Abstract—Concrete is found to undergo degradation when
subjected to elevated temperatures and loose substantial amount of its
strength. The loss of strength in concrete is mainly attributed to
decomposition of C-S-H and release of physically and chemically
bound water, which begins when the exposure temperature exceeds
100°C. When such a concrete comes in contact with moisture, the
cement paste is found rehydrate and considerable amount of strength
lost is found to recover. This paper presents results of an
experimental program carried out to investigate the effect of recuring
on strength gain of OPC concrete specimens subjected to elevated
temperatures from 200°C to 800°C, which were subjected to
retention time of two hours and four hours at the designated
temperature. Strength recoveries for concrete subjected to 7
designated elevated temperatures are compared. It is found that the
efficacy of recuring as a measure of strength recovery reduces with
increase in exposure temperature.
Keywords—Elevated Temperature, Recuring, Strength Recovery,
Compressive strength.
I. INTRODUCTION
ONCRETE is a very popular construction material and it
finds its application in almost all the civil engineering
disciplines. It’s characteristics such as mouldability and high
compressive strength has made it a versatile building material.
Concrete offers good resistance to heat because of its low
conductivity and incombustible nature and further, no toxic
fumes are emitted from concrete surface when it is heated.
Because of all these characteristics concrete can be rated as
the best building material as far as resistance to elevated
temperature is concerned
The concrete basically consists of two phases, the aggregate
phase and the hardened cement paste phase. There is a thermal
incompatibility between the aggregate phase and hardened
paste phase which initializes the cracking process when the
concrete is heated [1]. The cement paste begins to the
dehydrate at about 110°C [2] and as the temperature rises
above 300°C there will be subsequent decomposition of
Ca(OH)2 and the calcium silicate hydrates as the temperature
progresses above 600°C [3].
The tendency of aggregates is to expand due to high
temperature before disintegration. This differential thermal
expansion between aggregates and cement paste leads to
Shree Laxmi Prashant, Asst Prof., is with the Department of Civil
Engineering, MIT Manipal, Udupi 576104 (e-mail:
shrilaxmi.civil@gmail.com).
Subhash C. Yaragal and K. S. Babu Narayan are Professors with the
Department of Civil Engineering, National Institute of Technology Karnataka,
Surathkal, Srinivasnagar-575025, Mangalore, India (e-mail:
subhashyaragal@yahoo.com, shrilalisuta@gmail.com).
surface crazing which further leads to deeper cracking [4].
Aggregate stability has a major influence on performance of
concrete at elevated temperature and the deterioration [5], [6].
The differential thermal expansion combined with
decomposition of CSH gel leads to deterioration of ITZ, which
is one of the major causes of deterioration of concrete strength
[7], [8].
Whenever structural concrete is subjected to elevated
temperatures its effects can be visualized in the form of
surface cracking, spalling, and disintegration that render the
concrete structure unserviceable. The damaged concrete
surface is usually repaired by removing the weak layers of
concrete (or where the cement paste has lost significant
amount of binding property) and their replacement with fresh
concrete. But studies conducted by [8], indicate any thermally
damaged concrete has the tendency to recover the lost strength
by rehydration whenever the concrete is exposed to moist
environment. In their studies they found the concrete to
recover almost 80% of its original strength in the span of
about 12 months. Studies on similar lines were carried out by
[9], wherein the thermally deteriorated concrete were
subjected to air and water curing. It was found that if the
thermally exposed concrete is given constant moisture supply
the concrete rehydrates itself to recover the strength and
durability.
The strength deterioration of concrete is attributed to the
coarsening of pore structure and opening of the capillaries,
due to dehydration of the gel, that were initially filled by the
hydration products. When moisture is supplied to such
concrete partial rehydration of cement paste will take place
and the capillaries created due the elevated temperature
exposure will be refilled by rehydration process [10]. This
rehydration is expected to result in regain of certain amount of
its lost original strength. The compressive strength of certain
cement pastes does not reduce much even up to 500°C or
higher [11]. This paper presents the results of the effect of 7,
14, 28 and 56 days of water recuring of thermally deteriorated
OPC concrete cubes (100 mm) on their compressive strength.
II.EXPERIMENTAL METHODOLOGY
Ordinary Portland Cement 43 grade with brand name ACC
was used for preparing the concrete specimens. The chemical
composition of the cement is given in Table I. River sand
conforming to zone 3 (I.S 383-1970 grading requirements)
with specific gravity 2.65 was used. Coarse aggregates with
specific gravity 2.77 satisfying I.S 383-1970 [12] grading
requirements for graded aggregates were used. The mix
proportion is given in Table II.
Shree Laxmi Prashant, Subhash C. Yaragal, K. S. Babu Narayan
Recurring as a Means of Partial Strength Recovery
of Concrete Subjected to Elevated Temperatures
C
World Academy of Science, Engineering and Technology
International Journal of Civil, Environmental, Structural, Construction and Architectural Engineering Vol:9, No:3, 2015
270International Scholarly and Scientific Research & Innovation 9(3) 2015
InternationalScienceIndexVol:9,No:3,2015waset.org/Publication/10000795
in
ho
da
el
ra
te
te
20
7°
w
or
sw
th
(3
re
co
fo
se
re
ag
I
Sulph
L
C
Water Ce
0.45
The concrete
nto moulds of
ours the conc
ays under w
levated tempe
ange was 200
mperature bu
mperature tim
0°C/min and
°C/min.
After the ta
were maintaine
rder to achie
witched off an
he interior of t
3 nos.) of sp
etained after ex
ooled specime
or 7, 14, 28 an
et on 7th, 14th
ecuring. The r
gainst the stren
T
CHEMICAL COM
Soluble Silica (%
Alumina (%)
Iron Oxide (%
Lime (%)
Magnesium (%
Insoluble Residue
hur (Sulphur Triox
Loss On Ignition
Chloride Content
TA
MIX P
ment Fine A
1 1
e was mixed
f size 100mm
crete cubes w
ater. The co
erature in an
0°C to 800°C
uild up during
me gradient
flattens grad
arget tempera
ed at that tem
eve thermal
nd the specim
the furnace re
pecimen was
xposure to ele
ens were then
nd 56 days. De
h and 28th day
residual stren
ngth of concre
Fig. 1 Time
TABLE I
MPOSITION OF CEM
%)
)
%)
%)
e (%)
xide) (%)
(%)
t (%)
ABLE II
PROPORTION
Aggregate
1.198
in a concret
m x 100mm
were demoulde
oncrete cubes
electric oven
C at an inter
test was as s
steepens up
dually above
ature was rea
mperature for
steady state
mens were left
eached room t
tested to ev
evated temper
n immersed in
estructive testi
y to evaluate th
ngth after recu
ete at ambient
temperature cu
MENT
21.6
5
3.7
63.1
0.8
1.8
2.1
2
0.01
Coarse Aggreg
2.23
10mm
0.877
20
2
te mixer and
x 100mm. A
ed and cured
s were subjec
n target temp
rval of 100°C
shown in Fig.
p to 400°C
400°C is at
ached the spe
duration of 2
. The furnac
t in the furnac
temperature. O
valuate the s
ratures. The na
n water for r
ing was done
he strength ga
uring was co
t temperature.
urve
gate
0mm
.046
poured
After 24
for 28
cted to
perature
C. The
1. The
around
rate of
ecimens
2 hrs in
ce was
ce until
One set
strength
aturally
recuring
for one
ain after
mpared
alo
sub
sur
rep
ch
to
tar
co
the
ed
cra
de
res
str
