Application Flow Sizing and Order Code Configuration
1. Print date: 29.04.2014 11:58 AM
Applicator®: 10.16.05 / 133
- 1 / 7 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Main
Timestamp: --- Review number: ---
Sales order number:
Sizing Sheet
General Parameters
Fluid Propane (Gas) Ref. Temperature 0 °C
State Gas Ref. Pressure 1.013 bar_a
Character Clean Atmospheric Pressure 1.0132 bar_a
Abrasivity Not abrasive Standard EN/DIN/ISO
Fluid Group (PED) Dangerous Fluid (Fluid group 1)
Operating Conditions
minimum nominal maximum
Requested Flow 18 780 1 229 Nm3/h
Pressure 1.2 bar_g
Temperature 30 °C
Density 4.0131 kg/m3
Viscosity 0.00845 cP
Z-factor 0.9649
Sound Velocity 248.7 m/s
Pressure (min/max) 1.2 1.2 bar_g
Temp. (min/max) 30 30 °C
Flowmeter : t-mass 65I
Flow Principle Thermal (t-mass)
Meter Size DN 150
Minimum Flow 17.108 Nm3/h
Calibrated Flow 1 710.824 Nm3/h
Maximum Flow 3 421.65 Nm3/h
Material (sensor) * SS 1.4404 / 316L
Process connection* G 1 A ISO 228 / 1.4404 /316L Thread
PED category ** : Application meets PED (Art.3.3)
Extended order code
Qty Item Description Extended order code
1 Flowmeter t-mass 65I 65I-20AB
1 Accessory Mounting boss - DK6MB DK6MB-B
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissible
pressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.
2. Print date: 29.04.2014 11:58 AM
Applicator®: 10.16.05 / 133
- 2 / 7 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Main
Timestamp: --- Review number: ---
Sales order number:
Sizing Sheet
Sizing and Calculated Results
minimum nominal maximum
Requested Flow 18 780 1 229 Nm3/h
Pressure loss 9.08E-6 0.01 0.04 mbar
Velocity (meas. tube) 0.127 5.52 8.697 m/s
Measured error Mass*** 14.3 1.5 1.5 %
Reynolds No. 9 574 414 858 653 668
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
Attention for Flow! Device is used in non-ideal application conditions.
3. Print date: 29.04.2014 11:58 AM
Applicator®: 10.16.05 / 133
- 3 / 7 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Main
Timestamp: --- Review number: ---
Sales order number:
Fluid properties sheet
Fluid
Fluid name Propane (Gas) State Gas
Chemical formula CH3-CH2-CH3 Calculation standard NEL
Fluid description
Medium character Clean
Fluid group (PED) Dangerous Fluid (Fluid group 1)
Fluid stability Stable
Gas mixture
Component
Fraction
1 Propane (Gas) 100 Mole% 100 Mass%
2 0 Mole% 0 Mass%
3 0 Mole% 0 Mass%
4 0 Mole% 0 Mass%
5 0 Mole% 0 Mass%
6 0 Mole% 0 Mass%
7 0 Mole% 0 Mass%
8 0 Mole% 0 Mass%
Basic fluid parameters
Tc (Critical temperature) 96.69 °C
Pc (Critical pressure) 42.47 bar
Rho_c (Critical density) 217 kg/m3
Tm (Melting point) -187.7 °C
Tb (Boiling point) -42.11 °C
Calculated results
Density nom. 4.0131 kg/m3
Molar mass 44.096 kg/kmol
Z-factor nom. 0.9649
Viscosity nom. 0.00845 cP
Sound velocity nom. 248.7 m/s
Thermal capacity nom. 1.742 kJ/(kg*K)
Heat conductivity nom. 0.018 W/(m K)
Vapor pressure nom. 10.815 bar_a
Pressure nom. 1.2 bar_g
Temperature nom. 30 °C
Reference values: Normal conditions (SI): Standard conditions (US):
Atmospheric pressure 1.0132 bar_a
Density normal 2.0122 kg/m3
Temperature 0 °C
Pressure 1.0132 bar_a
Atmospheric pressure 1.0132 bar_a
Density standard 1.9005 kg/m3
Temperature 59 °F
Pressure 14.696 psi_a
4. Print date: 29.04.2014 11:58 AM
Applicator®: 10.16.05 / 133
- 4 / 7 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Main
Timestamp: --- Review number: ---
Sales order number:
Installation sheet
Flowmeter / Accessories
Extended order code
Qty Item Description Extended order code
1 Flowmeter t-mass 65I 65I-20AB
1 Accessory Mounting boss - DK6MB DK6MB-B
Installation data :
Insertion depth X (scale value) 160.49 mm
Insertion tube length 235 mm
Pipe inner diameter 20°C 158.3 mm
Duct Installation Horizontal
Duct internal height
Duct internal width
Wall thickness 5 mm
C1 = Height process connection 60 mm
C2 = Height sensor connection 46 mm
C3 = Height ball valve 0 mm
C = Total height of connection 106 mm
A= Internal diameter or internal height (duct vertical installation) or internal width (duct horizontal installation)
B= Wall thickness
C= Height of connection
*The Enduser is responsible for the correct selection of the piping. Applicator does not calculate necessary pipe wall thickness according to application
data. Endress + Hauser takes no liability for the suitability of the pipe dimensions.
Attention for Flow! Device is used in non-ideal application conditions.
5. Print date: 29.04.2014 11:58 AM
Applicator®: 10.16.05 / 133
- 5 / 7 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Main
Timestamp: --- Review number: ---
Sales order number:
Tri-Size Sheet
General Parameters
Fluid Propane (Gas) Ref. Temperature 0 °C
State Gas Ref. Pressure 1.013 bar_a
Character Clean Atmospheric Pressure 1.0132 bar_a
Abrasivity Not abrasive Standard EN/DIN/ISO
Fluid Group (PED) Dangerous Fluid (Fluid group 1)
Sizing and Calculated Results
Next Smaller Size Current Size Next Bigger Size
Flow meter t-mass 65I t-mass 65I t-mass 65I
Flow Principle Thermal (t-mass) Thermal (t-mass) Thermal (t-mass)
Meter Size DN 100 DN 150 DN 200
Process connection* G 1 A ISO 228 / 1.4404 /316L G 1 A ISO 228 / 1.4404 /316L G 1 A ISO 228 / 1.4404 /316L
Minimum Flow 7.427 17.108 29.85 Nm3/h
Calibrated Flow 742.698 1 710.824 2 985.049 Nm3/h
Maximum Flow 1 485.4 3 421.65 5 970.1 Nm3/h
Pressure loss at req. Flow min. 6.42E-5 9.08E-6 2.49E-6 mbar
Pressure loss at req. Flow nom. 0.11 0.01 4.14E-3 mbar
Pressure loss at req. Flow max. 0.27 0.04 0.01 mbar
Velocity (meas. tube) at req. Flow min. 0.293 0.127 0.073 m/s
Velocity (meas. tube) at req. Flow nom. 12.72 5.52 3.164 m/s
Velocity (meas. tube) at req. Flow max. 20.03 8.697 4.985 m/s
Meas. error Mass at req. Flow min.*** 6.19 14.3 n.a. %
Meas. error Mass at req. Flow nom.*** 1.85 1.5 1.5 %
Meas. error Mass at req. Flow max.*** n.a. 1.5 1.5 %
Reynolds No. 629 646 414 858 314 070
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
6. Print date: 29.04.2014 11:58 AM
Applicator®: 10.16.05 / 133
- 6 / 7 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Main
Timestamp: --- Review number: ---
Sales order number:
Chart Sheet
Flowmeter : t-mass 65I
Flow Principle Thermal (t-mass)
Meter Size DN 150
Minimum Flow 17.108 Nm3/h
Calibrated Flow 1 710.824 Nm3/h
Maximum Flow 3 421.65 Nm3/h
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
7. Print date: 29.04.2014 11:58 AM
Applicator®: 10.16.05 / 133
- 7 / 7 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Main
Timestamp: --- Review number: ---
Sales order number:
Corrosion Information
General Parameters
Fluid Propane (Gas) Abrasivity Not abrasive
State Gas
Character Clean Flow Principle Thermal (t-mass)
Interpretation of Data, (M) Material:
A: resistant, 0.05 mm/y (0.002 inches/y)
B: insufficient resistant, 0.5 mm/y (0.02 inches/y)
C: not resistant, 1.3 mm/y (0.05 inches/y)
NR: not recommended
U: unknown
Interpretation of Data, (P) Plastics:
A: resistant, 15% vol. Swelling/y; 15% Loss of Tensile Strength/y
B: insufficient resistant, 30% vol. Swelling/y; 30% Loss of Tensile Strength/y
C: not resistant, 50% vol. Swelling/y; 60% Loss of Tensile Strength/y
NR: not recommended
U: unknown
Temperature
Material (Sensor) * minimum30°C nominal : 30°C maximum : 30°C
(M) CF3M - A 351 A A A
(P) EPDM U U U
(M) Alloy C22/2.4602 A A A
(P) Kalrez A A A
(P) PEEK C C C
(P) PVDF A A A
(M) Stainless steel 316L/316/1.4404 A A A
(P) Viton A A A
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
8. Print date: 29.04.2014 12:00 PM
Applicator®: 10.16.05 / 133
- 1 / 7 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-KHX
Timestamp: --- Review number: ---
Sales order number:
Sizing Sheet
General Parameters
Fluid Propane (Gas) Ref. Temperature 0 °C
State Gas Ref. Pressure 1.013 bar_a
Character Clean Atmospheric Pressure 1.0132 bar_a
Abrasivity Not abrasive Standard EN/DIN/ISO
Fluid Group (PED) Dangerous Fluid (Fluid group 1)
Operating Conditions
minimum nominal maximum
Requested Flow 18 780 1 229 Nm3/h
Pressure 1.2 bar_g
Temperature 30 °C
Density 4.0131 kg/m3
Viscosity 0.00845 cP
Z-factor 0.9649
Sound Velocity 248.7 m/s
Pressure (min/max) 1.2 1.2 bar_g
Temp. (min/max) 30 30 °C
Flowmeter : t-mass 65I
Flow Principle Thermal (t-mass)
Meter Size DN 150
Minimum Flow 17.108 Nm3/h
Calibrated Flow 1 710.824 Nm3/h
Maximum Flow 3 421.65 Nm3/h
Material (sensor) * SS 1.4404 / 316L
Process connection* G 1 A ISO 228 / 1.4404 /316L Thread
PED category ** : Application meets PED (Art.3.3)
Extended order code
Qty Item Description Extended order code
1 Flowmeter t-mass 65I 65I-20AB
1 Accessory Mounting boss - DK6MB DK6MB-B
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissible
pressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.
