TELKOMNIKA, Vol.15, No.2, June 2017, pp. 888~894
ISSN: 1693-6930, accredited A by DIKTI, Decree No: 58/DIKTI/Kep/2013
DOI: 10.12928/TELKOMNIKA.v15i2.6141  888
Received February 7, 2017; Revised April 28, 2017; Accepted May 10, 2017
Harmful Gases Profiling in Meru Menora Tunnel using
SICK Sensor
A. N. Baharun
1
, N. A. Murad
2
, N. N. N. A. Malik
3
1
Persada PLUS, Persimpangan Bertingkat Subang, KM15, Lebuhraya Baru Lembah Klang, 47301
Petaling Jaya Selangor
2,3
Advanced RF and Microwave Research Group (ARFMRG), Communication Engineering Department,
Faculty of Electrical Engineering, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor
Abstract
This paper discusses the study on the measured harmful gases due to traffic emission in the
Meru Menora Tunnel, a Malaysia highway tunnel. The hazardous gasses data would help in promoting
essential ventilation system inside the tunnel for the health and safety of the users. The emission gasses
concentration reading is divided into two main components comprise of Nitrogen Dioxide (NO2), and
Carbon Monoxide (CO). Other than that, the visibility also been measured by using SICK sensor. The
measurement has been done during normal, festive and school holiday seasons. Festive season shows
the highest number of traffic and thus giving the worst air quality. Ventilation fan system can be activated
based on the concentration level of gases and visibility in the tunnel.
Keywords: Harmful gas, SCADA, Tunnel, SICK sensor, in tunnel ventilation
Copyright © 2017 Universitas Ahmad Dahlan. All rights reserved.
1. Introduction
The increasing number of vehicles on the road urged the enhancement of traffic flow
and safety especially in heavy traffic highway line. The monitoring system on Meru Menora
Tunnel infrastructure due to mountainous landscape on the Malaysia highway line is vital. Diesel
emissions spread hazardous gasses that could be harmful to the users. Thus efficient
ventilation system is crucial at peak traffic fleet inside the tunnel. In a tunnel, harmful gases can
accumulate and became hazardous to the tunnel user and maintenance working staff. Gasses
in diesel smoke comprises of Nitrogen Oxides (NOx), Carbon Monoxide (CO), Carbon Dioxide
(CO2), Sulfur Dioxide (SO2) and other oxygenated hydrocarbons such as acetaldehyde and
formaldehyde [1]. A high concentration can be hazardous particularly in certain circumstances
involving traffic collisions where smoke from a small fire can reduce the visibility with possibility
of explosion due to the accumulate gasses [2].Therefore, an air ventilation system is needed to
reduce the gases concentration in the tunnel to ensure the health and safety of the user. A
monitoring system is essential to monitor and determine the gas concentration and visibility in
the tunnel. This paper focuses on the harmful gases monitoring inside the Meru Menora Tunnel.
The tunnel is located in Northern Malaysia with 861 meter long. It is run in 2 separated tubes;
one for north-going traffic and one for south-going traffic, each with two lanes. Figure 1 shows
the layout of the Meru Menora Tunnel.
Figure 1. Meru Menora Tunnel layout studied section.
TELKOMNIKA ISSN: 1693-6930 
Harmful Gases Profiling in Meru Menora Tunnel using SICK Sensor (A. N. Baharun)
889
More than ten momentum ventilation fans are operated at 11kW in each tube to assist
the slow traffic or in case of fire. In the tunnel, 15 fire hydrants is provided and equied with 14
ventilation shafts for exhausting polluted air through ventilation fan that is located along north-
going tunnel.
2. Data Collection
Monitoring the condition inside the tunnel is vital to ensure the smooth traffic as well as
maintaining the safety of the users. For time being the monitoring system is not fully automated.
The enhancement of the system can facilitate real time control by the authorities remotely as
well as on site. Automated monitoring system can be realized using Supervisory Control and
Data Acquisition (SCADA) system. It is defined as a system that operates to monitor, control
and analysis the process that generate from various remote devices [3-8]. Programmable Logic
Controller (PLC) or Remote Terminal Unit (RTU) acts as data collector and relay the information
to the master station for the operator to perform remote control tasks [9-11]. The system
required monitoring data and process for further action.
In particular, the harmful gases concentration is the data monitored through the Human
Machine Interface (HMI). The data is collected by using SICK sensor that measure the
concentration of Nitrogen Dioxide (NO2), Carbon Monoxide (CO) and air visibility. The collected
data is used to trigger the ventilation fan to operate and reduce the gasses concentration. An
automated ventilation system can minimize the energy consumption with selected fan for
ventilations. The gases concentration is determined by using Differential Optical Absorption
Spectroscopy (DOAS) where the technique used Ultra Violet (UV) and visible region to analyze
broadband spectra transmitted through a long open path [12]. In [12], Beer-Lamberts Law
proposed that:
( , , )= 0( ) − ( , , ) (1)
where
I( ) = intensities
I0( ) = unattended reference intensities
L = path length in cm,
( ) = the wavelength, pressure, temperature dependent absorption cross sections
[cm2.molecule-1]
n = denoted as the number density of the species [molecules/cm3].
Equation (2) is proposed by adding Rayleigh and Mie scattering to (1) as both scattering
contribute to the radiation extinction, where Equation (2) is as follows:
( , , )= 0( ). {Σ[− ( , , )× − ( )− ( )]× }. ( ) (2)
where ( ) is the Rayleigh extinction coefficient product of Rayleigh cross section,
R( ) and the number density of air, nair. Meanwhile, ( ) is Mie extinction coefficient that
correspond to M( )nair. ( ) is attenuation of the instrument optics while denote as
atmospheric or gas species.
0( )is determined in open atmosphere and the total cross section ( ) as follow:
= + ′ (3)
where is the one slowly varying with wavelength and ′ is the one rapidly varying.
After substitute Equation (3) into Equation (2), Equation (4) is produced as:
( , , )= 0( ). [−Σ ′( , , )× × ] {Σ−[ ( , , )× + ( )+ ( )]× }. ( ) (4)
Intensity in the absence of differential absorption 0′can be estimated using Polynomial
fit, Digital smoothing or Fourier transform. Therefore, Equation (4) will turn toEquation (5):
( , , )= 0′( ) [−Σ ′( , , )× × ] (5)
 ISSN: 1693-6930
TELKOMNIKA Vol. 15, No. 2, June 2017 : 888 – 894
890
The process of SICK sensor data capturing begin with the laser to shot from sender and
receiver. Then the sensor at receiver analyzes the reading and sent the data to converter. Fiber
converter at substation panel converts the data and sent it through fiber network straight to
Ethernet converter in server room. Next, data is sent through the Ethernet to the SCADA
system. From SCADA, fan speed is determined based on the pre-set and the signal is sent to
panel in server room. The signal is converted to fiber signal and is sent by using the fiber
network to the VSD. After receive the signal, VSD runs the fan at its desired speed and
response signal back to SCADA system. Response from VSD is read by SCADA and view new
speed of the fan.
Figure 2 presents the configuration of SCADA system test for the sensor. Firstly,
VICOTEX sensor sender emit infrared signal to receiver with the right alignment aim to achieve
maximum signal strengths with the minimum possible gain setting Then, receiver sensor
analyzes the reading and sent it to PLC in current 4-20mA format. After signal is received, the
PLC processes the data and sent TCP/IP signal to SCADA system through Local Area Network
(LAN). SCADA software will recognize the signal and display on the HMI.
Figure 3 shows the graph conversion from current signal to gas concentration. The
graph is constructed by measuring the current signal sent by the sensor and the concentration
display on the HMI. As example, when the signal input is 20 mA, the concentration of the gas
will be 27648 m. Meanwhile, the minimum current of 4 mA will produce 0 m gas. The current
value is analog value from sensor to the PLC.
Figure 2. SCADA system test setup
Figure 3. Current signal to gas
concentration graph conversion
Table 1 show the value of m produces when we aly the graph on Fig. 4 which is as a
reference of connection between Analogue signal (mA) and Output Software. The test kit value