exp
co
sub
co
30
res
an
Af
co
str
de
7 a
am
reg
50
cal
tem
its
the
the
fill
I
A.Visual Obs
Fig. 2 shows
ong with the
bjected to ele
rface cracking
ported by prev
hanged from n
grey (700°C-
rget temperat
ncrete subjec
e surface of
dges. However
acking after
terioration on
sulting into su
B.Strength D
Fig. 3 shows
rength ratio,
posure to ele
nditions) due
bsequent reco
ncrete subjec
00°C retained
spectively. Af
nd 300°C expo
fter 56 days
ncrete recove
rength respect
The concret
terioration of
and 14 days,
mbient strengt
gained 83%
00°C and abov
lcium hydroxi
mperature of 5
ambient stren
e cement pas
ereby creating
led by new hy
III. RESULTS
servations
s the surface
e concrete a
evated temper
g. Changes re
vious research
normal (at amb
800°C). Colo
ture. Fig. 2
cted to 800°C
the cubes, bu
r no spalling
700°C and
n bond betwe
ubstantial loss
Fig. 2 Concret
Deterioration a
s the deterior
which is the
evated temper
e to elevated
overy with con
cted to an ele
about 92 and
fter recuring f
osed concrete
of recuring,
ered almost
ively.
te exposed
25% of its am
concrete rega
th. After 56
of its ambien
ve the cement
ide and the C
500°C and abo
ngth since aft
ste loses its i
g large voids
ydration produ
S AND DISCUSS
e of concrete
at room tem
rature showed
eported here
hers [3], [11].
bient conditio
or changes are
also shows
C. Cracks are
ut were more
of edges has
800°C expo
een cement p
of strength.
e exposed to 80
and Recovery
ration of stre
ratio of reta
atures to the
d temperature
ntinuing recur
evated temper
d 81 % of the
for 7 days th
is about 94 an
the 200°C a
95% and 85
to 400°C
mbient strengt
ained about 7
days of recu
nt strength. T
t paste hydrati
SH deteriorat
ove the recov
fter exposure t
interlayer wat
s which are v
ucts. Partial f
SIONS
exposed to
mperature. Co
d colour chan
are similar to
. The concrete
ons) to pink (4
found to dep
severe crack
distributed a
e pronounced
taken place.
osure signifi
aste and aggr
00°C
ength (Expres
ained strength
strength at am
e exposure a
ring till 56 day
rature of 200°
eir ambient st
e strength of
nd 83% respec
and 300°C ex
5% of its am
suffered st
h. After recur
77% and 79%
urring, concre
The temperat
ion products s
es. For the ex
ery is below 7
to 500°C and
ter and bond
very difficult
filling ability o
800°C
oncrete
ge and
o those
e color
400°C)
end on
king of
ll over
at the
Severe
es the
regates
ssed as
h after
mbient
and its
ys. The
°C and
trength
200°C
ctively.
xposed
mbient
trength
ring for
% of its
ete had
ture of
such as
xposure
75% of
d above
d water
t to be
of new
World Academy of Science, Engineering and Technology
International Journal of Civil, Environmental, Structural, Construction and Architectural Engineering Vol:9, No:3, 2015
271International Scholarly and Scientific Research & Innovation 9(3) 2015
InternationalScienceIndexVol:9,No:3,2015waset.org/Publication/10000795
hydration products will help in partial recovery of lost
strength.
Fig. 3 Strength improvement through recuring for concrete subjected
to heating for 2 hrs
Fig. 4 Strength improvement through recuring for concrete subjected
to heating for 4 hrs
Concrete exposed to 600°C experienced large deterioration
of strength and the residual strength is only about 50%. After
recuring the concrete regained 18% of its ambient strength in
just 7 days. At the end of 56 days of recuring the residual
strength recovered is 66% of its ambient strength. Similarly
for 700°C and 800°C the concrete had suffered severe strength
loss, on recuring recovered 61% and 52% of its ambient
strength.
Fig. 4 shows the effect of recuring for the thermally
deteriorated concrete exposed to heating for 4 hrs. For the
concrete exposed to 400°C the gain in strength was observed
but comparatively slower as compared to the concrete exposed
to 2 hr heating. For the exposure temperatures of 500°C and
600°C the strength recovery was not very appreciable, while
the concrete specimen exposed to 700°C and 800°C were
damaged to an extent that they lost their integrity and hence
could not be recured.
The concrete with exposure duration of 3hr and 4hr
recovered about 21 and 34% of the lost strength respectively
after recuring for 56 days.
IV. CONCLUSIONS
1. Recuring is the most economical and easiest technique to
recover the strength lost as a result of elevated
temperature exposure. Concrete regains its lost strength
because if constant supply of moisture to the dehydrated
cement paste.
2. For lower temperature substantial amount of strength is
recovered after recuring, for higher temperatures (above
400°C) all the lost strength cannot be recovered because
the new hydration products formed as a result of recuring,
fill the voids and cracks formed as a result of elevated
temperature exposure partially.
3. The rate of strength gain is faster during the initial 7 days
of recuirng and later slows down.
4. Recuring capacity of the dehydrated cement paste
decreases with the increase in exposure duration.
5. The technique of recuring is significant as it could reduce
the expenses required for repair and rehabilation of
thermally deteriorated concrete and conserve resources.
REFERENCES
[1] J P olliver, J C Maso, B Bourdette. “Interfacial Transition Zone in
Concrete”. Advanced cement based materials vol.2, pp.30-38, 1995.
[2] Y. Xu, Y.L. Wong, C.S. Poon, M. Anson. “Influence of PFA on
cracking of concrete and cement paste after exposure to high
temperatures”, Cement and Concrete Research vol 33, pp. 2009–2016,
2003.
[3] Khoury G A, Majrona C E, Pasavento F Shrefler B A. “Modeling of
heated concrete”. Magazine of Concrete Research, 54 vol 77 pp.101,
2002.
[4] Arioz O. “Effects of elevated temperatures on properties of concrete”
Fire Safety Journal vol 42, pp. 516-522, 2007.
[5] B. Georgali, P. E. Tsakiridis. Microstructure of fire-damaged concrete.
A case study Cement & Concrete Composites 27, 2005 255–259.
[6] D Campbell Allen,P M Desai. Influence of aggregate on behavior of
concrete at elevated temperatures, Nuclear Engineering and Design, 6,
August 1967, Pages 65-77.
[7] S C Chakrabarti, K N Sharma and Abha Mittal, ‘Residual strength in
concrete after exposure to elevated temperature, The Indian Concrete
Journal, Dec 1994 713-717.
[8] Chi-Sun Poon, Salman Azhar, Mike Anson, Yuk-Lung Wong, “Strength
and durability recovery of fire-damaged concrete after post-fire-
curing”,Cement and Concrete Research, Volume 31, Issue 9, September
2001, Pages 1307-1318.
[9] C. Alonso, L. Fernandez. “Dehydration and rehydration processes of
cement paste exposed to high temperature environments”, Journal of
Materials Science vol 39 pp.3015 – 3024, 2004.
[10] Gabriel A. Khoury and Patrick J. E. Sullivan, ‘Research at Imperial
College on the Effect of Elevated Temperatures on Concrete’, Fire
Safety Journal, vol-13, pp.69 – 72, 1988.
[11] Yuzer, Nabi , Fevziye Akoz, Leyla Dokuzer O zturk, “Compressive
strength–color change relation in mortars at high temperature”, Cement
and Concrete Research vol- 34 pp.1803–1807, 2004.
[12] IS: 383-1970 "Specifications for coarse and fine aggregates from natural
sources for concrete", Bureau of Indian Standards, New Delhi.  
0.00
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
1.00
0 20 40 60
Strength Ratio
Recuring days
200
300
400
500
600
700
800
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
0 7 14 21 28 35 42 49 56
StrengthRatio
Recuring (days)
200
300
400
500
600
World Academy of Science, Engineering and Technology
International Journal of Civil, Environmental, Structural, Construction and Architectural Engineering Vol:9, No:3, 2015
272International Scholarly and Scientific Research & Innovation 9(3) 2015
InternationalScienceIndexVol:9,No:3,2015waset.org/Publication/10000795

