Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Main
Timestamp: --- Review number: ---
Sales order number:
Sizing Sheet
General Parameters
Fluid Propane (Gas) Ref. Temperature 0 °C
State Gas Ref. Pressure 1.013 bar_a
Character Clean Atmospheric Pressure 1.0132 bar_a
Abrasivity Not abrasive Standard EN/DIN/ISO
Fluid Group (PED) Dangerous Fluid (Fluid group 1)
Operating Conditions
minimum nominal maximum
Requested Flow 18 780 1 229 Nm3/h
Pressure 1.2 bar_g
Temperature 30 °C
Density 4.0131 kg/m3
Viscosity 0.00845 cP
Z-factor 0.9649
Sound Velocity 248.7 m/s
Pressure (min/max) 1.2 1.2 bar_g
Temp. (min/max) 30 30 °C
Flowmeter : t-mass 65I
Flow Principle Thermal (t-mass)
Meter Size DN 150
Minimum Flow 17.108   Nm3/h
Calibrated Flow 1 710.824   Nm3/h
Maximum Flow 3 421.65   Nm3/h
Material (sensor) * SS 1.4404 / 316L
Process connection* G 1 A ISO 228 / 1.4404 /316L Thread
PED category ** : Application meets PED (Art.3.3)
  Extended order code
Qty Item Description Extended order code
1 Flowmeter t-mass 65I 65I-20AB
1 Accessory Mounting boss - DK6MB DK6MB-B
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissible
pressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.
Print date: 29.04.2014 11:58 AM
Applicator®: 10.16.05 / 133
- 2 / 7 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Main
Timestamp: --- Review number: ---
Sales order number:
Sizing Sheet
Sizing and Calculated Results
minimum nominal maximum
Requested Flow 18 780 1 229 Nm3/h
Pressure loss 9.08E-6 0.01 0.04 mbar
Velocity (meas. tube) 0.127 5.52 8.697 m/s
Measured error Mass*** 14.3 1.5 1.5 %
Reynolds No. 9 574 414 858 653 668
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
Attention for Flow! Device is used in non-ideal application conditions.
Print date: 29.04.2014 11:58 AM
Applicator®: 10.16.05 / 133
- 3 / 7 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Main
Timestamp: --- Review number: ---
Sales order number:
Fluid properties sheet
Fluid
Fluid name Propane (Gas) State Gas
Chemical formula CH3-CH2-CH3 Calculation standard NEL
Fluid description
Medium character Clean
Fluid group (PED) Dangerous Fluid (Fluid group 1)
Fluid stability Stable
Gas mixture
Component
Fraction
1    Propane (Gas) 100   Mole% 100   Mass%
2    0   Mole% 0   Mass%
3    0   Mole% 0   Mass%
4    0   Mole% 0   Mass%
5    0   Mole% 0   Mass%
6    0   Mole% 0   Mass%
7    0   Mole% 0   Mass%
8    0   Mole% 0   Mass%
Basic fluid parameters
Tc (Critical temperature) 96.69   °C
Pc (Critical pressure) 42.47   bar
Rho_c (Critical density) 217   kg/m3
Tm (Melting point) -187.7   °C
Tb (Boiling point) -42.11   °C
Calculated results
Density nom. 4.0131   kg/m3
Molar mass 44.096   kg/kmol
Z-factor nom. 0.9649
Viscosity nom. 0.00845   cP
Sound velocity nom. 248.7   m/s
Thermal capacity nom. 1.742   kJ/(kg*K)
Heat conductivity nom. 0.018   W/(m K)
Vapor pressure nom. 10.815   bar_a
Pressure nom. 1.2   bar_g
Temperature nom. 30   °C
 
Reference values:   Normal conditions (SI): Standard conditions (US):
Atmospheric pressure 1.0132   bar_a
Density normal 2.0122   kg/m3
Temperature 0   °C
Pressure 1.0132   bar_a
Atmospheric pressure 1.0132   bar_a
Density standard 1.9005   kg/m3
Temperature 59   °F
Pressure 14.696   psi_a
Print date: 29.04.2014 11:58 AM
Applicator®: 10.16.05 / 133
- 4 / 7 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Main
Timestamp: --- Review number: ---
Sales order number:
Installation sheet
Flowmeter / Accessories
  Extended order code
Qty Item Description Extended order code
1 Flowmeter t-mass 65I 65I-20AB
1 Accessory Mounting boss - DK6MB DK6MB-B
Installation data :
Insertion depth X (scale value) 160.49   mm
Insertion tube length 235   mm
Pipe inner diameter 20°C 158.3   mm
Duct Installation Horizontal
Duct internal height  
Duct internal width  
Wall thickness 5   mm
C1 = Height process connection 60   mm
C2 = Height sensor connection 46   mm
C3 = Height ball valve 0   mm
C = Total height of connection 106   mm
A= Internal diameter or internal height (duct vertical installation) or internal width (duct horizontal installation)
B= Wall thickness
C= Height of connection
*The Enduser is responsible for the correct selection of the piping. Applicator does not calculate necessary pipe wall thickness according to application
data. Endress + Hauser takes no liability for the suitability of the pipe dimensions.
Attention for Flow! Device is used in non-ideal application conditions.
Print date: 29.04.2014 11:58 AM
Applicator®: 10.16.05 / 133
- 5 / 7 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Main
Timestamp: --- Review number: ---
Sales order number:
Tri-Size Sheet
General Parameters
Fluid Propane (Gas) Ref. Temperature 0 °C
State Gas Ref. Pressure 1.013 bar_a
Character Clean Atmospheric Pressure 1.0132 bar_a
Abrasivity Not abrasive Standard EN/DIN/ISO
Fluid Group (PED) Dangerous Fluid (Fluid group 1)
Sizing and Calculated Results
Next Smaller Size Current Size Next Bigger Size
Flow meter t-mass 65I t-mass 65I t-mass 65I
Flow Principle Thermal (t-mass) Thermal (t-mass) Thermal (t-mass)
Meter Size DN 100 DN 150 DN 200
Process connection* G 1 A ISO 228 / 1.4404 /316L G 1 A ISO 228 / 1.4404 /316L G 1 A ISO 228 / 1.4404 /316L
Minimum Flow 7.427 17.108 29.85 Nm3/h
Calibrated Flow 742.698 1 710.824 2 985.049 Nm3/h
Maximum Flow 1 485.4 3 421.65 5 970.1 Nm3/h
Pressure loss at req. Flow min. 6.42E-5 9.08E-6 2.49E-6 mbar
Pressure loss at req. Flow nom. 0.11 0.01 4.14E-3 mbar
Pressure loss at req. Flow max. 0.27 0.04 0.01 mbar
Velocity (meas. tube) at req. Flow min. 0.293 0.127 0.073 m/s
Velocity (meas. tube) at req. Flow nom. 12.72 5.52 3.164 m/s
Velocity (meas. tube) at req. Flow max. 20.03 8.697 4.985 m/s
Meas. error Mass at req. Flow min.*** 6.19 14.3 n.a. %
Meas. error Mass at req. Flow nom.*** 1.85 1.5 1.5 %
Meas. error Mass at req. Flow max.*** n.a. 1.5 1.5 %
Reynolds No. 629 646 414 858 314 070
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
Print date: 29.04.2014 11:58 AM
Applicator®: 10.16.05 / 133
- 6 / 7 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Main
Timestamp: --- Review number: ---
Sales order number:
Chart Sheet
Flowmeter : t-mass 65I
Flow Principle Thermal (t-mass)
Meter Size DN 150
Minimum Flow 17.108   Nm3/h
Calibrated Flow 1 710.824   Nm3/h
Maximum Flow 3 421.65   Nm3/h
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
Print date: 29.04.2014 11:58 AM
Applicator®: 10.16.05 / 133
- 7 / 7 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Main
Timestamp: --- Review number: ---
Sales order number:
Corrosion Information
General Parameters
Fluid Propane (Gas) Abrasivity Not abrasive
State Gas
Character Clean Flow Principle Thermal (t-mass)
Interpretation of Data, (M) Material:
A: resistant, 0.05 mm/y (0.002 inches/y)
B: insufficient resistant, 0.5 mm/y (0.02 inches/y)
C: not resistant, 1.3 mm/y (0.05 inches/y)
NR: not recommended
U: unknown
Interpretation of Data, (P) Plastics:
A: resistant, 15% vol. Swelling/y; 15% Loss of Tensile Strength/y
B: insufficient resistant, 30% vol. Swelling/y; 30% Loss of Tensile Strength/y
C: not resistant, 50% vol. Swelling/y; 60% Loss of Tensile Strength/y
NR: not recommended
U: unknown
Temperature
Material (Sensor) * minimum30°C nominal : 30°C maximum : 30°C
(M) CF3M - A 351 A A A
(P) EPDM U U U
(M) Alloy C22/2.4602 A A A
(P) Kalrez A A A
(P) PEEK C C C
(P) PVDF A A A
(M) Stainless steel 316L/316/1.4404 A A A
(P) Viton A A A
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
Print date: 29.04.2014 12:00 PM
Applicator®: 10.16.05 / 133
- 1 / 7 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-KHX
Timestamp: --- Review number: ---
Sales order number:
Sizing Sheet
General Parameters
Fluid Propane (Gas) Ref. Temperature 0 °C
State Gas Ref. Pressure 1.013 bar_a
Character Clean Atmospheric Pressure 1.0132 bar_a
Abrasivity Not abrasive Standard EN/DIN/ISO
Fluid Group (PED) Dangerous Fluid (Fluid group 1)
Operating Conditions
minimum nominal maximum
Requested Flow 18 780 1 229 Nm3/h
Pressure 1.2 bar_g
Temperature 30 °C
Density 4.0131 kg/m3
Viscosity 0.00845 cP
Z-factor 0.9649
Sound Velocity 248.7 m/s
Pressure (min/max) 1.2 1.2 bar_g
Temp. (min/max) 30 30 °C
Flowmeter : t-mass 65I
Flow Principle Thermal (t-mass)
Meter Size DN 150
Minimum Flow 17.108   Nm3/h
Calibrated Flow 1 710.824   Nm3/h
Maximum Flow 3 421.65   Nm3/h
Material (sensor) * SS 1.4404 / 316L
Process connection* G 1 A ISO 228 / 1.4404 /316L Thread
PED category ** : Application meets PED (Art.3.3)
  Extended order code
Qty Item Description Extended order code
1 Flowmeter t-mass 65I 65I-20AB
1 Accessory Mounting boss - DK6MB DK6MB-B
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissible
pressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.
Print date: 29.04.2014 12:00 PM
Applicator®: 10.16.05 / 133
- 2 / 7 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-KHX
Timestamp: --- Review number: ---
Sales order number:
Sizing Sheet
Sizing and Calculated Results
minimum nominal maximum
Requested Flow 18 780 1 229 Nm3/h
Pressure loss 9.08E-6 0.01 0.04 mbar
Velocity (meas. tube) 0.127 5.52 8.697 m/s
Measured error Mass*** 14.3 1.5 1.5 %
Reynolds No. 9 574 414 858 653 668
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
Attention for Flow! Device is used in non-ideal application conditions.
Print date: 29.04.2014 12:00 PM
Applicator®: 10.16.05 / 133
- 3 / 7 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-KHX
Timestamp: --- Review number: ---
Sales order number:
Fluid properties sheet
Fluid
Fluid name Propane (Gas) State Gas
Chemical formula CH3-CH2-CH3 Calculation standard NEL
Fluid description
Medium character Clean
Fluid group (PED) Dangerous Fluid (Fluid group 1)
Fluid stability Stable
Gas mixture
Component
Fraction
1    Propane (Gas) 100   Mole% 100   Mass%
2    0   Mole% 0   Mass%
3    0   Mole% 0   Mass%
4    0   Mole% 0   Mass%
5    0   Mole% 0   Mass%
6    0   Mole% 0   Mass%
7    0   Mole% 0   Mass%
8    0   Mole% 0   Mass%
Basic fluid parameters
Tc (Critical temperature) 96.69   °C
Pc (Critical pressure) 42.47   bar
Rho_c (Critical density) 217   kg/m3
Tm (Melting point) -187.7   °C
Tb (Boiling point) -42.11   °C
Calculated results
Density nom. 4.0131   kg/m3
Molar mass 44.096   kg/kmol
Z-factor nom. 0.9649
Viscosity nom. 0.00845   cP
Sound velocity nom. 248.7   m/s
Thermal capacity nom. 1.742   kJ/(kg*K)
Heat conductivity nom. 0.018   W/(m K)
Vapor pressure nom. 10.815   bar_a
Pressure nom. 1.2   bar_g
Temperature nom. 30   °C
 
Reference values:   Normal conditions (SI): Standard conditions (US):
Atmospheric pressure 1.0132   bar_a
Density normal 2.0122   kg/m3
Temperature 0   °C
Pressure 1.0132   bar_a
Atmospheric pressure 1.0132   bar_a
Density standard 1.9005   kg/m3
Temperature 59   °F
Pressure 14.696   psi_a
Print date: 29.04.2014 12:00 PM
Applicator®: 10.16.05 / 133
- 4 / 7 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-KHX
Timestamp: --- Review number: ---
Sales order number:
Installation sheet
Flowmeter / Accessories
  Extended order code
Qty Item Description Extended order code
1 Flowmeter t-mass 65I 65I-20AB
1 Accessory Mounting boss - DK6MB DK6MB-B
Installation data :
Insertion depth X (scale value) 160.49   mm
Insertion tube length 235   mm
Pipe inner diameter 20°C 158.3   mm
Duct Installation Horizontal
Duct internal height  
Duct internal width  
Wall thickness 5   mm
C1 = Height process connection 60   mm
C2 = Height sensor connection 46   mm
C3 = Height ball valve 0   mm
C = Total height of connection 106   mm
A= Internal diameter or internal height (duct vertical installation) or internal width (duct horizontal installation)
B= Wall thickness
C= Height of connection
*The Enduser is responsible for the correct selection of the piping. Applicator does not calculate necessary pipe wall thickness according to application
data. Endress + Hauser takes no liability for the suitability of the pipe dimensions.
Attention for Flow! Device is used in non-ideal application conditions.
Print date: 29.04.2014 12:00 PM
Applicator®: 10.16.05 / 133
- 5 / 7 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-KHX
Timestamp: --- Review number: ---
Sales order number:
Tri-Size Sheet
General Parameters
Fluid Propane (Gas) Ref. Temperature 0 °C
State Gas Ref. Pressure 1.013 bar_a
Character Clean Atmospheric Pressure 1.0132 bar_a
Abrasivity Not abrasive Standard EN/DIN/ISO
Fluid Group (PED) Dangerous Fluid (Fluid group 1)
Sizing and Calculated Results
Next Smaller Size Current Size Next Bigger Size
Flow meter t-mass 65I t-mass 65I t-mass 65I
Flow Principle Thermal (t-mass) Thermal (t-mass) Thermal (t-mass)
Meter Size DN 100 DN 150 DN 200
Process connection* G 1 A ISO 228 / 1.4404 /316L G 1 A ISO 228 / 1.4404 /316L G 1 A ISO 228 / 1.4404 /316L
Minimum Flow 7.427 17.108 29.85 Nm3/h
Calibrated Flow 742.698 1 710.824 2 985.049 Nm3/h
Maximum Flow 1 485.4 3 421.65 5 970.1 Nm3/h
Pressure loss at req. Flow min. 6.42E-5 9.08E-6 2.49E-6 mbar
Pressure loss at req. Flow nom. 0.11 0.01 4.14E-3 mbar
Pressure loss at req. Flow max. 0.27 0.04 0.01 mbar
Velocity (meas. tube) at req. Flow min. 0.293 0.127 0.073 m/s
Velocity (meas. tube) at req. Flow nom. 12.72 5.52 3.164 m/s
Velocity (meas. tube) at req. Flow max. 20.03 8.697 4.985 m/s
Meas. error Mass at req. Flow min.*** 6.19 14.3 n.a. %
Meas. error Mass at req. Flow nom.*** 1.85 1.5 1.5 %
Meas. error Mass at req. Flow max.*** n.a. 1.5 1.5 %
Reynolds No. 629 646 414 858 314 070
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
Print date: 29.04.2014 12:00 PM
Applicator®: 10.16.05 / 133
- 6 / 7 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-KHX
Timestamp: --- Review number: ---
Sales order number:
Chart Sheet
Flowmeter : t-mass 65I
Flow Principle Thermal (t-mass)
Meter Size DN 150
Minimum Flow 17.108   Nm3/h
Calibrated Flow 1 710.824   Nm3/h
Maximum Flow 3 421.65   Nm3/h
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
Print date: 29.04.2014 12:00 PM
Applicator®: 10.16.05 / 133
- 7 / 7 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-KHX
Timestamp: --- Review number: ---
Sales order number:
Corrosion Information
General Parameters
Fluid Propane (Gas) Abrasivity Not abrasive
State Gas
Character Clean Flow Principle Thermal (t-mass)
Interpretation of Data, (M) Material:
A: resistant, 0.05 mm/y (0.002 inches/y)
B: insufficient resistant, 0.5 mm/y (0.02 inches/y)
C: not resistant, 1.3 mm/y (0.05 inches/y)
NR: not recommended
U: unknown
Interpretation of Data, (P) Plastics:
A: resistant, 15% vol. Swelling/y; 15% Loss of Tensile Strength/y
B: insufficient resistant, 30% vol. Swelling/y; 30% Loss of Tensile Strength/y
C: not resistant, 50% vol. Swelling/y; 60% Loss of Tensile Strength/y
NR: not recommended
U: unknown
Temperature
Material (Sensor) * minimum30°C nominal : 30°C maximum : 30°C
(M) CF3M - A 351 A A A
(P) EPDM U U U
(M) Alloy C22/2.4602 A A A
(P) Kalrez A A A
(P) PEEK C C C
(P) PVDF A A A
(M) Stainless steel 316L/316/1.4404 A A A
(P) Viton A A A
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
Print date: 29.04.2014 11:05 AM
Applicator®: 10.16.05 / 133
- 1 / 6 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-KK
Timestamp: --- Review number: ---
Sales order number:
Sizing Sheet
General Parameters
Fluid Propane (Gas) Ref. Temperature 0 °C
State Gas Ref. Pressure 1.013 bar_a
Character Clean Atmospheric Pressure 1.0132 bar_a
Abrasivity Not abrasive Standard EN/DIN/ISO
Fluid Group (PED) Dangerous Fluid (Fluid group 1)
Operating Conditions
minimum nominal maximum
Requested Flow 7 80 99 Nm3/h
Pressure 1.2 bar_g
Temperature 30 °C
Density 4.0131 kg/m3
Viscosity 0.00845 cP
Z-factor 0.9649
Sound Velocity 248.7 m/s
Pressure (min/max) 1.2 1.2 bar_g
Temp. (min/max) 30 30 °C
Flowmeter : t-mass 65F
Flow Principle Thermal (t-mass)
Meter Size DN 40
Minimum Flow 1.162   Nm3/h
Calibrated Flow 116.23   Nm3/h
Maximum Flow 232.46   Nm3/h
Material (sensor) * SS 1.4404 / 316L
Process connection* PN 40 EN 1092-1 B1 / 1.4404/316L Flange
PED category ** : Application is Cat. II
  Extended order code
Qty Item Description Extended order code
1 Flowmeter t-mass 65F 65F40-AE**GP
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissible
pressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.
Print date: 29.04.2014 11:05 AM
Applicator®: 10.16.05 / 133
- 2 / 6 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-KK
Timestamp: --- Review number: ---
Sales order number:
Sizing Sheet
Sizing and Calculated Results
minimum nominal maximum
Requested Flow 7 80 99 Nm3/h
Pressure loss 4.21E-3 0.45 0.68 mbar
Velocity (meas. tube) 0.855 9.773 12.09 m/s
Measured error Mass*** 2.49 1.5 1.5 %
Reynolds No. 15 469 176 787 218 774
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
Print date: 29.04.2014 11:05 AM
Applicator®: 10.16.05 / 133
- 3 / 6 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-KK
Timestamp: --- Review number: ---
Sales order number:
Fluid properties sheet
Fluid
Fluid name Propane (Gas) State Gas
Chemical formula CH3-CH2-CH3 Calculation standard NEL
Fluid description
Medium character Clean
Fluid group (PED) Dangerous Fluid (Fluid group 1)
Fluid stability Stable
Gas mixture
Component
Fraction
1    Propane (Gas) 100   Mole% 100   Mass%
2    0   Mole% 0   Mass%
3    0   Mole% 0   Mass%
4    0   Mole% 0   Mass%
5    0   Mole% 0   Mass%
6    0   Mole% 0   Mass%
7    0   Mole% 0   Mass%
8    0   Mole% 0   Mass%
Basic fluid parameters
Tc (Critical temperature) 96.69   °C
Pc (Critical pressure) 42.47   bar
Rho_c (Critical density) 217   kg/m3
Tm (Melting point) -187.7   °C
Tb (Boiling point) -42.11   °C
Calculated results
Density nom. 4.0131   kg/m3
Molar mass 44.096   kg/kmol
Z-factor nom. 0.9649
Viscosity nom. 0.00845   cP
Sound velocity nom. 248.7   m/s
Thermal capacity nom. 1.742   kJ/(kg*K)
Heat conductivity nom. 0.018   W/(m K)
Vapor pressure nom. 10.815   bar_a
Pressure nom. 1.2   bar_g
Temperature nom. 30   °C
 
