- 7. 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0
Tt 58.8 79.0 91.7 101.1 108.7 115.1 120.6 125.4 129.8 133.8
AF 30% 30% 30% 30% 30% 30% 30% 30% 30% 30%
VF 70% 70% 70% 70% 70% 70% 70% 70% 70% 70%
AF/VF 43% 43% 43% 43% 43% 43% 43% 43% 43% 43%
Ma 29 29 29 29 29 29 29 29 29 29
Mv 18 18 18 18 18 18 18 18 18 18
Pa 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.1
Pv 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 3.9
Tv 52.3 72.0 84.3 93.4 100.7 106.9 112.2 116.9 121.1 125.0
Tt - Tv 6.5 7.1 7.5 7.7 8.0 8.2 8.4 8.5 8.7 8.8
Total Pressure Pt, in.HgA
- 14. 0.000
0.050
0.100
0.150
0.200
0.250
0.500 1.000 1.500 2.000 2.500 3.000 3.500 4.000 4.500 5.000
PARTIAL PRESSURE OF VAPOR, IN.HGA
PARTIALPRESSUREOFAIR,IN.HGA
0.00%
1.00%
2.00%
3.00%
4.00%
5.00%
6.00%
7.00%
8.00%
9.00%
10.00%
11.00%
12.00%
13.00%
14.00%
15.00%
16.00%
17.00%
18.00%
19.00%
20.00%
21.00%
22.00%
AIRFRACTION,%
7 PPB 14 PPB 21 PPB 28 PPB 35 PPB 42 PPB
- 15. 0
5
10
15
20
25
30
35
40
45
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0
CONDENSATE SUBCOOLING, F
DO,PPB
1.0 IN.HGA 1.5 IN.HGA 2.0 IN.HGA 2.5 IN.HGA 3.0 IN.HGA 3.5 IN.HGA 4.0 IN.HGA
4.5 IN.HGA 5.0 IN.HGA