shall verify the system functionality by using Tunnel Sensor Control Unit (VICOTEX/TSCU)
Utility Software to ensure correct issue and receipt of commands as well as response of the
command through status monitoring using SCADA HMI. The value of gases in the Meru Menora
Tunnel will simulate analog output using VICONOX/TSCU Utility software to sensor and
compare to the reading show in SCADA HMI.
Table 1. Value from test kit
Simulation (mA) 4 % 12 % 20 %
Visibility (m) 1.1 1.1% 55.3 55.3% 100 100%
NO2 (m) 0.2 0.05% 198.6 49% 399.8 100%
Analogue (4-20mA)
SCADA Simulator
(Installed on laptop)
TELKOMNIKA ISSN: 1693-6930 
Harmful Gases Profiling in Meru Menora Tunnel using SICK Sensor (A. N. Baharun)
891
CO (m) 43 1.73% 1296.5 52.25% 2481.2 100%
The arrangement of the ventilation fan is shown in Figure 4. Table 2 shows the level set
of ventilation fan according to several set points according to the minimum standard value. The
levels are divided into 5. Level 0 is the minimum level which operates with 4 fans at 30 Hz
frequency speed. Meanwhile, Level 4 mode operates as maximum mode with 12 fans switch on
at 45 frequency speed.
Figure 4. Ventilation fan location in the Meru Menora Tunnel
Table 2. Operation level of ventilation fan
Level Set Points
Visibility (m) CO (m) NO2 (m) Fan
Frequency (Hz)
No. of Fans
Active
0 < 2.0 < 20 < 0.5 30 4
1 2.5 20 0.5 35 4
2 5.0 40 1.0 35 7
3 7.5 60 1.5 40 7
4 10.0 80 2.5 45 12
3. Results and Analysis
Table 3 shows the calculated number of vehicles in a week for Normal, Festive and
School Holiday season respectively. The Festive season recorded the highest total vehicles
followed by School Holiday, while Normal shows the lowest number.
At peak Festive season, the air quality is expected to be the worst as the number of
vehicles is more than usual. The air quality in term of visibility and gasses concentration is
shown in Figure 5. The most harmful NO2 gas shows an extremely low reading while visibility
reading is at 3 ± 1 m. The CO gas is average at 5 m, however increased by 10 m in the
afternoon. Thus, 4 fans at the speed of 35 Hz is activated for ventilation purposes. The
ventilation is hoped to reduce the gasses concentration, thus reducing the risk of fire, explosion,
and gas poisoning as well as increasing the visibility.
Figure 6 shows the comparison of visibility during Normal, Festive and School Holiday
season. The visibility in Normal condition is less than 0.5 m since the vehicles flow through the
Meru Menora Tunnel is less compared to School Holiday season. The traffic is increased during
School holiday in both direction, North and South-going. Thus, the visibility reading increased
around 1.5 m. Meanwhile, in Festive season, the heavy traffic increased the reading up to 2 m.
 ISSN: 1693-6930
TELKOMNIKA Vol. 15, No. 2, June 2017 : 888 – 894
892
Table 3. Total vehicles for Normal, Festive and School Holiday Season respectively
Day SEASON
Normal Festive School Holiday
1 20057 22293 21601
2 22041 27022 25418
3 21685 29516 24490
4 19179 28661 20416
5 19076 34758 21685
6 20494 36306 21506
7 19214 25863 22315
TOTAL 141746 204419 157431
Figure 5. Air Qualities for Festive Season
Figure 6. Visibility comparison during Festive, Holiday and Normal season
Nitrogen Dioxide (NO2) gas reading is shown in Figure 7. The reading is less than 0.002
m for both Normal and School Holiday season. For Festive season, it can be observed that the
NO2 gas reading is increased up to 0.016 m due to the heavy traffic. As the time flow, the
vehicle flow also increase, thus, the harmful gas also increase and reduce the gas concentration
helps the tunnel user drive safely.
Comparison of Carbon Monoxide (CO) gas concentration is illustrated in Figure 8. In
Normal season, the reading is less than 4 m meanwhile in School Holiday; the reading shows
that the CO gas concentration is less than 6 m. However, there is slightly increment between
5-7 am which recorded 11 m reading. In Festive season, the gas concentration is highest at 16
m measured at 4 pm and recorded 15 m at 5 pm. The reading shows that the ventilation fan
helps to reduce the gas concentration.
TELKOMNIKA ISSN: 1693-6930 
Harmful Gases Profiling in Meru Menora Tunnel using SICK Sensor (A. N. Baharun)
893
Figure 7. Nitrogen Dioxide (NO2) gas concentration reading comparison
Figure 8. Comparison of Carbon Monoxide (CO) gas concentration reading.
Figure 9 presents the fan speed for Festive, Holiday and Normal season. The fan speed
is simulated based on Table 2 and input from measured visibility, NO2 and CO gas shows in
Figure 6, 7 and 8, respectively. In Figure 9, measured gas during festive season simulate varies
fan speed from 12 am to 9 am. As example, at 12 am, the fan speed is at 30 Hz and increase to
35 Hz when time increase to 1 am. Meanwhile, the fan speed from 3 to 6 am is nearly constant
about 35 Hz. Besides, from 9 am to 11 pm, the fan speed is constant a minimum 30 Hz. Holiday
and Normal season shows constant fan speed at 30 Hz. Based on the fan speed simulation, the
increase number of vehicles during Festive season increase the gas concentration. Thus,
increase the fan speed.
 ISSN: 1693-6930
TELKOMNIKA Vol. 15, No. 2, June 2017 : 888 – 894
894
Figure 9. Simulated fan speed of festive, holiday and normal season
4. Conclusion
The air quality inside the Meru Menora Tunnel in term of visibility, CO gas and NO2 gas
are measured and analysed to promote essential ventilation for health and safety purposes. The
ventilation fan system in Meru Menora Tunnel also discussed. The fan system will operate
depending on the gasses concentration level, thus not all fan are operated at one time. This will
encourage an efficient power consuming by selecting certain fan configuration at certain
frequency. Data on total vehicles shows that Festive season is highest compared to Normal
and School Holiday season. Besides, the fan speed also increases due to the increase of
vehicle during Festive season. Therefore, the gasses concentration is the highest during Festive
season compared to other season. It is expected to have a better ventilation system during
Festive season when the traffic is high.
Acknowledgements
The authors would like to thank the Research Management Centre (RMC), School of
Postgraduate (SPS), Communication Engineering Department (COMM) Universiti Teknologi
Malaysia (UTM) and all members of Advanced Microwave Lab P18 FKE-UTM for giving
motivation, knowledge sharing and suort of the research under grant no 10H04.
References
[1] S Sanxiang, Z Yunxia. Monitoring of Harmful Gas for Yangbajing 1# Tunnel in High Altitude Plateau.
Measuring Technology and Mechatronics Automation (ICMTMA). 2014 Sixth International Conference
on. 2014: 410-412.
[2] XC Jiao. The road tunnel fire detection of multi-parameters based on BP neural network. Informatics in
Control, Automation and Robotics (CAR), 2nd International Asia Conference on. 2010; 246-249.
[3] A Daneels, W Salter. What is SCADA?. International Conference on Accelerator and Large
Experimental Physics Control Systems. 1999.
[4] Boyer, Stuart A. SCADA Supervisory Control and Data Acquisition. USA: ISA -International Society of
Automation. 2010; 179. ISBN 978-1-936007-09-7.
[5] Xie Lu. Supervisory Control and Data Acquisition System Design for CO2 Enhanced Oil Recovery.
Electrical and Computer Sciences. University of California. 2014.
[6] Boys, Walt. Back to Basics: SCADA. Automation TV: Control Global-Control Design. 2009.
[7] M Kover-Dorco. SCADA system creation by using java alications and PLC. Control Conference (ICCC).
2014 15th International Carpathian. 2014: 264-267.
[8] M Avhad, V Divekar, H Golatkar, S Joshi. Microcontroller based automation system using industry
standard SCADA. India Conference (INDICON), 2013 Annual IEEE. 2013: 1-6.
[9] M Ahmed, W Soo. Customized SCADA system for low voltage distribution automation system. in
Transmission & Distribution Conference & Exposition: Asia and Pacific. 2009: 1-4.
[10] M Sreejeth, M Singh, P Kumar, P Varshney, P Sachdeva. Implementation of supervisory control
system for PMSM drive. Power Electronics (IICPE), IEEE 5th India International Conference on, 2012:
1-6.
[11] MM Ahmed, W Soo. Supervisory control and data acquisition system (SCADA) based customized
remote terminal unit (RTU) for distribution automation system. Power and Energy Conference. PECon
2008. IEEE 2nd International. 2008: 1655-1660.