9. Print date: 29.04.2014 12:00 PM
Applicator®: 10.16.05 / 133
- 2 / 7 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-KHX
Timestamp: --- Review number: ---
Sales order number:
Sizing Sheet
Sizing and Calculated Results
minimum nominal maximum
Requested Flow 18 780 1 229 Nm3/h
Pressure loss 9.08E-6 0.01 0.04 mbar
Velocity (meas. tube) 0.127 5.52 8.697 m/s
Measured error Mass*** 14.3 1.5 1.5 %
Reynolds No. 9 574 414 858 653 668
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
Attention for Flow! Device is used in non-ideal application conditions.
10. Print date: 29.04.2014 12:00 PM
Applicator®: 10.16.05 / 133
- 3 / 7 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-KHX
Timestamp: --- Review number: ---
Sales order number:
Fluid properties sheet
Fluid
Fluid name Propane (Gas) State Gas
Chemical formula CH3-CH2-CH3 Calculation standard NEL
Fluid description
Medium character Clean
Fluid group (PED) Dangerous Fluid (Fluid group 1)
Fluid stability Stable
Gas mixture
Component
Fraction
1 Propane (Gas) 100 Mole% 100 Mass%
2 0 Mole% 0 Mass%
3 0 Mole% 0 Mass%
4 0 Mole% 0 Mass%
5 0 Mole% 0 Mass%
6 0 Mole% 0 Mass%
7 0 Mole% 0 Mass%
8 0 Mole% 0 Mass%
Basic fluid parameters
Tc (Critical temperature) 96.69 °C
Pc (Critical pressure) 42.47 bar
Rho_c (Critical density) 217 kg/m3
Tm (Melting point) -187.7 °C
Tb (Boiling point) -42.11 °C
Calculated results
Density nom. 4.0131 kg/m3
Molar mass 44.096 kg/kmol
Z-factor nom. 0.9649
Viscosity nom. 0.00845 cP
Sound velocity nom. 248.7 m/s
Thermal capacity nom. 1.742 kJ/(kg*K)
Heat conductivity nom. 0.018 W/(m K)
Vapor pressure nom. 10.815 bar_a
Pressure nom. 1.2 bar_g
Temperature nom. 30 °C
Reference values: Normal conditions (SI): Standard conditions (US):
Atmospheric pressure 1.0132 bar_a
Density normal 2.0122 kg/m3
Temperature 0 °C
Pressure 1.0132 bar_a
Atmospheric pressure 1.0132 bar_a
Density standard 1.9005 kg/m3
Temperature 59 °F
Pressure 14.696 psi_a
11. Print date: 29.04.2014 12:00 PM
Applicator®: 10.16.05 / 133
- 4 / 7 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-KHX
Timestamp: --- Review number: ---
Sales order number:
Installation sheet
Flowmeter / Accessories
Extended order code
Qty Item Description Extended order code
1 Flowmeter t-mass 65I 65I-20AB
1 Accessory Mounting boss - DK6MB DK6MB-B
Installation data :
Insertion depth X (scale value) 160.49 mm
Insertion tube length 235 mm
Pipe inner diameter 20°C 158.3 mm
Duct Installation Horizontal
Duct internal height
Duct internal width
Wall thickness 5 mm
C1 = Height process connection 60 mm
C2 = Height sensor connection 46 mm
C3 = Height ball valve 0 mm
C = Total height of connection 106 mm
A= Internal diameter or internal height (duct vertical installation) or internal width (duct horizontal installation)
B= Wall thickness
C= Height of connection
*The Enduser is responsible for the correct selection of the piping. Applicator does not calculate necessary pipe wall thickness according to application
data. Endress + Hauser takes no liability for the suitability of the pipe dimensions.
Attention for Flow! Device is used in non-ideal application conditions.
12. Print date: 29.04.2014 12:00 PM
Applicator®: 10.16.05 / 133
- 5 / 7 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-KHX
Timestamp: --- Review number: ---
Sales order number:
Tri-Size Sheet
General Parameters
Fluid Propane (Gas) Ref. Temperature 0 °C
State Gas Ref. Pressure 1.013 bar_a
Character Clean Atmospheric Pressure 1.0132 bar_a
Abrasivity Not abrasive Standard EN/DIN/ISO
Fluid Group (PED) Dangerous Fluid (Fluid group 1)
Sizing and Calculated Results
Next Smaller Size Current Size Next Bigger Size
Flow meter t-mass 65I t-mass 65I t-mass 65I
Flow Principle Thermal (t-mass) Thermal (t-mass) Thermal (t-mass)
Meter Size DN 100 DN 150 DN 200
Process connection* G 1 A ISO 228 / 1.4404 /316L G 1 A ISO 228 / 1.4404 /316L G 1 A ISO 228 / 1.4404 /316L
Minimum Flow 7.427 17.108 29.85 Nm3/h
Calibrated Flow 742.698 1 710.824 2 985.049 Nm3/h
Maximum Flow 1 485.4 3 421.65 5 970.1 Nm3/h
Pressure loss at req. Flow min. 6.42E-5 9.08E-6 2.49E-6 mbar
Pressure loss at req. Flow nom. 0.11 0.01 4.14E-3 mbar
Pressure loss at req. Flow max. 0.27 0.04 0.01 mbar
Velocity (meas. tube) at req. Flow min. 0.293 0.127 0.073 m/s
Velocity (meas. tube) at req. Flow nom. 12.72 5.52 3.164 m/s
Velocity (meas. tube) at req. Flow max. 20.03 8.697 4.985 m/s
Meas. error Mass at req. Flow min.*** 6.19 14.3 n.a. %
Meas. error Mass at req. Flow nom.*** 1.85 1.5 1.5 %
Meas. error Mass at req. Flow max.*** n.a. 1.5 1.5 %
Reynolds No. 629 646 414 858 314 070
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
13. Print date: 29.04.2014 12:00 PM
Applicator®: 10.16.05 / 133
- 6 / 7 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-KHX
Timestamp: --- Review number: ---
Sales order number:
Chart Sheet
Flowmeter : t-mass 65I
Flow Principle Thermal (t-mass)
Meter Size DN 150
Minimum Flow 17.108 Nm3/h
Calibrated Flow 1 710.824 Nm3/h
Maximum Flow 3 421.65 Nm3/h
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
14. Print date: 29.04.2014 12:00 PM
Applicator®: 10.16.05 / 133
- 7 / 7 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-KHX
Timestamp: --- Review number: ---
Sales order number:
Corrosion Information
General Parameters
Fluid Propane (Gas) Abrasivity Not abrasive
State Gas
Character Clean Flow Principle Thermal (t-mass)
Interpretation of Data, (M) Material:
A: resistant, 0.05 mm/y (0.002 inches/y)
B: insufficient resistant, 0.5 mm/y (0.02 inches/y)
C: not resistant, 1.3 mm/y (0.05 inches/y)
NR: not recommended
U: unknown
Interpretation of Data, (P) Plastics:
A: resistant, 15% vol. Swelling/y; 15% Loss of Tensile Strength/y
B: insufficient resistant, 30% vol. Swelling/y; 30% Loss of Tensile Strength/y
C: not resistant, 50% vol. Swelling/y; 60% Loss of Tensile Strength/y
NR: not recommended
U: unknown
Temperature
Material (Sensor) * minimum30°C nominal : 30°C maximum : 30°C
(M) CF3M - A 351 A A A
(P) EPDM U U U
(M) Alloy C22/2.4602 A A A
(P) Kalrez A A A
(P) PEEK C C C
(P) PVDF A A A
(M) Stainless steel 316L/316/1.4404 A A A
(P) Viton A A A
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
15. Print date: 29.04.2014 11:05 AM
Applicator®: 10.16.05 / 133
- 1 / 6 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-KK
Timestamp: --- Review number: ---
Sales order number:
Sizing Sheet
General Parameters
Fluid Propane (Gas) Ref. Temperature 0 °C
State Gas Ref. Pressure 1.013 bar_a
Character Clean Atmospheric Pressure 1.0132 bar_a
Abrasivity Not abrasive Standard EN/DIN/ISO
Fluid Group (PED) Dangerous Fluid (Fluid group 1)
Operating Conditions
minimum nominal maximum
Requested Flow 7 80 99 Nm3/h
Pressure 1.2 bar_g
Temperature 30 °C
Density 4.0131 kg/m3
Viscosity 0.00845 cP
Z-factor 0.9649
Sound Velocity 248.7 m/s
Pressure (min/max) 1.2 1.2 bar_g
Temp. (min/max) 30 30 °C
Flowmeter : t-mass 65F
Flow Principle Thermal (t-mass)
Meter Size DN 40
Minimum Flow 1.162 Nm3/h
Calibrated Flow 116.23 Nm3/h
Maximum Flow 232.46 Nm3/h
Material (sensor) * SS 1.4404 / 316L
Process connection* PN 40 EN 1092-1 B1 / 1.4404/316L Flange
PED category ** : Application is Cat. II
Extended order code
Qty Item Description Extended order code
1 Flowmeter t-mass 65F 65F40-AE**GP
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissible
pressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.
