SlideShare a Scribd company logo
1 of 8
Download to read offline
International Journal of Electrical and Computer Engineering (IJECE)
Vol. 8, No. 2, April 2018, pp. 880~887
ISSN: 2088-8708, DOI: 10.11591/ijece.v8i2.pp880-887  880
Journal homepage: http://iaescore.com/journals/index.php/IJECE
Comparative Analysis of Power Quality Indices for Different
Lighting Techniogies in Public Lightning
Jurica Perko1
, Srete Nikolovski2
, Ljubomir Majdandžić3
1
Regional Energy Agency North, Koprivnica, Croatia
2
Faculty of Electrical Engineering, Computer Science and Information Technology, University of Osijek, Croatia
3
Environmental Protections and Energy Efficiency Fund, Zagreb, Croati
Article Info ABSTRACT
Article history:
Received Oct 25, 2017
Revised Jan 4, 2018
Accepted Jan 18, 2018
As with any other product, having electricity of a certain quality is very
important for consumers. Its quality has become the key feature that can be
disturbed by loads based on power electronic devices. Electricity producers
are striving to provide reliable and quality electricity supply to consumers.
Public lighting systems that are based on LED lighting technology can
potentially positively or negatively affect the power quality because they
contain power electronics components in LED drivers. Because of that, two
7-day measurements were conducted on the same public lighting branch but
with different lighting technologies (high pressure sodium, known as HPS
and LED technology). Results of the measurements were analysed and
compared. By analysing the results, other problems were also identified by
using LED lighting technology. These problems are addressed in the
conclusion of the paper.
Keyword:
EN 50160 norm
High pressure sodium
Inrush current
LED lighting
Power quality
Public lighting system Copyright © 2018 Institute of Advanced Engineering and Science.
All rights reserved.
Corresponding Author:
Srete Nikolovski,
Departement of Power Engineering,
Faculty of Electrical Engineering Computing and Information Technology,
University of Osijek,
K. Trpimira 2B, 31000 Osijek, Croatia.
Email: srete.nikolovski@etfos.hr
1. INTRODUCTION
In the recent period, electricity has started to be considered a product as any other, and its quality
has become a very important feature for its consumers. A major problem in power quality is created by
consumers based on power electronic devices because they draw non-linear current, which results in voltage
distortion generation. The first step in solving this problem is measuring and analysing power quality. Power
quality standard EN 50160 gives quantitative requirements for voltage in normal conditions. Its purpose is to
describe voltage characteristics in terms of [1]: frequency, waveform, symmetry, magnitude.
Measurement of power quality according to the standard EN 50160 requires specialized instruments
and measuring methods which enables continuous monitoring of the following parameters [2], [3], frequency,
supply voltage. total harmonic distortion. supply voltage unbalance, flickers, mains signalling voltage. In [3]
is presented a technical and economic study of the solar powered street lighting system of a municipality in
the south of Morocco. The state of the conventional street lighting system is compared with PV-based
lighting.
Power quality parameters, statistical evaluation and compliance limits are given in some papers such
as [4]. The voltage flickers as voltage quality problem in industrial sector are presented in [5]. The use of
high brightness LEDs has become increasingly accepted as light sources in mainstream vehicles and is
presented in [6].
Int J Elec & Comp Eng ISSN: 2088-8708 
Comparative Analysis of Power Quality Indices for Different Lighting Techniogies in …. (Jurica Perko)
881
2. POWER QUALITY INDICES
Power quality parameters, statistical evaluation and compliance limits are given in below in Table 1
Table 1. Supply voltage parameters according to EN 50160
Supply voltage parameter Statistical levels Compliance limit
Power frequency 95 % of the time in 1 week 50 Hz ± 1 %
100 % of the time in 1 week 50 Hz + 4 % to - 6 %
Supply voltage variations Supply voltage variations
95 % of the
time in 1 week
Flickers 95 % of the time in 1 week ≤ 1
Supply voltage unbalance 95 % of the time in 1 week < 2 %
Individual harmonic voltages 95 % of the time in 1 week See Table 2
Total harmonic distortion 95 % of the time in 1 week < 8 %
Mains signalling voltage 95 % of the time in 1 week See Figure 1
Maximal values of odd individual harmonics in percent of nominal voltage are shown in Table 2.
Table 2. Values of individual harmonic voltages according to EN 50160
Odd harmonics not multiples of 3 Odd harmonics multiples of 3
Order Uh in % of Un Order Uh in % of Un
5 6.0 3 5.0
7 5.0 9 1.5
11 3.5 15 0.5
13 3.0 21 0.5
17 2.0
19 1.5
23 1.5
25 1.5
Also, the presence of mains signalling voltages was recorded in power quality measurements
because the Croatian national energy company manages the public lighting system through the power line
communication method. Due to this, there are limitations on voltage levels of signal frequencies in percent of
Uc used in public low voltage distribution networks.
Figure 1. Voltage levels of signal frequencies in low voltage networks
 ISSN: 2088-8708
Int J Elec & Comp Eng, Vol. 8, No. 2, April 2018 : 880 – 887
882
3. MEASUREMENT OF POWER QUALITY ON PUBLIC LIGHTING BRANCH
Measurements are conducted according to the standard EN 50160 with class A measuring device in
7 days’ period. The measuring device is a universal tool for power quality analysis and detection of disorder
in low and medium voltage distribution network. Specifications of class A three phase power quality
measuring device are shown in Table 3 below.