Reference values:   Normal conditions (SI): Standard conditions (US):
Atmospheric pressure 1.0132   bar_a
Density normal 2.0122   kg/m3
Temperature 0   °C
Pressure 1.0132   bar_a
Atmospheric pressure 1.0132   bar_a
Density standard 1.9005   kg/m3
Temperature 59   °F
Pressure 14.696   psi_a
Print date: 29.04.2014 11:05 AM
Applicator®: 10.16.05 / 133
- 4 / 6 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-KK
Timestamp: --- Review number: ---
Sales order number:
Tri-Size Sheet
General Parameters
Fluid Propane (Gas) Ref. Temperature 0 °C
State Gas Ref. Pressure 1.013 bar_a
Character Clean Atmospheric Pressure 1.0132 bar_a
Abrasivity Not abrasive Standard EN/DIN/ISO
Fluid Group (PED) Dangerous Fluid (Fluid group 1)
Sizing and Calculated Results
Next Smaller Size Current Size Next Bigger Size
Flow meter t-mass 65F t-mass 65F t-mass 65F
Flow Principle Thermal (t-mass) Thermal (t-mass) Thermal (t-mass)
Meter Size DN 25 DN 40 DN 50
Process connection* PN 40 EN 1092-1
B1 / 1.4404/316L
PN 40 EN 1092-1
B1 / 1.4404/316L
PN 40 EN 1092-1
B1 / 1.4404/316L
Minimum Flow 0.419 1.162 1.906 Nm3/h
Calibrated Flow 41.885 116.23 190.575 Nm3/h
Maximum Flow 83.769 232.46 381.151 Nm3/h
Pressure loss at req. Flow min. 0.02 4.21E-3 1.46E-3 mbar
Pressure loss at req. Flow nom. 3.71 0.45 0.13 mbar
Pressure loss at req. Flow max. 5.7 0.68 0.21 mbar
Velocity (meas. tube) at req. Flow min. 2.102 0.855 0.513 m/s
Velocity (meas. tube) at req. Flow nom. 24.03 9.773 5.861 m/s
Velocity (meas. tube) at req. Flow max. 29.73 12.09 7.253 m/s
Meas. error Mass at req. Flow min.*** 1.5 2.49 4.08 %
Meas. error Mass at req. Flow nom.*** n.a. 1.5 1.5 %
Meas. error Mass at req. Flow max.*** n.a. 1.5 1.5 %
Reynolds No. 277 185 176 787 136 902
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
Print date: 29.04.2014 11:05 AM
Applicator®: 10.16.05 / 133
- 5 / 6 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-KK
Timestamp: --- Review number: ---
Sales order number:
Chart Sheet
Flowmeter : t-mass 65F
Flow Principle Thermal (t-mass)
Meter Size DN 40
Minimum Flow 1.162   Nm3/h
Calibrated Flow 116.23   Nm3/h
Maximum Flow 232.46   Nm3/h
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
Print date: 29.04.2014 11:05 AM
Applicator®: 10.16.05 / 133
- 6 / 6 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-KK
Timestamp: --- Review number: ---
Sales order number:
Corrosion Information
General Parameters
Fluid Propane (Gas) Abrasivity Not abrasive
State Gas
Character Clean Flow Principle Thermal (t-mass)
Interpretation of Data, (M) Material:
A: resistant, 0.05 mm/y (0.002 inches/y)
B: insufficient resistant, 0.5 mm/y (0.02 inches/y)
C: not resistant, 1.3 mm/y (0.05 inches/y)
NR: not recommended
U: unknown
Interpretation of Data, (P) Plastics:
A: resistant, 15% vol. Swelling/y; 15% Loss of Tensile Strength/y
B: insufficient resistant, 30% vol. Swelling/y; 30% Loss of Tensile Strength/y
C: not resistant, 50% vol. Swelling/y; 60% Loss of Tensile Strength/y
NR: not recommended
U: unknown
Temperature
Material (Sensor) * minimum30°C nominal : 30°C maximum : 30°C
(M) CF3M - A 351 A A A
(P) EPDM U U U
(M) Alloy C22/2.4602 A A A
(P) Kalrez A A A
(P) PEEK C C C
(P) PVDF A A A
(M) Stainless steel 316L/316/1.4404 A A A
(P) Viton A A A
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
Print date: 29.04.2014 11:16 AM
Applicator®: 10.16.05 / 133
- 1 / 6 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Boiler
Timestamp: --- Review number: ---
Sales order number:
Sizing Sheet
General Parameters
Fluid Propane (Gas) Ref. Temperature 0 °C
State Gas Ref. Pressure 1.013 bar_a
Character Clean Atmospheric Pressure 1.0132 bar_a
Abrasivity Not abrasive Standard EN/DIN/ISO
Fluid Group (PED) Dangerous Fluid (Fluid group 1)
Operating Conditions
minimum nominal maximum
Requested Flow 20 420 448 Nm3/h
Pressure 1.2 bar_g
Temperature 30 °C
Density 4.0131 kg/m3
Viscosity 0.00845 cP
Z-factor 0.9649
Sound Velocity 248.7 m/s
Pressure (min/max) 1.2 1.2 bar_g
Temp. (min/max) 30 30 °C
Flowmeter : t-mass 65F
Flow Principle Thermal (t-mass)
Meter Size DN 80
Minimum Flow 4.48   Nm3/h
Calibrated Flow 448.013   Nm3/h
Maximum Flow 896.026   Nm3/h
Material (sensor) * SS 1.4404 / 316L
Process connection* PN 40 EN 1092-1 B1 / 1.4404/316L Flange
PED category ** : Application is Cat. II
  Extended order code
Qty Item Description Extended order code
1 Flowmeter t-mass 65F 65F80-AE**GP
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissible
pressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.
Print date: 29.04.2014 11:16 AM
Applicator®: 10.16.05 / 133
- 2 / 6 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Boiler
Timestamp: --- Review number: ---
Sales order number:
Sizing Sheet
Sizing and Calculated Results
minimum nominal maximum
Requested Flow 20 420 448 Nm3/h
Pressure loss 1.64E-3 0.52 0.6 mbar
Velocity (meas. tube) 0.594 12.46 13.3 m/s
Measured error Mass*** 3.36 1.5 1.5 %
Reynolds No. 21 784 457 463 487 961
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
Print date: 29.04.2014 11:16 AM
Applicator®: 10.16.05 / 133
- 3 / 6 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Boiler
Timestamp: --- Review number: ---
Sales order number:
Fluid properties sheet
Fluid
Fluid name Propane (Gas) State Gas
Chemical formula CH3-CH2-CH3 Calculation standard NEL
Fluid description
Medium character Clean
Fluid group (PED) Dangerous Fluid (Fluid group 1)
Fluid stability Stable
Gas mixture
Component
Fraction
1    Propane (Gas) 100   Mole% 100   Mass%
2    0   Mole% 0   Mass%
3    0   Mole% 0   Mass%
4    0   Mole% 0   Mass%
5    0   Mole% 0   Mass%
6    0   Mole% 0   Mass%
7    0   Mole% 0   Mass%
8    0   Mole% 0   Mass%
Basic fluid parameters
Tc (Critical temperature) 96.69   °C
Pc (Critical pressure) 42.47   bar
Rho_c (Critical density) 217   kg/m3
Tm (Melting point) -187.7   °C
Tb (Boiling point) -42.11   °C
Calculated results
Density nom. 4.0131   kg/m3
Molar mass 44.096   kg/kmol
Z-factor nom. 0.9649
Viscosity nom. 0.00845   cP
Sound velocity nom. 248.7   m/s
Thermal capacity nom. 1.742   kJ/(kg*K)
Heat conductivity nom. 0.018   W/(m K)
Vapor pressure nom. 10.815   bar_a
Pressure nom. 1.2   bar_g
Temperature nom. 30   °C
 
Reference values:   Normal conditions (SI): Standard conditions (US):
Atmospheric pressure 1.0132   bar_a
Density normal 2.0122   kg/m3
Temperature 0   °C
Pressure 1.0132   bar_a
Atmospheric pressure 1.0132   bar_a
Density standard 1.9005   kg/m3
Temperature 59   °F
Pressure 14.696   psi_a
Print date: 29.04.2014 11:16 AM
Applicator®: 10.16.05 / 133
- 4 / 6 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Boiler
Timestamp: --- Review number: ---
Sales order number:
Tri-Size Sheet
General Parameters
Fluid Propane (Gas) Ref. Temperature 0 °C
State Gas Ref. Pressure 1.013 bar_a
Character Clean Atmospheric Pressure 1.0132 bar_a
Abrasivity Not abrasive Standard EN/DIN/ISO
Fluid Group (PED) Dangerous Fluid (Fluid group 1)
Sizing and Calculated Results
Next Smaller Size Current Size Next Bigger Size
Flow meter t-mass 65F t-mass 65F t-mass 65F
Flow Principle Thermal (t-mass) Thermal (t-mass) Thermal (t-mass)
Meter Size DN 50 DN 80 DN 100
Process connection* PN 40 EN 1092-1
B1 / 1.4404/316L
PN 40 EN 1092-1
B1 / 1.4404/316L
PN 16 EN 1092-1
B1 / 1.4404/316L
Minimum Flow 1.906 4.48 7.853 Nm3/h
Calibrated Flow 190.575 448.013 785.338 Nm3/h
Maximum Flow 381.151 896.026 1 570.68 Nm3/h
Pressure loss at req. Flow min. 9.29E-3 1.64E-3 6.5E-4 mbar
Pressure loss at req. Flow nom. 3.7 0.52 0.18 mbar
Pressure loss at req. Flow max. 4.21 0.6 0.21 mbar
Velocity (meas. tube) at req. Flow min. 1.465 0.594 0.369 m/s
Velocity (meas. tube) at req. Flow nom. 30.77 12.46 7.755 m/s
Velocity (meas. tube) at req. Flow max. 32.82 13.3 8.272 m/s
Meas. error Mass at req. Flow min.*** 1.5 3.36 5.89 %
Meas. error Mass at req. Flow nom.*** n.a. 1.5 1.5 %
Meas. error Mass at req. Flow max.*** n.a. 1.5 1.5 %
Reynolds No. 718 738 457 463 360 836
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
Print date: 29.04.2014 11:16 AM
Applicator®: 10.16.05 / 133
- 5 / 6 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Boiler
Timestamp: --- Review number: ---
Sales order number:
Chart Sheet
Flowmeter : t-mass 65F
Flow Principle Thermal (t-mass)
Meter Size DN 80
Minimum Flow 4.48   Nm3/h
Calibrated Flow 448.013   Nm3/h
Maximum Flow 896.026   Nm3/h
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
Print date: 29.04.2014 11:16 AM
Applicator®: 10.16.05 / 133
- 6 / 6 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Boiler
Timestamp: --- Review number: ---
Sales order number:
Corrosion Information
General Parameters
Fluid Propane (Gas) Abrasivity Not abrasive
State Gas
Character Clean Flow Principle Thermal (t-mass)
Interpretation of Data, (M) Material:
A: resistant, 0.05 mm/y (0.002 inches/y)
B: insufficient resistant, 0.5 mm/y (0.02 inches/y)
C: not resistant, 1.3 mm/y (0.05 inches/y)
NR: not recommended
U: unknown
Interpretation of Data, (P) Plastics:
A: resistant, 15% vol. Swelling/y; 15% Loss of Tensile Strength/y
B: insufficient resistant, 30% vol. Swelling/y; 30% Loss of Tensile Strength/y
C: not resistant, 50% vol. Swelling/y; 60% Loss of Tensile Strength/y
NR: not recommended
U: unknown
Temperature
Material (Sensor) * minimum30°C nominal : 30°C maximum : 30°C
(M) CF3M - A 351 A A A
(P) EPDM U U U
(M) Alloy C22/2.4602 A A A
(P) Kalrez A A A
(P) PEEK C C C
(P) PVDF A A A
(M) Stainless steel 316L/316/1.4404 A A A
(P) Viton A A A
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
Print date: 29.04.2014 11:09 AM
Applicator®: 10.16.05 / 133
- 1 / 6 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Canteen
Timestamp: --- Review number: ---
Sales order number:
Sizing Sheet
General Parameters
Fluid Propane (Gas) Ref. Temperature 0 °C
State Gas Ref. Pressure 1.013 bar_a
Character Clean Atmospheric Pressure 1.0132 bar_a
Abrasivity Not abrasive Standard EN/DIN/ISO
Fluid Group (PED) Dangerous Fluid (Fluid group 1)
Operating Conditions
minimum nominal maximum
Requested Flow 7 80 94 Nm3/h
Pressure 1.2 bar_g
Temperature 30 °C
Density 4.0131 kg/m3
Viscosity 0.00845 cP
Z-factor 0.9649
Sound Velocity 248.7 m/s
Pressure (min/max) 1.2 1.2 bar_g
Temp. (min/max) 30 30 °C
Flowmeter : t-mass 65F
Flow Principle Thermal (t-mass)
Meter Size DN 40
Minimum Flow 1.162   Nm3/h
Calibrated Flow 116.23   Nm3/h
Maximum Flow 232.46   Nm3/h
Material (sensor) * SS 1.4404 / 316L
Process connection* PN 40 EN 1092-1 B1 / 1.4404/316L Flange
PED category ** : Application is Cat. II
  Extended order code
Qty Item Description Extended order code
1 Flowmeter t-mass 65F 65F40-AE**GP
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissible
pressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.
Print date: 29.04.2014 11:09 AM
Applicator®: 10.16.05 / 133
- 2 / 6 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Canteen
Timestamp: --- Review number: ---
Sales order number:
Sizing Sheet
Sizing and Calculated Results
minimum nominal maximum
Requested Flow 7 80 94 Nm3/h
Pressure loss 4.21E-3 0.45 0.62 mbar
Velocity (meas. tube) 0.855 9.773 11.48 m/s
Measured error Mass*** 2.49 1.5 1.5 %
Reynolds No. 15 469 176 787 207 725
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
Print date: 29.04.2014 11:09 AM
Applicator®: 10.16.05 / 133
- 3 / 6 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Canteen
Timestamp: --- Review number: ---
Sales order number:
Fluid properties sheet
Fluid
Fluid name Propane (Gas) State Gas
Chemical formula CH3-CH2-CH3 Calculation standard NEL
Fluid description
Medium character Clean
Fluid group (PED) Dangerous Fluid (Fluid group 1)
Fluid stability Stable
Gas mixture
Component
Fraction
1    Propane (Gas) 100   Mole% 100   Mass%
2    0   Mole% 0   Mass%
3    0   Mole% 0   Mass%
4    0   Mole% 0   Mass%
5    0   Mole% 0   Mass%
6    0   Mole% 0   Mass%
7    0   Mole% 0   Mass%
8    0   Mole% 0   Mass%
Basic fluid parameters
Tc (Critical temperature) 96.69   °C
Pc (Critical pressure) 42.47   bar
Rho_c (Critical density) 217   kg/m3
Tm (Melting point) -187.7   °C
Tb (Boiling point) -42.11   °C
Calculated results
Density nom. 4.0131   kg/m3
Molar mass 44.096   kg/kmol
Z-factor nom. 0.9649
Viscosity nom. 0.00845   cP
Sound velocity nom. 248.7   m/s
Thermal capacity nom. 1.742   kJ/(kg*K)
Heat conductivity nom. 0.018   W/(m K)
Vapor pressure nom. 10.815   bar_a
Pressure nom. 1.2   bar_g
Temperature nom. 30   °C
 
