Bluetooth Based Fire Detection and Robust Protection System By Using Arduino
SL ENGINEERS COMPANY PROFILE__
1. ENGINEERS
PROFILE
SL ENGINEERS
A COMPLETE SOLUTION OF FIRE FIGHTING SYSTEMS
_________________________________________
Head Office: SCO-79, 2nd
Floor, Sector - 10A,
Khandsa Road, Gurgaon (HARYANA)
Telefax: - 0124-4140582
Mob: - 9999335471, 9582222683, 9999839387
Website:- www.slengineers.co.in
E-mail: - slengineersgurgaon@gmail.com,
fire_engineers@rediffmail.com
marketing.slengineers@gmail.com
Sale Tax No:- 06921933823
Branch Office: Shop no-FF-05,First Floor,Konark Oasis Shopping
Complex
Alwar Bypass Road,Bhiwadi
Rajasthan-301019
Mob: - 9999335471, 9999839387,9711618431
E-mail : fire_engineers@rediffmail.com,
slengineersbhiwadi@gmail.com
Sale Tax No:- 08754203732
2. S L ENGINEERS
Page 2
27/04/2016
M/S: - Jaycee Castalloys Pvt. Ltd.
Plot No-9, Sector-4B
IMT, Bahadurgarh, Haryana
Kind Atten:- Mr. S.K.Agarwal
SUBJECT: - Supply, Installation, Testing & Commissioning of Automatic Fire Fighting,
Sprinkler, Convention & Addressable, Intelligent Detection, Manual Alarm & Fire
Extinguishers System.
Dear Sir,
We, SL Engineers take this opportunity to introduce ourselves as a leading
Fire Safety and Building System Integration Organization for the subject System. We
have enjoyed the privilege of serving major Govt. & Public Sector. Undertaking,
leading Private Sector Organization, Corporate, Consultants and Care Sector
Industries as Fire Hydrant, Fire Fighting, Gas Flooding, Security System, Public
Address System and Building Integration as Turnkey Solution provider on a number of
Project since last 12 years.
Total quality management concepts imbibing on-time delivery and impeccable quality of
products are our focused areas of concentration. Your encouragement will from the
Foundation of our long term partnership with your august organization.
With the proven past track records and our impressive clientele list. We strongly feel
that we can offer you absolute start-of-the-art products at competitive pricing to cater to
your requirements.
3. S L ENGINEERS
Page 3
We request you to kindly include SL Engineers. In your list of approved vendors for the
above referred specialized segments and consider us for your forthcoming requirements.
As instructed by you, please find enclosed the below mentioned details of over for your
kind reference / record and consideration.
Hope that the above information will meet your requirement and satisfy your queries
concerns and help in establishing our strong credential. However if you require any
further details, please revert back. A line in confirmation to this effect will be highly
appreciated.
Kindly allocate a suitable time slot of approximately 30 minutes for an opportunity to
introduce our-self in person.
Thanking you assuring you of our best attention services.
Yours Faithfully
FOR
SL ENGINEERS
A Complete Solution of Fire Fighting Systems
SACHIN SOLANKI / PRADEEP RAJPUT
(+91- 9999335471/ 9582222683)
4. S L ENGINEERS
Page 4
Index
S.No. Pattern Heading Page No.
1. The Systems We offer 5 – 12
(Fire Hydrant Systems, Water Based Systems,
Gas Based Systems, Automatic Sprinkler Systems,
Fire Alarm system)
2. Introduction 13
3. Safety Procedure 14
4. List Of Tools And Tackles 15
5. Management Team 16
6. List Of Key Person 17 – 19
7. Our Architects & Consultants 20 – 21
8. Client List 22 – 32
SL ENGINEERS
A Complete Solution ofFire Fighting Systems
5. S L ENGINEERS
Page 5
The System we offer: -
1. Fire Hydrant System.
2. Automatic Sprinkler System.
3. Conventional, Intelligent and Manual Fire Alarm System.
4. Smoke Detector System.
5. Smart Home Automation & Security System.
6. Electronic Security System with Access Control, Time Attendance System
Intruder Alarm System.
7. All type of ISI Marks Fire Extinguisher System
We can provide solution to fit all the circumstances and budgets. SL Engineers is
equipped with independent Technical System Division to meet Client requirement from
the design to the completion stage. We have in House Design capability of all fire and
security project in accordance with the spectrum of products and market sectors.
6. S L ENGINEERS
Page 6
1. FIRE HYDRANT SYSTEM
1. Water Based
Fireproof offers a range of Water Based Protection System like: - Sprinkler, Hydrant,
Protection system, kitchen hood system, high and medium velocity mist system and tank
foam system to suit individual fire protection needs.