Table 3. Specification of measuring device
IEC 61000-4-30 compliance Class A
Voltage 
Current 
Frequency 
Dips and swells 
Harmonics 
Power and energy 
Energy loss calculator 
Unbalance 
Inrush 
Power wave 
Flicker 
Transients 
Mains signalling 
Power inverter efficiency 
Measurement of power quality is conducted in the same public lighting cabinet on the same branch
for both technologies; LED and HPS. Measurements were conducted over a 7-day period, and the figure
below shows the point of measurement in relation to the transformer station as shown in Figure 2.
Figure 2. Measurement point in relation with transformer station
Loads and measurement periods for both cases High Pressure Sodium (HPS) and Ligh-Emitting
Diode (LED) technology are shown in Table 4.
Table 4. Loads and measurement periods for HPS and LED technology
Lighting technology Number of lamps
Lamp power
[W]
Total lamp power
[W]
Measurement period
HPS 10 189 1,890 7 February 2017 – 14 February 2017
LED 10 17 170 10 March 2017 – 17 March 2017
Int J Elec & Comp Eng ISSN: 2088-8708 
Comparative Analysis of Power Quality Indices for Different Lighting Techniogies in …. (Jurica Perko)
883
4. RESULTS OF POWER QUALITY MEASUREMENTS ON PUBLIC LIGHTING BRANCH
Summarized results of power quality measurements in public lighting for two cases (HPS and LED
technology) are shown in the table below. Table 5 shows that all power quality parameters are satisfied and
are consistent with standard EN 50160.
Table 5. Table 4. Loads and measurement periods for HPS and LED technology
Power quality parameter HPS technology LED technology
Frequency OK OK
Voltage OK OK
Flicker OK OK
THD OK OK
Unbalance OK OK
Mains signalling OK OK
As is mentioned in the previous chapter, measurements of power quality for both HPS and LED
technology show that all power quality parameters are satisfied and fully compliant with the standard EN
50160. Analysis and comparison of measurement results for each parameter that has changed by changing the
lighting technology is given below. Total harmonic distortion of supply voltage is below the level prescribed
by the standard EN 50160 (8 %), but generally THD in the absolute amount for case of LED is higher by
approximately 0.25 % compared with HPS, as shown in Figure 3 and Figure 4.
Figure 3. Total harmonic distortion of supply voltage – HPS
Figure 4. Total harmonic distortion of supply voltage – LED
 ISSN: 2088-8708
Int J Elec & Comp Eng, Vol. 8, No. 2, April 2018 : 880 – 887
884
Also, in terms of rapid voltage changes, long term flicker severity caused by voltage fluctuations is below the
level prescribed by the Standard. In comparison with LED, HPS technology is more stable due to there are no
so many peaks as in LED technology. Although the mean values of long term flickers are approximately
equal, HPS has no significant deviations from the overall weekly trend (Figure 5 and Figure 6).
Figure 5. Long term flicker – HPS
Figure 6. Long term flicker – LED
Figure 7. Mains signalling voltages – LED
Int J Elec & Comp Eng ISSN: 2088-8708 
Comparative Analysis of Power Quality Indices for Different Lighting Techniogies in …. (Jurica Perko)
885
The presence of mains signalling voltages are also recorded in the power quality measurements.
Recorded values for both cases (HPS and LED) are far below the limits prescribed by the standard EN
50160. In comparison with HPS, mains signalling voltages are slightly higher in the case of LED. Just
because of the presence of such signals, as this is not a common case, an example of an LED case is shown in
this chapter, Figure 7.
Active power and reactive power have also been recorded during the measurements of power
quality. Replacement of old HPS based lamps with LED technology resulted in energy savings. Except the
savings in active power, positive impact on reactive power and power factor is also analysed. Thus, Figure 8
shows 7-day measurements of power and power factor for HPS. It can be noted that the power factor is really
low (0.44 inductive) which results in higher reactive power (3.79 kVAr). In comparison with HPS, LED
technology has an improved power factor (0.95 capacitive) and decreased reactive power (0.06 kVAr),
Figure 9. Figure 9 also shows huge loads in certain moments. It can be assumed that great inrush current has
been recorded because LED lamp contains power electronic device, i.e. LED driver. After stabilization,
active power amounts to 0.17 kW as shown in lamp specification.
Figure 8. Active power, reactive power and power factor – HPS
Figure 9. Active power, reactive power and power factor – LED
5. CONCLUSION
Measurement and analysis of power quality in public lighting for two cases (HPS and LED
technology) show compliance of power quality parameters with the standard EN 50160. Both cases were
compared and the final conclusion based on the results is presented below. All power quality parameters are
within the limitations prescribed by the standard EN 50160. Measurements in accordance with the relating to
voltage dips and swells did not record a single event, meaning there are no unacceptable voltage dips and
swells. The comparison of HPS and LED technologies showed that in the case of LED technology THD is
 ISSN: 2088-8708
Int J Elec & Comp Eng, Vol. 8, No. 2, April 2018 : 880 – 887
886
higher by 0.25 % in absolute value than in the case of HPS. Results of the long term flicker analysis showed
that HPS technology is more stable since there are not so many peaks as in LED technology.
Although the mean values of long term flickers are approximately equal, HPS has no significant
deviations from the overall weekly trend. Also, presence of mains signalling voltages in very low percentage
is recorded (less than 1 %). Namely, the Croatian national energy company manages the public lighting