More Related Content

Similar to Harmful Gases Profiling in Meru Menora Tunnel using SICK Sensor

Flow Field Measurements in a Large Controlled Ventilated Room
Flow Field Measurements in a Large Controlled Ventilated RoomFlow Field Measurements in a Large Controlled Ventilated Room
Flow Field Measurements in a Large Controlled Ventilated RoomIRJET Journal
 
Design and implementation of a LoRa-based system for warning of forest fire
Design and implementation of a LoRa-based system for warning of forest fireDesign and implementation of a LoRa-based system for warning of forest fire
Design and implementation of a LoRa-based system for warning of forest fireTELKOMNIKA JOURNAL
 
Remote Monitoring System for Communication Base Based on Short Message
Remote Monitoring System for Communication Base Based on Short MessageRemote Monitoring System for Communication Base Based on Short Message
Remote Monitoring System for Communication Base Based on Short MessageNooria Sukmaningtyas
 
Development of Air Quality Monitoring System in Closed Environment
Development of Air Quality Monitoring System in Closed EnvironmentDevelopment of Air Quality Monitoring System in Closed Environment
Development of Air Quality Monitoring System in Closed EnvironmentTELKOMNIKA JOURNAL
 
Toxic Gas Detection-An Experiment with the Simulation Process
Toxic Gas Detection-An Experiment with the Simulation ProcessToxic Gas Detection-An Experiment with the Simulation Process
Toxic Gas Detection-An Experiment with the Simulation ProcessIRJET Journal
 
A performance of radio frequency and signal strength of LoRa with BME280 sensor
A performance of radio frequency and signal strength of LoRa with BME280 sensorA performance of radio frequency and signal strength of LoRa with BME280 sensor
A performance of radio frequency and signal strength of LoRa with BME280 sensorTELKOMNIKA JOURNAL
 
Prototype of multifunctional transmitter with Rejection of disturbances
Prototype of multifunctional transmitter with Rejection of disturbancesPrototype of multifunctional transmitter with Rejection of disturbances
Prototype of multifunctional transmitter with Rejection of disturbancesTELKOMNIKA JOURNAL
 
Smart Air Purifier with Air Quality Monitoring System
Smart Air Purifier with Air Quality Monitoring SystemSmart Air Purifier with Air Quality Monitoring System
Smart Air Purifier with Air Quality Monitoring SystemIRJET Journal
 
New system of chaotic signal generation based on coupling coefficients applie...
New system of chaotic signal generation based on coupling coefficients applie...New system of chaotic signal generation based on coupling coefficients applie...
New system of chaotic signal generation based on coupling coefficients applie...University of Malaya (UM)
 
Differential equation fault location algorithm with harmonic effects in power...
Differential equation fault location algorithm with harmonic effects in power...Differential equation fault location algorithm with harmonic effects in power...
Differential equation fault location algorithm with harmonic effects in power...TELKOMNIKA JOURNAL
 
Ultra-short Multi Soliton Generation for Application in Long Distance Commun...
Ultra-short Multi Soliton Generation for Application in Long Distance  Commun...Ultra-short Multi Soliton Generation for Application in Long Distance  Commun...
Ultra-short Multi Soliton Generation for Application in Long Distance Commun...University of Malaya (UM)
 
IRJET- Online Monitoring of Air Pollution using IoT
IRJET- Online Monitoring of Air Pollution using IoTIRJET- Online Monitoring of Air Pollution using IoT
IRJET- Online Monitoring of Air Pollution using IoTIRJET Journal
 
Nonlinear chaotic signals generation and transmission within an optical fiber...
Nonlinear chaotic signals generation and transmission within an optical fiber...Nonlinear chaotic signals generation and transmission within an optical fiber...
Nonlinear chaotic signals generation and transmission within an optical fiber...University of Malaya (UM)
 
Secured Transportation of Quantum Codes Using Integrated PANDA-Add/drop and T...
Secured Transportation of Quantum Codes Using Integrated PANDA-Add/drop and T...Secured Transportation of Quantum Codes Using Integrated PANDA-Add/drop and T...
Secured Transportation of Quantum Codes Using Integrated PANDA-Add/drop and T...University of Malaya (UM)
 
Secured transportation of quantum codes using integrated panda adddrop and td...
Secured transportation of quantum codes using integrated panda adddrop and td...Secured transportation of quantum codes using integrated panda adddrop and td...
Secured transportation of quantum codes using integrated panda adddrop and td...University of Malaya (UM)
 
Nonlinear Chaotic Signals Generation and Transmission within an Optical Fiber...
Nonlinear Chaotic Signals Generation and Transmission within an Optical Fiber...Nonlinear Chaotic Signals Generation and Transmission within an Optical Fiber...
Nonlinear Chaotic Signals Generation and Transmission within an Optical Fiber...University of Malaya (UM)
 

Similar to Harmful Gases Profiling in Meru Menora Tunnel using SICK Sensor (20)

Flow Field Measurements in a Large Controlled Ventilated Room
Flow Field Measurements in a Large Controlled Ventilated RoomFlow Field Measurements in a Large Controlled Ventilated Room
Flow Field Measurements in a Large Controlled Ventilated Room
 
http://ijtra.com/view/role-of-power-electronics-in-non-renewable-and-renewabl...
http://ijtra.com/view/role-of-power-electronics-in-non-renewable-and-renewabl...http://ijtra.com/view/role-of-power-electronics-in-non-renewable-and-renewabl...
http://ijtra.com/view/role-of-power-electronics-in-non-renewable-and-renewabl...
 