2. Gas Based
In addition of fire detection and alarm system organization that have a dedicated server
/ rack room should have minimum gas suppression system. The different types of gas
suppression system available are CO2, NAF, FM 200 and interring.
7. S L ENGINEERS
Page 7
WATER BASED
HYDRANT SYSTEM
A well designed and a well laid out Hydrant system forms the backbone of the entire
firefighting system.
Hydrant Fire Protection System is designed to fight fire of huge proportions, in all
classes of risk. It is designed to be in operation even if a part of the affected structure
collapses. This system consists of yard hydrant piping systems, internal hydrant piping,
hose reel drums, hose cabinets, internal and external hydrant valves and set of pumps.
Target Industry segment Commercial Buildings, Industries, Power Planets, Refineries,
Residential Apartment, Theatres, and Telephone Exchanges.
System Description:
The Hydrant system typically comprises of the fire water sources, pumps (diesel,
electrical), control panel, system piping, control valve and hydrant valve with
accessories standards & compliance NBC, NFPA, IS FM and locates fire authorities.
Alliances & Partners:
All materials required for this system are available indigenously. Select clientele Texas
Instruments, Motorola ITPL, ING VYSYA, Influx, A Star IDL, BPL, and Lapp Kassel
Viacom.
8. S L ENGINEERS
Page 8
GAS BASED
FM 200 CO2 FLOODING SYSTEMS.
The FM 200 agent is one of most effective fire suppressants available for stopping fire
before they cause any damage. The FM 200 agent is safe for environment, people and
property and has an unblemished record of safety in use. Fire suppression systems
employing FM 200 agent are ideal for most fire protection applications that involve high
value assets and mission critical facilities. FM 200 gas storage cylinders consume less
space compared to other extinguishing agents like inter green. FM 200 system requires
10 seconds or less for release of gas, thus stopping ordinary combustible, electrical and
flammable liquid fires before they can cause any significant damage. Fire extinguished
quickly, means less damage, less repair coast, less downtime and disruption of business.
Target Industry segment software Facilities Telecom Centers Banks, Oil and Gas
Facilities System Description. The chemical content of the FM 200 agent is Heptads Flour
propane.
FM 200 system is operated by intelligent / conventional fire detection and alarm systems
designed especially for fire extinguish ant agents. During fire, heat is generated though
the release of chemical energy in order for combustion to self-propagate. FM 200
molecules rapidly absorb heat from within the chemical reaction so that the temperature
falls below the critical point and the fire is extinguished. The FM 200 gas is stored in re-
usable containers. Every container comes with a high rate discharge valve with integral
pressure gauge.
The intelligent /conventional detectors sense the fire and send signal to the
extinguishing panel which in turn initiates discharge of gas through the electrically
operated valve on top of the cylinder, Standards & Compliance NFPA, BIS
Alliances & Partners Great Lakes, Fakes
Select Clientele SYKES
9. S L ENGINEERS
Page 9
3. AUTOMATIC SPRINKLER SYSTEM.
Sprinkler system provides the best form of protection, as it is designed to both detect and
extinguish fire, the important aspect of this system is that it directly attacks the seat of
the fire avoiding unnecessary floor wettings. With this system in place chances of fire
spreading to other areas is also eliminated.
TargetIndustry Segment:
All kinds of Building, Parking areas etc. system description. The Sprinkler System
typically comprises of Fire Water Source, Diesel and Electrical Pumps Control Panel,
Sprinkler Bulb, System Piping, Control Valves and Annunciater Panel.
The sprinkler system is maintained under a stipulated pressure and the sprinkler bulbs
are rated to fuse at a set temperature. In case of fire, the rise in temperature of the liquid
inside the bulb cause it to fuse and release a fine jet of water over the seat thus
extinguishing it the bursting of the bulbs and water spraying action causes the line
pressure to drop, which in turn triggers the fire pumps into operation, thereby,
supplying the required quantity of water into the system. The coverage area of the
sprinkler bulb is designed as per the hazard category of the specified in NFPA and
regulation provided by Indian National Building Coed of India
Standards & Compliance NBC, NFPA, FM, TAC and Local Fire Authorities, Alliances &
Partners. All materials required for this system are available indigenously.
Select Clientele Texas instruments, Motorola, Intel, ITPL, ING, VYSYA, Prestige Group,
Embassy Group.
