EL1000 Mach 3 Tech Sheet
 Balboa Instruments
 System PN 54386-04

 System Model # E1P-EL1000M3-DCAH
 Software Version # 32
 EPN # 2833
 Base PCBA – PN 54387-04
 PCB EL1000 – PN 22952 Rev B or C
 HEX File – 10010432

 Base Panels
 ML400 – PN 52684




 Template used: 40572-v32_A.pdf 04/16/2008
 54386-04_97_A.pdf 04/30/2008



http://www.MyPoolSpas.com                    Wholesale Pool and Spa Parts
                                                       Page 1               920-925-3094
                                                                                 54386-04_97_A
System Revision History
System PN EPN           Date      Requested By                             Changes Made
54386-02     2130 11.16.2006 Balboa              Software update to v28
54386-03     n/a  07.25.2007 Balboa              Software update to v30
54386-04     2833 04.30.2008 Balboa              Software update to v32




      http://www.MyPoolSpas.com             Wholesale Pool and Spa Parts
                                                      Page 2                              920-925-3094
                                                                                               54386-04_97_A
Basic System Features and Functions

Power Requirements
  240VAC, 60Hz, 40A, Class A GFCI-protected service (Circuit Breaker rating = 50A max.)



System Outputs
Setup 1 (As Manufactured)




Additional Options



  Connects to Main Panel terminal J70 or J71                    J2                                   K1
                                                                                                            1   P1 LO   2 ALRM 3
                                                                                                                                                     K12   W9
                                                                           G




                                                          W13
                                                                                                                        J96

  Connects to Remote terminal J20
                                                                                 J39




                                                                                                                                       U4
                                                                                 AUX. PANELS




  Connects to terminal J9
                                                                                 J10




                                                                                                                                               J80
                                                                                 J70
                                                                                 MAIN PANELS




                                                                                                                   J69                       J20




                                                                                                      ADCM                         REMOTE
                                                                                 J71




  Connects to A.V. terminal J2                                       J4    J17                 J15    J83
                                                                                                                        J22         J24       J82


                                                      A              EXT   TST          AUX. F        CFG           SENS. A        SENS. B    VAC



      http://www.MyPoolSpas.com              Wholesale Pool and Spa Parts
                                                       Page 3                                                                                                   920-925-3094
                                                                                                                                                                     54386-04_97_A
Persistent Memory and Powering Up
Any time you change DIP Switches or Software Configuration Settings that                  message on power up:
affect parameters the user can change (any filter settings, set temperature        If “      ” appears before (and instead of) “ ” or
default, Celsius vs Fahrenheit, 12-hour vs 24-hour time, reminders                 “                      ”, you have not configured DIP Switches and/or
suppression, etc), you must reset Persistent Memory for your DIP Switch or         Software Configuration Settings in a valid manner. This must be corrected
Software Configuration Settings changes to take effect. You should also reset      before you can reset Persistent Memory.
Persistent Memory after loading a new file into a board (using the ESM,            The switch numbers, jumpers, or configuration settings displayed after
purchased seperately).                                                             “       ” are ones with which the system has found a configuration problem.
                                                                                   For example:
To reset Persistent Memory:                                                             “                  ” would mean that the combination of how you’ve set
     Power down.                                                                        A5 and how you’ve set B2 is not supported on this system.
     Set A12 ON (See illustration below).                                               “               ” would mean that there is a problem with jumper J99
     Power up.                                                                          “                       ” would mean that the combination of how
     Wait until “ ” or “                       ” is displayed on your panel.            you’ve set pump 3 for 1-speed and blower for 1-speed is not supported
     Note: If “      ” appears see section below.                                       on this system.
     Set A12 OFF. (This can be done safely with power on if you use a non-              “                      ” would mean that the combination of how you’ve
     conductive tool such as a pencil to push the switch back to the OFF                set DIP switches which have been assigned to pump 3 and blower is not
     position. Otherwise, power down before setting A12 OFF)                            supported on this system.
     Power up again (if you powered down in the previous step).
     For all other power ups, leave A12 OFF.                                       Power Up Display Sequence
                                                                                   Upon power up, you should see the following on the display:
About Persistent Memory and Time of Day Retention:                                    Three numbers in a row, which are the SSID (the System Software
This system uses memory that doesn’t require a battery to store a variety             ID). The third display of these numbers is the Software Version, which
of settings. What we refer to as Persistent Memory stores all the User                should match the version of your system. For example, if these three
Preferences, as well as all the filter settings, the set temperature, and the         numbers are                      , that is a Mach 3 EL8000 at version 26.
heat mode.                                                                            If there is a Configuration Error, the         message (see above) will
                                                                                      appear at this point (and none of the messages below will display).
Persistent Memory is not used for Time of Day. Time of Day needs to be                Otherwise what comes next is:
“kept running” (not just stored) while the power is off, so a separate Real           An indication of either the input voltage detected (EL1000/EL2000), or
Time Clock feature (on all models except the EL1000) keeps track of                   the heater wattage range supported (EL8000/GL2000/GL8000).
Time of Day while the unit is off. Time of Day Retention, and Time of Day                 Heater wattage display: “ ” means the system supports a heater
Retention alone, is controlled by the J91 jumper. J91 must be set according               from 1 kW to 3 kW. “          ” means the system supports a heater
to main system panel used.                                                                from 3 kW to 6 kW. “          ” means the system supports a 3 kW
                                                                                          heater only. (These ranges may be modified slightly in the case of
                Switchbank A                               Switchbank B
                                                                                          special heaters, which the next bullet covers.)
                                                                                          Input voltage display: A system showing “           ” supports 3 kW
                                                                                          to 6 kW heaters. A system showing “ ” supports the very same
                                                                                          heaters, although at 120V those heaters will function at only 1/4 of
                                                                                          their 240V rated wattage. (The system shows only either “           ” or
                   J91                      J91                                           “      ” as a general indication of input voltage; it does not show the
            RTC                      RTC
         Enabled                 Disabled                                                 actual input voltage.)
  (Not Jumpered)              (Jumpered)                                              If your system is using a special type of heater, a display such as “      ”
                                                                                      may appear next. If your system is using the generic Balboa heater, no
                                                                                      heater type display will appear.
                                                                                      “ ” or “                           ” will appear to signal the start of
                                                                                      Priming Mode.