Reference values:   Normal conditions (SI): Standard conditions (US):
Atmospheric pressure 1.0132   bar_a
Density normal 2.0122   kg/m3
Temperature 0   °C
Pressure 1.0132   bar_a
Atmospheric pressure 1.0132   bar_a
Density standard 1.9005   kg/m3
Temperature 59   °F
Pressure 14.696   psi_a
Print date: 29.04.2014 11:09 AM
Applicator®: 10.16.05 / 133
- 4 / 6 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Canteen
Timestamp: --- Review number: ---
Sales order number:
Tri-Size Sheet
General Parameters
Fluid Propane (Gas) Ref. Temperature 0 °C
State Gas Ref. Pressure 1.013 bar_a
Character Clean Atmospheric Pressure 1.0132 bar_a
Abrasivity Not abrasive Standard EN/DIN/ISO
Fluid Group (PED) Dangerous Fluid (Fluid group 1)
Sizing and Calculated Results
Next Smaller Size Current Size Next Bigger Size
Flow meter t-mass 65F t-mass 65F t-mass 65F
Flow Principle Thermal (t-mass) Thermal (t-mass) Thermal (t-mass)
Meter Size DN 25 DN 40 DN 50
Process connection* PN 40 EN 1092-1
B1 / 1.4404/316L
PN 40 EN 1092-1
B1 / 1.4404/316L
PN 40 EN 1092-1
B1 / 1.4404/316L
Minimum Flow 0.419 1.162 1.906 Nm3/h
Calibrated Flow 41.885 116.23 190.575 Nm3/h
Maximum Flow 83.769 232.46 381.151 Nm3/h
Pressure loss at req. Flow min. 0.02 4.21E-3 1.46E-3 mbar
Pressure loss at req. Flow nom. 3.71 0.45 0.13 mbar
Pressure loss at req. Flow max. 5.14 0.62 0.19 mbar
Velocity (meas. tube) at req. Flow min. 2.102 0.855 0.513 m/s
Velocity (meas. tube) at req. Flow nom. 24.03 9.773 5.861 m/s
Velocity (meas. tube) at req. Flow max. 28.23 11.48 6.887 m/s
Meas. error Mass at req. Flow min.*** 1.5 2.49 4.08 %
Meas. error Mass at req. Flow nom.*** n.a. 1.5 1.5 %
Meas. error Mass at req. Flow max.*** n.a. 1.5 1.5 %
Reynolds No. 277 185 176 787 136 902
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
Print date: 29.04.2014 11:09 AM
Applicator®: 10.16.05 / 133
- 5 / 6 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Canteen
Timestamp: --- Review number: ---
Sales order number:
Chart Sheet
Flowmeter : t-mass 65F
Flow Principle Thermal (t-mass)
Meter Size DN 40
Minimum Flow 1.162   Nm3/h
Calibrated Flow 116.23   Nm3/h
Maximum Flow 232.46   Nm3/h
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
Print date: 29.04.2014 11:09 AM
Applicator®: 10.16.05 / 133
- 6 / 6 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Canteen
Timestamp: --- Review number: ---
Sales order number:
Corrosion Information
General Parameters
Fluid Propane (Gas) Abrasivity Not abrasive
State Gas
Character Clean Flow Principle Thermal (t-mass)
Interpretation of Data, (M) Material:
A: resistant, 0.05 mm/y (0.002 inches/y)
B: insufficient resistant, 0.5 mm/y (0.02 inches/y)
C: not resistant, 1.3 mm/y (0.05 inches/y)
NR: not recommended
U: unknown
Interpretation of Data, (P) Plastics:
A: resistant, 15% vol. Swelling/y; 15% Loss of Tensile Strength/y
B: insufficient resistant, 30% vol. Swelling/y; 30% Loss of Tensile Strength/y
C: not resistant, 50% vol. Swelling/y; 60% Loss of Tensile Strength/y
NR: not recommended
U: unknown
Temperature
Material (Sensor) * minimum30°C nominal : 30°C maximum : 30°C
(M) CF3M - A 351 A A A
(P) EPDM U U U
(M) Alloy C22/2.4602 A A A
(P) Kalrez A A A
(P) PEEK C C C
(P) PVDF A A A
(M) Stainless steel 316L/316/1.4404 A A A
(P) Viton A A A
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
Print date: 29.04.2014 11:10 AM
Applicator®: 10.16.05 / 133
- 1 / 6 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Schaff
Timestamp: --- Review number: ---
Sales order number:
Sizing Sheet
General Parameters
Fluid Propane (Gas) Ref. Temperature 0 °C
State Gas Ref. Pressure 1.013 bar_a
Character Clean Atmospheric Pressure 1.0132 bar_a
Abrasivity Not abrasive Standard EN/DIN/ISO
Fluid Group (PED) Dangerous Fluid (Fluid group 1)
Operating Conditions
minimum nominal maximum
Requested Flow 7 80 94 Nm3/h
Pressure 1.2 bar_g
Temperature 30 °C
Density 4.0131 kg/m3
Viscosity 0.00845 cP
Z-factor 0.9649
Sound Velocity 248.7 m/s
Pressure (min/max) 1.2 1.2 bar_g
Temp. (min/max) 30 30 °C
Flowmeter : t-mass 65F
Flow Principle Thermal (t-mass)
Meter Size DN 40
Minimum Flow 1.162   Nm3/h
Calibrated Flow 116.23   Nm3/h
Maximum Flow 232.46   Nm3/h
Material (sensor) * SS 1.4404 / 316L
Process connection* PN 40 EN 1092-1 B1 / 1.4404/316L Flange
PED category ** : Application is Cat. II
  Extended order code
Qty Item Description Extended order code
1 Flowmeter t-mass 65F 65F40-AE**GP
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissible
pressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.
Print date: 29.04.2014 11:10 AM
Applicator®: 10.16.05 / 133
- 2 / 6 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Schaff
Timestamp: --- Review number: ---
Sales order number:
Sizing Sheet
Sizing and Calculated Results
minimum nominal maximum
Requested Flow 7 80 94 Nm3/h
Pressure loss 4.21E-3 0.45 0.62 mbar
Velocity (meas. tube) 0.855 9.773 11.48 m/s
Measured error Mass*** 2.49 1.5 1.5 %
Reynolds No. 15 469 176 787 207 725
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
Print date: 29.04.2014 11:10 AM
Applicator®: 10.16.05 / 133
- 3 / 6 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Schaff
Timestamp: --- Review number: ---
Sales order number:
Fluid properties sheet
Fluid
Fluid name Propane (Gas) State Gas
Chemical formula CH3-CH2-CH3 Calculation standard NEL
Fluid description
Medium character Clean
Fluid group (PED) Dangerous Fluid (Fluid group 1)
Fluid stability Stable
Gas mixture
Component
Fraction
1    Propane (Gas) 100   Mole% 100   Mass%
2    0   Mole% 0   Mass%
3    0   Mole% 0   Mass%
4    0   Mole% 0   Mass%
5    0   Mole% 0   Mass%
6    0   Mole% 0   Mass%
7    0   Mole% 0   Mass%
8    0   Mole% 0   Mass%
Basic fluid parameters
Tc (Critical temperature) 96.69   °C
Pc (Critical pressure) 42.47   bar
Rho_c (Critical density) 217   kg/m3
Tm (Melting point) -187.7   °C
Tb (Boiling point) -42.11   °C
Calculated results
Density nom. 4.0131   kg/m3
Molar mass 44.096   kg/kmol
Z-factor nom. 0.9649
Viscosity nom. 0.00845   cP
Sound velocity nom. 248.7   m/s
Thermal capacity nom. 1.742   kJ/(kg*K)
Heat conductivity nom. 0.018   W/(m K)
Vapor pressure nom. 10.815   bar_a
Pressure nom. 1.2   bar_g
Temperature nom. 30   °C
 
Reference values:   Normal conditions (SI): Standard conditions (US):
Atmospheric pressure 1.0132   bar_a
Density normal 2.0122   kg/m3
Temperature 0   °C
Pressure 1.0132   bar_a
Atmospheric pressure 1.0132   bar_a
Density standard 1.9005   kg/m3
Temperature 59   °F
Pressure 14.696   psi_a
Print date: 29.04.2014 11:10 AM
Applicator®: 10.16.05 / 133
- 4 / 6 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Schaff
Timestamp: --- Review number: ---
Sales order number:
Tri-Size Sheet
General Parameters
Fluid Propane (Gas) Ref. Temperature 0 °C
State Gas Ref. Pressure 1.013 bar_a
Character Clean Atmospheric Pressure 1.0132 bar_a
Abrasivity Not abrasive Standard EN/DIN/ISO
Fluid Group (PED) Dangerous Fluid (Fluid group 1)
Sizing and Calculated Results
Next Smaller Size Current Size Next Bigger Size
Flow meter t-mass 65F t-mass 65F t-mass 65F
Flow Principle Thermal (t-mass) Thermal (t-mass) Thermal (t-mass)
Meter Size DN 25 DN 40 DN 50
Process connection* PN 40 EN 1092-1
B1 / 1.4404/316L
PN 40 EN 1092-1
B1 / 1.4404/316L
PN 40 EN 1092-1
B1 / 1.4404/316L
Minimum Flow 0.419 1.162 1.906 Nm3/h
Calibrated Flow 41.885 116.23 190.575 Nm3/h
Maximum Flow 83.769 232.46 381.151 Nm3/h
Pressure loss at req. Flow min. 0.02 4.21E-3 1.46E-3 mbar
Pressure loss at req. Flow nom. 3.71 0.45 0.13 mbar
Pressure loss at req. Flow max. 5.14 0.62 0.19 mbar
Velocity (meas. tube) at req. Flow min. 2.102 0.855 0.513 m/s
Velocity (meas. tube) at req. Flow nom. 24.03 9.773 5.861 m/s
Velocity (meas. tube) at req. Flow max. 28.23 11.48 6.887 m/s
Meas. error Mass at req. Flow min.*** 1.5 2.49 4.08 %
Meas. error Mass at req. Flow nom.*** n.a. 1.5 1.5 %
Meas. error Mass at req. Flow max.*** n.a. 1.5 1.5 %
Reynolds No. 277 185 176 787 136 902
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
Print date: 29.04.2014 11:10 AM
Applicator®: 10.16.05 / 133
- 5 / 6 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Schaff
Timestamp: --- Review number: ---
Sales order number:
Chart Sheet
Flowmeter : t-mass 65F
Flow Principle Thermal (t-mass)
Meter Size DN 40
Minimum Flow 1.162   Nm3/h
Calibrated Flow 116.23   Nm3/h
Maximum Flow 232.46   Nm3/h
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
Print date: 29.04.2014 11:10 AM
Applicator®: 10.16.05 / 133
- 6 / 6 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : LPG-Schaff
Timestamp: --- Review number: ---
Sales order number:
Corrosion Information
General Parameters
Fluid Propane (Gas) Abrasivity Not abrasive
State Gas
Character Clean Flow Principle Thermal (t-mass)
Interpretation of Data, (M) Material:
A: resistant, 0.05 mm/y (0.002 inches/y)
B: insufficient resistant, 0.5 mm/y (0.02 inches/y)
C: not resistant, 1.3 mm/y (0.05 inches/y)
NR: not recommended
U: unknown
Interpretation of Data, (P) Plastics:
A: resistant, 15% vol. Swelling/y; 15% Loss of Tensile Strength/y
B: insufficient resistant, 30% vol. Swelling/y; 30% Loss of Tensile Strength/y
C: not resistant, 50% vol. Swelling/y; 60% Loss of Tensile Strength/y
NR: not recommended
U: unknown
Temperature
Material (Sensor) * minimum30°C nominal : 30°C maximum : 30°C
(M) CF3M - A 351 A A A
(P) EPDM U U U
(M) Alloy C22/2.4602 A A A
(P) Kalrez A A A
(P) PEEK C C C
(P) PVDF A A A
(M) Stainless steel 316L/316/1.4404 A A A
(P) Viton A A A
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
Print date: 29.04.2014 08:56 AM
Applicator®: 10.16.05 / 133
- 1 / 7 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : NG-Main
Timestamp: --- Review number: ---
Sales order number:
Sizing Sheet
General Parameters
Fluid Natural Gas Ref. Temperature 0 °C
State Gas Ref. Pressure 1.013 bar_a
Character Clean Atmospheric Pressure 1.0132 bar_a
Abrasivity Not abrasive Standard EN/DIN/ISO
Fluid Group (PED) Dangerous Fluid (Fluid group 1)
Operating Conditions
minimum nominal maximum
Requested Flow 50 2 100 2 300 Nm3/h
Pressure 1.6 bar_g
Temperature 30 °C
Density 1.7929 kg/m3
Viscosity 0.01146 cP
Z-factor 0.9955
Sound Velocity 433.5 m/s
Pressure (min/max) 1.6 1.6 bar_g
Temp. (min/max) 30 30 °C
Flowmeter : t-mass 65I
Flow Principle Thermal (t-mass)
Meter Size DN 150
Minimum Flow 37.217   Nm3/h
Calibrated Flow 3 721.665   Nm3/h
Maximum Flow 7 443.33   Nm3/h
Material (sensor) * SS 1.4404 / 316L
Process connection* G 1 A ISO 228 / 1.4404 /316L Thread
PED category ** : Application meets PED (Art.3.3)
  Extended order code
Qty Item Description Extended order code
1 Flowmeter t-mass 65I 65I-20AB
1 Accessory Mounting boss - DK6MB DK6MB-B
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissible
pressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.
Print date: 29.04.2014 08:56 AM
Applicator®: 10.16.05 / 133
- 2 / 7 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : NG-Main
Timestamp: --- Review number: ---
Sales order number:
Sizing Sheet
Sizing and Calculated Results
minimum nominal maximum
Requested Flow 50 2 100 2 300 Nm3/h
Pressure loss 2.33E-5 0.03 0.04 mbar
Velocity (meas. tube) 0.303 12.73 13.94 m/s
Measured error Mass*** 11.2 1.5 1.5 %
Reynolds No. 7 504 315 151 345 165
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
Attention for Flow! Device is used in non-ideal application conditions.
Print date: 29.04.2014 08:56 AM
Applicator®: 10.16.05 / 133
- 3 / 7 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : NG-Main
Timestamp: --- Review number: ---
Sales order number:
Fluid properties sheet
Fluid
Fluid name Natural Gas State Gas
Chemical formula NASA-Langley Calculation standard NEL
Fluid description
Medium character Clean
Fluid group (PED) Dangerous Fluid (Fluid group 1)
Fluid stability Stable
Gas mixture
Component
Fraction
1    Nitrogen (Gas) 2.8   Mole% 4.54   Mass%
2    Carbon dioxide (Gas) 0.21   Mole% 0.54   Mass%
3    Methane (Gas) 91.82   Mole% 85.5   Mass%
4    Ethane (Gas) 4.85   Mole% 8.53   Mass%
5    Propane (Gas) 0.26   Mole% 0.68   Mass%
6    n-Butane (Gas) 0.06   Mole% 0.21   Mass%
7    0   Mole% 0   Mass%
8    0   Mole% 0   Mass%
Basic fluid parameters
Tc (Critical temperature) -77.57   °C
Pc (Critical pressure) 46.1041   bar
Rho_c (Critical density) 168.8   kg/m3
Tm (Melting point) n.a.   °C
Tb (Boiling point) n.a.   °C
Calculated results
Density nom. 1.7929   kg/m3
Molar mass 17.214   kg/kmol
Z-factor nom. 0.9955
Viscosity nom. 0.01146   cP
Sound velocity nom. 433.5   m/s
Thermal capacity nom. 2.153   kJ/(kg*K)
Heat conductivity nom. 0.034   W/(m K)
Vapor pressure nom.   bar_a
Pressure nom. 1.6   bar_g
Temperature nom. 30   °C
 
Reference values:   Normal conditions (SI): Standard conditions (US):
Atmospheric pressure 1.0132   bar_a
Density normal 0.77   kg/m3
Temperature 0   °C
Pressure 1.0132   bar_a
Atmospheric pressure 1.0132   bar_a
Density standard 0.7296   kg/m3
Temperature 59   °F
Pressure 14.696   psi_a
Print date: 29.04.2014 08:56 AM
Applicator®: 10.16.05 / 133
- 4 / 7 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : NG-Main
Timestamp: --- Review number: ---
Sales order number:
Installation sheet
Flowmeter / Accessories
  Extended order code
Qty Item Description Extended order code
1 Flowmeter t-mass 65I 65I-20AB
1 Accessory Mounting boss - DK6MB DK6MB-B
Installation data :
Insertion depth X (scale value) 160.49   mm
Insertion tube length 235   mm
Pipe inner diameter 20°C 158.3   mm
Duct Installation Horizontal
Duct internal height  
Duct internal width  
Wall thickness 5   mm
C1 = Height process connection 60   mm
C2 = Height sensor connection 46   mm
C3 = Height ball valve 0   mm
C = Total height of connection 106   mm
A= Internal diameter or internal height (duct vertical installation) or internal width (duct horizontal installation)
B= Wall thickness
C= Height of connection
*The Enduser is responsible for the correct selection of the piping. Applicator does not calculate necessary pipe wall thickness according to application
data. Endress + Hauser takes no liability for the suitability of the pipe dimensions.
Attention for Flow! Device is used in non-ideal application conditions.
Print date: 29.04.2014 08:56 AM
Applicator®: 10.16.05 / 133
- 5 / 7 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : NG-Main
Timestamp: --- Review number: ---
Sales order number:
Tri-Size Sheet
General Parameters
Fluid Natural Gas Ref. Temperature 0 °C
State Gas Ref. Pressure 1.013 bar_a
Character Clean Atmospheric Pressure 1.0132 bar_a
Abrasivity Not abrasive Standard EN/DIN/ISO
Fluid Group (PED) Dangerous Fluid (Fluid group 1)
Sizing and Calculated Results
Next Smaller Size Current Size Next Bigger Size
Flow meter t-mass 65I t-mass 65I t-mass 65I
Flow Principle Thermal (t-mass) Thermal (t-mass) Thermal (t-mass)
Meter Size DN 100 DN 150 DN 200
Process connection* G 1 A ISO 228 / 1.4404 /316L G 1 A ISO 228 / 1.4404 /316L G 1 A ISO 228 / 1.4404 /316L
Minimum Flow 16.156 37.217 64.936 Nm3/h
Calibrated Flow 1 615.638 3 721.665 6 493.57 Nm3/h
Maximum Flow 3 231.28 7 443.33 12 987.1 Nm3/h
Pressure loss at req. Flow min. 1.67E-4 2.33E-5 6.6E-6 mbar
Pressure loss at req. Flow nom. 0.26 0.03 9.66E-3 mbar
Pressure loss at req. Flow max. 0.31 0.04 0.01 mbar
Velocity (meas. tube) at req. Flow min. 0.698 0.303 0.174 m/s
Velocity (meas. tube) at req. Flow nom. 29.32 12.73 7.295 m/s
Velocity (meas. tube) at req. Flow max. 32.11 13.94 7.99 m/s
Meas. error Mass at req. Flow min.*** 4.85 11.2 n.a. %
Meas. error Mass at req. Flow nom.*** 3.6 1.5 1.5 %
Meas. error Mass at req. Flow max.*** 4.47 1.5 1.5 %
Reynolds No. 478 316 315 151 238 586
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
Print date: 29.04.2014 08:56 AM
Applicator®: 10.16.05 / 133
- 6 / 7 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : NG-Main
Timestamp: --- Review number: ---
Sales order number:
Chart Sheet
Flowmeter : t-mass 65I
Flow Principle Thermal (t-mass)
Meter Size DN 150
Minimum Flow 37.217   Nm3/h
Calibrated Flow 3 721.665   Nm3/h
Maximum Flow 7 443.33   Nm3/h
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
Print date: 29.04.2014 08:56 AM
Applicator®: 10.16.05 / 133
- 7 / 7 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : NG-Main
Timestamp: --- Review number: ---
Sales order number:
Corrosion Information
General Parameters
Fluid Natural Gas Abrasivity Not abrasive
State Gas
Character Clean Flow Principle Thermal (t-mass)
Interpretation of Data, (M) Material:
A: resistant, 0.05 mm/y (0.002 inches/y)
B: insufficient resistant, 0.5 mm/y (0.02 inches/y)
C: not resistant, 1.3 mm/y (0.05 inches/y)
NR: not recommended
U: unknown
Interpretation of Data, (P) Plastics:
A: resistant, 15% vol. Swelling/y; 15% Loss of Tensile Strength/y
B: insufficient resistant, 30% vol. Swelling/y; 30% Loss of Tensile Strength/y
C: not resistant, 50% vol. Swelling/y; 60% Loss of Tensile Strength/y
NR: not recommended
U: unknown
Temperature
Material (Sensor) * minimum30°C nominal : 30°C maximum : 30°C
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
Print date: 29.04.2014 09:18 AM
Applicator®: 10.16.05 / 133
- 1 / 6 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : NG-KHX
Timestamp: --- Review number: ---
Sales order number:
Sizing Sheet
General Parameters
Fluid Natural Gas Ref. Temperature 0 °C
State Gas Ref. Pressure 1.013 bar_a
Character Clean Atmospheric Pressure 1.0132 bar_a
Abrasivity Not abrasive Standard EN/DIN/ISO
Fluid Group (PED) Dangerous Fluid (Fluid group 1)
Operating Conditions
minimum nominal maximum
Requested Flow 84 1 050 1 150 Nm3/h
Pressure 1.6 bar_g
Temperature 30 °C
Density 1.7929 kg/m3
Viscosity 0.01146 cP
Z-factor 0.9955
Sound Velocity 433.5 m/s
Pressure (min/max) 1.6 1.6 bar_g
Temp. (min/max) 30 30 °C
Flowmeter : t-mass 65F
Flow Principle Thermal (t-mass)
Meter Size DN 100
Minimum Flow 17.084   Nm3/h
Calibrated Flow 1 708.397   Nm3/h
Maximum Flow 3 416.79   Nm3/h
Material (sensor) * SS 1.4404 / 316L
Process connection* PN 16 EN 1092-1 B1 / 1.4404/316L Flange
PED category ** : Application is Cat. II
  Extended order code
Qty Item Description Extended order code
1 Flowmeter t-mass 65F 65F1H-AB**GP
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissible
pressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.
Print date: 29.04.2014 09:18 AM
Applicator®: 10.16.05 / 133
- 2 / 6 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : NG-KHX
Timestamp: --- Review number: ---
Sales order number:
Sizing Sheet
Sizing and Calculated Results
minimum nominal maximum
Requested Flow 84 1 050 1 150 Nm3/h
Pressure loss 3.6E-3 0.39 0.47 mbar
Velocity (meas. tube) 1.328 16.61 18.19 m/s
Measured error Mass*** 3.05 1.5 1.5 %
Reynolds No. 20 363 254 533 278 774
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
Print date: 29.04.2014 09:18 AM
Applicator®: 10.16.05 / 133
- 3 / 6 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : NG-KHX
Timestamp: --- Review number: ---
Sales order number:
Fluid properties sheet
Fluid
Fluid name Natural Gas State Gas
Chemical formula NASA-Langley Calculation standard NEL
Fluid description
Medium character Clean
Fluid group (PED) Dangerous Fluid (Fluid group 1)
Fluid stability Stable
Gas mixture
Component
Fraction
1    Nitrogen (Gas) 2.8   Mole% 4.54   Mass%
2    Carbon dioxide (Gas) 0.21   Mole% 0.54   Mass%
3    Methane (Gas) 91.82   Mole% 85.5   Mass%
4    Ethane (Gas) 4.85   Mole% 8.53   Mass%
5    Propane (Gas) 0.26   Mole% 0.68   Mass%
6    n-Butane (Gas) 0.06   Mole% 0.21   Mass%
7    0   Mole% 0   Mass%
8    0   Mole% 0   Mass%
Basic fluid parameters
Tc (Critical temperature) -77.57   °C
Pc (Critical pressure) 46.1041   bar
Rho_c (Critical density) 168.8   kg/m3
Tm (Melting point) n.a.   °C
Tb (Boiling point) n.a.   °C
Calculated results
Density nom. 1.7929   kg/m3
Molar mass 17.214   kg/kmol
Z-factor nom. 0.9955
Viscosity nom. 0.01146   cP
Sound velocity nom. 433.5   m/s
Thermal capacity nom. 2.153   kJ/(kg*K)
Heat conductivity nom. 0.034   W/(m K)
Vapor pressure nom.   bar_a
Pressure nom. 1.6   bar_g
Temperature nom. 30   °C
 
