More Related Content
Similar to ITM_KDF-TPU600
Similar to ITM_KDF-TPU600 (20)
More from Muhammad Sarfraz
More from Muhammad Sarfraz (14)
ITM_KDF-TPU600
- 1. LAKSON TOBACCO Co. Ltd.
ITM_KDF-TPU600.VSD
ITM- Filter Machine TPU 600 Section
WATT N VOLT
Industrial Automation & Engineering
WATT N VOLT
Industrial Automation & Engineering
18th-km. Ferozepur Road, Lahore Pakistan.
Tel: +92 42 35820595 ,35820296
Fax: +92 42 35820830
E-mail: wnv@wol.net.pk; wnv@wattnvolt.com
Visit us: http://www.wattnvolt.com
- 2. 0
Company Name:Client Name:
WATT N VOLT
Industrial Automation & Engineering
18th-km. Ferozepur Road, Lahore Pakistan.
Tel: +92 42 35820595 ,35820296
Fax: +92 42 35820830
E-mail: wnv@wol.net.pk; wnv@wattnvolt.com
Visit us: http://www.wattnvolt.com
Lakson Tobacco Co.Ltd.
(Sahiwal Factory)
National Highway Qadirabad,
Sahiwal,Pakistan.
Phone: + 92 40 4304119
Dated by:
Folio:
Revised:
4/2/2011
2/33
0
Drawing by:
Checked by:
DWG #:
SARFRAZ
Tahir Rasool
WNV_LKS_002
ITM – Filter Machine (TPU 600 Section) Electrical Schematic Drawing
LEGEND
D:DrawingsLAKSONITM_KDFITM_KDF-TPU600.vsdFile & Directory Name:
Circuit Description:
Title:
1 2 3 4 5 6 7 8 9
O380V400V415V
220V0
EARTH LEAKAGE
PROTECTION CIRCUIT
BREAKER
(RCCB)
(Q)
MAIN CIRCUIT
BREAKER (MCCB)
Magnetic & Thermal
Protection.
(Q)
Miniature Circuit
Breaker
(F)
Motor protection
Circuit Breaker
(Q)
Isolating
Transformer
(T)
Magnetic
Contactor
(KM)
R
Relay or Contactor
Coil
(KA)
vss
Volt Selector
Switch
(VSS)
Panel Light
(H)
Panel cooling Fan
(V)
Socket outlet
230vac 1 phase
(P)
Indication Light
(H)
Emergency Stop
Pushbutton
(S)
Thermal overload
(F)
Mode Selector
Switch
(SW)
Panel Door Switch
(S)
<I <I <I
<I <I <I
Push Button
Normally Close
(B)
Push Button
Normally Open
(B)
Normally Close
Contact
Normally Open
Contact
Proximity Sensor
(B)
+
-
Sig.
123
Line up Terminal
(X)
123
Fusible Terminal
(X)
PLC Module Terminals
LEGEND
9
CODING
12 KA 1
SEQUENCE OF NUMBRING
FUNCTION
SHEET NUMBER
Q = CIRCUIT BREAKER
F = THERMAL OVERLOAD
KM = MOTOR RELAY
KA = AUXILIARY RELAY
H = SIGNAL LIGHT
S = SWITCH/PUSH BUTTON
A = AMPLIFIER
I = PLC INPUT
Q = PLC OUTPUT
WIRE COLORS
3 PHASE SUPPLY 415VAC = BLACK
CONTROL SUPPLY 220VAC = RED
ZERO POTENTIAL 220VAC = BLACK
EARTH = GREEN/YELLOW
CONTROL SUPPLY 24VDC = BLUE
ANALOG SIGNAL = WHITE
INTERLOCKING = ORANGE
VFD CONTROL = BROWN
MATERIALS
FUSES = SIEMENS
MAIN MCCB = SIEMENS
CONTROL RELAYS = SIEMENS
THERMAL OVERLOAD = SIEMENS
CIRCUIT BREAKERS = SIEMENS
TERMINAL BLOCKS = LEGRAND/CONTACLIP
TRANSFORMERS = LUTZE/RIEDEL
- 3. 0
Company Name:Client Name:
WATT N VOLT
Industrial Automation & Engineering
18th-km. Ferozepur Road, Lahore Pakistan.
Tel: +92 42 35820595 ,35820296
Fax: +92 42 35820830
E-mail: wnv@wol.net.pk; wnv@wattnvolt.com
Visit us: http://www.wattnvolt.com
Lakson Tobacco Co.Ltd.
(Sahiwal Factory)
National Highway Qadirabad,
Sahiwal,Pakistan.
Phone: + 92 40 4304119
Dated by:
Folio:
Revised:
4/2/2011
3/33
0
Drawing by:
Checked by:
DWG #:
SARFRAZ
Tahir Rasool
WNV_LKS_002
ITM – Filter Machine (TPU 600 Section) Electrical Schematic Drawing
Main Incoming Circuit
D:DrawingsLAKSONITM_KDFITM_KDF-TPU600.vsdFile & Directory Name:
Circuit Description:
Title:
1 2 3 4 5 6 7 8 9
<I <I <I
Main Incoming Supply
415Vac Neutral + Earth
GROUND
NEUTRAL
L1
L2
L3
N
E
N
PE
MCCB
40-50A
3Q0
10Q1
L2ΎL3Ύ Ύ L1
L2 Ύ L1 ΎΎL3
L1
L2
L3
PRIMARY INPUT
200-600V 3~
SECONDARY
OUTPUT 400V 3~
L3 L1L2
Main Incoming Supply
3 Phase Isolation Auto Transformer
Input 3 phase 200 to 600V
Output 3 phase 400V
3T5
10T3
Ỳ Terminal
Ỳ Terminal
L1
L2
L3
<I <I <I
3Q8
10Q7
L1 L2 L3
3A8
10A7
15
18
25
28
10.6 10.6
Voltage Gaurd
1 3 5
2 4 6
2 4 6
1 3 5
13
14
21
22
L1
L2
L3
CARLO
GAVAZZI
EUY C 400
- 4. 0
Company Name:Client Name:
WATT N VOLT
Industrial Automation & Engineering
18th-km. Ferozepur Road, Lahore Pakistan.
Tel: +92 42 35820595 ,35820296
Fax: +92 42 35820830
E-mail: wnv@wol.net.pk; wnv@wattnvolt.com
Visit us: http://www.wattnvolt.com
Lakson Tobacco Co.Ltd.
(Sahiwal Factory)
National Highway Qadirabad,
Sahiwal,Pakistan.
Phone: + 92 40 4304119
Dated by:
Folio:
Revised:
4/2/2011
4/33
0
Drawing by:
Checked by:
DWG #:
SARFRAZ
Tahir Rasool
WNV_LKS_002
ITM – Filter Machine (TPU 600 Section) Electrical Schematic Drawing
VFD Drives Circuit
D:DrawingsLAKSONITM_KDFITM_KDF-TPU600.vsdFile & Directory Name:
Circuit Description:
Title:
1 2 3 4 5 6 7 8 9
N
PE
<I <I <I
4Q0 (18-25A)
11Q1
2 4 6
1 3 5
13
14
21
22
2
4
6
A1
A2
43KM4 4KM0
L1
L2
L3
13
14
2
4
6
X1.1
3 ~
Motor 1
1.5KW
PE
ART.NO:
09.F0.R11-3429
1.5KW
U V W PE
4M1
11M1
-UzK+UzK
1 2 3 4 PE
X1.11
1 2 3 4
PE
X8.2
X8.21
PA
PB
L1
(L)
L2
(N)
L3
ANTRIEBSTECHNIK
010203
Relay
Output 2
15 9 184
13 19 2010
F0-Series
AC Drive
GND
REF2
FWD
0V
ST
RST
FRQ
COM
RLC
RLB
RLA
Braking Module
Motor
4R0
11R0
4VAR3
56A1
4R9
11R4
Braking
Resistor
3 4
3 4
X1.2
3 ~
Motor 2
1.5KW
PE
ART.NO:
09.F0.R11-3429
1.5KW
U V W PE
4M5
11M3
-UzK+UzK
1 2 3 4 PE
X1.21
1 2 3 4
PE
X8.2
X8.21
PA
PB
L1
(L)
L2
(N)
L3
ANTRIEBSTECHNIK
010203
Relay
Output 2
15 9 184
13 19 2010
F0-Series
AC Drive
GND
REF2
FWD
0V
ST
RST
FRQ
COM
RLC
RLB
RLA
Braking Module
Motor
4R5
11R3
4VAR7
57A1
4R9
11R4
Braking
Resistor
3 4
3 4
6
4
2
To 4VAR7
24Vdc -
From 21.5/Q3.5
31X-
From 24Vdc.3+
16X3+
14
13
4KM0
43KM4
To 4VAR7
From 21.5/Q3.4
To 4VAR7
X8.1
39 40 41
X8.11
39 40 41
X8.111
39 40 41
FREQ1+
FREQ1-
From PLC
Analog Output
PQW 268
4R3
56R5
1
3
2
2 3
11 9
3837
X8.111
3837
X8.11
3837
X8.1
4A2
56A2
DISPLAY 1
RPM MOTOR 1
21.5/Q3.5
24vdc -
24V.31+
24V.31-
25X-
To 5VAR3
24Vdc -
From 21.5/Q3.5
32X-
From 24Vdc.3+
16X3+
14
13
4KM0
43KM4
To 5VAR3
From 21.5/Q3.4
To 5VAR3
X8.1
42 43 44
X8.11
42 43 44
X8.111
42 43 44
FREQ2+
FREQ2-
From PLC
Analog Output
PQW 270
4R7
57R4
1
3
2
2 3
11 9
4A7
57A2
DISPLAY 2
RPM MOTOR 2
24V.31+
24V.31-
- 5. 0
Company Name:Client Name:
WATT N VOLT
Industrial Automation & Engineering
18th-km. Ferozepur Road, Lahore Pakistan.
