINIMUM OF 30 INCHES BY 48 INCHES SHALL BE PROVIDED FOR APPROACH TO ALL STORAGE FACILITIES. B. STORAGE SPACES SHALL COMPLY WITH AT LEAST ONE OF THE REACH RANGES SPECIFIED IN H.C. APPLICABLE ACCESSIBILITY CODES. CLOTHES RODS SHALL BE A MAXIMUM OF 54 INCHES OFF THE FLOOR. C. HARDWARE FOR STORAGE FACILITIES SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. GENERAL ALL WORK TO BE DONE IN ACCORDANCE WITH THE LOCAL BUILDING CODE, AND REGULATIONS OF ALL OTHER AGENCIES HAVING JURISDICTION. STRUCTURAL A. CONTRACTOR TO PROVIDE ADEQUATE TEMPORARY BRACING AND SHORING WHEREVER ANY STRUCTURAL WORK IS INVOLVED. B. ALL DEMOLITION OPERATION, REPAIR OPERATIONS, AND ALTERATION OPERATIONS TO BE DONE IN ACCORDANCE WITH (APPLICABLE BUILDING CODE) MEANS OF EGRESS ALL EXISTING MEANS OF EGRESS FOR TENANTS OF THE BUILDING TO BE MAINTAINED CLEAR AND FREE OF ALL OBSTRUCTIONS, SUCH AS BUILDING MATERIALS, TOOLS, ETC. FIRE SAFETY A. ALL BUILDING MATERIALS STORED AT CONSTRUCTION AREA, AND/ OR GENERAL CONTRACTOR. B. ALL MATERIALS TO BE STORED IN AN ORDERLY FASHION. C. ALL FLAMMABLE MATERIALS TO BE KEPT AWAY FROM HEAT. D. ALL FLAMMABLE MATERIALS TO BE USED AND STORED IN AN ADEQUATELY VENTILATED SPACE. E. ALL ELECTRICAL POWER TO BE SHUT-OFF WHERE THERE ARE EXPOSED CONDUITS. F. ALL ELECTRICAL POWER IN THE CONSTRUCTION AREA TO BE SHUT OFF AFTER WORKING HOURS. G. CONTRACTOR, AT ALL TIMES, TO MAKE SURE THERE ARE NO LEAKS OF NATURAL GAS IN BUILDING, OR ANY FLAMMABLE GAS USED IN CONSTRUCTION. DUST CONTROL A. DEBRIS, DIRT, AND DUST TO BE KEPT TO A MINIMUM, AND BE CONFINED TO THE IMMEDIATE CONSTRUCTION AREA. B. CONTRACTOR TO ISOLATE CONSTRUCTION AREA FROM OCCUPIED BUILDING AREAS BY MEANS OF TEMPORARY PARTITIONS OR HEAVY WEIGHT DROP CLOTHES. C. DEBRIS, DIRT, AND DUST TO BE CLEANED UP AND CLEARED FROM BUILDING PERIODICALLY TO AVOID ANY EXCESSIVE ACCUMULATION. NOISE AFTER HOURS A. CONSTRUCTION OPERATIONS WILL BE CONFINED TO NORMAL WORKING HOURS: 8 A.M. TO 5 P.M., MONDAYS THROUGH FRIDAYS, EXCEPT LEGAL HOLIDAYS. B. CONTRACTOR TO OBTAIN PERMITS AND THE WRITTEN CONSENT OF ALL PARTIES AFFECTED BY HIS WORKING DURING OTHER THAN REGULAR HOURS. COORDINATE WITH MALL MANAGEMENT/LANDLORD'S REPRESENTATIVE. X X X REVISION TAG X KEYNOTE TAG ROOM NAME RM # AFF FINISH CEILING TAG ELEVATION TAG ROOM TAG A. FIELD CONDITIONS CONTRACTOR SHALL VERIFY ALL CONDITIONS AS WELL AS ALL DIMENSIONS AND CONDITIONS INDICATED IN THE DRAWINGS, PRIOR TO ACTUAL CONSTRUCTION. ANY VARIATION FROM CONDITIONS INDICATED IN THE DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND OWNERS REPRESENTATIVE PRIOR TO COMMENCING WORK. B. COORDINATION OF WORK THE CHARACTER AND SCOPE OF THE WORK ARE ILLUSTRATED BY THE WORKING DRAWINGS. CONTRACTOR SHALL CAREFULLY EXAMINE ALL THE DRAWINGS AND BE RESPONSIBLE FOR THE PROPER INSTALLATION OF HIS WORK AND PROPER CONSIDERATION FOR THE WORK OF OTHERS AND EXISTING BUILDING CONSTRUCTION. DO NOT PLACE DUCTS, PIPING, CONDUIT OR ANY OBSTRUCTION SO AS TO IMPAIR REQUIRED CEILING HEIGHTS AND CLEARANCE FOR LIGHTING FIXTURES, ETC. CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF EXISTING ADJACENT TENANT(S) AND BUILDING FACILITIES. CONTRACTOR TO COORDINATE WITH LANDLORD AND OBTAIN AND FOLLOW BUILDING RULES AND REGULATIONS FOR CONSTRUCTION. C. BUILDING CODES AND REGULATIONS ALL WORK SHALL CONFORM TO ALL CODES AND REGULATIONS. CONTRACTOR SHALL FILE, PAY FOR, AND OBTAIN ALL REQUIRED PERMITS TO PERFORM THE WORK. CONTRACTOR SHALL OBTAIN ALL REQUIRED APPROVALS FROM GOVERNMENTAL AGENCIES INVOLVED PRIOR TO FINAL PAYMENT. APPROVALS TO OCCUPY THE SPACE BY LOCAL BUILDING OFFICIALS SHALL BE OBTAINED. D. INSURANCE 1. CONTRACTOR SHALL SECURE, PAY FOR, AND MAINTAIN DURING CONSTRUCTION FIXTURING WORK WITHIN LEASED PREMISES, ALL OF THE INSURANCE POLICIES REQUIRED AND IN THE AMOUNTS AS SET FORTH HEREIN. CONTRACTOR SHALL NOT COMMENCE ANY WORK UNTIL ALL REQUIRED INSURANCE HAS BEEN OBTAINED AND CERTIFICATES OF SUCH INSURANCE HAVE BEEN DELIVERED TO THE LANDLORD AND TENANT. LANDLORD AND H & M, HENNES & MAURITZ, LP, 110 5TH AVENUE, NEW YORK, NY 10011 MUST BE NAMED AS "ADDITIONAL INSURED". THIS WORDING NEEDS TO BE INCLUDED: THE FOLLOWING PARTIES AS ADDITIONAL INSURED: ALL PARTIES INCLUDING H & M, HENNES & MAURITZ, LP, 110 5TH AVENUE, NEW YORK, NY 10011 RESPECTED OFFICERS, AGENTS, EMPLOYEES AND AFFILIATES OF ALL OF THE AFOREMENTIONED PARTIES. AN AFFILIATE SHALL BE DEFINED AS ANY CORPORATE ENTITY WHICH IS A PARENT OR SUBSIDIARY OF ANY OF THE AFOREMENTIONED PARTIES, OR WHICH HAS THE SAME PARENT CORPORATION AS ANY OF THE AFOREMENTIONED PARTIES. CERTIFICATES OF INSURANCE SHALL COVER ALL WORK PERFORMED BY G.C. AND EACH OF HIS SUBCONTRACTORS AND ALL MAJOR SUPPLIERS. 2. GENERAL CONTRACTOR'S AND SUBCONTRACTORS' REQUIRED MINIMUM COVERAGE AND LIMITS OF LIABILITY: A. WORKMEN'S COMPENSATION INSURANCE - IN ACCORDANCE WITH THE GOVERNING LAWS WITH A LIMIT OF NOT LESS THAN $1,000,000. AND ANY INSURANCE REQUIRED BY ANY EMPLOYEE BENEFITS ACTS, ETC. AS WILL PROTECT THE CONTRACTOR AND SUBCONTRACTORS FROM ANY AND ALL LIABILITY. B. CONTRACTOR SHALL PAY FOR AND FURNISH TO TENANT AND LANDLORD, CERTIFICATES OF INSURANCE WHICH WILL PROTECT SAID CONTRACTOR FROM CLAIMS (i) UNDER WORKMAN'S COMPENSATION ACTS AND OTHER EMPLOYEE BENEFIT ACTS, WITH LIMITS OF NOT LESS THAN $5,000,000.; (ii) FOR DAMAGES BECAUSE OF BODILY INJURY, (INCLUDING DEATH) TO HIS EMPLOYEES AND ALL OTHERS, WITH THE LIMITS OF $5,000,000 PER PERSON AND $5,000,000. PER OCCURRENCE; AND (iii) FOR DAMAGES TO PROPERTY WITH LIMITS OF $5,000,000. WHICH ARISE OUT OF OR RESULT FROM THE CONTRACTOR'S WORK UNDER THIS CONTRACT WHETHER SUCH WORK (INCLUDING OPERATION OF MOTOR VEHICLES) BE BY HIMSELF OR OTHERS DIRECTLY OR INDIRECTLY EMPLOYED BY EITHER; AND BUILDERS RISK INSURANCE IN THE FULL AMOUNT OF THE CONTRACT SUM. EXCESS / UMBRELLA LIABILITY $10,000,000 EACH OCCURRENCE AND $10,000,000 AGGREGATE. C. CONTRACTOR SHALL ALSO PROVIDE GENERAL LIABILITY INSURANCE AS FOLLOWS - $1,000,000 EACH OCCURRENCE AND $2,000,000 GENERAL AGGREGATE. 3. INDEMNIFICATION - TO THE FULLEST EXTENT PERMITTED BY LAW, THE CONTRACTOR SHALL INDEMNIFY AND HOLD HARMLESS THE LANDLORD, TENANT, AND THE ARCHITECT AND THEIR AGENTS AND EMPLOYEES FROM AND AGAINST ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES, INCLUDING BUT NOT LIMITED TO ATTORNEY'S FEES ARISING OUT OF OR RESULTING FROM THE PERFORMANCE OF THE WORK, PROVIDED THAT ANY SUCH CLAIM, DAMAGE, LOSS, OR EXPENSE (1) IS ATTRIBUTABLE TO BODILY INJURY, SICKNESS, DISEASE, OR DEATH, OR TO INJURY OR TO DESTRUCTION OF TANGIBLE PROPERTY (OTHER THAN THE WORK ITSELF) INCLUDING THE LOSS OF USE RESULTING THEREFROM, AND (2) IS CAUSED IN WHOLE OR IN PART BY A NEGLIGENT ACT OR OMISSION OF THE CONTRACTOR, ANY SUBCONTRACTORS, ANYONE DIRECTLY OR INDIRECTLY EMPLOYED BY ANY OF THEM MAY BE LIABLE, REGARDLESS OF WHETHER OR NOT IT IS CAUSED IN PART BY A PARTY INDEMNIFIED HEREUNDER. E. LIEN WAIVERS AND SWORN AFFIDAVITS CONTRACTOR SHALL FURNISH WITHIN 30 DAYS AFTER COMPLETION, FINAL WAIVERS OF LIEN FOR ALL WORK PERFORMED AS WELL AS ALL SUBCONTRACTORS AND MAJOR SUPPLIERS F. CERTIFICATE OF OCCUPANCY CONTRACTOR WILL PROVIDE TENANT AND LANDLORD WITH A COPY OF THE CERTIFICATE OF OCCUPANCY. G. QUALITY STANDARDS ALL SUCH WORK SHALL BE PERFORMED IN A FIRST CLASS WORKMANLIKE MANNER AND SHALL BE IN GOOD AND USEABLE CONDITION AT THE DATE OF COMPLETION THEREOF. CONTRACTOR SHALL GUARANTEE ALL WORK PERFORMED TO BE FREE FROM ANY AND ALL DEFECTS IN WORKMANSHIP AND MATERIALS FOR ONE (1) YEAR FROM THE DATE ALL CONSTRUCTION PUNCH LIST ITEMS HAVE BEEN COMPLETED AND ACCEPTANCE HAS BEEN CONFIRMED IN WRITING BY THE TENANT REPRESENTATIVE. CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPLACEMENT OR REPAIR WITHOUT ANY ADDITIONAL CHARGE FOR ANY AND ALL WORK DONE OR FURNISHED WHICH SHALL BECOME DEFECTIVE WITHIN THIS ONE (1) YEAR PERIOD. THE CORRECTION OF SUCH WORK SHALL INCLUDE, WITHOUT ADDITIONAL CHARGE, ALL EXPENSES AND DAMAGES IN CONNECTION WITH SUCH REMOVAL, REPLACEMENT, OR REPAIR OF ANY PART OF THE WORK WHICH MAY BE DAMAGED OR DISTURBED THEREBY. ALL WARRANTIES OR GUARANTEES AS TO MATERIALS OR WORKMANSHIP ON OR WITH RESPECT TO TENANT'S WORK SHALL BE CONTAINED IN THE CONTRACT OR SUBCONTRACT WHICH SHALL BE SO WRITTEN THAT SUCH GUARANTEES OR WARRANTEES SHALL INSURE TO THE BENEFIT OF BOTH LANDLORD AND TENANT, AS THEIR RESPECTIVE INTEREST APPEAR AND CAN BE DIRECTLY ENFORCED BY EITHER. H. RUBBER WHEEL CARTS CONTRACTOR'S CARTS, EQUIPMENT BOXES, ETC., MUST BE EQUIPPED WITH RUBBER WHEELS. J. FIRE EXTINGUISHERS EXISTING LOCATIONS TO BE MAINTAINED, IF IT ACCOMMODATES NEW LAYOUT WHERE APPLICABLE. CONTRACTOR TO VERIFY REQUIRED NUMBER AND LOCATION OF ANY ADDITIONAL EXTINGUISHERS REQUIRED BY FIRE DEPARTMENT AND FURNISH AND INSTALL SAME. INSTALL AFTER FIXTURING. K. RESPONSIBILITY FOR MATERIALS ON SITE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL MATERIALS SHIPPED TO THE JOB SITE INCLUDING MATERIALS FURNISHED BY OTHERS. COST OF ALL MISSING MATERIALS WILL BE DEDUCTED FROM THE CONTRACT PRICE AND FINAL PAYMENT. CONTRACTOR TO CHECK ALL INVOICES AT TIME SHIPMENT IS RECEIVED AND NOTIFY TENANT REPRESENTATIVE OF ANY DISCREPANCIES, DAMAGED OR MISSING ITEMS WITHIN 48 HOURS OF DELIVERY. L. RUBBISH REMOVAL CONTRACTOR SHALL BE RESPONSIBLE FOR DAILY REMOVAL FROM THE PROJECT, ALL TRASH, RUBBISH AND SURPLUS MATERIALS RESULTING FROM CONSTRUCTION, FIXTURING AND MERCHANDISING OF THE DEMISED PREMISES. COORDINATE REMOVAL OF DEBRIS WITH SHOPPING CENTER MGMT. GENERAL NOTES CONSTRUCTION LEASE LINE FIRE RATED OR RETARDANT DESIGN CONTROL LINE CERAMIC TILE MATERIAL GYPSUM WALLBOARD FINISH OR FINISHED EACH CONTRACTOR CEILING CEILING HEIGHT BACK OF HOUSE L.L. MATL. GYP. BD. F.R. FIN. = = = = = CONTR. C.T. D.C.L. EA. CONST. C.H. B.O.H. CLG. = = = = = = = FIBERGLASS REINFORCED PANELSFRP = HOLLOW METALHM = GENERAL CONTRACTORG.C. = = BOTTOM OFB.O. = EXISTING(E)/EXIST./EX'G. = AUTHORITY HAVING JURISDICTIONAHJ = ACOUSTICAL CEILING TILEACT = FIRE RETARDANT TREATEDFRT = CENTER LINEC =L EQUIPMENTEQUIP. = HOURHR. = MAXIMUMMAX. = COLUMNCOL. = ALUMINUMAL OR ALUM. = MIN. MINIMUM= LOCAL LAWS (HANDICAPPED ACCESS) TENANT'S SAFETY PLAN ABBREVIATIONS AND DEFINITIONS SYMBOLS DOOR TAG DETAIL NUMBER AREA DETAILED SHEET LOCATOR ACCESSIBILITY CLEARANCES NOTE: * = 48 IN (1220 MM) MINIMUM IF DOOR HAS BOTH A CLOSER. NOTE: * = 48 IN (1220 MM) MINIMUM IF DOOR HAS BOTH A LATCH AND CLOSER. 