ECO-3 SERIES - INCOMING POWER WIRING

All Universal systems leave configured 120-Volt input power (Option 1).


                OPTION 1                                                    OPTION 2




                                        L1 to L2
                                        Jumper


                                IMPORTANT - 3-Wire 240V Systems, DO NOT
                                         Connect Neutral Wire




           L1 N GR                                                        L1 N GR L2

120-Volt electrical service requires:                        240-Volt electrical service requires:

Line 1, Neutral and Ground.                                  Line 1, Lin 2, Neutral and Ground.

(Line 1 to Line 2 jumper must be in place                    (Line 1 to Line 2 jumper must be removed)
for system to operate properly)




IMPORTANT: Always refer to the product data label (located on top of control box) for
specific electrical information.

    http://www.MyPoolSpas.com              Wholesale Pool and Spa Parts                       920-925-3094
ECO-3 LOW LEVEL PROGRAMMING

It is possible to change the parameters of the system by positioning specific jumpers
located on the system board (see illustration below).




JUMPER #1 - CURRENT LIMITING
JUMPER #2 - TEMPERATURE DISPLAY
JUMPER #3 - CIRCULATION PUMP




JUMPER 1 = Current Limiting:

Position 1 - (High Current 240vac): There is no
current restriction. This allows the heater to operate
with the pump in high speed.

Position 2 - (Low Current 120vac): The system will
not turn the heater on when the pump is in high
speed. The heater indicator will flash on the spaside
to tell the user that there is a call for heat but the
heater is not allowed to start.

JUMPER 2 = Temperature Display:

Position 1 - Fahrenheit Degrees

Position 2 - Celsius Degrees


JUMPER 3 = Circulation Pump:
                                                         Position 1             Position 2
Position 1 - System without a Circ. Pump

Position 2 - System with a Circ. Pump


http://www.MyPoolSpas.com                 Wholesale Pool and Spa Parts         920-925-3094
ECO-3 SERIES - BASIC OPERATION
                                                                                   PUMP 1 KEY
                                           COMPONENT “ON”                          PUMP 2 KEY
                                               INDICATORS                          AIR BLOWER KEY
                                                                                   LIGHT




                                                  104

                                                                          UP & DOWN ARROW KEYS


            Pump 1 Key: Press this key once to turn Pump 1 on. A second press will turn it off. For dual speed
            pump operation; Press this key once to turn Pump 1 onto Low speed, press this key a second time
            to turn Pump 1 onto High speed, a third press will turn the pump off. A built-in timer will shut the
            pump off after 20 minutes of operation unless done so manually. The Pump 1 Icon will appear on
            the LCD while the pump is running in High speed and flash while it is in Low speed. If the filter icon
            appears, a filtration cycle has begun and you will not be able to turn the pump off.


            Pump 2 Key: Press this key once to turn Pump 2 on. A second press will turn it off. A built-in timer will
            shut the pump off after 20 minutes of operation unless done so manually. The Pump 2 Icon will appear
            while the pump is running in High speed.



            Air Blower Key: Press this key once to turn Air Blower on. A second press will turn the Air Blower off. A
            built-in timer will shut the blower off after 20 minutes of operation unless done so manually. The Air
            Blower Icon will appear while the blower is running.



            Light Key: Press this key to turn the light on. A second press will turn the Light off. If equipped with Fiber
            Optic: Press this key once to show “L1”. Use the Up arrow key to turn the light on and off. Press the light
            key a second time, “F1” will appear. Use the Up arrow key to turn the Fiber Optic wheel and light on,
            Fiber Optic wheel off with light on and both Off. The light will automatically shut off after 2 hours. The
            Light Icon will appear while the light is on.