Tel: +92 42 35820595 ,35820296
Fax: +92 42 35820830
E-mail: wnv@wol.net.pk; wnv@wattnvolt.com
Visit us: http://www.wattnvolt.com
Lakson Tobacco Co.Ltd.
(Sahiwal Factory)
National Highway Qadirabad,
Sahiwal,Pakistan.
Phone: + 92 40 4304119
Dated by:
Folio:
Revised:
4/2/2011
5/33
0
Drawing by:
Checked by:
DWG #:
SARFRAZ
Tahir Rasool
WNV_LKS_002
ITM – Filter Machine (TPU 600 Section) Electrical Schematic Drawing
VFD Drives Circuit
D:DrawingsLAKSONITM_KDFITM_KDF-TPU600.vsdFile & Directory Name:
Circuit Description:
Title:
1 2 3 4 5 6 7 8 9
N
PE
<I <I <I
5Q6 (1-1.6A)
11Q8
2 4 6
1 3 5
13
14
21
22
2 2
4
66
4
A1
A2
43KM5 5KM6
L1
N
13
14
X1.3
3 ~
Motor 3
1.5KW
PE
ART.NO:
09.F0.R11-3429
1.5KW
U V W PE
5M1
11M5
-UzK+UzK
1 2 3 4 PE
X1.31
1 2 3 4
PE
X8.2
X8.21
PA
PB
L1
(L)
L2
(N)
L3
ANTRIEBSTECHNIK
2
4
6
010203
Relay
Output 2
15 9 184
13 19 2010
F0-Series
AC Drive
GND
REF2
FWD
0V
ST
RST
FRQ
COM
RLC
RLB
RLA
Braking Module
Motor
5R0
11R5
5VAR3
58A1
5R4
11R6
Braking
Resistor
5 6
5 6
L1/3.92/4.9
4/4.9
6/4.9
X1.4
3 ~
PLASTICIZER
Pump Motor
1.5KW
PE
ART.NO:
09.F0.R11-3429
1.5KW
U V W PE
5M6
11M8
-UzK+UzK
1 2 3 4 PE
X1.41
1 2 3 4
PE
X8.2
X8.21
ANTRIEBSTECHNIK
010203
Relay
Output 2
15 9 185
13 19 2010
F0-Series
AC Drive
INCH
REF2
FWD
0V
ST
RST
FRQ
COM
RLC
RLB
RLA
Braking Module
Motor
5R5
11R7
7 8
7 8
L1 N
5VAR7
59A1
24V.31-
24Vdc -
From 21.5/Q3.5
33X-
From 24Vdc.3+
16X3+
14
13
4KM0
43KM4
To 5VAR7
From 21.5/Q3.4
To 5VAR7
24V.31+
X8.1
45 46 47
X8.11
45 46 47
X8.111
45 46 47
FREQ3+
FREQ3-
From PLC
Analog Output
PQW 272
5R3
58R4
1
3
2
2 3
11 9
5A3
58A2
DISPLAY 3
RPM MOTOR 3
24Vdc -
From 21.6/Q3.6
34X-
From 24Vdc.3+
16X3+
14
13
4KM0
43KM4
From 21.5/Q3.4
FREQ4+
FREQ4-
From PLC
Analog Output
PQW 274
PUMP+
To PLC
Analog Input
PIW 282
PUMP-
21.6/I1
From PLC
Digital Output
Q3.7
- 6. 0
Company Name:Client Name:
WATT N VOLT
Industrial Automation & Engineering
18th-km. Ferozepur Road, Lahore Pakistan.
Tel: +92 42 35820595 ,35820296
Fax: +92 42 35820830
E-mail: wnv@wol.net.pk; wnv@wattnvolt.com
Visit us: http://www.wattnvolt.com
Lakson Tobacco Co.Ltd.
(Sahiwal Factory)
National Highway Qadirabad,
Sahiwal,Pakistan.
Phone: + 92 40 4304119
Dated by:
Folio:
Revised:
4/2/2011
6/33
0
Drawing by:
Checked by:
DWG #:
SARFRAZ
Tahir Rasool
WNV_LKS_002
ITM – Filter Machine (TPU 600 Section) Electrical Schematic Drawing
DOL Motor Circuit
D:DrawingsLAKSONITM_KDFITM_KDF-TPU600.vsdFile & Directory Name:
Circuit Description:
Title:
1 2 3 4 5 6 7 8 9
N
PE
2
6
4
A1
A2
43KM2 6KM0
13
14
2/5.3
4/5.3
6/5.3
X1.5
3 ~
Brush Motor
1.5KW
PE6M0
12M1
1 2 3
X1.51
1 2 3
<I <I <I6Q0 (1-1.6A)
12Q1
2 4 6
1 3 5
13
14
21
22
2
4
6
A1
A2
43KM3 6KM3
13
14
3 ~
Compressor Motor
1.5KW
PE6M3
12M3
4 5 6
4 5 6
<I <I <I6Q3 (6-10A)
12Q3
2 4 6
1 3 5
13
14
21
22
- 7. 0
Company Name:Client Name:
WATT N VOLT
Industrial Automation & Engineering
18th-km. Ferozepur Road, Lahore Pakistan.
Tel: +92 42 35820595 ,35820296
Fax: +92 42 35820830
E-mail: wnv@wol.net.pk; wnv@wattnvolt.com
Visit us: http://www.wattnvolt.com
Lakson Tobacco Co.Ltd.
(Sahiwal Factory)
National Highway Qadirabad,
Sahiwal,Pakistan.
Phone: + 92 40 4304119
Dated by:
Folio:
Revised:
4/2/2011
7/33
0
Drawing by:
Checked by:
DWG #:
SARFRAZ
Tahir Rasool
WNV_LKS_002
ITM – Filter Machine (TPU 600 Section) Electrical Schematic Drawing
Panel Utility 220v Devices Circuit
D:DrawingsLAKSONITM_KDFITM_KDF-TPU600.vsdFile & Directory Name:
Circuit Description:
Title:
1 2 3 4 5 6 7 8 9
2
6
4
2/6.9
4/6.9
6/6.9
7F1 (4A)
15F1
O380V400V415V
0V220V
Isolation Transformer
for 220V Supply
Input 2 phase 400V
Output 1 phase 220V
L220V
N220V
L1
N
7T1
15T1
101
7F3 (4A)
15F3
1 2 3 4 5 6 7 8
PE
9 10 11 12 14
Panel Cooling
Fan
Panel Light Computer
Socket
7A5
15A4
PE
Comp.
1 ~Charging Line
Discharging
Line
Suction Line
Condenser
Evaporator
CapillaryTube
Filter
PE
PE
Cooling Unit
If Inst.
13
X2
X2
7K6
45KA2
Machine Fanillumination Spray
Room
PE
PE
15 16
15 16
X1.5
X1.51
7A8
15A7
illumination Cylinder
2+3+4
7H8
15H7
7H9
15H8
13
14
7B4
15B4
23
24
- 8. 0
Company Name:Client Name:
WATT N VOLT
Industrial Automation & Engineering
18th-km. Ferozepur Road, Lahore Pakistan.
Tel: +92 42 35820595 ,35820296
Fax: +92 42 35820830
E-mail: wnv@wol.net.pk; wnv@wattnvolt.com
Visit us: http://www.wattnvolt.com
Lakson Tobacco Co.Ltd.
(Sahiwal Factory)
National Highway Qadirabad,
Sahiwal,Pakistan.
