1. NON-COMPACTED EARTH
12
12
...ARTTIC VENTILLATION ON
ROOF DECKING, 1 HOUR ASSEMBLY
PER CHAPTER 3.
MAINTAIN 3-1/2" AIR SPACE FOR
VENTILATION.
(2) 2x4 TOP PLATE
3/4" WOOD FASCIA
SOFFIT BOARD,
EXTERIOR WALL SYSTEM
1/2" OSB NAILED 6" ON EDGES
12" FIELD NAILING.
PER CHAPTER 6, 2006 IRC.
SLAB ON GRADE,
1/2" V-GROOVE CEDAR PANEL
POST TENSIONED CONCRETE,
SEE STRUCTURAL DWGS
COMPACTED EARTH
SEE FINISH SCHEDULE
SEE FINISH SCHEDULE
WALL BASE,
FLOOR FINISH,
2x4 P.T. SILL PLATE SET IN FOAM
SILL SEALER - SEE STRUCTURAL
FOR PLATE ANCHORS.
DWELLING
R-19 BATT INSULATION
2x4 STUDS @ 16" O.C.
5/8" GYP. BO. TYPE x
1 HOUR RATED
1" FOAM BOARD.
EXTERIOR SIDING.
ATTIC
GYP. BD. CLIPS OR
BLOCKING @ CONTRACTOR'S
OPTION (TYP.)
FLOOR,
LOFT
FINISHED GRADE,
SLOPE TO DRAIN
8"
TYP.
11/2"11/2"
1 1/2"
2x10, 16" O.C.
AGGREGATE, BASE COURSE
RAFTER
MAINTAIN 3-1/2"
1'-0"
TYP.1 HOUR RATED
AIR SPACE
3/4" PLYWOOD
AWAY FROM
BUILDING
AWAY FROM
SCALE: 1/2" = 1'- 0"
SECTION FOR BUILDING PERMIT EXHIBIT
T. MORPHIS
10 / 17 / 15
STUDIO HOME