10. S L ENGINEERS
Page 10
3. FIRE ALARM SYSTEM
ConventionalSystem
Conventional Fire Alarm System provides the earliest practicable fire detection and
warning this System consist of smoke or heat detectors at designated locations. To detect
smoke or heat at the earliest during any outbreak of fire.
IntelligentAddressable System
Intelligent Addressable System offer benefits in terms of speed and detection,
identification of the location of fire and easier maintenance. Intelligent systems also offer
tolerance to faults in the system wiring which allows a Single pair of wires to be used to
connect up to 200 devices to the system, allowing cost saving in the wiring of large
systems.
Security Alarm System
Here we are providing round the clock security for any kind premises. Without being
worried about human being mistakes, premises will be protected with the help of
sensors, siren control panel, auto dialer etc. in case of any signal dialer will give you the
message of incident, and additionally CMS facility will provide you extra back and
response of incident.
11. S L ENGINEERS
Page 11
4. SMOKE DETECTOR SYSTEM
Orbits operate on the well-established light scatter principle. The remarkable optical
design of the Orbits optical smoke detector allows it to respond to abide spectrum of
fires. The sensing chamber of the orbits optical smoke detector contains an optical sensor
which measures back-scattered light as well as the move usual forward scattered light.
Sensitivity to back smoke is greatly improved. The detector is calibrated so that orbits is
highly reliable in detecting fires but is much less likely to generate false alarms then
ionization smoke detectors.
The stability of the detector high reliability, low false alarm rate is further increased by
the use of algorithms to decide when the detector should change to the alarm state. This
removes the likelihood of a detector producing an alarm as a result of smoke from
smoking materials or from another non-fire source.
The sensing chamber has been designed to keep out dust and other airborne
contaminants.
We offer the broadestline conventionalsmoke detection.
Our new i3 series takes a unique approach toward reducing costs with its installation
ease, intelligence and instant inspection. And our carbon monoxide, heat and beam
detectors provide an effective solution when specialty detection is required.
System sensor’s intelligent smoke detectors use advanced communication protocols to
ensure accuracy and stability. Sophisticated software provides false reduction and
automatically monitors detectors sensitivity. Extensive research and development allow
us to optimize technologies based on environment and risk.
Take a look at laser technology used in clean rooms and communication centers, difficult
environment smoke detectors for dusty or dirty facilities, multi-criteria for areas
requiring stability and performance and intrinsically safe smoke detectors for hazardous
environment.
12. S L ENGINEERS
Page 12
Features:
MICROPROCESSOR BASED DOLPHIN SERIES PANEL.
16 x 2 line character LCD Display for user interface.
Individual LED indication for zone status.
Keyboard lock facility
Individual Zone Enable / Disable function.
High Accuracy
Network panel – one master panel.
Modular Design.
Optional Features
CO2 Gas Release module with part-set time
Auto Dialer which can automatically dial up to 4 pre-programmed numbers at any event.
Unlimited Number of Slave panels.
Technical Specifications
Model: Dolphin panel
Power: AC230 V / 24V D.C.
Housing: M.S. Sheet
Color: Grey Front & Off White Back
Weight: 6 Kg.
E.O.L.: 4K70hm
No. of Zones: As per order
Dimension: 12’ x 12’ x 3.5’ (only up to 4 zones)
Low Battery
Fire
Fault
Main
13. S L ENGINEERS
Page 13
INTRODUCTION
We are pleased to take this opportunity to introduce ourselves as concern of M/s.
SL Engineers fire protection system (The Fire Fighting Service Provider in Pan India).
We have very sophisticated & modernized set up in heart of millennium city Gurgaon.
We have been achieving group turnover to the tune of 28.35.49 crore ( Twenty Eight
Crore Thirty Five Lacs And Forty Nine Thousands). with efforts of our dedicated
technical team of Engineers and quality vision & supports of our seniors.
Now SL Engineers has established their roots as a leading organization for providing
Turnkey based solutions for various segment engaged in execution of various fire
protection system / Hi Tech Electronic Security System from design state to the
commissioning stage. We provide tailor-made system on turnkey basis viz. (Design
Engineering, Supply Installation Testing & Commissioning)
We have successfully completed as Turnkey project to one of prestigious corporate
client organizations for commercial complex, Industrial & Multistoried – Residential
Societies etc.
SL Engineers registered office is located at Gurgaon (Haryana). It was launched
specifically to meet the up market demand for professions and very high quality
integrated firefighting services.
Our clients who have trusted “SL Engineers” to provide Security Management and
protection of their valuable assets, includes mainly MNC’s, Banks, International Malls,
Arcade, Shopping Plaza, City Centre,0 Shopping Malls, Super Specialty Hospitals, Govt.