Phone: + 92 40 4304119
Dated by:
Folio:
Revised:
4/2/2011
8/33
0
Drawing by:
Checked by:
DWG #:
SARFRAZ
Tahir Rasool
WNV_LKS_002
ITM – Filter Machine (TPU 600 Section) Electrical Schematic Drawing
24VDC & 10VDC Transformer Circuit
D:DrawingsLAKSONITM_KDFITM_KDF-TPU600.vsdFile & Directory Name:
Circuit Description:
Title:
1 2 3 4 5 6 7 8 9
LNPE
+
-
~
~
101
PE
+
_
24vdc-
24vdc+
L220V
N220V
L/7.9
N/7.9
8F1 (2A)
17F1
Prim. 220vac
Sec. 24vdc/10A
8T1
17T2
LNPE
+
-
~
~
+
_
10vdc-
10vdc+
8F4 (1A)
17F5
Prim. 220vac
Sec. 12vdc/300mA
8T6
17T6
32
33
8R9
17R8
1K5
13
14
- 9. 0
Company Name:Client Name:
WATT N VOLT
Industrial Automation & Engineering
18th-km. Ferozepur Road, Lahore Pakistan.
Tel: +92 42 35820595 ,35820296
Fax: +92 42 35820830
E-mail: wnv@wol.net.pk; wnv@wattnvolt.com
Visit us: http://www.wattnvolt.com
Lakson Tobacco Co.Ltd.
(Sahiwal Factory)
National Highway Qadirabad,
Sahiwal,Pakistan.
Phone: + 92 40 4304119
Dated by:
Folio:
Revised:
4/2/2011
9/33
0
Drawing by:
Checked by:
DWG #:
SARFRAZ
Tahir Rasool
WNV_LKS_002
ITM – Filter Machine (TPU 600 Section) Electrical Schematic Drawing
24VDC Distribution & Emergency Stop Circuit
D:DrawingsLAKSONITM_KDFITM_KDF-TPU600.vsdFile & Directory Name:
Circuit Description:
Title:
1 2 3 4 5 6 7 8 9
24vdc +24vdc +/8.4
24vdc -24vdc -/8.4
24vdcSupply
TPUPLCIM153-1
ET200M
24V.1+
24vdcSupply
Input
24V.2+
9F3 (3A)
20F4
24vdcOutputs
Constant
24V.3+
9S5
21A6
9S6
21A7
24vdcOutputs
Switched
24V.4+I15.1
Emergency
Stop
9S6
21S2
1
1X4
X4.1
1
X4.11
1
X4.111
3
3
3
3
11
12
21
22
EmergencyStop
I15.0
9F2 (1A)
20F3
13
14
9F1 (1A)
20F1
13
14
4
X4.1
X4.11
X4.111
4
4
4
X4 2
2
2
2
Upstream
Emergency
Stop
Downstream
Emergency
Stop
EMERGENCY 2
UPSTREAM
EMERGENCY 1
DOWNSTREAM
Page 31.1 Page 33.1
- 10. 0
Company Name:Client Name:
WATT N VOLT
Industrial Automation & Engineering
18th-km. Ferozepur Road, Lahore Pakistan.
Tel: +92 42 35820595 ,35820296
Fax: +92 42 35820830
E-mail: wnv@wol.net.pk; wnv@wattnvolt.com
Visit us: http://www.wattnvolt.com
Lakson Tobacco Co.Ltd.
(Sahiwal Factory)
National Highway Qadirabad,
Sahiwal,Pakistan.
Phone: + 92 40 4304119
Dated by:
Folio:
Revised:
4/2/2011
10/33
0
Drawing by:
Checked by:
DWG #:
SARFRAZ
Tahir Rasool
WNV_LKS_002
ITM – Filter Machine (TPU 600 Section) Electrical Schematic Drawing
MCB’s & Thermal Overload Auxiliary Input Circuit
D:DrawingsLAKSONITM_KDFITM_KDF-TPU600.vsdFile & Directory Name:
Circuit Description:
Title:
1 2 3 4 5 6 7 8 9
24vdc.3+24vdc.3+/9.3
24vdc -24vdc -/9.9
24vdc.2+24vdc.2+/9.2
4X3+
13
14
3Q8
10Q7
13
14
4Q0
11Q1
13
14
5Q6
11Q8
13
14
7F3
15F3
13
14
8F4
17F5
13
14
9F1
20F1
13
14
9F2
20F3
10KA0
A1
A2
22KA2
4X -
5X3+
13
14
6Q0
12Q1
13
14
6Q3
12Q3
13
14
5Q6
56A1
13
14
7F3
57A1
13
14
8F4
58A1
13
14
9F1
59A1
10KA1
A1
A2
22KA3
9X2+
15
18
3A8
10A7
25
28
3A8
10A7
10KA6
A1
A2
22KA7
38X -
5X3+
33
33X4+
X4.1
33
X4.11
25X4.112
21
22
26X4.112
27X4.112
10S3
25S5
10S3.1
25S5.1
26X4.112
29X4.112
10S3.2
25S5.2
X4.112 30
34
X4.11
34
X4.1
34X4
Front Cover
Spare
Spare
MCB’s & Fuses
Auxiliary Inputs
MPCB’s Auxiliary
Inputs
Voltage GaurdDoor Switches
10KA4
A1
A2
22A5
38X -
- 11. 24VDC
6ES7 153-1AA03-0XB0
SIMATIC DP, INTERFACE IM 153-1,
FOR ET 200M, FOR MAX. 8 S7-300
MODULES
PLC MODULE ARRANGEMENT FOR TPU PANEL
I 12.0
I 12.1
I 12.2
I 12.3
I 12.4
I 12.5
I 12.6
I 12.7
I 13.0
I 13.1
I 13.2
I 13.3
I 13.4
I 13.5
I 13.6
I 13.7
M
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
6ES7 321-1BL00-0AA0
SIMATIC S7-300,
DIGITAL INPUT SM
321, OPTICALLY
ISOLATED 32DI, 24 V
DC, 1 X 40 PIN
I 14.0
I 14.1
I 14.2
I 14.3
I 14.4
I 14.5
I 14.6
I 14.7
I 15.0
I 15.1
I 15.2
I 15.3
I 15.4
I 15.5
I 15.6
I 15.7
M
0
Company Name:Client Name:
WATT N VOLT
Industrial Automation & Engineering
18th-km. Ferozepur Road, Lahore Pakistan.
Tel: +92 42 35820595 ,35820296
Fax: +92 42 35820830
E-mail: wnv@wol.net.pk; wnv@wattnvolt.com
Visit us: http://www.wattnvolt.com
Lakson Tobacco Co.Ltd.
(Sahiwal Factory)
National Highway Qadirabad,
Sahiwal,Pakistan.
Phone: + 92 40 4304119
Dated by:
Folio:
Revised:
4/2/2011
11/33
0
Drawing by:
Checked by:
DWG #:
SARFRAZ
Tahir Rasool
WNV_LKS_002
ITM – Filter Machine (TPU 600 Section) Electrical Schematic Drawing
PLC Rack Module Arrangement
D:DrawingsLAKSONITM_KDFITM_KDF-TPU600.vsdFile & Directory Name:
Circuit Description:
Title:
1 2 3 4 5 6 7 8 9
M
L+
E
PROFIBUS-DP
Node = 02
ON
BUS
ADDRESS
64
32
16
8
4
2
1
_
M
SF
BF
ON
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
L+
Q 2.0
Q 2.1
Q 2.2
Q 2.3
Q 2.4
Q 2.5
Q 2.6
Q 2.7
M
L+
Q 3.0
Q 3.1
Q 3.2
Q 3.3
Q 3.4
Q 3.5
Q 3.6
Q 3.7
M
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
6ES7 322-1BL00-0AA0
SIMATIC S7-300,
DIGITAL OUTPUT SM
322, OPTICALLY
ISOLATED, 32DO, 24V
DC, 0.5A, 1 X 40 PIN,
L+
Q 0.0
Q 0.1
Q 0.2
Q 0.3
Q 0.4
Q 0.5
Q 0.6
Q 0.7
M
L+
Q 1.0
Q 1.1
Q 1.2
Q 1.3
Q 1.4
Q 1.5
Q 1.6
Q 1.7
M
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
L+
Q 4.0
Q 4.1
Q 4.2
Q 4.3
Q 4.4
Q 4.5
Q 4.6
Q 4.7
M
L+
Q 5.0
Q 5.1
Q 5.2
Q 5.3
Q 5.4
Q 5.5
Q 5.6
Q 5.7
M
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
6ES7 323-1BL00-0AA0
SIMATIC S7-300,
DIGITAL MODULE SM
323, OPTICALLY
ISOLATED, 16 DI AND
16 DO, 24V DC, 0.5A,
I 16.0
I 16.1
I 16.2
I 16.3
I 16.4
I 16.5
I 16.6
I 16.7
I 17.0
I 17.1
I 17.2
I 17.3
I 17.4
I 17.5
I 17.6
I 17.7
M
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
6ES7 331-1KF02-0AB0
SIMATIC S7-300, ANALOG
INPUT SM 331, OPTICALLY
ISOLATED, 8 AI, 13 BIT
RESOLUTION, U/I/
RESISTANCE/PT100,
U+
I+
S-
M+
M-
CH0
U+
I+
S-
M+
M-
CH1
U+
I+
S-
M+
M-
CH2
U+
I+
S-
M+
M-
CH3
U+
I+
S-
M+
M-
CH4
U+
I+
S-
M+
M-
CH5
U+
I+
S-
M+
M-
CH6
U+
I+
S-
M+
M-
CH7
N9 N11 N12 N13 N14N10
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
6ES7 332-5HD01-0AB0
SIMATIC S7-300,
ANALOG OUTPUT SM
332, OPTICALLY
ISOLATED, 4 AO, U/I;
DIAGNOSTICS;
L+
QV0/QI0
S0+
S0-
M ANA
CH0
M
QV1/QI1
S1+
S1-
M ANA
CH1
QV2/QI2
S2+
S2-
M ANA
CH2
QV3/QI3
S3+
S3-
M ANA
CH3
From PLC CPU X2 DP
Port in FM400+ Panel
24V.1+/9.1
24vdc-/9.1
9
8
7
6
5
4
3
2
1
11A8
52A6
HMI TOUCH DISPLAY
24vdc Supply
To HMI Touch Display
at Machine
PROFIBUS-DP
Node = 00
24V.1+/20.0
24vdc-/20.0
6AV6 643-0CD01-1AX1
MP 277 10" Touch
Position
Switch OFF
Position
Switch OFF
Position
Switch ON
- 12. 0
Company Name:Client Name:
WATT N VOLT
Industrial Automation & Engineering
18th-km. Ferozepur Road, Lahore Pakistan.