More Related Content

What's hot

Resistance of Fly Ash and Silica Fume Based Glass Fiber Reinforced High-Perfo...
Resistance of Fly Ash and Silica Fume Based Glass Fiber Reinforced High-Perfo...Resistance of Fly Ash and Silica Fume Based Glass Fiber Reinforced High-Perfo...
Resistance of Fly Ash and Silica Fume Based Glass Fiber Reinforced High-Perfo...RSIS International
 
Cracking tendency of alkali-activated slag concrete
Cracking tendency of alkali-activated slag concreteCracking tendency of alkali-activated slag concrete
Cracking tendency of alkali-activated slag concretefrank collins
 
The environmental impacts of calcium chloride addition to cement on reinforci...
The environmental impacts of calcium chloride addition to cement on reinforci...The environmental impacts of calcium chloride addition to cement on reinforci...
The environmental impacts of calcium chloride addition to cement on reinforci...Alexander Decker
 
Paper publication in international journal
Paper publication in international journalPaper publication in international journal
Paper publication in international journalAravinda Bommareddy
 
Study on the fire resistant design of reinforced concrete flexural members
Study on the fire resistant design of reinforced concrete flexural membersStudy on the fire resistant design of reinforced concrete flexural members
Study on the fire resistant design of reinforced concrete flexural memberseSAT Journals
 
Strength and durability studies on silica fume modified high volume fly ash c...
Strength and durability studies on silica fume modified high volume fly ash c...Strength and durability studies on silica fume modified high volume fly ash c...
Strength and durability studies on silica fume modified high volume fly ash c...IAEME Publication
 
Effect of sulfate on the properties of self compacting concrete 2
Effect of sulfate on the properties of self compacting concrete 2Effect of sulfate on the properties of self compacting concrete 2
Effect of sulfate on the properties of self compacting concrete 2IAEME Publication
 
Corrosion resistance performance of fly ash blended cement concretes
Corrosion resistance performance of fly ash blended cement concretesCorrosion resistance performance of fly ash blended cement concretes
Corrosion resistance performance of fly ash blended cement concreteseSAT Publishing House
 