MEASUREMENT AND TRANSMISSION OF ATMOSPHERIC PARAMETERS USING RADIO FREQUENCY ...
MEASUREMENT AND TRANSMISSION OF ATMOSPHERIC PARAMETERS USING RADIO FREQUENCY ...MEASUREMENT AND TRANSMISSION OF ATMOSPHERIC PARAMETERS USING RADIO FREQUENCY ...
MEASUREMENT AND TRANSMISSION OF ATMOSPHERIC PARAMETERS USING RADIO FREQUENCY ...
 
Design and implementation of a LoRa-based system for warning of forest fire
Design and implementation of a LoRa-based system for warning of forest fireDesign and implementation of a LoRa-based system for warning of forest fire
Design and implementation of a LoRa-based system for warning of forest fire
 
GSM BASED GAS LEAKAGE DETECTION SYSTEM
GSM BASED GAS LEAKAGE DETECTION SYSTEMGSM BASED GAS LEAKAGE DETECTION SYSTEM
GSM BASED GAS LEAKAGE DETECTION SYSTEM
 
Remote Monitoring System for Communication Base Based on Short Message
Remote Monitoring System for Communication Base Based on Short MessageRemote Monitoring System for Communication Base Based on Short Message
Remote Monitoring System for Communication Base Based on Short Message
 
Development of Air Quality Monitoring System in Closed Environment
Development of Air Quality Monitoring System in Closed EnvironmentDevelopment of Air Quality Monitoring System in Closed Environment
Development of Air Quality Monitoring System in Closed Environment
 
Toxic Gas Detection-An Experiment with the Simulation Process
Toxic Gas Detection-An Experiment with the Simulation ProcessToxic Gas Detection-An Experiment with the Simulation Process
Toxic Gas Detection-An Experiment with the Simulation Process
 
A performance of radio frequency and signal strength of LoRa with BME280 sensor
A performance of radio frequency and signal strength of LoRa with BME280 sensorA performance of radio frequency and signal strength of LoRa with BME280 sensor
A performance of radio frequency and signal strength of LoRa with BME280 sensor
 
Prototype of multifunctional transmitter with Rejection of disturbances
Prototype of multifunctional transmitter with Rejection of disturbancesPrototype of multifunctional transmitter with Rejection of disturbances
Prototype of multifunctional transmitter with Rejection of disturbances
 
Smart Air Purifier with Air Quality Monitoring System
Smart Air Purifier with Air Quality Monitoring SystemSmart Air Purifier with Air Quality Monitoring System
Smart Air Purifier with Air Quality Monitoring System
 
New system of chaotic signal generation based on coupling coefficients applie...
New system of chaotic signal generation based on coupling coefficients applie...New system of chaotic signal generation based on coupling coefficients applie...
New system of chaotic signal generation based on coupling coefficients applie...
 
Differential equation fault location algorithm with harmonic effects in power...
Differential equation fault location algorithm with harmonic effects in power...Differential equation fault location algorithm with harmonic effects in power...
Differential equation fault location algorithm with harmonic effects in power...
 
Ultra-short Multi Soliton Generation for Application in Long Distance Commun...
Ultra-short Multi Soliton Generation for Application in Long Distance  Commun...Ultra-short Multi Soliton Generation for Application in Long Distance  Commun...
Ultra-short Multi Soliton Generation for Application in Long Distance Commun...
 
IRJET- Online Monitoring of Air Pollution using IoT
IRJET- Online Monitoring of Air Pollution using IoTIRJET- Online Monitoring of Air Pollution using IoT
IRJET- Online Monitoring of Air Pollution using IoT
 
Nonlinear chaotic signals generation and transmission within an optical fiber...
Nonlinear chaotic signals generation and transmission within an optical fiber...Nonlinear chaotic signals generation and transmission within an optical fiber...
Nonlinear chaotic signals generation and transmission within an optical fiber...
 
Secured Transportation of Quantum Codes Using Integrated PANDA-Add/drop and T...
Secured Transportation of Quantum Codes Using Integrated PANDA-Add/drop and T...Secured Transportation of Quantum Codes Using Integrated PANDA-Add/drop and T...
Secured Transportation of Quantum Codes Using Integrated PANDA-Add/drop and T...
 
Secured transportation of quantum codes using integrated panda adddrop and td...
Secured transportation of quantum codes using integrated panda adddrop and td...Secured transportation of quantum codes using integrated panda adddrop and td...
Secured transportation of quantum codes using integrated panda adddrop and td...
 
Nonlinear Chaotic Signals Generation and Transmission within an Optical Fiber...
Nonlinear Chaotic Signals Generation and Transmission within an Optical Fiber...Nonlinear Chaotic Signals Generation and Transmission within an Optical Fiber...
Nonlinear Chaotic Signals Generation and Transmission within an Optical Fiber...
 
I0315257
I0315257I0315257
I0315257
 

More from TELKOMNIKA JOURNAL

Amazon products reviews classification based on machine learning, deep learni...
Amazon products reviews classification based on machine learning, deep learni...Amazon products reviews classification based on machine learning, deep learni...
Amazon products reviews classification based on machine learning, deep learni...TELKOMNIKA JOURNAL
 
Design, simulation, and analysis of microstrip patch antenna for wireless app...
Design, simulation, and analysis of microstrip patch antenna for wireless app...Design, simulation, and analysis of microstrip patch antenna for wireless app...
Design, simulation, and analysis of microstrip patch antenna for wireless app...TELKOMNIKA JOURNAL
 
Design and simulation an optimal enhanced PI controller for congestion avoida...
Design and simulation an optimal enhanced PI controller for congestion avoida...Design and simulation an optimal enhanced PI controller for congestion avoida...
Design and simulation an optimal enhanced PI controller for congestion avoida...TELKOMNIKA JOURNAL
 
Improving the detection of intrusion in vehicular ad-hoc networks with modifi...
Improving the detection of intrusion in vehicular ad-hoc networks with modifi...Improving the detection of intrusion in vehicular ad-hoc networks with modifi...
Improving the detection of intrusion in vehicular ad-hoc networks with modifi...TELKOMNIKA JOURNAL
 
Conceptual model of internet banking adoption with perceived risk and trust f...
Conceptual model of internet banking adoption with perceived risk and trust f...Conceptual model of internet banking adoption with perceived risk and trust f...
Conceptual model of internet banking adoption with perceived risk and trust f...TELKOMNIKA JOURNAL
 
Efficient combined fuzzy logic and LMS algorithm for smart antenna
Efficient combined fuzzy logic and LMS algorithm for smart antennaEfficient combined fuzzy logic and LMS algorithm for smart antenna
Efficient combined fuzzy logic and LMS algorithm for smart antennaTELKOMNIKA JOURNAL
 