Reference values:   Normal conditions (SI): Standard conditions (US):
Atmospheric pressure 1.0132   bar_a
Density normal 0.77   kg/m3
Temperature 0   °C
Pressure 1.0132   bar_a
Atmospheric pressure 1.0132   bar_a
Density standard 0.7296   kg/m3
Temperature 59   °F
Pressure 14.696   psi_a
Print date: 29.04.2014 09:18 AM
Applicator®: 10.16.05 / 133
- 4 / 6 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : NG-KHX
Timestamp: --- Review number: ---
Sales order number:
Tri-Size Sheet
General Parameters
Fluid Natural Gas Ref. Temperature 0 °C
State Gas Ref. Pressure 1.013 bar_a
Character Clean Atmospheric Pressure 1.0132 bar_a
Abrasivity Not abrasive Standard EN/DIN/ISO
Fluid Group (PED) Dangerous Fluid (Fluid group 1)
Sizing and Calculated Results
Next Smaller Size Current Size Next Bigger Size
Flow meter t-mass 65F t-mass 65F
Flow Principle Thermal (t-mass) Thermal (t-mass)
Meter Size DN 80 DN 100
Process connection* PN 40 EN 1092-1
B1 / 1.4404/316L
PN 16 EN 1092-1
B1 / 1.4404/316L
Minimum Flow 9.746 17.084 Nm3/h
Calibrated Flow 974.591 1 708.397 Nm3/h
Maximum Flow 1 949.18 3 416.79 Nm3/h
Pressure loss at req. Flow min. 9.13E-3 3.6E-3 mbar
Pressure loss at req. Flow nom. 1.09 0.39 mbar
Pressure loss at req. Flow max. 1.31 0.47 mbar
Velocity (meas. tube) at req. Flow min. 2.135 1.328 m/s
Velocity (meas. tube) at req. Flow nom. 26.69 16.61 m/s
Velocity (meas. tube) at req. Flow max. 29.23 18.19 m/s
Meas. error Mass at req. Flow min.*** 1.74 3.05 %
Meas. error Mass at req. Flow nom.*** 2.04 1.5 %
Meas. error Mass at req. Flow max.*** 2.76 1.5 %
Reynolds No. 322 693 254 533
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
Print date: 29.04.2014 09:18 AM
Applicator®: 10.16.05 / 133
- 5 / 6 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : NG-KHX
Timestamp: --- Review number: ---
Sales order number:
Chart Sheet
Flowmeter : t-mass 65F
Flow Principle Thermal (t-mass)
Meter Size DN 100
Minimum Flow 17.084   Nm3/h
Calibrated Flow 1 708.397   Nm3/h
Maximum Flow 3 416.79   Nm3/h
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
Print date: 29.04.2014 09:18 AM
Applicator®: 10.16.05 / 133
- 6 / 6 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : NG-KHX
Timestamp: --- Review number: ---
Sales order number:
Corrosion Information
General Parameters
Fluid Natural Gas Abrasivity Not abrasive
State Gas
Character Clean Flow Principle Thermal (t-mass)
Interpretation of Data, (M) Material:
A: resistant, 0.05 mm/y (0.002 inches/y)
B: insufficient resistant, 0.5 mm/y (0.02 inches/y)
C: not resistant, 1.3 mm/y (0.05 inches/y)
NR: not recommended
U: unknown
Interpretation of Data, (P) Plastics:
A: resistant, 15% vol. Swelling/y; 15% Loss of Tensile Strength/y
B: insufficient resistant, 30% vol. Swelling/y; 30% Loss of Tensile Strength/y
C: not resistant, 50% vol. Swelling/y; 60% Loss of Tensile Strength/y
NR: not recommended
U: unknown
Temperature
Material (Sensor) * minimum30°C nominal : 30°C maximum : 30°C
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
Print date: 29.04.2014 09:22 AM
Applicator®: 10.16.05 / 133
- 1 / 6 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : NG-Gas Genset
Timestamp: --- Review number: ---
Sales order number:
Sizing Sheet
General Parameters
Fluid Natural Gas Ref. Temperature 0 °C
State Gas Ref. Pressure 1.013 bar_a
Character Clean Atmospheric Pressure 1.0132 bar_a
Abrasivity Not abrasive Standard EN/DIN/ISO
Fluid Group (PED) Dangerous Fluid (Fluid group 1)
Operating Conditions
minimum nominal maximum
Requested Flow 50 650 700 Nm3/h
Pressure 1.6 bar_g
Temperature 30 °C
Density 1.7929 kg/m3
Viscosity 0.01146 cP
Z-factor 0.9955
Sound Velocity 433.5 m/s
Pressure (min/max) 1.6 1.6 bar_g
Temp. (min/max) 30 30 °C
Flowmeter : t-mass 65F
Flow Principle Thermal (t-mass)
Meter Size DN 80
Minimum Flow 9.746   Nm3/h
Calibrated Flow 974.591   Nm3/h
Maximum Flow 1 949.18   Nm3/h
Material (sensor) * SS 1.4404 / 316L
Process connection* PN 40 EN 1092-1 B1 / 1.4404/316L Flange
PED category ** : Application is Cat. II
  Extended order code
Qty Item Description Extended order code
1 Flowmeter t-mass 65F 65F80-AE**GP
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissible
pressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.
Print date: 29.04.2014 09:22 AM
Applicator®: 10.16.05 / 133
- 2 / 6 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : NG-Gas Genset
Timestamp: --- Review number: ---
Sales order number:
Sizing Sheet
Sizing and Calculated Results
minimum nominal maximum
Requested Flow 50 650 700 Nm3/h
Pressure loss 3.68E-3 0.42 0.49 mbar
Velocity (meas. tube) 1.271 16.52 17.79 m/s
Measured error Mass*** 2.92 1.5 1.5 %
Reynolds No. 15 366 199 763 215 129
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
Print date: 29.04.2014 09:22 AM
Applicator®: 10.16.05 / 133
- 3 / 6 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : NG-Gas Genset
Timestamp: --- Review number: ---
Sales order number:
Fluid properties sheet
Fluid
Fluid name Natural Gas State Gas
Chemical formula NASA-Langley Calculation standard NEL
Fluid description
Medium character Clean
Fluid group (PED) Dangerous Fluid (Fluid group 1)
Fluid stability Stable
Gas mixture
Component
Fraction
1    Nitrogen (Gas) 2.8   Mole% 4.54   Mass%
2    Carbon dioxide (Gas) 0.21   Mole% 0.54   Mass%
3    Methane (Gas) 91.82   Mole% 85.5   Mass%
4    Ethane (Gas) 4.85   Mole% 8.53   Mass%
5    Propane (Gas) 0.26   Mole% 0.68   Mass%
6    n-Butane (Gas) 0.06   Mole% 0.21   Mass%
7    0   Mole% 0   Mass%
8    0   Mole% 0   Mass%
Basic fluid parameters
Tc (Critical temperature) -77.57   °C
Pc (Critical pressure) 46.1041   bar
Rho_c (Critical density) 168.8   kg/m3
Tm (Melting point) n.a.   °C
Tb (Boiling point) n.a.   °C
Calculated results
Density nom. 1.7929   kg/m3
Molar mass 17.214   kg/kmol
Z-factor nom. 0.9955
Viscosity nom. 0.01146   cP
Sound velocity nom. 433.5   m/s
Thermal capacity nom. 2.153   kJ/(kg*K)
Heat conductivity nom. 0.034   W/(m K)
Vapor pressure nom.   bar_a
Pressure nom. 1.6   bar_g
Temperature nom. 30   °C
 
Reference values:   Normal conditions (SI): Standard conditions (US):
Atmospheric pressure 1.0132   bar_a
Density normal 0.77   kg/m3
Temperature 0   °C
Pressure 1.0132   bar_a
Atmospheric pressure 1.0132   bar_a
Density standard 0.7296   kg/m3
Temperature 59   °F
Pressure 14.696   psi_a
Print date: 29.04.2014 09:22 AM
Applicator®: 10.16.05 / 133
- 4 / 6 -
 
Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).
Applicator Sizing - Flow
Project : Instruments Add on BMS
Customer: Pepsico C.Project No.: WNV_00234
Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830
eMail: sarfraz@wattnvolt.com.pk
TAG : NG-Gas Genset
Timestamp: --- Review number: ---
Sales order number:
Tri-Size Sheet
General Parameters
Fluid Natural Gas Ref. Temperature 0 °C
State Gas Ref. Pressure 1.013 bar_a
Character Clean Atmospheric Pressure 1.0132 bar_a
Abrasivity Not abrasive Standard EN/DIN/ISO
Fluid Group (PED) Dangerous Fluid (Fluid group 1)
Sizing and Calculated Results
Next Smaller Size Current Size Next Bigger Size
Flow meter t-mass 65F t-mass 65F t-mass 65F
Flow Principle Thermal (t-mass) Thermal (t-mass) Thermal (t-mass)
Meter Size DN 50 DN 80 DN 100
Process connection* PN 40 EN 1092-1
B1 / 1.4404/316L
PN 40 EN 1092-1
B1 / 1.4404/316L
PN 16 EN 1092-1
B1 / 1.4404/316L
Minimum Flow 4.146 9.746 17.084 Nm3/h
Calibrated Flow 414.571 974.591 1 708.397 Nm3/h
Maximum Flow 829.142 1 949.18 3 416.79 Nm3/h
Pressure loss at req. Flow min. 0.02 3.68E-3 1.45E-3 mbar
Pressure loss at req. Flow nom. 2.93 0.42 0.15 mbar
Pressure loss at req. Flow max. 3.39 0.49 0.18 mbar
Velocity (meas. tube) at req. Flow min. 3.137 1.271 0.791 m/s
Velocity (meas. tube) at req. Flow nom. 40.79 16.52 10.28 m/s
Velocity (meas. tube) at req. Flow max. 43.92 17.79 11.07 m/s
Meas. error Mass at req. Flow min.*** 1.5 2.92 5.13 %
Meas. error Mass at req. Flow nom.*** n.a. 1.5 1.5 %
Meas. error Mass at req. Flow max.*** n.a. 1.5 1.5 %
Reynolds No. 313 855 199 763 157 568
*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and
assumes no liability for the corrosion resistance of the materials selected here for the application described above.
***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in
technical documentation.
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration
Application Flow Sizing and Order Code Configuration

More Related Content

What's hot

7 quiz prestudy guide 1
7 quiz prestudy guide 17 quiz prestudy guide 1
7 quiz prestudy guide 1Achmad Walid
 
Yokogawa digital YEWFLOW Vortex Flowmeters
Yokogawa digital YEWFLOW Vortex FlowmetersYokogawa digital YEWFLOW Vortex Flowmeters
Yokogawa digital YEWFLOW Vortex FlowmetersMiller Energy, Inc.
 
Forberg scientific mi facility brochure 2012 single page display
Forberg scientific mi facility brochure 2012 single page displayForberg scientific mi facility brochure 2012 single page display
Forberg scientific mi facility brochure 2012 single page displayJohn Peters
 
MISTRAS Service Brochure v2 pages_web
MISTRAS Service Brochure v2 pages_webMISTRAS Service Brochure v2 pages_web
MISTRAS Service Brochure v2 pages_webQue Timm
 
Parker Kittiwake - Parker-branded Product Overview
Parker Kittiwake - Parker-branded Product OverviewParker Kittiwake - Parker-branded Product Overview
Parker Kittiwake - Parker-branded Product OverviewParker Kittiwake
 
VEGA The Yellow World Of Pressure Measurement - Technology Brochure
VEGA The Yellow World Of Pressure Measurement - Technology BrochureVEGA The Yellow World Of Pressure Measurement - Technology Brochure
VEGA The Yellow World Of Pressure Measurement - Technology BrochureThorne & Derrick UK
 
Flow Meters Micronics Portable Fixed Flow Meters Ultrasonic Clamp On
Flow Meters Micronics Portable Fixed Flow Meters Ultrasonic Clamp OnFlow Meters Micronics Portable Fixed Flow Meters Ultrasonic Clamp On
Flow Meters Micronics Portable Fixed Flow Meters Ultrasonic Clamp OnThorne & Derrick UK
 
Risk analysis and environmental hazard management
Risk analysis and environmental hazard managementRisk analysis and environmental hazard management
Risk analysis and environmental hazard managementeSAT Publishing House
 
Cashco - Válvula de controle e reguladores sanitários
Cashco - Válvula de controle e reguladores sanitáriosCashco - Válvula de controle e reguladores sanitários
Cashco - Válvula de controle e reguladores sanitáriosRenan Sehn Santos
 
ASCO Solenoid Valves Catalog
ASCO Solenoid Valves CatalogASCO Solenoid Valves Catalog
ASCO Solenoid Valves CatalogCarotek
 
Rtk katalog gb
Rtk katalog gbRtk katalog gb
Rtk katalog gbLy Jolie
 
Donaldson filter
Donaldson filterDonaldson filter
Donaldson filterDNTMb Inc.
 
Cashco - Reguladores Industriais
Cashco - Reguladores IndustriaisCashco - Reguladores Industriais
Cashco - Reguladores IndustriaisRenan Sehn Santos
 
Flexim - Ultrasonic Clamp-on Hazardous Area Flow Meters - Brochure
Flexim - Ultrasonic Clamp-on Hazardous Area Flow Meters - BrochureFlexim - Ultrasonic Clamp-on Hazardous Area Flow Meters - Brochure
Flexim - Ultrasonic Clamp-on Hazardous Area Flow Meters - BrochureThorne & Derrick UK
 
2017 respirators ppe
2017 respirators ppe2017 respirators ppe
2017 respirators ppeJohn Newquist
 

What's hot (20)

7 quiz prestudy guide 1
7 quiz prestudy guide 17 quiz prestudy guide 1
7 quiz prestudy guide 1
 
Yokogawa digital YEWFLOW Vortex Flowmeters
Yokogawa digital YEWFLOW Vortex FlowmetersYokogawa digital YEWFLOW Vortex Flowmeters
Yokogawa digital YEWFLOW Vortex Flowmeters
 
Forberg scientific mi facility brochure 2012 single page display
Forberg scientific mi facility brochure 2012 single page displayForberg scientific mi facility brochure 2012 single page display
Forberg scientific mi facility brochure 2012 single page display
 
MISTRAS Service Brochure v2 pages_web
MISTRAS Service Brochure v2 pages_webMISTRAS Service Brochure v2 pages_web
MISTRAS Service Brochure v2 pages_web
 
Parker Kittiwake - Parker-branded Product Overview
Parker Kittiwake - Parker-branded Product OverviewParker Kittiwake - Parker-branded Product Overview
Parker Kittiwake - Parker-branded Product Overview
 
VEGA The Yellow World Of Pressure Measurement - Technology Brochure
VEGA The Yellow World Of Pressure Measurement - Technology BrochureVEGA The Yellow World Of Pressure Measurement - Technology Brochure
VEGA The Yellow World Of Pressure Measurement - Technology Brochure
 
Flow Meters Micronics Portable Fixed Flow Meters Ultrasonic Clamp On
Flow Meters Micronics Portable Fixed Flow Meters Ultrasonic Clamp OnFlow Meters Micronics Portable Fixed Flow Meters Ultrasonic Clamp On
Flow Meters Micronics Portable Fixed Flow Meters Ultrasonic Clamp On
 
Catalogo de filtros
Catalogo de filtrosCatalogo de filtros
Catalogo de filtros
 
Risk analysis and environmental hazard management
Risk analysis and environmental hazard managementRisk analysis and environmental hazard management
Risk analysis and environmental hazard management
 
Cashco - Válvula de controle e reguladores sanitários
Cashco - Válvula de controle e reguladores sanitáriosCashco - Válvula de controle e reguladores sanitários
Cashco - Válvula de controle e reguladores sanitários
 
ASCO Solenoid Valves Catalog
ASCO Solenoid Valves CatalogASCO Solenoid Valves Catalog
ASCO Solenoid Valves Catalog
 
Chst prep core 2016
Chst prep core 2016Chst prep core 2016
Chst prep core 2016
 
560 000-gc-s-012 4
560 000-gc-s-012 4560 000-gc-s-012 4
560 000-gc-s-012 4
 
Rtk katalog gb
Rtk katalog gbRtk katalog gb
Rtk katalog gb
 
Donaldson filter
Donaldson filterDonaldson filter
Donaldson filter
 
Micronics U1000 Fixed Clamp On Ultrasonic Flow Meter
Micronics U1000 Fixed Clamp On Ultrasonic Flow MeterMicronics U1000 Fixed Clamp On Ultrasonic Flow Meter
Micronics U1000 Fixed Clamp On Ultrasonic Flow Meter
 
Cashco - Reguladores Industriais
Cashco - Reguladores IndustriaisCashco - Reguladores Industriais
Cashco - Reguladores Industriais
 
Flexim - Ultrasonic Clamp-on Hazardous Area Flow Meters - Brochure
Flexim - Ultrasonic Clamp-on Hazardous Area Flow Meters - BrochureFlexim - Ultrasonic Clamp-on Hazardous Area Flow Meters - Brochure
Flexim - Ultrasonic Clamp-on Hazardous Area Flow Meters - Brochure
 
2017 respirators ppe
2017 respirators ppe2017 respirators ppe
2017 respirators ppe
 
Sil in de praktijk syllabus
Sil in de praktijk syllabusSil in de praktijk syllabus
Sil in de praktijk syllabus
 

Similar to Application Flow Sizing and Order Code Configuration

Compressed Air Flowmeters
Compressed Air FlowmetersCompressed Air Flowmeters
Compressed Air FlowmetersTesto Limited
 
Docslide.us gd air-compressors
Docslide.us gd air-compressorsDocslide.us gd air-compressors
Docslide.us gd air-compressorsbui dinh tuong
 
Download-manuals-ground water-manual-gw-volume4referencemanualgeo-hydrology
 Download-manuals-ground water-manual-gw-volume4referencemanualgeo-hydrology Download-manuals-ground water-manual-gw-volume4referencemanualgeo-hydrology
Download-manuals-ground water-manual-gw-volume4referencemanualgeo-hydrologyhydrologyproject001
 
Hướng dẫn sử dụng Testo 312-3
Hướng dẫn sử dụng Testo 312-3Hướng dẫn sử dụng Testo 312-3
Hướng dẫn sử dụng Testo 312-3Tenmars Việt Nam
 
Netzsch-BY-Manual.pdf
Netzsch-BY-Manual.pdfNetzsch-BY-Manual.pdf
Netzsch-BY-Manual.pdfEder Ferreira
 
VEGA Process Measurement (Level, Limit Level & Pressure) - Oil & Gas Offshore
VEGA Process Measurement (Level, Limit Level & Pressure) - Oil & Gas OffshoreVEGA Process Measurement (Level, Limit Level & Pressure) - Oil & Gas Offshore
VEGA Process Measurement (Level, Limit Level & Pressure) - Oil & Gas OffshoreThorne & Derrick UK
 
GILL Instruments' and MEASNET - WindObserver, WindMaster, WindMaster Pro
GILL Instruments' and MEASNET -  WindObserver, WindMaster, WindMaster ProGILL Instruments' and MEASNET -  WindObserver, WindMaster, WindMaster Pro
GILL Instruments' and MEASNET - WindObserver, WindMaster, WindMaster ProAlexandre Ferrete
 