ACIMaterialsJournalV97(5)
ACIMaterialsJournalV97(5)ACIMaterialsJournalV97(5)
ACIMaterialsJournalV97(5)frank collins
 
COMPRESSIVE STRENGTH AND CARBONATION OF SEA WATER CURED BLENDED CONCRETE
COMPRESSIVE STRENGTH AND CARBONATION OF SEA WATER CURED BLENDED CONCRETE COMPRESSIVE STRENGTH AND CARBONATION OF SEA WATER CURED BLENDED CONCRETE
COMPRESSIVE STRENGTH AND CARBONATION OF SEA WATER CURED BLENDED CONCRETE IAEME Publication
 
Microstructure and Abrasive Wear Properties of Chrome Alloy Steel
Microstructure and Abrasive Wear Properties of Chrome Alloy Steel Microstructure and Abrasive Wear Properties of Chrome Alloy Steel
Microstructure and Abrasive Wear Properties of Chrome Alloy Steel IDES Editor
 
Lec02 Material Properties of Concrete and Steel (Reinforced Concrete Design I...
Lec02 Material Properties of Concrete and Steel (Reinforced Concrete Design I...Lec02 Material Properties of Concrete and Steel (Reinforced Concrete Design I...
Lec02 Material Properties of Concrete and Steel (Reinforced Concrete Design I...Hossam Shafiq II
 
Study Of Mechanical Properties Of High Strength Concrete By Partial Replaceme...
Study Of Mechanical Properties Of High Strength Concrete By Partial Replaceme...Study Of Mechanical Properties Of High Strength Concrete By Partial Replaceme...
Study Of Mechanical Properties Of High Strength Concrete By Partial Replaceme...dbpublications
 

What's hot (18)

Resistance of Fly Ash and Silica Fume Based Glass Fiber Reinforced High-Perfo...
Resistance of Fly Ash and Silica Fume Based Glass Fiber Reinforced High-Perfo...Resistance of Fly Ash and Silica Fume Based Glass Fiber Reinforced High-Perfo...
Resistance of Fly Ash and Silica Fume Based Glass Fiber Reinforced High-Perfo...
 
D1303021317
D1303021317D1303021317
D1303021317
 
Ijetr042328
Ijetr042328Ijetr042328
Ijetr042328
 
Cracking tendency of alkali-activated slag concrete
Cracking tendency of alkali-activated slag concreteCracking tendency of alkali-activated slag concrete
Cracking tendency of alkali-activated slag concrete
 
The environmental impacts of calcium chloride addition to cement on reinforci...
The environmental impacts of calcium chloride addition to cement on reinforci...The environmental impacts of calcium chloride addition to cement on reinforci...
The environmental impacts of calcium chloride addition to cement on reinforci...
 
Paper publication in international journal
Paper publication in international journalPaper publication in international journal
Paper publication in international journal
 
Study on the fire resistant design of reinforced concrete flexural members
Study on the fire resistant design of reinforced concrete flexural membersStudy on the fire resistant design of reinforced concrete flexural members
Study on the fire resistant design of reinforced concrete flexural members
 
Strength and durability studies on silica fume modified high volume fly ash c...
Strength and durability studies on silica fume modified high volume fly ash c...Strength and durability studies on silica fume modified high volume fly ash c...
Strength and durability studies on silica fume modified high volume fly ash c...
 
Effect of sulfate on the properties of self compacting concrete 2
Effect of sulfate on the properties of self compacting concrete 2Effect of sulfate on the properties of self compacting concrete 2
Effect of sulfate on the properties of self compacting concrete 2
 
Corrosion resistance performance of fly ash blended cement concretes
Corrosion resistance performance of fly ash blended cement concretesCorrosion resistance performance of fly ash blended cement concretes
Corrosion resistance performance of fly ash blended cement concretes
 
ACIMaterialsJournalV97(5)
ACIMaterialsJournalV97(5)ACIMaterialsJournalV97(5)
ACIMaterialsJournalV97(5)
 
E0210023027
E0210023027E0210023027
E0210023027
 
20320140504001
2032014050400120320140504001
20320140504001
 
Concrete, Protect The Concrete From Corrosion, IDM8
Concrete, Protect The Concrete From Corrosion, IDM8Concrete, Protect The Concrete From Corrosion, IDM8
Concrete, Protect The Concrete From Corrosion, IDM8
 
COMPRESSIVE STRENGTH AND CARBONATION OF SEA WATER CURED BLENDED CONCRETE
COMPRESSIVE STRENGTH AND CARBONATION OF SEA WATER CURED BLENDED CONCRETE COMPRESSIVE STRENGTH AND CARBONATION OF SEA WATER CURED BLENDED CONCRETE
COMPRESSIVE STRENGTH AND CARBONATION OF SEA WATER CURED BLENDED CONCRETE
 
Microstructure and Abrasive Wear Properties of Chrome Alloy Steel
Microstructure and Abrasive Wear Properties of Chrome Alloy Steel Microstructure and Abrasive Wear Properties of Chrome Alloy Steel
Microstructure and Abrasive Wear Properties of Chrome Alloy Steel
 
Lec02 Material Properties of Concrete and Steel (Reinforced Concrete Design I...
Lec02 Material Properties of Concrete and Steel (Reinforced Concrete Design I...Lec02 Material Properties of Concrete and Steel (Reinforced Concrete Design I...
Lec02 Material Properties of Concrete and Steel (Reinforced Concrete Design I...
 
Study Of Mechanical Properties Of High Strength Concrete By Partial Replaceme...
Study Of Mechanical Properties Of High Strength Concrete By Partial Replaceme...Study Of Mechanical Properties Of High Strength Concrete By Partial Replaceme...
Study Of Mechanical Properties Of High Strength Concrete By Partial Replaceme...
 

Viewers also liked

Viewers also liked (9)

Dispositivos móviles!
Dispositivos móviles!Dispositivos móviles!
Dispositivos móviles!
 