                                                                                   At this point, the power up sequence is complete. Refer to the User Guide
                                                                                   for the ML Series panel on your system for information about how the spa
                                                                                   operates from this point on.

          http://www.MyPoolSpas.com                               Wholesale Pool and Spa Parts
                                                                            Page 4                                                     920-925-3094
                                                                                                                                            54386-04_97_A
Wiring Configuration and DIP Settings
                       Setup 1 (As Manufactured)




                                                                                                                                                                                                                    FUSE 3A 250V
              CLASS G             FUSE 30A                          J11   J8                       K4   J1                       K11                                          F10 FUSE 10A 250V                                              F4
                                                          F7




                                                                                                                                                                                                                                                                                                           W
                                                                                                                                                                                                                                                                                                         Light
                                                                                                                                                                                                                                1
                                                                                                                                                                                                                                    12V Light




                                                                                                                                                                                                                                                                                                         Spa
                                                                                                                                                                                                                                          BLK
                                                                                                                                                                                                                                                                                                                 J12




                                                                                                                                                                                                                                                  J37
                                                                                                                                                                                                                              2
                                                                                                                     R
                                                                                                                 2-Spd P1




                                                                                                                                                                                                                R




                                                                                                                                                                                                                                                                                                           W
                                                                                                                                                                                                                                                                           J95
                                                                                                                                                                                                                                          12V-B
                                                                 BLK AC                                                                                                       J3       J9




                                                                                                                                                          24HR
                                                                                                                                             Ozone            3                                                               3
                                                                                                                     B




                                                                                                                                                                                                                                          1
                                                                                                                                                                                                                B
                                                                                                                                                                                                    W7                                                                                             J
                                                                                                                                                                                                                                                                                                   J86
                                                 WHT AC                                                                                      24hrs            2




                                                                                                                                                                                                                                             J6
                                                                                                                                                                                        R
                                                                                                                                                          P1-LO




                                                                                                                                                                                                                                                                           J85
                                                                                                                     W




                                                                                                                                                                                                                W
                                                                                                                                                                                                                                             K1                                                    K12




                                                                                                                                                                                     Ozone
                                                                                                                                                                  1
                                                                                                                                                                                                          J2                                                                                              W9




                                                                                                                                                                                        B
                                                                                                                                                                                                                                                         1           2 ALRM 3
                                                                                                        W1




                                                                                                                                                                                                                                                             P1 LO        M




                                                                                                                                                                               J97
                                                                                                                     G




                                              J19 J28 J43 J42 J48




                                                                                                                                                                                                                G
                                        J23
                                                                                                                                                                                                    W13                                                                          J96




                                                                                                                                                                                        W
                                                                                   F2
                              NEUTRAL
                               WHITE




                                                                               FUSE 0.3A 250V
                                                                                                                                             T1
                                                                                                                                                                                                                                                         K12 runs




                                                                                                                                                                                        G




                                                                                                                                                                                                                      J39
                                                                                                                                                                                                                                                         with P1 Low
                                                                                                                                                                                                                                                                  U4
                                                                                                                                                            J5




                                                                                                                                                                                                                      AUX. PANELS
                                                                                                                                                          12V-A
                              BLACK
                               HOT




TORQUE




                                                                                                                                                                                                                      J10
RANGE
                              RED
                              HOT




FOR TB1:                                                                                                                                                                                                                                                                                     J80




                                                                                                                                                                                                                      J70
27-30 IN. LBS.
                                                                                                   K8
  K7                                    TB1




                                                                                                                                                                                                                      MAIN PANELS
                                                                                                                                                                                                                                                                J69                        J20
                                              J53 J54 J55
                                                                                                                            F1

                                                                                                   K6
                                               J25 J26
                                                 RED AC                                                                                                                                                                                            ADCM                          REMOTE
                                                                                                                                                                                                                      J71




                                                                                                                                       K13
                     Balboa                                                                                                                                                                                J4   J17                 J15            J83
                                                                                                                                                                                                                                                                     J22          J24       J82
                                                                                                                                                                      E.GND




       Pb
            EL1000 Mach III
            P/N 22952 REV C
                                COPYRIGHT 2005
                                MADE IN U.S.A.
                                                               5.5 kW
                                                               HTR2                         HTR1

                                                                                                                                                                                                          EXT   TST          AUX. F                CFG           SENS. A         SENS. B    VAC
                                                                                                                                                                                     SWITCHBANK A




WARNING: Main Power to system should be turned OFF BEFORE adjusting DIP switches.
WARNING: Persistent Memory (A12) must be RESET to allow new DIP switch settings to take effect. (See Persistent Memory page)