42"MIN 1065mm 54" MIN 1370 mm NOTE: * = 54 IN (1370 MM) MINIMUM IF DOOR HAS CLOSER. 48"MIN 1220mm PUSH SIDE 24" MIN 610 mm 42"MIN 1065mm PUSH SIDE PULL SIDE NOTE: X = 36 IN (915 MM) MINIMUM IF Y = 60 IN (1525 MM); X = 42 IN (1065 MM) MINIMUM IF Y = 54 IN (1370 MM). PUSH SIDE Y X PULL SIDE PULL SIDE ANSI FIG.404.2.4.1 MANEUVERING CLEARANCE AT SWINGING DOORS (A) FRONT APPROACH, PULL SIDE (B) FRONT APPROACH, PUSH SIDE (C) HINGE APPROACH, PULL SIDE (D) HINGE APPROACH, PUSH SIDE (E) LATCH APPROACH, PULL SIDE (F) LATCH APPROACH, PUSH SIDE 12 IN (305 MM) MIN WHERE LATCH + CLOSER ARE PROVIDED LOUNGE SINK 30" MIN 760 815710 28"32"36" 915 (A) BEFORE REMOVAL OF CABINETS AND BASE (B) CABINETS AND BASE REMOVED AND HEIGHT ALTERNATIVES 22" MIN 560 12 IN (305 MM) MIN WHERE LATCH + CLOSER ARE PROVIDED 60"MIN 1525mm 18" MIN 445 mm 48"MIN 1220mm 24" MIN 610 mm TEMPORARY UTILITIES PRE-CONSTRUCTION ARCHITECTURAL MECHANICAL ELECTRICAL PLUMBING FIRE PROTECTION POST CONSTRUCTION NOTE 1 ELECTRICAL SERVICE AND CONNECTIONS BY GENERAL CONTRACTOR NOTE 4 SEE DWGS. FOR ADDT'L. REQ'TS. FOR EX'G. DEMISING PARTITIONS TO BE COMPLETED BY GC. GC TO V.I.F. BEFORE BID NOTE 2 GENERAL CONTRACTOR TO PURCHASE SCHEDULED FIXTURES FROM TENANTS VENDOR NOTE 3 SEE ACCESSORY SCHEDULE ON DRAWINGS NOTE 6 INCLUDING MODIFICATION OF ANY EXISTING HEAD LOCATIONS NOTE 5 INSTALLATION TO INCLUDE, UNLOADING, UNPACKING, ASSEMBLY AS REQ'D. AND PLACEMENT AS DIRECTED BY TENANT CLARIFICATION/ REMARKS TENANT TEN.VENDOR TENANTG.C. TENANT LANDLORD SEE DWGS. FOR NOTES SEE NOTE 5 SEE NOTE 5 SEE NOTE 7 REFER TO RCP SHEETS FOR MORE INFO. SEE NOTES 1 & 5, CONDUIT & PULL STRING BY G.C., AS NOTED IN ELECTRICAL SHTS. REFER TO ELEC. SHTS. FOR MORE INFO. SEE NOTE 5 SEE NOTE 5 SEE NOTE 5 & HARDWARE SCHEDULE SEE NOTE 5, G.C. TO PROVIDE BLK'G. NOTE 7 INCLUDING BUT NOT LIMITED TO POS DATA, AND COMMUNICATIONS SAW CUTTING, CORING, CHANNELING OF EXISTING CONCRETE DEMOLITION WORK IN LEASED AREA CONCRETE FLOOR SLAB PREPARATION OF FLOOR SLAB FOR NEW FINISHES (INCL. LEVELING & PATCHING AS REQ'D.) CONTROL AND EXPANSION JOINTS IN CEILING, WALLS AND FLOORS RATED DEMISING PARTITION GYPSUM BOARD RATED DEMISING PARTITION STUDS PARTITIONS WITHIN LEASED SPACE METAL STRAPPING, BLOCKING AND LEDGERS ACOUSTIC AND THERMAL INSULATION WALL FINISHES INCLUDING BUT NOT LIMITED TO PAINT RECESSED AND WALL MOUNTED STANDARDS, PANELS AND ASSOCIATED INSTALLATION COMPONENTS BACK OF HOUSE MILLWORK AND ASSOCIATED SHOP DRAWINGS BACK OF HOUSE COLORED CORNER GUARDS & WALL PROTECTION (FRP) SALES AREA / FITTING ROOM AREA(S) ALUMINUM WALL BASE BACK OF HOUSE VINYL WALL BASE HOLLOW METAL DOORS, FRAMES, AND DOOR HARDWARE FITTING ROOM DOORS, FRAMES, CURTAINS, CURTAIN RODS, AND HARDWARE FITTING ROOM COMPARTMENT ACCESSORIES ACOUSTIC TILE CEILING SYSTEM GYP BOARD CEILINGS, GYP BOARD SOFFITS, AND SUPPORT FRAMING & ACCESS DOORS/PANELS MIRRORS - SALES FLOOR AS INDICATED MIRRORS FITTING ROOM COMPARTMENTS AS INDICATED & SPECIAL MIRRORS CASHWRAP AND FREE STANDING FLOOR FIXTURES COUNTERS, CABINETS, SHELVING AND MISC. CASEWORK AT BACK OF HOUSE FLOOR SAFE AT OFFICE FLOOR, ROOF PENETRATIONS AND PATCHING HVAC DUCTWORK AND SUPPORTING FRAMING HVAC DIFFUSERS AND GRILLES SMOKE DETECTORS DAMPERS EXHAUST FANS CONTROLS AND CONNECTIONS OUTSIDE AIR INTAKE TESTING AND BALANCING ALL EQUIPMENT ON TENANT RISER DIAGRAM DATA AND COMMUNICATIONS WIRING LIGHT FIXTURES -SALES AND DISPLAY AREAS LIGHT FIXTURES - BACK OF HOUSE EMERGENCY LIGHTS AND SIDE LIT EXIT SIGNS LAMPS ON SALES FLOOR LAMPS AND INSTALLATION OF TRACK FIXTURES ILLUMINATED SIGNAGE AT STOREFRONT 2" CONDUIT w/ PULL STRING FROM LL'S PHONE CLOSET TO TENANT LAN. ROOM AT 13'-6" A.F.F. MIN. 25 PAIR CAT5E CABLE FROM PHONE CLOSET TO LAN ROOM SECURITY SYSTEM DATA AND TELEPHONE SERVICE TO PREMISES DATA AND TELEPHONE EQUIPMENT BELL AT EMPLOYEE ENTRANCE AUDIO/ VISUAL SYSTEM COMPONENTS SPEAKERS SPEAKER LOW VOLTAGE WIRING SANITARY WASTE, DOMESTIC SUPPLY AND VENT PIPES TO PREMISES WATER METER SANITARY WASTE, DOMESTIC SUPPLY AND VENT PIPES WITHIN PREMISES FIXTURES, EQUIPMENT, & ACCESSORIES FLOOR DRAINS AND WATERPROOF MEMBRANE SPRINKLER MAIN AND DISTRIBUTION BRANCHES TO PREMISES AT 13-6" A.F.F., MIN. SPRINKLER BRANCHES DROPS AND HEADS FIRE ALARM SYSTEM FIRE EXTINGUISHERS (COORDINATE LOCATIONS W/ FIRE MARSHAL & TENANT REP.) SMOKE DETECTORS FINAL CLEAN UP AND MAKE READY FOR OCCUPANCY CERTIFICATE OF OCCUPANCY SEE NOTES 1 & 5 FIRE-SAFING AND FIRE-PROOFING FURNISHED BY INSTALLED BY RESPONSIBILITY SCHEDULE NOTES X-RAY SLAB AS REQUIRED IF REQ'D. - USE LL CONTRACTOR AS REQ'D. HVAC UNIT(S) & STRUCTURAL SUPPORT (IF REQ'D.) SMOKE EVACUATION SYSTEM (WHERE APPLICABLE) ELECTRICAL SERVICE TO PREMISES AT 13'-6" A.F.F. MINIMUM CONDUIT FOR COPPER FEED FROM LL'S SWITCH GEAR TO TENANT ELEC. ROOM COPPER FEED FROM LL'S SWITCH GEAR TO TENANTS ELECTRICAL ROOM FUSIBLE DISCONNECT AND LANDLORD'S SWITCH GEAR LAN CABINET ALL PATCH PANELS AND WIRE MANAGEMENT CONSECUTIVELY LABELED CONTINUITY TEST REPORT FINISHED TO OWNER METER TENANT MAIN DISTRIBUTION "MDP" (INCLUDING DISPOSAL OF ALL ASSOCIATED CRATING & DEBRIS) DATA AND COMMUNICATIONS CONDUIT SEE CONSTRUCTION SHTS. SEE MECH. DWGS. AS REQUIRED G.C. TO COORDINATE, SEE A-600 SERIES SHTS. SEE MECH. DWGS. FIRE RATED PAINTED PLYWOOD FOR TECHNOLOGY USE LOW VOLTAGE SLEEVES AND FIRE STOPPING PULL STRING IN CONDUITS AS NOTED IN ELECTRICAL DRAWINGS AS NOTED IN ELECTRICAL SHTS. COMPLETED CONDUIT PATHWAY SYSTEM FROM UTILITY COMPANY/LL END BOX INTO TEN. SPACE COMPLETE TECHNOLOGY GROUNDING SYSTEM INCLUDING BUT NOT LTD. TO, GROUND CONDUCTOR, COPPER BUS BARS & ALL ASSOC. HDWR REQ'D TO COMPLETE GROUNDING SYSTEM. BONDING OF ALL TECH. EQUIPMENT TO GROUND SYSTEM FIELD QUALITY CONTROL (TESTING AND CERTIFICATION) ALL REQUIRED DATA HARDWARE IDENTIFICATION PRODUCTS ADMIN OFFICE CABINETS, SHELVING AND MISC. CASEWORK SEE NOTE 6 SECURITY SYSTEM CONDUIT AS NOTED IN ELECTRICAL DRAWINGS NEW OPENING IN UPPER LEVEL FLOOR SLAB FOR STAIRS AND ELEVATOR STRUCTURAL WORK STAIR FRAMING, ELEVATOR SHAFT, HOIST BEAM & FRAMING FOR LOWER LEVEL EXTENSION ELEVATOR (CAB, MACHINES AND RELATED EQUIPMENTS) VERTICAL TRANSPORTATION ELEVATOR TRANSPORTATION AND PERMITS STOREFRONT CONSTRUCTION BARRICADE (TAPED, SANDED, AND PAINTED), FITTED WITH DOUBLE DOORS FLOOR LEVELING (1/4" OVER 10'-0") SPECIAL INSPECTIONS N/A INTERIOR BARRICADE PANELS & STANDARDS H&M GRAPHICS AND WALLPAPER CUBE DOOR SECURITY SYSTEM (DOOR JAMB) ALL REQUIRED BLOCKING USE LL CONTRACTOR AS REQ'D. USE LL CONTRACTOR AS REQ'D. USE LL CONTRACTOR AS REQ'D. USE LL CONTRACTOR AS REQ'D., SEE FP SHTS. USE LL CONTRACTOR AS REQ'D. LANDLORD G.C. TO PATCH & REPAIR AS REQ'D. TO MAINTAIN RATING, SEE CONSTRUCTION SHTS. PROVIDE GYP. BD. WHEREVER NOT EXISTING ON TENANT'S SIDE ONLY & FIRE TAPE, CAULK, AND SEAL AS REQ'D TO ACHIEVE RATING AS NOTED. TEN.VENDOR TENANTG.C. NOT APPLICABLE NOT APPLICABLE STOREFRONT SUPPORT AND FRAMING NOT APPLICABLE NOT APPLICABLE CONTROL JTS. AS REQ'D. WHERE APPLICABLE SALES AREA / FITTING ROOM AREA(S) CERAMIC TILE FLOOR BACK OF HOUSE VCT FLOOR / CONCRETE MOTORIZED ROLLING GRILLE AT STOREFRONT ENTRANCE(S) STOREFRONT FRAMING AT PIERS, CLADDING, ALUM. STOREFRONT SYSTEM AND GLAZING SOLID CORE WOOD DOORS, FRAMES, AND DOOR HARDWARE SEE DOOR SCHEDULE ON SHT. A-800 SEE DOOR SCHEDULE ON SHT. A-800 STOCKROOM FIXTURES AND SHELVING ALL WD. BLOCKING SHALL BE FRT COORDINATE WITH LL'S REP. SEE MECH. DWGS. LL TO PROVIDE PER TENANT'S PLAN COORD. W/ LL'S REP. AS BUILT DRAWINGS, AIR BALANCE REPORT AND USER MANUALS SEE DOOR SCHEDULE ON SHT. A-800 SEE SHT. A-200 AND A-700 SERIES SEE PLUMBING DRAWINGS FOR MORE INFO. SEE STRUCTURAL DWGS. FOR MORE INFO. G.C. TO VERIFY LINEAR FOOTAGE ON DWGS. G.C. TO VERIFY LINEAR FOOTAGE ON DWGS. SEE A-600 SHTS. & DOOR SCHEDULE ON SHT. A-800 SEE A-600 SHTS. FOR MORE INFO. SEE CONSTRUCTION SHTS. FOR MORE INFO. F/E CABINETS BY GC NOT APPLICABLE REFER TO ELEC. SHTS. FOR MORE INFO. REFER TO ELEC. SHTS. FOR MORE INFO. REFER TO ELEC. SHTS. FOR MORE INFO. BARRICADE REMOVAL TOP OF SLAB TO BE 1/2" LOWER THAN EXISTING FLOORING, PER LEASE.G.C. TO CONTRACT PSI TO PERFORM LEVELING TEST PRIOR TO FLOOR INSTALLATION SEE PLUMBING DRAWINGS FOR MORE