Tel: +92 42 35820595 ,35820296
Fax: +92 42 35820830
E-mail: wnv@wol.net.pk; wnv@wattnvolt.com
Visit us: http://www.wattnvolt.com
Lakson Tobacco Co.Ltd.
(Sahiwal Factory)
National Highway Qadirabad,
Sahiwal,Pakistan.
Phone: + 92 40 4304119
Dated by:
Folio:
Revised:
4/2/2011
12/33
0
Drawing by:
Checked by:
DWG #:
SARFRAZ
Tahir Rasool
WNV_LKS_002
ITM – Filter Machine (TPU 600 Section) Electrical Schematic Drawing
Operator Panel Input Circuit
D:DrawingsLAKSONITM_KDFITM_KDF-TPU600.vsdFile & Directory Name:
Circuit Description:
Title:
1 2 3 4 5 6 7 8 9
24vdc.2+24vdc.2+/9.2
15X-
6
6
6
2 3 4 5 6 7 8 9
I12.0 I12.1 I12.2 I12.3 I12.4 I12.5 I12.6 I12.7
Not Used
STOP
MAKER
START
AUXILIARY
DRIVES
STOP
AUXILIARY
DRIVES
RESET
UP/DOWN
IN FEED
ARM
OPEN/CLOSE
COVERS
PLASTICIZER
ON/OFF
OPEN/CLOSE
CYLINDER 1
Not Used
101
6
24vdc -24vdc -/9.9
5X2+
5
5X4
X4.1
5
X4.11
5
X4.111
24vdc.21+
PE
23
PE
PE
X0.1
X0.1
4
5
7X4
7
X4.1
7
X4.11
7
X4.111
12S2
30S2
1
2
9X4
9
X4.1
9
X4.11
9
X4.111
12S3.1
30S4
1
2
12S3
30S3
3
4
8X4
8
X4.1
8
X4.11
8
X4.111
12S4
30S4.1
3
4
10X4
10
X4.1
10
X4.11
10
X4.111
11X4
11
X4.1
11
X4.11
11
X4.111
12S5
30S5
3
4
12X4
12
X4.1
12
X4.11
12
X4.111
12S5.1
30S6
3
4
13X4
13
X4.1
13
X4.11
13
X4.111
12S6
30S7
3
4
14X4
14
X4.1
14
X4.11
14
X4.111
N10
12S6.1
30S8
3
4
- 13. 0
Company Name:Client Name:
WATT N VOLT
Industrial Automation & Engineering
18th-km. Ferozepur Road, Lahore Pakistan.
Tel: +92 42 35820595 ,35820296
Fax: +92 42 35820830
E-mail: wnv@wol.net.pk; wnv@wattnvolt.com
Visit us: http://www.wattnvolt.com
Lakson Tobacco Co.Ltd.
(Sahiwal Factory)
National Highway Qadirabad,
Sahiwal,Pakistan.
Phone: + 92 40 4304119
Dated by:
Folio:
Revised:
4/2/2011
13/33
0
Drawing by:
Checked by:
DWG #:
SARFRAZ
Tahir Rasool
WNV_LKS_002
ITM – Filter Machine (TPU 600 Section) Electrical Schematic Drawing
Operator Panel Input Circuit
D:DrawingsLAKSONITM_KDFITM_KDF-TPU600.vsdFile & Directory Name:
Circuit Description:
Title:
1 2 3 4 5 6 7 8 9
24vdc.21+/12.9
12 13 14 15 16 17 18 19
I13.0 I13.1 I13.2 I13.3 I13.4 I13.5 I13.6 I13.7
Not Used
INCH
PUMP
MOTOR
SPARE SPARE SPARE SPARE SPARE SPARESPARE
-24VDC
COMMON
SUPPLY
20
M
11
15X4
15
X4.1
15
X4.11
15
X4.111
13S2
31S2
3
4
17X4
17
X4.1
17
X4.11
17
X4.111
16X4
16
X4.1
16
X4.11
16
X4.111
18X4
18
X4.1
18
X4.11
18
X4.111
24vdc-
19X4
19
X4.1
19
X4.11
19
X4.111
20X4
20
X4.1
20
X4.11
20
X4.111
21X4
21
X4.1
21
X4.11
21
X4.111
22X4
22
X4.1
22
X4.11
22
X4.111
N10
- 14. 0
Company Name:Client Name:
WATT N VOLT
Industrial Automation & Engineering
18th-km. Ferozepur Road, Lahore Pakistan.
Tel: +92 42 35820595 ,35820296
Fax: +92 42 35820830
E-mail: wnv@wol.net.pk; wnv@wattnvolt.com
Visit us: http://www.wattnvolt.com
Lakson Tobacco Co.Ltd.
(Sahiwal Factory)
National Highway Qadirabad,
Sahiwal,Pakistan.
Phone: + 92 40 4304119
Dated by:
Folio:
Revised:
4/2/2011
14/33
0
Drawing by:
Checked by:
DWG #:
SARFRAZ
Tahir Rasool
WNV_LKS_002
ITM – Filter Machine (TPU 600 Section) Electrical Schematic Drawing
Machine Inputs
D:DrawingsLAKSONITM_KDFITM_KDF-TPU600.vsdFile & Directory Name:
Circuit Description:
Title:
1 2 3 4 5 6 7 8 9
24vdc.2+24vdc.2+/12.9
15X-
24
24
24
22 23 24 25 26 27 28 29
I14.0 I14.1 I14.2 I14.3 I14.4 I14.5 I14.6 I14.7
Not Used
IN FEED
ARM
PLASTICIZER
COVER
CYLINDER 1
FRONT COVER
UP RIGHT
AIR
PRESSURE
SPARE SPARESPARE Not Used
3021
24vdc -24vdc -/12.9
5X2+
23
23X4
X4.1
23
X4.11
N10
25X4
25
X4.1
25
X4.11
3X4.112
26X4
26
X4.1
26
X4.11
6X4.112
27X4
27
X4.1
27
X4.11
9X4.112
28X4
28
X4.1
28
X4.11
12X4.112
29X4
29
X4.1
29
X4.11
15X4.112
30X4
30
X4.1
30
X4.11
18X4.112
31X4
31
X4.1
31
X4.11
21X4.112
32X4
32
X4.1
32
X4.11
24X4.112
1X4.112 2
+ - + -
4 5
+ -
7 8
+ -
10 11 13 14
14B2
32B2
14B3
32B3
14B3.1
32B3.1
14B4
32B4
14S5
32S5 1
3
P
15 17 19 20 22 23
- 15. 0
Company Name:Client Name:
WATT N VOLT
Industrial Automation & Engineering
18th-km. Ferozepur Road, Lahore Pakistan.
Tel: +92 42 35820595 ,35820296
Fax: +92 42 35820830
E-mail: wnv@wol.net.pk; wnv@wattnvolt.com
Visit us: http://www.wattnvolt.com
Lakson Tobacco Co.Ltd.
(Sahiwal Factory)
National Highway Qadirabad,
Sahiwal,Pakistan.