8.4 PERFORMANCE QUALIFICATION PROTOCOL FOR DISPENSING BOOTH (1).pdf
8.4 PERFORMANCE QUALIFICATION PROTOCOL FOR DISPENSING BOOTH (1).pdf8.4 PERFORMANCE QUALIFICATION PROTOCOL FOR DISPENSING BOOTH (1).pdf
8.4 PERFORMANCE QUALIFICATION PROTOCOL FOR DISPENSING BOOTH (1).pdfabdo badr
 
Density Compensation Module for Drexelbrook Universal IV Water Cut Monitor
Density Compensation Module for Drexelbrook Universal IV Water Cut MonitorDensity Compensation Module for Drexelbrook Universal IV Water Cut Monitor
Density Compensation Module for Drexelbrook Universal IV Water Cut MonitorAMETEK STC
 
A Trusted Steam Flow Meter Manufacturer and Supplier- Manas
A Trusted Steam Flow Meter Manufacturer and Supplier- ManasA Trusted Steam Flow Meter Manufacturer and Supplier- Manas
A Trusted Steam Flow Meter Manufacturer and Supplier- ManasManasMicrosystems
 
CVH252009 Series
CVH252009 SeriesCVH252009 Series
CVH252009 SeriesTony Kenny
 
iMovR ZipDesk ANSI/BIFMA X5.5 Test Report
iMovR ZipDesk ANSI/BIFMA X5.5 Test ReportiMovR ZipDesk ANSI/BIFMA X5.5 Test Report
iMovR ZipDesk ANSI/BIFMA X5.5 Test ReportiMovR
 
VEGA Pressure & Level Measurement - Cement Industry Applications
VEGA Pressure & Level Measurement - Cement Industry ApplicationsVEGA Pressure & Level Measurement - Cement Industry Applications
VEGA Pressure & Level Measurement - Cement Industry ApplicationsThorne & Derrick UK
 

Similar to Application Flow Sizing and Order Code Configuration (20)

HIPPS
HIPPSHIPPS
HIPPS
 
Compressed Air Flowmeters
Compressed Air FlowmetersCompressed Air Flowmeters
Compressed Air Flowmeters
 
Smart DP Transmitter with Remote Seal
Smart DP Transmitter with Remote SealSmart DP Transmitter with Remote Seal
Smart DP Transmitter with Remote Seal
 
Docslide.us gd air-compressors
Docslide.us gd air-compressorsDocslide.us gd air-compressors
Docslide.us gd air-compressors
 
Download-manuals-ground water-manual-gw-volume4referencemanualgeo-hydrology
 Download-manuals-ground water-manual-gw-volume4referencemanualgeo-hydrology Download-manuals-ground water-manual-gw-volume4referencemanualgeo-hydrology
Download-manuals-ground water-manual-gw-volume4referencemanualgeo-hydrology
 
UM PROJECT
UM PROJECTUM PROJECT
UM PROJECT
 
Hướng dẫn sử dụng Testo 312-3
Hướng dẫn sử dụng Testo 312-3Hướng dẫn sử dụng Testo 312-3
Hướng dẫn sử dụng Testo 312-3
 
MDP Ab01003
MDP Ab01003MDP Ab01003
MDP Ab01003
 
Netzsch-BY-Manual.pdf
Netzsch-BY-Manual.pdfNetzsch-BY-Manual.pdf
Netzsch-BY-Manual.pdf
 
POS3313-customautomotivetesting
POS3313-customautomotivetestingPOS3313-customautomotivetesting
POS3313-customautomotivetesting
 
VEGA Process Measurement (Level, Limit Level & Pressure) - Oil & Gas Offshore
VEGA Process Measurement (Level, Limit Level & Pressure) - Oil & Gas OffshoreVEGA Process Measurement (Level, Limit Level & Pressure) - Oil & Gas Offshore
VEGA Process Measurement (Level, Limit Level & Pressure) - Oil & Gas Offshore
 
GILL Instruments' and MEASNET - WindObserver, WindMaster, WindMaster Pro
GILL Instruments' and MEASNET -  WindObserver, WindMaster, WindMaster ProGILL Instruments' and MEASNET -  WindObserver, WindMaster, WindMaster Pro
GILL Instruments' and MEASNET - WindObserver, WindMaster, WindMaster Pro
 
8.4 PERFORMANCE QUALIFICATION PROTOCOL FOR DISPENSING BOOTH (1).pdf
8.4 PERFORMANCE QUALIFICATION PROTOCOL FOR DISPENSING BOOTH (1).pdf8.4 PERFORMANCE QUALIFICATION PROTOCOL FOR DISPENSING BOOTH (1).pdf
8.4 PERFORMANCE QUALIFICATION PROTOCOL FOR DISPENSING BOOTH (1).pdf
 
Density Compensation Module for Drexelbrook Universal IV Water Cut Monitor
Density Compensation Module for Drexelbrook Universal IV Water Cut MonitorDensity Compensation Module for Drexelbrook Universal IV Water Cut Monitor
Density Compensation Module for Drexelbrook Universal IV Water Cut Monitor
 
A Trusted Steam Flow Meter Manufacturer and Supplier- Manas
A Trusted Steam Flow Meter Manufacturer and Supplier- ManasA Trusted Steam Flow Meter Manufacturer and Supplier- Manas
A Trusted Steam Flow Meter Manufacturer and Supplier- Manas
 
Hydraulic catalogue
Hydraulic catalogueHydraulic catalogue
Hydraulic catalogue
 
CVH252009 Series
CVH252009 SeriesCVH252009 Series
CVH252009 Series
 
iMovR ZipDesk ANSI/BIFMA X5.5 Test Report
iMovR ZipDesk ANSI/BIFMA X5.5 Test ReportiMovR ZipDesk ANSI/BIFMA X5.5 Test Report
iMovR ZipDesk ANSI/BIFMA X5.5 Test Report
 
LVD report.pdf
LVD report.pdfLVD report.pdf
LVD report.pdf
 
VEGA Pressure & Level Measurement - Cement Industry Applications
VEGA Pressure & Level Measurement - Cement Industry ApplicationsVEGA Pressure & Level Measurement - Cement Industry Applications
VEGA Pressure & Level Measurement - Cement Industry Applications
 

More from Muhammad Sarfraz

More from Muhammad Sarfraz (20)

Atlas Honda Buner
Atlas Honda BunerAtlas Honda Buner
Atlas Honda Buner
 
HMI_1
HMI_1HMI_1
HMI_1
 
PLC Control Panel for HVACR System
PLC Control Panel for HVACR SystemPLC Control Panel for HVACR System
PLC Control Panel for HVACR System
 
PLC_1
PLC_1PLC_1
PLC_1
 
CPU
CPUCPU
CPU
 
Efficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing
Efficient Load Management System (ELMS) with ATS_AMF Generator Control DrawingEfficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing
Efficient Load Management System (ELMS) with ATS_AMF Generator Control Drawing
 
SIEMENS Certification
SIEMENS CertificationSIEMENS Certification
SIEMENS Certification
 
xxxQxxx Quotation Estimate for Electrical Work of Poultry Processing Plant
xxxQxxx Quotation Estimate for Electrical Work of Poultry Processing PlantxxxQxxx Quotation Estimate for Electrical Work of Poultry Processing Plant
xxxQxxx Quotation Estimate for Electrical Work of Poultry Processing Plant
 
Test Bench
Test BenchTest Bench
Test Bench
 
merged
mergedmerged
merged
 
PI&T Conceptual Drawing
PI&T Conceptual DrawingPI&T Conceptual Drawing
PI&T Conceptual Drawing
 
Visio-Drawing
Visio-DrawingVisio-Drawing
Visio-Drawing
 
BMS-walls
BMS-wallsBMS-walls
BMS-walls
 
OutE62
OutE62OutE62
OutE62
 
OLV1 (Short-Circuit Analysis) on Wapda
OLV1 (Short-Circuit Analysis) on WapdaOLV1 (Short-Circuit Analysis) on Wapda
OLV1 (Short-Circuit Analysis) on Wapda
 
OLV1 (Load Flow Analysis) in Synch Mod
OLV1 (Load Flow Analysis) in Synch ModOLV1 (Load Flow Analysis) in Synch Mod
OLV1 (Load Flow Analysis) in Synch Mod
 
Visio-Tobacco Box Tilt Unit
Visio-Tobacco Box Tilt UnitVisio-Tobacco Box Tilt Unit
Visio-Tobacco Box Tilt Unit
 
HMI_1
HMI_1HMI_1
HMI_1
 
ActiveReports Document
ActiveReports DocumentActiveReports Document
ActiveReports Document
 
Plishing Plant Drawing
Plishing Plant DrawingPlishing Plant Drawing
Plishing Plant Drawing
 