system through the power line communication method, which uses the technology of coded signal injection
of certain frequency in different voltage level distribution network. Frequency range of injected signals
ranges from 200 Hz to 1,600 Hz. Recorded values in both cases (HPS and LED) are far below the limitations
prescribed in the standard EN 50160. Along with the measurement of power voltage parameters, power
(active and reactive) and power factor measurements were conducted. In the case of HPS, active power of
1.89 kW, reactive power of 3.79 kVAr inductive and power factor of 0.44 are recorded. Low power factor for
HPS is a result of HPS based lamp as inductive load with defective condenser. Such a lamp dampens the grid
with reactive power. Unlike the HPS, active power of 0.17 kW is recorded in LED case what results with
savings of 89 %. Drastic change in reactive power (0.06 kVAr) is noted as well but in capacitive area due to
LED lamp contains power electronic components. By implementing LED lighting, the power factor is
improved (0.95). Generally, LED lighting improves voltage conditions in the distribution network because it
is capacitive load while most of loads in the network are inductive. In this regard, LED lighting behaves as
some type of reactive power compensator.
Analysis of power measurement results of LED lamps showed unusual curve where in 5 of 7 days
power peaks appeared as a result of huge inrush current. It can be assumed that LED driver does not have an
inrush current limiter (e.g. NTC)
ACKNOWLEDGEMENTS
Authors want to thanks to the Municipality of Gola for their permission to perform measurments of
power quality indices on public lighting system.
REFERENCES
[1] J. Perko, Comparison of Grid Rules and Standard HRN EN 50160, Elektrotehničko društvo Zagreb, E-biblioteka,
Zagreb, 2010. (in Croatian).
[2] European Standard, Voltage Characteristics of Electricity Supplied by Public Distribution Networks (EN 50160),
Brussels, Belgium, 2007.
[3] H. Markiewich, A. Klajn, Voltage Disturbances, Standard EN 50160, Guide, European Coper Institute, Wroclaw
University of Technology and Copper Development Association, 2014, Wroclaw, 2014.
[4] F. Outferdine et al., "Feasibility of Substitution of the Conventional Street Lighting Installation by the Photovoltaic
Case Study on a Municipality in Agadir in Morocco," International Journal of Electrical and Computer
Engineering (IJECE), Vol 7, No 5: October 2017
[5] I. Ramljak, J. Perko, M. Žnidarec, “Voltage Flickers as Voltage Quality Problem in Industrial Sector”, The
International Symposium on Power Quality, Teslić, Bosnia and Herzegovina, 2017
[6] M. Wasif Umar et al.,” PWM Dimming for High Brightness LED Based Automotive Lighting Applications”,
International Journal of Electrical and Computer Engineering (IJECE), Vol 7, No 5. October 2017
[7] Ž. Novinc, Power Quality, Graphis, Zagreb, Croatia, 2006. (in Croatian)
[8] Z. Klaić, Mesurement and Analysis of Power Quality in Distribution Network According to European Standard EN
50160, Master work, Osijek, Croatia, 2006. (in Croatian)
BIOGRAPHIES OF AUTHORS
Jurica Perko, MEng (IEEE M91246004;2011) was born in Djakovo on July 13, 1988. He
obtained his BSc degree (2010) and MSc degree (2012) in electrical engineering at the Faculty
of Electrical Engineering, University of Josip Juraj Strossmayer Osijek and currently attending
PhD studies at Faculty of Electrical Engineering, Computer Science and Information Technology
Osijek. Currently he is an Energy Expert at Regional Energy Agency North in Koprivnica,
Croatia. His main interests are renewable energy sources, energy efficiency, public lighting
systems and electro mobility. He has published 10 technical papers in journals and international
conferences. He is a Member of IEEE PES Society, PELS Society and Smart Cities Community.
Int J Elec & Comp Eng ISSN: 2088-8708 
Comparative Analysis of Power Quality Indices for Different Lighting Techniogies in …. (Jurica Perko)
887
Srete Nikolovski, PhD.El.Eng. (IEEE M’1995, SM’2005) was born in Belgrade on October 1,
1954. He obtained his BSc degree (1978) and MSc degree (1989), in electrical engineering at the
Faculty of Electrical Engineering, University of Belgrade and his PhD degree from the Faculty
of Electrical and Computing Engineering, University of Zagreb, Croatia in 1993. Currently he is
a Full Professor at Power Engineering Department at Faculty of Electrical Engineering, J.J.
Strossmayer University in Osijek, Croatia. His main interests are power system protection,
power system modeling, simulation and reliability. He has published 180 technical papers in
journals and international conferences. He is a Senior Member of IEEE Reliability Society, PES
Society and the member of Croatian National Committee of CIGRE
Ljubomir Majdandžić PhD.Mech.Eng, was born on July 4, 1960 in Ivanjska at Banja Luka.
He graduated two post studies: in 1999 at the Faculty of Mechanical Engineering and Naval
Architecture University of Zagreb and in 2001 at the Faculty of Economics in Zagreb. From
2001 to 2003 working on a PhD Thesis at the Fraunhofer Institute for Solar Energy, Department
of electric power systems, in Freiburg, Germany. He obtained his PhD degree at the Faculty of
Electrical Engineering and Computing in Zagreb in 2004. He was associate professor at Faculty
of Electrical Engineering, University of Osijek. Author is of 64 scientific and professional papers
in the field of energy, renewable energy and sustainable development. He is a member of the
International Solar Energy Society (ISES), the German Society for Solar and the Croatian
Energy Association. Now he is senior advisor at Environmental Protection and Energy
Efficiency Fund, Zagreb, Croatia