Bitacora
BitacoraBitacora
Bitacora
 
Estacion 2
Estacion 2Estacion 2
Estacion 2
 
Order clerk performance appraisal
Order clerk performance appraisalOrder clerk performance appraisal
Order clerk performance appraisal
 
Redes sociales y videoconferencia
Redes sociales y videoconferenciaRedes sociales y videoconferencia
Redes sociales y videoconferencia
 
CERTIFICACION
CERTIFICACIONCERTIFICACION
CERTIFICACION
 
Top 8 f&b controller resume samples
Top 8 f&b controller resume samplesTop 8 f&b controller resume samples
Top 8 f&b controller resume samples
 
01 - MANSO E SUAVE
01 - MANSO E SUAVE01 - MANSO E SUAVE
01 - MANSO E SUAVE
 
google
googlegoogle
google
 

Similar to Recurring-as-a-Means-of-Partial-Strength-Recovery-of-Concrete-Subjected-to-Elevated-Temperatures

An Experimental Investigation on Effect of Elevated Temperatures on M35 grade...
An Experimental Investigation on Effect of Elevated Temperatures on M35 grade...An Experimental Investigation on Effect of Elevated Temperatures on M35 grade...
An Experimental Investigation on Effect of Elevated Temperatures on M35 grade...IJERD Editor
 
Petrographic investigation to assess condition of concrete exposed to fire
Petrographic investigation to assess condition of concrete exposed to firePetrographic investigation to assess condition of concrete exposed to fire
Petrographic investigation to assess condition of concrete exposed to fireIRJET Journal
 
International Journal of Engineering Research and Development
International Journal of Engineering Research and DevelopmentInternational Journal of Engineering Research and Development
International Journal of Engineering Research and DevelopmentIJERD Editor
 
Study of mechanical properties of concrete at
Study of mechanical properties of concrete atStudy of mechanical properties of concrete at
Study of mechanical properties of concrete ateSAT Publishing House
 
Fire effects on concrete
Fire effects on concreteFire effects on concrete
Fire effects on concreteKhattar Aoun
 
As32709714
As32709714As32709714
As32709714IJMER
 
An Experimental Study on Structural Grade Concrete Using Multi Mineral Admixt...
An Experimental Study on Structural Grade Concrete Using Multi Mineral Admixt...An Experimental Study on Structural Grade Concrete Using Multi Mineral Admixt...
An Experimental Study on Structural Grade Concrete Using Multi Mineral Admixt...IJERD Editor
 
IRJET- Review on High Temperature Concrete using Shockwave Application
IRJET- Review on High Temperature Concrete using Shockwave ApplicationIRJET- Review on High Temperature Concrete using Shockwave Application
IRJET- Review on High Temperature Concrete using Shockwave ApplicationIRJET Journal
 
IRJET- Review on High Temperature Concrete using Shockwave Application
IRJET- Review on High Temperature Concrete using Shockwave ApplicationIRJET- Review on High Temperature Concrete using Shockwave Application
IRJET- Review on High Temperature Concrete using Shockwave ApplicationIRJET Journal
 
Concrete at Elevated Temp
Concrete at Elevated TempConcrete at Elevated Temp
Concrete at Elevated TempJaganGowda2
 
The behavior of hybrid reinforced concrete after heat resistance
The behavior of hybrid reinforced concrete after heat resistanceThe behavior of hybrid reinforced concrete after heat resistance
The behavior of hybrid reinforced concrete after heat resistanceIJERA Editor
 
Corrosion resistance performance of fly ash blended cement concretes
Corrosion resistance performance of fly ash blended cement concretesCorrosion resistance performance of fly ash blended cement concretes
Corrosion resistance performance of fly ash blended cement concreteseSAT Journals
 
Concrete properties
Concrete propertiesConcrete properties
Concrete propertiesKemira Gao
 
IRJET - Effect of Silica Fume on Properties of Concrete-A Review
IRJET -  	  Effect of Silica Fume on Properties of Concrete-A ReviewIRJET -  	  Effect of Silica Fume on Properties of Concrete-A Review
IRJET - Effect of Silica Fume on Properties of Concrete-A ReviewIRJET Journal
 
MECHANICAL PROPERTIES OF HIGH VOLUME FLY ASH CONCRETE SUBJECTED TO ELEVATED ...
MECHANICAL PROPERTIES OF HIGH VOLUME FLY ASH CONCRETE  SUBJECTED TO ELEVATED ...MECHANICAL PROPERTIES OF HIGH VOLUME FLY ASH CONCRETE  SUBJECTED TO ELEVATED ...
MECHANICAL PROPERTIES OF HIGH VOLUME FLY ASH CONCRETE SUBJECTED TO ELEVATED ...Umer Farooq
 
Effect of silica fume on the strength of cement mortar
Effect of silica fume on the strength of cement mortarEffect of silica fume on the strength of cement mortar
Effect of silica fume on the strength of cement mortareSAT Journals
 
AASC-PlacedLargeColumn
AASC-PlacedLargeColumnAASC-PlacedLargeColumn
AASC-PlacedLargeColumnfrank collins
 

Similar to Recurring-as-a-Means-of-Partial-Strength-Recovery-of-Concrete-Subjected-to-Elevated-Temperatures (20)

An Experimental Investigation on Effect of Elevated Temperatures on M35 grade...
An Experimental Investigation on Effect of Elevated Temperatures on M35 grade...An Experimental Investigation on Effect of Elevated Temperatures on M35 grade...
An Experimental Investigation on Effect of Elevated Temperatures on M35 grade...
 