                                                                                                                                                                                   SSID #                       Wiring Color Key
                                                                               When the Logic Jumper is not installed on J83 (CFG),
                                                                               DIP Switch Settings are enabled.                                                                      100
                                                                                                                                                                                                                                                                        120 Volt Connections
                                                                                                                                                                                     104
                                                                               DIP Switches will then operate as shown below.
                TST AUX. F                     CFG          SENS. A                                                                                                                   32                                                                                240 Volt Connections
                                                                                                                                                                                                                                                                        Black AC Jumpers
                                              Switchbank A                                                         J3                                 J37                                                                                                               12 Volt Connections
                                                                                                             3                                        1                                                                                                                 Relay Control Wires
                                                                                                                                   Circ/Ozone
                                                                                                             2
                                                                                                                                   24hrs      2                                                                 Board Connector Key
                                                                                                                                                                                   12 V
                                                                                                             1                                        3
                                                                                                                                                                                   Light                        1                             Typically Line voltage
             A1, Test Mode OFF                                 A7, Cleanup Cycles OFF                                                                                                                           2                             Typically Line voltage for 2-speed pumps
             A2, Low Amp
                 High Amp                                      A8, Pump 2 Disabled                                                     1          2         3                                                   3                             Neutral (Common)
             A3, Filter by Time
                           Duration                            A9, No Circ Pump
                                                                                                                            J96                                                                                 4                             Ground
             A4, 12 Hr Time                                    A10, Blower Disabled
             A5, Degrees F                                     A11, Do Not Use                                          K12 runs                                                                                                              Note flat sides in connector
             A6, Short Timeouts                                A12, Memory ON                                           per J3
                    http://www.MyPoolSpas.com                                                                Wholesale Pool and Spa Parts
                                                                                                                       Page 5                                                                                                                                                    920-925-3094
                                                                                                                                                                                                                                                                                      54386-04_97_A
DIP Switches and Jumpers Definitions
 WARNING:
  Setting DIP switches incorrectly may cause abnormal system behavior and/or damage to system components.
  Refer to Switchbank illustration on Wiring Configuration page for correct settings for this system.
  Contact Balboa if you require additional configuration pages added to this tech sheet.

DIP Switchbank A Key
A    1 . . . . . . . . . . . . . . . . Test Mode (normally Off)
A    2 . . . . . . . . . . . . . . . . In “ON” position, heater can run while any/all high-speed pumps or blowers are running. (High amperage)
       . . . . . . . . . . . . . . . . In “OFF” position, heater is disabled while any high-speed pump or blower is running. (Low amperage)
A    3 . . . . . . . . . . . . . . . . In “ON” position, filter cycles are programmed by duration
       . . . . . . . . . . . . . . . . In “OFF” position, filter cycles are programmed to start and end times
A    4 . . . . . . . . . . . . . . . . In “ON” position, displays time in 24 hours (military time)
       . . . . . . . . . . . . . . . . In “OFF” position, displays 12 hour time
A    5 . . . . . . . . . . . . . . . . In “ON” position, displays temperature in Celsius
       . . . . . . . . . . . . . . . . In “OFF” position, displays temperature in Fahrenheit
A    6 . . . . . . . . . . . . . . . . In “ON” position, Equipment timeout 30 minutes (4 hours for Pump 1 Low)
       . . . . . . . . . . . . . . . . In “OFF” position, Equipment timeout 15 minutes (2 hours for Pump 1 Low)
A    7 . . . . . . . . . . . . . . . . In “ON” position, Cleanup Cycle – 30 minutes after spa use/timeout, Pump 1 Low & Ozone run for 1 hour.
       . . . . . . . . . . . . . . . . In “OFF” position, no Cleanup Cycle
A    8 . . . . . . . . . . . . . . In “ON” position, enables Pump 2 (A10 must be Off)
       . . . . . . . . . . . . . . . . In “OFF” position, disables Pump 2
A    9 . . . . . . . . . . . . . . In “ON” position, Circ Pump 24 Hours with 3˚F Shut-off. *See note below.
       . . . . . . . . . . . . . . . . In “OFF” position, no Circ Pump
A 10 . . . . . . . . . . . . . . . In “ON” position, Blower enable when Pump 2 is disabled (A8 must be Off)
       . . . . . . . . . . . . . . . . In “OFF” position, Blower disabled
A 11 . . . . . . . . . . . . . . . In “ON” position, DO NOT USE. *See note below.
       . . . . . . . . . . . . . . . . In “OFF” position, Pump 1 is two-speed
A 12 . . . . . . . . . . . . . . . . Persistent memory reset (normally off) (used when spa is powering up)

*Note: For systems with a Circ Pump, software must be v30 or higher and requires X-03 expansion board to be installed. Also, the Ozone
generator, if installed, will be moved to X-03 board.




Jumpers
J3    Jumper on Pins 1 and 2 will power J9 (Ozone) with Pump 1 Low.
      Jumper on Pins 2 and 3 will power J9 to run 24 hours.
J37   Jumper on Pins 1 and 2 will power one leg of J12 (Spa Light) at 120 Volts AC.
      Jumper on Pins 2 and 3 will power one leg of J12 (Spa Light) at 12 Volts AC.
      Note: W9 controls voltage on the other leg of J12 and must be set for the same voltage.
J96   Jumper on Pins 1 and 2 will operate the relay K12 with Pump 1 Low.
      Jumper on Pins 2 and 3 will operate the relay K12 independently.




 http://www.MyPoolSpas.com                           Wholesale Pool and Spa Parts
                                                               Page 6                                                    920-925-3094
                                                                                                                              54386-04_97_A
Ozone Connections
Ozone Connector Voltage: The EL circuit board is factory configured to deliver a preset voltage (120V
or 240V) to the on-board ozone connector (J9). See the ratings table on the wiring diagram attached to
the cover of the enclosure for the configured voltage. For 240V output W13 connects to Red AC and for
120V output W13 connects to White AC.

The voltage to the ozone connector can be changed in the field if required. W13 just needs to be set for
the required voltage.

Balboa Ozone Generator: If the board is set up to operate a 120V ozone generator, the connector on the
ozone generator is likely to be configured correctly, but should be compared to the illustration below.