Phone: + 92 40 4304119
Dated by:
Folio:
Revised:
4/2/2011
15/33
0
Drawing by:
Checked by:
DWG #:
SARFRAZ
Tahir Rasool
WNV_LKS_002
ITM – Filter Machine (TPU 600 Section) Electrical Schematic Drawing
Cabinet Inputs
D:DrawingsLAKSONITM_KDFITM_KDF-TPU600.vsdFile & Directory Name:
Circuit Description:
Title:
1 2 3 4 5 6 7 8 9
24vdc.2+/14.9
32 33 34 35 36 37 38 39
I15.0 I15.1 I15.2 I15.3 I15.4 I15.5 I15.6 I15.7
Not Used
Emergency
Stop
External
Emergency Stop
MCB’s & Fuses
Auxiliary Inputs
MPCB’s Auxiliary
Inputs
DOOR
SWITCHES
VOLTAGE
GUARD
SPARESPARE
-24VDC
COMMON
SUPPLY
40
M
31
24vdc.4+/9.4
24vdc-
N10
24vdc.2+
8X2+6X4+
21
24
10KA0
22KA2
21
24
10KA1
22KA3
21
24
10KA4
22A5
1
3
10KA6
22KA7
28X2+
9S6
21S2 11
12
1X200 2X200
- 16. 0
Company Name:Client Name:
WATT N VOLT
Industrial Automation & Engineering
18th-km. Ferozepur Road, Lahore Pakistan.
Tel: +92 42 35820595 ,35820296
Fax: +92 42 35820830
E-mail: wnv@wol.net.pk; wnv@wattnvolt.com
Visit us: http://www.wattnvolt.com
Lakson Tobacco Co.Ltd.
(Sahiwal Factory)
National Highway Qadirabad,
Sahiwal,Pakistan.
Phone: + 92 40 4304119
Dated by:
Folio:
Revised:
4/2/2011
16/33
0
Drawing by:
Checked by:
DWG #:
SARFRAZ
Tahir Rasool
WNV_LKS_002
ITM – Filter Machine (TPU 600 Section) Electrical Schematic Drawing
Cabinet Inputs
D:DrawingsLAKSONITM_KDFITM_KDF-TPU600.vsdFile & Directory Name:
Circuit Description:
Title:
1 2 3 4 5 6 7 8 9
24vdc.2+/15.9
2 3 4 5 6 7 88 9
I16.0 I16.1 I16.2 I16.3 I16.4 I16.5 I16.6 I16.7
Not Used SPARE SPARE
PROGRAMMING
ON/OFF
MAIN
CABINET
DOOR
LINKUP
SIGNAL 1
DOWNSTREAM
LINKUP
SIGNAL 2
DOWNSTREAM
LINKUP
SIGNAL 2
UPSTREAM
LINKUP
SIGNAL 1
UPSTREAM
Not Used
101
N12
24vdc.2+
26X2+
16S4
34S4
13
14 7B4
15B4
23
24
14X2+ 22X2+ 23X2+ 24X2+ 25X2+
X66/30.8 X66/30.8
X66/30.8 X66/30.8
X68/33.8 X68/33.8
X68/33.8X68/33.8
3X200 4X200
- 17. 0
Company Name:Client Name:
WATT N VOLT
Industrial Automation & Engineering
18th-km. Ferozepur Road, Lahore Pakistan.
Tel: +92 42 35820595 ,35820296
Fax: +92 42 35820830
E-mail: wnv@wol.net.pk; wnv@wattnvolt.com
Visit us: http://www.wattnvolt.com
Lakson Tobacco Co.Ltd.
(Sahiwal Factory)
National Highway Qadirabad,
Sahiwal,Pakistan.
Phone: + 92 40 4304119
Dated by:
Folio:
Revised:
4/2/2011
17/33
0
Drawing by:
Checked by:
DWG #:
SARFRAZ
Tahir Rasool
WNV_LKS_002
ITM – Filter Machine (TPU 600 Section) Electrical Schematic Drawing
VFD Fault Inputs
D:DrawingsLAKSONITM_KDFITM_KDF-TPU600.vsdFile & Directory Name:
Circuit Description:
Title:
1 2 3 4 5 6 7 8 9
24vdc.2+/16.9
12 13 14 15 16 17 818 19
I17.0 I17.1 I17.2 I17.3 I17.4 I17.5 I17.6 I17.7
Not Used
FREQUENCY
DRIVE 1
FAULT
FREQUENCY
DRIVE 2
FAULT
FREQUENCY
DRIVE 3
FAULT
FREQUENCY
DRIVE 4
FAULT
SPARE SPARE SPARESPARE
-24VDC
COMMON
SUPPLY
20
M
11
24vdc-
N12
24vdc.2+
10X2+
21
23
4VAR3
56A1
11X2+
21
23
4VAR7
57A1
12X2+
21
23
5VAR2
58A1
13X2+
21
23
5VAR7
59A1
5X200 6X200 7X200 8X200
- 18. 0
Company Name:Client Name:
WATT N VOLT
Industrial Automation & Engineering
18th-km. Ferozepur Road, Lahore Pakistan.
Tel: +92 42 35820595 ,35820296
Fax: +92 42 35820830
E-mail: wnv@wol.net.pk; wnv@wattnvolt.com
Visit us: http://www.wattnvolt.com
Lakson Tobacco Co.Ltd.
(Sahiwal Factory)
National Highway Qadirabad,
Sahiwal,Pakistan.
Phone: + 92 40 4304119
Dated by:
Folio:
Revised:
4/2/2011
18/33
0
Drawing by:
Checked by:
DWG #:
SARFRAZ
Tahir Rasool
WNV_LKS_002
ITM – Filter Machine (TPU 600 Section) Electrical Schematic Drawing
Solenoid Valve Circuit
D:DrawingsLAKSONITM_KDFITM_KDF-TPU600.vsdFile & Directory Name:
Circuit Description:
Title:
1 2 3 4 5 6 7 8 9
24vdc.3+/10.9
2 3 4 5 6 7 88 9
MQ0.7Q0.6Q0.5Q0.4Q0.3Q0.2Q0.1Q0.0
-24VDC
COMMON
SUPPLY
SPARE
COVERS
OPEN
COVERS
CLOSED
SPARE
CYLINDER
2,3,4
CLOSE
CYLINDER 1
CLOSE
IN FEED
ARM UP
IN FEED
ARM DOWN
+24VDC
COMMON
SUPPLY
10
L+
1
24vdc.3+
N11
24vdc.3+/10.9
24vdc-
12
1
1
1
1
PE
40
PE
PE
X0.1
X0
6
7
X3+
X5.1
X5.11
X5.111
X5.1111
24vdc- 24vdc-
2
17
X5
X-
2
X5.111
2
X5.11
2
X5.1
2X5.1111
3
X5
3
X5.1
3
X5.11
3
X5.1111
3
X5.111
1
2
18Y240Y2
4X5.1111
4
X5
4
X5.1
4
X5.11
4
X5.1111
4
X5.111
1
2
18Y340Y3
6X5.1111
5
X5
5
X5.1
5
X5.11
5
X5.1111
5
X5.111
1
2
18Y3.140Y4
8X5.1111
6
X5
6
X5.1
6
X5.11
6
X5.1111
6
X5.111
1
2
18Y440Y4.1
10X5.1111
7
X5
7
X5.1
7
X5.11
7
X5.1111
7
X5.111
1
2
18Y4.140Y5
12X5.1111
8
X5
8
X5.1
8
X5.11
8
X5.1111
8
X5.111
1
2
18Y540Y6
14X5.1111
9
X5
9
X5.1
9
X5.11
9
X5.1111
9
X5.111
1
2
18Y640Y7
16X5.1111
10
X5
10
X5.1
10
X5.11
10
X5.1111
10
X5.111
1
2
18Y6.140Y8
18X5.1111
- 19. 0
Company Name:Client Name:
WATT N VOLT
Industrial Automation & Engineering
18th-km. Ferozepur Road, Lahore Pakistan.
Tel: +92 42 35820595 ,35820296
Fax: +92 42 35820830
E-mail: wnv@wol.net.pk; wnv@wattnvolt.com
Visit us: http://www.wattnvolt.com
Lakson Tobacco Co.Ltd.
(Sahiwal Factory)
National Highway Qadirabad,
Sahiwal,Pakistan.
Phone: + 92 40 4304119
Dated by:
Folio:
Revised:
4/2/2011
19/33
0
Drawing by:
Checked by:
DWG #:
SARFRAZ
Tahir Rasool
WNV_LKS_002
ITM – Filter Machine (TPU 600 Section) Electrical Schematic Drawing
Operator Panel
D:DrawingsLAKSONITM_KDFITM_KDF-TPU600.vsdFile & Directory Name:
Circuit Description:
Title:
1 2 3 4 5 6 7 8 9
24vdc.3+/18.9
12 13 14 15 16 17 818 19
MQ1.7Q1.6Q1.5Q1.4Q1.3Q1.2Q1.1Q1.0
-24VDC
COMMON
SUPPLY
SPARESPARESPARE
SPRAY
ROOM
FAULT
PLASTICIZER
TANK
EMPTY
PLASTICIZER
TANK
FULL
MACHINE
READY
AUXILIARY
DRIVES
ON
+24VDC
COMMON
SUPPLY
20
L+
11
24vdc.3+
N11
24vdc.3+/10.9
24vdc-
13
11
11
11
30
X3+
X5
X5.1
X5.11
X5.111
24vdc- 24vdc-
12
18
X5
X-
31
X4.111
12
X5.11
12
X5.1
13
X5
13
X5.1
13
X5.11
32
X5.111
X1
X2
19H0
41H1
X1
X2
19H2
41H2
X1
X2
19H3
41H3
14
X5
14
X5.1
14
X5.11
33
X5.111
15
X5
15
X5.1
15
X5.11
34
X5.111
X1
X2
19H3.1
41H4
16
X5
16
X5.1
16
X5.11
35
X5.111
17
X5
17
X5.1
17
X5.11
36
X5.111
X1
X2
19H5
41H5
18
X5
18
X5.1
18
X5.11
37
X5.111
19
X5
19
X5.1
19
X5.11
38
X5.111
20
X5
20
X5.1
20
X5.11
39
X5.111
X1
X2
19H4
41H4.1
24VDC
SUPPLY ON
- 20. 0
Company Name:Client Name:
WATT N VOLT
Industrial Automation & Engineering
18th-km. Ferozepur Road, Lahore Pakistan.