INFO. SPRINKLER SYSTEM SHUTDOWNS AND FIRE ALARM TIE-INS SHALL BE AT TENANT'S REASONABLE EXPENSE, NOT TO EXCEED $250.00 PER SHUTDOWN. NOTWITHSTANDING THE FOREGOING, THE FIRST SHUTDOWN IS FREE. CONSTRUCTION TRASH AND DEBRIS ARE TO BE REMOVED AT TENANT'S CONTRACTOR EXPENSE. COORDINATE WITH LANDLORD'S WORK LETTER. IF REQUIRED H&M CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING FULL "AS-BUILT" CONSTRUCTION DOCUMENTS TO H&M PROJECT ARCHITECT IS DIRECTION UPON CONSTRUCTION COMPLETION AS A REQUIREMENT FOR PROJECT CLOSE-OUT PROJECT CLOSE OUT SHOULD OCCUR WITHIN 60-90 DAYS AFTER THE STORE OPENS. FINAL REQUISITION FOR PAYMENT WILL BE MADE TO THE CONTRACTOR WHEN ALL CLOSE OUT PAPERWORK IS IN A COMPLETE CLOSE OUT FILE TO INCLUDE; - SIGNED OFF PUNCH LISTS FROM H&M AND LANDLORD. - FINAL LIEN WAIVERS FROM G.C. AND ALL SUBCONTRACTORS. - AS BUILT DRAWINGS - AIR BALANCE REPORT BY INDEPENDENT AIR BALANCING COMPANY WHICH HAS BEEN REVIEWED AND APPROVED BY THE PROJECT MECHANICAL ENGINEER. - CERTIFICATE OF OCCUPANCY AND ALL INSPECTION SIGN OFF CARDS. - ALL EQUIPMENT OPERATION AND MAINTENANCE MANUALS. - SWORN STATEMENT OF CONTRACTORS COSTS FORM - LIST OF ALL SUBCONTRACTORS WITH CONTACT NAMES AND PHONE NUMBERS - CHANGE ORDER ANALYSIS FORM - CONTRACTORS CERTIFICATE OF INSURANCE PROJECT CLOSE OUT AS BUILT DRAWINGS LIST OF SUBMITTALS/SHOP DRAWINGS 1. GENERAL CONTRACTOR AND SUB CONTRACTOR TO PROVIDE SUBMITTALS/ SHOP DWGS. FOR REVIEW & APPROVALS TO ARCHITECT, TENANT, LANDLORD, DEPT. OF BLDG. AND ALL REQUIRED AUTHORITIES AND AGENCIES. REFER TO S.M.E.P. DOCUMENTS FOR SPECIFIC SHOP DRAWINGS REQUIRED FOR THIS PROJECT. SIGNAGE QUARRYCAST H.V.A.C. UNITS & CONTROLS INTERIOR WOODWORK (B.O.H. MILLWORK) DUCT LAYOUT & CONNECTIONS STRUCTURAL STEEL FRAMING FIRE ALARM STEEL DOORS/ FRAMES SPRINKLER ROLL UP GRILLES ACCESS PANEL GLAZING STOREFRONT ACOUSTICAL CEILING TILE & GRID ESCALATORS (WHERE APPLICABLE) TOILET COMPARTMENTS ELEVATORS (WHERE APPLICABLE) STEEL LOCKERS DOOR HARDWARE TOILET ACCESSORIES SMOKE BAFFLE CONCRETE MIX HANDRAILS/ GUARDRAILS REINFORCING BAR STAIR CALC. FOR PILE DESIGN BRAKE METAL PLUMBING FIXTURES RECEPTACLES LIGHTING FIXTURES ELECTRICAL DISTRIBUTION DISCONNECT/ SWITCHES DIFFUSERS/ GRILLES 2. G.C. TO SUBMIT CEILING COORDINATION PLAN w/ LOCATION OF ALL DEVICES (LIGHTING, INT. SIGNAGE, LIT. NAVIGATION, DIFFUSERS, ACCESS PANELS, SPRINKLER HEADS, ETC.) FOR APPROVALS NOT LIMITED TO THIS LIST RESPONSIBILITY SCHEDULE UNLESS OTHERWISE NOTED VINYL COMPOSITION TILE V.I.F. w/ V.C.T. U.O.N. T.O. = = = = = S.S. TEN. STD. O.C. R.U.G. = = = = = VERIFY IN FIELD WITH TOP OF STAINLESS STEEL ON CENTER ROLL UP GRILLE STANDARD TENANT N.T.S. MIR. = MIRROR OR MIRRORED NOT TO SCALE REF = REFERENCE SOLID CORE WOOD DOORSC WD = = THK. = THICK MTL. METAL= PLYWD. PLYWOOD= SIMILARSIM. = SHEETSHT. = REQ'D. = REQUIRED REQ'TS. = REQUIREMENTS THICKTHK. = UNDERSIDEU.S. = OPP. = OPPOSITE N.I.C. NOT IN CONTRACT= P.C. POWDER COAT= SPECIAL MIRRORSM. = F.E. MPSS TBS FA PVM = = = = = NOTE 8 VERIFY PER PROJECT. COORDINATE RESPONSIBILITY WITH " L.L.'S WORK LETTER". FIRE EXTINGUISHERS TO BE SCHEDULED PEOPLE VIEW MONITOR MIRROR POLISHED STAINLESS STEEL FIRE ALARM INTERCOM (2) SEPARATE SOURCES. GC TO PROVIDE AN ADDITIONAL 1" CONDUIT FURNISHED & INSTALLEDF & I = X FIXTURE TAG HANDICAPPEDH.C. = ACCESS PANELS X X X X X FILE CABINETFC = SAFETY CABINETSC = 3-TIER OR 6-TIER LOCKERLKR = STOREFRONT SIGNAGE SALES AREA ALUMINUM CORNER GUARDS SEE FIXTURE SHTS. SALES AREA SIGNAGE LIGHTBOXES SEE A-600 SHTS. X - X X X DISCIPLINE DESIGNATOR (ARCH.,PLUMB., ELEC., ETC.) SHEET TYPE (CONSTRUCTION DESCRIPTION) SEQUENCE NUMBERS GENERAL OR FLOOR LEVEL (CELLAR, FIRST FLOOR SECOND FLOOR, ETC.) SEQUENCE NUMBERS (NUMBER OF DRAWINGS IN SEQUENCE) *NOTES: ANY DRAWING THAT IS CHANGED AFTER THE FIRST ISSUE WILL HAVE A DELTA WITH SEQUENCE # ( ) AND 'REVISION SEQUENCE' NUMBER WILL MATCH DELTA #. DELTA NUMBERS WILL SHOW ON APPLICABLE REVISED SHEETS IN TITLE BLOCK COLUMN. IF A DRAWING IS NOT REVISED, BUT PUBLISHED WITH NEW REVISED SHEET(S), THE REVISION NUMBER WILL NOT CHANGE ON THAT SHEET EVEN THOUGH THE NEW REV APPEARS ON THE TITLE BLOCK COLUMN AT BOTTOM. SHEET NUMBER REVISION: SHEET TITLE: SPACE NO.: ARCH PROJECT NO.: SCALE: DRAWN BY: REV. NO: SHEET NO: PRODUCT SEASON: 2018 US667-BLUE BRANSONLANDING BUILDING1000 SPACENOS.1003-1013 100BRANSONLANDINGBLVD BRANSON,MOZIP65616 AS NOTED 2018 2187-17 ISSUE DATE: 1003-1013 1 11.06.17 PROTOTYPE UPDATES D.O.B. NO: 12.18.17 CLIENT/LANDLORD REVIEW 4 6 1 F R O M R O A D PARAMUS, NJ 07652 973.253.9393 TEL 973.253.9390 FAX WWW.SARGARCH.COM VP A-010 GENERAL NOTES AND RESPONSIBILITY SCHEDULE
  • 40. SERVICE AREA PLACEFOR MANNEQUINS PLACE FOR MANNEQUINS 3-TIER LOCKER 3-TIER LOCKER 3-TIER LOCKER 3-TIER LOCKER 3-TIER LOCKER 3-TIER LOCKER 3-TIER LOCKER 3-TIER LOCKER 3-TIER LOCKER 3-TIER LOCKER 3-TIER LOCKER 3-TIER LOCKER 3-TIER LOCKER 3-TIER LOCKER 3-TIER LOCKER 3-TIER LOCKER 48"X30" CLR. 30"x48" RECYCLE VINYL ON WALL SAMPLE WALL 42" ROUND F BL.ASH M W.ASH L WO WOEND Girl134-170 WOSTARTWOWOWOWOENDWOSTARTWOWOWOWOEND WOSTART WO WO WO WO WO WO WO WO WO WO WO WO WO WO WO END WOSTARTWOWOWOWO WO STARTWOWOWOWOWOWOWOEND F WO WO WO WO WOSTART WO WO WO WO WO WO WO END SE S E SE S E SESE SE SE SE W (LADIES) SALES AREA 001 (LAD. DIV) SALES AREA 001 (KIDS) SALES AREA 001 ROOM #1 STOCK 017 LOUNGE 014 WINDOW #4 POSTER 008 WINDOW #1 POSTER 002 WINDOW OPEN 003 WINDOW #2 POSTER 004 WINDOW DISPLAY 005 ENTRY 006 WINDOW #3 POSTER 007 ROOM ADMIN 009 MTG. RM. SECURITY 010 HALLWAY 012 CLOSET JANITOR'S 011 TOILET RM. WOMEN'S H/C 013 TOILET RM. MEN'S H/C 015 ROOM LAN 016 ROOM ELECTRICAL 018 AREA #1 FITTING RM. 019 ROOM #2 STOCK 020 AREA #2 FITTIN RM. 021 ROOM #3 STOCK 022 WINDOW #5 POSTER 023 (MENS) SALES AREA 001 NIGHTBOX REMOTE 024 EX2 EX1 EX1 EX1 EX1 EX2 EX1 EX1 EX1EX1 EX1 EX1 EX1 EX1 EX1 EX2 EX2 EX2 EX2 F.E.2 F.E.2F.E.2 F.E.2 F.E.2 F.E.1 F.E.1 F.E.1 F.E.3 F.E.3 F.E.1 F.E.1 EXTERIOR F.E.1 F.E.1 F.E.2 EX1 F.E.2 EX2 WO STARTWOWOWOWOWOWOWOEND WO WO STARTWOWOWOEND WOSTART WO WO WO END WO WO WO A B C D E C.3 12345678910 EXTERIOR EXTERIOR EXTERIOR EXTERIOR MALL SERVICE CORRIDOR MALL SERVICE CORRIDOR EX1 EX1 EX1 DIAGONAL DISTANCE OF AREA SERVED = 241'-11" WALL MTD. FIRE EXTINGUISHER AND ALL REQUIRED MOUNTING EQUIPMENT, SUPPLIED AND INSTALLED BY G.C. G.C. TO PROVIDE F.R. WOOD BLOCKING AS REQ'D. FOR PROPER MOUNTING NOTE: G.C. TO VERIFY AND COORDINATE ALL LOCATIONS MOUNTING HEIGHTS AND REQUIREMENTS OF EMERGENCY EQUIPMENT WITH STATE AND LOCAL CODES. 48"TOEXTINGUISHER HANDLE(MAX.) WALL MOUNTED FIRE EXTINGUISHER (F.E.1 & F.E.3) RECHARGEABLE EMERGENCY FLASHLIGHT 44"TOCENTERLINE OFCHARGER&RECEPTACLE 60"MIN.TOBOTTOM OFSIGN EMERGENCY EVACUATION MAP LEGEND EMERGENCY EVACUATION MAP SURFACE MOUNTED EMERGENCY FLASHLIGHT AND WALL CHARGER EQUIPMENT, FURNISHED AND INSTALLED BY G.C. SURFACE MOUNTED EMERGENCY EVACUATION MAP WITH BLACK FRAME (SUPPLIED & INSTALLED BY G.C.) SIGN SIZE AND LETTERING TO MEET ALL STATE AND LOCAL CODE REQ'TS. LOCATE ABOVE FIRE EXTINGUISHER. BRUSHED STAINLESS STEEL WALL RECESSED FIRE EXTINGUISHER CABINET AND FIRE EXTINGUISHER INCLUDING ALL REQUIRED MOUNTING HANGER EQUIPMENT, SUPPLIED AND INSTALLED BY G.C. 48"TOCABINETHANDLE (HANDLECENTEREDONDOOR) RECESSED FIRE EXTINGUISHER CABINET (F.E.2) 6" HOLD OUTLINE OF SURFACE MOUNTED EMERGENCY EVACUATION MAP 1. MAINTAIN 3'-8" CLEAR PATH BETWEEN THE EXIT DOORS AT ALL TIMES. MAINTAIN 3'-0" CLEAR PATH BETWEEN FLOOR FIXTURES. 2. VERIFY EXIT SIGNS COORDINATE W/PATH OF EGRESS. REPORT ANY DISCREPANCIES TO ARCHITECT / ENGINEER PRIOR TO ROUGH- IN. 3. PER (CODE/SECTION) 'EXIT ACCESS TRAVEL DISTANCE', FOR OCCUPANCY 'M', TRAVEL DISTANCE NOT TO EXCEED 250 FEET FOR BUILDINGS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH CODE. 4. EXIT OR EXIT ACCESS DOORWAY ARRANGEMENT: WHERE ACCESS TO THREE OR MORE EXITS ARE REQ'D., AT LEAST TWO EXIT DOORS OR EXIT ACCESS DOORWAYS SHALL BE ARRANGED IN ACCORDANCE WITH THE PROVISIONS OF (CODE/SECTION) ·1/3 DIAG. DISTANCE OF AREA SERVED = 241'-11" / 3 = 80'-7 3/4" · DISTANCE BETWEEN 2 CLOSEST EXITS = 67'-4" · EXITS ARE IN COMPLIANCE * SYMBOL DESCRIPTION F.E.1 DENOTES 10 LBS. ABC 10-W. UNIT MOUNTED TO WALL W/ HANGER (NO CABINET). LOCATION OF FIRE EXTINGUISHERS ON PLAN ARE TENANT'S MINIMUM REQUIREMENTS. G.C. TO SUPPLY & INSTALL AND SHALL COORDINATE WITH TENANT'S REPRESENTATIVE AND LOCAL FIRE MARSHAL FOR ADDITIONAL REQUIRED LOCATIONS. F.E.2 DENOTES 10 LBS. UNIT IN BRUSHED SS RECESSED CABINET CENTERED ON RESPECTIVE WALL OR BETWEEN ADJACENT ELEMENTS. (SPEC # 128-EL-SG FULLY RECESSED TYPE FROM STRIKE FIRST CORP WWW.STRIKEFIRSTUSA.COM) LOCATION OF FIRE EXTINGUISHERS ON PLAN ARE TENANT'S MINIMUM REQUIREMENTS. G.C. TO PROVIDE & INSTALL AND SHALL COORDINATE WITH TENANT'S REPRESENTATIVE AND LOCAL FIRE MARSHAL FOR ADDITIONAL REQUIRED LOCATIONS. F.E.3 DENOTES 10 LBS. CO2-10BC. UNIT MOUNTED TO WALL W/ HANGER (NO CABINET) (IN LAN AND ELECTRICAL ROOM). (SPEC # CO2-10 FROM STRIKE FIRST CORP WWW.STRIKEFIRSTUSA.COM) LOCATION OF FIRE EXTINGUISHERS ON PLAN ARE TENANT'S MINIMUM REQUIREMENTS. G.C. TO SUPPLY & INSTALL AND SHALL COORDINATE WITH TENANT'S REPRESENTATIVE AND LOCAL FIRE MARSHAL FOR ADDITIONAL REQUIRED LOCATIONS. LOCATION OF EMERGENCY EVACUATION MAP. ARCHITECT TO PROVIDE MAP, G.C. TO MOUNT IN G.C. PROVIDED BLACK FRAME (REALSPACE SLIMLINE FRAME, 8-1/2"H X 11"W, CLEAR.) G.C. TO COORDINATE WITH TENANT'S REP. FOR LOCATIONS. MOUNTED ABOVE FIRE EXTINGUISHER (WHERE POSSIBLE). LOCATION OF EMERG. FLASHLIGHT DORCY 41-1032. SUPPLIED AND INSTALLED BY G.C. SEE DETAIL 3/A110 FOR MOUNTING HEIGHT. STOCK ROOM, ADMIN ROOM AND SEPARATE VISUAL ROOM TO RECEIVE FLASHLIGHTS. G.C. TO COORDINATE WITH TENANT'S REP. FOR ADDITIONAL LOCATIONS. 