If a 240V ozone generator is required, be sure the red wire in the ozone cord is positioned in the
connector next to the green ground wire as described below.

Note: A special tool is required to remove the pins from the connector body once they are snapped in
place. Check with your Balboa Account Manager for information on purchasing a pin-removal tool.
Balboa Ozone connector configuration for 120V 60Hz                                                                                                                                                       B
                                              Line - Black conductor
                       Use this slot for the leftover Red conductor
         Common - Install the White conductor here for 120V ozone
                                                                                                                                                                                                                G
                                         Ground (Green) conductor

                                                                                                                                                                                              Flat sides of sockets as shown
Balboa Ozone connector configuration for 240V 60Hz                                                                                                                                                       B
                                              Line - Black conductor
                      Use this slot for the leftover White conductor
           Common - Install the Red conductor here for 240V ozone
                                                                                                                                                                                                                G
                                          Ground (Green) conductor


                                                                                                                                                                                                W13 wire determines voltage
                                                                                            FUSE 3A 250V
J1             K11                                  F10 FUSE 10A 250V                                                   F4
                                                                                                                                                                                   N




                                                                                                           1
                                                                                                                     BLK




                                                                                                                                                                                        J12     Line - Black conductor
                                                                                                                             J37




                                                                                                         2
     R




                                                                                                                                                                                   G
                                                                                                                                                      J95
                                                                                                                     12V-B




                                                    J3       J9
                                                                                                                                                                                                Use this slot for the leftover conductor
                                24HR




                                    3                                                                    3
     B




                                                                          W7                                                                                                 J86
                                    2
                                                                                                                                                                                                Common - Red for 240V or
                                                                                                                        J6
                                P1-LO




                                                                                                                                                      J85
     W




                                                                                           N




                                        1                                       J2                                      K1                                                   K12   W9
                                                                                                                                    1           2 ALRM 3                                           White for 120V ozone (See W13 wire)
W1




                                                                                                                                        P1 LO
                                                     J97
     G




                                                                                           G




                                                                          W13
                                                                                                                                                J96                                             Ground (Green) conductor
                           T1
                                                                                                 J39




                                                                                                                                                               U4
                                  J5
                                                                                                 AUX. PANELS




                                12V-A
                                                                                                 J10




                                                                                                                                                                       J80
                                                                                                 J70
                                                                                                 MAIN PANELS




                                                                                                                                           J69                       J20

          F1




                                                                                                                              ADCM                          REMOTE
                                                                                                 J71




                     K13
                                                                                      J4                       J15                              J22          J24      J82
                                                                                           J17                                J83
                                            E.GND




                                                           SWITCHBANK A              EXT   TST          AUX F                 CFG           SENS A          SENS B    VAC
                http://www.MyPoolSpas.com                                                                                                   Wholesale Pool and Spa Parts
                                                                                                                                                      Page 7                                                                     920-925-3094
                                                                                                                                                                                                                                      54386-04_97_A
Panel Configurations
                   Note: Connects to Main Panel terminal J70 or J71
NON-TIME CAPABLE




                                                             Heat




                                        Jets   Aux                  Temp   Light



                   ML400
                   PN 52684 with Overlay PN 11345




                          http://www.MyPoolSpas.com             Wholesale Pool and Spa Parts
                                                                          Page 8               920-925-3094
                                                                                                    54386-04_97_A

More Related Content

What's hot (10)

54384 04 vsp_vs511_sz_dcah
54384 04 vsp_vs511_sz_dcah54384 04 vsp_vs511_sz_dcah
54384 04 vsp_vs511_sz_dcah
 
54368 03 vsp_vs500_z_ccah
54368 03 vsp_vs500_z_ccah54368 03 vsp_vs500_z_ccah
54368 03 vsp_vs500_z_ccah
 
54517 01 gs5_gs510_sz_rca-30
54517 01 gs5_gs510_sz_rca-3054517 01 gs5_gs510_sz_rca-30
54517 01 gs5_gs510_sz_rca-30
 
55476 vsp vs515_z_ycah
55476 vsp vs515_z_ycah55476 vsp vs515_z_ycah
55476 vsp vs515_z_ycah
 
55991 vsp vs501_z_dcaj
55991 vsp vs501_z_dcaj55991 vsp vs501_z_dcaj
55991 vsp vs501_z_dcaj
 
56016 01 vsp_vs520_dz_ycah
56016 01 vsp_vs520_dz_ycah56016 01 vsp_vs520_dz_ycah
56016 01 vsp_vs520_dz_ycah
 
55106 gs5 gs510_dz_rca_30
55106 gs5 gs510_dz_rca_3055106 gs5 gs510_dz_rca_30
55106 gs5 gs510_dz_rca_30
 
Power injector 1 port power-over-ethernet installation guide
Power injector 1 port power-over-ethernet installation guidePower injector 1 port power-over-ethernet installation guide
Power injector 1 port power-over-ethernet installation guide
 
Variable Frequency Drives
Variable Frequency DrivesVariable Frequency Drives
Variable Frequency Drives
 
Advanced motion controls sx25a20
Advanced motion controls sx25a20Advanced motion controls sx25a20
Advanced motion controls sx25a20
 

Viewers also liked (17)

60hz eng non_m7
60hz eng non_m760hz eng non_m7
60hz eng non_m7
 
85 0100 b universal air installation
85 0100 b universal air installation85 0100 b universal air installation
85 0100 b universal air installation
 
Hotwater products
Hotwater productsHotwater products
Hotwater products
 
54370 03 vsp_vs500_z_ccaj
54370 03 vsp_vs500_z_ccaj54370 03 vsp_vs500_z_ccaj
54370 03 vsp_vs500_z_ccaj
 