            Temperature Set Keys: Press the Up Arrow key to increase the desired temperature. Press the Down
            Arrow key to decrease the temperature. The temperature can be adjusted in 1BF increments from 59BF
            to 104BF (5BC to 40BC). The new setting will remain on the display for 5 seconds as a confirmation.
            During this time the Set Point icon will be appear to let you know this is the desired and not the actual
            temperature. After 5 seconds the display will return to the current temperature reading. When the
            temperature drops to 1BF below the set temperature, the heater will be turned on until the temperature is
            1BF above the set temperature. The heater icon will appear while the heater is on and flash when there is
            a call for heat and the heater has not yet been activated.


            Power Loss: Any interruption of power will cause the unit to reset and revert to the default
            programming of 95BF set point temperature and 2, 2-hour filtration cycles.



http://www.MyPoolSpas.com                    Wholesale Pool and Spa Parts                                   920-925-3094
ECO-3 SERIES - ERROR MESSAGES
                            Three Flashing Dots with Pump Off: To prevent damage to your equipment,
                            Hydro-Quip installs a pressure or flow switch. If 3 flashing dots appear below the
                            temperature display while there is no pump(s) operating, turn the pump(s) on. If the
        .104
          ..                3 flashing dots went away this indicates that the pressure or flow switch was
                            activated although there was no water flow.
                            Contact your local dealer




                            Three Flashing Dots with Pump On: If 3 flashing dots appear below the
                            temperature display while the pump(s) is operating, turn the pump(s) off. If the 3
                            flashing dots went away this indicates that the pressure or flow switch was not
                            activated although there was water flow. Note: A dirty filter limiting the water flow
        .104
          ..                will also cause this error message to appear.

                            When the pump is turned on, there is a 7-second delay before the system will start to
                            auto check the pressure or flow switch.

                            Contact your local dealer




        . .32
            .

                            Temperature Sensor: If the display shows a constant 32BF or 125BF and this is not the
            OR
                            actual temperature or the displayed temperature greatly differs from the actual spa
                            water temperature, a problem with the water temperature sensor has occurred.
                            Contact your local dealer



        .125
          ..




                            High Temperature: If the water temperature exceeds 119BF, the Hi-Limit protection
                            will be turned on and the heater will be deactivated until the water has cooled to 110BF.
                            3 flashing dots will appear below the elevated temperature. Power to the system must
        .120
          ..                be cycled off then on to reset the system.
                            Contact your local dealer

                            Freeze Protection & Winterizing: When freezing weather and/or power losses are
                            expected, contact your local spa dealer for freeze protection or winterizing
                            recommendations for both the spa and the equipment system. Freeze related
                            damage is not covered by the Hydro-Quip warranty.




85-0062-J                                        REV.0                                                      07/03
http://www.MyPoolSpas.com           Wholesale Pool and Spa Parts                                    920-925-3094

More Related Content

What's hot

Kjr 29 b (termostato alam. fan coil)
Kjr 29 b (termostato alam. fan coil)Kjr 29 b (termostato alam. fan coil)
Kjr 29 b (termostato alam. fan coil)German Nava
 
Micro dimmer module qubino manual
Micro dimmer module qubino manualMicro dimmer module qubino manual
Micro dimmer module qubino manualDomotica daVinci
 
Manual of Thermostat Fan Coil 4Pipes MH8 series - MCO HOME
Manual of Thermostat Fan Coil 4Pipes MH8 series - MCO HOME Manual of Thermostat Fan Coil 4Pipes MH8 series - MCO HOME
Manual of Thermostat Fan Coil 4Pipes MH8 series - MCO HOME Domotica daVinci
 
Siemens room stat instructions
Siemens room stat instructionsSiemens room stat instructions
Siemens room stat instructionsMaria Isabel
 
Qubino flush heat__cool_thermostat_user-manual_v1.2_eng
Qubino flush heat__cool_thermostat_user-manual_v1.2_engQubino flush heat__cool_thermostat_user-manual_v1.2_eng
Qubino flush heat__cool_thermostat_user-manual_v1.2_engDomotica daVinci
 