16. Print date: 29.04.2014 11:05 AM
Applicator®: 10.16.05 / 133
- 2 / 6 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-KK
Timestamp: --- Review number: ---
Sales order number:
Sizing Sheet
Sizing and Calculated Results
minimum nominal maximum
Requested Flow 7 80 99 Nm3/h
Pressure loss 4.21E-3 0.45 0.68 mbar
Velocity (meas. tube) 0.855 9.773 12.09 m/s
Measured error Mass*** 2.49 1.5 1.5 %
Reynolds No. 15 469 176 787 218 774
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
17. Print date: 29.04.2014 11:05 AM
Applicator®: 10.16.05 / 133
- 3 / 6 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-KK
Timestamp: --- Review number: ---
Sales order number:
Fluid properties sheet
Fluid
Fluid name Propane (Gas) State Gas
Chemical formula CH3-CH2-CH3 Calculation standard NEL
Fluid description
Medium character Clean
Fluid group (PED) Dangerous Fluid (Fluid group 1)
Fluid stability Stable
Gas mixture
Component
Fraction
1 Propane (Gas) 100 Mole% 100 Mass%
2 0 Mole% 0 Mass%
3 0 Mole% 0 Mass%
4 0 Mole% 0 Mass%
5 0 Mole% 0 Mass%
6 0 Mole% 0 Mass%
7 0 Mole% 0 Mass%
8 0 Mole% 0 Mass%
Basic fluid parameters
Tc (Critical temperature) 96.69 °C
Pc (Critical pressure) 42.47 bar
Rho_c (Critical density) 217 kg/m3
Tm (Melting point) -187.7 °C
Tb (Boiling point) -42.11 °C
Calculated results
Density nom. 4.0131 kg/m3
Molar mass 44.096 kg/kmol
Z-factor nom. 0.9649
Viscosity nom. 0.00845 cP
Sound velocity nom. 248.7 m/s
Thermal capacity nom. 1.742 kJ/(kg*K)
Heat conductivity nom. 0.018 W/(m K)
Vapor pressure nom. 10.815 bar_a
Pressure nom. 1.2 bar_g
Temperature nom. 30 °C
Reference values: Normal conditions (SI): Standard conditions (US):
Atmospheric pressure 1.0132 bar_a
Density normal 2.0122 kg/m3
Temperature 0 °C
Pressure 1.0132 bar_a
Atmospheric pressure 1.0132 bar_a
Density standard 1.9005 kg/m3
Temperature 59 °F
Pressure 14.696 psi_a
18. Print date: 29.04.2014 11:05 AM
Applicator®: 10.16.05 / 133
- 4 / 6 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-KK
Timestamp: --- Review number: ---
Sales order number:
Tri-Size Sheet
General Parameters
Fluid Propane (Gas) Ref. Temperature 0 °C
State Gas Ref. Pressure 1.013 bar_a
Character Clean Atmospheric Pressure 1.0132 bar_a
Abrasivity Not abrasive Standard EN/DIN/ISO
Fluid Group (PED) Dangerous Fluid (Fluid group 1)
Sizing and Calculated Results
Next Smaller Size Current Size Next Bigger Size
Flow meter t-mass 65F t-mass 65F t-mass 65F
Flow Principle Thermal (t-mass) Thermal (t-mass) Thermal (t-mass)
Meter Size DN 25 DN 40 DN 50
Process connection* PN 40 EN 1092-1
B1 / 1.4404/316L
PN 40 EN 1092-1
B1 / 1.4404/316L
PN 40 EN 1092-1
B1 / 1.4404/316L
Minimum Flow 0.419 1.162 1.906 Nm3/h
Calibrated Flow 41.885 116.23 190.575 Nm3/h
Maximum Flow 83.769 232.46 381.151 Nm3/h
Pressure loss at req. Flow min. 0.02 4.21E-3 1.46E-3 mbar
Pressure loss at req. Flow nom. 3.71 0.45 0.13 mbar
Pressure loss at req. Flow max. 5.7 0.68 0.21 mbar
Velocity (meas. tube) at req. Flow min. 2.102 0.855 0.513 m/s
Velocity (meas. tube) at req. Flow nom. 24.03 9.773 5.861 m/s
Velocity (meas. tube) at req. Flow max. 29.73 12.09 7.253 m/s
Meas. error Mass at req. Flow min.*** 1.5 2.49 4.08 %
Meas. error Mass at req. Flow nom.*** n.a. 1.5 1.5 %
Meas. error Mass at req. Flow max.*** n.a. 1.5 1.5 %
Reynolds No. 277 185 176 787 136 902
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
19. Print date: 29.04.2014 11:05 AM
Applicator®: 10.16.05 / 133
- 5 / 6 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-KK
Timestamp: --- Review number: ---
Sales order number:
Chart Sheet
Flowmeter : t-mass 65F
Flow Principle Thermal (t-mass)
Meter Size DN 40
Minimum Flow 1.162 Nm3/h
Calibrated Flow 116.23 Nm3/h
Maximum Flow 232.46 Nm3/h
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
20. Print date: 29.04.2014 11:05 AM
Applicator®: 10.16.05 / 133
- 6 / 6 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-KK
Timestamp: --- Review number: ---
Sales order number:
Corrosion Information
General Parameters
Fluid Propane (Gas) Abrasivity Not abrasive
State Gas
Character Clean Flow Principle Thermal (t-mass)
Interpretation of Data, (M) Material:
A: resistant, 0.05 mm/y (0.002 inches/y)
B: insufficient resistant, 0.5 mm/y (0.02 inches/y)
C: not resistant, 1.3 mm/y (0.05 inches/y)
NR: not recommended
U: unknown
Interpretation of Data, (P) Plastics:
A: resistant, 15% vol. Swelling/y; 15% Loss of Tensile Strength/y
B: insufficient resistant, 30% vol. Swelling/y; 30% Loss of Tensile Strength/y
C: not resistant, 50% vol. Swelling/y; 60% Loss of Tensile Strength/y
NR: not recommended
U: unknown
Temperature
Material (Sensor) * minimum30°C nominal : 30°C maximum : 30°C
(M) CF3M - A 351 A A A
(P) EPDM U U U
(M) Alloy C22/2.4602 A A A
(P) Kalrez A A A
(P) PEEK C C C
(P) PVDF A A A
(M) Stainless steel 316L/316/1.4404 A A A
(P) Viton A A A
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
21. Print date: 29.04.2014 11:16 AM
Applicator®: 10.16.05 / 133
- 1 / 6 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Boiler
Timestamp: --- Review number: ---
Sales order number:
Sizing Sheet
General Parameters
Fluid Propane (Gas) Ref. Temperature 0 °C
State Gas Ref. Pressure 1.013 bar_a
Character Clean Atmospheric Pressure 1.0132 bar_a
Abrasivity Not abrasive Standard EN/DIN/ISO
Fluid Group (PED) Dangerous Fluid (Fluid group 1)
Operating Conditions
minimum nominal maximum
Requested Flow 20 420 448 Nm3/h
Pressure 1.2 bar_g
Temperature 30 °C
Density 4.0131 kg/m3
Viscosity 0.00845 cP
Z-factor 0.9649
Sound Velocity 248.7 m/s
Pressure (min/max) 1.2 1.2 bar_g
Temp. (min/max) 30 30 °C
Flowmeter : t-mass 65F
Flow Principle Thermal (t-mass)
Meter Size DN 80
Minimum Flow 4.48 Nm3/h
Calibrated Flow 448.013 Nm3/h
Maximum Flow 896.026 Nm3/h
Material (sensor) * SS 1.4404 / 316L
Process connection* PN 40 EN 1092-1 B1 / 1.4404/316L Flange
PED category ** : Application is Cat. II
Extended order code
Qty Item Description Extended order code
1 Flowmeter t-mass 65F 65F80-AE**GP
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissible
pressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.