Wavelet-based sensing technique in cognitive radio network
Wavelet-based sensing technique in cognitive radio networkWavelet-based sensing technique in cognitive radio network
Wavelet-based sensing technique in cognitive radio networkTELKOMNIKA JOURNAL
 
A novel compact dual-band bandstop filter with enhanced rejection bands
A novel compact dual-band bandstop filter with enhanced rejection bandsA novel compact dual-band bandstop filter with enhanced rejection bands
A novel compact dual-band bandstop filter with enhanced rejection bandsTELKOMNIKA JOURNAL
 
Deep learning approach to DDoS attack with imbalanced data at the application...
Deep learning approach to DDoS attack with imbalanced data at the application...Deep learning approach to DDoS attack with imbalanced data at the application...
Deep learning approach to DDoS attack with imbalanced data at the application...TELKOMNIKA JOURNAL
 
Brief note on match and miss-match uncertainties
Brief note on match and miss-match uncertaintiesBrief note on match and miss-match uncertainties
Brief note on match and miss-match uncertaintiesTELKOMNIKA JOURNAL
 
Implementation of FinFET technology based low power 4×4 Wallace tree multipli...
Implementation of FinFET technology based low power 4×4 Wallace tree multipli...Implementation of FinFET technology based low power 4×4 Wallace tree multipli...
Implementation of FinFET technology based low power 4×4 Wallace tree multipli...TELKOMNIKA JOURNAL
 
Evaluation of the weighted-overlap add model with massive MIMO in a 5G system
Evaluation of the weighted-overlap add model with massive MIMO in a 5G systemEvaluation of the weighted-overlap add model with massive MIMO in a 5G system
Evaluation of the weighted-overlap add model with massive MIMO in a 5G systemTELKOMNIKA JOURNAL
 
Reflector antenna design in different frequencies using frequency selective s...
Reflector antenna design in different frequencies using frequency selective s...Reflector antenna design in different frequencies using frequency selective s...
Reflector antenna design in different frequencies using frequency selective s...TELKOMNIKA JOURNAL
 
Reagentless iron detection in water based on unclad fiber optical sensor
Reagentless iron detection in water based on unclad fiber optical sensorReagentless iron detection in water based on unclad fiber optical sensor
Reagentless iron detection in water based on unclad fiber optical sensorTELKOMNIKA JOURNAL
 
Impact of CuS counter electrode calcination temperature on quantum dot sensit...
Impact of CuS counter electrode calcination temperature on quantum dot sensit...Impact of CuS counter electrode calcination temperature on quantum dot sensit...
Impact of CuS counter electrode calcination temperature on quantum dot sensit...TELKOMNIKA JOURNAL
 
A progressive learning for structural tolerance online sequential extreme lea...
A progressive learning for structural tolerance online sequential extreme lea...A progressive learning for structural tolerance online sequential extreme lea...
A progressive learning for structural tolerance online sequential extreme lea...TELKOMNIKA JOURNAL
 
Electroencephalography-based brain-computer interface using neural networks
Electroencephalography-based brain-computer interface using neural networksElectroencephalography-based brain-computer interface using neural networks
Electroencephalography-based brain-computer interface using neural networksTELKOMNIKA JOURNAL
 
Adaptive segmentation algorithm based on level set model in medical imaging
Adaptive segmentation algorithm based on level set model in medical imagingAdaptive segmentation algorithm based on level set model in medical imaging
Adaptive segmentation algorithm based on level set model in medical imagingTELKOMNIKA JOURNAL
 
Automatic channel selection using shuffled frog leaping algorithm for EEG bas...
Automatic channel selection using shuffled frog leaping algorithm for EEG bas...Automatic channel selection using shuffled frog leaping algorithm for EEG bas...
Automatic channel selection using shuffled frog leaping algorithm for EEG bas...TELKOMNIKA JOURNAL
 
ResNet-n/DR: Automated diagnosis of diabetic retinopathy using a residual neu...
ResNet-n/DR: Automated diagnosis of diabetic retinopathy using a residual neu...ResNet-n/DR: Automated diagnosis of diabetic retinopathy using a residual neu...
ResNet-n/DR: Automated diagnosis of diabetic retinopathy using a residual neu...TELKOMNIKA JOURNAL
 

More from TELKOMNIKA JOURNAL (20)

Amazon products reviews classification based on machine learning, deep learni...
Amazon products reviews classification based on machine learning, deep learni...Amazon products reviews classification based on machine learning, deep learni...
Amazon products reviews classification based on machine learning, deep learni...
 
Design, simulation, and analysis of microstrip patch antenna for wireless app...
Design, simulation, and analysis of microstrip patch antenna for wireless app...Design, simulation, and analysis of microstrip patch antenna for wireless app...
Design, simulation, and analysis of microstrip patch antenna for wireless app...
 
Design and simulation an optimal enhanced PI controller for congestion avoida...
Design and simulation an optimal enhanced PI controller for congestion avoida...Design and simulation an optimal enhanced PI controller for congestion avoida...
Design and simulation an optimal enhanced PI controller for congestion avoida...
 
Improving the detection of intrusion in vehicular ad-hoc networks with modifi...
Improving the detection of intrusion in vehicular ad-hoc networks with modifi...Improving the detection of intrusion in vehicular ad-hoc networks with modifi...
Improving the detection of intrusion in vehicular ad-hoc networks with modifi...
 
Conceptual model of internet banking adoption with perceived risk and trust f...
Conceptual model of internet banking adoption with perceived risk and trust f...Conceptual model of internet banking adoption with perceived risk and trust f...
Conceptual model of internet banking adoption with perceived risk and trust f...
 
Efficient combined fuzzy logic and LMS algorithm for smart antenna
Efficient combined fuzzy logic and LMS algorithm for smart antennaEfficient combined fuzzy logic and LMS algorithm for smart antenna
Efficient combined fuzzy logic and LMS algorithm for smart antenna
 
Wavelet-based sensing technique in cognitive radio network
Wavelet-based sensing technique in cognitive radio networkWavelet-based sensing technique in cognitive radio network
Wavelet-based sensing technique in cognitive radio network
 
A novel compact dual-band bandstop filter with enhanced rejection bands
A novel compact dual-band bandstop filter with enhanced rejection bandsA novel compact dual-band bandstop filter with enhanced rejection bands
A novel compact dual-band bandstop filter with enhanced rejection bands
 
Deep learning approach to DDoS attack with imbalanced data at the application...
Deep learning approach to DDoS attack with imbalanced data at the application...Deep learning approach to DDoS attack with imbalanced data at the application...
Deep learning approach to DDoS attack with imbalanced data at the application...
 
Brief note on match and miss-match uncertainties
Brief note on match and miss-match uncertaintiesBrief note on match and miss-match uncertainties
Brief note on match and miss-match uncertainties
 
Implementation of FinFET technology based low power 4×4 Wallace tree multipli...
Implementation of FinFET technology based low power 4×4 Wallace tree multipli...Implementation of FinFET technology based low power 4×4 Wallace tree multipli...
Implementation of FinFET technology based low power 4×4 Wallace tree multipli...
 