44" MIN. WIDE ACCESSIBLE MEANS OF EGRESS PATH EXIT POINT OF EGRESS PATH START POINT OF TRAVEL EXIT SIGNS, WALL / CELING MOUNTED (ARROW REPRESENTS DIRECTIONAL SIGN), TACTILE EXIT SIGNS TO BE PROVIDED BY G.C. AS REQUIRED PER LOCAL AHJ; SEE RCP SHTS. SAFE AREA DOOR SECURING DEVICE, BARRACUDA BY GLOABLINDUSTRIAL.COM. REFER TO DOOR SCHEDULE SHT. FOR MORE INFO. F.E. 2 F.E. 1 F.E. 3 1. G.C. TO INSTALL FIRE EXTINGUISHERS AS NOTED, BUT NOT LIMITED TO, THE FOLLOWING LOCATIONS (VERIFY W/ AHJ); · ALL OFFICES · ELECTRICAL ROOM · LAN ROOM · STOCKROOM · EMERGENCY EXIT PERIMETER DOOR · ALL CASHPOINTS · FITTING ROOM AREA · ALL DEPARTMENTS WITHOUT A CASHPOINT OR FITTING ROOM 2. FIRE EXTINGUISHERS IN LAN AND ELECTRICAL ROOM TO BE CO2 TYPE. 3. G.C. TO INSTALL TENANT PROVIDED EMERGENCY EVACUATION MAP INDICATING ALL EXITS AND EQUIPMENT (FIRE EXTINGUISHER, PULL STATION FIRE HOSE, ETC.) POSTED AS REQUIRED, ABOVE FIRE EXTINGUISHERS WHERE POSSIBLE. SEE PLAN FOR LOCATIONS. NOTE: REFER TO MANUF. INSTALLATION RECOMMENDATIONS FOR ATTACHMENT TO WALL. FIRE EXTINGUISHER CABINET BY 'STRIKE FIRST' OR APPROVED EQUAL. 8" REQ'D.WALL OPENING DEPTH OUTSIDE DIMENSIONS 11-1/2"x25" INSIDE DIMENSIONS 10-1/2" x 24" x 6" LOCATION FUNCTION OF SPACE AREA (S.F.) OCCUPANT LOAD (PERSONS) MULTIPLIER (PER CODE/ SECTION) EGRESS WIDTH REQUIRED (INCHES) EGRESS WIDTH PROVIDED (INCHES) SALES AREA (GRADE FLOOR) + DISPLAY/POSTER WINDOWS + OFFICE AREAS/SUPPORT + TOILET ROOMS: MERCANTILE 19544 19544 / 60 = 326 66.6" (44" MIN. FOR EGRESS PATH PROVIDED 36" MIN. FOR AISLE WIDTH PROVIDED, SEE SHEET A-000) 202" (FOR (2) EXITS FROM SALES AREA AND (1) EXITS FROM BACK OF HOUSE AREA)STOCK ROOM + VISUAL ROOM + NIGHT BOX STORAGE 2003 2003 / 300 = 7 TOTAL TWO EXITS REQ'D. PER (CODE) 21547 333 0.2 LOCATION TRAVEL PATH MAXIMUM TRAVEL DISTANCE SALES AREA EXIT ACCESS POINT A TO EXIT 1 POINT A TO EXIT 2 POINT B TO EXIT 2 POINT C TO EXIT 1 POINT C TO EXIT 2 POINT E TO EXIT 1 POINT D TO EXIT 1 POINT D TO EXIT 2 POINT E TO EXIT 2 164'-1" 242'-1" POINT F TO EXIT 1 POINT G TO EXIT 2 POINT H TO EXIT 1 POINT G TO EXIT 2 BOH / STOCK ROOM EXIT ACCESS 155'-11" 110'-3" 101'-7" 193'-8" 115'-2" 165'-7" 243'-7" 180'-10" 127'-1" 165'-6" 177'-9" 90'-7" 131'-11" POINT H TO EXIT 2 LOUNGE EXIT ACCESS 98'-9" POINT I TO EXIT 3 BOH EXIT ACCESS 51'-9" EGRESS PLAN LEGEND EXIT TRAVEL DISTANCE EGRESS NOTES FIRE EXTINGUISHER NOTES OCCUPANCY LOAD, EXITS, & EGRESS WIDTH CALCULATIONS PT. 'A' PT. 'F' PT. 'E' PT. 'G' PT. 'C' PT. 'J' PT. 'D' PT. 'I' PT. 'H' PT. 'B' * * * EXIT '1' EXIT '2' EXIT '3' POINT B TO EXIT 1 POINT J TO EXIT 1 POINT J TO EXIT 2 135'-1" 3'-8" TYP. 3'-8" TYP. 3'-8" TYP. 3'-8" TYP. 3'-8" TYP. 3'-8" TYP. 3'-8" TYP. 3'-8" TYP. 3'-8" TYP. 3'-8" TYP. 3'-8" TYP. 3'-8" TYP. 3'-8" TYP. 3'-8" TYP. 3'-8" TYP. 3'-8" TYP. 3'-8" TYP. 3'-8" TYP. 3'-8" TYP. 3'-8" TYP. * EXIT '4' PT. 'L' POINT L TO EXIT 4 REMOTE NIGHT BOX 30'-7" REVISION: SHEET TITLE: SPACE NO.: ARCH PROJECT NO.: SCALE: DRAWN BY: REV. NO: SHEET NO: PRODUCT SEASON: 2018 US667-BLUE BRANSONLANDING BUILDING1000 SPACENOS.1003-1013 100BRANSONLANDINGBLVD BRANSON,MOZIP65616 AS NOTED 2018 2187-17 ISSUE DATE: 1003-1013 D.O.B. NO: 12.18.17 CLIENT/LANDLORD REVIEW 4 6 1 F R O M R O A D PARAMUS, NJ 07652 973.253.9393 TEL 973.253.9390 FAX WWW.SARGARCH.COM EGRESS PLAN 1 SCALE: 1/8" = 1'-0" EGRESS PLAN (REMOTE NIGHTBOX) 2 SCALE: 1/8" = 1'-0" NORTH LIFE SAFETY EQUIPMENT MOUNTING HEIGHTS 3 SCALE: N.T.S. MH/VM A-110 EGRESS PLANS
  • 41. 3-TIER LOCKER 3-TIER LOCKER 3-TIER LOCKER 3-TIER LOCKER 3-TIER LOCKER 3-TIER LOCKER 3-TIER LOCKER 3-TIER LOCKER 3-TIER LOCKER 3-TIER LOCKER 3-TIER LOCKER 3-TIER LOCKER 3-TIER LOCKER 3-TIER LOCKER 3-TIER LOCKER 3-TIER LOCKER 48"X30" CLR. 30"x48" 42" ROUND F WO WOEND WOSTARTWOWOWOWOENDWOSTARTWOWOWOWOEND WOSTART WO WO WO WO WO WO WO WO WO WO WO WO WO WO WO END WOSTARTWOWOWOWO WO STARTWOWOWOWOWOWOWOEND WO WO WO WO WOSTART WO WO WO WO WO WO WO END SE S E SE S E SESE SE SE SE W (LADIES) SALES AREA 001 (LAD. DIV) SALES AREA 001 (KIDS) SALES AREA 001 ROOM #1 STOCK 017 LOUNGE 014 WINDOW #4 POSTER 008 WINDOW #1 POSTER 002 WINDOW OPEN 003 WINDOW #2 POSTER 004 WINDOW DISPLAY 005 ENTRY 006 WINDOW #3 POSTER 007 ROOM ADMIN 009 MTG. RM. SECURITY 010 HALLWAY 012 CLOSET JANITOR'S 011 TOILET RM. WOMEN'S H/C 013 TOILET RM. MEN'S H/C 015 ROOM LAN 016 ROOM ELECTRICAL 018 AREA #1 FITTING RM. 019 ROOM #2 STOCK 020 AREA #2 FITTIN RM. 021 ROOM #3 STOCK 022 WINDOW #5 POSTER 023 (MENS) SALES AREA 001 NIGHTBOX REMOTE 024 EXTERIOR WO STARTWOWOWOWOWOWOWOEND WO WO STARTWOWOWOEND WOSTART WO WO WO END WO WO WO A B C D E C.3 12345678910 EXTERIOR EXTERIOR EXTERIOR EXTERIOR MALL SERVICE CORRIDOR MALL SERVICE CORRIDOR SYMBOL DESCRIPTION PARTITION TYPE - REFER TO SHEET PARTITION TYPES SHEET DOOR NUMBER - REFER TO DOOR SCHEDULE SHEET ELEVATION TAG DETAIL TAG CONSTRUCTION TAG NOTE X X X XX X XX X SYMBOL DESCRIPTION EXISTING PARTITION TO REMAIN: PATCH & REPAIR AS REQ'D TO "LIKE NEW" CONDITION & MAINTAIN EXISTING RATING NEW NON-RATED PARTITION: REFER TO WALL TAG FOR PARTITION TYPE NEW RATED PARTITION (U#465): REFER TO CONSTRUCTION PLAN FOR PARTITION TYPE; FIRE SEAL TOP OF PARTITION & ALL PENETRATIONS TO MAINTAIN FIRE RATING & PROVIDE FRT PLYWOOD ON WALLS AS REQ'D NEW NON-RATED SECURITY PARTITION: REFER TO CONSTRUCTION PLAN FOR PARTITION TYPE; 5/8" TYPE 'X' GYP. BD. ON BOH ADJACENT SIDE TO U.S. OF STRUCTURE ABOVE. NEW WALL INFILL: NEW INFILL TO MATCH AND ALIGN WITH EXISTING CONSTRUCTION / FINISHES (U.O.N.) G.C. MATCH EXISTING WALL RATING TO MAINTAIN FIRE RATING AS APPLICABLE. NOTE: REFER TO SHT. A-211 FOR DIMENSION PLAN. NOTE: REFER TO SHT. A-212 FOR CONSTRUCTION KEY AND GENERAL NOTES. 1. GYPSUM BOARD FINISH MUST BE LEVEL (5) FOR ALL PARTITIONS. 2. GYPSUM BOARD FINISH MUST BE LEVEL (5) FOR ALL CEILING CONSTRUCTION. 3. G.C. TO PROVIDE (1) HOUR FIRE RATING (MIN.) INCLUDING DOORS AT ALL RATED WALLS SHOWN ON CONSTRUCTION PLAN. NOTE: PARTITION SEPARATING SALES FROM BACK OF HOUSE/ STOCK ROOM SHOULD BE (1) HOUR FIRE RATED WALLS (MIN.) SYMBOL LEGEND WALL LEGEND F&I BY G.C. (U.O.N) NOTES: 101 102 124 125 104 108 109 110 127 111 112 113 114 115 102 103 123B 123A 122 121120 119 118 118 118 107 106 105 128 3 A-610 2 A-610 1 A-610 4 A-610 3 A-611 2 A-611 1 A-611 4 A-611 3 A-612 2 A-612 1 A-612 4 A-612 3 A-613 2 A-613 1 A-613 4 A-613 B B B B1 B C B1 B B B B B1 B A A B B B B B B B B B B B B B1 B1 B B B B B A A B B B BBB B B D D D D D D D D D TYP., ALL SIDES D TYP., ALL SIDES D TYP., ALL SIDES D TYP., ALL SIDES G1 G1 G1G1 GG GG G TYP., ALL SIDES G TYP., ALL SIDES G1G1 G1 G1 M4 M1 M1 M3 M3M3 M3M3 M3 M1 M2M2 M2 M2 M2 M3M3 M3 M3M3 M4 H M3 M3M3 L1L1 L1L1 L1 G1G1 G GG GG1 G EE E2 E E K K4KK K4 K KK L1 K3K3K3H HH J1 JJJ E1E1 E1E1 F F E E F EE EE F E FE E E E F FE EE HL H H TYP. A-711 1 TYP. A-711 1 TYP. A-711 1 TYP. A-711 1 A-740 1 A-743 1 A-730 1 A-730 6 A-740 2 A-702 1 1 A-600 3 A-600 A-600 2/4 1 11 1 1 1 1 1 1 1 1 1 3333 3 3 3 3 3 4 5 777 7 7 7 8 8 8 8 8 8 8 8 9 9 9 9 9 9 91111 11 1111 11 11 11 12 12 14 14 14 14 14 14 15 15 1515 16 161616 16 16 18 1818 18 18 18 19 19 19 20 20 20 21 21 21 21 21 22 2221 22 22 22 22 23 23 23 23 23 23 24 24 25 2525 25 25 25 26 26 26 2629 29 29 29 31 32 33 34 35 35 36 36 37 37 38 38 39 39 40 40 41 41 41 41 41 41 42 42 42 27 30 44 45 45 46 47 47 48 48 49 50 53 1 56 19 27 27 56 LA-743 12 56 M3 M6 G1 51 52 24 42 27 27 20 12 E E 126 M2 39 E E 31 ALIGN 4 6 6 20 24 12 12 ALIGNALIGN E E 20 ALIGN 1127 C M REVISION: SHEET TITLE: SPACE NO.: ARCH PROJECT NO.: SCALE: DRAWN BY: REV. NO: SHEET NO: PRODUCT SEASON: 2018 US667-BLUE BRANSONLANDING BUILDING1000 SPACENOS.1003-1013 100BRANSONLANDINGBLVD BRANSON,MOZIP65616 AS NOTED 2018 2187-17 ISSUE DATE: 1003-1013 D.O.B. NO: 12.18.17 CLIENT/LANDLORD REVIEW 4 6 1 F R O M R O A D PARAMUS, NJ 07652 973.253.9393 TEL 973.253.9390 FAX WWW.SARGARCH.COM CONSTRUCTION PLAN 1 SCALE: 1/8" = 1'-0" CONSTRUCTION PLAN - REMOTE NIGHTBOX 2 SCALE: 1/8" = 1'-0" NORTH MH A-210 CONSTRUCTION PLANS