Qubino flush dimmer Z-Wave Plus ZMNHDD1 Manual
Qubino flush dimmer Z-Wave Plus ZMNHDD1 ManualQubino flush dimmer Z-Wave Plus ZMNHDD1 Manual
Qubino flush dimmer Z-Wave Plus ZMNHDD1 ManualDomotica daVinci
 
Anole Hot Runner Controller
Anole Hot Runner ControllerAnole Hot Runner Controller
Anole Hot Runner ControllerAnole Hot Runner
 

What's hot (17)

In k200 for xe quick reference card
In k200 for xe quick reference cardIn k200 for xe quick reference card
In k200 for xe quick reference card
 
Kjr 29 b (termostato alam. fan coil)
Kjr 29 b (termostato alam. fan coil)Kjr 29 b (termostato alam. fan coil)
Kjr 29 b (termostato alam. fan coil)
 
Mh8 fc um
Mh8 fc umMh8 fc um
Mh8 fc um
 
SP118 Manual+Ultisolar New Energy Co Ltd Solar Pump Station Solar Water Heate...
SP118 Manual+Ultisolar New Energy Co Ltd Solar Pump Station Solar Water Heate...SP118 Manual+Ultisolar New Energy Co Ltd Solar Pump Station Solar Water Heate...
SP118 Manual+Ultisolar New Energy Co Ltd Solar Pump Station Solar Water Heate...
 
SP118 Solar Working Station 2014 New Manual
SP118 Solar Working Station 2014 New ManualSP118 Solar Working Station 2014 New Manual
SP118 Solar Working Station 2014 New Manual
 
SP226 Manual+Ultisolar New Energy Co Ltd Solar Pump Station Solar Water Heate...
SP226 Manual+Ultisolar New Energy Co Ltd Solar Pump Station Solar Water Heate...SP226 Manual+Ultisolar New Energy Co Ltd Solar Pump Station Solar Water Heate...
SP226 Manual+Ultisolar New Energy Co Ltd Solar Pump Station Solar Water Heate...
 
SP116 Manual+Ultisolar New Energy Co Ltd Solar Pump Station Solar Water Heate...
SP116 Manual+Ultisolar New Energy Co Ltd Solar Pump Station Solar Water Heate...SP116 Manual+Ultisolar New Energy Co Ltd Solar Pump Station Solar Water Heate...
SP116 Manual+Ultisolar New Energy Co Ltd Solar Pump Station Solar Water Heate...
 
Micro dimmer module qubino manual
Micro dimmer module qubino manualMicro dimmer module qubino manual
Micro dimmer module qubino manual
 
Manual of Thermostat Fan Coil 4Pipes MH8 series - MCO HOME
Manual of Thermostat Fan Coil 4Pipes MH8 series - MCO HOME Manual of Thermostat Fan Coil 4Pipes MH8 series - MCO HOME
Manual of Thermostat Fan Coil 4Pipes MH8 series - MCO HOME
 
Siemens room stat instructions
Siemens room stat instructionsSiemens room stat instructions
Siemens room stat instructions
 
85 0066-d rev 1 hq ultimate dealer guide
85 0066-d rev 1 hq ultimate dealer guide85 0066-d rev 1 hq ultimate dealer guide
85 0066-d rev 1 hq ultimate dealer guide
 
Manual epack
Manual epackManual epack
Manual epack
 
Qubino flush heat__cool_thermostat_user-manual_v1.2_eng
Qubino flush heat__cool_thermostat_user-manual_v1.2_engQubino flush heat__cool_thermostat_user-manual_v1.2_eng
Qubino flush heat__cool_thermostat_user-manual_v1.2_eng
 
Manual acc
Manual accManual acc
Manual acc
 
Qubino flush dimmer Z-Wave Plus ZMNHDD1 Manual
Qubino flush dimmer Z-Wave Plus ZMNHDD1 ManualQubino flush dimmer Z-Wave Plus ZMNHDD1 Manual
Qubino flush dimmer Z-Wave Plus ZMNHDD1 Manual
 