22. Print date: 29.04.2014 11:16 AM
Applicator®: 10.16.05 / 133
- 2 / 6 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Boiler
Timestamp: --- Review number: ---
Sales order number:
Sizing Sheet
Sizing and Calculated Results
minimum nominal maximum
Requested Flow 20 420 448 Nm3/h
Pressure loss 1.64E-3 0.52 0.6 mbar
Velocity (meas. tube) 0.594 12.46 13.3 m/s
Measured error Mass*** 3.36 1.5 1.5 %
Reynolds No. 21 784 457 463 487 961
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
23. Print date: 29.04.2014 11:16 AM
Applicator®: 10.16.05 / 133
- 3 / 6 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Boiler
Timestamp: --- Review number: ---
Sales order number:
Fluid properties sheet
Fluid
Fluid name Propane (Gas) State Gas
Chemical formula CH3-CH2-CH3 Calculation standard NEL
Fluid description
Medium character Clean
Fluid group (PED) Dangerous Fluid (Fluid group 1)
Fluid stability Stable
Gas mixture
Component
Fraction
1 Propane (Gas) 100 Mole% 100 Mass%
2 0 Mole% 0 Mass%
3 0 Mole% 0 Mass%
4 0 Mole% 0 Mass%
5 0 Mole% 0 Mass%
6 0 Mole% 0 Mass%
7 0 Mole% 0 Mass%
8 0 Mole% 0 Mass%
Basic fluid parameters
Tc (Critical temperature) 96.69 °C
Pc (Critical pressure) 42.47 bar
Rho_c (Critical density) 217 kg/m3
Tm (Melting point) -187.7 °C
Tb (Boiling point) -42.11 °C
Calculated results
Density nom. 4.0131 kg/m3
Molar mass 44.096 kg/kmol
Z-factor nom. 0.9649
Viscosity nom. 0.00845 cP
Sound velocity nom. 248.7 m/s
Thermal capacity nom. 1.742 kJ/(kg*K)
Heat conductivity nom. 0.018 W/(m K)
Vapor pressure nom. 10.815 bar_a
Pressure nom. 1.2 bar_g
Temperature nom. 30 °C
Reference values: Normal conditions (SI): Standard conditions (US):
Atmospheric pressure 1.0132 bar_a
Density normal 2.0122 kg/m3
Temperature 0 °C
Pressure 1.0132 bar_a
Atmospheric pressure 1.0132 bar_a
Density standard 1.9005 kg/m3
Temperature 59 °F
Pressure 14.696 psi_a
24. Print date: 29.04.2014 11:16 AM
Applicator®: 10.16.05 / 133
- 4 / 6 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Boiler
Timestamp: --- Review number: ---
Sales order number:
Tri-Size Sheet
General Parameters
Fluid Propane (Gas) Ref. Temperature 0 °C
State Gas Ref. Pressure 1.013 bar_a
Character Clean Atmospheric Pressure 1.0132 bar_a
Abrasivity Not abrasive Standard EN/DIN/ISO
Fluid Group (PED) Dangerous Fluid (Fluid group 1)
Sizing and Calculated Results
Next Smaller Size Current Size Next Bigger Size
Flow meter t-mass 65F t-mass 65F t-mass 65F
Flow Principle Thermal (t-mass) Thermal (t-mass) Thermal (t-mass)
Meter Size DN 50 DN 80 DN 100
Process connection* PN 40 EN 1092-1
B1 / 1.4404/316L
PN 40 EN 1092-1
B1 / 1.4404/316L
PN 16 EN 1092-1
B1 / 1.4404/316L
Minimum Flow 1.906 4.48 7.853 Nm3/h
Calibrated Flow 190.575 448.013 785.338 Nm3/h
Maximum Flow 381.151 896.026 1 570.68 Nm3/h
Pressure loss at req. Flow min. 9.29E-3 1.64E-3 6.5E-4 mbar
Pressure loss at req. Flow nom. 3.7 0.52 0.18 mbar
Pressure loss at req. Flow max. 4.21 0.6 0.21 mbar
Velocity (meas. tube) at req. Flow min. 1.465 0.594 0.369 m/s
Velocity (meas. tube) at req. Flow nom. 30.77 12.46 7.755 m/s
Velocity (meas. tube) at req. Flow max. 32.82 13.3 8.272 m/s
Meas. error Mass at req. Flow min.*** 1.5 3.36 5.89 %
Meas. error Mass at req. Flow nom.*** n.a. 1.5 1.5 %
Meas. error Mass at req. Flow max.*** n.a. 1.5 1.5 %
Reynolds No. 718 738 457 463 360 836
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
25. Print date: 29.04.2014 11:16 AM
Applicator®: 10.16.05 / 133
- 5 / 6 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Boiler
Timestamp: --- Review number: ---
Sales order number:
Chart Sheet
Flowmeter : t-mass 65F
Flow Principle Thermal (t-mass)
Meter Size DN 80
Minimum Flow 4.48 Nm3/h
Calibrated Flow 448.013 Nm3/h
Maximum Flow 896.026 Nm3/h
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
26. Print date: 29.04.2014 11:16 AM
Applicator®: 10.16.05 / 133
- 6 / 6 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Boiler
Timestamp: --- Review number: ---
Sales order number:
Corrosion Information
General Parameters
Fluid Propane (Gas) Abrasivity Not abrasive
State Gas
Character Clean Flow Principle Thermal (t-mass)
Interpretation of Data, (M) Material:
A: resistant, 0.05 mm/y (0.002 inches/y)
B: insufficient resistant, 0.5 mm/y (0.02 inches/y)
C: not resistant, 1.3 mm/y (0.05 inches/y)
NR: not recommended
U: unknown
Interpretation of Data, (P) Plastics:
A: resistant, 15% vol. Swelling/y; 15% Loss of Tensile Strength/y
B: insufficient resistant, 30% vol. Swelling/y; 30% Loss of Tensile Strength/y
C: not resistant, 50% vol. Swelling/y; 60% Loss of Tensile Strength/y
NR: not recommended
U: unknown
Temperature
Material (Sensor) * minimum30°C nominal : 30°C maximum : 30°C
(M) CF3M - A 351 A A A
(P) EPDM U U U
(M) Alloy C22/2.4602 A A A
(P) Kalrez A A A
(P) PEEK C C C
(P) PVDF A A A
(M) Stainless steel 316L/316/1.4404 A A A
(P) Viton A A A
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
27. Print date: 29.04.2014 11:09 AM
Applicator®: 10.16.05 / 133
- 1 / 6 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Canteen
Timestamp: --- Review number: ---
Sales order number:
Sizing Sheet
General Parameters
Fluid Propane (Gas) Ref. Temperature 0 °C
State Gas Ref. Pressure 1.013 bar_a
Character Clean Atmospheric Pressure 1.0132 bar_a
Abrasivity Not abrasive Standard EN/DIN/ISO
Fluid Group (PED) Dangerous Fluid (Fluid group 1)
Operating Conditions
minimum nominal maximum
Requested Flow 7 80 94 Nm3/h
Pressure 1.2 bar_g
Temperature 30 °C
Density 4.0131 kg/m3
Viscosity 0.00845 cP
Z-factor 0.9649
Sound Velocity 248.7 m/s
Pressure (min/max) 1.2 1.2 bar_g
Temp. (min/max) 30 30 °C
Flowmeter : t-mass 65F
Flow Principle Thermal (t-mass)
Meter Size DN 40
Minimum Flow 1.162 Nm3/h
Calibrated Flow 116.23 Nm3/h
Maximum Flow 232.46 Nm3/h
Material (sensor) * SS 1.4404 / 316L
Process connection* PN 40 EN 1092-1 B1 / 1.4404/316L Flange
PED category ** : Application is Cat. II
Extended order code
Qty Item Description Extended order code
1 Flowmeter t-mass 65F 65F40-AE**GP
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissible
pressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.