85 0135 a-rev 1_installation manual
85 0135 a-rev 1_installation manual85 0135 a-rev 1_installation manual
85 0135 a-rev 1_installation manual
 
54639 01 vsp_vs514_sz_ycah
54639 01 vsp_vs514_sz_ycah54639 01 vsp_vs514_sz_ycah
54639 01 vsp_vs514_sz_ycah
 
40192 a
40192 a40192 a
40192 a
 
55646 vsp vs300_fc5_ccah
55646 vsp vs300_fc5_ccah55646 vsp vs300_fc5_ccah
55646 vsp vs300_fc5_ccah
 
85 0066-d rev 1 hq ultimate dealer guide
85 0066-d rev 1 hq ultimate dealer guide85 0066-d rev 1 hq ultimate dealer guide
85 0066-d rev 1 hq ultimate dealer guide
 
85 0062-j eco-3-installation insert_web
85 0062-j eco-3-installation insert_web85 0062-j eco-3-installation insert_web
85 0062-j eco-3-installation insert_web
 
50hz eng non_m7
50hz eng non_m750hz eng non_m7
50hz eng non_m7
 
85 0076-c 6220 troubleshooting
85 0076-c 6220 troubleshooting85 0076-c 6220 troubleshooting
85 0076-c 6220 troubleshooting
 
53641 0320 gs5_gs510s_rca-30k
53641 0320 gs5_gs510s_rca-30k53641 0320 gs5_gs510s_rca-30k
53641 0320 gs5_gs510s_rca-30k
 
54763 01 gs5_gs523_dz_rca-30
54763 01 gs5_gs523_dz_rca-3054763 01 gs5_gs523_dz_rca-30
54763 01 gs5_gs523_dz_rca-30
 
55067 03 e2_p_el2001m3_ycah
55067 03 e2_p_el2001m3_ycah55067 03 e2_p_el2001m3_ycah
55067 03 e2_p_el2001m3_ycah
 
Sspa 1 and sspa-mp spa packs
Sspa 1 and sspa-mp spa packsSspa 1 and sspa-mp spa packs
Sspa 1 and sspa-mp spa packs
 
Vs 300 fl4 manual
Vs 300 fl4 manualVs 300 fl4 manual
Vs 300 fl4 manual
 

Similar to 54386 04 e1_p_el1000m3_dcah

Similar to 54386 04 e1_p_el1000m3_dcah (20)

56007 01 vsp_vs520_sz_dcah
56007 01 vsp_vs520_sz_dcah56007 01 vsp_vs520_sz_dcah
56007 01 vsp_vs520_sz_dcah
 
54337 0420 vsp_vs500z_fcah
54337 0420 vsp_vs500z_fcah54337 0420 vsp_vs500z_fcah
54337 0420 vsp_vs500z_fcah
 
54337 0420 vsp_vs500z_fcah
54337 0420 vsp_vs500z_fcah54337 0420 vsp_vs500z_fcah
54337 0420 vsp_vs500z_fcah
 
54371 02 vsp_vs510_sz_dcah
54371 02 vsp_vs510_sz_dcah54371 02 vsp_vs510_sz_dcah
54371 02 vsp_vs510_sz_dcah
 
54379 03 vsp_vs501_z_ccaj
54379 03 vsp_vs501_z_ccaj54379 03 vsp_vs501_z_ccaj
54379 03 vsp_vs501_z_ccaj
 
54509 01 gs5_gs500_z_rca-30
54509 01 gs5_gs500_z_rca-3054509 01 gs5_gs500_z_rca-30
54509 01 gs5_gs500_z_rca-30
 
55613 gs5 gs501_z_rca_15
55613 gs5 gs501_z_rca_1555613 gs5 gs501_z_rca_15
55613 gs5 gs501_z_rca_15
 
54481 03 vsp_vs501_z_ccaj
54481 03 vsp_vs501_z_ccaj54481 03 vsp_vs501_z_ccaj
54481 03 vsp_vs501_z_ccaj
 
54382 04 vsp_vs511_z_dcah
54382 04 vsp_vs511_z_dcah54382 04 vsp_vs511_z_dcah
54382 04 vsp_vs511_z_dcah
 
55839 01 vsp_vs513_z_ycah
55839 01 vsp_vs513_z_ycah55839 01 vsp_vs513_z_ycah
55839 01 vsp_vs513_z_ycah
 
55399 gs5 gs501_z_rca_30
55399 gs5 gs501_z_rca_3055399 gs5 gs501_z_rca_30
55399 gs5 gs501_z_rca_30
 
54523 01 gs5_gs500_z_rca-20
54523 01 gs5_gs500_z_rca-2054523 01 gs5_gs500_z_rca-20
54523 01 gs5_gs500_z_rca-20
 
54370 03 vsp_vs500_z_ccaj
54370 03 vsp_vs500_z_ccaj54370 03 vsp_vs500_z_ccaj
54370 03 vsp_vs500_z_ccaj
 
55471 gs5 gs501_z_rca_30
55471 gs5 gs501_z_rca_3055471 gs5 gs501_z_rca_30
55471 gs5 gs501_z_rca_30
 
54762 01 vsp_vs523_dz_ycah
54762 01 vsp_vs523_dz_ycah54762 01 vsp_vs523_dz_ycah
54762 01 vsp_vs523_dz_ycah
 
54356 0320 vsp_vs501z_ccah
54356 0320 vsp_vs501z_ccah54356 0320 vsp_vs501z_ccah
54356 0320 vsp_vs501z_ccah
 
54635 01 vsp_vs503_sz_dcah
54635 01 vsp_vs503_sz_dcah54635 01 vsp_vs503_sz_dcah
54635 01 vsp_vs503_sz_dcah
 