2
22
2
 
Anole Hot Runner Controller
Anole Hot Runner ControllerAnole Hot Runner Controller
Anole Hot Runner Controller
 

Viewers also liked (16)

55646 vsp vs300_fc5_ccah
55646 vsp vs300_fc5_ccah55646 vsp vs300_fc5_ccah
55646 vsp vs300_fc5_ccah
 
54370 03 vsp_vs500_z_ccaj
54370 03 vsp_vs500_z_ccaj54370 03 vsp_vs500_z_ccaj
54370 03 vsp_vs500_z_ccaj
 
Hotwater products
Hotwater productsHotwater products
Hotwater products
 
53641 0320 gs5_gs510s_rca-30k
53641 0320 gs5_gs510s_rca-30k53641 0320 gs5_gs510s_rca-30k
53641 0320 gs5_gs510s_rca-30k
 
54639 01 vsp_vs514_sz_ycah
54639 01 vsp_vs514_sz_ycah54639 01 vsp_vs514_sz_ycah
54639 01 vsp_vs514_sz_ycah
 
40192 a
40192 a40192 a
40192 a
 
85 0076-c 6220 troubleshooting
85 0076-c 6220 troubleshooting85 0076-c 6220 troubleshooting
85 0076-c 6220 troubleshooting
 
85 0135 a-rev 1_installation manual
85 0135 a-rev 1_installation manual85 0135 a-rev 1_installation manual
85 0135 a-rev 1_installation manual
 
50hz eng non_m7
50hz eng non_m750hz eng non_m7
50hz eng non_m7
 
85 0100 b universal air installation
85 0100 b universal air installation85 0100 b universal air installation
85 0100 b universal air installation
 
54386 04 e1_p_el1000m3_dcah
54386 04 e1_p_el1000m3_dcah54386 04 e1_p_el1000m3_dcah
54386 04 e1_p_el1000m3_dcah
 
60hz eng non_m7
60hz eng non_m760hz eng non_m7
60hz eng non_m7
 
55067 03 e2_p_el2001m3_ycah
55067 03 e2_p_el2001m3_ycah55067 03 e2_p_el2001m3_ycah
55067 03 e2_p_el2001m3_ycah
 
54763 01 gs5_gs523_dz_rca-30
54763 01 gs5_gs523_dz_rca-3054763 01 gs5_gs523_dz_rca-30
54763 01 gs5_gs523_dz_rca-30
 
Sspa 1 and sspa-mp spa packs
Sspa 1 and sspa-mp spa packsSspa 1 and sspa-mp spa packs
Sspa 1 and sspa-mp spa packs
 
Vs 300 fl4 manual
Vs 300 fl4 manualVs 300 fl4 manual
Vs 300 fl4 manual
 

Similar to ECO-3 SERIES POWER WIRING

Dom icondens he-26c-manual
Dom icondens he-26c-manualDom icondens he-26c-manual
Dom icondens he-26c-manualLewisHunt
 
Aeotec Multisensor 7 Manual
Aeotec Multisensor 7 ManualAeotec Multisensor 7 Manual
Aeotec Multisensor 7 ManualDomotica daVinci
 
Boiler flame scanner retrofitting
Boiler flame scanner retrofittingBoiler flame scanner retrofitting
Boiler flame scanner retrofittingAnimesh Dan
 
Solar Work Station SP118
Solar Work Station SP118Solar Work Station SP118
Solar Work Station SP118Jussi Han
 
Variomat2 training
Variomat2 trainingVariomat2 training
Variomat2 trainingCalpeda
 

Similar to ECO-3 SERIES POWER WIRING (20)

Standard spaside instruction sheet
Standard spaside instruction sheetStandard spaside instruction sheet
Standard spaside instruction sheet
 
Cti troublshooting
Cti troublshootingCti troublshooting
Cti troublshooting
 
Eco 2 spaside instruction sheet
Eco 2 spaside instruction sheetEco 2 spaside instruction sheet
Eco 2 spaside instruction sheet
 