28. Print date: 29.04.2014 11:09 AM
Applicator®: 10.16.05 / 133
- 2 / 6 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Canteen
Timestamp: --- Review number: ---
Sales order number:
Sizing Sheet
Sizing and Calculated Results
minimum nominal maximum
Requested Flow 7 80 94 Nm3/h
Pressure loss 4.21E-3 0.45 0.62 mbar
Velocity (meas. tube) 0.855 9.773 11.48 m/s
Measured error Mass*** 2.49 1.5 1.5 %
Reynolds No. 15 469 176 787 207 725
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
29. Print date: 29.04.2014 11:09 AM
Applicator®: 10.16.05 / 133
- 3 / 6 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Canteen
Timestamp: --- Review number: ---
Sales order number:
Fluid properties sheet
Fluid
Fluid name Propane (Gas) State Gas
Chemical formula CH3-CH2-CH3 Calculation standard NEL
Fluid description
Medium character Clean
Fluid group (PED) Dangerous Fluid (Fluid group 1)
Fluid stability Stable
Gas mixture
Component
Fraction
1 Propane (Gas) 100 Mole% 100 Mass%
2 0 Mole% 0 Mass%
3 0 Mole% 0 Mass%
4 0 Mole% 0 Mass%
5 0 Mole% 0 Mass%
6 0 Mole% 0 Mass%
7 0 Mole% 0 Mass%
8 0 Mole% 0 Mass%
Basic fluid parameters
Tc (Critical temperature) 96.69 °C
Pc (Critical pressure) 42.47 bar
Rho_c (Critical density) 217 kg/m3
Tm (Melting point) -187.7 °C
Tb (Boiling point) -42.11 °C
Calculated results
Density nom. 4.0131 kg/m3
Molar mass 44.096 kg/kmol
Z-factor nom. 0.9649
Viscosity nom. 0.00845 cP
Sound velocity nom. 248.7 m/s
Thermal capacity nom. 1.742 kJ/(kg*K)
Heat conductivity nom. 0.018 W/(m K)
Vapor pressure nom. 10.815 bar_a
Pressure nom. 1.2 bar_g
Temperature nom. 30 °C
Reference values: Normal conditions (SI): Standard conditions (US):
Atmospheric pressure 1.0132 bar_a
Density normal 2.0122 kg/m3
Temperature 0 °C
Pressure 1.0132 bar_a
Atmospheric pressure 1.0132 bar_a
Density standard 1.9005 kg/m3
Temperature 59 °F
Pressure 14.696 psi_a
30. Print date: 29.04.2014 11:09 AM
Applicator®: 10.16.05 / 133
- 4 / 6 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Canteen
Timestamp: --- Review number: ---
Sales order number:
Tri-Size Sheet
General Parameters
Fluid Propane (Gas) Ref. Temperature 0 °C
State Gas Ref. Pressure 1.013 bar_a
Character Clean Atmospheric Pressure 1.0132 bar_a
Abrasivity Not abrasive Standard EN/DIN/ISO
Fluid Group (PED) Dangerous Fluid (Fluid group 1)
Sizing and Calculated Results
Next Smaller Size Current Size Next Bigger Size
Flow meter t-mass 65F t-mass 65F t-mass 65F
Flow Principle Thermal (t-mass) Thermal (t-mass) Thermal (t-mass)
Meter Size DN 25 DN 40 DN 50
Process connection* PN 40 EN 1092-1
B1 / 1.4404/316L
PN 40 EN 1092-1
B1 / 1.4404/316L
PN 40 EN 1092-1
B1 / 1.4404/316L
Minimum Flow 0.419 1.162 1.906 Nm3/h
Calibrated Flow 41.885 116.23 190.575 Nm3/h
Maximum Flow 83.769 232.46 381.151 Nm3/h
Pressure loss at req. Flow min. 0.02 4.21E-3 1.46E-3 mbar
Pressure loss at req. Flow nom. 3.71 0.45 0.13 mbar
Pressure loss at req. Flow max. 5.14 0.62 0.19 mbar
Velocity (meas. tube) at req. Flow min. 2.102 0.855 0.513 m/s
Velocity (meas. tube) at req. Flow nom. 24.03 9.773 5.861 m/s
Velocity (meas. tube) at req. Flow max. 28.23 11.48 6.887 m/s
Meas. error Mass at req. Flow min.*** 1.5 2.49 4.08 %
Meas. error Mass at req. Flow nom.*** n.a. 1.5 1.5 %
Meas. error Mass at req. Flow max.*** n.a. 1.5 1.5 %
Reynolds No. 277 185 176 787 136 902
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
31. Print date: 29.04.2014 11:09 AM
Applicator®: 10.16.05 / 133
- 5 / 6 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Canteen
Timestamp: --- Review number: ---
Sales order number:
Chart Sheet
Flowmeter : t-mass 65F
Flow Principle Thermal (t-mass)
Meter Size DN 40
Minimum Flow 1.162 Nm3/h
Calibrated Flow 116.23 Nm3/h
Maximum Flow 232.46 Nm3/h
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
32. Print date: 29.04.2014 11:09 AM
Applicator®: 10.16.05 / 133
- 6 / 6 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Canteen
Timestamp: --- Review number: ---
Sales order number:
Corrosion Information
General Parameters
Fluid Propane (Gas) Abrasivity Not abrasive
State Gas
Character Clean Flow Principle Thermal (t-mass)
Interpretation of Data, (M) Material:
A: resistant, 0.05 mm/y (0.002 inches/y)
B: insufficient resistant, 0.5 mm/y (0.02 inches/y)
C: not resistant, 1.3 mm/y (0.05 inches/y)
NR: not recommended
U: unknown
Interpretation of Data, (P) Plastics:
A: resistant, 15% vol. Swelling/y; 15% Loss of Tensile Strength/y
B: insufficient resistant, 30% vol. Swelling/y; 30% Loss of Tensile Strength/y
C: not resistant, 50% vol. Swelling/y; 60% Loss of Tensile Strength/y
NR: not recommended
U: unknown
Temperature
Material (Sensor) * minimum30°C nominal : 30°C maximum : 30°C
(M) CF3M - A 351 A A A
(P) EPDM U U U
(M) Alloy C22/2.4602 A A A
(P) Kalrez A A A
(P) PEEK C C C
(P) PVDF A A A
(M) Stainless steel 316L/316/1.4404 A A A
(P) Viton A A A
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
33. Print date: 29.04.2014 11:10 AM
Applicator®: 10.16.05 / 133
- 1 / 6 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Schaff
Timestamp: --- Review number: ---
Sales order number:
Sizing Sheet
General Parameters
Fluid Propane (Gas) Ref. Temperature 0 °C
State Gas Ref. Pressure 1.013 bar_a
Character Clean Atmospheric Pressure 1.0132 bar_a
Abrasivity Not abrasive Standard EN/DIN/ISO
Fluid Group (PED) Dangerous Fluid (Fluid group 1)
Operating Conditions
minimum nominal maximum
Requested Flow 7 80 94 Nm3/h
Pressure 1.2 bar_g
Temperature 30 °C
Density 4.0131 kg/m3
Viscosity 0.00845 cP
Z-factor 0.9649
Sound Velocity 248.7 m/s
Pressure (min/max) 1.2 1.2 bar_g
Temp. (min/max) 30 30 °C
Flowmeter : t-mass 65F
Flow Principle Thermal (t-mass)
Meter Size DN 40
Minimum Flow 1.162 Nm3/h
Calibrated Flow 116.23 Nm3/h
Maximum Flow 232.46 Nm3/h
Material (sensor) * SS 1.4404 / 316L
Process connection* PN 40 EN 1092-1 B1 / 1.4404/316L Flange
PED category ** : Application is Cat. II
Extended order code
Qty Item Description Extended order code
1 Flowmeter t-mass 65F 65F40-AE**GP
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissible
pressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.