Application Flow Sizing and Order Code Configuration

  • 1. Print date: 29.04.2014 11:58 AM Applicator®: 10.16.05 / 133 - 1 / 7 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : LPG-Main Timestamp: --- Review number: --- Sales order number: Sizing Sheet General Parameters Fluid Propane (Gas) Ref. Temperature 0 °C State Gas Ref. Pressure 1.013 bar_a Character Clean Atmospheric Pressure 1.0132 bar_a Abrasivity Not abrasive Standard EN/DIN/ISO Fluid Group (PED) Dangerous Fluid (Fluid group 1) Operating Conditions minimum nominal maximum Requested Flow 18 780 1 229 Nm3/h Pressure 1.2 bar_g Temperature 30 °C Density 4.0131 kg/m3 Viscosity 0.00845 cP Z-factor 0.9649 Sound Velocity 248.7 m/s Pressure (min/max) 1.2 1.2 bar_g Temp. (min/max) 30 30 °C Flowmeter : t-mass 65I Flow Principle Thermal (t-mass) Meter Size DN 150 Minimum Flow 17.108   Nm3/h Calibrated Flow 1 710.824   Nm3/h Maximum Flow 3 421.65   Nm3/h Material (sensor) * SS 1.4404 / 316L Process connection* G 1 A ISO 228 / 1.4404 /316L Thread PED category ** : Application meets PED (Art.3.3)   Extended order code Qty Item Description Extended order code 1 Flowmeter t-mass 65I 65I-20AB 1 Accessory Mounting boss - DK6MB DK6MB-B *The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and assumes no liability for the corrosion resistance of the materials selected here for the application described above. ** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissible pressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.
  • 2. Print date: 29.04.2014 11:58 AM Applicator®: 10.16.05 / 133 - 2 / 7 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : LPG-Main Timestamp: --- Review number: --- Sales order number: Sizing Sheet Sizing and Calculated Results minimum nominal maximum Requested Flow 18 780 1 229 Nm3/h Pressure loss 9.08E-6 0.01 0.04 mbar Velocity (meas. tube) 0.127 5.52 8.697 m/s Measured error Mass*** 14.3 1.5 1.5 % Reynolds No. 9 574 414 858 653 668 ***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in technical documentation. Attention for Flow! Device is used in non-ideal application conditions.
  • 3. Print date: 29.04.2014 11:58 AM Applicator®: 10.16.05 / 133 - 3 / 7 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : LPG-Main Timestamp: --- Review number: --- Sales order number: Fluid properties sheet Fluid Fluid name Propane (Gas) State Gas Chemical formula CH3-CH2-CH3 Calculation standard NEL Fluid description Medium character Clean Fluid group (PED) Dangerous Fluid (Fluid group 1) Fluid stability Stable Gas mixture Component Fraction 1    Propane (Gas) 100   Mole% 100   Mass% 2    0   Mole% 0   Mass% 3    0   Mole% 0   Mass% 4    0   Mole% 0   Mass% 5    0   Mole% 0   Mass% 6    0   Mole% 0   Mass% 7    0   Mole% 0   Mass% 8    0   Mole% 0   Mass% Basic fluid parameters Tc (Critical temperature) 96.69   °C Pc (Critical pressure) 42.47   bar Rho_c (Critical density) 217   kg/m3 Tm (Melting point) -187.7   °C Tb (Boiling point) -42.11   °C Calculated results Density nom. 4.0131   kg/m3 Molar mass 44.096   kg/kmol Z-factor nom. 0.9649 Viscosity nom. 0.00845   cP Sound velocity nom. 248.7   m/s Thermal capacity nom. 1.742   kJ/(kg*K) Heat conductivity nom. 0.018   W/(m K) Vapor pressure nom. 10.815   bar_a Pressure nom. 1.2   bar_g Temperature nom. 30   °C   Reference values:   Normal conditions (SI): Standard conditions (US): Atmospheric pressure 1.0132   bar_a Density normal 2.0122   kg/m3 Temperature 0   °C Pressure 1.0132   bar_a Atmospheric pressure 1.0132   bar_a Density standard 1.9005   kg/m3 Temperature 59   °F Pressure 14.696   psi_a
  • 4. Print date: 29.04.2014 11:58 AM Applicator®: 10.16.05 / 133 - 4 / 7 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : LPG-Main Timestamp: --- Review number: --- Sales order number: Installation sheet Flowmeter / Accessories   Extended order code Qty Item Description Extended order code 1 Flowmeter t-mass 65I 65I-20AB 1 Accessory Mounting boss - DK6MB DK6MB-B Installation data : Insertion depth X (scale value) 160.49   mm Insertion tube length 235   mm Pipe inner diameter 20°C 158.3   mm Duct Installation Horizontal Duct internal height   Duct internal width   Wall thickness 5   mm C1 = Height process connection 60   mm C2 = Height sensor connection 46   mm C3 = Height ball valve 0   mm C = Total height of connection 106   mm A= Internal diameter or internal height (duct vertical installation) or internal width (duct horizontal installation) B= Wall thickness C= Height of connection *The Enduser is responsible for the correct selection of the piping. Applicator does not calculate necessary pipe wall thickness according to application data. Endress + Hauser takes no liability for the suitability of the pipe dimensions. Attention for Flow! Device is used in non-ideal application conditions.
  • 5. Print date: 29.04.2014 11:58 AM Applicator®: 10.16.05 / 133 - 5 / 7 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : LPG-Main Timestamp: --- Review number: --- Sales order number: Tri-Size Sheet General Parameters Fluid Propane (Gas) Ref. Temperature 0 °C State Gas Ref. Pressure 1.013 bar_a Character Clean Atmospheric Pressure 1.0132 bar_a Abrasivity Not abrasive Standard EN/DIN/ISO Fluid Group (PED) Dangerous Fluid (Fluid group 1) Sizing and Calculated Results Next Smaller Size Current Size Next Bigger Size Flow meter t-mass 65I t-mass 65I t-mass 65I Flow Principle Thermal (t-mass) Thermal (t-mass) Thermal (t-mass) Meter Size DN 100 DN 150 DN 200 Process connection* G 1 A ISO 228 / 1.4404 /316L G 1 A ISO 228 / 1.4404 /316L G 1 A ISO 228 / 1.4404 /316L Minimum Flow 7.427 17.108 29.85 Nm3/h Calibrated Flow 742.698 1 710.824 2 985.049 Nm3/h Maximum Flow 1 485.4 3 421.65 5 970.1 Nm3/h Pressure loss at req. Flow min. 6.42E-5 9.08E-6 2.49E-6 mbar Pressure loss at req. Flow nom. 0.11 0.01 4.14E-3 mbar Pressure loss at req. Flow max. 0.27 0.04 0.01 mbar Velocity (meas. tube) at req. Flow min. 0.293 0.127 0.073 m/s Velocity (meas. tube) at req. Flow nom. 12.72 5.52 3.164 m/s Velocity (meas. tube) at req. Flow max. 20.03 8.697 4.985 m/s Meas. error Mass at req. Flow min.*** 6.19 14.3 n.a. % Meas. error Mass at req. Flow nom.*** 1.85 1.5 1.5 % Meas. error Mass at req. Flow max.*** n.a. 1.5 1.5 % Reynolds No. 629 646 414 858 314 070 *The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and assumes no liability for the corrosion resistance of the materials selected here for the application described above. ***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in technical documentation.
  • 6. Print date: 29.04.2014 11:58 AM Applicator®: 10.16.05 / 133 - 6 / 7 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : LPG-Main Timestamp: --- Review number: --- Sales order number: Chart Sheet Flowmeter : t-mass 65I Flow Principle Thermal (t-mass) Meter Size DN 150 Minimum Flow 17.108   Nm3/h Calibrated Flow 1 710.824   Nm3/h Maximum Flow 3 421.65   Nm3/h ***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in technical documentation.
  • 7. Print date: 29.04.2014 11:58 AM Applicator®: 10.16.05 / 133 - 7 / 7 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : LPG-Main Timestamp: --- Review number: --- Sales order number: Corrosion Information General Parameters Fluid Propane (Gas) Abrasivity Not abrasive State Gas Character Clean Flow Principle Thermal (t-mass) Interpretation of Data, (M) Material: A: resistant, 0.05 mm/y (0.002 inches/y) B: insufficient resistant, 0.5 mm/y (0.02 inches/y) C: not resistant, 1.3 mm/y (0.05 inches/y) NR: not recommended U: unknown Interpretation of Data, (P) Plastics: A: resistant, 15% vol. Swelling/y; 15% Loss of Tensile Strength/y B: insufficient resistant, 30% vol. Swelling/y; 30% Loss of Tensile Strength/y C: not resistant, 50% vol. Swelling/y; 60% Loss of Tensile Strength/y NR: not recommended U: unknown Temperature Material (Sensor) * minimum30°C nominal : 30°C maximum : 30°C (M) CF3M - A 351 A A A (P) EPDM U U U (M) Alloy C22/2.4602 A A A (P) Kalrez A A A (P) PEEK C C C (P) PVDF A A A (M) Stainless steel 316L/316/1.4404 A A A (P) Viton A A A *The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and assumes no liability for the corrosion resistance of the materials selected here for the application described above.
  • 8. Print date: 29.04.2014 12:00 PM Applicator®: 10.16.05 / 133 - 1 / 7 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : LPG-KHX Timestamp: --- Review number: --- Sales order number: Sizing Sheet General Parameters Fluid Propane (Gas) Ref. Temperature 0 °C State Gas Ref. Pressure 1.013 bar_a Character Clean Atmospheric Pressure 1.0132 bar_a Abrasivity Not abrasive Standard EN/DIN/ISO Fluid Group (PED) Dangerous Fluid (Fluid group 1) Operating Conditions minimum nominal maximum Requested Flow 18 780 1 229 Nm3/h Pressure 1.2 bar_g Temperature 30 °C Density 4.0131 kg/m3 Viscosity 0.00845 cP Z-factor 0.9649 Sound Velocity 248.7 m/s Pressure (min/max) 1.2 1.2 bar_g Temp. (min/max) 30 30 °C Flowmeter : t-mass 65I Flow Principle Thermal (t-mass) Meter Size DN 150 Minimum Flow 17.108   Nm3/h Calibrated Flow 1 710.824   Nm3/h Maximum Flow 3 421.65   Nm3/h Material (sensor) * SS 1.4404 / 316L Process connection* G 1 A ISO 228 / 1.4404 /316L Thread PED category ** : Application meets PED (Art.3.3)   Extended order code Qty Item Description Extended order code 1 Flowmeter t-mass 65I 65I-20AB 1 Accessory Mounting boss - DK6MB DK6MB-B *The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and assumes no liability for the corrosion resistance of the materials selected here for the application described above. ** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissible pressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.
  • 9. Print date: 29.04.2014 12:00 PM Applicator®: 10.16.05 / 133 - 2 / 7 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : LPG-KHX Timestamp: --- Review number: --- Sales order number: Sizing Sheet Sizing and Calculated Results minimum nominal maximum Requested Flow 18 780 1 229 Nm3/h Pressure loss 9.08E-6 0.01 0.04 mbar Velocity (meas. tube) 0.127 5.52 8.697 m/s Measured error Mass*** 14.3 1.5 1.5 % Reynolds No. 9 574 414 858 653 668 ***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in technical documentation. Attention for Flow! Device is used in non-ideal application conditions.
  • 10. Print date: 29.04.2014 12:00 PM Applicator®: 10.16.05 / 133 - 3 / 7 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : LPG-KHX Timestamp: --- Review number: --- Sales order number: Fluid properties sheet Fluid Fluid name Propane (Gas) State Gas Chemical formula CH3-CH2-CH3 Calculation standard NEL Fluid description Medium character Clean Fluid group (PED) Dangerous Fluid (Fluid group 1) Fluid stability Stable Gas mixture Component Fraction 1    Propane (Gas) 100   Mole% 100   Mass% 2    0   Mole% 0   Mass% 3    0   Mole% 0   Mass% 4    0   Mole% 0   Mass% 5    0   Mole% 0   Mass% 6    0   Mole% 0   Mass% 7    0   Mole% 0   Mass% 8    0   Mole% 0   Mass% Basic fluid parameters Tc (Critical temperature) 96.69   °C Pc (Critical pressure) 42.47   bar Rho_c (Critical density) 217   kg/m3 Tm (Melting point) -187.7   °C Tb (Boiling point) -42.11   °C Calculated results Density nom. 4.0131   kg/m3 Molar mass 44.096   kg/kmol Z-factor nom. 0.9649 Viscosity nom. 0.00845   cP Sound velocity nom. 248.7   m/s Thermal capacity nom. 1.742   kJ/(kg*K) Heat conductivity nom. 0.018   W/(m K) Vapor pressure nom. 10.815   bar_a Pressure nom. 1.2   bar_g Temperature nom. 30   °C   Reference values:   Normal conditions (SI): Standard conditions (US): Atmospheric pressure 1.0132   bar_a Density normal 2.0122   kg/m3 Temperature 0   °C Pressure 1.0132   bar_a Atmospheric pressure 1.0132   bar_a Density standard 1.9005   kg/m3 Temperature 59   °F Pressure 14.696   psi_a
  • 11. Print date: 29.04.2014 12:00 PM Applicator®: 10.16.05 / 133 - 4 / 7 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : LPG-KHX Timestamp: --- Review number: --- Sales order number: Installation sheet Flowmeter / Accessories   Extended order code Qty Item Description Extended order code 1 Flowmeter t-mass 65I 65I-20AB 1 Accessory Mounting boss - DK6MB DK6MB-B Installation data : Insertion depth X (scale value) 160.49   mm Insertion tube length 235   mm Pipe inner diameter 20°C 158.3   mm Duct Installation Horizontal Duct internal height   Duct internal width   Wall thickness 5   mm C1 = Height process connection 60   mm C2 = Height sensor connection 46   mm C3 = Height ball valve 0   mm C = Total height of connection 106   mm A= Internal diameter or internal height (duct vertical installation) or internal width (duct horizontal installation) B= Wall thickness C= Height of connection *The Enduser is responsible for the correct selection of the piping. Applicator does not calculate necessary pipe wall thickness according to application data. Endress + Hauser takes no liability for the suitability of the pipe dimensions. Attention for Flow! Device is used in non-ideal application conditions.
  • 12. Print date: 29.04.2014 12:00 PM Applicator®: 10.16.05 / 133 - 5 / 7 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : LPG-KHX Timestamp: --- Review number: --- Sales order number: Tri-Size Sheet General Parameters Fluid Propane (Gas) Ref. Temperature 0 °C State Gas Ref. Pressure 1.013 bar_a Character Clean Atmospheric Pressure 1.0132 bar_a Abrasivity Not abrasive Standard EN/DIN/ISO Fluid Group (PED) Dangerous Fluid (Fluid group 1) Sizing and Calculated Results Next Smaller Size Current Size Next Bigger Size Flow meter t-mass 65I t-mass 65I t-mass 65I Flow Principle Thermal (t-mass) Thermal (t-mass) Thermal (t-mass) Meter Size DN 100 DN 150 DN 200 Process connection* G 1 A ISO 228 / 1.4404 /316L G 1 A ISO 228 / 1.4404 /316L G 1 A ISO 228 / 1.4404 /316L Minimum Flow 7.427 17.108 29.85 Nm3/h Calibrated Flow 742.698 1 710.824 2 985.049 Nm3/h Maximum Flow 1 485.4 3 421.65 5 970.1 Nm3/h Pressure loss at req. Flow min. 6.42E-5 9.08E-6 2.49E-6 mbar Pressure loss at req. Flow nom. 0.11 0.01 4.14E-3 mbar Pressure loss at req. Flow max. 0.27 0.04 0.01 mbar Velocity (meas. tube) at req. Flow min. 0.293 0.127 0.073 m/s Velocity (meas. tube) at req. Flow nom. 12.72 5.52 3.164 m/s Velocity (meas. tube) at req. Flow max. 20.03 8.697 4.985 m/s Meas. error Mass at req. Flow min.*** 6.19 14.3 n.a. % Meas. error Mass at req. Flow nom.*** 1.85 1.5 1.5 % Meas. error Mass at req. Flow max.*** n.a. 1.5 1.5 % Reynolds No. 629 646 414 858 314 070 *The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and assumes no liability for the corrosion resistance of the materials selected here for the application described above. ***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in technical documentation.
  • 13. Print date: 29.04.2014 12:00 PM Applicator®: 10.16.05 / 133 - 6 / 7 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : LPG-KHX Timestamp: --- Review number: --- Sales order number: Chart Sheet Flowmeter : t-mass 65I Flow Principle Thermal (t-mass) Meter Size DN 150 Minimum Flow 17.108   Nm3/h Calibrated Flow 1 710.824   Nm3/h Maximum Flow 3 421.65   Nm3/h ***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in technical documentation.
  • 14. Print date: 29.04.2014 12:00 PM Applicator®: 10.16.05 / 133 - 7 / 7 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : LPG-KHX Timestamp: --- Review number: --- Sales order number: Corrosion Information General Parameters Fluid Propane (Gas) Abrasivity Not abrasive State Gas Character Clean Flow Principle Thermal (t-mass) Interpretation of Data, (M) Material: A: resistant, 0.05 mm/y (0.002 inches/y) B: insufficient resistant, 0.5 mm/y (0.02 inches/y) C: not resistant, 1.3 mm/y (0.05 inches/y) NR: not recommended U: unknown Interpretation of Data, (P) Plastics: A: resistant, 15% vol. Swelling/y; 15% Loss of Tensile Strength/y B: insufficient resistant, 30% vol. Swelling/y; 30% Loss of Tensile Strength/y C: not resistant, 50% vol. Swelling/y; 60% Loss of Tensile Strength/y NR: not recommended U: unknown Temperature Material (Sensor) * minimum30°C nominal : 30°C maximum : 30°C (M) CF3M - A 351 A A A (P) EPDM U U U (M) Alloy C22/2.4602 A A A (P) Kalrez A A A (P) PEEK C C C (P) PVDF A A A (M) Stainless steel 316L/316/1.4404 A A A (P) Viton A A A *The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and assumes no liability for the corrosion resistance of the materials selected here for the application described above.
  • 15. Print date: 29.04.2014 11:05 AM Applicator®: 10.16.05 / 133 - 1 / 6 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : LPG-KK Timestamp: --- Review number: --- Sales order number: Sizing Sheet General Parameters Fluid Propane (Gas) Ref. Temperature 0 °C State Gas Ref. Pressure 1.013 bar_a Character Clean Atmospheric Pressure 1.0132 bar_a Abrasivity Not abrasive Standard EN/DIN/ISO Fluid Group (PED) Dangerous Fluid (Fluid group 1) Operating Conditions minimum nominal maximum Requested Flow 7 80 99 Nm3/h Pressure 1.2 bar_g Temperature 30 °C Density 4.0131 kg/m3 Viscosity 0.00845 cP Z-factor 0.9649 Sound Velocity 248.7 m/s Pressure (min/max) 1.2 1.2 bar_g Temp. (min/max) 30 30 °C Flowmeter : t-mass 65F Flow Principle Thermal (t-mass) Meter Size DN 40 Minimum Flow 1.162   Nm3/h Calibrated Flow 116.23   Nm3/h Maximum Flow 232.46   Nm3/h Material (sensor) * SS 1.4404 / 316L Process connection* PN 40 EN 1092-1 B1 / 1.4404/316L Flange PED category ** : Application is Cat. II   Extended order code Qty Item Description Extended order code 1 Flowmeter t-mass 65F 65F40-AE**GP *The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and assumes no liability for the corrosion resistance of the materials selected here for the application described above. ** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissible pressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.
  • 16. Print date: 29.04.2014 11:05 AM Applicator®: 10.16.05 / 133 - 2 / 6 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : LPG-KK Timestamp: --- Review number: --- Sales order number: Sizing Sheet Sizing and Calculated Results minimum nominal maximum Requested Flow 7 80 99 Nm3/h Pressure loss 4.21E-3 0.45 0.68 mbar Velocity (meas. tube) 0.855 9.773 12.09 m/s Measured error Mass*** 2.49 1.5 1.5 % Reynolds No. 15 469 176 787 218 774 ***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in technical documentation.
  • 17. Print date: 29.04.2014 11:05 AM Applicator®: 10.16.05 / 133 - 3 / 6 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : LPG-KK Timestamp: --- Review number: --- Sales order number: Fluid properties sheet Fluid Fluid name Propane (Gas) State Gas Chemical formula CH3-CH2-CH3 Calculation standard NEL Fluid description Medium character Clean Fluid group (PED) Dangerous Fluid (Fluid group 1) Fluid stability Stable Gas mixture Component Fraction 1    Propane (Gas) 100   Mole% 100   Mass% 2    0   Mole% 0   Mass% 3    0   Mole% 0   Mass% 4    0   Mole% 0   Mass% 5    0   Mole% 0   Mass% 6    0   Mole% 0   Mass% 7    0   Mole% 0   Mass% 8    0   Mole% 0   Mass% Basic fluid parameters Tc (Critical temperature) 96.69   °C Pc (Critical pressure) 42.47   bar Rho_c (Critical density) 217   kg/m3 Tm (Melting point) -187.7   °C Tb (Boiling point) -42.11   °C Calculated results Density nom. 4.0131   kg/m3 Molar mass 44.096   kg/kmol Z-factor nom. 0.9649 Viscosity nom. 0.00845   cP Sound velocity nom. 248.7   m/s Thermal capacity nom. 1.742   kJ/(kg*K) Heat conductivity nom. 0.018   W/(m K) Vapor pressure nom. 10.815   bar_a Pressure nom. 1.2   bar_g Temperature nom. 30   °C   Reference values:   Normal conditions (SI): Standard conditions (US): Atmospheric pressure 1.0132   bar_a Density normal 2.0122   kg/m3 Temperature 0   °C Pressure 1.0132   bar_a Atmospheric pressure 1.0132   bar_a Density standard 1.9005   kg/m3 Temperature 59   °F Pressure 14.696   psi_a
  • 18. Print date: 29.04.2014 11:05 AM Applicator®: 10.16.05 / 133 - 4 / 6 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : LPG-KK Timestamp: --- Review number: --- Sales order number: Tri-Size Sheet General Parameters Fluid Propane (Gas) Ref. Temperature 0 °C State Gas Ref. Pressure 1.013 bar_a Character Clean Atmospheric Pressure 1.0132 bar_a Abrasivity Not abrasive Standard EN/DIN/ISO Fluid Group (PED) Dangerous Fluid (Fluid group 1) Sizing and Calculated Results Next Smaller Size Current Size Next Bigger Size Flow meter t-mass 65F t-mass 65F t-mass 65F Flow Principle Thermal (t-mass) Thermal (t-mass) Thermal (t-mass) Meter Size DN 25 DN 40 DN 50 Process connection* PN 40 EN 1092-1 B1 / 1.4404/316L PN 40 EN 1092-1 B1 / 1.4404/316L PN 40 EN 1092-1 B1 / 1.4404/316L Minimum Flow 0.419 1.162 1.906 Nm3/h Calibrated Flow 41.885 116.23 190.575 Nm3/h Maximum Flow 83.769 232.46 381.151 Nm3/h Pressure loss at req. Flow min. 0.02 4.21E-3 1.46E-3 mbar Pressure loss at req. Flow nom. 3.71 0.45 0.13 mbar Pressure loss at req. Flow max. 5.7 0.68 0.21 mbar Velocity (meas. tube) at req. Flow min. 2.102 0.855 0.513 m/s Velocity (meas. tube) at req. Flow nom. 24.03 9.773 5.861 m/s Velocity (meas. tube) at req. Flow max. 29.73 12.09 7.253 m/s Meas. error Mass at req. Flow min.*** 1.5 2.49 4.08 % Meas. error Mass at req. Flow nom.*** n.a. 1.5 1.5 % Meas. error Mass at req. Flow max.*** n.a. 1.5 1.5 % Reynolds No. 277 185 176 787 136 902 *The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and assumes no liability for the corrosion resistance of the materials selected here for the application described above. ***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in technical documentation.