55666 vsp vs525_bcah
55666 vsp vs525_bcah55666 vsp vs525_bcah
55666 vsp vs525_bcah
 
55370 01 vsp_vs504_sz_dcaj
55370 01 vsp_vs504_sz_dcaj55370 01 vsp_vs504_sz_dcaj
55370 01 vsp_vs504_sz_dcaj
 
54637 01 vsp_vs504_sz_dcah
54637 01 vsp_vs504_sz_dcah54637 01 vsp_vs504_sz_dcah
54637 01 vsp_vs504_sz_dcah
 

More from Accurate Pool & Spa Services, llc

More from Accurate Pool & Spa Services, llc (20)

Ultimate spaside instruction sheet
Ultimate spaside instruction sheetUltimate spaside instruction sheet
Ultimate spaside instruction sheet
 
Standard spaside instruction sheet
Standard spaside instruction sheetStandard spaside instruction sheet
Standard spaside instruction sheet
 
Ps 9704 manual-rev1_2
Ps 9704 manual-rev1_2Ps 9704 manual-rev1_2
Ps 9704 manual-rev1_2
 
Ps 7100 manual-rev1_2
Ps 7100 manual-rev1_2Ps 7100 manual-rev1_2
Ps 7100 manual-rev1_2
 
Ps 6500 manual-rev1_2
Ps 6500 manual-rev1_2Ps 6500 manual-rev1_2
Ps 6500 manual-rev1_2
 
Hq label wd highlight
Hq label wd highlightHq label wd highlight
Hq label wd highlight
 
Eco 3 spaside instruction sheet
Eco 3 spaside instruction sheetEco 3 spaside instruction sheet
Eco 3 spaside instruction sheet
 
Eco 2 spaside instruction sheet
Eco 2 spaside instruction sheetEco 2 spaside instruction sheet
Eco 2 spaside instruction sheet
 
Eco 1 spaside instruction sheet
Eco 1 spaside instruction sheetEco 1 spaside instruction sheet
Eco 1 spaside instruction sheet
 
Eco 2 pcb revisions
Eco 2 pcb revisionsEco 2 pcb revisions
Eco 2 pcb revisions
 
Eco 1 programming
Eco 1 programmingEco 1 programming
Eco 1 programming
 
Deluxe spaside instruction sheet
Deluxe spaside instruction sheetDeluxe spaside instruction sheet
Deluxe spaside instruction sheet
 
Cs9700 software upgrade notice 3 07
Cs9700 software upgrade notice 3 07Cs9700 software upgrade notice 3 07
Cs9700 software upgrade notice 3 07
 
Cs9700 llp settings 3 07
Cs9700 llp settings 3 07Cs9700 llp settings 3 07
Cs9700 llp settings 3 07
 
Control cord colors
Control cord colorsControl cord colors
Control cord colors
 
850077 a outdoor operation
850077 a outdoor operation850077 a outdoor operation
850077 a outdoor operation
 
9400 9600 programming
9400 9600 programming9400 9600 programming
9400 9600 programming
 
9300 programming
9300 programming9300 programming
9300 programming
 
85 0138 infrared remote-web
85 0138 infrared remote-web85 0138 infrared remote-web
85 0138 infrared remote-web
 
85 0137 rev 1-palm pilot programming_web
85 0137 rev 1-palm pilot programming_web85 0137 rev 1-palm pilot programming_web
85 0137 rev 1-palm pilot programming_web
 