Sc cf-sbd quick reference card
Sc cf-sbd quick reference cardSc cf-sbd quick reference card
Sc cf-sbd quick reference card
 
Eco 1 spaside instruction sheet
Eco 1 spaside instruction sheetEco 1 spaside instruction sheet
Eco 1 spaside instruction sheet
 
Manual epack
Manual epackManual epack
Manual epack
 
Dom icondens he-26c-manual
Dom icondens he-26c-manualDom icondens he-26c-manual
Dom icondens he-26c-manual
 
Uc cf single-pump system quick reference card
Uc cf single-pump system quick reference cardUc cf single-pump system quick reference card
Uc cf single-pump system quick reference card
 
85 0066-c rev 1 hq ultimate troubleshooting manual
85 0066-c rev 1 hq ultimate troubleshooting manual85 0066-c rev 1 hq ultimate troubleshooting manual
85 0066-c rev 1 hq ultimate troubleshooting manual
 
85 0066-c hq ultimate troubleshooting manual
85 0066-c hq ultimate troubleshooting manual 85 0066-c hq ultimate troubleshooting manual
85 0066-c hq ultimate troubleshooting manual
 
85 0066-c rev 1 hq ultimate troubleshooting manual
85 0066-c rev 1 hq ultimate troubleshooting manual85 0066-c rev 1 hq ultimate troubleshooting manual
85 0066-c rev 1 hq ultimate troubleshooting manual
 
Aeotec Multisensor 7 Manual
Aeotec Multisensor 7 ManualAeotec Multisensor 7 Manual
Aeotec Multisensor 7 Manual
 
Manual acc
Manual accManual acc
Manual acc
 
85 0100 a-rev 1_univ air operation_web
85 0100 a-rev 1_univ air operation_web85 0100 a-rev 1_univ air operation_web
85 0100 a-rev 1_univ air operation_web
 
Boiler flame scanner retrofitting
Boiler flame scanner retrofittingBoiler flame scanner retrofitting
Boiler flame scanner retrofitting
 
SP228 Ultisolar Solar Working Station Manual
SP228 Ultisolar Solar Working Station ManualSP228 Ultisolar Solar Working Station Manual
SP228 Ultisolar Solar Working Station Manual
 
SP228 Manual+Ultisolar New Energy Co Ltd Solar Pump Station Solar Water Heate...
SP228 Manual+Ultisolar New Energy Co Ltd Solar Pump Station Solar Water Heate...SP228 Manual+Ultisolar New Energy Co Ltd Solar Pump Station Solar Water Heate...
SP228 Manual+Ultisolar New Energy Co Ltd Solar Pump Station Solar Water Heate...
 
Solar Work Station SP118
Solar Work Station SP118Solar Work Station SP118
Solar Work Station SP118
 
Variomat2 training
Variomat2 trainingVariomat2 training
Variomat2 training
 
Bl 40 troubleshooting guide
Bl 40 troubleshooting guideBl 40 troubleshooting guide
Bl 40 troubleshooting guide
 

More from Accurate Pool & Spa Services, llc

More from Accurate Pool & Spa Services, llc (20)

Ultimate spaside instruction sheet
Ultimate spaside instruction sheetUltimate spaside instruction sheet
Ultimate spaside instruction sheet
 
Ps 9704 manual-rev1_2
Ps 9704 manual-rev1_2Ps 9704 manual-rev1_2
Ps 9704 manual-rev1_2
 
Ps 7100 manual-rev1_2
Ps 7100 manual-rev1_2Ps 7100 manual-rev1_2
Ps 7100 manual-rev1_2
 
Ps 6500 manual-rev1_2
Ps 6500 manual-rev1_2Ps 6500 manual-rev1_2
Ps 6500 manual-rev1_2
 
Hq label wd highlight
Hq label wd highlightHq label wd highlight
Hq label wd highlight
 