  • 19. Print date: 29.04.2014 11:05 AM Applicator®: 10.16.05 / 133 - 5 / 6 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : LPG-KK Timestamp: --- Review number: --- Sales order number: Chart Sheet Flowmeter : t-mass 65F Flow Principle Thermal (t-mass) Meter Size DN 40 Minimum Flow 1.162   Nm3/h Calibrated Flow 116.23   Nm3/h Maximum Flow 232.46   Nm3/h ***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in technical documentation.
  • 20. Print date: 29.04.2014 11:05 AM Applicator®: 10.16.05 / 133 - 6 / 6 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : LPG-KK Timestamp: --- Review number: --- Sales order number: Corrosion Information General Parameters Fluid Propane (Gas) Abrasivity Not abrasive State Gas Character Clean Flow Principle Thermal (t-mass) Interpretation of Data, (M) Material: A: resistant, 0.05 mm/y (0.002 inches/y) B: insufficient resistant, 0.5 mm/y (0.02 inches/y) C: not resistant, 1.3 mm/y (0.05 inches/y) NR: not recommended U: unknown Interpretation of Data, (P) Plastics: A: resistant, 15% vol. Swelling/y; 15% Loss of Tensile Strength/y B: insufficient resistant, 30% vol. Swelling/y; 30% Loss of Tensile Strength/y C: not resistant, 50% vol. Swelling/y; 60% Loss of Tensile Strength/y NR: not recommended U: unknown Temperature Material (Sensor) * minimum30°C nominal : 30°C maximum : 30°C (M) CF3M - A 351 A A A (P) EPDM U U U (M) Alloy C22/2.4602 A A A (P) Kalrez A A A (P) PEEK C C C (P) PVDF A A A (M) Stainless steel 316L/316/1.4404 A A A (P) Viton A A A *The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and assumes no liability for the corrosion resistance of the materials selected here for the application described above.
  • 21. Print date: 29.04.2014 11:16 AM Applicator®: 10.16.05 / 133 - 1 / 6 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : LPG-Boiler Timestamp: --- Review number: --- Sales order number: Sizing Sheet General Parameters Fluid Propane (Gas) Ref. Temperature 0 °C State Gas Ref. Pressure 1.013 bar_a Character Clean Atmospheric Pressure 1.0132 bar_a Abrasivity Not abrasive Standard EN/DIN/ISO Fluid Group (PED) Dangerous Fluid (Fluid group 1) Operating Conditions minimum nominal maximum Requested Flow 20 420 448 Nm3/h Pressure 1.2 bar_g Temperature 30 °C Density 4.0131 kg/m3 Viscosity 0.00845 cP Z-factor 0.9649 Sound Velocity 248.7 m/s Pressure (min/max) 1.2 1.2 bar_g Temp. (min/max) 30 30 °C Flowmeter : t-mass 65F Flow Principle Thermal (t-mass) Meter Size DN 80 Minimum Flow 4.48   Nm3/h Calibrated Flow 448.013   Nm3/h Maximum Flow 896.026   Nm3/h Material (sensor) * SS 1.4404 / 316L Process connection* PN 40 EN 1092-1 B1 / 1.4404/316L Flange PED category ** : Application is Cat. II   Extended order code Qty Item Description Extended order code 1 Flowmeter t-mass 65F 65F80-AE**GP *The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and assumes no liability for the corrosion resistance of the materials selected here for the application described above. ** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissible pressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.
  • 22. Print date: 29.04.2014 11:16 AM Applicator®: 10.16.05 / 133 - 2 / 6 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : LPG-Boiler Timestamp: --- Review number: --- Sales order number: Sizing Sheet Sizing and Calculated Results minimum nominal maximum Requested Flow 20 420 448 Nm3/h Pressure loss 1.64E-3 0.52 0.6 mbar Velocity (meas. tube) 0.594 12.46 13.3 m/s Measured error Mass*** 3.36 1.5 1.5 % Reynolds No. 21 784 457 463 487 961 ***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in technical documentation.
  • 23. Print date: 29.04.2014 11:16 AM Applicator®: 10.16.05 / 133 - 3 / 6 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : LPG-Boiler Timestamp: --- Review number: --- Sales order number: Fluid properties sheet Fluid Fluid name Propane (Gas) State Gas Chemical formula CH3-CH2-CH3 Calculation standard NEL Fluid description Medium character Clean Fluid group (PED) Dangerous Fluid (Fluid group 1) Fluid stability Stable Gas mixture Component Fraction 1    Propane (Gas) 100   Mole% 100   Mass% 2    0   Mole% 0   Mass% 3    0   Mole% 0   Mass% 4    0   Mole% 0   Mass% 5    0   Mole% 0   Mass% 6    0   Mole% 0   Mass% 7    0   Mole% 0   Mass% 8    0   Mole% 0   Mass% Basic fluid parameters Tc (Critical temperature) 96.69   °C Pc (Critical pressure) 42.47   bar Rho_c (Critical density) 217   kg/m3 Tm (Melting point) -187.7   °C Tb (Boiling point) -42.11   °C Calculated results Density nom. 4.0131   kg/m3 Molar mass 44.096   kg/kmol Z-factor nom. 0.9649 Viscosity nom. 0.00845   cP Sound velocity nom. 248.7   m/s Thermal capacity nom. 1.742   kJ/(kg*K) Heat conductivity nom. 0.018   W/(m K) Vapor pressure nom. 10.815   bar_a Pressure nom. 1.2   bar_g Temperature nom. 30   °C   Reference values:   Normal conditions (SI): Standard conditions (US): Atmospheric pressure 1.0132   bar_a Density normal 2.0122   kg/m3 Temperature 0   °C Pressure 1.0132   bar_a Atmospheric pressure 1.0132   bar_a Density standard 1.9005   kg/m3 Temperature 59   °F Pressure 14.696   psi_a
  • 24. Print date: 29.04.2014 11:16 AM Applicator®: 10.16.05 / 133 - 4 / 6 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : LPG-Boiler Timestamp: --- Review number: --- Sales order number: Tri-Size Sheet General Parameters Fluid Propane (Gas) Ref. Temperature 0 °C State Gas Ref. Pressure 1.013 bar_a Character Clean Atmospheric Pressure 1.0132 bar_a Abrasivity Not abrasive Standard EN/DIN/ISO Fluid Group (PED) Dangerous Fluid (Fluid group 1) Sizing and Calculated Results Next Smaller Size Current Size Next Bigger Size Flow meter t-mass 65F t-mass 65F t-mass 65F Flow Principle Thermal (t-mass) Thermal (t-mass) Thermal (t-mass) Meter Size DN 50 DN 80 DN 100 Process connection* PN 40 EN 1092-1 B1 / 1.4404/316L PN 40 EN 1092-1 B1 / 1.4404/316L PN 16 EN 1092-1 B1 / 1.4404/316L Minimum Flow 1.906 4.48 7.853 Nm3/h Calibrated Flow 190.575 448.013 785.338 Nm3/h Maximum Flow 381.151 896.026 1 570.68 Nm3/h Pressure loss at req. Flow min. 9.29E-3 1.64E-3 6.5E-4 mbar Pressure loss at req. Flow nom. 3.7 0.52 0.18 mbar Pressure loss at req. Flow max. 4.21 0.6 0.21 mbar Velocity (meas. tube) at req. Flow min. 1.465 0.594 0.369 m/s Velocity (meas. tube) at req. Flow nom. 30.77 12.46 7.755 m/s Velocity (meas. tube) at req. Flow max. 32.82 13.3 8.272 m/s Meas. error Mass at req. Flow min.*** 1.5 3.36 5.89 % Meas. error Mass at req. Flow nom.*** n.a. 1.5 1.5 % Meas. error Mass at req. Flow max.*** n.a. 1.5 1.5 % Reynolds No. 718 738 457 463 360 836 *The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and assumes no liability for the corrosion resistance of the materials selected here for the application described above. ***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in technical documentation.
  • 25. Print date: 29.04.2014 11:16 AM Applicator®: 10.16.05 / 133 - 5 / 6 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : LPG-Boiler Timestamp: --- Review number: --- Sales order number: Chart Sheet Flowmeter : t-mass 65F Flow Principle Thermal (t-mass) Meter Size DN 80 Minimum Flow 4.48   Nm3/h Calibrated Flow 448.013   Nm3/h Maximum Flow 896.026   Nm3/h ***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in technical documentation.
  • 26. Print date: 29.04.2014 11:16 AM Applicator®: 10.16.05 / 133 - 6 / 6 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : LPG-Boiler Timestamp: --- Review number: --- Sales order number: Corrosion Information General Parameters Fluid Propane (Gas) Abrasivity Not abrasive State Gas Character Clean Flow Principle Thermal (t-mass) Interpretation of Data, (M) Material: A: resistant, 0.05 mm/y (0.002 inches/y) B: insufficient resistant, 0.5 mm/y (0.02 inches/y) C: not resistant, 1.3 mm/y (0.05 inches/y) NR: not recommended U: unknown Interpretation of Data, (P) Plastics: A: resistant, 15% vol. Swelling/y; 15% Loss of Tensile Strength/y B: insufficient resistant, 30% vol. Swelling/y; 30% Loss of Tensile Strength/y C: not resistant, 50% vol. Swelling/y; 60% Loss of Tensile Strength/y NR: not recommended U: unknown Temperature Material (Sensor) * minimum30°C nominal : 30°C maximum : 30°C (M) CF3M - A 351 A A A (P) EPDM U U U (M) Alloy C22/2.4602 A A A (P) Kalrez A A A (P) PEEK C C C (P) PVDF A A A (M) Stainless steel 316L/316/1.4404 A A A (P) Viton A A A *The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and assumes no liability for the corrosion resistance of the materials selected here for the application described above.
  • 27. Print date: 29.04.2014 11:09 AM Applicator®: 10.16.05 / 133 - 1 / 6 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : LPG-Canteen Timestamp: --- Review number: --- Sales order number: Sizing Sheet General Parameters Fluid Propane (Gas) Ref. Temperature 0 °C State Gas Ref. Pressure 1.013 bar_a Character Clean Atmospheric Pressure 1.0132 bar_a Abrasivity Not abrasive Standard EN/DIN/ISO Fluid Group (PED) Dangerous Fluid (Fluid group 1) Operating Conditions minimum nominal maximum Requested Flow 7 80 94 Nm3/h Pressure 1.2 bar_g Temperature 30 °C Density 4.0131 kg/m3 Viscosity 0.00845 cP Z-factor 0.9649 Sound Velocity 248.7 m/s Pressure (min/max) 1.2 1.2 bar_g Temp. (min/max) 30 30 °C Flowmeter : t-mass 65F Flow Principle Thermal (t-mass) Meter Size DN 40 Minimum Flow 1.162   Nm3/h Calibrated Flow 116.23   Nm3/h Maximum Flow 232.46   Nm3/h Material (sensor) * SS 1.4404 / 316L Process connection* PN 40 EN 1092-1 B1 / 1.4404/316L Flange PED category ** : Application is Cat. II   Extended order code Qty Item Description Extended order code 1 Flowmeter t-mass 65F 65F40-AE**GP *The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and assumes no liability for the corrosion resistance of the materials selected here for the application described above. ** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissible pressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.
  • 28. Print date: 29.04.2014 11:09 AM Applicator®: 10.16.05 / 133 - 2 / 6 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : LPG-Canteen Timestamp: --- Review number: --- Sales order number: Sizing Sheet Sizing and Calculated Results minimum nominal maximum Requested Flow 7 80 94 Nm3/h Pressure loss 4.21E-3 0.45 0.62 mbar Velocity (meas. tube) 0.855 9.773 11.48 m/s Measured error Mass*** 2.49 1.5 1.5 % Reynolds No. 15 469 176 787 207 725 ***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in technical documentation.
  • 29. Print date: 29.04.2014 11:09 AM Applicator®: 10.16.05 / 133 - 3 / 6 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : LPG-Canteen Timestamp: --- Review number: --- Sales order number: Fluid properties sheet Fluid Fluid name Propane (Gas) State Gas Chemical formula CH3-CH2-CH3 Calculation standard NEL Fluid description Medium character Clean Fluid group (PED) Dangerous Fluid (Fluid group 1) Fluid stability Stable Gas mixture Component Fraction 1    Propane (Gas) 100   Mole% 100   Mass% 2    0   Mole% 0   Mass% 3    0   Mole% 0   Mass% 4    0   Mole% 0   Mass% 5    0   Mole% 0   Mass% 6    0   Mole% 0   Mass% 7    0   Mole% 0   Mass% 8    0   Mole% 0   Mass% Basic fluid parameters Tc (Critical temperature) 96.69   °C Pc (Critical pressure) 42.47   bar Rho_c (Critical density) 217   kg/m3 Tm (Melting point) -187.7   °C Tb (Boiling point) -42.11   °C Calculated results Density nom. 4.0131   kg/m3 Molar mass 44.096   kg/kmol Z-factor nom. 0.9649 Viscosity nom. 0.00845   cP Sound velocity nom. 248.7   m/s Thermal capacity nom. 1.742   kJ/(kg*K) Heat conductivity nom. 0.018   W/(m K) Vapor pressure nom. 10.815   bar_a Pressure nom. 1.2   bar_g Temperature nom. 30   °C   Reference values:   Normal conditions (SI): Standard conditions (US): Atmospheric pressure 1.0132   bar_a Density normal 2.0122   kg/m3 Temperature 0   °C Pressure 1.0132   bar_a Atmospheric pressure 1.0132   bar_a Density standard 1.9005   kg/m3 Temperature 59   °F Pressure 14.696   psi_a
  • 30. Print date: 29.04.2014 11:09 AM Applicator®: 10.16.05 / 133 - 4 / 6 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : LPG-Canteen Timestamp: --- Review number: --- Sales order number: Tri-Size Sheet General Parameters Fluid Propane (Gas) Ref. Temperature 0 °C State Gas Ref. Pressure 1.013 bar_a Character Clean Atmospheric Pressure 1.0132 bar_a Abrasivity Not abrasive Standard EN/DIN/ISO Fluid Group (PED) Dangerous Fluid (Fluid group 1) Sizing and Calculated Results Next Smaller Size Current Size Next Bigger Size Flow meter t-mass 65F t-mass 65F t-mass 65F Flow Principle Thermal (t-mass) Thermal (t-mass) Thermal (t-mass) Meter Size DN 25 DN 40 DN 50 Process connection* PN 40 EN 1092-1 B1 / 1.4404/316L PN 40 EN 1092-1 B1 / 1.4404/316L PN 40 EN 1092-1 B1 / 1.4404/316L Minimum Flow 0.419 1.162 1.906 Nm3/h Calibrated Flow 41.885 116.23 190.575 Nm3/h Maximum Flow 83.769 232.46 381.151 Nm3/h Pressure loss at req. Flow min. 0.02 4.21E-3 1.46E-3 mbar Pressure loss at req. Flow nom. 3.71 0.45 0.13 mbar Pressure loss at req. Flow max. 5.14 0.62 0.19 mbar Velocity (meas. tube) at req. Flow min. 2.102 0.855 0.513 m/s Velocity (meas. tube) at req. Flow nom. 24.03 9.773 5.861 m/s Velocity (meas. tube) at req. Flow max. 28.23 11.48 6.887 m/s Meas. error Mass at req. Flow min.*** 1.5 2.49 4.08 % Meas. error Mass at req. Flow nom.*** n.a. 1.5 1.5 % Meas. error Mass at req. Flow max.*** n.a. 1.5 1.5 % Reynolds No. 277 185 176 787 136 902 *The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and assumes no liability for the corrosion resistance of the materials selected here for the application described above. ***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in technical documentation.
  • 31. Print date: 29.04.2014 11:09 AM Applicator®: 10.16.05 / 133 - 5 / 6 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : LPG-Canteen Timestamp: --- Review number: --- Sales order number: Chart Sheet Flowmeter : t-mass 65F Flow Principle Thermal (t-mass) Meter Size DN 40 Minimum Flow 1.162   Nm3/h Calibrated Flow 116.23   Nm3/h Maximum Flow 232.46   Nm3/h ***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in technical documentation.
  • 32. Print date: 29.04.2014 11:09 AM Applicator®: 10.16.05 / 133 - 6 / 6 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : LPG-Canteen Timestamp: --- Review number: --- Sales order number: Corrosion Information General Parameters Fluid Propane (Gas) Abrasivity Not abrasive State Gas Character Clean Flow Principle Thermal (t-mass) Interpretation of Data, (M) Material: A: resistant, 0.05 mm/y (0.002 inches/y) B: insufficient resistant, 0.5 mm/y (0.02 inches/y) C: not resistant, 1.3 mm/y (0.05 inches/y) NR: not recommended U: unknown Interpretation of Data, (P) Plastics: A: resistant, 15% vol. Swelling/y; 15% Loss of Tensile Strength/y B: insufficient resistant, 30% vol. Swelling/y; 30% Loss of Tensile Strength/y C: not resistant, 50% vol. Swelling/y; 60% Loss of Tensile Strength/y NR: not recommended U: unknown Temperature Material (Sensor) * minimum30°C nominal : 30°C maximum : 30°C (M) CF3M - A 351 A A A (P) EPDM U U U (M) Alloy C22/2.4602 A A A (P) Kalrez A A A (P) PEEK C C C (P) PVDF A A A (M) Stainless steel 316L/316/1.4404 A A A (P) Viton A A A *The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and assumes no liability for the corrosion resistance of the materials selected here for the application described above.
  • 33. Print date: 29.04.2014 11:10 AM Applicator®: 10.16.05 / 133 - 1 / 6 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : LPG-Schaff Timestamp: --- Review number: --- Sales order number: Sizing Sheet General Parameters Fluid Propane (Gas) Ref. Temperature 0 °C State Gas Ref. Pressure 1.013 bar_a Character Clean Atmospheric Pressure 1.0132 bar_a Abrasivity Not abrasive Standard EN/DIN/ISO Fluid Group (PED) Dangerous Fluid (Fluid group 1) Operating Conditions minimum nominal maximum Requested Flow 7 80 94 Nm3/h Pressure 1.2 bar_g Temperature 30 °C Density 4.0131 kg/m3 Viscosity 0.00845 cP Z-factor 0.9649 Sound Velocity 248.7 m/s Pressure (min/max) 1.2 1.2 bar_g Temp. (min/max) 30 30 °C Flowmeter : t-mass 65F Flow Principle Thermal (t-mass) Meter Size DN 40 Minimum Flow 1.162   Nm3/h Calibrated Flow 116.23   Nm3/h Maximum Flow 232.46   Nm3/h Material (sensor) * SS 1.4404 / 316L Process connection* PN 40 EN 1092-1 B1 / 1.4404/316L Flange PED category ** : Application is Cat. II   Extended order code Qty Item Description Extended order code 1 Flowmeter t-mass 65F 65F40-AE**GP *The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and assumes no liability for the corrosion resistance of the materials selected here for the application described above. ** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissible pressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.
  • 34. Print date: 29.04.2014 11:10 AM Applicator®: 10.16.05 / 133 - 2 / 6 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : LPG-Schaff Timestamp: --- Review number: --- Sales order number: Sizing Sheet Sizing and Calculated Results minimum nominal maximum Requested Flow 7 80 94 Nm3/h Pressure loss 4.21E-3 0.45 0.62 mbar Velocity (meas. tube) 0.855 9.773 11.48 m/s Measured error Mass*** 2.49 1.5 1.5 % Reynolds No. 15 469 176 787 207 725 ***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in technical documentation.
  • 35. Print date: 29.04.2014 11:10 AM Applicator®: 10.16.05 / 133 - 3 / 6 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : LPG-Schaff Timestamp: --- Review number: --- Sales order number: Fluid properties sheet Fluid Fluid name Propane (Gas) State Gas Chemical formula CH3-CH2-CH3 Calculation standard NEL Fluid description Medium character Clean Fluid group (PED) Dangerous Fluid (Fluid group 1) Fluid stability Stable Gas mixture Component Fraction 1    Propane (Gas) 100   Mole% 100   Mass% 2    0   Mole% 0   Mass% 3    0   Mole% 0   Mass% 4    0   Mole% 0   Mass% 5    0   Mole% 0   Mass% 6    0   Mole% 0   Mass% 7    0   Mole% 0   Mass% 8    0   Mole% 0   Mass% Basic fluid parameters Tc (Critical temperature) 96.69   °C Pc (Critical pressure) 42.47   bar Rho_c (Critical density) 217   kg/m3 Tm (Melting point) -187.7   °C Tb (Boiling point) -42.11   °C Calculated results Density nom. 4.0131   kg/m3 Molar mass 44.096   kg/kmol Z-factor nom. 0.9649 Viscosity nom. 0.00845   cP Sound velocity nom. 248.7   m/s Thermal capacity nom. 1.742   kJ/(kg*K) Heat conductivity nom. 0.018   W/(m K) Vapor pressure nom. 10.815   bar_a Pressure nom. 1.2   bar_g Temperature nom. 30   °C   Reference values:   Normal conditions (SI): Standard conditions (US): Atmospheric pressure 1.0132   bar_a Density normal 2.0122   kg/m3 Temperature 0   °C Pressure 1.0132   bar_a Atmospheric pressure 1.0132   bar_a Density standard 1.9005   kg/m3 Temperature 59   °F Pressure 14.696   psi_a
  • 36. Print date: 29.04.2014 11:10 AM Applicator®: 10.16.05 / 133 - 4 / 6 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : LPG-Schaff Timestamp: --- Review number: --- Sales order number: Tri-Size Sheet General Parameters Fluid Propane (Gas) Ref. Temperature 0 °C State Gas Ref. Pressure 1.013 bar_a Character Clean Atmospheric Pressure 1.0132 bar_a Abrasivity Not abrasive Standard EN/DIN/ISO Fluid Group (PED) Dangerous Fluid (Fluid group 1) Sizing and Calculated Results Next Smaller Size Current Size Next Bigger Size Flow meter t-mass 65F t-mass 65F t-mass 65F Flow Principle Thermal (t-mass) Thermal (t-mass) Thermal (t-mass) Meter Size DN 25 DN 40 DN 50 Process connection* PN 40 EN 1092-1 B1 / 1.4404/316L PN 40 EN 1092-1 B1 / 1.4404/316L PN 40 EN 1092-1 B1 / 1.4404/316L Minimum Flow 0.419 1.162 1.906 Nm3/h Calibrated Flow 41.885 116.23 190.575 Nm3/h Maximum Flow 83.769 232.46 381.151 Nm3/h Pressure loss at req. Flow min. 0.02 4.21E-3 1.46E-3 mbar Pressure loss at req. Flow nom. 3.71 0.45 0.13 mbar Pressure loss at req. Flow max. 5.14 0.62 0.19 mbar Velocity (meas. tube) at req. Flow min. 2.102 0.855 0.513 m/s Velocity (meas. tube) at req. Flow nom. 24.03 9.773 5.861 m/s Velocity (meas. tube) at req. Flow max. 28.23 11.48 6.887 m/s Meas. error Mass at req. Flow min.*** 1.5 2.49 4.08 % Meas. error Mass at req. Flow nom.*** n.a. 1.5 1.5 % Meas. error Mass at req. Flow max.*** n.a. 1.5 1.5 % Reynolds No. 277 185 176 787 136 902 *The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and assumes no liability for the corrosion resistance of the materials selected here for the application described above. ***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in technical documentation.
  • 37. Print date: 29.04.2014 11:10 AM Applicator®: 10.16.05 / 133 - 5 / 6 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : LPG-Schaff Timestamp: --- Review number: --- Sales order number: Chart Sheet Flowmeter : t-mass 65F Flow Principle Thermal (t-mass) Meter Size DN 40 Minimum Flow 1.162   Nm3/h Calibrated Flow 116.23   Nm3/h Maximum Flow 232.46   Nm3/h ***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in technical documentation.