More Related Content

What's hot

Hysteresis-based Voltage and Current Control Techniques for Grid Connected So...
Hysteresis-based Voltage and Current Control Techniques for Grid Connected So...Hysteresis-based Voltage and Current Control Techniques for Grid Connected So...
Hysteresis-based Voltage and Current Control Techniques for Grid Connected So...IJECEIAES
 
A Study of SEPIC Converter Based Fuzzy Logic Controller For Hybrid System
A Study of SEPIC Converter Based Fuzzy Logic Controller For Hybrid SystemA Study of SEPIC Converter Based Fuzzy Logic Controller For Hybrid System
A Study of SEPIC Converter Based Fuzzy Logic Controller For Hybrid SystemIJRST Journal
 
MPPT oscillations minimization in PV system by controlling non-linear dynamic...
MPPT oscillations minimization in PV system by controlling non-linear dynamic...MPPT oscillations minimization in PV system by controlling non-linear dynamic...
MPPT oscillations minimization in PV system by controlling non-linear dynamic...IJECEIAES
 
Power Quality Enhancement in Grid Connected PV Systemsusing High Step up DC-D...
Power Quality Enhancement in Grid Connected PV Systemsusing High Step up DC-D...Power Quality Enhancement in Grid Connected PV Systemsusing High Step up DC-D...
Power Quality Enhancement in Grid Connected PV Systemsusing High Step up DC-D...IJECEIAES
 
Electronics 09-00331_A Novel General Purpose Combined DFVF/VCII Based Biomedi...
Electronics 09-00331_A Novel General Purpose Combined DFVF/VCII Based Biomedi...Electronics 09-00331_A Novel General Purpose Combined DFVF/VCII Based Biomedi...
Electronics 09-00331_A Novel General Purpose Combined DFVF/VCII Based Biomedi...Hoopeer Hoopeer
 
IRJET - Hybrid Renewable Energy Sources for Power Quality Improvement with In...
IRJET - Hybrid Renewable Energy Sources for Power Quality Improvement with In...IRJET - Hybrid Renewable Energy Sources for Power Quality Improvement with In...
IRJET - Hybrid Renewable Energy Sources for Power Quality Improvement with In...IRJET Journal
 
Application of PI controller based active filter for harmonic mitigation of g...
Application of PI controller based active filter for harmonic mitigation of g...Application of PI controller based active filter for harmonic mitigation of g...
Application of PI controller based active filter for harmonic mitigation of g...journalBEEI
 
seminar report on power quality monitoring
seminar report on power quality monitoring  seminar report on power quality monitoring
seminar report on power quality monitoring khemraj298
 
IRJET- Implementation of 3-Phase Electric Springs in Unbalanced Power Sys...
IRJET-  	  Implementation of 3-Phase Electric Springs in Unbalanced Power Sys...IRJET-  	  Implementation of 3-Phase Electric Springs in Unbalanced Power Sys...
IRJET- Implementation of 3-Phase Electric Springs in Unbalanced Power Sys...IRJET Journal
 