I012126670
I012126670I012126670
I012126670
 
Petrographic investigation to assess condition of concrete exposed to fire
Petrographic investigation to assess condition of concrete exposed to firePetrographic investigation to assess condition of concrete exposed to fire
Petrographic investigation to assess condition of concrete exposed to fire
 
International Journal of Engineering Research and Development
International Journal of Engineering Research and DevelopmentInternational Journal of Engineering Research and Development
International Journal of Engineering Research and Development
 
Study of mechanical properties of concrete at
Study of mechanical properties of concrete atStudy of mechanical properties of concrete at
Study of mechanical properties of concrete at
 
Fire effects on concrete
Fire effects on concreteFire effects on concrete
Fire effects on concrete
 
As32709714
As32709714As32709714
As32709714
 
Fire concrete-struc-sei-08
Fire concrete-struc-sei-08Fire concrete-struc-sei-08
Fire concrete-struc-sei-08
 
Ijciet 10 02_098
Ijciet 10 02_098Ijciet 10 02_098
Ijciet 10 02_098
 
An Experimental Study on Structural Grade Concrete Using Multi Mineral Admixt...
An Experimental Study on Structural Grade Concrete Using Multi Mineral Admixt...An Experimental Study on Structural Grade Concrete Using Multi Mineral Admixt...
An Experimental Study on Structural Grade Concrete Using Multi Mineral Admixt...
 
IRJET- Review on High Temperature Concrete using Shockwave Application
IRJET- Review on High Temperature Concrete using Shockwave ApplicationIRJET- Review on High Temperature Concrete using Shockwave Application
IRJET- Review on High Temperature Concrete using Shockwave Application
 
IRJET- Review on High Temperature Concrete using Shockwave Application
IRJET- Review on High Temperature Concrete using Shockwave ApplicationIRJET- Review on High Temperature Concrete using Shockwave Application
IRJET- Review on High Temperature Concrete using Shockwave Application
 
Concrete at Elevated Temp
Concrete at Elevated TempConcrete at Elevated Temp
Concrete at Elevated Temp
 
The behavior of hybrid reinforced concrete after heat resistance
The behavior of hybrid reinforced concrete after heat resistanceThe behavior of hybrid reinforced concrete after heat resistance
The behavior of hybrid reinforced concrete after heat resistance
 
Corrosion resistance performance of fly ash blended cement concretes
Corrosion resistance performance of fly ash blended cement concretesCorrosion resistance performance of fly ash blended cement concretes
Corrosion resistance performance of fly ash blended cement concretes
 
Concrete properties
Concrete propertiesConcrete properties
Concrete properties
 
IRJET - Effect of Silica Fume on Properties of Concrete-A Review
IRJET -  	  Effect of Silica Fume on Properties of Concrete-A ReviewIRJET -  	  Effect of Silica Fume on Properties of Concrete-A Review
IRJET - Effect of Silica Fume on Properties of Concrete-A Review
 
MECHANICAL PROPERTIES OF HIGH VOLUME FLY ASH CONCRETE SUBJECTED TO ELEVATED ...
MECHANICAL PROPERTIES OF HIGH VOLUME FLY ASH CONCRETE  SUBJECTED TO ELEVATED ...MECHANICAL PROPERTIES OF HIGH VOLUME FLY ASH CONCRETE  SUBJECTED TO ELEVATED ...
MECHANICAL PROPERTIES OF HIGH VOLUME FLY ASH CONCRETE SUBJECTED TO ELEVATED ...
 
Effect of silica fume on the strength of cement mortar
Effect of silica fume on the strength of cement mortarEffect of silica fume on the strength of cement mortar
Effect of silica fume on the strength of cement mortar
 
AASC-PlacedLargeColumn
AASC-PlacedLargeColumnAASC-PlacedLargeColumn
AASC-PlacedLargeColumn
 

Recurring-as-a-Means-of-Partial-Strength-Recovery-of-Concrete-Subjected-to-Elevated-Temperatures