34. Print date: 29.04.2014 11:10 AM
Applicator®: 10.16.05 / 133
- 2 / 6 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Schaff
Timestamp: --- Review number: ---
Sales order number:
Sizing Sheet
Sizing and Calculated Results
minimum nominal maximum
Requested Flow 7 80 94 Nm3/h
Pressure loss 4.21E-3 0.45 0.62 mbar
Velocity (meas. tube) 0.855 9.773 11.48 m/s
Measured error Mass*** 2.49 1.5 1.5 %
Reynolds No. 15 469 176 787 207 725
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
35. Print date: 29.04.2014 11:10 AM
Applicator®: 10.16.05 / 133
- 3 / 6 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Schaff
Timestamp: --- Review number: ---
Sales order number:
Fluid properties sheet
Fluid
Fluid name Propane (Gas) State Gas
Chemical formula CH3-CH2-CH3 Calculation standard NEL
Fluid description
Medium character Clean
Fluid group (PED) Dangerous Fluid (Fluid group 1)
Fluid stability Stable
Gas mixture
Component
Fraction
1 Propane (Gas) 100 Mole% 100 Mass%
2 0 Mole% 0 Mass%
3 0 Mole% 0 Mass%
4 0 Mole% 0 Mass%
5 0 Mole% 0 Mass%
6 0 Mole% 0 Mass%
7 0 Mole% 0 Mass%
8 0 Mole% 0 Mass%
Basic fluid parameters
Tc (Critical temperature) 96.69 °C
Pc (Critical pressure) 42.47 bar
Rho_c (Critical density) 217 kg/m3
Tm (Melting point) -187.7 °C
Tb (Boiling point) -42.11 °C
Calculated results
Density nom. 4.0131 kg/m3
Molar mass 44.096 kg/kmol
Z-factor nom. 0.9649
Viscosity nom. 0.00845 cP
Sound velocity nom. 248.7 m/s
Thermal capacity nom. 1.742 kJ/(kg*K)
Heat conductivity nom. 0.018 W/(m K)
Vapor pressure nom. 10.815 bar_a
Pressure nom. 1.2 bar_g
Temperature nom. 30 °C
Reference values: Normal conditions (SI): Standard conditions (US):
Atmospheric pressure 1.0132 bar_a
Density normal 2.0122 kg/m3
Temperature 0 °C
Pressure 1.0132 bar_a
Atmospheric pressure 1.0132 bar_a
Density standard 1.9005 kg/m3
Temperature 59 °F
Pressure 14.696 psi_a
36. Print date: 29.04.2014 11:10 AM
Applicator®: 10.16.05 / 133
- 4 / 6 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Schaff
Timestamp: --- Review number: ---
Sales order number:
Tri-Size Sheet
General Parameters
Fluid Propane (Gas) Ref. Temperature 0 °C
State Gas Ref. Pressure 1.013 bar_a
Character Clean Atmospheric Pressure 1.0132 bar_a
Abrasivity Not abrasive Standard EN/DIN/ISO
Fluid Group (PED) Dangerous Fluid (Fluid group 1)
Sizing and Calculated Results
Next Smaller Size Current Size Next Bigger Size
Flow meter t-mass 65F t-mass 65F t-mass 65F
Flow Principle Thermal (t-mass) Thermal (t-mass) Thermal (t-mass)
Meter Size DN 25 DN 40 DN 50
Process connection* PN 40 EN 1092-1
B1 / 1.4404/316L
PN 40 EN 1092-1
B1 / 1.4404/316L
PN 40 EN 1092-1
B1 / 1.4404/316L
Minimum Flow 0.419 1.162 1.906 Nm3/h
Calibrated Flow 41.885 116.23 190.575 Nm3/h
Maximum Flow 83.769 232.46 381.151 Nm3/h
Pressure loss at req. Flow min. 0.02 4.21E-3 1.46E-3 mbar
Pressure loss at req. Flow nom. 3.71 0.45 0.13 mbar
Pressure loss at req. Flow max. 5.14 0.62 0.19 mbar
Velocity (meas. tube) at req. Flow min. 2.102 0.855 0.513 m/s
Velocity (meas. tube) at req. Flow nom. 24.03 9.773 5.861 m/s
Velocity (meas. tube) at req. Flow max. 28.23 11.48 6.887 m/s
Meas. error Mass at req. Flow min.*** 1.5 2.49 4.08 %
Meas. error Mass at req. Flow nom.*** n.a. 1.5 1.5 %
Meas. error Mass at req. Flow max.*** n.a. 1.5 1.5 %
Reynolds No. 277 185 176 787 136 902
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
37. Print date: 29.04.2014 11:10 AM
Applicator®: 10.16.05 / 133
- 5 / 6 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Schaff
Timestamp: --- Review number: ---
Sales order number:
Chart Sheet
Flowmeter : t-mass 65F
Flow Principle Thermal (t-mass)
Meter Size DN 40
Minimum Flow 1.162 Nm3/h
Calibrated Flow 116.23 Nm3/h
Maximum Flow 232.46 Nm3/h
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
38. Print date: 29.04.2014 11:10 AM
Applicator®: 10.16.05 / 133
- 6 / 6 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Schaff
Timestamp: --- Review number: ---
Sales order number:
Corrosion Information
General Parameters
Fluid Propane (Gas) Abrasivity Not abrasive
State Gas
Character Clean Flow Principle Thermal (t-mass)
Interpretation of Data, (M) Material:
A: resistant, 0.05 mm/y (0.002 inches/y)
B: insufficient resistant, 0.5 mm/y (0.02 inches/y)
C: not resistant, 1.3 mm/y (0.05 inches/y)
NR: not recommended
U: unknown
Interpretation of Data, (P) Plastics:
A: resistant, 15% vol. Swelling/y; 15% Loss of Tensile Strength/y
B: insufficient resistant, 30% vol. Swelling/y; 30% Loss of Tensile Strength/y
C: not resistant, 50% vol. Swelling/y; 60% Loss of Tensile Strength/y
NR: not recommended
U: unknown
Temperature
Material (Sensor) * minimum30°C nominal : 30°C maximum : 30°C
(M) CF3M - A 351 A A A
(P) EPDM U U U
(M) Alloy C22/2.4602 A A A
(P) Kalrez A A A
(P) PEEK C C C
(P) PVDF A A A
(M) Stainless steel 316L/316/1.4404 A A A
(P) Viton A A A
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
39. Print date: 29.04.2014 08:56 AM
Applicator®: 10.16.05 / 133
- 1 / 7 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : NG-Main
Timestamp: --- Review number: ---
Sales order number:
Sizing Sheet
General Parameters
Fluid Natural Gas Ref. Temperature 0 °C
State Gas Ref. Pressure 1.013 bar_a
Character Clean Atmospheric Pressure 1.0132 bar_a
Abrasivity Not abrasive Standard EN/DIN/ISO
Fluid Group (PED) Dangerous Fluid (Fluid group 1)
Operating Conditions
minimum nominal maximum
Requested Flow 50 2 100 2 300 Nm3/h
Pressure 1.6 bar_g
Temperature 30 °C
Density 1.7929 kg/m3
Viscosity 0.01146 cP
Z-factor 0.9955
Sound Velocity 433.5 m/s
Pressure (min/max) 1.6 1.6 bar_g
Temp. (min/max) 30 30 °C
Flowmeter : t-mass 65I
Flow Principle Thermal (t-mass)
Meter Size DN 150
Minimum Flow 37.217 Nm3/h
Calibrated Flow 3 721.665 Nm3/h
Maximum Flow 7 443.33 Nm3/h
Material (sensor) * SS 1.4404 / 316L
Process connection* G 1 A ISO 228 / 1.4404 /316L Thread
PED category ** : Application meets PED (Art.3.3)
Extended order code
Qty Item Description Extended order code
1 Flowmeter t-mass 65I 65I-20AB
1 Accessory Mounting boss - DK6MB DK6MB-B
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissible
pressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.
40. Print date: 29.04.2014 08:56 AM
Applicator®: 10.16.05 / 133
- 2 / 7 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : NG-Main
Timestamp: --- Review number: ---
Sales order number:
Sizing Sheet
Sizing and Calculated Results
minimum nominal maximum
Requested Flow 50 2 100 2 300 Nm3/h
Pressure loss 2.33E-5 0.03 0.04 mbar
Velocity (meas. tube) 0.303 12.73 13.94 m/s
Measured error Mass*** 11.2 1.5 1.5 %
Reynolds No. 7 504 315 151 345 165
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
Attention for Flow! Device is used in non-ideal application conditions.
41. Print date: 29.04.2014 08:56 AM
Applicator®: 10.16.05 / 133
- 3 / 7 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : NG-Main
Timestamp: --- Review number: ---
Sales order number:
Fluid properties sheet
Fluid
Fluid name Natural Gas State Gas
Chemical formula NASA-Langley Calculation standard NEL
Fluid description
Medium character Clean
Fluid group (PED) Dangerous Fluid (Fluid group 1)
Fluid stability Stable
Gas mixture
Component
Fraction
1 Nitrogen (Gas) 2.8 Mole% 4.54 Mass%
2 Carbon dioxide (Gas) 0.21 Mole% 0.54 Mass%
3 Methane (Gas) 91.82 Mole% 85.5 Mass%
4 Ethane (Gas) 4.85 Mole% 8.53 Mass%
5 Propane (Gas) 0.26 Mole% 0.68 Mass%
6 n-Butane (Gas) 0.06 Mole% 0.21 Mass%
7 0 Mole% 0 Mass%
8 0 Mole% 0 Mass%
Basic fluid parameters
Tc (Critical temperature) -77.57 °C
Pc (Critical pressure) 46.1041 bar
Rho_c (Critical density) 168.8 kg/m3
Tm (Melting point) n.a. °C
Tb (Boiling point) n.a. °C
Calculated results
Density nom. 1.7929 kg/m3
Molar mass 17.214 kg/kmol
Z-factor nom. 0.9955
Viscosity nom. 0.01146 cP
Sound velocity nom. 433.5 m/s
Thermal capacity nom. 2.153 kJ/(kg*K)
Heat conductivity nom. 0.034 W/(m K)
Vapor pressure nom. bar_a
Pressure nom. 1.6 bar_g
Temperature nom. 30 °C
Reference values: Normal conditions (SI): Standard conditions (US):
Atmospheric pressure 1.0132 bar_a
Density normal 0.77 kg/m3
Temperature 0 °C
Pressure 1.0132 bar_a
Atmospheric pressure 1.0132 bar_a
Density standard 0.7296 kg/m3
Temperature 59 °F
Pressure 14.696 psi_a
42. Print date: 29.04.2014 08:56 AM
Applicator®: 10.16.05 / 133
- 4 / 7 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : NG-Main
Timestamp: --- Review number: ---
Sales order number:
Installation sheet
Flowmeter / Accessories
Extended order code
Qty Item Description Extended order code
1 Flowmeter t-mass 65I 65I-20AB
1 Accessory Mounting boss - DK6MB DK6MB-B
Installation data :
Insertion depth X (scale value) 160.49 mm
Insertion tube length 235 mm
Pipe inner diameter 20°C 158.3 mm
Duct Installation Horizontal
Duct internal height
Duct internal width
Wall thickness 5 mm
C1 = Height process connection 60 mm
C2 = Height sensor connection 46 mm
C3 = Height ball valve 0 mm
C = Total height of connection 106 mm
A= Internal diameter or internal height (duct vertical installation) or internal width (duct horizontal installation)
B= Wall thickness
C= Height of connection
*The Enduser is responsible for the correct selection of the piping. Applicator does not calculate necessary pipe wall thickness according to application
data. Endress + Hauser takes no liability for the suitability of the pipe dimensions.