Power Quality & Power Quality Problems
Power Quality & Power Quality ProblemsPower Quality & Power Quality Problems
Power Quality & Power Quality ProblemsPower System Operation
 
Multi Units of Three Phase Photovoltaic using Band Pass Filter to Enhance Pow...
Multi Units of Three Phase Photovoltaic using Band Pass Filter to Enhance Pow...Multi Units of Three Phase Photovoltaic using Band Pass Filter to Enhance Pow...
Multi Units of Three Phase Photovoltaic using Band Pass Filter to Enhance Pow...IJECEIAES
 
International Journal of Engineering Research and Development
International Journal of Engineering Research and DevelopmentInternational Journal of Engineering Research and Development
International Journal of Engineering Research and DevelopmentIJERD Editor
 
Cost effective solar Inverter
Cost effective solar InverterCost effective solar Inverter
Cost effective solar InverterIJERA Editor
 
A 30mV input battery-less power management system
A 30mV input battery-less power management systemA 30mV input battery-less power management system
A 30mV input battery-less power management systemjournalBEEI
 
IRJET- Power Quality Monitoring & Analysis using Smart Multi-Function Meter
IRJET- Power Quality Monitoring & Analysis using Smart Multi-Function MeterIRJET- Power Quality Monitoring & Analysis using Smart Multi-Function Meter
IRJET- Power Quality Monitoring & Analysis using Smart Multi-Function MeterIRJET Journal
 
13 mohamed ezzat final_paper 118-124
13 mohamed ezzat final_paper  118-12413 mohamed ezzat final_paper  118-124
13 mohamed ezzat final_paper 118-124Alexander Decker
 
Model to Evaluate the Performance of Building Integrated Photovoltaic Systems...
Model to Evaluate the Performance of Building Integrated Photovoltaic Systems...Model to Evaluate the Performance of Building Integrated Photovoltaic Systems...
Model to Evaluate the Performance of Building Integrated Photovoltaic Systems...IJECEIAES
 

What's hot (20)

Hysteresis-based Voltage and Current Control Techniques for Grid Connected So...
Hysteresis-based Voltage and Current Control Techniques for Grid Connected So...Hysteresis-based Voltage and Current Control Techniques for Grid Connected So...
Hysteresis-based Voltage and Current Control Techniques for Grid Connected So...
 
A Study of SEPIC Converter Based Fuzzy Logic Controller For Hybrid System
A Study of SEPIC Converter Based Fuzzy Logic Controller For Hybrid SystemA Study of SEPIC Converter Based Fuzzy Logic Controller For Hybrid System
A Study of SEPIC Converter Based Fuzzy Logic Controller For Hybrid System
 
MPPT oscillations minimization in PV system by controlling non-linear dynamic...
MPPT oscillations minimization in PV system by controlling non-linear dynamic...MPPT oscillations minimization in PV system by controlling non-linear dynamic...
MPPT oscillations minimization in PV system by controlling non-linear dynamic...
 
Power Quality Enhancement in Grid Connected PV Systemsusing High Step up DC-D...
Power Quality Enhancement in Grid Connected PV Systemsusing High Step up DC-D...Power Quality Enhancement in Grid Connected PV Systemsusing High Step up DC-D...
Power Quality Enhancement in Grid Connected PV Systemsusing High Step up DC-D...
 
Electronics 09-00331_A Novel General Purpose Combined DFVF/VCII Based Biomedi...
Electronics 09-00331_A Novel General Purpose Combined DFVF/VCII Based Biomedi...Electronics 09-00331_A Novel General Purpose Combined DFVF/VCII Based Biomedi...
Electronics 09-00331_A Novel General Purpose Combined DFVF/VCII Based Biomedi...
 
IRJET - Hybrid Renewable Energy Sources for Power Quality Improvement with In...
IRJET - Hybrid Renewable Energy Sources for Power Quality Improvement with In...IRJET - Hybrid Renewable Energy Sources for Power Quality Improvement with In...
IRJET - Hybrid Renewable Energy Sources for Power Quality Improvement with In...
 
Application of PI controller based active filter for harmonic mitigation of g...
Application of PI controller based active filter for harmonic mitigation of g...Application of PI controller based active filter for harmonic mitigation of g...
Application of PI controller based active filter for harmonic mitigation of g...
 
seminar report on power quality monitoring
seminar report on power quality monitoring  seminar report on power quality monitoring
seminar report on power quality monitoring
 
IRJET- Implementation of 3-Phase Electric Springs in Unbalanced Power Sys...
IRJET-  	  Implementation of 3-Phase Electric Springs in Unbalanced Power Sys...IRJET-  	  Implementation of 3-Phase Electric Springs in Unbalanced Power Sys...
IRJET- Implementation of 3-Phase Electric Springs in Unbalanced Power Sys...
 