54386 04 e1_p_el1000m3_dcah

  • 1. EL1000 Mach 3 Tech Sheet Balboa Instruments System PN 54386-04 System Model # E1P-EL1000M3-DCAH Software Version # 32 EPN # 2833 Base PCBA – PN 54387-04 PCB EL1000 – PN 22952 Rev B or C HEX File – 10010432 Base Panels ML400 – PN 52684 Template used: 40572-v32_A.pdf 04/16/2008 54386-04_97_A.pdf 04/30/2008 http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 1 920-925-3094 54386-04_97_A
  • 2. System Revision History System PN EPN Date Requested By Changes Made 54386-02 2130 11.16.2006 Balboa Software update to v28 54386-03 n/a 07.25.2007 Balboa Software update to v30 54386-04 2833 04.30.2008 Balboa Software update to v32 http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 2 920-925-3094 54386-04_97_A
  • 3. Basic System Features and Functions Power Requirements 240VAC, 60Hz, 40A, Class A GFCI-protected service (Circuit Breaker rating = 50A max.) System Outputs Setup 1 (As Manufactured) Additional Options Connects to Main Panel terminal J70 or J71 J2 K1 1 P1 LO 2 ALRM 3 K12 W9 G W13 J96 Connects to Remote terminal J20 J39 U4 AUX. PANELS Connects to terminal J9 J10 J80 J70 MAIN PANELS J69 J20 ADCM REMOTE J71 Connects to A.V. terminal J2 J4 J17 J15 J83 J22 J24 J82 A EXT TST AUX. F CFG SENS. A SENS. B VAC http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 3 920-925-3094 54386-04_97_A
  • 4. Persistent Memory and Powering Up Any time you change DIP Switches or Software Configuration Settings that message on power up: affect parameters the user can change (any filter settings, set temperature If “ ” appears before (and instead of) “ ” or default, Celsius vs Fahrenheit, 12-hour vs 24-hour time, reminders “ ”, you have not configured DIP Switches and/or suppression, etc), you must reset Persistent Memory for your DIP Switch or Software Configuration Settings in a valid manner. This must be corrected Software Configuration Settings changes to take effect. You should also reset before you can reset Persistent Memory. Persistent Memory after loading a new file into a board (using the ESM, The switch numbers, jumpers, or configuration settings displayed after purchased seperately). “ ” are ones with which the system has found a configuration problem. For example: To reset Persistent Memory: “ ” would mean that the combination of how you’ve set Power down. A5 and how you’ve set B2 is not supported on this system. Set A12 ON (See illustration below). “ ” would mean that there is a problem with jumper J99 Power up. “ ” would mean that the combination of how Wait until “ ” or “ ” is displayed on your panel. you’ve set pump 3 for 1-speed and blower for 1-speed is not supported Note: If “ ” appears see section below. on this system. Set A12 OFF. (This can be done safely with power on if you use a non- “ ” would mean that the combination of how you’ve conductive tool such as a pencil to push the switch back to the OFF set DIP switches which have been assigned to pump 3 and blower is not position. Otherwise, power down before setting A12 OFF) supported on this system. Power up again (if you powered down in the previous step). For all other power ups, leave A12 OFF. Power Up Display Sequence Upon power up, you should see the following on the display: About Persistent Memory and Time of Day Retention: Three numbers in a row, which are the SSID (the System Software This system uses memory that doesn’t require a battery to store a variety ID). The third display of these numbers is the Software Version, which of settings. What we refer to as Persistent Memory stores all the User should match the version of your system. For example, if these three Preferences, as well as all the filter settings, the set temperature, and the numbers are , that is a Mach 3 EL8000 at version 26. heat mode. If there is a Configuration Error, the message (see above) will appear at this point (and none of the messages below will display). Persistent Memory is not used for Time of Day. Time of Day needs to be Otherwise what comes next is: “kept running” (not just stored) while the power is off, so a separate Real An indication of either the input voltage detected (EL1000/EL2000), or Time Clock feature (on all models except the EL1000) keeps track of the heater wattage range supported (EL8000/GL2000/GL8000). Time of Day while the unit is off. Time of Day Retention, and Time of Day Heater wattage display: “ ” means the system supports a heater Retention alone, is controlled by the J91 jumper. J91 must be set according from 1 kW to 3 kW. “ ” means the system supports a heater to main system panel used. from 3 kW to 6 kW. “ ” means the system supports a 3 kW heater only. (These ranges may be modified slightly in the case of Switchbank A Switchbank B special heaters, which the next bullet covers.) Input voltage display: A system showing “ ” supports 3 kW to 6 kW heaters. A system showing “ ” supports the very same heaters, although at 120V those heaters will function at only 1/4 of their 240V rated wattage. (The system shows only either “ ” or J91 J91 “ ” as a general indication of input voltage; it does not show the RTC RTC Enabled Disabled actual input voltage.) (Not Jumpered) (Jumpered) If your system is using a special type of heater, a display such as “ ” may appear next. If your system is using the generic Balboa heater, no heater type display will appear. “ ” or “ ” will appear to signal the start of Priming Mode. At this point, the power up sequence is complete. Refer to the User Guide for the ML Series panel on your system for information about how the spa operates from this point on. http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 4 920-925-3094 54386-04_97_A