Evaluation of the weighted-overlap add model with massive MIMO in a 5G system
Evaluation of the weighted-overlap add model with massive MIMO in a 5G systemEvaluation of the weighted-overlap add model with massive MIMO in a 5G system
Evaluation of the weighted-overlap add model with massive MIMO in a 5G system
 
Reflector antenna design in different frequencies using frequency selective s...
Reflector antenna design in different frequencies using frequency selective s...Reflector antenna design in different frequencies using frequency selective s...
Reflector antenna design in different frequencies using frequency selective s...
 
Reagentless iron detection in water based on unclad fiber optical sensor
Reagentless iron detection in water based on unclad fiber optical sensorReagentless iron detection in water based on unclad fiber optical sensor
Reagentless iron detection in water based on unclad fiber optical sensor
 
Impact of CuS counter electrode calcination temperature on quantum dot sensit...
Impact of CuS counter electrode calcination temperature on quantum dot sensit...Impact of CuS counter electrode calcination temperature on quantum dot sensit...
Impact of CuS counter electrode calcination temperature on quantum dot sensit...
 
A progressive learning for structural tolerance online sequential extreme lea...
A progressive learning for structural tolerance online sequential extreme lea...A progressive learning for structural tolerance online sequential extreme lea...
A progressive learning for structural tolerance online sequential extreme lea...
 
Electroencephalography-based brain-computer interface using neural networks
Electroencephalography-based brain-computer interface using neural networksElectroencephalography-based brain-computer interface using neural networks
Electroencephalography-based brain-computer interface using neural networks
 
Adaptive segmentation algorithm based on level set model in medical imaging
Adaptive segmentation algorithm based on level set model in medical imagingAdaptive segmentation algorithm based on level set model in medical imaging
Adaptive segmentation algorithm based on level set model in medical imaging
 
Automatic channel selection using shuffled frog leaping algorithm for EEG bas...
Automatic channel selection using shuffled frog leaping algorithm for EEG bas...Automatic channel selection using shuffled frog leaping algorithm for EEG bas...
Automatic channel selection using shuffled frog leaping algorithm for EEG bas...
 
ResNet-n/DR: Automated diagnosis of diabetic retinopathy using a residual neu...
ResNet-n/DR: Automated diagnosis of diabetic retinopathy using a residual neu...ResNet-n/DR: Automated diagnosis of diabetic retinopathy using a residual neu...
ResNet-n/DR: Automated diagnosis of diabetic retinopathy using a residual neu...
 

Recently uploaded

(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escortsranjana rawat
 
Introduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptxIntroduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptxupamatechverse
 
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
 
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130Suhani Kapoor
 
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLSMANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLSSIVASHANKAR N
 
UNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its PerformanceUNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its Performancesivaprakash250
 
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSAPPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSKurinjimalarL3
 
Introduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptxIntroduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptxupamatechverse
 
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...Christo Ananth
 
Porous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingPorous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingrakeshbaidya232001
 
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IVHARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IVRajaP95
 
Coefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxCoefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxAsutosh Ranjan
 
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130Suhani Kapoor
 
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...ranjana rawat
 
College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service NashikCollege Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service NashikCall Girls in Nagpur High Profile
 
UNIT-II FMM-Flow Through Circular Conduits
UNIT-II FMM-Flow Through Circular ConduitsUNIT-II FMM-Flow Through Circular Conduits
UNIT-II FMM-Flow Through Circular Conduitsrknatarajan
 
IMPLICATIONS OF THE ABOVE HOLISTIC UNDERSTANDING OF HARMONY ON PROFESSIONAL E...
IMPLICATIONS OF THE ABOVE HOLISTIC UNDERSTANDING OF HARMONY ON PROFESSIONAL E...IMPLICATIONS OF THE ABOVE HOLISTIC UNDERSTANDING OF HARMONY ON PROFESSIONAL E...
IMPLICATIONS OF THE ABOVE HOLISTIC UNDERSTANDING OF HARMONY ON PROFESSIONAL E...RajaP95
 
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...Soham Mondal
 
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...Call Girls in Nagpur High Profile
 

Recently uploaded (20)

(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
 
Introduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptxIntroduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptx
 
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
 
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
 
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLSMANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
 
UNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its PerformanceUNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its Performance
 
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSAPPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
 
Introduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptxIntroduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptx
 
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
 
Porous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingPorous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writing
 
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IVHARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
 
Coefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxCoefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptx
 
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
 
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
 
College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service NashikCollege Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
 
UNIT-II FMM-Flow Through Circular Conduits
UNIT-II FMM-Flow Through Circular ConduitsUNIT-II FMM-Flow Through Circular Conduits
UNIT-II FMM-Flow Through Circular Conduits
 
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINEDJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
 
IMPLICATIONS OF THE ABOVE HOLISTIC UNDERSTANDING OF HARMONY ON PROFESSIONAL E...
IMPLICATIONS OF THE ABOVE HOLISTIC UNDERSTANDING OF HARMONY ON PROFESSIONAL E...IMPLICATIONS OF THE ABOVE HOLISTIC UNDERSTANDING OF HARMONY ON PROFESSIONAL E...
IMPLICATIONS OF THE ABOVE HOLISTIC UNDERSTANDING OF HARMONY ON PROFESSIONAL E...
 
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
 
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...
 