Improved Time Responses of PI & FL Controlled SEPIC Converter based Series Re...
Improved Time Responses of PI & FL Controlled SEPIC Converter based Series Re...Improved Time Responses of PI & FL Controlled SEPIC Converter based Series Re...
Improved Time Responses of PI & FL Controlled SEPIC Converter based Series Re...
 
Power Quality & Power Quality Problems
Power Quality & Power Quality ProblemsPower Quality & Power Quality Problems
Power Quality & Power Quality Problems
 
Multi Units of Three Phase Photovoltaic using Band Pass Filter to Enhance Pow...
Multi Units of Three Phase Photovoltaic using Band Pass Filter to Enhance Pow...Multi Units of Three Phase Photovoltaic using Band Pass Filter to Enhance Pow...
Multi Units of Three Phase Photovoltaic using Band Pass Filter to Enhance Pow...
 
Filter Implementation Using Output Transformer of UPS for Power Quality Impro...
Filter Implementation Using Output Transformer of UPS for Power Quality Impro...Filter Implementation Using Output Transformer of UPS for Power Quality Impro...
Filter Implementation Using Output Transformer of UPS for Power Quality Impro...
 
International Journal of Engineering Research and Development
International Journal of Engineering Research and DevelopmentInternational Journal of Engineering Research and Development
International Journal of Engineering Research and Development
 
Investigation of Power Quality Improvement in Super Lift Luo Converter
Investigation of Power Quality Improvement in Super Lift Luo ConverterInvestigation of Power Quality Improvement in Super Lift Luo Converter
Investigation of Power Quality Improvement in Super Lift Luo Converter
 
Cost effective solar Inverter
Cost effective solar InverterCost effective solar Inverter
Cost effective solar Inverter
 
A 30mV input battery-less power management system
A 30mV input battery-less power management systemA 30mV input battery-less power management system
A 30mV input battery-less power management system
 
IRJET- Power Quality Monitoring & Analysis using Smart Multi-Function Meter
IRJET- Power Quality Monitoring & Analysis using Smart Multi-Function MeterIRJET- Power Quality Monitoring & Analysis using Smart Multi-Function Meter
IRJET- Power Quality Monitoring & Analysis using Smart Multi-Function Meter
 
13 mohamed ezzat final_paper 118-124
13 mohamed ezzat final_paper  118-12413 mohamed ezzat final_paper  118-124
13 mohamed ezzat final_paper 118-124
 
Model to Evaluate the Performance of Building Integrated Photovoltaic Systems...
Model to Evaluate the Performance of Building Integrated Photovoltaic Systems...Model to Evaluate the Performance of Building Integrated Photovoltaic Systems...
Model to Evaluate the Performance of Building Integrated Photovoltaic Systems...
 

Similar to Comparative Analysis of Power Quality Indices for Different Lighting Techniogies in Public Lightning

Power Quality & Benefits of Power Quality
Power Quality & Benefits of Power Quality Power Quality & Benefits of Power Quality
Power Quality & Benefits of Power Quality Power System Operation
 
IRJET- Optimal Control of Multilevel Inverter to Minimize Harmonic Distortion...
IRJET- Optimal Control of Multilevel Inverter to Minimize Harmonic Distortion...IRJET- Optimal Control of Multilevel Inverter to Minimize Harmonic Distortion...
IRJET- Optimal Control of Multilevel Inverter to Minimize Harmonic Distortion...IRJET Journal
 
Harmonic enhancement in microgrid with applications on sensitive loads
Harmonic enhancement in microgrid with applications on sensitive loadsHarmonic enhancement in microgrid with applications on sensitive loads
Harmonic enhancement in microgrid with applications on sensitive loadsIJECEIAES
 
A Review On Power Quality Issues and Standards
A Review On Power Quality Issues and StandardsA Review On Power Quality Issues and Standards
A Review On Power Quality Issues and StandardsIRJET Journal
 
Harmonic assessment on two photovoltaic inverter modes and mathematical model...
Harmonic assessment on two photovoltaic inverter modes and mathematical model...Harmonic assessment on two photovoltaic inverter modes and mathematical model...
Harmonic assessment on two photovoltaic inverter modes and mathematical model...IJECEIAES
 
Save energy and protect your facility with voltage optimisation
Save energy and protect your facility with voltage optimisationSave energy and protect your facility with voltage optimisation
Save energy and protect your facility with voltage optimisationNick Lee
 
presentation of Conference On Electrical And Electronic Engineering 2015
presentation of Conference On Electrical And Electronic Engineering 2015presentation of Conference On Electrical And Electronic Engineering 2015
presentation of Conference On Electrical And Electronic Engineering 2015sager alswed
 
ANALYSIS AND SIMULATION OF HARMONICS FOR VARIOUS RESIDENTIAL LOADS USING SIMU...
ANALYSIS AND SIMULATION OF HARMONICS FOR VARIOUS RESIDENTIAL LOADS USING SIMU...ANALYSIS AND SIMULATION OF HARMONICS FOR VARIOUS RESIDENTIAL LOADS USING SIMU...
ANALYSIS AND SIMULATION OF HARMONICS FOR VARIOUS RESIDENTIAL LOADS USING SIMU...ijiert bestjournal
 