  • 42. 3-TIER LOCKER 3-TIER LOCKER 3-TIER LOCKER 3-TIER LOCKER 3-TIER LOCKER 3-TIER LOCKER 3-TIER LOCKER 3-TIER LOCKER 3-TIER LOCKER 3-TIER LOCKER 3-TIER LOCKER 3-TIER LOCKER 3-TIER LOCKER 3-TIER LOCKER 3-TIER LOCKER 3-TIER LOCKER 48"X30" CLR. 30"x48" 42" ROUND F WO WOEND WOSTARTWOWOWOWOENDWOSTARTWOWOWOWOEND WOSTART WO WO WO WO WO WO WO WO WO WO WO WO WO WO WO END WOSTARTWOWOWOWO WO STARTWOWOWOWOWOWOWOEND WO WO WO WO WOSTART WO WO WO WO WO WO WO END SE S E SE S E SESE SE SE SE W (LADIES) SALES AREA 001 (LAD. DIV) SALES AREA 001 (KIDS) SALES AREA 001 ROOM #1 STOCK 017 LOUNGE 014 WINDOW #4 POSTER 008 WINDOW #1 POSTER 002 WINDOW OPEN 003 WINDOW #2 POSTER 004 WINDOW DISPLAY 005 ENTRY 006 WINDOW #3 POSTER 007 ROOM ADMIN 009 MTG. RM. SECURITY 010 HALLWAY 012 CLOSET JANITOR'S 011 TOILET RM. WOMEN'S H/C 013 TOILET RM. MEN'S H/C 015 ROOM LAN 016 ROOM ELECTRICAL 018 AREA #1 FITTING RM. 019 ROOM #2 STOCK 020 AREA #2 FITTIN RM. 021 ROOM #3 STOCK 022 WINDOW #5 POSTER 023 (MENS) SALES AREA 001 NIGHTBOX REMOTE 024 EXTERIOR WO STARTWOWOWOWOWOWOWOEND WO WO STARTWOWOWOEND WOSTART WO WO WO END WO WO WO A B C D E C.3 12345678910 EXTERIOR EXTERIOR EXTERIOR EXTERIOR MALL SERVICE CORRIDOR MALL SERVICE CORRIDOR ±30'-0" (V.I.F.) ±30'-0" (V.I.F.) ±30'-0" (V.I.F.) ±30'-0" (V.I.F.) ±30'-0" (V.I.F.) ±25'-0" (V.I.F.) ±30'-0" (V.I.F.) ±30'-0" (V.I.F.) ±15'-0" (V.I.F.) ±30'-0" (V.I.F.) ±19'-2" (V.I.F.) ±10'-10" (V.I.F.) ±30'-0" (V.I.F.) ±14'-11" (V.I.F.) ±143'-93 8" LEASE LINE DIMENSION ±25'-91 8" LEASE LINE DIMENSION ±74'-81 2" LEASELINEDIMENSION ±257'-95 8" LEASE LINE DIMENSION ±61'-21 8" LEASELINEDIMENSION ±39'-115 8" LEASE LINE DIMENSION ±16'-15 8" LEASE LINE DIMENSION ±6'-27 8" LEASE LINE DIMENSION ±4'-61 2" LEASE LINE DIMENSION ±11'-4 1 8 " LEASE LINE DIMENSION ±11'-47 8 " LEASELINEDIMENSION ±6'-27 8" LEASELINEDIMENSION ±15'-9" LEASELINEDIMENSION ±28'-61 8" LEASELINEDIMENSION ±5'-0 5 8 " LEASE LINE DIMENSION 15'-21 2"3'-61 4" 8'-63 4" 17'-101 2" 7'-111 2" 26'-13 4" 3'-113 4" 26'-01 8" 8'-07 8" EQ. 3'-107 8" 22'-23 8" 7'-91 2" 22'-25 8" 7'-105 8" 25'-71 4" 4'-4" 21'-0" 3'-31 2" 2'-85 8" 16'-43 4" (9) WC 2'-33 4" 10'-71 4" 2'-4" 6'-13 4" (4) WC 2'-87 8"2'-3"16'-47 8" (9) WC 4'-101 8" 6'-17 8" (4)WC 2'-13 4"93 8"4'-17 8"8'-41 2"2'-41 8"8'-23 8" (5)WC 4'-83 8" 4'-33 4" 12'-35 8" (7) WC 2'-31 2" 2'-1" 32'-97 8" (17) WC 2'-11 4" 10'-71 4" 2'-13 8" 6'-13 4" (4) WC 3'-01 2" 6'-33 4" 3'-37 8"8'-23 8" (5)WC4'-43 8" 3'-65 8" 4'-11 4" EQ. 8'-75 8" EQ. 18'-51 2" (10) WC EQ. 8'-75 8" EQ. 4'-11 4" 3'-91 4" 4'-57 8"6'-17 8" (4)WC 2'-27 8"2'-23 4"8'-23 8" (5)WC 2'-61 2"8'-75 8"2'-63 4"6'-17 8" (4)WC 2'-27 8"51 8"8'-75 8"2'-23 4"2'-05 8" (2)WC 3'-61 2" 4'-81 8"1'-105 8"2'-67 8"16'-47 8" (9) WC 3'-105 8" 5'-05 8"8'-23 8" (5)WC 3'-75 8"8'-23 8" (5)WC 2'-103 4"3'-71 2"23'-93 8"2'-27 8"18'-51 2" (10)WC 3'-111 4" 2'-13 8"6'-17 8" (4)WC 3'-35 8" 2'-51 8" 6'-17 8" (4) WC 2'-23 8" 8'-71 2" 2'-23 8" 4'-11 4" (3) WC 2'-23 8" 7'-6" 2'-1" 6'-17 8" (4) WC 3'-71 8" 4'-2" 4'-17 8" (3)WC 2'-21 2" 2'-7" 6'-17 8" (4) WC 4'-10" 3'-93 4"6'-17 8" (4)WC 2'-27 8"2'-27 8"6'-17 8" (4)WC 3'-83 4" 3'-9"6'-17 8" (4) WC 2'-27 8"2'-25 8"8'-23 8" (5) WC 2'-31 8"8'-75 8"71 2"2'-31 4"10'-3" (6) WC 4'-41 8" 3'-57 8"4'-11 4" (3)WC 2'-27 8" 3'-43 8" 30'-91 8" (16) WC 1'-23 4" 1'-27 8"8'-23 8" (5)WC 2'-5" 111 4" 6'-17 8" (4) WC 3'-9" 2'-07 8"38'-111 2" (20)WC 1'-53 4"83 8"4'-11 4" (3)WC 3'-37 8" 2'-65 8"45'-13 8" (23) WC 97 8"57 8" 10'-3" (6) WC 1'-21 8" 2'-33 4" 12'-35 8" (7)WC 113 8" 22'-77 8" 12'-87 8" 5'-10" 31'-07 8" 7'-01 2" 4'-51 8"4'-51 8" 10'-11 2" 1'-105 8" 2'-61 2" 13'-83 8" 10'-11" 18'-107 8" 4'-111 8" 63'-1" 39'-31 8" 86'-01 4" 1'-33 4" 60'-01 2" 1'-33 4" 66'-11 2" 24'-73 4" 22'-31 8" 13'-15 8" 101'-101 8" 60'-01 2" 1'-33 4" 66'-11 2" 1'-37 8" 127'-55 8" 16'-101 2"15'-11 8"63'-2" 214'-95 8" 16'-101 2"16'-47 8"9'-21 8" 42'-53 8" 113 8"4'-11 4" (3)WC 2'-93 4" 35'-41 4" 5'-103 8" 13'-77 8" 12'-13 4" 29'-107 8"1'-33 4"53'-43 4" 2'-81 4" 2'-81 4" 2'-81 4" 2'-81 4" 2'-81 4" 2'-81 4" 2'-81 4" 2'-81 4" 2'-81 4" 2'-81 4" 2'-81 4" 2'-81 4" 2'-81 4" 2'-81 4" 2'-81 4" 2'-81 4" 2'-81 4" 2'-81 4" 2'-81 4" 2'-81 4" 2'-81 4" 2'-81 4" 2'-81 4" 2'-81 4" 2'-81 4" 2'-81 4" 2'-81 4" 2'-81 4" 20'-93 8" 13'-11 8" 8'-01 8" 4'-51 8" 8'-55 8" 7'-01 2" 6'-47 8" 3'-43 4" 3'-3" 3'-5" 6'-31 8" 2'-31 8" 1'-71 8" 17'-101 2" EQ. EQ. 3'-101 2" 6'-91 2" 5'-71 4" 13'-25 8" 2'-17 8" 4'-05 8" 5'-81 8" 3'-33 8" 6'-15 8" (4) WC 6'-5" 7'-10" 111 2" 11'-07 8" 2'-1"5'-67 8"3'-13 8" 1'-41 8" 3'-31 4" 2'-01 8" 2'-01 8" 3'-37 8" 3'-7" 14'-11 2" LEASELINEDIMENSIONS 25'-2" LEASE LINE DIMENSIONS 2'-57 8" CLOF CASHWRAP CLOF LIGHTBOX 6'-0" 6'-0"EQ. EQ. 5'-10" 5'-10"3'-7"EQ. EQ. REVISION: SHEET TITLE: SPACE NO.: ARCH PROJECT NO.: SCALE: DRAWN BY: REV. NO: SHEET NO: PRODUCT SEASON: 2018 US667-BLUE BRANSONLANDING BUILDING1000 SPACENOS.1003-1013 100BRANSONLANDINGBLVD BRANSON,MOZIP65616 AS NOTED 2018 2187-17 ISSUE DATE: 1003-1013 D.O.B. NO: 12.18.17 CLIENT/LANDLORD REVIEW 4 6 1 F R O M R O A D PARAMUS, NJ 07652 973.253.9393 TEL 973.253.9390 FAX WWW.SARGARCH.COM DIMENSION PLAN 1 SCALE: 1/8" = 1'-0" NORTH DIMENSION PLAN - REMOTE NIGHTBOX 2 SCALE: 1/8" = 1'-0" NOTE: REFER TO SHT. A-212 FOR CONSTRUCTION KEY AND GENERAL NOTES. REFER TO SHT. A-740 FOR BOH DIMENSIONS SYMBOL DESCRIPTION SM/CM SPECIAL MIRROR/CLEAR MIRROR. SEE COLUMN ENCLOSURE SHTS. & FITTING ROOM SHTS. FOR MORE INFO. WC. WALL CHANNEL. RC. RECESSED CHANNEL ABBREVIATION LEGEND MH A-211 DIMENSION PLANS
  • 43. REVISION: SHEET TITLE: SPACE NO.: ARCH PROJECT NO.: SCALE: DRAWN BY: REV. NO: SHEET NO: PRODUCT SEASON: 2018 US667-BLUE BRANSONLANDING BUILDING1000 SPACENOS.1003-1013 100BRANSONLANDINGBLVD BRANSON,MOZIP65616 AS NOTED 2018 2187-17 ISSUE DATE: 1003-1013 D.O.B. NO: 12.18.17 CLIENT/LANDLORD REVIEW 4 6 1 F R O M R O A D PARAMUS, NJ 07652 973.253.9393 TEL 973.253.9390 FAX WWW.SARGARCH.COM 1. G.C. IS RESPONSIBLE TO FIELD-VERIFY ALL EXISTING CONDITIONS & DIMENSIONS IN THE SPACE. FAILURE TO PROPERLY VERIFY EXISTING CONDITIONS DOES NOT RELIEVE G.C. OF ANY EXPENSES OR RESPONSIBILITIES RESULTING FROM THAT FAILURE. 2. CONTRACTOR TO PROVIDE PARTITION LAYOUT FOR ARCHITECT'S/ H&M'S APPROVAL BEFORE CONSTRUCTION FOR CONFIRMATION OF ALL DIMENSIONS. G.C. TO COORDINATE ALL DIMENSIONS WITH H&M FIXTURE DIMENSIONS. 3. SEE FITTING ROOM ENLARGED PLANS, ELEVATIONS, & DETAILS SHEET FOR FITTING ROOM LAYOUT. 4. G.C. TO PROVIDE SHOP DRAWINGS FOR ARCHITECT'S APPROVAL BEFORE FABRICATION OF ALL FINISHES, HARDWARE & COMPONENTS. SEE SHOP DWG. LIST ON GENERAL NOTES & RESPONSIBILITY SCHEDULE SHEET. 5. IN CASE OF DISCREPANCY BETWEEN ARCHITECT'S & ENGINEER'S DRAWINGS, THE MORE STRINGENT, HIGHER QUANTITY OR HIGHER QUALITY SHALL PREVAIL. CONTRACTOR TO INFORM ARCHITECT & H&M PROJECT MANAGER OF ANY DISCREPANCIES PRIOR TO SUBMITTING BID. 6. G.C. TO VERIFY ALL DIMENSIONS OF MILLWORK, FIXTURES & FITTING ROOMS WITH H&M PRIOR TO LAYOUT. 7. G.C. TO PATCH, REPAIR AS REQUIRED & PAINT ALL GYP. BD. COLUMN WRAPS & EXPOSED AREAS AT EXISTING WINDOW WALLS & ALL EXISTING GYP. BD. 8. G.C. TO COORDINATE CONSTRUCTION TIMING WITH H&M SCHEDULE PRIOR TO CONSTRUCTION START. ANY CHANGE TO CONSTRUCTION SCHEDULE MUST BE SENT TO H&M PM FOR REVIEW & APPROVAL. 9. ALL PLYWOOD BACKING/BLOCKING IS FIRE RESISTANT (F.R.) / FIRE RETARDANT TREATED (FRT). 10. G.C. IS RESPONSIBLE FOR PROVIDING ALL BRACING /BLOCKING AS REQUIRED BY CODE & STRUCTURAL NECESSITY FOR ALL FIXTURES AFFIXED TO WALLS AND CEILINGS. SEE FIXTURE DETAILS & PARTITION TYPES FOR CONNECTION DETAILS. 11. SEE MEP DRAWINGS FOR ADDITIONAL NOTES. 12. ALL WORK TO COMPLY WITH ALL APPLICABLE LOCAL, STATE & FEDERAL BY-LAWS & CODE REQUIREMENTS. 13. G.C. TO PROTECT & MAINTAIN EXISTING FIRE PROOFING AROUND COLUMN & BEAMS & ALL STRUCTURAL MEMBERS TYPICAL THROUGHOUT. REPAIR/REPLACE ANY DAMAGED FIREPROOFING AS REQ'D. DUE TO CONSTRUCTION. 14. EXISTING STRUCTURAL SLAB SHALL NOT BE TRENCHED, CUT OR DAMAGED IN ANY WAY WITHOUT WRITTEN DIRECTION FROM STRUCTURAL E.O.R. & APPROVAL BY THE LANDLORD. 15. COORDINATE EXACT SAFE LOCATION WITH H&M. G.C. TO PROVIDE NECESSARY SUPPORT FOR SAFE. 16. G.C. TO PROVIDE ALL NECESSARY SIGNS (INCL. THOSE PER CODE FOR ACCESSIBILITY) FOR TOILETS, FITTING ROOMS, STAIRS, ELEVATORS (AS REQ'D.). 17. G.C. TO PROVIDE ALL BOH CORNER GUARDS. 18. G.C. IS SOLELY RESPONSIBLE TO TEST MOISTURE CONTENT OF SUB-FLOOR PRIOR TO INSTALLATION OF ALL FINISH FLOORING MATERIALS & MAINTAIN PROPER TEMPERATURE & HUMIDITY LEVELS PER MANUFACTURERS SPECIFICATIONS. 19. H&M ELEVATOR IS NOT TO BE UTILIZED BY G.C. FOR ANY PURPOSES. 20. NOTHING IS PERMITTED TO ATTACH TO, SUSPENDED FROM, OR PENETRATE ROOF DECK. G.C. MAY ONLY ATTACH TO TOP CHORD OF JOIST(S) OR I-BEAMS PER LANDLORD REQUIREMENT. ALL WALL/CLG./OVERHEAD CONSTRUCTION TO BE SUPPORTED IN THIS MANNER. NO WELDING OR SHOOTING INTO STRUCTURE IS PERMITTED. COORDINATE EXTENT OF EXACT REQUIREMENTS WITH LANDLORD'S REP. 21. STRUCTURAL REINFORCING DETAILS TO BE PROVIDED BY A REGISTERED STRUCTURAL ENGINEER TO LANDLORD FOR APPROVAL AS WELL AS FOR COORDINATION OF EQUIPMENT SUPPORT OR SUSPENSION, SERVICE PLATFORMS, DECK PENETRATIONS, ETC. (AS REQ'D.) 22. ANY LANDLORD EQUIPMENT OR COMPONENT EXISTING IN THE SPACE MUST REMAIN VISIBLE & ACCESSIBLE. G.C. TO COORD. ANY REQ'D ACCESS W/H&M PM, LANDLORD REP. & ARCHITECT. 23. ALL CONCRETE PATCHING MUST BE LEVEL WITH EXISTING CONCRETE FLOOR. 24. G.C. TO COORDINATE ALL RATED WALLS WITH M.E.P. DRAWINGS. PROVIDE FIRE &/OR FIRE/SMOKE DAMPERS &/OR FIRE CAULKING (AS REQ'D.). 25. G.C. TO INSTALL ALL ELECTRICAL DEVICES & EQUIPMENT AT CENTERLINE OF COLUMN FACE, TYP., U.O.N. 26. DO NOT SCALE THESE DRAWINGS. USE WRITTEN DIMENSIONS ONLY. SUBMIT TO ARCHITECT ANY DISCREPANCIES FOR CLARIFICATION. REFER TO RESPONSIBILITY SCHEDULE. 27. PROVIDE ACCESSIBILITY FOR PHYSICALLY HANDICAPPED PER (APPLICABLE ACCESSIBILITY CODE). 28. G.C. TO ENSURE ALL INTERIOR WALL BLOCKING IS INSTALLED PRIOR TO APPLYING WALL FINISHES. COORDINATE LOCATION OF BLOCKING WITH H&M FIXTURE MANUFACTURERS. 29. NEW STOREFRONT GLAZING TO BE TEMPERED SAFETY GLASS. ALL EDGES MUST BE GROUND & POLISHED. 30. ALL FLOOR ELECTRICAL BOXES TO BE INSTALLED FLUSH W/ NEW FLOORING AT CASHWRAP & FIXTURES W/ POWER AS SHOWN ON ELECTRICAL SHEETS. REFER TO FLOOR & MISC. DETAILS SHEET & ELECTRICAL DRAWINGS. 