Tel: +92 42 35820595 ,35820296
Fax: +92 42 35820830
E-mail: wnv@wol.net.pk; wnv@wattnvolt.com
Visit us: http://www.wattnvolt.com
Lakson Tobacco Co.Ltd.
(Sahiwal Factory)
National Highway Qadirabad,
Sahiwal,Pakistan.
Phone: + 92 40 4304119
Dated by:
Folio:
Revised:
4/2/2011
20/33
0
Drawing by:
Checked by:
DWG #:
SARFRAZ
Tahir Rasool
WNV_LKS_002
ITM – Filter Machine (TPU 600 Section) Electrical Schematic Drawing
Machine Outputs
D:DrawingsLAKSONITM_KDFITM_KDF-TPU600.vsdFile & Directory Name:
Circuit Description:
Title:
1 2 3 4 5 6 7 8 9
24vdc.1+/9.1
22 23 24 25 26 27 828 29
MQ2.7Q2.6Q2.5Q2.4Q2.3Q2.2Q2.1Q2.0
-24VDC
COMMON
SUPPLY
SPARESPARESPARE
PLASTICIZER
TANK
FULL
SAFETY
PLASTICIZER
TANK
SAFETY
PLASTICIZER
TANK
FILL
PLASTICIZER
TANK
FILL
PLASTICIZER
TANK
+24VDC
COMMON
SUPPLY
30
L+
21
N11
24vdc.3+/10.9
24vdc-
21
21
21
X5
X5.1
X5.11
24vdc- 24vdc-
22
19
X5
X-
22
X5.11
22
X5.1
X1
X2
19H5
41H5
1
2
20Y242Y2
4X5.113
24vdc.1+
1X5.113
24vdc+
T0/11.9
24vdc-
T0/11.9
2X5.113
X5.113 6 X5.113 10 X5.113 11 X5.113 12 X5.113 13 X5.113 14
23
X5
23
X5.1
23
X5.11
3
X5.113
24
X5
24
X5.1
24
X5.11
5
X5.113
25
X5
25
X5.1
25
X5.11
7
X5.113
26
X5
26
X5.1
26
X5.11
9
X5.113
27
X5
27
X5.1
27
X5.11
11
X5.113
28
X5
28
X5.1
28
X5.11
13
X5.113
29
X5
29
X5.1
29
X5.11
15
X5.113
30
X5
30
X5.1
30
X5.11
17
X5.113
20R2
42R2
1
2
18Y442Y4
8X5.113
20R2
42R2
- 21. 0
Company Name:Client Name:
WATT N VOLT
Industrial Automation & Engineering
18th-km. Ferozepur Road, Lahore Pakistan.
Tel: +92 42 35820595 ,35820296
Fax: +92 42 35820830
E-mail: wnv@wol.net.pk; wnv@wattnvolt.com
Visit us: http://www.wattnvolt.com
Lakson Tobacco Co.Ltd.
(Sahiwal Factory)
National Highway Qadirabad,
Sahiwal,Pakistan.
Phone: + 92 40 4304119
Dated by:
Folio:
Revised:
4/2/2011
21/33
0
Drawing by:
Checked by:
DWG #:
SARFRAZ
Tahir Rasool
WNV_LKS_002
ITM – Filter Machine (TPU 600 Section) Electrical Schematic Drawing
Motor Control
D:DrawingsLAKSONITM_KDFITM_KDF-TPU600.vsdFile & Directory Name:
Circuit Description:
Title:
1 2 3 4 5 6 7 8 9
24vdc.3+/19.9
32 33 34 35 36 37 838 39
MQ3.7Q3.6Q3.5Q3.4Q3.3Q3.2Q3.1Q3.0
-24VDC
COMMON
SUPPLY
INCH
PUMP DRIVE
FORWARD
PUMP DRIVE
FORWARD
DRIVES 1+2+3
RESET
DRIVE 1+2+3
AND PUMP
DRIVE
POWER SUPPLY
PUMP DRIVE
DELAY
SHUT OFF
DRIVES
1+2+3
BRUSH
MOTOR
VACUUM
PUMP
+24VDC
COMMON
SUPPLY
40
L+
31
24vdc.3+
N11
24vdc.3+/10.9
24vdc-
17X3+
24vdc- 24vdc-
20X-
6KM0
A1
A2
43KM2 6KM3
A1
A2
43KM3 5KM6
A1
A2
43KM521T3
A1
A2
43T3
13
14
10KA4
22A5
(0.6-6S)
To4.2/RST
To4.2/F1+2+3
To5.9/F4
To5.8/I1
4KM0
A1
A2
43KM4
POWER SUPPLY
DRIVES
1+2+3
- 22. 0
Company Name:Client Name:
WATT N VOLT
Industrial Automation & Engineering
18th-km. Ferozepur Road, Lahore Pakistan.
Tel: +92 42 35820595 ,35820296
Fax: +92 42 35820830
E-mail: wnv@wol.net.pk; wnv@wattnvolt.com
Visit us: http://www.wattnvolt.com
Lakson Tobacco Co.Ltd.
(Sahiwal Factory)
National Highway Qadirabad,
Sahiwal,Pakistan.
Phone: + 92 40 4304119
Dated by:
Folio:
Revised:
4/2/2011
22/33
0
Drawing by:
Checked by:
DWG #:
SARFRAZ
Tahir Rasool
WNV_LKS_002
ITM – Filter Machine (TPU 600 Section) Electrical Schematic Drawing
Interface Relays
D:DrawingsLAKSONITM_KDFITM_KDF-TPU600.vsdFile & Directory Name:
Circuit Description:
Title:
1 2 3 4 5 6 7 8 9
22 23 24 25 26 27 828 29
MQ4.7Q4.6Q4.5Q4.4Q4.3Q4.2Q4.1Q4.0
-24VDC
COMMON
SUPPLY
SPARE
CONTROL LOOP
DOWN/UP
STREAM
MACHINE
SPARE
SAMPLING
OR
PLASTICIZER
FLOW LOW
DATA LINE 3
DOWNSTREAM
(if inst.)
DATA LINE 2
DOWNSTREAM
(if inst.)
DATA LINE 0
DOWNSTREAM
(if inst.)
DATA LINE 1
DOWNSTREAM
(if inst.)
+24VDC
COMMON
SUPPLY
30
L+
21
N12
24vdc.3+/10.9
24vdc-
24vdc- 24vdc-
21X-
22KA2
A1
A2
44KA2 22KA3
A1
A2
44KA2.1 22KA4
A1
A2
44KA422KA3.1
A1
A2
44KA3
22X-
22KA4.1
A1
A2
44KA5 22KA5
A1
A2
44KA6 22KA6
A1
A2
44KA722KA5.1
A1
A2
44KA6.1
- 23. 0
Company Name:Client Name:
WATT N VOLT
Industrial Automation & Engineering
18th-km. Ferozepur Road, Lahore Pakistan.
Tel: +92 42 35820595 ,35820296
Fax: +92 42 35820830
E-mail: wnv@wol.net.pk; wnv@wattnvolt.com
Visit us: http://www.wattnvolt.com
Lakson Tobacco Co.Ltd.
(Sahiwal Factory)
National Highway Qadirabad,
Sahiwal,Pakistan.
Phone: + 92 40 4304119
Dated by:
Folio:
Revised:
4/2/2011
23/33
0
Drawing by:
Checked by:
DWG #:
SARFRAZ
Tahir Rasool
WNV_LKS_002
ITM – Filter Machine (TPU 600 Section) Electrical Schematic Drawing
Spare Outputs
D:DrawingsLAKSONITM_KDFITM_KDF-TPU600.vsdFile & Directory Name:
Circuit Description:
Title:
1 2 3 4 5 6 7 8 9
32 33 34 35 36 37 838 39
MQ5.7Q5.6Q5.5Q5.4Q5.3Q5.2Q5.1Q5.0
-24VDC
COMMON
SUPPLY
SPARESPARESPARESPARESPARESPARE
COOLING
UNIT
SPARE
+24VDC
COMMON
SUPPLY
40
L+
31
N12
24vdc.3+/10.9
24vdc-
24vdc- 24vdc-
29X-
22KA2
A1
A2
45KA2
1X201 2X201 3X201 4X201 5X201 6X201 7X201
- 24. 0
Company Name:Client Name:
WATT N VOLT
Industrial Automation & Engineering
18th-km. Ferozepur Road, Lahore Pakistan.