A New Power Factor Correction Technique using PFC Boost Converter
A New Power Factor Correction Technique using PFC Boost ConverterA New Power Factor Correction Technique using PFC Boost Converter
A New Power Factor Correction Technique using PFC Boost ConverterYogeshIJTSRD
 
Voltage characteristics an overlooked contributor to power quality assessment
Voltage characteristics an overlooked contributor to power quality assessmentVoltage characteristics an overlooked contributor to power quality assessment
Voltage characteristics an overlooked contributor to power quality assessmentsunny katyara
 
SIMULATION OF REDUCED SWITCH INVERTER BASED UPQC WITH FUZZY LOGIC AND ANN CON...
SIMULATION OF REDUCED SWITCH INVERTER BASED UPQC WITH FUZZY LOGIC AND ANN CON...SIMULATION OF REDUCED SWITCH INVERTER BASED UPQC WITH FUZZY LOGIC AND ANN CON...
SIMULATION OF REDUCED SWITCH INVERTER BASED UPQC WITH FUZZY LOGIC AND ANN CON...MABUSUBANI SHAIK
 
MODELING AND SIMULATION OF SOLAR PHOTOVOLTAIC APPLICATION BASED MULTILEVEL IN...
MODELING AND SIMULATION OF SOLAR PHOTOVOLTAIC APPLICATION BASED MULTILEVEL IN...MODELING AND SIMULATION OF SOLAR PHOTOVOLTAIC APPLICATION BASED MULTILEVEL IN...
MODELING AND SIMULATION OF SOLAR PHOTOVOLTAIC APPLICATION BASED MULTILEVEL IN...ecij
 
Grid Connected PV System with Power Quality Improvement Using Intelligent Con...
Grid Connected PV System with Power Quality Improvement Using Intelligent Con...Grid Connected PV System with Power Quality Improvement Using Intelligent Con...
Grid Connected PV System with Power Quality Improvement Using Intelligent Con...IJMTST Journal
 
Unified power quality conditioner for compensating power quality problem ad
Unified power quality conditioner for compensating power quality problem adUnified power quality conditioner for compensating power quality problem ad
Unified power quality conditioner for compensating power quality problem adIAEME Publication
 
Power quality improvement by series active power filter- a review
Power quality improvement by series active power filter- a reviewPower quality improvement by series active power filter- a review
Power quality improvement by series active power filter- a reviewIRJET Journal
 
Parasitic Boost Circuit for Transform Less Active Voltage Quality Regulator
Parasitic Boost Circuit for Transform Less Active Voltage Quality RegulatorParasitic Boost Circuit for Transform Less Active Voltage Quality Regulator
Parasitic Boost Circuit for Transform Less Active Voltage Quality RegulatorIJMTST Journal
 

Similar to Comparative Analysis of Power Quality Indices for Different Lighting Techniogies in Public Lightning (20)

Power Quality & Benefits of Power Quality
Power Quality & Benefits of Power Quality Power Quality & Benefits of Power Quality
Power Quality & Benefits of Power Quality
 
IRJET- Optimal Control of Multilevel Inverter to Minimize Harmonic Distortion...
IRJET- Optimal Control of Multilevel Inverter to Minimize Harmonic Distortion...IRJET- Optimal Control of Multilevel Inverter to Minimize Harmonic Distortion...
IRJET- Optimal Control of Multilevel Inverter to Minimize Harmonic Distortion...
 
Harmonic enhancement in microgrid with applications on sensitive loads
Harmonic enhancement in microgrid with applications on sensitive loadsHarmonic enhancement in microgrid with applications on sensitive loads
Harmonic enhancement in microgrid with applications on sensitive loads
 
A Review On Power Quality Issues and Standards
A Review On Power Quality Issues and StandardsA Review On Power Quality Issues and Standards
A Review On Power Quality Issues and Standards
 
Harmonic assessment on two photovoltaic inverter modes and mathematical model...
Harmonic assessment on two photovoltaic inverter modes and mathematical model...Harmonic assessment on two photovoltaic inverter modes and mathematical model...
Harmonic assessment on two photovoltaic inverter modes and mathematical model...
 