Attention for Flow! Device is used in non-ideal application conditions.
43. Print date: 29.04.2014 08:56 AM
Applicator®: 10.16.05 / 133
- 5 / 7 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : NG-Main
Timestamp: --- Review number: ---
Sales order number:
Tri-Size Sheet
General Parameters
Fluid Natural Gas Ref. Temperature 0 °C
State Gas Ref. Pressure 1.013 bar_a
Character Clean Atmospheric Pressure 1.0132 bar_a
Abrasivity Not abrasive Standard EN/DIN/ISO
Fluid Group (PED) Dangerous Fluid (Fluid group 1)
Sizing and Calculated Results
Next Smaller Size Current Size Next Bigger Size
Flow meter t-mass 65I t-mass 65I t-mass 65I
Flow Principle Thermal (t-mass) Thermal (t-mass) Thermal (t-mass)
Meter Size DN 100 DN 150 DN 200
Process connection* G 1 A ISO 228 / 1.4404 /316L G 1 A ISO 228 / 1.4404 /316L G 1 A ISO 228 / 1.4404 /316L
Minimum Flow 16.156 37.217 64.936 Nm3/h
Calibrated Flow 1 615.638 3 721.665 6 493.57 Nm3/h
Maximum Flow 3 231.28 7 443.33 12 987.1 Nm3/h
Pressure loss at req. Flow min. 1.67E-4 2.33E-5 6.6E-6 mbar
Pressure loss at req. Flow nom. 0.26 0.03 9.66E-3 mbar
Pressure loss at req. Flow max. 0.31 0.04 0.01 mbar
Velocity (meas. tube) at req. Flow min. 0.698 0.303 0.174 m/s
Velocity (meas. tube) at req. Flow nom. 29.32 12.73 7.295 m/s
Velocity (meas. tube) at req. Flow max. 32.11 13.94 7.99 m/s
Meas. error Mass at req. Flow min.*** 4.85 11.2 n.a. %
Meas. error Mass at req. Flow nom.*** 3.6 1.5 1.5 %
Meas. error Mass at req. Flow max.*** 4.47 1.5 1.5 %
Reynolds No. 478 316 315 151 238 586
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
44. Print date: 29.04.2014 08:56 AM
Applicator®: 10.16.05 / 133
- 6 / 7 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : NG-Main
Timestamp: --- Review number: ---
Sales order number:
Chart Sheet
Flowmeter : t-mass 65I
Flow Principle Thermal (t-mass)
Meter Size DN 150
Minimum Flow 37.217 Nm3/h
Calibrated Flow 3 721.665 Nm3/h
Maximum Flow 7 443.33 Nm3/h
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
45. Print date: 29.04.2014 08:56 AM
Applicator®: 10.16.05 / 133
- 7 / 7 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : NG-Main
Timestamp: --- Review number: ---
Sales order number:
Corrosion Information
General Parameters
Fluid Natural Gas Abrasivity Not abrasive
State Gas
Character Clean Flow Principle Thermal (t-mass)
Interpretation of Data, (M) Material:
A: resistant, 0.05 mm/y (0.002 inches/y)
B: insufficient resistant, 0.5 mm/y (0.02 inches/y)
C: not resistant, 1.3 mm/y (0.05 inches/y)
NR: not recommended
U: unknown
Interpretation of Data, (P) Plastics:
A: resistant, 15% vol. Swelling/y; 15% Loss of Tensile Strength/y
B: insufficient resistant, 30% vol. Swelling/y; 30% Loss of Tensile Strength/y
C: not resistant, 50% vol. Swelling/y; 60% Loss of Tensile Strength/y
NR: not recommended
U: unknown
Temperature
Material (Sensor) * minimum30°C nominal : 30°C maximum : 30°C
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
46. Print date: 29.04.2014 09:18 AM
Applicator®: 10.16.05 / 133
- 1 / 6 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : NG-KHX
Timestamp: --- Review number: ---
Sales order number:
Sizing Sheet
General Parameters
Fluid Natural Gas Ref. Temperature 0 °C
State Gas Ref. Pressure 1.013 bar_a
Character Clean Atmospheric Pressure 1.0132 bar_a
Abrasivity Not abrasive Standard EN/DIN/ISO
Fluid Group (PED) Dangerous Fluid (Fluid group 1)
Operating Conditions
minimum nominal maximum
Requested Flow 84 1 050 1 150 Nm3/h
Pressure 1.6 bar_g
Temperature 30 °C
Density 1.7929 kg/m3
Viscosity 0.01146 cP
Z-factor 0.9955
Sound Velocity 433.5 m/s
Pressure (min/max) 1.6 1.6 bar_g
Temp. (min/max) 30 30 °C
Flowmeter : t-mass 65F
Flow Principle Thermal (t-mass)
Meter Size DN 100
Minimum Flow 17.084 Nm3/h
Calibrated Flow 1 708.397 Nm3/h
Maximum Flow 3 416.79 Nm3/h
Material (sensor) * SS 1.4404 / 316L
Process connection* PN 16 EN 1092-1 B1 / 1.4404/316L Flange
PED category ** : Application is Cat. II
Extended order code
Qty Item Description Extended order code
1 Flowmeter t-mass 65F 65F1H-AB**GP
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissible
pressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.
47. Print date: 29.04.2014 09:18 AM
Applicator®: 10.16.05 / 133
- 2 / 6 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : NG-KHX
Timestamp: --- Review number: ---
Sales order number:
Sizing Sheet
Sizing and Calculated Results
minimum nominal maximum
Requested Flow 84 1 050 1 150 Nm3/h
Pressure loss 3.6E-3 0.39 0.47 mbar
Velocity (meas. tube) 1.328 16.61 18.19 m/s
Measured error Mass*** 3.05 1.5 1.5 %
Reynolds No. 20 363 254 533 278 774
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
48. Print date: 29.04.2014 09:18 AM
Applicator®: 10.16.05 / 133
- 3 / 6 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : NG-KHX
Timestamp: --- Review number: ---
Sales order number:
Fluid properties sheet
Fluid
Fluid name Natural Gas State Gas
Chemical formula NASA-Langley Calculation standard NEL
Fluid description
Medium character Clean
Fluid group (PED) Dangerous Fluid (Fluid group 1)
Fluid stability Stable
Gas mixture
Component
Fraction
1 Nitrogen (Gas) 2.8 Mole% 4.54 Mass%
2 Carbon dioxide (Gas) 0.21 Mole% 0.54 Mass%
3 Methane (Gas) 91.82 Mole% 85.5 Mass%
4 Ethane (Gas) 4.85 Mole% 8.53 Mass%
5 Propane (Gas) 0.26 Mole% 0.68 Mass%
6 n-Butane (Gas) 0.06 Mole% 0.21 Mass%
7 0 Mole% 0 Mass%
8 0 Mole% 0 Mass%
Basic fluid parameters
Tc (Critical temperature) -77.57 °C
Pc (Critical pressure) 46.1041 bar
Rho_c (Critical density) 168.8 kg/m3
Tm (Melting point) n.a. °C
Tb (Boiling point) n.a. °C
Calculated results
Density nom. 1.7929 kg/m3
Molar mass 17.214 kg/kmol
Z-factor nom. 0.9955
Viscosity nom. 0.01146 cP
Sound velocity nom. 433.5 m/s
Thermal capacity nom. 2.153 kJ/(kg*K)
Heat conductivity nom. 0.034 W/(m K)
Vapor pressure nom. bar_a
Pressure nom. 1.6 bar_g
Temperature nom. 30 °C
Reference values: Normal conditions (SI): Standard conditions (US):
Atmospheric pressure 1.0132 bar_a
Density normal 0.77 kg/m3
Temperature 0 °C
Pressure 1.0132 bar_a
Atmospheric pressure 1.0132 bar_a
Density standard 0.7296 kg/m3
Temperature 59 °F
Pressure 14.696 psi_a
49. Print date: 29.04.2014 09:18 AM
Applicator®: 10.16.05 / 133
- 4 / 6 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : NG-KHX
Timestamp: --- Review number: ---
Sales order number:
Tri-Size Sheet
General Parameters
Fluid Natural Gas Ref. Temperature 0 °C
State Gas Ref. Pressure 1.013 bar_a
Character Clean Atmospheric Pressure 1.0132 bar_a
Abrasivity Not abrasive Standard EN/DIN/ISO
Fluid Group (PED) Dangerous Fluid (Fluid group 1)
Sizing and Calculated Results
Next Smaller Size Current Size Next Bigger Size
Flow meter t-mass 65F t-mass 65F
Flow Principle Thermal (t-mass) Thermal (t-mass)
Meter Size DN 80 DN 100
Process connection* PN 40 EN 1092-1