  • 5. Wiring Configuration and DIP Settings Setup 1 (As Manufactured) FUSE 3A 250V CLASS G FUSE 30A J11 J8 K4 J1 K11 F10 FUSE 10A 250V F4 F7 W Light 1 12V Light Spa BLK J12 J37 2 R 2-Spd P1 R W J95 12V-B BLK AC J3 J9 24HR Ozone 3 3 B 1 B W7 J J86 WHT AC 24hrs 2 J6 R P1-LO J85 W W K1 K12 Ozone 1 J2 W9 B 1 2 ALRM 3 W1 P1 LO M J97 G J19 J28 J43 J42 J48 G J23 W13 J96 W F2 NEUTRAL WHITE FUSE 0.3A 250V T1 K12 runs G J39 with P1 Low U4 J5 AUX. PANELS 12V-A BLACK HOT TORQUE J10 RANGE RED HOT FOR TB1: J80 J70 27-30 IN. LBS. K8 K7 TB1 MAIN PANELS J69 J20 J53 J54 J55 F1 K6 J25 J26 RED AC ADCM REMOTE J71 K13 Balboa J4 J17 J15 J83 J22 J24 J82 E.GND Pb EL1000 Mach III P/N 22952 REV C COPYRIGHT 2005 MADE IN U.S.A. 5.5 kW HTR2 HTR1 EXT TST AUX. F CFG SENS. A SENS. B VAC SWITCHBANK A WARNING: Main Power to system should be turned OFF BEFORE adjusting DIP switches. WARNING: Persistent Memory (A12) must be RESET to allow new DIP switch settings to take effect. (See Persistent Memory page) SSID # Wiring Color Key When the Logic Jumper is not installed on J83 (CFG), DIP Switch Settings are enabled. 100 120 Volt Connections 104 DIP Switches will then operate as shown below. TST AUX. F CFG SENS. A 32 240 Volt Connections Black AC Jumpers Switchbank A J3 J37 12 Volt Connections 3 1 Relay Control Wires Circ/Ozone 2 24hrs 2 Board Connector Key 12 V 1 3 Light 1 Typically Line voltage A1, Test Mode OFF A7, Cleanup Cycles OFF 2 Typically Line voltage for 2-speed pumps A2, Low Amp High Amp A8, Pump 2 Disabled 1 2 3 3 Neutral (Common) A3, Filter by Time Duration A9, No Circ Pump J96 4 Ground A4, 12 Hr Time A10, Blower Disabled A5, Degrees F A11, Do Not Use K12 runs Note flat sides in connector A6, Short Timeouts A12, Memory ON per J3 http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 5 920-925-3094 54386-04_97_A
  • 6. DIP Switches and Jumpers Definitions WARNING: Setting DIP switches incorrectly may cause abnormal system behavior and/or damage to system components. Refer to Switchbank illustration on Wiring Configuration page for correct settings for this system. Contact Balboa if you require additional configuration pages added to this tech sheet. DIP Switchbank A Key A 1 . . . . . . . . . . . . . . . . Test Mode (normally Off) A 2 . . . . . . . . . . . . . . . . In “ON” position, heater can run while any/all high-speed pumps or blowers are running. (High amperage) . . . . . . . . . . . . . . . . In “OFF” position, heater is disabled while any high-speed pump or blower is running. (Low amperage) A 3 . . . . . . . . . . . . . . . . In “ON” position, filter cycles are programmed by duration . . . . . . . . . . . . . . . . In “OFF” position, filter cycles are programmed to start and end times A 4 . . . . . . . . . . . . . . . . In “ON” position, displays time in 24 hours (military time) . . . . . . . . . . . . . . . . In “OFF” position, displays 12 hour time A 5 . . . . . . . . . . . . . . . . In “ON” position, displays temperature in Celsius . . . . . . . . . . . . . . . . In “OFF” position, displays temperature in Fahrenheit A 6 . . . . . . . . . . . . . . . . In “ON” position, Equipment timeout 30 minutes (4 hours for Pump 1 Low) . . . . . . . . . . . . . . . . In “OFF” position, Equipment timeout 15 minutes (2 hours for Pump 1 Low) A 7 . . . . . . . . . . . . . . . . In “ON” position, Cleanup Cycle – 30 minutes after spa use/timeout, Pump 1 Low & Ozone run for 1 hour. . . . . . . . . . . . . . . . . In “OFF” position, no Cleanup Cycle A 8 . . . . . . . . . . . . . . In “ON” position, enables Pump 2 (A10 must be Off) . . . . . . . . . . . . . . . . In “OFF” position, disables Pump 2 A 9 . . . . . . . . . . . . . . In “ON” position, Circ Pump 24 Hours with 3˚F Shut-off. *See note below. . . . . . . . . . . . . . . . . In “OFF” position, no Circ Pump A 10 . . . . . . . . . . . . . . . In “ON” position, Blower enable when Pump 2 is disabled (A8 must be Off) . . . . . . . . . . . . . . . . In “OFF” position, Blower disabled A 11 . . . . . . . . . . . . . . . In “ON” position, DO NOT USE. *See note below. . . . . . . . . . . . . . . . . In “OFF” position, Pump 1 is two-speed A 12 . . . . . . . . . . . . . . . . Persistent memory reset (normally off) (used when spa is powering up) *Note: For systems with a Circ Pump, software must be v30 or higher and requires X-03 expansion board to be installed. Also, the Ozone generator, if installed, will be moved to X-03 board. Jumpers J3 Jumper on Pins 1 and 2 will power J9 (Ozone) with Pump 1 Low. Jumper on Pins 2 and 3 will power J9 to run 24 hours. J37 Jumper on Pins 1 and 2 will power one leg of J12 (Spa Light) at 120 Volts AC. Jumper on Pins 2 and 3 will power one leg of J12 (Spa Light) at 12 Volts AC. Note: W9 controls voltage on the other leg of J12 and must be set for the same voltage. J96 Jumper on Pins 1 and 2 will operate the relay K12 with Pump 1 Low. Jumper on Pins 2 and 3 will operate the relay K12 independently. http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 6 920-925-3094 54386-04_97_A
  • 7. Ozone Connections Ozone Connector Voltage: The EL circuit board is factory configured to deliver a preset voltage (120V or 240V) to the on-board ozone connector (J9). See the ratings table on the wiring diagram attached to the cover of the enclosure for the configured voltage. For 240V output W13 connects to Red AC and for 120V output W13 connects to White AC. The voltage to the ozone connector can be changed in the field if required. W13 just needs to be set for the required voltage. Balboa Ozone Generator: If the board is set up to operate a 120V ozone generator, the connector on the ozone generator is likely to be configured correctly, but should be compared to the illustration below. If a 240V ozone generator is required, be sure the red wire in the ozone cord is positioned in the connector next to the green ground wire as described below. Note: A special tool is required to remove the pins from the connector body once they are snapped in place. Check with your Balboa Account Manager for information on purchasing a pin-removal tool. Balboa Ozone connector configuration for 120V 60Hz B Line - Black conductor Use this slot for the leftover Red conductor Common - Install the White conductor here for 120V ozone G Ground (Green) conductor Flat sides of sockets as shown Balboa Ozone connector configuration for 240V 60Hz B Line - Black conductor Use this slot for the leftover White conductor Common - Install the Red conductor here for 240V ozone G Ground (Green) conductor W13 wire determines voltage FUSE 3A 250V J1 K11 F10 FUSE 10A 250V F4 N 1 BLK J12 Line - Black conductor J37 2 R G J95 12V-B J3 J9 Use this slot for the leftover conductor 24HR 3 3 B W7 J86 2 Common - Red for 240V or J6 P1-LO J85 W N 1 J2 K1 K12 W9 1 2 ALRM 3 White for 120V ozone (See W13 wire) W1 P1 LO J97 G G W13 J96 Ground (Green) conductor T1 J39 U4 J5 AUX. PANELS 12V-A J10 J80 J70 MAIN PANELS J69 J20 F1 ADCM REMOTE J71 K13 J4 J15 J22 J24 J82 J17 J83 E.GND SWITCHBANK A EXT TST AUX F CFG SENS A SENS B VAC http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 7 920-925-3094 54386-04_97_A
  • 8. Panel Configurations Note: Connects to Main Panel terminal J70 or J71 NON-TIME CAPABLE Heat Jets Aux Temp Light ML400 PN 52684 with Overlay PN 11345 http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 8 920-925-3094 54386-04_97_A