31. G.C. TO VERIFY ALL COLUMN LOCATIONS & CONDITIONS. NOTIFY ARCHITECT OF ANY DISCREPANCIES. ALL GYP. BD. SURFACES TO BE A LEVEL 5 FINISH PRIOR TO PAINTING. 32. SAW CUTTING (ALLOWED IN SLAB-ON-GROUND CONDITIONS ONLY) & CORE DRILLING MUST OCCUR OUTSIDE OF MALL OPERATING HOURS. COORD. W/ MALL'S REP. 33. ALL FLOOR PENETRATIONS MUST BE SLEEVED & SEALED LIQUID TIGHT. FIRE-STOPPING IS REQUIRED USING APPROPRIATE UL METHOD. 34. G.C. TO FIREPROOF ALL NEW STRUCTURAL ELEMENTS TO INCLUDE BUT NOT LIMITED TO BEAMS, JOISTS, COLUMNS, ETC. AS REQ'D. PER LL OR GOVERNING CODE. G.C. TO MATCH NEW FIREPROOFING WITH EXISTING. 35. G.C. TO VERIFY ALL DIMENSIONS OF MILLWORK, FIXTURES, AND FITTING ROOMS WITH H&M PRIOR TO LAYOUT INCLUDING BUT NOT LIMITED TO BLOCKING HEIGHTS. 36. ALL PLYWOOD BACKING/BLOCKING IS FIRE RESISTANT. G.C. RESPONSIBLE FOR PROVIDING ALL BRACINGS/BLOCKING REQUIRED BY CODE AND STRUCTURAL NECESSITY FOR ALL FIXTURES, SIGNAGE, LIGHTING, ETC. AFFIXED TO WALLS AND CEILINGS. ALL EXPOSED HOOD TRIM IS NOT REQUIRED TO BE FRT 37. COORDINATE WITH MECHANICAL DRAWINGS FOR SIZE & LOCATIONS OF RETURN AIR LOUVERS IN CEILING OR WALLS. 38. G.C. TO PROCURE AN OFF-SITE STORAGE FACILITY FOR STORAGE OF ALL DELIVERED MATERIALS, FIXTURES, ETC. FOR CONSTRUCTION OF STORE. G.C. HAS 48 HOURS UPON RECEIPT OF ANY ITEM TO CHECK-IN SAID ITEM & NOTE ANY DAMAGE OF ITEM. G.C. TO NOTIFY H&M OF ANY DAMAGED ITEM(S) WITHIN THIS 48 HOUR PERIOD. IF NO NOTIFICATION OCCURS WITHIN THE 48 HOUR PERIOD, G.C. ASSUMES RESPONSIBILITY FOR CONDITION OF ITEM. 39. G.C. TO BEGIN CONSTRUCTION OF LEASED SPACE WITH INSTALLATION OF FLOOR TILE AFTER DEMOLITION IS COMPLETED IN PHASE. ALL OTHER NEW CONSTRUCTION SHALL OCCUR ON TOP OF FLOOR TILE. AFTER FLOOR TILE HAS BEEN INSTALLED G.C. TO COVER TILE WITH PLYWOOD (OR OTHER MATERIAL APPROVED BY H&M). AFTER FLOOR TILE HAS BEEN INSTALLED G.G. SHALL NOT ALLOW THE USE OF LIFTS FOR ANY FURTHER CONSTRUCTION OF THE LEASED SPACE. 40. ALL ANTI-THEFT WIRING DIMENSIONS & LOCATIONS BY TENANT VENDOR. 41. WARDROBE TOP CONNECTORS TO BE INSTALLED BEHIND WARDROBE HEADER CONNECTORS AND NOT TO BE EXPOSED TO SALES FLOOR. 42. ALL PLUMBING WALLS ARE TO BE 6" METAL STUD CONSTRUCTION. 43. DRYWALL AT DEMISING WALLS MUST CONTINUE TO METAL DECK (MUST BE FIRE TAPED OR FIRE CAULKED TO DECK AS REQ'D BY CODE). ABOVE, TO BE TAPED & PRIMED TO ABOVE FINISH CEILING ELEVATION OR DESIGNATED SALES AREA HT IN OPEN CLG. 44. ALL WORK SHALL BE IN LOCAL COMPLIANCE W/ ADOPTED LOCAL CODES, AIA A-210 CONDITIONS OF CONTRACT FOR CONSTRUCTION, RECOGNIZED INDUSTRY STANDARDS IN THE AREA, ALL MANUFACTURERS RECOMMENDATIONS, & ALL OTHER APPLICABLE CODES. 45. G.C. TO VERIFY WITH LANDLORD THE MAXIMUM DEPTH OF ANY PENETRATIONS OR ANCHORS INTO THE SLAB BEFORE SLAB WORK BEGINS SYMBOL DESCRIPTION TENANT LEASE LINE. PROJECT TEAM TO VERIFY IN FIELD. STOREFRONT LEASE LINE AT POP-OUT. PROJECT TEAM TO VERIFY IN FIELD. NEW STOREFRONT ENTRY & SAFETY GLASS GLAZING SYSTEM; REFER TO GENERAL NOTES/RESPONSIBILITY SCHEDULE & STOREFRONT SHTS. FOR MORE INFO. NEDAP STOREFRONT SECURITY ANTENNA PANEL SYSTEM-SUPPLIED AND INSTALLED BY TENANT VENDOR. ANTENNAS NOT TO BE PLACED MORE THAN 5'-10" APART. G.C. TO COORDINATE LOCATION WITH STORE FIXTURES. VENDOR TO SUBMIT SHOP DRAWINGS TO ARCHITECT FOR REVIEW AND APPROVAL. G.C. TO CORE, PATCH CONCRETE SLAB AND PROVIDE CONDUIT FOR LOSS PREVENTION SECURITY PEDESTAL. COORDINATE WITH H&M VENDOR AND ELECTRICAL DRAWINGS PRIOR TO ROUGH-IN. G.C. TO PROVIDE AND INSTALL ±7'-0" H. METAL SCREEN (MTL. MESH SCREEN OR EQUAL) BEHIND GYP. BD. AT ENTRY AREA. SEE A-601 FOR SPEC & MORE INFO. G.C. TO COORDINATE WITH H&M P.M. FOR LOCATION AND FOR MORE INFORMATION. STOREFRONT WINDOWS PODIUM AND TRENCH TO BE BUILT AND INSTALLED BY G.C. REFER TO FIXTURE AND STOREFRONT SHTS. FOR MORE INFORMATION. G.C. TO PROVIDE AND COORDINATE ELECTRICAL REQUIREMENTS OF PLATFORM (TYP.) SEE ELEC. DRAWINGS. G.C. TO PROVIDE SHOP DRAWINGS FOR APPROVAL PRIOR TO FABRICATION. VINYL APPLIED TO INSIDE OF GLASS, ACCORDING TO H&M "STORE INSTRUCTIONS". WALLPAPER APPLIED TO BACK WALL & SIDES ACCORDING TO H&M "STORE INSTRUCTIONS". WALL & SIDES TO BE PAINTED WHITE PRIOR TO WALLPAPER APPLICATION. PARTIAL HEIGHT FRAMELESS GLASS DISPLAY DOOR PROVIDED AND INSTALLED BY G.C. COORDINATE FINAL INSTALLATION WITH H&M PROJECT MANAGER. REFER TO SHT. A-800 FOR MORE INFORMATION.. 1 2 3 4 5 6 7 8 9 10 FULL HEIGHT FLUSH WOODEN DISPLAY DOOR PROVIDED AND INSTALLED BY G.C. COORDINATE FINAL INSTALLATION WITH H&M PROJECT MANAGER. REFER TO SHT. A-800 FOR MORE INFORMATION.. DASHED LINE OF PAINTED GYP. BD. SOFFIT/HEADER ABOVE. SEE RCP SHT. FOR MORE INFO. DASHED LINE OF LIGHT COVE ABOVE IN POSTER WINDOWS. SEE STOREFRONT SECTION & DETAILS FOR MORE INFO. PROJECT TEAM TO FIELD VERIFY ANY NEW UTILITIES INSTALLED BY LANDLORD PRIOR TO START OF CONSTRUCTION AND NOTIFY OWNER IN WRITING OF FINDINGS. ALL PLAN DIMENSIONS TO FINISH FACE OF PARTITION UNLESS NOTED OTHERWISE. FACE OF GYP. BD. WALLS, UNLESS OTHERWISE NOTED. ALL "EQ - EQ" DIMENSIONS ARE CONSIDERED TO BE MEASURED FROM ADJACENT ARCHITECTURAL OR FIXTURE ELEMENT ON PLAN. G.C. TO PROVIDE & INSTALL TYPE 'X' 5/8" THK. GYP BD. WHERE GYP. BD. IS NOT EXISTING ON TENANT SIDE OF DEMISING WALLS. FIRE TAPE, CAULK, & SEAL AS REQUIRED TO MAINTAIN RATING PER CODE. RATING TO BE 1 HR. (UL#465) U.N.O. G.C. TO PROVIDE & INSTALL TYPE 'X' 5/8" THK. GYP BD. AT STOREFRONT ON LANDLORD'S BASE AND WHERE GYP. BD. IS NOT EXISTING ON TENANT SIDE OF LANDLORD BULKHEAD. FIRE TAPE, CAULK, & SEAL AS REQUIRED TO MAINTAIN RATING PER CODE. PROVIDE NEW OR REPAIR EXISTING SPRAY-ON FIREPROOFING (WHERE APPLICABLE) TO MAINTAIN RATING AT ALL EXISTING OR NEW COLUMNS, BEAMS, AND FLOOR DECKS IF REQUIRED. TYPICAL FOR ENTIRE H&M LEASED AREA. HOLD COLUMN ENCLOSURE AS TIGHT AS POSSIBLE ON ALL SIDES. ENSURE COLUMN IS BUILT OUT LARGE ENOUGH TO ENCASE STANDARD DEPTH ELECTRICAL 1900 JUNCTION BOX, CONDUIT FOR RECESSED DATA LOCATIONS, AND RECESSED FIRE EXTINGUISHER CABINET, IF REQ'D. SEE MEP DRAWINGS AND EGRESS PLAN FOR MORE INFORMATION. EMERGENCY FIRE PULL. REFER TO M.E.P. DRAWINGS LOCATIONS & FOR MORE INFORMATION. G.C. TO INSTALL CLEAR SIGNAGE INDICATING EXIT ROUTE (AS REQ'D. BY AHJ). G.C. TO SUPPLY & INSTALL EMERGENCY EVACUATION MAPS. MAPS TO BE LAMINATED, LEGIBLE, AND EASILY VISIBLE. SEE EGRESS SHT. FOR MORE INFORMATION. CONFIRM FINAL LOCATION WITH H&M PM. 11 12 13 14 15 16 17 18 19 20 21 22 G.C. TO FIRE RATE ALL PENETRATIONS WITHIN TENANT SPACE (AS APPLICABLE) TO MEET CODE REQUIREMENTS. G.C. TO PROVIDE RECEPTACLE/POWER FOR RECHARGEABLE FLASHLIGHT. REFER TO EGRESS SHT. FOR MOUNTING HEIGHT AND MORE INFORMATION. G.C. TO PROVIDE AND INSTALL 2A10BC FIRE EXTINGUISHER PER NFPA 10 TO BE INSTALLED AT LOCATIONS SHOWN UNLESS DIRECTED OTHERWISE BY FIRE MARSHALL. G.C. TO INSTALL "FOAM" TYPE EXTINGUISHERS IN ALL BACK OF HOUSE AREAS, "WATER" TYPE EXTINGUISHERS IN ALL SALES FLOOR AND FITTING ROOM AREAS, AND "CO2" TYPE EXTINGUISHERS IN ALL ELECTRICAL AND LAN. ROOM AREAS (IF ALLOWABLE PER CODE). ALL FIRE EXTINGUISHERS SHALL BE CLEARLY MARKED WITH A SIGN PLACED AT MINIMUM 5'-10 7/8" A.F.F. AND MAXIMUM OF 6'-6 3/4" A.F.F. ENSURE THAT THERE IS ADEQUATE SPACE IN WALL FOR RECESSED FIRE EXTINGUISHER CABINETS, IF REQ'D. REFER TO EGRESS SHT. FOR MORE INFORMATION. LOCATION OF PVM (PUBLIC VIEW MONITOR) AT NEAREST COLUMN TO THE STOREFRONT ENTRY & OUTSIDE FITTING ROOM PORTAL. CCTV VENDOR IS RESPONSIBLE FOR ALL MONITOR LOCATIONS AND EQUIPMENT COORDINATION WITH H&M PM. G.C. TO PROVIDE BLOCKING AS REQ'D. REFER TO VENDOR SHOP DRAWINGS FOR EXACT LOCATIONS. SEE DETAIL 1/A-322 & 'E' SHTS. FOR MORE INFO. FIXTURE TO BE SECURED TO FLOOR. REFER TO H&M INTERIOR INSTRUCTIONS FOR APPROPRIATE SEASON & YEAR - FOR INSTALLATION REQUIREMENTS (SEE FIXTURE DETAILS FOR MORE INFO.) WARDROBES, DIVIDERS AND OTHER FIXTURES W/INTEGRATED LIGHTING. J-BOXES TO BE COORDINATED WITH H&M INSTALLATION INSTRUCTIONS AND FIXTURE VENDOR. SEE FIXTURE PLAN SHT. & "E" SHTS. FOR MORE INFO. FIXTURE MIRROR LOCATIONS SHOWN ARE NOT NECESSARILY INDICATIVE OF FINAL LOCATIONS. G.C. SHALL COORDINATE WITH H&M REP. PRIOR TO INSTALLATION ANY AND ALL MIRRORS. COORDINATE LOCATION OF FIRE ALARM HORNS, STROBES, PULL STATIONS, ETC.(IF REQ'D.) MIRROR LOCATIONS SHOULD BE TAKEN INTO CONSIDERATION BEFORE MOUNTING DEVICES. COORDINATE FINAL LOCATIONS WITH H&M ON-SITE PROJECT MANAGER. THE DEVICES SHOULD NOT BE PLACED ON THE SAME FACE AS FIXTURE MIRROR (AT COLUMNS). G.C. TO COORDINATE AND ALERT OWNER/ARCHITECT WHERE THESE CONFLICTS OCCUR PRIOR TO PLACEMENT OR INSTALLATION. IF PLACEMENT IS DIRECTED BY ANY, G.C. SHALL NOTIFY H&M OF ANY CONFLICT. SPECIAL MIRROR ON COLUMN/PORTAL, PROVIDED AND INSTALLED BY G.C. G.C. SHALL COORDINATE WITH H&M REP. PRIOR TO INSTALLATION ANY AND ALL MIRRORS. COORDINATE LOCATION OF FIRE ALARM HORNS, STROBES, PULL STATIONS, ETC. (IF REQ'D.). MIRROR LOCATIONS SHOULD BE TAKEN INTO CONSIDERATION BEFORE MOUNTING DEVICES. COORDINATE FINAL LOCATIONS WITH H&M ON-SITE PROJECT MANAGER. THE DEVICES SHOULD NOT BE PLACED ON THE SAME FACE AS MIRROR (AT COLUMNS). G.C. TO COORDINATE AND ALERT OWNER/ARCHITECT WHERE THESE CONFLICTS OCCUR PRIOR TO PLACEMENT OR INSTALLATION. IF PLACEMENT IS DIRECTED BY LOCAL GOVERNING JURISDICTION, G.C. SHALL NOTIFY H&M OF CONFLICT. REFER TO FINISH PLAN SHT. FOR LOCATIONS. REFER TO COLUMN ENCLOSURE DETAILS SHTS. FOR MORE INFO. EMPLOYEE ENTRANCE. PROVIDE CARD READER ACCESS TO STORE IF NOT ALREADY EXISTING. POWER TO DOOR FOR DELAYED ACTION EGRESS WITH OVERRIDE FROM FIRE ALARM SYSTEM. G.C. TO INSTALL DOOR VIEWER, AND DOORBELL. VENDOR TO INSTALL INTERCOM AT EMPLOYEE ENTRANCE. REFER TO ELECTRICAL SHTS. FOR MORE INFORMATION. OWNERS VENDOR TO INSTALL CCTV CAMERA ON OUTSIDE OF ADMIN. OFFICE DOOR WITH MONITOR INSTALLED ON INSIDE OF DOOR. REFER TO M.E.P. & SHOP DRAWINGS FOR MORE INFORMATION.. HANDICAPPED CASHWRAP PROVIDED BY H&M AND INSTALLED BY G.C. 3'-0" CLEAR REQUIRED BETWEEN FACE OF WARDROBE UNITS AND FACE OF CASHWRAPS FOR TOTAL LENGTH OF LAYOUT. 