[2024]Digital Global Overview Report 2024 Meltwater.pdf
Ecovap 200 kg elettrico - Ecovap 200 kg electric
1. E
MATERIAL
MATERIALE
SCALE
SCALA
Kg/mm²
HRC
mm
PESO
WEIGHT
TREATMENT
DATA
DATE
CONTROLLATO
CONTROLLED
DATA
DATE
DISEGNATO
DRAWN
UNI
A2
FOGLIO / SHEET
Documento riservato a termini di legge con divieto di riproduzione e divulgazione / Legally private document. All rights reserved
LUNGH. ANGOLI SMUSSI RAGGI
LENGTH ANGLES BEVELS RADIUS
UNI-ISO 2768 m
Kg
TOLLERANZE / TOLERANCES RESISTENZA STRENGTH
TRATTAMENTO
DUREZZA HARDNESS
ALBERI
SHAFTS h13
PROFONDITA' DEPTH
FORI
HOLES H13
DENOMINAZIONE
DENOMINATION
SOSTITUISCE IL
REPLACE THE CODICE
CODESOSTITUITO DAL
REPLACED FROM
C
B
A
IND. MODIFICA / MODIFICATION DATA / DATE SIGLA / NAME
13,3 201
380
240
2EV
17.2
32
III
200
ATM
1
-10/+105-40/+120
28,6
20
kg/h
bar
TARATURA VAL. SIC.
SAFETY VAL. SET PRES.
kW
POTENZA
POWER
V
TENSIONE
VOLTAGE
2FLUIDO
FLUID
VOLUME
CAPACITY
V l lV
TEMPERATURA MIN/ MAX
TEMPERATURE MIN/MAX
TS °C °CTS
PRESSIONE DI PROVA
TEST PRESSURE
PT bar barPT
bar
LATO ACQUA
WATER SIDE
PSbar
LATO GAS
GAS SIDE
PS
PRESSIONE MAX AMMISS.
MAX ALLOW PRESSURE
Kg
PESO
WEIGHT
ANNO
YEAR
PED CAT.
N.F.
SERIAL N.
TIPO
TYPE
PORTATA
FLOW RATE
HEATER ACC. DIR. 2014/34/UE ATEX II 3 G T5
VAPORIZZATORE GPL - LPG VAPORIZER
0948
PEGORARO GAS TECHNOLOGIES S.R.L., VIA ENRICO FERMI, 253, 36100 VICENZA (VI), ITALY
GAS INNOVATIVE TECHNOLOGIES
PEGORARO
Ex
Voltage ON
Heater ON
Heater Allarm
General Switch
Low water level
ON/OFF Button
ELECTRIC PANEL IP 65
1064235
1300
1705
660
1350±1
100
GAS OUT
LPG IN
DN25
#300DN25
#300
DN25
#300
160500550
H2O Sensing line
Gas Sensing line
27 24
374 410
784
310
12
600
560
846
350
634
1
8
2
10
11
12
9 9 4 3
6
7
5
**LIVELLOSTATO (12) OPZIONALE
LEVEL SWITCH (12) OPTIONAL
DATI DI PROGETTO/DESIGN DATA
Portata/Flow rate 200 Kg/h
Pressone di progetto/Design pressure 20 bar
Pressione massima in ingresso/ Max inlet Pressure 17.2 bar
TS lato gas/TS gas side -40/+120 °C
TS lato acqua/TS water side -10+105 °C
Peso/Weight 240 Kg
CALIBRATION
Sensore temperatura H2O/H2O sensing line 50 °C
Sensore temperatura Gas/Gas sensing line 26 °C
Valvola di blocco di minima/Min. Slut shut valves Bar
Valvola di sicurezza/Safety valve 17.2 Bar
PED Certificated: III
36100 VICENZA (VI) ITALY
Tel. +39 0444289382
www.pegorarogas.com
S.C.
1 /
Z:4_UFFICIO TECNICO-R&D10_SW36_Vaporizzatori per gpl36040044_Ecovap 200E 16+16 380V_External Use
00
1:10 M.Z.
36040044
VAPORIZZATORE GPL ELETTRICO 16+16KW 380V
3PH ECOVAP 200Kg/h - ELECTRIC LPG VAPORIZER
16+16KW 380V 3PH ECOVAP 200Kg/h
11/03/2019
1