Eco 2 pcb revisions
Eco 2 pcb revisionsEco 2 pcb revisions
Eco 2 pcb revisions
 
Eco 1 programming
Eco 1 programmingEco 1 programming
Eco 1 programming
 
Deluxe spaside instruction sheet
Deluxe spaside instruction sheetDeluxe spaside instruction sheet
Deluxe spaside instruction sheet
 
Cs9700 software upgrade notice 3 07
Cs9700 software upgrade notice 3 07Cs9700 software upgrade notice 3 07
Cs9700 software upgrade notice 3 07
 
Cs9700 llp settings 3 07
Cs9700 llp settings 3 07Cs9700 llp settings 3 07
Cs9700 llp settings 3 07
 
Control cord colors
Control cord colorsControl cord colors
Control cord colors
 
850077 a outdoor operation
850077 a outdoor operation850077 a outdoor operation
850077 a outdoor operation
 
9400 9600 programming
9400 9600 programming9400 9600 programming
9400 9600 programming
 
9300 programming
9300 programming9300 programming
9300 programming
 
85 0138 infrared remote-web
85 0138 infrared remote-web85 0138 infrared remote-web
85 0138 infrared remote-web
 
85 0137 rev 1-palm pilot programming_web
85 0137 rev 1-palm pilot programming_web85 0137 rev 1-palm pilot programming_web
85 0137 rev 1-palm pilot programming_web
 
85 0136 spaside cutout template
85 0136 spaside cutout template85 0136 spaside cutout template
85 0136 spaside cutout template
 
85 0135 b-installation manual_web
85 0135 b-installation manual_web85 0135 b-installation manual_web
85 0135 b-installation manual_web
 
85 0079 vds insert
85 0079 vds insert85 0079 vds insert
85 0079 vds insert
 
85 0076-e eco-2 plus-installation insert_web
85 0076-e eco-2 plus-installation insert_web85 0076-e eco-2 plus-installation insert_web
85 0076-e eco-2 plus-installation insert_web
 