5'-0" CLEAR WIDTH REQUIRED AREA IF ACCESS IS JUST FROM ONE SIDE. HEIGHT OF COUNTER TOP TO COMPLY WITH ICC/ANSI A117.1, SECTION 904 AND ADA AG. REFER TO FIXTURE SHTS. FOR MORE INFORMATION. 23 24 25 26 27 28 29 30 31 32 33 G.C. TO CUT, PATCH CONC. SLAB AND PROVIDE CONDUIT AND ELEC. SERVICE FOR CASHWRAP. G.C. TO COORDINATE W/ H&M VENDOR, ELEC. DWGS, SHOP DWGS, AND MANUFACTURER PRIOR TO ROUGH-IN. REFER TO ENLARGED FITTING ROOM PLANS ON SHT. A-730 SERIES FOR INFORMATION. REGARDING ADA COMPLIANCE, PARTITIONS AND ALL FITTING ROOM FIXTURES. G.C. TO PROVIDE 1/2" THK. F.R.T. PLYWOOD BLOCKING AT ALL FITTING ROOM INTERIOR WALLS FOR ALL FITTING ROOM FIXTURING. NEW HOOKS THAT WILL BE MOUNTED AT 5'-0" O.C. IN ALL FITTING ROOMS EXCEPT FOR THE ADA FITTING ROOM WHICH SHALL BE MOUNTED AT 48" A.F.F. REFER TO FIXTURE SHOP DRAWINGS AND H&M REP. FOR BLOCKING HEIGHTS. ALL FITTING ROOM CURTAINS, FRAMES, WARDROBES AND HARDWARE FURNISHED BY TENANT, INSTALLED BY G.C. GENERAL CONTRACTOR TO COORDINATE WITH H&M'S FIXTURE CONTRACTOR FOR FINAL DIMENSIONS. PROVIDE ADA INTERNATIONAL SIGN FOR ACCESSIBILITY AT ALL ADA DRESSING COMPARTMENTS. INTERNALLY ILLUMINATED STOREFRONT SIGN BY TENANT SIGN VENDOR. G.C. TO COORDINATE WITH STOREFRONT SHTS AND SIGN SHOP DRAWINGS FOR PROPER MOUNTING (PENDANT HUNG FROM CEILING/SOFFIT ABOVE, FLUSH OR RECESSED 'PUSH-THRU') G.C. TO PROVIDE POWER AND BLOCKING PRIOR TO VENDOR INSTALLATION. REFER TO STOREFRONT SHTS. AND SIGNAGE SHOP DRAWINGS FOR MORE INFORMATION. STOREFRONT BLADE SIGN BY SIGN VENDOR LANDLORD'S. G.C. TO COORDINATE INSTALLATION WITH SIGN VENDOR. REFER TO STOREFRONT SHTS. FOR MORE INFORMATION. TYP., SEE CONSTRUCTION PLAN FOR LOCATIONS. FREE-STANDING LIGHTBOX AND/OR LOGO WALL FIXTURE PROVIDED BY H&M & INSTALLED BY G.C.; PROVIDE & INSTALL ALL ELECTRICAL REQUIREMENTS FOR LIGHTBOX & ASSOCIATED SIGNAGE. COORDINATE HEIGHT OF J-BOX WITH LIGHTBOX SPECIFICATIONS. REFER TO ELECTRICAL DRAWINGS, H&M PROJECT MANAGER & H&M-PROVIDED "IPS DRAWINGS, CATALOGUES & CONSTRUCTION INFORMATION.". LIGHT BOX FIXTURE SURFACE MOUNTED ON WALL PROVIDED BY H&M AND INSTALLED BY G.C. G.C. TO PROVIDE AND INSTALL IN-WALL F.R.T. PLYWOOD BLOCKING AS REQUIRED. G.C. SHALL SUPPLY AND INSTALL ALL ELECTRICAL REQUIREMENTS FOR LIGHT BOX AND ASSOCIATED SIGNAGE. COORDINATE HEIGHT OF J-BOX WITH LIGHT BOX SPECIFICATIONS. REFER TO ELECTRICAL DRAWINGS, H&M PROJECT MANAGER, AND H&M PROVIDED "IPS DRAWINGS, CATALOGUES, AND CONSTRUCTION INFORMATION." FOR MORE INFORMATION. 34 35 36 37 38 39 40 41 42 LIGHT BOX FIXTURE RECESSED MOUNTED ON WALL PROVIDED BY H&M AND INSTALLED BY G.C., CENTERED BEHIND CASHPOINTS ABOVE CASHWRAP ON STOREFRONT FACADE OR INTERIOR PARTITION (SEE PLAN FOR EXACT LOCATIONS). SEE SIGNAGE DETAIL SHT. FOR MORE INFORMATION. G.C. TO PROVIDE AND INSTALL IN-WALL F.R.T. PLYWOOD BLOCKING AS REQUIRED. G.C. SHALL SUPPLY AND INSTALL ALL ELECTRICAL REQUIREMENTS FOR LIGHT BOX AND ASSOCIATED SIGNAGE. COORDINATE HEIGHT OF J-BOX WITH LIGHT BOX SPECIFICATIONS. REFER TO ELECTRICAL DRAWINGS, H&M PROJECT MANAGER, AND H&M PROVIDED "IPS DRAWINGS, CATALOGUES, AND CONSTRUCTION INFORMATION." FOR MORE INFORMATION. LED STORE GUIDE (SURFACE MTD. ON WALL OR FREESTANDING) PROVIDED BY H&M AND INSTALLED BY G.C. G.C. TO PROVIDE AND INSTALL IN-WALL F.R.T. PLYWOOD BLOCKING AS REQUIRED. G.C. SHALL SUPPLY AND INSTALL ALL ELECTRICAL REQUIREMENTS FOR STORE GUIDE. COORDINATE HEIGHT OF J-BOX WITH STORE GUIDE SPECIFICATIONS. REFER TO SHT. A-551, 'E' DRAWINGS, H&M PROJECT MANAGER, AND H&M PROVIDED "IPS DRAWINGS, CATALOGUES, AND CONSTRUCTION INFO." FOR MORE INFO. REFER TO ELECTRICAL DRAWINGS FOR ROOM REQUIREMENTS. G.C. TO INSTALL PVC PIPE DRAWING TUBE IN ELECTRICAL ROOM. REFER TO DETAIL ON SHT. 8/A-750 FOR MORE INFORMATION., AND H&M PROJECT MANAGER FOR EXACT LOCATION. G.C. TO ADD ONE (1) LAYER OF CONT. 3/4" F.R.T. PLYWOOD ON ALL WALLS OF LAN. ROOM AND ELECTRICAL ROOM FOR ALL ELECTRICAL/DATA/ETC. EQUIPMENT. REFER TO PARTITION TYPES ON SHEET A-700 FOR MORE INFORMATION. G.C. TO INSTALL FIRE RATED PLYWOOD FROM FINISHED FLOOR TO 8'-0" A.F.F.. G.C. TO INSTALL PLYWOOD "STAMP-SIDE OUT" SO FIRE RATING STAMP IS VISIBLE AFTER INSTALLATION. (DO NOT PAINT) REFER TO FIXTURE PLAN & BOH SHTS. FOR STOCK ROOM LAYOUT & FIXTURES. APPROXIMATE LOCATION OF IRON OUTLET. SEE ELECTRICAL SHTS. FOR MORE INFO. G.C. TO PROVIDE COVER PLATES FOR ALL EXISTING FLOOR DRAINS, AS REQ'D G.C. TO PROVIDE SERVICE ENTRANCE DOOR SIGN. DELIVERY DOOR WITH DOORBELL. PRIVACY FROSTED WINDOW FILM (OR LIFESTYLE GRAPHIC) PROVIDED BY H&M. INSTALLED BY G.C. NEW ENTRY VESTIBULE AND DOORS BY H&M - REFER TO GENERAL NOTES/RESPONSIBILITY SCHEDULE & STOREFRONT SHTS. FOR MORE INFORMATION.. APPROXIMATE LOCATION OF EXISTING EXPANSIONS JOINT IN TENANT SPACE, G.C. TO V.I.F. STAIR + PLATFORM ACCESS TO DISPLAY WINDOW. 43 44 45 46 47 48 49 50 51 52 53 54 55 56 CONSTRUCTION GENERAL NOTESCONSTRUCTION KEY NOTES GENERAL AND KEY NOTES MH A-212 CONSTRUCTION PLAN NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED
  • 44. EQ.EQ. EQ.EQ. EQ.EQ. EQ.EQ. EQ.EQ. EQ.EQ. EQ.EQ. EQ.EQ. EQ.EQ. EQ.EQ. EQ.EQ. EQ.EQ. CL CL CL CLCLCL CL CL CL CL CLCL 30"x48" PREPARE OUTLET FOR IRON 42" ROUND FITTING ROOM S2S3 S1 LADIES S2S3 S1 C H4 H4 H3 H3 H3 H3 G H4 H4 G G G G G G G G G G G G G G G G G G G H3 H3 H3 H3 H3 H3 H3 H3 (LADIES) SALES AREA ACT-1 001 (LAD. DIV) SALES AREA ACT-1 001 (KIDS) SALES AREA ACT-1 001 ROOM #1 STOCK PT-1 017 LOUNGE ACT-1 014 WINDOW #4 POSTER PT-1 008 WINDOW #1 POSTER PT-1 002 WINDOW OPEN PT-1 003 WINDOW #2 POSTER PT-1 004 WINDOW DISPLAY PT-1 005 ENTRY PT-1 006 WINDOW #3 POSTER PT-1 007 ROOM ADMIN PT-1 009 MTG. RM. SECURITY ACT-1 010 HALLWAY ACT-1 012 CLOSET JANITOR'S PT-1 011 TOILET RM. WOMEN'S H/C PT-1 013 TOILET RM. MEN'S H/C PT-1 015 ROOM LAN N/A 016 ROOM ELECTRICAL N/A 018 AREA #1 FITTING RM. PT-1 019 ROOM #2 STOCK PT-1 020 AREA #2 FITTIN RM. PT-1 021 ROOM #3 STOCK PT-1 022 WINDOW #5 POSTER PT-1 023 (MENS) SALES AREA ACT-1 001 NIGHTBOX REMOTE PT-1 024 (PORTAL) PT-3 (PORTAL) PT-3 (PORTAL) PT-3 (PORTAL) PT-3 (PORTAL) PT-3 G G G GGG EXTERIOR H3 H3 H3 H3 H3 H3 GGG G G G G G G A B C D E C.3 12345678910 EXTERIOR EXTERIOR EXTERIOR EXTERIOR MALL SERVICE CORRIDOR MALL SERVICE CORRIDOR (LIGHT COVE) PT-1 (LIGHT COVE) PT-1 (LIGHT COVE) PT-1 (LIGHT COVE) PT-1 (LIGHT COVE) PT-1 (LIGHT COVE) PT-1 (LIGHT COVE) PT-1 (LIGHT COVE) PT-1 NOTE: 1. SEE LIGHTING SCHEDULE FOR LIGHTING LEGEND. 2. G.C. TO PROVIDE BLOCKING ABOVE CEILING OR ON WALL, AS REQUIRED, FOR ALL CEILING / WALL MOUNTED SPECIALTY LIGHTING FIXTURES & SIGNS, U.O.N. SYM. DESCRIPTION STANDARD WHITE CEILINGS: ARMSTRONG DUNE 2'x2'x5/8" #1772 GREY CEILINGS: ARMSTRONG DUNE 2'x2'x5/8" #1772 MR87392 GYP. BD. CEILING; REFER TO FINISH PLAN & CEILING DETAILS HATCHED AREA DENOTES FRAMED SOFFIT / CURTAIN WALL CONSTRUCTION; REFER TO CEILING DETAILS CEILING TAG CEILING SECTION/DETAIL TAG - SEE CEILING DETAILS SHEET REFLECTED CEILING PLAN TAG NOTEX CLG. HT. FINISH NO. DESCRIPTION TENANT LEASE LINE. PROJECT TEAM TO VERIFY IN FIELD. STOREFRONT LEASE LINE AT POP-OUT. PROJECT TEAM TO VERIFY IN FIELD. HATCHED LIGHT INDICATES EMERGENCY FUNCTION. NL TO INDICATE NIGHT-LIGHT FUNCTION. REFER TO ELECTRICAL SHTS. FOR MORE INFORMATION. CONCEALED EMERGENCY LIGHT HOUSING TO BE PRE-FINISHED WITH PAINT TO MATCH ADJACENT CEILING COLOR. TYP. INTERNALLY ILLUMINATED STOREFRONT SIGN BY SIGN VENDOR. G.C. TO COORDINATE WITH STOREFRONT SHTS AND SIGN SHOP DRAWINGS FOR PROPER MOUNTING IF PENDANT HUNG FROM CEILING/SOFFIT ABOVE, FLUSH OR RECESSED 'PUSH-THRU'. G.C. TO PROVIDE POWER AND BLOCKING PRIOR TO VENDOR INSTALLATION. REFER TO STOREFRONT SHTS. AND SIGNAGE SHOP DRAWINGS FOR MORE INFORMATION. INTERNALLY ILLUMINATED STOREFRONT BLADE SIGN BY SIGN VENDOR. G.C. TO PROVIDE POWER AND BLOCKING PRIOR TO VENDOR INSTALLATION. REFER TO STOREFRONT SHTS. AND SIGNAGE SHOP DRAWINGS FOR MORE INFORMATION. TYP., SEE CONSTRUCTION PLAN FOR LOCATIONS. 