Tel: +92 42 35820595 ,35820296
Fax: +92 42 35820830
E-mail: wnv@wol.net.pk; wnv@wattnvolt.com
Visit us: http://www.wattnvolt.com
Lakson Tobacco Co.Ltd.
(Sahiwal Factory)
National Highway Qadirabad,
Sahiwal,Pakistan.
Phone: + 92 40 4304119
Dated by:
Folio:
Revised:
4/2/2011
24/33
0
Drawing by:
Checked by:
DWG #:
SARFRAZ
Tahir Rasool
WNV_LKS_002
ITM – Filter Machine (TPU 600 Section) Electrical Schematic Drawing
Analog Inputs
D:DrawingsLAKSONITM_KDFITM_KDF-TPU600.vsdFile & Directory Name:
Circuit Description:
Title:
1 2 3 4 5 6 7 8 9
10vdc.+/8.9
N13
10vdc.+
10vdc.-/8.9 10vdc.-
17
X8.1
17
X8.11
17
X8.111
18
X8.1
18
X8.11
18
X8.111
2 3 4 5
U+ I+ S- M+ M-
1
PIW 268
CH0
FREQUENCY DRIVE 1
SPEED CONTROL
7 8 9 10
U+ I+ S- M+ M-
6
PIW 270
CH1
FREQUENCY DRIVE 2
SPEED CONTROL
10KΏ
SPEED
POTENTIOMETER
10KΏ
(WH)
1 3
2
V+ V-
(BR)
19
X8.111
20 21
19
X8.11
20 21
19
X8.1
20 21
24R3
50R2
Example Connection for
Duplex PT100 &
4 wire current Transducer
4-20mA
L+ M
10KΏ
SPEED
POTENTIOMETER
10KΏ
(WH)
1 3
2
V+ V-
(BR)
22
X8.111
23 24
22
X8.11
23 24
22
X8.1
23 24
24R5
50R4
Example Connection for
Duplex PT100 &
4 wire current Transducer
4-20mA
L+ M
10vdc.+
10vdc.-
- 25. 0
Company Name:Client Name:
WATT N VOLT
Industrial Automation & Engineering
18th-km. Ferozepur Road, Lahore Pakistan.
Tel: +92 42 35820595 ,35820296
Fax: +92 42 35820830
E-mail: wnv@wol.net.pk; wnv@wattnvolt.com
Visit us: http://www.wattnvolt.com
Lakson Tobacco Co.Ltd.
(Sahiwal Factory)
National Highway Qadirabad,
Sahiwal,Pakistan.
Phone: + 92 40 4304119
Dated by:
Folio:
Revised:
4/2/2011
25/33
0
Drawing by:
Checked by:
DWG #:
SARFRAZ
Tahir Rasool
WNV_LKS_002
ITM – Filter Machine (TPU 600 Section) Electrical Schematic Drawing
Analog Inputs
D:DrawingsLAKSONITM_KDFITM_KDF-TPU600.vsdFile & Directory Name:
Circuit Description:
Title:
1 2 3 4 5 6 7 8 9
10vdc.+/24.9
N13
10vdc.-/24.9
12 13 14 15
U+ I+ S- M+ M-
11
PIW 272
CH2
FREQUENCY DRIVE 3
SPEED CONTROL
17 18 19 20
U+ I+ S- M+ M-
16
PIW 274
CH3
PLASTICIZER PUMP DRIVE
SPEED CONTROL
10KΏ
SPEED
POTENTIOMETER
10KΏ
(WH)
1 3
2
V+ V-
(BR)
25
X8.111
26 27
25
X8.11
26 27
25
X8.1
26 27
25R3
50R6
Example Connection for
Duplex PT100 &
4 wire current Transducer
4-20mA
L+ M
10KΏ
SPEED
POTENTIOMETER
10KΏ
(WH)
1 3
2
V+ V-
(BR)
28
X8.111
29 30
28
X8.11
29 30
28
X8.1
29 30
25R5
50R7
Example Connection for
Duplex PT100 &
4 wire current Transducer
4-20mA
L+ M
- 26. 0
Company Name:Client Name:
WATT N VOLT
Industrial Automation & Engineering
18th-km. Ferozepur Road, Lahore Pakistan.
Tel: +92 42 35820595 ,35820296
Fax: +92 42 35820830
E-mail: wnv@wol.net.pk; wnv@wattnvolt.com
Visit us: http://www.wattnvolt.com
Lakson Tobacco Co.Ltd.
(Sahiwal Factory)
National Highway Qadirabad,
Sahiwal,Pakistan.
Phone: + 92 40 4304119
Dated by:
Folio:
Revised:
4/2/2011
26/33
0
Drawing by:
Checked by:
DWG #:
SARFRAZ
Tahir Rasool
WNV_LKS_002
ITM – Filter Machine (TPU 600 Section) Electrical Schematic Drawing
Analog Inputs
D:DrawingsLAKSONITM_KDFITM_KDF-TPU600.vsdFile & Directory Name:
Circuit Description:
Title:
1 2 3 4 5 6 7 8 9
24vdc.2+/17.9
N13
24vdc.-/17.9
13
X8.2
13
X8.21
14
X8.2
14
X8.21
22 23 24 25
U+ I+ S- M+ M-
21
PIW 276
CH4
PLASTICIZER
LEVEL
27 28 29 30
U+ I+ S- M+ M-
26
PIW 278
CH5
ANALOG FLOW
SIGNAL
(BK)
V+
V-
(BL)
15
X8.21
16 17
15
X8.2
16 17
26B3
51B3
Example Connection for
Duplex PT100 &
4 wire current Transducer
4-20mA
L+ M
(BR)
V+ V-
(GN)
26B7
51B5
Example Connection for
Duplex PT100 &
4 wire current Transducer
4-20mA
L+ M
0V+
(BR)
24vdc.2+
24vdc.-
X2+ 15 X- 24
X8.212 2X8.212 1
FLOW
DETECTOR
X- 36
X2+ 27
2 1 5 6
23 24 252122
X8.21
23 24 252122
X8.2
X8 28 29 30 31
(YE)
(WH)
- 27. 0
Company Name:Client Name:
WATT N VOLT
Industrial Automation & Engineering
18th-km. Ferozepur Road, Lahore Pakistan.
Tel: +92 42 35820595 ,35820296
Fax: +92 42 35820830
E-mail: wnv@wol.net.pk; wnv@wattnvolt.com
Visit us: http://www.wattnvolt.com
Lakson Tobacco Co.Ltd.
(Sahiwal Factory)
National Highway Qadirabad,
Sahiwal,Pakistan.
Phone: + 92 40 4304119
Dated by:
Folio:
Revised:
4/2/2011
27/33
0
Drawing by:
Checked by:
DWG #:
SARFRAZ
Tahir Rasool
WNV_LKS_002
ITM – Filter Machine (TPU 600 Section) Electrical Schematic Drawing
Analog Inputs
D:DrawingsLAKSONITM_KDFITM_KDF-TPU600.vsdFile & Directory Name:
Circuit Description:
Title:
1 2 3 4 5 6 7 8 9
N13
32 33 34 35
U+ I+ S- M+ M-
31
PIW 280
CH6
TACHO SIGNAL
FROM MAKER
37 38 39 40
U+ I+ S- M+ M-
36
PIW 282
CH7
SIGNAL FROM
PLASTICIZER PUMP DRIVE
13
X67
14 15
Example Connection for
Duplex PT100 &
4 wire current Transducer
4-20mA
L+ M
Example Connection for
Duplex PT100 &
4 wire current Transducer
4-20mA
L+ M
-
TACHO
+
Pump+ /5.8
Pump- /5.8
From Drive
5VAR7
- 28. 0
Company Name:Client Name:
WATT N VOLT
Industrial Automation & Engineering
18th-km. Ferozepur Road, Lahore Pakistan.
Tel: +92 42 35820595 ,35820296
Fax: +92 42 35820830
E-mail: wnv@wol.net.pk; wnv@wattnvolt.com
Visit us: http://www.wattnvolt.com
Lakson Tobacco Co.Ltd.
(Sahiwal Factory)
National Highway Qadirabad,
Sahiwal,Pakistan.