Recognized Export, Houses, Manufacturing Plants, Educational Institutions, Residential
Townships, Cineplex, Public Schools, Organizations and Retail Outlets of repute.
The details for the above projects are being enclosed herewith. We have been getting
repeat orders from our clients based on the performance exhibited by us in their
previous jobs.
SL ENGINEERS
A Complete Solution ofFire Fighting System
14. S L ENGINEERS
Page 14
SAFETY PROCEDURES
Safety Site:-
All employees use safety helmets while working on site.
Welding is done only after ensuring that no inflammable material is lying nearby
and fire extinguishers are available.
Material is lifted with the help of proper chain pulley blocks and proper chain
thickness is also checked for lifting the weight.
During welding proper sunglass is used for the safety of eyes and gloves are used
for hands.
For avoiding major miss-happening piping is segmented in to different sections
and each section is tested hydraulically separately.
For underground piping welding joints are inspected through D.P. tests and
wherever required X-ray testing of joints is also done.
15. S L ENGINEERS
Page 15
LIST OF TOOLS AND TACKLES
S. No. ITEM DESCRIPTION QTY.
1. Restrict Fire Welding Machine 35 Nos.
2. Hydro Test Pump 35 Kg/Cm. 22 Nos.
3. Power Hacksaw Suitable up to 21” Pipe with 3 Phase 5HP
Motor
27 Nos.
4. Hand Grinder 37 Nos.
5. Electric Welding Set 450 Amps. Measuring Instruments, Venire
Calipers, Screw Gauge, Sprit Level (Tapes Etc.)
24 Nos.
6. Pipe Wipes 65 Nos.
7. Drilling Machine 58 Nos.
8. Gas Cutter 30 Nos.
9. Electric Threading Machine (Size 15 mm Dia to 100 mm Dia) 21 Nos.
10. Diesel Generator of 40 K.V.A. 06 Nos.
16. S L ENGINEERS
Page 16
MANAGEMENT TEAM
Mr. SACHIN SOLANKI(ManagingDirector)
Mr. SACHIN SOLANKI is a renowned property service expert with over 16 years of
experience in the field. He has worked in Key Senior positions both with corporate
occupiers and service providers. He has worked with several National FM Service
providers, typically at country and regional management level and has held positions on
the board of national service providers.
Mr. PRADEEPRAJPUT (Business Development Officer)
Mr. PRADEEP RAJPUT Builds market position by locating, developing, defining,
negotiating, and closing business relationships and an expert in the field of Fire Safety
which includes Fire Fighting and Fire Alarm Systems. Mr. Pradeep Rajput possess over
19 years of experience in Operations and Maintenance, Project Development and
Commissioning. He is a keen planner and strategist with demonstrated abilities in
managing project services for manufacturing Industries, Commercial Spaces, Hotel
Establishments, Hospitals, Malls etc. projects.
Mr. Y.S. TOMAR (ManagerofNoida Branch)
MR. Y.S. TOMAR is an expert in Designing and Implementation of CCTV SUR
VEILLANCE SYSTEMS including IP and Analogue Standalone and Web based Access
Control System and Home Automation Systems. Mr. Y. S. Tomar has over 9 years’
experience in Marketing and Implementation of the systems.
Some of major security systems projects are completed by Mr. Y.S. Tomar in his
previous organization: -
PUNJAB & SINDH BANK, DELHI PUBLIC SCHOOL, KAROL BAGH MARKET
AND CHANDNI CHOWK, SCOPE COMPLEX, MODLAMA EXPORT, V-MART
MALL – PITAMPURA NEW DELHI ETC.
17. S L ENGINEERS
Page 17
LIST OF KEY PERSON
BHARAT SINGH SOLANKI (C.E.O.)
(Head of the Team of System Division).
SACHIN SOLANKI (Managing Director)
(Responsible for Planning, Co-ordination & Management).
PRADEEP RAJPUT (Business Development Officer)
(Builds market position by locating, developing, defining, negotiating, and closing
business relationships ).
SANJEEV SOLANKI (DGM Services)
(Responsible for All Projects completion and Report to Head – Fire Division).
YASHPAL SINGH TOMAR (Manager of Noida Branch)
(Head of the team of system division, responsible for planning, designing, Co-
ordination, man power management & Reporting to Director).
CHETAN SINGH (Purchase Manager)
(Responsible for all type Material Fire Equipment & Plumbing etc).
SOMENDRA SINGH (Manager Of Bhiwadi Branch)
(Head of the team of system division, responsible for planning, designing, Co-
ordination, man power management & Reporting to Director).