  • 1.  Abstract—Concrete is found to undergo degradation when subjected to elevated temperatures and loose substantial amount of its strength. The loss of strength in concrete is mainly attributed to decomposition of C-S-H and release of physically and chemically bound water, which begins when the exposure temperature exceeds 100°C. When such a concrete comes in contact with moisture, the cement paste is found rehydrate and considerable amount of strength lost is found to recover. This paper presents results of an experimental program carried out to investigate the effect of recuring on strength gain of OPC concrete specimens subjected to elevated temperatures from 200°C to 800°C, which were subjected to retention time of two hours and four hours at the designated temperature. Strength recoveries for concrete subjected to 7 designated elevated temperatures are compared. It is found that the efficacy of recuring as a measure of strength recovery reduces with increase in exposure temperature. Keywords—Elevated Temperature, Recuring, Strength Recovery, Compressive strength. I. INTRODUCTION ONCRETE is a very popular construction material and it finds its application in almost all the civil engineering disciplines. It’s characteristics such as mouldability and high compressive strength has made it a versatile building material. Concrete offers good resistance to heat because of its low conductivity and incombustible nature and further, no toxic fumes are emitted from concrete surface when it is heated. Because of all these characteristics concrete can be rated as the best building material as far as resistance to elevated temperature is concerned The concrete basically consists of two phases, the aggregate phase and the hardened cement paste phase. There is a thermal incompatibility between the aggregate phase and hardened paste phase which initializes the cracking process when the concrete is heated [1]. The cement paste begins to the dehydrate at about 110°C [2] and as the temperature rises above 300°C there will be subsequent decomposition of Ca(OH)2 and the calcium silicate hydrates as the temperature progresses above 600°C [3]. The tendency of aggregates is to expand due to high temperature before disintegration. This differential thermal expansion between aggregates and cement paste leads to Shree Laxmi Prashant, Asst Prof., is with the Department of Civil Engineering, MIT Manipal, Udupi 576104 (e-mail: shrilaxmi.civil@gmail.com). Subhash C. Yaragal and K. S. Babu Narayan are Professors with the Department of Civil Engineering, National Institute of Technology Karnataka, Surathkal, Srinivasnagar-575025, Mangalore, India (e-mail: subhashyaragal@yahoo.com, shrilalisuta@gmail.com). surface crazing which further leads to deeper cracking [4]. Aggregate stability has a major influence on performance of concrete at elevated temperature and the deterioration [5], [6]. The differential thermal expansion combined with decomposition of CSH gel leads to deterioration of ITZ, which is one of the major causes of deterioration of concrete strength [7], [8]. Whenever structural concrete is subjected to elevated temperatures its effects can be visualized in the form of surface cracking, spalling, and disintegration that render the concrete structure unserviceable. The damaged concrete surface is usually repaired by removing the weak layers of concrete (or where the cement paste has lost significant amount of binding property) and their replacement with fresh concrete. But studies conducted by [8], indicate any thermally damaged concrete has the tendency to recover the lost strength by rehydration whenever the concrete is exposed to moist environment. In their studies they found the concrete to recover almost 80% of its original strength in the span of about 12 months. Studies on similar lines were carried out by [9], wherein the thermally deteriorated concrete were subjected to air and water curing. It was found that if the thermally exposed concrete is given constant moisture supply the concrete rehydrates itself to recover the strength and durability. The strength deterioration of concrete is attributed to the coarsening of pore structure and opening of the capillaries, due to dehydration of the gel, that were initially filled by the hydration products. When moisture is supplied to such concrete partial rehydration of cement paste will take place and the capillaries created due the elevated temperature exposure will be refilled by rehydration process [10]. This rehydration is expected to result in regain of certain amount of its lost original strength. The compressive strength of certain cement pastes does not reduce much even up to 500°C or higher [11]. This paper presents the results of the effect of 7, 14, 28 and 56 days of water recuring of thermally deteriorated OPC concrete cubes (100 mm) on their compressive strength. II.EXPERIMENTAL METHODOLOGY Ordinary Portland Cement 43 grade with brand name ACC was used for preparing the concrete specimens. The chemical composition of the cement is given in Table I. River sand conforming to zone 3 (I.S 383-1970 grading requirements) with specific gravity 2.65 was used. Coarse aggregates with specific gravity 2.77 satisfying I.S 383-1970 [12] grading requirements for graded aggregates were used. The mix proportion is given in Table II. Shree Laxmi Prashant, Subhash C. Yaragal, K. S. Babu Narayan Recurring as a Means of Partial Strength Recovery of Concrete Subjected to Elevated Temperatures C World Academy of Science, Engineering and Technology International Journal of Civil, Environmental, Structural, Construction and Architectural Engineering Vol:9, No:3, 2015 270International Scholarly and Scientific Research & Innovation 9(3) 2015 InternationalScienceIndexVol:9,No:3,2015waset.org/Publication/10000795
  • 2. in ho da el ra te te 20 7° w or sw th (3 re co fo se re ag I Sulph L C Water Ce 0.45 The concrete nto moulds of ours the conc ays under w levated tempe ange was 200 mperature bu mperature tim 0°C/min and °C/min. After the ta were maintaine rder to achie witched off an he interior of t 3 nos.) of sp etained after ex ooled specime or 7, 14, 28 an et on 7th, 14th ecuring. The r gainst the stren T CHEMICAL COM Soluble Silica (% Alumina (%) Iron Oxide (% Lime (%) Magnesium (% Insoluble Residue hur (Sulphur Triox Loss On Ignition Chloride Content TA MIX P ment Fine A 1 1 e was mixed f size 100mm crete cubes w ater. The co erature in an 0°C to 800°C uild up during me gradient flattens grad arget tempera ed at that tem eve thermal nd the specim the furnace re pecimen was xposure to ele ens were then nd 56 days. De h and 28th day residual stren ngth of concre Fig. 1 Time TABLE I MPOSITION OF CEM %) ) %) %) e (%) xide) (%) (%) t (%) ABLE II PROPORTION Aggregate 1.198 in a concret m x 100mm were demoulde oncrete cubes electric oven C at an inter test was as s steepens up dually above ature was rea mperature for steady state mens were left eached room t tested to ev evated temper n immersed in estructive testi y to evaluate th ngth after recu ete at ambient temperature cu MENT 21.6 5 3.7 63.1 0.8 1.8 2.1 2 0.01 Coarse Aggreg 2.23 10mm 0.877 20 2 te mixer and x 100mm. A ed and cured s were subjec n target temp rval of 100°C shown in Fig. p to 400°C 400°C is at ached the spe duration of 2 . The furnac t in the furnac temperature. O valuate the s ratures. The na n water for r ing was done he strength ga uring was co t temperature. urve gate 0mm .046 poured After 24 for 28 cted to perature C. The 1. The around rate of ecimens 2 hrs in ce was ce until One set strength aturally recuring for one ain after mpared alo sub sur rep ch to tar co the ed cra de