Harmful Gases Profiling in Meru Menora Tunnel using SICK Sensor

  • 1. TELKOMNIKA, Vol.15, No.2, June 2017, pp. 888~894 ISSN: 1693-6930, accredited A by DIKTI, Decree No: 58/DIKTI/Kep/2013 DOI: 10.12928/TELKOMNIKA.v15i2.6141  888 Received February 7, 2017; Revised April 28, 2017; Accepted May 10, 2017 Harmful Gases Profiling in Meru Menora Tunnel using SICK Sensor A. N. Baharun 1 , N. A. Murad 2 , N. N. N. A. Malik 3 1 Persada PLUS, Persimpangan Bertingkat Subang, KM15, Lebuhraya Baru Lembah Klang, 47301 Petaling Jaya Selangor 2,3 Advanced RF and Microwave Research Group (ARFMRG), Communication Engineering Department, Faculty of Electrical Engineering, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor Abstract This paper discusses the study on the measured harmful gases due to traffic emission in the Meru Menora Tunnel, a Malaysia highway tunnel. The hazardous gasses data would help in promoting essential ventilation system inside the tunnel for the health and safety of the users. The emission gasses concentration reading is divided into two main components comprise of Nitrogen Dioxide (NO2), and Carbon Monoxide (CO). Other than that, the visibility also been measured by using SICK sensor. The measurement has been done during normal, festive and school holiday seasons. Festive season shows the highest number of traffic and thus giving the worst air quality. Ventilation fan system can be activated based on the concentration level of gases and visibility in the tunnel. Keywords: Harmful gas, SCADA, Tunnel, SICK sensor, in tunnel ventilation Copyright © 2017 Universitas Ahmad Dahlan. All rights reserved. 1. Introduction The increasing number of vehicles on the road urged the enhancement of traffic flow and safety especially in heavy traffic highway line. The monitoring system on Meru Menora Tunnel infrastructure due to mountainous landscape on the Malaysia highway line is vital. Diesel emissions spread hazardous gasses that could be harmful to the users. Thus efficient ventilation system is crucial at peak traffic fleet inside the tunnel. In a tunnel, harmful gases can accumulate and became hazardous to the tunnel user and maintenance working staff. Gasses in diesel smoke comprises of Nitrogen Oxides (NOx), Carbon Monoxide (CO), Carbon Dioxide (CO2), Sulfur Dioxide (SO2) and other oxygenated hydrocarbons such as acetaldehyde and formaldehyde [1]. A high concentration can be hazardous particularly in certain circumstances involving traffic collisions where smoke from a small fire can reduce the visibility with possibility of explosion due to the accumulate gasses [2].Therefore, an air ventilation system is needed to reduce the gases concentration in the tunnel to ensure the health and safety of the user. A monitoring system is essential to monitor and determine the gas concentration and visibility in the tunnel. This paper focuses on the harmful gases monitoring inside the Meru Menora Tunnel. The tunnel is located in Northern Malaysia with 861 meter long. It is run in 2 separated tubes; one for north-going traffic and one for south-going traffic, each with two lanes. Figure 1 shows the layout of the Meru Menora Tunnel. Figure 1. Meru Menora Tunnel layout studied section.
  • 2. TELKOMNIKA ISSN: 1693-6930  Harmful Gases Profiling in Meru Menora Tunnel using SICK Sensor (A. N. Baharun) 889 More than ten momentum ventilation fans are operated at 11kW in each tube to assist the slow traffic or in case of fire. In the tunnel, 15 fire hydrants is provided and equied with 14 ventilation shafts for exhausting polluted air through ventilation fan that is located along north- going tunnel. 2. Data Collection Monitoring the condition inside the tunnel is vital to ensure the smooth traffic as well as maintaining the safety of the users. For time being the monitoring system is not fully automated. The enhancement of the system can facilitate real time control by the authorities remotely as well as on site. Automated monitoring system can be realized using Supervisory Control and Data Acquisition (SCADA) system. It is defined as a system that operates to monitor, control and analysis the process that generate from various remote devices [3-8]. Programmable Logic Controller (PLC) or Remote Terminal Unit (RTU) acts as data collector and relay the information to the master station for the operator to perform remote control tasks [9-11]. The system required monitoring data and process for further action. In particular, the harmful gases concentration is the data monitored through the Human Machine Interface (HMI). The data is collected by using SICK sensor that measure the concentration of Nitrogen Dioxide (NO2), Carbon Monoxide (CO) and air visibility. The collected data is used to trigger the ventilation fan to operate and reduce the gasses concentration. An automated ventilation system can minimize the energy consumption with selected fan for ventilations. The gases concentration is determined by using Differential Optical Absorption Spectroscopy (DOAS) where the technique used Ultra Violet (UV) and visible region to analyze broadband spectra transmitted through a long open path [12]. In [12], Beer-Lamberts Law proposed that: ( , , )= 0( ) − ( , , ) (1) where I( ) = intensities I0( ) = unattended reference intensities L = path length in cm, ( ) = the wavelength, pressure, temperature dependent absorption cross sections [cm2.molecule-1] n = denoted as the number density of the species [molecules/cm3]. Equation (2) is proposed by adding Rayleigh and Mie scattering to (1) as both scattering contribute to the radiation extinction, where Equation (2) is as follows: ( , , )= 0( ). {Σ[− ( , , )× − ( )− ( )]× }. ( ) (2) where ( ) is the Rayleigh extinction coefficient product of Rayleigh cross section, R( ) and the number density of air, nair. Meanwhile, ( ) is Mie extinction coefficient that correspond to M( )nair. ( ) is attenuation of the instrument optics while denote as atmospheric or gas species. 0( )is determined in open atmosphere and the total cross section ( ) as follow: = + ′ (3) where is the one slowly varying with wavelength and ′ is the one rapidly varying. After substitute Equation (3) into Equation (2), Equation (4) is produced as: ( , , )= 0( ). [−Σ ′( , , )× × ] {Σ−[ ( , , )× + ( )+ ( )]× }. ( ) (4) Intensity in the absence of differential absorption 0′can be estimated using Polynomial fit, Digital smoothing or Fourier transform. Therefore, Equation (4) will turn toEquation (5): ( , , )= 0′( ) [−Σ ′( , , )× × ] (5)
  • 3.  ISSN: 1693-6930 TELKOMNIKA Vol. 15, No. 2, June 2017 : 888 – 894 890 The process of SICK sensor data capturing begin with the laser to shot from sender and receiver. Then the sensor at receiver analyzes the reading and sent the data to converter. Fiber converter at substation panel converts the data and sent it through fiber network straight to Ethernet converter in server room. Next, data is sent through the Ethernet to the SCADA system. From SCADA, fan speed is determined based on the pre-set and the signal is sent to panel in server room. The signal is converted to fiber signal and is sent by using the fiber network to the VSD. After receive the signal, VSD runs the fan at its desired speed and response signal back to SCADA system. Response from VSD is read by SCADA and view new speed of the fan. Figure 2 presents the configuration of SCADA system test for the sensor. Firstly, VICOTEX sensor sender emit infrared signal to receiver with the right alignment aim to achieve maximum signal strengths with the minimum possible gain setting Then, receiver sensor analyzes the reading and sent it to PLC in current 4-20mA format. After signal is received, the PLC processes the data and sent TCP/IP signal to SCADA system through Local Area Network (LAN). SCADA software will recognize the signal and display on the HMI. Figure 3 shows the graph conversion from current signal to gas concentration. The graph is constructed by measuring the current signal sent by the sensor and the concentration display on the HMI. As example, when the signal input is 20 mA, the concentration of the gas will be 27648 m. Meanwhile, the minimum current of 4 mA will produce 0 m gas. The current value is analog value from sensor to the PLC. Figure 2. SCADA system test setup Figure 3. Current signal to gas concentration graph conversion Table 1 show the value of m produces when we aly the graph on Fig. 4 which is as a reference of connection between Analogue signal (mA) and Output Software. The test kit value shall verify the system functionality by using Tunnel Sensor Control Unit (VICOTEX/TSCU) Utility Software to ensure correct issue and receipt of commands as well as response of the command through status monitoring using SCADA HMI. The value of gases in the Meru Menora Tunnel will simulate analog output using VICONOX/TSCU Utility software to sensor and compare to the reading show in SCADA HMI. Table 1. Value from test kit Simulation (mA) 4 % 12 % 20 % Visibility (m) 1.1 1.1% 55.3 55.3% 100 100% NO2 (m) 0.2 0.05% 198.6 49% 399.8 100% Analogue (4-20mA) SCADA Simulator (Installed on laptop)