ECO-3 SERIES POWER WIRING

  • 1. ECO-3 SERIES - INCOMING POWER WIRING All Universal systems leave configured 120-Volt input power (Option 1). OPTION 1 OPTION 2 L1 to L2 Jumper IMPORTANT - 3-Wire 240V Systems, DO NOT Connect Neutral Wire L1 N GR L1 N GR L2 120-Volt electrical service requires: 240-Volt electrical service requires: Line 1, Neutral and Ground. Line 1, Lin 2, Neutral and Ground. (Line 1 to Line 2 jumper must be in place (Line 1 to Line 2 jumper must be removed) for system to operate properly) IMPORTANT: Always refer to the product data label (located on top of control box) for specific electrical information. http://www.MyPoolSpas.com Wholesale Pool and Spa Parts 920-925-3094
  • 2. ECO-3 LOW LEVEL PROGRAMMING It is possible to change the parameters of the system by positioning specific jumpers located on the system board (see illustration below). JUMPER #1 - CURRENT LIMITING JUMPER #2 - TEMPERATURE DISPLAY JUMPER #3 - CIRCULATION PUMP JUMPER 1 = Current Limiting: Position 1 - (High Current 240vac): There is no current restriction. This allows the heater to operate with the pump in high speed. Position 2 - (Low Current 120vac): The system will not turn the heater on when the pump is in high speed. The heater indicator will flash on the spaside to tell the user that there is a call for heat but the heater is not allowed to start. JUMPER 2 = Temperature Display: Position 1 - Fahrenheit Degrees Position 2 - Celsius Degrees JUMPER 3 = Circulation Pump: Position 1 Position 2 Position 1 - System without a Circ. Pump Position 2 - System with a Circ. Pump http://www.MyPoolSpas.com Wholesale Pool and Spa Parts 920-925-3094
  • 3. ECO-3 SERIES - BASIC OPERATION PUMP 1 KEY COMPONENT “ON” PUMP 2 KEY INDICATORS AIR BLOWER KEY LIGHT 104 UP & DOWN ARROW KEYS Pump 1 Key: Press this key once to turn Pump 1 on. A second press will turn it off. For dual speed pump operation; Press this key once to turn Pump 1 onto Low speed, press this key a second time to turn Pump 1 onto High speed, a third press will turn the pump off. A built-in timer will shut the pump off after 20 minutes of operation unless done so manually. The Pump 1 Icon will appear on the LCD while the pump is running in High speed and flash while it is in Low speed. If the filter icon appears, a filtration cycle has begun and you will not be able to turn the pump off. Pump 2 Key: Press this key once to turn Pump 2 on. A second press will turn it off. A built-in timer will shut the pump off after 20 minutes of operation unless done so manually. The Pump 2 Icon will appear while the pump is running in High speed. Air Blower Key: Press this key once to turn Air Blower on. A second press will turn the Air Blower off. A built-in timer will shut the blower off after 20 minutes of operation unless done so manually. The Air Blower Icon will appear while the blower is running. Light Key: Press this key to turn the light on. A second press will turn the Light off. If equipped with Fiber Optic: Press this key once to show “L1”. Use the Up arrow key to turn the light on and off. Press the light key a second time, “F1” will appear. Use the Up arrow key to turn the Fiber Optic wheel and light on, Fiber Optic wheel off with light on and both Off. The light will automatically shut off after 2 hours. The Light Icon will appear while the light is on. Temperature Set Keys: Press the Up Arrow key to increase the desired temperature. Press the Down Arrow key to decrease the temperature. The temperature can be adjusted in 1BF increments from 59BF to 104BF (5BC to 40BC). The new setting will remain on the display for 5 seconds as a confirmation. During this time the Set Point icon will be appear to let you know this is the desired and not the actual temperature. After 5 seconds the display will return to the current temperature reading. When the temperature drops to 1BF below the set temperature, the heater will be turned on until the temperature is 1BF above the set temperature. The heater icon will appear while the heater is on and flash when there is a call for heat and the heater has not yet been activated. Power Loss: Any interruption of power will cause the unit to reset and revert to the default programming of 95BF set point temperature and 2, 2-hour filtration cycles. http://www.MyPoolSpas.com Wholesale Pool and Spa Parts 920-925-3094
  • 4. ECO-3 SERIES - ERROR MESSAGES Three Flashing Dots with Pump Off: To prevent damage to your equipment, Hydro-Quip installs a pressure or flow switch. If 3 flashing dots appear below the temperature display while there is no pump(s) operating, turn the pump(s) on. If the .104 .. 3 flashing dots went away this indicates that the pressure or flow switch was activated although there was no water flow. Contact your local dealer Three Flashing Dots with Pump On: If 3 flashing dots appear below the temperature display while the pump(s) is operating, turn the pump(s) off. If the 3 flashing dots went away this indicates that the pressure or flow switch was not activated although there was water flow. Note: A dirty filter limiting the water flow .104 .. will also cause this error message to appear. When the pump is turned on, there is a 7-second delay before the system will start to auto check the pressure or flow switch. Contact your local dealer . .32 . Temperature Sensor: If the display shows a constant 32BF or 125BF and this is not the OR actual temperature or the displayed temperature greatly differs from the actual spa water temperature, a problem with the water temperature sensor has occurred. Contact your local dealer .125 .. High Temperature: If the water temperature exceeds 119BF, the Hi-Limit protection will be turned on and the heater will be deactivated until the water has cooled to 110BF. 3 flashing dots will appear below the elevated temperature. Power to the system must .120 .. be cycled off then on to reset the system. Contact your local dealer Freeze Protection & Winterizing: When freezing weather and/or power losses are expected, contact your local spa dealer for freeze protection or winterizing recommendations for both the spa and the equipment system. Freeze related damage is not covered by the Hydro-Quip warranty. 85-0062-J REV.0 07/03 http://www.MyPoolSpas.com Wholesale Pool and Spa Parts 920-925-3094