NITIN GUPTA (Marketing - Executive)
(Responsible for Marketing & of all type of Fire Fighting and Fire Alarm System
for Societies, Industrial Buildings etc).
SAKET KUMAR (Marketing - Executive)
(Responsible for Marketing & of all type of Fire Fighting and Fire Alarm System
for Societies, Industrial Buildings etc).
18. S L ENGINEERS
Page 18
Miss VANDANA (Charted Accountant)
(Responsible for Final Accounts & all legally Work).
MOHIT KAUSHAL (Accounts Manager)
(Responsible for Accounts Work).
MUKESH KUMAR (Accountant of Noida Branch)
(Responsible for Accounts Work).
DHANESH KAUSHAL (Account Assistant)
(Responsible for Day to Day Accounts Reports)
PALASH SHARMA (Account Assistant)
(Responsible for Day to Day Accounts Reports)
SURYA TIWARI (Project Manager)
(Responsible for Day to Day Report to DGM Services).
VIKASH SINGH (Site Engineer)
(Responsible for Day to Day Report to Project Manager).
MD. RAJU (Site Engineer)
(Responsible for Day to Day Report to Project Manager).
GANESH SINGH (Site Supervisor)
(Responsible for Day to Day Report to Site Engineer).
SOHAN LAL (Site Supervisor)
(Responsible for Day to Day Report to Site Engineer).
RAM KUMAR (Site Supervisor)
(Responsible for Day to Day Report to Site Engineer).
19. S L ENGINEERS
Page 19
YOGESH SHARMA (Site Supervisor)
(Responsible for Day to Day Report to Site Engineer).
ANIL SHARMA (Site Supervisor)
(Responsible for Day to Day Report to Site Engineer).
RAJENDER PAL (Site Supervisor)
(Responsible for Day to Day Report to Site Engineer).
DEEPAK PANDEY (Site Supervisor)
(Responsible for Day to Day Report to Site Engineer).
MANISH UPADHYAY (Site Supervisor)
(Responsible for Day to Day Report to Site Engineer).
GAURAV YADAV (Site Supervisor)
(Responsible for Day to Day Report to Site Engineer).
20. S L ENGINEERS
Page 20
Our Architects & Consultants
Sachdeva Consultant (Gurgaon)
Vastunidhi Architects (Noida)
Mabas Architecture, Interiors, Planing (New Delhi)
Deepak Mehta & Associates, Delhi
B Sengupta And Architects, Bhiwadi
Nirman Consultants Pvt. Ltd. (New Delhi)
Aps-Green-Architects & Associate, Vaishali, Gaziabad
Arch10 Design Consultants,569,Sector-22b, Gurgaon
Space Designers International , Gaziabad
Interact Consultants Pvt. Ltd., Gurgaon
S.M. Engineers, Mumbai.
Saviram Engineering Con. Pvt. Ltd. (Noida)
M. J. Consultant (Mep) (New Delhi)
Consumate Engineering Services (P)Ltd. (Noida)
Bahera & Assiciates,Lado Sarai, (New Delhi)
Edge Studio Pvt. Ltd. C.P. (New Delhi)
Max Mep Consultants, Lajpat Nagar, (New Delhi)
Vinod Kumar Gupta, Pitampura , (New Delhi)
Semac Pvt. Ltd. (Arch., Eng., Planners) (New Delhi)
Incubis Consultants (India) Pvt. Ltd. (New Delhi)
Gian P. Mathur And Associates (P) Ltd. (New Delhi)
Daman Consultants, Sector-21a, Faridabad
Ras Consultants, Gurgaon
V.S Kukreja & Associates Pvt.Ltd., (New Delhi)
Mra Associates India Private Limited, New Manglapuri (New Delhi)
C To C Services Consultants Pvt. Ltd, Greenpark, (New Delhi)
N+U Architects & Consultants, Okhla, (New Delhi)
Ajit Shangari Consultants Pvt. Ltd. (New Delhi)
Rajiv Associates, Rajauri Garden, (New Delhi)
Kamal Raj Architects (New Delhi)
Engineering, Design & Consulting Org. (New Delhi)
Civil Consultants (Architects, Planner, Interior, Designers)
Andley & Associates, South Extension-I, (New Delhi)
Tandon Associates (Kanpur)
Arinem Consultantcy Services Pvt. Ltd.
Arcop Associates Private Limited, Gk-I, (New Delhi)
Rudraa Associates (Gurgaon)
Sachdeva Consultats (Gurgaon)
SL ENGINEERS
A Complete Solution ofFire Fighting System