1 2 3 4 5 6 ACT CEILING EXPANSION JOINT. REFER TO SHT A-720 FOR MORE INFORMATION. LIGHT BOX FIXTURE SURFACED MOUNTED ON WALL PROVIDED BY H&M AND INSTALLED BY G.C., CENTERED BEHIND CASHPOINTS ABOVE CASHWRAP ON STOREFRONT FACADE OR INTERIOR PARTITION (SEE PLAN FOR EXACT LOCATIONS). SEE SIGNAGE DETAIL SHT. FOR MORE INFORMATION. G.C. TO PROVIDE AND INSTALL IN-WALL F.R.T. PLYWOOD BLOCKING AS REQUIRED. G.C. SHALL SUPPLY AND INSTALL ALL ELECTRICAL REQUIREMENTS FOR LIGHT BOX AND ASSOCIATED SIGNAGE. COORDINATE HEIGHT OF J-BOX WITH LIGHT BOX SPECIFICATIONS. REFER TO ELECTRICAL DRAWINGS, H&M PROJECT MANAGER, AND H&M PROVIDED "IPS DRAWINGS, CATALOGUES, AND CONSTRUCTION INFORMATION." FOR MORE INFORMATION. ILLUMINATED NAVIGATION SIGN BY H&M, (CENTERED ABOVE PORTAL OPENING OR CEILING MOUNTED - WHERE APPLICABLE). INSTALLED BY E.C. G.C. TO PROVIDE POWER AND BLOCKING. REFER TO DETAIL ON A-322 & SIGNAGE SHOP DRAWINGS FOR MORE INFORMATION. LED STORE GUIDE SURFACE MTD. ON WALL PROVIDED BY H&M AND INSTALLED BY G.C. G.C. TO PROVIDE AND INSTALL IN-WALL F.R.T. PLYWOOD BLOCKING AS REQUIRED. G.C. SHALL SUPPLY AND INSTALL ALL ELECTRICAL REQUIREMENTS FOR STORE GUIDE. COORDINATE HEIGHT OF J-BOX WITH STORE GUIDE SPECIFICATIONS. REFER TO SHT. A-551, 'E' DRAWINGS, H&M PROJECT MANAGER, AND H&M PROVIDED "IPS DRAWINGS, CATALOGUES, AND CONSTRUCTION INFO." FOR MORE INFO. 7 8 9 10 LIGHT COVE, AT POSTER WINDOWS ONLY. REFER TO RCP & STOREFRONT SECTION SHTS. FOR MORE INFO. LINEAR LED LIGHTS AT POSTER WINDOWS ONLY. REFER TO STOREFRONT SECTIONS SHTS. FOR PLACEMENT REFER TO STOREFRONT SECTION SHTS. FOR POSITION OF TRACK LIGHTS / LED LINEAR LIGHTING IN STOREFRONT OPEN, DISPLAY AND POSTER WINDOWS. CLIPS FOR TRACK LIGHTING EVERY 48" SCREWED DIRECTLY TO 'T' BAR. G.C. TO TIGHTEN CLIPS PRIOR TO STORE OPENING G.C. TO COORDINATE SIZE AND LOCATION WHERE ACCESS PANELS ARE REQUIRED. NOTIFY ARCHITECT, AND CONFIRM FINAL QUANTITY AND LOCATIONS OF ALL ACCESS PANELS SHOWN ON SITE. MANUFACTURER: ACUDOR OR EQUAL. CONTACT: BARBARA CURRAW ACUDOR PRODUCTS INC. 80 LITTLE FALLS RD. FAIRFIELD, NJ 07004 973-575-5120 BCURRAW@ACUDOR.COM HEIGHT OF FITTING ROOM ENTRY PORTALS TO ALIGN WITH TOP OF FITTING ROOM SPECIAL PANELS. G.C. MUST OBTAIN AN ACTUAL FITTING ROOM SPECIAL PANEL TO THE JOB SITE IN ORDER TO INSTALL HEADER ACCURATELY AT FITTING ROOM PORTAL FROM SALES AREA. G.C. TO PROVIDE BLOCKING IN CEILING FOR FULL HEIGHT FRAMEWORK FIXTURES AND CEILING MOUNTED LIT NAVIGATION SIGNS. SEE DETAILS ON A-720 FOR MORE INFORMATION. 11 12 13 14 15 16 17 1. GC TO COORDINATE ALL NECESSARY WALL OR CEILING ACCESS PANELS WITH LAYOUT (USE INTEXFORMS ACCESS PANELS, RADIAL CORNERS, 'GRFG'). PROVIDE ACCESS PANEL LAYOUT TO ARCHITECT AND ENGINEER FOR APPROVAL. REFER TO MEP SHEETS FOR MORE INFORMATION. CONFIRM LOCATIONS WITH LANDLORD'S REP. GC TO INCLUDE IN BID QTY. (6) MIN. 24"X24" CONCEALED TYPE IN GYP. BD. CEILINGS. 2. GC TO CLEAN ALL INSTALLED LIGHTING FIXTURES PRIOR TO TURN OVER AS REQUIRED. 3. REFER TO MEP SHEETS FOR FIRE PROTECTION DIRECTION. ALL FIRE PROTECTION SPRINKLER HEADS ARE TO BE PLACED AS TO NOT INTERFERE WITH LIGHTING, HVAC AND STORE FIXTURING COMPONENTS. 4. CEILING GRID IN BACK OF HOUSE SUPPORT OFFICES ARE TO BE HUNG WITH #12 HANGER WIRES (48"O.C.) WITH ADDITIONAL WIRES AT ALL FOUR CORNERS OF ALL LIGHT FIXTURES, DIFFUSERS, ETC. 5. ALL SUSPENDED COMPONENTS ARE TO BE SUSPENDED FROM TOP CHORD OF EXISTING JOISTS. DO NOT ATTACH SUSPENSION ATTACHMENTS FROM METAL ROOF DECKING (IN CONCRETE DECKING USE APPROVED CONCRETE FASTENERS). 6. SUSPENDED ACOUSTICAL CEILING SYSTEM IS TO BE IN COMPLIANCE WITH THE APPLICABLE CODE AND ASTM C 635 AND ASTM C 636. 7. ELECTRICAL CONTRACTOR TO MAKE ALL FINAL CONNECTIONS TO MILLWORK / FIXTURES / CASHWRAPS IN FIELD. 8. COORDINATE LIGHTING FIXTURE LOCATIONS AND DIFFUSER LOCATIONS WITH OTHER CEILING COMPONENTS WITH LIGHTING BEING THE DECIDING COMPONENT. 9. SPEAKERS PROVIDED AND INSTALLED BY OTHERS. GENERAL CONTRACTOR TO PROVIDE AND INSTALL: CONDUITS, J-BOXES FOR DJ JACK(S), VOLUME CONTROLS, PULL ALL WIRES AND SPEAKER CANS AS SHOWN ON DRAWINGS. OWNER'S VENDOR TO INSTALL FINAL HOOK UP OF SPEAKERS AND EQUIPMENT. SPEAKER BACK BOXES SUPPLIED BY OWNER'S VENDOR AND INSTALLED BY GC. 10. CONTRACTOR TO PROVIDE COORDINATION DRAWING FOR ALL TRADES INCLUDING SPRINKLER, MECHANICAL, ELECTRICAL, FIRE ALARM, SECURITY, ACCESS PANEL & ETC. IN CEILING FOR ARCHITECT'S APPROVAL PRIOR TO CONSTRUCTION. UNCOORDINATED CONDITIONS THAT ARE CONTRARY TO THE DESIGN INTENT ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO RESOLVE. 11. IN THE CASE OF DISCREPANCY BETWEEN THE ARCHITECT'S AND/OR ENGINEER'S DRAWINGS, THE MORE STRINGENT, HIGHER QUANTITY, OR HIGHER QUALITY SHALL PREVAIL. ARCHITECT IS TO BE ADVISED OF ALL DISCREPANCIES PRIOR TO START OF CONSTRUCTION. 12. ALL DIMENSIONS TO BE COORDINATED IN THE FIELD WITH H&M AND ARE SUBJECT TO EXISTING CONDITIONS DIMENSIONS MARKED AS EQUAL (EQ.) APPLY ONLY WITHIN A GIVEN STRING OF DIMENSIONS UNLESS OTHERWISE MARKED. 13. ALL SPEAKERS MUST BE FLUSH MOUNT AND FINISHED TO MATCH ADJACENT CEILING FINISH. GC TO COORDINATE WITH SPEAKER CONTRACTOR TO CENTER SPEAKERS BETWEEN LIGHT FIXTURES (ALONG STRAIGHT OR DIAGONAL LINE) AS SHOWN ON PLAN WHEREVER POSSIBLE. 14. ALL CONDUITS TO BE CONCEALED UNLESS OTHERWISE NOTED. LAYOUT FOR ANY EXPOSED ELECTRICAL CONDUIT TO BE APPROVED BY H&M IN FIELD PRIOR TO INSTALLATION. 15. ALL SPRINKLER HEADS TO BE FLUSH MOUNT WITH COVER PLATE AT ALL FINISHED CEILINGS, CENTERED ON LIGHT FIXTURES LAYOUT OR CEILING TILES AS APPLICABLE. 16. REFER TO FINISH FLOOR PLANS FOR FINISH NOTES. GC TO VERIFY ALL CEILING FINISHES WITH H&M PRIOR TO CONSTRUCTION. ALL CEILING ELEMENTS AND DEVICES (LIGHT FIXTURE HOUSINGS AND TRIMS, SPEAKERS, SPRINKLER CAPS, GRILLES, DIFFUSERS, ETC.) SHALL BE PRE-FINISHED OR BE PAINTED OR COLORED THE SAME COLOR AS THE ADJACENT CEILING PAINT. ALL PAINTING SHALL BE COMPLETED OFFSITE. GC TO COORDINATE WITH VENDORS AND SUBCONTRACTORS FOR CORRECT FINISHES AND LONG LEAD ITEMS. 17. ALL VERTICAL ELEMENTS OF SOFFITS TO BE PAINTED TO MATCH ADJACENT COPLANAR WALL PAINT. 18. SPRAY ALL VISIBLE AREA ABOVE GYP. BD. & ACT CEILING BLACK. 19. GC TO PLUG ALL LIGHT LEAKS IN DISPLAY WALLS/FIXTURES. 20. ALL TRIMLESS LIGHTS TO RECEIVE TEARAWAY BEAD. TRIMLESS LIGHTS TO HAVE SMOOTH, CLEAN EDGES AND ARE TO BE INSTALLED FLUSH WITH ADJACENT CEILING. 21. LIGHT GRID TAKES PRECEDENCE WHEN INSTALLING ALL CEILING ELEMENTS. IF ANY INTERFERENCES OCCUR BETWEEN LIGHT GRID, CEILING DIFFUSERS, SPEAKERS, ETC. THE LIGHT GRID SHALL NOT MOVE. GC SHALL NOTIFY ARCHITECT OF DISCREPANCY. ALL CEILING ELEMENTS TO ALIGN WITH GRID. 22. REFER TO LIGHTING FIXTURE SCHEDULE AND NOTES ON ELECTRICAL DRAWINGS FOR FIXTURE SUPPLY/INSTALLATION RESPONSIBILITIES AND EMERGENCY LIGHTING LOCATIONS. 23. ALL EXPOSED STRUCTURAL STEEL TO BE FIRE-PROOFED PER LOCAL CODES. GC TO REPAIR ALL EXISTING FIREPROOFING. 24. GC TO ASSUME CEILING TILES TO BE CENTERED IN ROOM IN BOTH DIRECTIONS, U.N.O. 25. USG GYP. BD. DROPPED CEILING HAS 16" GRID. COORDINATE WITH RECESSED LIGHT FIXTURE LOCATIONS PER INDIVIDUAL AREAS. 26. GC TO PROVIDE BLOCKING ABOVE CEILING OR ON THE WALL, AS REQUIRED, FOR ALL CEILING MOUNTED SPECIALTY LIGHTING FIXTURES AND SIGNS, UNLESS OTHERWISE NOTED. 27. ELECTRICIAN TO MARK ALL SWITCH, OUTLET, SPEAKER, CAMERA AND SECURITY LOCATIONS IN FIELD AND WALK THROUGH WITH H&M BEFORE INSTALLATION - ALL LOCATIONS ARE SUBJECT TO H&M APPROVAL. 28. SPEAKER VENDOR TO PROVIDE WIRE AND E.C. TO PULL AND INSTALL WIRE. WIRE IS TO BE PLENUM RATED AND DOES NOT NEED TO BE INSTALLED IN CONDUIT UNLESS LOCAL JURISDICTION REQUIRES. IF REQUIRED, E.C. IS TO INSTALL CONDUIT. 29. TRACK AND CONNECTORS MUST BE PRE-FINISHED WITH COLOR TO MATCH CEILING. 30. U.S.G. GYP. BD. DROPPED CEILING HAS 16" GRID. COORDINATE GRID WITH RECESSED LIGHT FIXTURE LOCATIONS PER INDIVIDUAL AREAS. 31. PORTALS TO BE 9'-6" A.F.F. AND PAINTED PT-1. FITTING ROOM PORTALS (PAINTED PT-1) TO BE COORDINATED WITH FITTING ROOM "WP-1" PANEL HEIGHTS . FOR CEILING HEIGHTS LOWER THAN 8'-3" PORTALS SHALL BE IN LINE WITH TOP OF WARDROBE. USE THESE GENERAL GUIDELINES UNLESS OTHERWISE NOTED. 32. GC TO PROVIDE TEAR AWAY BEAD AT ALL TRIMLESS FIXTURES. ACT-1 ACT-2 GENERAL CEILING NOTES CEILING SYMBOL LEGEND REFLECTED CEILING KEY NOTES EQ.EQ. EQ.EQ. EQ.EQ. EQ.EQ. EQ.EQ. EQ.EQ. EQ.EQ. EQ.EQ. EQ.EQ. EQ.EQ. EQ.EQ. EQ.EQ. CL CL CL CLCLCL CL CL CL CL CLCL 17 7'-0" 7'-0" CL CL CL 6'-0"EQ.EQ. CL CL 3'-77 8" 8'-0"3'-77 8" EQ. 6'-0" 6'-0" EQ. 5'-11" 6'-0" 6'-0" 6'-0" 6'-0" 5'-117 8" 5'-41 2"5'-93 8" EQ. EQ. 1'-93 4"6'-0"6'-0"6'-0"6'-0" EQ. EQ. EQ.EQ. 6'-0"6'-0"6'-0"EQ.EQ. EQ.EQ. EQ.EQ. EQ. EQ. EQ.EQ. EQ.EQ. 2'-11" 4'-0" TYP. 2'-53 4"4'-65 8" 1'-77 8"2'-0" 6'-93 8"6'-11" 5'-73 4"6'-0"6'-0" EQ.EQ. 5'-25 8" EQ.EQ. 2'-15 8" 4'-0" TYP. 2'-11 4" 1'-111 8"2'-0" 1 1 1 1 1 1 1 1 1 1 1 1 1 TYP. 4 3 14 TYP. 4 3 14 TYP. 4 3 14 TYP. 4 3 14 3 3 3 3 15 4 3 15 4 3 4 15 17 17 17 17 17 3 9 9 9 9 9 9 10 5 5 6 6 16 16 8 8 8 11 11 11 11 11 12 11 12 12 12 12 12 12 1213141314 TYP. 6 TYP. 6 TYP. 6 TYP. 6 TYP. 1 TYP. 1 TYP. 1 TYP. 1 TYP. 9 TYP. 9 TYP. 1 TYP. 1 TYP. 2 TYP. 2 EQ.EQ. EQ. EQ. EQ. EQ. EQ.EQ. EQ.EQ. FULL TILE FULL TILE FULL TILE FULL TILE EQ.EQ. EQ.EQ.EQ.EQ. EQ. EQ. 3'-13 8" TYP. 3'-81 8" TYP. 3'-53 8" TYP. 3'-53 8" TYP. 1'-07 8" 43 4" 1'-27 8" 51 8" 31 4" 15 15 15 15 15 15 15 1515 15 15 2 EQ. EQ. 5 EQ. 19'-75 8" EQ. EQ.3'-6"EQ. REVISION: SHEET TITLE: SPACE NO.: ARCH PROJECT NO.: SCALE: DRAWN BY: REV. NO: SHEET NO: PRODUCT SEASON: 2018 US667-BLUE BRANSONLANDING BUILDING1000 SPACENOS.1003-1013 100BRANSONLANDINGBLVD BRANSON,MOZIP65616 AS NOTED 2018 2187-17 ISSUE DATE: 1003-1013 D.O.B. NO: 12.18.17 CLIENT/LANDLORD REVIEW REFLECTED CEILING PLAN 1 SCALE: 1/8" = 1'-0" REFLECTED CEILING PLAN (REMOTE NIGHTBOX) 2 SCALE: 1/8" = 1'-0" NORTH RECESSED LIGHTS DIMS. - (TYP.) 3 SCALE: N.T.S. (FOR REFERENCE AND GENERAL INFORMATION ONLY) MH A-310 REFLECTED CEILING PLANS NOT USED NOT USED