B1 / 1.4404/316L
PN 16 EN 1092-1
B1 / 1.4404/316L
Minimum Flow 9.746 17.084 Nm3/h
Calibrated Flow 974.591 1 708.397 Nm3/h
Maximum Flow 1 949.18 3 416.79 Nm3/h
Pressure loss at req. Flow min. 9.13E-3 3.6E-3 mbar
Pressure loss at req. Flow nom. 1.09 0.39 mbar
Pressure loss at req. Flow max. 1.31 0.47 mbar
Velocity (meas. tube) at req. Flow min. 2.135 1.328 m/s
Velocity (meas. tube) at req. Flow nom. 26.69 16.61 m/s
Velocity (meas. tube) at req. Flow max. 29.23 18.19 m/s
Meas. error Mass at req. Flow min.*** 1.74 3.05 %
Meas. error Mass at req. Flow nom.*** 2.04 1.5 %
Meas. error Mass at req. Flow max.*** 2.76 1.5 %
Reynolds No. 322 693 254 533
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
50. Print date: 29.04.2014 09:18 AM
Applicator®: 10.16.05 / 133
- 5 / 6 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : NG-KHX
Timestamp: --- Review number: ---
Sales order number:
Chart Sheet
Flowmeter : t-mass 65F
Flow Principle Thermal (t-mass)
Meter Size DN 100
Minimum Flow 17.084 Nm3/h
Calibrated Flow 1 708.397 Nm3/h
Maximum Flow 3 416.79 Nm3/h
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
51. Print date: 29.04.2014 09:18 AM
Applicator®: 10.16.05 / 133
- 6 / 6 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : NG-KHX
Timestamp: --- Review number: ---
Sales order number:
Corrosion Information
General Parameters
Fluid Natural Gas Abrasivity Not abrasive
State Gas
Character Clean Flow Principle Thermal (t-mass)
Interpretation of Data, (M) Material:
A: resistant, 0.05 mm/y (0.002 inches/y)
B: insufficient resistant, 0.5 mm/y (0.02 inches/y)
C: not resistant, 1.3 mm/y (0.05 inches/y)
NR: not recommended
U: unknown
Interpretation of Data, (P) Plastics:
A: resistant, 15% vol. Swelling/y; 15% Loss of Tensile Strength/y
B: insufficient resistant, 30% vol. Swelling/y; 30% Loss of Tensile Strength/y
C: not resistant, 50% vol. Swelling/y; 60% Loss of Tensile Strength/y
NR: not recommended
U: unknown
Temperature
Material (Sensor) * minimum30°C nominal : 30°C maximum : 30°C
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
52. Print date: 29.04.2014 09:22 AM
Applicator®: 10.16.05 / 133
- 1 / 6 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : NG-Gas Genset
Timestamp: --- Review number: ---
Sales order number:
Sizing Sheet
General Parameters
Fluid Natural Gas Ref. Temperature 0 °C
State Gas Ref. Pressure 1.013 bar_a
Character Clean Atmospheric Pressure 1.0132 bar_a
Abrasivity Not abrasive Standard EN/DIN/ISO
Fluid Group (PED) Dangerous Fluid (Fluid group 1)
Operating Conditions
minimum nominal maximum
Requested Flow 50 650 700 Nm3/h
Pressure 1.6 bar_g
Temperature 30 °C
Density 1.7929 kg/m3
Viscosity 0.01146 cP
Z-factor 0.9955
Sound Velocity 433.5 m/s
Pressure (min/max) 1.6 1.6 bar_g
Temp. (min/max) 30 30 °C
Flowmeter : t-mass 65F
Flow Principle Thermal (t-mass)
Meter Size DN 80
Minimum Flow 9.746 Nm3/h
Calibrated Flow 974.591 Nm3/h
Maximum Flow 1 949.18 Nm3/h
Material (sensor) * SS 1.4404 / 316L
Process connection* PN 40 EN 1092-1 B1 / 1.4404/316L Flange
PED category ** : Application is Cat. II
Extended order code
Qty Item Description Extended order code
1 Flowmeter t-mass 65F 65F80-AE**GP
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissible
pressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.
53. Print date: 29.04.2014 09:22 AM
Applicator®: 10.16.05 / 133
- 2 / 6 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : NG-Gas Genset
Timestamp: --- Review number: ---
Sales order number:
Sizing Sheet
Sizing and Calculated Results
minimum nominal maximum
Requested Flow 50 650 700 Nm3/h
Pressure loss 3.68E-3 0.42 0.49 mbar
Velocity (meas. tube) 1.271 16.52 17.79 m/s
Measured error Mass*** 2.92 1.5 1.5 %
Reynolds No. 15 366 199 763 215 129
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
54. Print date: 29.04.2014 09:22 AM
Applicator®: 10.16.05 / 133
- 3 / 6 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : NG-Gas Genset
Timestamp: --- Review number: ---
Sales order number:
Fluid properties sheet
Fluid
Fluid name Natural Gas State Gas
Chemical formula NASA-Langley Calculation standard NEL
Fluid description
Medium character Clean
Fluid group (PED) Dangerous Fluid (Fluid group 1)
Fluid stability Stable
Gas mixture
Component
Fraction
1 Nitrogen (Gas) 2.8 Mole% 4.54 Mass%
2 Carbon dioxide (Gas) 0.21 Mole% 0.54 Mass%
3 Methane (Gas) 91.82 Mole% 85.5 Mass%
4 Ethane (Gas) 4.85 Mole% 8.53 Mass%
5 Propane (Gas) 0.26 Mole% 0.68 Mass%
6 n-Butane (Gas) 0.06 Mole% 0.21 Mass%
7 0 Mole% 0 Mass%
8 0 Mole% 0 Mass%
Basic fluid parameters
Tc (Critical temperature) -77.57 °C
Pc (Critical pressure) 46.1041 bar
Rho_c (Critical density) 168.8 kg/m3
Tm (Melting point) n.a. °C
Tb (Boiling point) n.a. °C
Calculated results
Density nom. 1.7929 kg/m3
Molar mass 17.214 kg/kmol
Z-factor nom. 0.9955
Viscosity nom. 0.01146 cP
Sound velocity nom. 433.5 m/s
Thermal capacity nom. 2.153 kJ/(kg*K)
Heat conductivity nom. 0.034 W/(m K)
Vapor pressure nom. bar_a
Pressure nom. 1.6 bar_g
Temperature nom. 30 °C
Reference values: Normal conditions (SI): Standard conditions (US):
Atmospheric pressure 1.0132 bar_a
Density normal 0.77 kg/m3
Temperature 0 °C
Pressure 1.0132 bar_a
Atmospheric pressure 1.0132 bar_a
Density standard 0.7296 kg/m3
Temperature 59 °F
Pressure 14.696 psi_a
55. Print date: 29.04.2014 09:22 AM
Applicator®: 10.16.05 / 133
- 4 / 6 -
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : NG-Gas Genset
Timestamp: --- Review number: ---
Sales order number:
Tri-Size Sheet
General Parameters
Fluid Natural Gas Ref. Temperature 0 °C
State Gas Ref. Pressure 1.013 bar_a
Character Clean Atmospheric Pressure 1.0132 bar_a
Abrasivity Not abrasive Standard EN/DIN/ISO
Fluid Group (PED) Dangerous Fluid (Fluid group 1)
Sizing and Calculated Results
Next Smaller Size Current Size Next Bigger Size
Flow meter t-mass 65F t-mass 65F t-mass 65F
Flow Principle Thermal (t-mass) Thermal (t-mass) Thermal (t-mass)
Meter Size DN 50 DN 80 DN 100
Process connection* PN 40 EN 1092-1
B1 / 1.4404/316L
PN 40 EN 1092-1
B1 / 1.4404/316L
PN 16 EN 1092-1
B1 / 1.4404/316L
Minimum Flow 4.146 9.746 17.084 Nm3/h
Calibrated Flow 414.571 974.591 1 708.397 Nm3/h
Maximum Flow 829.142 1 949.18 3 416.79 Nm3/h
Pressure loss at req. Flow min. 0.02 3.68E-3 1.45E-3 mbar
Pressure loss at req. Flow nom. 2.93 0.42 0.15 mbar
Pressure loss at req. Flow max. 3.39 0.49 0.18 mbar
Velocity (meas. tube) at req. Flow min. 3.137 1.271 0.791 m/s
Velocity (meas. tube) at req. Flow nom. 40.79 16.52 10.28 m/s
Velocity (meas. tube) at req. Flow max. 43.92 17.79 11.07 m/s
Meas. error Mass at req. Flow min.*** 1.5 2.92 5.13 %
Meas. error Mass at req. Flow nom.*** n.a. 1.5 1.5 %
Meas. error Mass at req. Flow max.*** n.a. 1.5 1.5 %
Reynolds No. 313 855 199 763 157 568
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.