Phone: + 92 40 4304119
Dated by:
Folio:
Revised:
4/2/2011
28/33
0
Drawing by:
Checked by:
DWG #:
SARFRAZ
Tahir Rasool
WNV_LKS_002
ITM – Filter Machine (TPU 600 Section) Electrical Schematic Drawing
Analog Outputs
D:DrawingsLAKSONITM_KDFITM_KDF-TPU600.vsdFile & Directory Name:
Circuit Description:
Title:
1 2 3 4 5 6 7 8 9
N14
+24VDC
COMMON
SUPPLY
L+
1
24vdc.2+/9.2
Not Used
2 543
MANAS0-S0+QV0 / QI0
6
CH0
PQW 268
SPEED CONTROL
DRIVE 1
987
MANAS1-S1+QV1 / QI1
10
CH1
PQW 270
SPEED CONTROL
DRIVE 2
Example Connection for
4-20mA Current Output
RLoad <500R
FREQ1+
FREQ1-
To Drive 1
4VAR3
Example Connection for
4-20mA Current Output
RLoad <500R
FREQ2+
FREQ2-
To Drive 2
4VAR7
- 29. 0
Company Name:Client Name:
WATT N VOLT
Industrial Automation & Engineering
18th-km. Ferozepur Road, Lahore Pakistan.
Tel: +92 42 35820595 ,35820296
Fax: +92 42 35820830
E-mail: wnv@wol.net.pk; wnv@wattnvolt.com
Visit us: http://www.wattnvolt.com
Lakson Tobacco Co.Ltd.
(Sahiwal Factory)
National Highway Qadirabad,
Sahiwal,Pakistan.
Phone: + 92 40 4304119
Dated by:
Folio:
Revised:
4/2/2011
29/33
0
Drawing by:
Checked by:
DWG #:
SARFRAZ
Tahir Rasool
WNV_LKS_002
ITM – Filter Machine (TPU 600 Section) Electrical Schematic Drawing
Analog Outputs
D:DrawingsLAKSONITM_KDFITM_KDF-TPU600.vsdFile & Directory Name:
Circuit Description:
Title:
1 2 3 4 5 6 7 8 9
Not Used
19
24vdc-
-24VDC
COMMON
SUPPLY
20131211
MANAS2-S2+QV2 / QI2
14
CH2
PQW 272
SPEED CONTROL
DRIVE 3
171615
MANAS3-S3+QV3 / QI3
18
CH3
PQW 274
SPEED CONTROL
PUMP DRIVE
Example Connection for
4-20mA Current Output
RLoad <500R
FREQ3+
FREQ3-
To Drive 3
5VAR3
Example Connection for
4-20mA Current Output
RLoad <500R
FREQ4+
FREQ4-
To PUMP Drive
5VAR7
N14
- 30. 0
Company Name:Client Name:
WATT N VOLT
Industrial Automation & Engineering
18th-km. Ferozepur Road, Lahore Pakistan.
Tel: +92 42 35820595 ,35820296
Fax: +92 42 35820830
E-mail: wnv@wol.net.pk; wnv@wattnvolt.com
Visit us: http://www.wattnvolt.com
Lakson Tobacco Co.Ltd.
(Sahiwal Factory)
National Highway Qadirabad,
Sahiwal,Pakistan.
Phone: + 92 40 4304119
Dated by:
Folio:
Revised:
4/2/2011
30/33
0
Drawing by:
Checked by:
DWG #:
SARFRAZ
Tahir Rasool
WNV_LKS_002
ITM – Filter Machine (TPU 600 Section) Electrical Schematic Drawing
Linkup TPU600 Upstream
D:DrawingsLAKSONITM_KDFITM_KDF-TPU600.vsdFile & Directory Name:
Circuit Description:
Title:
1 2 3 4 5 6 7 8 9
EMERGENCY
STOP TO
UPSTREAM
MACHINE
1
X65
2
30A0
65A1
PREVIOUS
MACHINE
CONTROL
LOOP TO
UPSTREAM
MACHINE
3 4
DATA LINES
(If inst.)
5 6 7 8 9 10
SPARE
11 12 13 14 15 16 PE
GROUND
GND
23
24
9S4.1
21A7
41
44
22KA6
44KA7
- 31. 0
Company Name:Client Name:
WATT N VOLT
Industrial Automation & Engineering
18th-km. Ferozepur Road, Lahore Pakistan.
Tel: +92 42 35820595 ,35820296
Fax: +92 42 35820830
E-mail: wnv@wol.net.pk; wnv@wattnvolt.com
Visit us: http://www.wattnvolt.com
Lakson Tobacco Co.Ltd.
(Sahiwal Factory)
National Highway Qadirabad,
Sahiwal,Pakistan.
Phone: + 92 40 4304119
Dated by:
Folio:
Revised:
4/2/2011
31/33
0
Drawing by:
Checked by:
DWG #:
SARFRAZ
Tahir Rasool
WNV_LKS_002
ITM – Filter Machine (TPU 600 Section) Electrical Schematic Drawing
Linkup Upstream TPU600
D:DrawingsLAKSONITM_KDFITM_KDF-TPU600.vsdFile & Directory Name:
Circuit Description:
Title:
1 2 3 4 5 6 7 8 9
EMERGENCY
STOP FROM
UPSTREAM
MACHINE
30A0
65A1
PREVIOUS
MACHINE
CONTROL
LOOP FROM
UPSTREAM
MACHINE
DATA LINES
(If inst.)
2
X67
1
GROUND
43PE
PNOZ-Z
UPSTREAM/9.4
EMERGENCY2
GND
X0 29
5 6 7 8
LINKUP
SIGNAL 1
UPSTREAM
9 10
LINKUP
SIGNAL 2
UPSTREAM
11 12
SPARE
13 14 15 16
X66/16.5
X66/16.5
X66/16.6
X66/16.6
- 32. 0
Company Name:Client Name:
WATT N VOLT
Industrial Automation & Engineering
18th-km. Ferozepur Road, Lahore Pakistan.
Tel: +92 42 35820595 ,35820296
Fax: +92 42 35820830
E-mail: wnv@wol.net.pk; wnv@wattnvolt.com
Visit us: http://www.wattnvolt.com
Lakson Tobacco Co.Ltd.
(Sahiwal Factory)
National Highway Qadirabad,
Sahiwal,Pakistan.
Phone: + 92 40 4304119
Dated by:
Folio:
Revised:
4/2/2011
32/33
0
Drawing by:
Checked by:
DWG #:
SARFRAZ
Tahir Rasool
WNV_LKS_002
ITM – Filter Machine (TPU 600 Section) Electrical Schematic Drawing
Linkup TPU600 Downstream
D:DrawingsLAKSONITM_KDFITM_KDF-TPU600.vsdFile & Directory Name:
Circuit Description:
Title:
1 2 3 4 5 6 7 8 9
EMERGENCY
STOP TO
DOWNSTREAM
MACHINE
1
X67
2
32A0
67A1
NEXT
MACHINE
CONTROL
LOOP TO
DOWNSTREAM
MACHINE
3 4
DATA LINES
(If inst.)
5 6 7 8 9 10
SPARE
11 12 13 14 15 16 PE
GROUND
GND
23
24
9S4
21A6
31
34
22KA5.1
44KA6.1
SPARE
TACHO SIGNAL
MAKER
SAMPLING
PLASTICIZER
LOW SIGNAL
(if inst.)
13
14
22KA2
44KA2
23
24
22KA3
44KA2.1
33
34
22KA3.1
44KA3
43
44
22KA4.1
44KA5
DATA 1 /33.0
DATA 2 /33.0
DATA 3 /33.0
DATA 4 /33.0
11
14
22KA4.1
44KA5
21
24
22KA5
44KA6
-
TACHO
+
103
- 33. 0
Company Name:Client Name:
WATT N VOLT
Industrial Automation & Engineering
18th-km. Ferozepur Road, Lahore Pakistan.
Tel: +92 42 35820595 ,35820296
Fax: +92 42 35820830
E-mail: wnv@wol.net.pk; wnv@wattnvolt.com
Visit us: http://www.wattnvolt.com
Lakson Tobacco Co.Ltd.
(Sahiwal Factory)
National Highway Qadirabad,
Sahiwal,Pakistan.
Phone: + 92 40 4304119
Dated by:
Folio:
Revised:
4/2/2011
33/33
0
Drawing by:
Checked by:
DWG #:
SARFRAZ
Tahir Rasool
WNV_LKS_002
ITM – Filter Machine (TPU 600 Section) Electrical Schematic Drawing
Linkup Downstream TPU600
D:DrawingsLAKSONITM_KDFITM_KDF-TPU600.vsdFile & Directory Name:
Circuit Description:
Title:
1 2 3 4 5 6 7 8 9
EMERGENCY
STOP FROM
DOWNSTREAM
MACHINE
32A0
67A1
NEXT
MACHINE
CONTROL
LOOP FROM
DOWNSTREAM
MACHINE
DATA LINES
(If inst.)
2
X68
1
GROUND
43PE
PNOZ-Z
DOWNSTREAM/9.4
EMERGENCY1
GND
X0 28
5 6 7 8
LINKUP
SIGNAL 1
DOWNSTREAM
9 10
LINKUP
SIGNAL 2
DOWNSTREAM
11 12
SPARE
13 14 15 16
X68/16.7
X68/16.7
X68/16.8
X66/16.8
DATA 1 /32.9
DATA 2 /32.9
DATA 3 /32.9
DATA 4 /32.9