  • 38. Print date: 29.04.2014 11:10 AM Applicator®: 10.16.05 / 133 - 6 / 6 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : LPG-Schaff Timestamp: --- Review number: --- Sales order number: Corrosion Information General Parameters Fluid Propane (Gas) Abrasivity Not abrasive State Gas Character Clean Flow Principle Thermal (t-mass) Interpretation of Data, (M) Material: A: resistant, 0.05 mm/y (0.002 inches/y) B: insufficient resistant, 0.5 mm/y (0.02 inches/y) C: not resistant, 1.3 mm/y (0.05 inches/y) NR: not recommended U: unknown Interpretation of Data, (P) Plastics: A: resistant, 15% vol. Swelling/y; 15% Loss of Tensile Strength/y B: insufficient resistant, 30% vol. Swelling/y; 30% Loss of Tensile Strength/y C: not resistant, 50% vol. Swelling/y; 60% Loss of Tensile Strength/y NR: not recommended U: unknown Temperature Material (Sensor) * minimum30°C nominal : 30°C maximum : 30°C (M) CF3M - A 351 A A A (P) EPDM U U U (M) Alloy C22/2.4602 A A A (P) Kalrez A A A (P) PEEK C C C (P) PVDF A A A (M) Stainless steel 316L/316/1.4404 A A A (P) Viton A A A *The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and assumes no liability for the corrosion resistance of the materials selected here for the application described above.
  • 39. Print date: 29.04.2014 08:56 AM Applicator®: 10.16.05 / 133 - 1 / 7 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : NG-Main Timestamp: --- Review number: --- Sales order number: Sizing Sheet General Parameters Fluid Natural Gas Ref. Temperature 0 °C State Gas Ref. Pressure 1.013 bar_a Character Clean Atmospheric Pressure 1.0132 bar_a Abrasivity Not abrasive Standard EN/DIN/ISO Fluid Group (PED) Dangerous Fluid (Fluid group 1) Operating Conditions minimum nominal maximum Requested Flow 50 2 100 2 300 Nm3/h Pressure 1.6 bar_g Temperature 30 °C Density 1.7929 kg/m3 Viscosity 0.01146 cP Z-factor 0.9955 Sound Velocity 433.5 m/s Pressure (min/max) 1.6 1.6 bar_g Temp. (min/max) 30 30 °C Flowmeter : t-mass 65I Flow Principle Thermal (t-mass) Meter Size DN 150 Minimum Flow 37.217   Nm3/h Calibrated Flow 3 721.665   Nm3/h Maximum Flow 7 443.33   Nm3/h Material (sensor) * SS 1.4404 / 316L Process connection* G 1 A ISO 228 / 1.4404 /316L Thread PED category ** : Application meets PED (Art.3.3)   Extended order code Qty Item Description Extended order code 1 Flowmeter t-mass 65I 65I-20AB 1 Accessory Mounting boss - DK6MB DK6MB-B *The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and assumes no liability for the corrosion resistance of the materials selected here for the application described above. ** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissible pressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.
  • 40. Print date: 29.04.2014 08:56 AM Applicator®: 10.16.05 / 133 - 2 / 7 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : NG-Main Timestamp: --- Review number: --- Sales order number: Sizing Sheet Sizing and Calculated Results minimum nominal maximum Requested Flow 50 2 100 2 300 Nm3/h Pressure loss 2.33E-5 0.03 0.04 mbar Velocity (meas. tube) 0.303 12.73 13.94 m/s Measured error Mass*** 11.2 1.5 1.5 % Reynolds No. 7 504 315 151 345 165 ***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in technical documentation. Attention for Flow! Device is used in non-ideal application conditions.
  • 41. Print date: 29.04.2014 08:56 AM Applicator®: 10.16.05 / 133 - 3 / 7 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : NG-Main Timestamp: --- Review number: --- Sales order number: Fluid properties sheet Fluid Fluid name Natural Gas State Gas Chemical formula NASA-Langley Calculation standard NEL Fluid description Medium character Clean Fluid group (PED) Dangerous Fluid (Fluid group 1) Fluid stability Stable Gas mixture Component Fraction 1    Nitrogen (Gas) 2.8   Mole% 4.54   Mass% 2    Carbon dioxide (Gas) 0.21   Mole% 0.54   Mass% 3    Methane (Gas) 91.82   Mole% 85.5   Mass% 4    Ethane (Gas) 4.85   Mole% 8.53   Mass% 5    Propane (Gas) 0.26   Mole% 0.68   Mass% 6    n-Butane (Gas) 0.06   Mole% 0.21   Mass% 7    0   Mole% 0   Mass% 8    0   Mole% 0   Mass% Basic fluid parameters Tc (Critical temperature) -77.57   °C Pc (Critical pressure) 46.1041   bar Rho_c (Critical density) 168.8   kg/m3 Tm (Melting point) n.a.   °C Tb (Boiling point) n.a.   °C Calculated results Density nom. 1.7929   kg/m3 Molar mass 17.214   kg/kmol Z-factor nom. 0.9955 Viscosity nom. 0.01146   cP Sound velocity nom. 433.5   m/s Thermal capacity nom. 2.153   kJ/(kg*K) Heat conductivity nom. 0.034   W/(m K) Vapor pressure nom.   bar_a Pressure nom. 1.6   bar_g Temperature nom. 30   °C   Reference values:   Normal conditions (SI): Standard conditions (US): Atmospheric pressure 1.0132   bar_a Density normal 0.77   kg/m3 Temperature 0   °C Pressure 1.0132   bar_a Atmospheric pressure 1.0132   bar_a Density standard 0.7296   kg/m3 Temperature 59   °F Pressure 14.696   psi_a
  • 42. Print date: 29.04.2014 08:56 AM Applicator®: 10.16.05 / 133 - 4 / 7 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : NG-Main Timestamp: --- Review number: --- Sales order number: Installation sheet Flowmeter / Accessories   Extended order code Qty Item Description Extended order code 1 Flowmeter t-mass 65I 65I-20AB 1 Accessory Mounting boss - DK6MB DK6MB-B Installation data : Insertion depth X (scale value) 160.49   mm Insertion tube length 235   mm Pipe inner diameter 20°C 158.3   mm Duct Installation Horizontal Duct internal height   Duct internal width   Wall thickness 5   mm C1 = Height process connection 60   mm C2 = Height sensor connection 46   mm C3 = Height ball valve 0   mm C = Total height of connection 106   mm A= Internal diameter or internal height (duct vertical installation) or internal width (duct horizontal installation) B= Wall thickness C= Height of connection *The Enduser is responsible for the correct selection of the piping. Applicator does not calculate necessary pipe wall thickness according to application data. Endress + Hauser takes no liability for the suitability of the pipe dimensions. Attention for Flow! Device is used in non-ideal application conditions.
  • 43. Print date: 29.04.2014 08:56 AM Applicator®: 10.16.05 / 133 - 5 / 7 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : NG-Main Timestamp: --- Review number: --- Sales order number: Tri-Size Sheet General Parameters Fluid Natural Gas Ref. Temperature 0 °C State Gas Ref. Pressure 1.013 bar_a Character Clean Atmospheric Pressure 1.0132 bar_a Abrasivity Not abrasive Standard EN/DIN/ISO Fluid Group (PED) Dangerous Fluid (Fluid group 1) Sizing and Calculated Results Next Smaller Size Current Size Next Bigger Size Flow meter t-mass 65I t-mass 65I t-mass 65I Flow Principle Thermal (t-mass) Thermal (t-mass) Thermal (t-mass) Meter Size DN 100 DN 150 DN 200 Process connection* G 1 A ISO 228 / 1.4404 /316L G 1 A ISO 228 / 1.4404 /316L G 1 A ISO 228 / 1.4404 /316L Minimum Flow 16.156 37.217 64.936 Nm3/h Calibrated Flow 1 615.638 3 721.665 6 493.57 Nm3/h Maximum Flow 3 231.28 7 443.33 12 987.1 Nm3/h Pressure loss at req. Flow min. 1.67E-4 2.33E-5 6.6E-6 mbar Pressure loss at req. Flow nom. 0.26 0.03 9.66E-3 mbar Pressure loss at req. Flow max. 0.31 0.04 0.01 mbar Velocity (meas. tube) at req. Flow min. 0.698 0.303 0.174 m/s Velocity (meas. tube) at req. Flow nom. 29.32 12.73 7.295 m/s Velocity (meas. tube) at req. Flow max. 32.11 13.94 7.99 m/s Meas. error Mass at req. Flow min.*** 4.85 11.2 n.a. % Meas. error Mass at req. Flow nom.*** 3.6 1.5 1.5 % Meas. error Mass at req. Flow max.*** 4.47 1.5 1.5 % Reynolds No. 478 316 315 151 238 586 *The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and assumes no liability for the corrosion resistance of the materials selected here for the application described above. ***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in technical documentation.
  • 44. Print date: 29.04.2014 08:56 AM Applicator®: 10.16.05 / 133 - 6 / 7 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : NG-Main Timestamp: --- Review number: --- Sales order number: Chart Sheet Flowmeter : t-mass 65I Flow Principle Thermal (t-mass) Meter Size DN 150 Minimum Flow 37.217   Nm3/h Calibrated Flow 3 721.665   Nm3/h Maximum Flow 7 443.33   Nm3/h ***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in technical documentation.
  • 45. Print date: 29.04.2014 08:56 AM Applicator®: 10.16.05 / 133 - 7 / 7 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : NG-Main Timestamp: --- Review number: --- Sales order number: Corrosion Information General Parameters Fluid Natural Gas Abrasivity Not abrasive State Gas Character Clean Flow Principle Thermal (t-mass) Interpretation of Data, (M) Material: A: resistant, 0.05 mm/y (0.002 inches/y) B: insufficient resistant, 0.5 mm/y (0.02 inches/y) C: not resistant, 1.3 mm/y (0.05 inches/y) NR: not recommended U: unknown Interpretation of Data, (P) Plastics: A: resistant, 15% vol. Swelling/y; 15% Loss of Tensile Strength/y B: insufficient resistant, 30% vol. Swelling/y; 30% Loss of Tensile Strength/y C: not resistant, 50% vol. Swelling/y; 60% Loss of Tensile Strength/y NR: not recommended U: unknown Temperature Material (Sensor) * minimum30°C nominal : 30°C maximum : 30°C *The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and assumes no liability for the corrosion resistance of the materials selected here for the application described above.
  • 46. Print date: 29.04.2014 09:18 AM Applicator®: 10.16.05 / 133 - 1 / 6 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : NG-KHX Timestamp: --- Review number: --- Sales order number: Sizing Sheet General Parameters Fluid Natural Gas Ref. Temperature 0 °C State Gas Ref. Pressure 1.013 bar_a Character Clean Atmospheric Pressure 1.0132 bar_a Abrasivity Not abrasive Standard EN/DIN/ISO Fluid Group (PED) Dangerous Fluid (Fluid group 1) Operating Conditions minimum nominal maximum Requested Flow 84 1 050 1 150 Nm3/h Pressure 1.6 bar_g Temperature 30 °C Density 1.7929 kg/m3 Viscosity 0.01146 cP Z-factor 0.9955 Sound Velocity 433.5 m/s Pressure (min/max) 1.6 1.6 bar_g Temp. (min/max) 30 30 °C Flowmeter : t-mass 65F Flow Principle Thermal (t-mass) Meter Size DN 100 Minimum Flow 17.084   Nm3/h Calibrated Flow 1 708.397   Nm3/h Maximum Flow 3 416.79   Nm3/h Material (sensor) * SS 1.4404 / 316L Process connection* PN 16 EN 1092-1 B1 / 1.4404/316L Flange PED category ** : Application is Cat. II   Extended order code Qty Item Description Extended order code 1 Flowmeter t-mass 65F 65F1H-AB**GP *The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and assumes no liability for the corrosion resistance of the materials selected here for the application described above. ** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissible pressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.
  • 47. Print date: 29.04.2014 09:18 AM Applicator®: 10.16.05 / 133 - 2 / 6 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : NG-KHX Timestamp: --- Review number: --- Sales order number: Sizing Sheet Sizing and Calculated Results minimum nominal maximum Requested Flow 84 1 050 1 150 Nm3/h Pressure loss 3.6E-3 0.39 0.47 mbar Velocity (meas. tube) 1.328 16.61 18.19 m/s Measured error Mass*** 3.05 1.5 1.5 % Reynolds No. 20 363 254 533 278 774 ***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in technical documentation.
  • 48. Print date: 29.04.2014 09:18 AM Applicator®: 10.16.05 / 133 - 3 / 6 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : NG-KHX Timestamp: --- Review number: --- Sales order number: Fluid properties sheet Fluid Fluid name Natural Gas State Gas Chemical formula NASA-Langley Calculation standard NEL Fluid description Medium character Clean Fluid group (PED) Dangerous Fluid (Fluid group 1) Fluid stability Stable Gas mixture Component Fraction 1    Nitrogen (Gas) 2.8   Mole% 4.54   Mass% 2    Carbon dioxide (Gas) 0.21   Mole% 0.54   Mass% 3    Methane (Gas) 91.82   Mole% 85.5   Mass% 4    Ethane (Gas) 4.85   Mole% 8.53   Mass% 5    Propane (Gas) 0.26   Mole% 0.68   Mass% 6    n-Butane (Gas) 0.06   Mole% 0.21   Mass% 7    0   Mole% 0   Mass% 8    0   Mole% 0   Mass% Basic fluid parameters Tc (Critical temperature) -77.57   °C Pc (Critical pressure) 46.1041   bar Rho_c (Critical density) 168.8   kg/m3 Tm (Melting point) n.a.   °C Tb (Boiling point) n.a.   °C Calculated results Density nom. 1.7929   kg/m3 Molar mass 17.214   kg/kmol Z-factor nom. 0.9955 Viscosity nom. 0.01146   cP Sound velocity nom. 433.5   m/s Thermal capacity nom. 2.153   kJ/(kg*K) Heat conductivity nom. 0.034   W/(m K) Vapor pressure nom.   bar_a Pressure nom. 1.6   bar_g Temperature nom. 30   °C   Reference values:   Normal conditions (SI): Standard conditions (US): Atmospheric pressure 1.0132   bar_a Density normal 0.77   kg/m3 Temperature 0   °C Pressure 1.0132   bar_a Atmospheric pressure 1.0132   bar_a Density standard 0.7296   kg/m3 Temperature 59   °F Pressure 14.696   psi_a
  • 49. Print date: 29.04.2014 09:18 AM Applicator®: 10.16.05 / 133 - 4 / 6 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : NG-KHX Timestamp: --- Review number: --- Sales order number: Tri-Size Sheet General Parameters Fluid Natural Gas Ref. Temperature 0 °C State Gas Ref. Pressure 1.013 bar_a Character Clean Atmospheric Pressure 1.0132 bar_a Abrasivity Not abrasive Standard EN/DIN/ISO Fluid Group (PED) Dangerous Fluid (Fluid group 1) Sizing and Calculated Results Next Smaller Size Current Size Next Bigger Size Flow meter t-mass 65F t-mass 65F Flow Principle Thermal (t-mass) Thermal (t-mass) Meter Size DN 80 DN 100 Process connection* PN 40 EN 1092-1 B1 / 1.4404/316L PN 16 EN 1092-1 B1 / 1.4404/316L Minimum Flow 9.746 17.084 Nm3/h Calibrated Flow 974.591 1 708.397 Nm3/h Maximum Flow 1 949.18 3 416.79 Nm3/h Pressure loss at req. Flow min. 9.13E-3 3.6E-3 mbar Pressure loss at req. Flow nom. 1.09 0.39 mbar Pressure loss at req. Flow max. 1.31 0.47 mbar Velocity (meas. tube) at req. Flow min. 2.135 1.328 m/s Velocity (meas. tube) at req. Flow nom. 26.69 16.61 m/s Velocity (meas. tube) at req. Flow max. 29.23 18.19 m/s Meas. error Mass at req. Flow min.*** 1.74 3.05 % Meas. error Mass at req. Flow nom.*** 2.04 1.5 % Meas. error Mass at req. Flow max.*** 2.76 1.5 % Reynolds No. 322 693 254 533 *The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and assumes no liability for the corrosion resistance of the materials selected here for the application described above. ***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in technical documentation.
  • 50. Print date: 29.04.2014 09:18 AM Applicator®: 10.16.05 / 133 - 5 / 6 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : NG-KHX Timestamp: --- Review number: --- Sales order number: Chart Sheet Flowmeter : t-mass 65F Flow Principle Thermal (t-mass) Meter Size DN 100 Minimum Flow 17.084   Nm3/h Calibrated Flow 1 708.397   Nm3/h Maximum Flow 3 416.79   Nm3/h ***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in technical documentation.
  • 51. Print date: 29.04.2014 09:18 AM Applicator®: 10.16.05 / 133 - 6 / 6 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : NG-KHX Timestamp: --- Review number: --- Sales order number: Corrosion Information General Parameters Fluid Natural Gas Abrasivity Not abrasive State Gas Character Clean Flow Principle Thermal (t-mass) Interpretation of Data, (M) Material: A: resistant, 0.05 mm/y (0.002 inches/y) B: insufficient resistant, 0.5 mm/y (0.02 inches/y) C: not resistant, 1.3 mm/y (0.05 inches/y) NR: not recommended U: unknown Interpretation of Data, (P) Plastics: A: resistant, 15% vol. Swelling/y; 15% Loss of Tensile Strength/y B: insufficient resistant, 30% vol. Swelling/y; 30% Loss of Tensile Strength/y C: not resistant, 50% vol. Swelling/y; 60% Loss of Tensile Strength/y NR: not recommended U: unknown Temperature Material (Sensor) * minimum30°C nominal : 30°C maximum : 30°C *The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and assumes no liability for the corrosion resistance of the materials selected here for the application described above.
  • 52. Print date: 29.04.2014 09:22 AM Applicator®: 10.16.05 / 133 - 1 / 6 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : NG-Gas Genset Timestamp: --- Review number: --- Sales order number: Sizing Sheet General Parameters Fluid Natural Gas Ref. Temperature 0 °C State Gas Ref. Pressure 1.013 bar_a Character Clean Atmospheric Pressure 1.0132 bar_a Abrasivity Not abrasive Standard EN/DIN/ISO Fluid Group (PED) Dangerous Fluid (Fluid group 1) Operating Conditions minimum nominal maximum Requested Flow 50 650 700 Nm3/h Pressure 1.6 bar_g Temperature 30 °C Density 1.7929 kg/m3 Viscosity 0.01146 cP Z-factor 0.9955 Sound Velocity 433.5 m/s Pressure (min/max) 1.6 1.6 bar_g Temp. (min/max) 30 30 °C Flowmeter : t-mass 65F Flow Principle Thermal (t-mass) Meter Size DN 80 Minimum Flow 9.746   Nm3/h Calibrated Flow 974.591   Nm3/h Maximum Flow 1 949.18   Nm3/h Material (sensor) * SS 1.4404 / 316L Process connection* PN 40 EN 1092-1 B1 / 1.4404/316L Flange PED category ** : Application is Cat. II   Extended order code Qty Item Description Extended order code 1 Flowmeter t-mass 65F 65F80-AE**GP *The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and assumes no liability for the corrosion resistance of the materials selected here for the application described above. ** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissible pressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.
  • 53. Print date: 29.04.2014 09:22 AM Applicator®: 10.16.05 / 133 - 2 / 6 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : NG-Gas Genset Timestamp: --- Review number: --- Sales order number: Sizing Sheet Sizing and Calculated Results minimum nominal maximum Requested Flow 50 650 700 Nm3/h Pressure loss 3.68E-3 0.42 0.49 mbar Velocity (meas. tube) 1.271 16.52 17.79 m/s Measured error Mass*** 2.92 1.5 1.5 % Reynolds No. 15 366 199 763 215 129 ***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in technical documentation.
  • 54. Print date: 29.04.2014 09:22 AM Applicator®: 10.16.05 / 133 - 3 / 6 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : NG-Gas Genset Timestamp: --- Review number: --- Sales order number: Fluid properties sheet Fluid Fluid name Natural Gas State Gas Chemical formula NASA-Langley Calculation standard NEL Fluid description Medium character Clean Fluid group (PED) Dangerous Fluid (Fluid group 1) Fluid stability Stable Gas mixture Component Fraction 1    Nitrogen (Gas) 2.8   Mole% 4.54   Mass% 2    Carbon dioxide (Gas) 0.21   Mole% 0.54   Mass% 3    Methane (Gas) 91.82   Mole% 85.5   Mass% 4    Ethane (Gas) 4.85   Mole% 8.53   Mass% 5    Propane (Gas) 0.26   Mole% 0.68   Mass% 6    n-Butane (Gas) 0.06   Mole% 0.21   Mass% 7    0   Mole% 0   Mass% 8    0   Mole% 0   Mass% Basic fluid parameters Tc (Critical temperature) -77.57   °C Pc (Critical pressure) 46.1041   bar Rho_c (Critical density) 168.8   kg/m3 Tm (Melting point) n.a.   °C Tb (Boiling point) n.a.   °C Calculated results Density nom. 1.7929   kg/m3 Molar mass 17.214   kg/kmol Z-factor nom. 0.9955 Viscosity nom. 0.01146   cP Sound velocity nom. 433.5   m/s Thermal capacity nom. 2.153   kJ/(kg*K) Heat conductivity nom. 0.034   W/(m K) Vapor pressure nom.   bar_a Pressure nom. 1.6   bar_g Temperature nom. 30   °C   Reference values:   Normal conditions (SI): Standard conditions (US): Atmospheric pressure 1.0132   bar_a Density normal 0.77   kg/m3 Temperature 0   °C Pressure 1.0132   bar_a Atmospheric pressure 1.0132   bar_a Density standard 0.7296   kg/m3 Temperature 59   °F Pressure 14.696   psi_a
  • 55. Print date: 29.04.2014 09:22 AM Applicator®: 10.16.05 / 133 - 4 / 6 -   Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI). Applicator Sizing - Flow Project : Instruments Add on BMS Customer: Pepsico C.Project No.: WNV_00234 Contact person: Muhammad Sarfraz Phone: +92 332 8449027 Fax: +92 42 35820830 eMail: sarfraz@wattnvolt.com.pk TAG : NG-Gas Genset Timestamp: --- Review number: --- Sales order number: Tri-Size Sheet General Parameters Fluid Natural Gas Ref. Temperature 0 °C State Gas Ref. Pressure 1.013 bar_a Character Clean Atmospheric Pressure 1.0132 bar_a Abrasivity Not abrasive Standard EN/DIN/ISO Fluid Group (PED) Dangerous Fluid (Fluid group 1) Sizing and Calculated Results Next Smaller Size Current Size Next Bigger Size Flow meter t-mass 65F t-mass 65F t-mass 65F Flow Principle Thermal (t-mass) Thermal (t-mass) Thermal (t-mass) Meter Size DN 50 DN 80 DN 100 Process connection* PN 40 EN 1092-1 B1 / 1.4404/316L PN 40 EN 1092-1 B1 / 1.4404/316L PN 16 EN 1092-1 B1 / 1.4404/316L Minimum Flow 4.146 9.746 17.084 Nm3/h Calibrated Flow 414.571 974.591 1 708.397 Nm3/h Maximum Flow 829.142 1 949.18 3 416.79 Nm3/h Pressure loss at req. Flow min. 0.02 3.68E-3 1.45E-3 mbar Pressure loss at req. Flow nom. 2.93 0.42 0.15 mbar Pressure loss at req. Flow max. 3.39 0.49 0.18 mbar Velocity (meas. tube) at req. Flow min. 3.137 1.271 0.791 m/s Velocity (meas. tube) at req. Flow nom. 40.79 16.52 10.28 m/s Velocity (meas. tube) at req. Flow max. 43.92 17.79 11.07 m/s Meas. error Mass at req. Flow min.*** 1.5 2.92 5.13 % Meas. error Mass at req. Flow nom.*** n.a. 1.5 1.5 % Meas. error Mass at req. Flow max.*** n.a. 1.5 1.5 % Reynolds No. 313 855 199 763 157 568 *The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and assumes no liability for the corrosion resistance of the materials selected here for the application described above. ***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in technical documentation.