  • 4. TELKOMNIKA ISSN: 1693-6930  Harmful Gases Profiling in Meru Menora Tunnel using SICK Sensor (A. N. Baharun) 891 CO (m) 43 1.73% 1296.5 52.25% 2481.2 100% The arrangement of the ventilation fan is shown in Figure 4. Table 2 shows the level set of ventilation fan according to several set points according to the minimum standard value. The levels are divided into 5. Level 0 is the minimum level which operates with 4 fans at 30 Hz frequency speed. Meanwhile, Level 4 mode operates as maximum mode with 12 fans switch on at 45 frequency speed. Figure 4. Ventilation fan location in the Meru Menora Tunnel Table 2. Operation level of ventilation fan Level Set Points Visibility (m) CO (m) NO2 (m) Fan Frequency (Hz) No. of Fans Active 0 < 2.0 < 20 < 0.5 30 4 1 2.5 20 0.5 35 4 2 5.0 40 1.0 35 7 3 7.5 60 1.5 40 7 4 10.0 80 2.5 45 12 3. Results and Analysis Table 3 shows the calculated number of vehicles in a week for Normal, Festive and School Holiday season respectively. The Festive season recorded the highest total vehicles followed by School Holiday, while Normal shows the lowest number. At peak Festive season, the air quality is expected to be the worst as the number of vehicles is more than usual. The air quality in term of visibility and gasses concentration is shown in Figure 5. The most harmful NO2 gas shows an extremely low reading while visibility reading is at 3 ± 1 m. The CO gas is average at 5 m, however increased by 10 m in the afternoon. Thus, 4 fans at the speed of 35 Hz is activated for ventilation purposes. The ventilation is hoped to reduce the gasses concentration, thus reducing the risk of fire, explosion, and gas poisoning as well as increasing the visibility. Figure 6 shows the comparison of visibility during Normal, Festive and School Holiday season. The visibility in Normal condition is less than 0.5 m since the vehicles flow through the Meru Menora Tunnel is less compared to School Holiday season. The traffic is increased during School holiday in both direction, North and South-going. Thus, the visibility reading increased around 1.5 m. Meanwhile, in Festive season, the heavy traffic increased the reading up to 2 m.
  • 5.  ISSN: 1693-6930 TELKOMNIKA Vol. 15, No. 2, June 2017 : 888 – 894 892 Table 3. Total vehicles for Normal, Festive and School Holiday Season respectively Day SEASON Normal Festive School Holiday 1 20057 22293 21601 2 22041 27022 25418 3 21685 29516 24490 4 19179 28661 20416 5 19076 34758 21685 6 20494 36306 21506 7 19214 25863 22315 TOTAL 141746 204419 157431 Figure 5. Air Qualities for Festive Season Figure 6. Visibility comparison during Festive, Holiday and Normal season Nitrogen Dioxide (NO2) gas reading is shown in Figure 7. The reading is less than 0.002 m for both Normal and School Holiday season. For Festive season, it can be observed that the NO2 gas reading is increased up to 0.016 m due to the heavy traffic. As the time flow, the vehicle flow also increase, thus, the harmful gas also increase and reduce the gas concentration helps the tunnel user drive safely. Comparison of Carbon Monoxide (CO) gas concentration is illustrated in Figure 8. In Normal season, the reading is less than 4 m meanwhile in School Holiday; the reading shows that the CO gas concentration is less than 6 m. However, there is slightly increment between 5-7 am which recorded 11 m reading. In Festive season, the gas concentration is highest at 16 m measured at 4 pm and recorded 15 m at 5 pm. The reading shows that the ventilation fan helps to reduce the gas concentration.
  • 6. TELKOMNIKA ISSN: 1693-6930  Harmful Gases Profiling in Meru Menora Tunnel using SICK Sensor (A. N. Baharun) 893 Figure 7. Nitrogen Dioxide (NO2) gas concentration reading comparison Figure 8. Comparison of Carbon Monoxide (CO) gas concentration reading. Figure 9 presents the fan speed for Festive, Holiday and Normal season. The fan speed is simulated based on Table 2 and input from measured visibility, NO2 and CO gas shows in Figure 6, 7 and 8, respectively. In Figure 9, measured gas during festive season simulate varies fan speed from 12 am to 9 am. As example, at 12 am, the fan speed is at 30 Hz and increase to 35 Hz when time increase to 1 am. Meanwhile, the fan speed from 3 to 6 am is nearly constant about 35 Hz. Besides, from 9 am to 11 pm, the fan speed is constant a minimum 30 Hz. Holiday and Normal season shows constant fan speed at 30 Hz. Based on the fan speed simulation, the increase number of vehicles during Festive season increase the gas concentration. Thus, increase the fan speed.
  • 7.  ISSN: 1693-6930 TELKOMNIKA Vol. 15, No. 2, June 2017 : 888 – 894 894 Figure 9. Simulated fan speed of festive, holiday and normal season 4. Conclusion The air quality inside the Meru Menora Tunnel in term of visibility, CO gas and NO2 gas are measured and analysed to promote essential ventilation for health and safety purposes. The ventilation fan system in Meru Menora Tunnel also discussed. The fan system will operate depending on the gasses concentration level, thus not all fan are operated at one time. This will encourage an efficient power consuming by selecting certain fan configuration at certain frequency. Data on total vehicles shows that Festive season is highest compared to Normal and School Holiday season. Besides, the fan speed also increases due to the increase of vehicle during Festive season. Therefore, the gasses concentration is the highest during Festive season compared to other season. It is expected to have a better ventilation system during Festive season when the traffic is high. Acknowledgements The authors would like to thank the Research Management Centre (RMC), School of Postgraduate (SPS), Communication Engineering Department (COMM) Universiti Teknologi Malaysia (UTM) and all members of Advanced Microwave Lab P18 FKE-UTM for giving motivation, knowledge sharing and suort of the research under grant no 10H04. References [1] S Sanxiang, Z Yunxia. Monitoring of Harmful Gas for Yangbajing 1# Tunnel in High Altitude Plateau. Measuring Technology and Mechatronics Automation (ICMTMA). 2014 Sixth International Conference on. 2014: 410-412. [2] XC Jiao. The road tunnel fire detection of multi-parameters based on BP neural network. Informatics in Control, Automation and Robotics (CAR), 2nd International Asia Conference on. 2010; 246-249. [3] A Daneels, W Salter. What is SCADA?. International Conference on Accelerator and Large Experimental Physics Control Systems. 1999. [4] Boyer, Stuart A. SCADA Supervisory Control and Data Acquisition. USA: ISA -International Society of Automation. 2010; 179. ISBN 978-1-936007-09-7. [5] Xie Lu. Supervisory Control and Data Acquisition System Design for CO2 Enhanced Oil Recovery. Electrical and Computer Sciences. University of California. 2014. [6] Boys, Walt. Back to Basics: SCADA. Automation TV: Control Global-Control Design. 2009. [7] M Kover-Dorco. SCADA system creation by using java alications and PLC. Control Conference (ICCC). 2014 15th International Carpathian. 2014: 264-267. [8] M Avhad, V Divekar, H Golatkar, S Joshi. Microcontroller based automation system using industry standard SCADA. India Conference (INDICON), 2013 Annual IEEE. 2013: 1-6. [9] M Ahmed, W Soo. Customized SCADA system for low voltage distribution automation system. in Transmission & Distribution Conference & Exposition: Asia and Pacific. 2009: 1-4. [10] M Sreejeth, M Singh, P Kumar, P Varshney, P Sachdeva. Implementation of supervisory control system for PMSM drive. Power Electronics (IICPE), IEEE 5th India International Conference on, 2012: 1-6. [11] MM Ahmed, W Soo. Supervisory control and data acquisition system (SCADA) based customized remote terminal unit (RTU) for distribution automation system. Power and Energy Conference. PECon 2008. IEEE 2nd International. 2008: 1655-1660.