res str exp co sub co 30 res an Af co str de 7 a am reg 50 cal tem its the the fill I A.Visual Obs Fig. 2 shows ong with the bjected to ele rface cracking ported by prev hanged from n grey (700°C- rget temperat ncrete subjec e surface of dges. However acking after terioration on sulting into su B.Strength D Fig. 3 shows rength ratio, posure to ele nditions) due bsequent reco ncrete subjec 00°C retained spectively. Af nd 300°C expo fter 56 days ncrete recove rength respect The concret terioration of and 14 days, mbient strengt gained 83% 00°C and abov lcium hydroxi mperature of 5 ambient stren e cement pas ereby creating led by new hy III. RESULTS servations s the surface e concrete a evated temper g. Changes re vious research normal (at amb 800°C). Colo ture. Fig. 2 cted to 800°C the cubes, bu r no spalling 700°C and n bond betwe ubstantial loss Fig. 2 Concret Deterioration a s the deterior which is the evated temper e to elevated overy with con cted to an ele about 92 and fter recuring f osed concrete of recuring, ered almost ively. te exposed 25% of its am concrete rega th. After 56 of its ambien ve the cement ide and the C 500°C and abo ngth since aft ste loses its i g large voids ydration produ S AND DISCUSS e of concrete at room tem rature showed eported here hers [3], [11]. bient conditio or changes are also shows C. Cracks are ut were more of edges has 800°C expo een cement p of strength. e exposed to 80 and Recovery ration of stre ratio of reta atures to the d temperature ntinuing recur evated temper d 81 % of the for 7 days th is about 94 an the 200°C a 95% and 85 to 400°C mbient strengt ained about 7 days of recu nt strength. T t paste hydrati SH deteriorat ove the recov fter exposure t interlayer wat s which are v ucts. Partial f SIONS exposed to mperature. Co d colour chan are similar to . The concrete ons) to pink (4 found to dep severe crack distributed a e pronounced taken place. osure signifi aste and aggr 00°C ength (Expres ained strength strength at am e exposure a ring till 56 day rature of 200° eir ambient st e strength of nd 83% respec and 300°C ex 5% of its am suffered st h. After recur 77% and 79% urring, concre The temperat ion products s es. For the ex ery is below 7 to 500°C and ter and bond very difficult filling ability o 800°C oncrete ge and o those e color 400°C) end on king of ll over at the Severe es the regates ssed as h after mbient and its ys. The °C and trength 200°C ctively. xposed mbient trength ring for % of its ete had ture of such as xposure 75% of d above d water t to be of new World Academy of Science, Engineering and Technology International Journal of Civil, Environmental, Structural, Construction and Architectural Engineering Vol:9, No:3, 2015 271International Scholarly and Scientific Research & Innovation 9(3) 2015 InternationalScienceIndexVol:9,No:3,2015waset.org/Publication/10000795
  • 3. hydration products will help in partial recovery of lost strength. Fig. 3 Strength improvement through recuring for concrete subjected to heating for 2 hrs Fig. 4 Strength improvement through recuring for concrete subjected to heating for 4 hrs Concrete exposed to 600°C experienced large deterioration of strength and the residual strength is only about 50%. After recuring the concrete regained 18% of its ambient strength in just 7 days. At the end of 56 days of recuring the residual strength recovered is 66% of its ambient strength. Similarly for 700°C and 800°C the concrete had suffered severe strength loss, on recuring recovered 61% and 52% of its ambient strength. Fig. 4 shows the effect of recuring for the thermally deteriorated concrete exposed to heating for 4 hrs. For the concrete exposed to 400°C the gain in strength was observed but comparatively slower as compared to the concrete exposed to 2 hr heating. For the exposure temperatures of 500°C and 600°C the strength recovery was not very appreciable, while the concrete specimen exposed to 700°C and 800°C were damaged to an extent that they lost their integrity and hence could not be recured. The concrete with exposure duration of 3hr and 4hr recovered about 21 and 34% of the lost strength respectively after recuring for 56 days. IV. CONCLUSIONS 1. Recuring is the most economical and easiest technique to recover the strength lost as a result of elevated temperature exposure. Concrete regains its lost strength because if constant supply of moisture to the dehydrated cement paste. 2. For lower temperature substantial amount of strength is recovered after recuring, for higher temperatures (above 400°C) all the lost strength cannot be recovered because the new hydration products formed as a result of recuring, fill the voids and cracks formed as a result of elevated temperature exposure partially. 3. The rate of strength gain is faster during the initial 7 days of recuirng and later slows down. 4. Recuring capacity of the dehydrated cement paste decreases with the increase in exposure duration. 5. The technique of recuring is significant as it could reduce the expenses required for repair and rehabilation of thermally deteriorated concrete and conserve resources. REFERENCES [1] J P olliver, J C Maso, B Bourdette. “Interfacial Transition Zone in Concrete”. Advanced cement based materials vol.2, pp.30-38, 1995. [2] Y. Xu, Y.L. Wong, C.S. Poon, M. Anson. “Influence of PFA on cracking of concrete and cement paste after exposure to high temperatures”, Cement and Concrete Research vol 33, pp. 2009–2016, 2003. [3] Khoury G A, Majrona C E, Pasavento F Shrefler B A. “Modeling of heated concrete”. Magazine of Concrete Research, 54 vol 77 pp.101, 2002. [4] Arioz O. “Effects of elevated temperatures on properties of concrete” Fire Safety Journal vol 42, pp. 516-522, 2007. [5] B. Georgali, P. E. Tsakiridis. Microstructure of fire-damaged concrete. A case study Cement & Concrete Composites 27, 2005 255–259. [6] D Campbell Allen,P M Desai. Influence of aggregate on behavior of concrete at elevated temperatures, Nuclear Engineering and Design, 6, August 1967, Pages 65-77. [7] S C Chakrabarti, K N Sharma and Abha Mittal, ‘Residual strength in concrete after exposure to elevated temperature, The Indian Concrete Journal, Dec 1994 713-717. [8] Chi-Sun Poon, Salman Azhar, Mike Anson, Yuk-Lung Wong, “Strength and durability recovery of fire-damaged concrete after post-fire- curing”,Cement and Concrete Research, Volume 31, Issue 9, September 2001, Pages 1307-1318. [9] C. Alonso, L. Fernandez. “Dehydration and rehydration processes of cement paste exposed to high temperature environments”, Journal of Materials Science vol 39 pp.3015 – 3024, 2004. [10] Gabriel A. Khoury and Patrick J. E. Sullivan, ‘Research at Imperial College on the Effect of Elevated Temperatures on Concrete’, Fire Safety Journal, vol-13, pp.69 – 72, 1988. [11] Yuzer, Nabi , Fevziye Akoz, Leyla Dokuzer O zturk, “Compressive strength–color change relation in mortars at high temperature”, Cement and Concrete Research vol- 34 pp.1803–1807, 2004. [12] IS: 383-1970 "Specifications for coarse and fine aggregates from natural sources for concrete", Bureau of Indian Standards, New Delhi.   0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 0 20 40 60 Strength Ratio Recuring days 200 300 400 500 600 700 800 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 0 7 14 21 28 35 42 49 56 StrengthRatio Recuring (days) 200 300 400 500 600 World Academy of Science, Engineering and Technology International Journal of Civil, Environmental, Structural, Construction and Architectural Engineering Vol:9, No:3, 2015 272International Scholarly and Scientific Research & Innovation 9(3) 2015 InternationalScienceIndexVol:9,No:3,2015waset.org/Publication/10000795