Save energy and protect your facility with voltage optimisation
Save energy and protect your facility with voltage optimisationSave energy and protect your facility with voltage optimisation
Save energy and protect your facility with voltage optimisation
 
Power Quality Standards
Power Quality StandardsPower Quality Standards
Power Quality Standards
 
presentation of Conference On Electrical And Electronic Engineering 2015
presentation of Conference On Electrical And Electronic Engineering 2015presentation of Conference On Electrical And Electronic Engineering 2015
presentation of Conference On Electrical And Electronic Engineering 2015
 
ANALYSIS AND SIMULATION OF HARMONICS FOR VARIOUS RESIDENTIAL LOADS USING SIMU...
ANALYSIS AND SIMULATION OF HARMONICS FOR VARIOUS RESIDENTIAL LOADS USING SIMU...ANALYSIS AND SIMULATION OF HARMONICS FOR VARIOUS RESIDENTIAL LOADS USING SIMU...
ANALYSIS AND SIMULATION OF HARMONICS FOR VARIOUS RESIDENTIAL LOADS USING SIMU...
 
Application of a Hadoop-based Distributed System for Offline Processing of Po...
Application of a Hadoop-based Distributed System for Offline Processing of Po...Application of a Hadoop-based Distributed System for Offline Processing of Po...
Application of a Hadoop-based Distributed System for Offline Processing of Po...
 
A New Power Factor Correction Technique using PFC Boost Converter
A New Power Factor Correction Technique using PFC Boost ConverterA New Power Factor Correction Technique using PFC Boost Converter
A New Power Factor Correction Technique using PFC Boost Converter
 
Voltage characteristics an overlooked contributor to power quality assessment
Voltage characteristics an overlooked contributor to power quality assessmentVoltage characteristics an overlooked contributor to power quality assessment
Voltage characteristics an overlooked contributor to power quality assessment
 
SIMULATION OF REDUCED SWITCH INVERTER BASED UPQC WITH FUZZY LOGIC AND ANN CON...
SIMULATION OF REDUCED SWITCH INVERTER BASED UPQC WITH FUZZY LOGIC AND ANN CON...SIMULATION OF REDUCED SWITCH INVERTER BASED UPQC WITH FUZZY LOGIC AND ANN CON...
SIMULATION OF REDUCED SWITCH INVERTER BASED UPQC WITH FUZZY LOGIC AND ANN CON...
 
MODELING AND SIMULATION OF SOLAR PHOTOVOLTAIC APPLICATION BASED MULTILEVEL IN...
MODELING AND SIMULATION OF SOLAR PHOTOVOLTAIC APPLICATION BASED MULTILEVEL IN...MODELING AND SIMULATION OF SOLAR PHOTOVOLTAIC APPLICATION BASED MULTILEVEL IN...
MODELING AND SIMULATION OF SOLAR PHOTOVOLTAIC APPLICATION BASED MULTILEVEL IN...
 
Reactive energy metering
Reactive energy meteringReactive energy metering
Reactive energy metering
 
Grid Connected PV System with Power Quality Improvement Using Intelligent Con...
Grid Connected PV System with Power Quality Improvement Using Intelligent Con...Grid Connected PV System with Power Quality Improvement Using Intelligent Con...
Grid Connected PV System with Power Quality Improvement Using Intelligent Con...
 
Ab04404170177
Ab04404170177Ab04404170177
Ab04404170177
 
Unified power quality conditioner for compensating power quality problem ad
Unified power quality conditioner for compensating power quality problem adUnified power quality conditioner for compensating power quality problem ad
Unified power quality conditioner for compensating power quality problem ad
 
Power quality improvement by series active power filter- a review
Power quality improvement by series active power filter- a reviewPower quality improvement by series active power filter- a review
Power quality improvement by series active power filter- a review
 
Parasitic Boost Circuit for Transform Less Active Voltage Quality Regulator
Parasitic Boost Circuit for Transform Less Active Voltage Quality RegulatorParasitic Boost Circuit for Transform Less Active Voltage Quality Regulator
Parasitic Boost Circuit for Transform Less Active Voltage Quality Regulator
 

More from IJECEIAES

Cloud service ranking with an integration of k-means algorithm and decision-m...
Cloud service ranking with an integration of k-means algorithm and decision-m...Cloud service ranking with an integration of k-means algorithm and decision-m...
Cloud service ranking with an integration of k-means algorithm and decision-m...IJECEIAES
 
Prediction of the risk of developing heart disease using logistic regression
Prediction of the risk of developing heart disease using logistic regressionPrediction of the risk of developing heart disease using logistic regression
Prediction of the risk of developing heart disease using logistic regressionIJECEIAES
 
Predictive analysis of terrorist activities in Thailand's Southern provinces:...
Predictive analysis of terrorist activities in Thailand's Southern provinces:...Predictive analysis of terrorist activities in Thailand's Southern provinces:...
Predictive analysis of terrorist activities in Thailand's Southern provinces:...IJECEIAES
 
Optimal model of vehicular ad-hoc network assisted by unmanned aerial vehicl...
Optimal model of vehicular ad-hoc network assisted by  unmanned aerial vehicl...Optimal model of vehicular ad-hoc network assisted by  unmanned aerial vehicl...
Optimal model of vehicular ad-hoc network assisted by unmanned aerial vehicl...IJECEIAES
 
Improving cyberbullying detection through multi-level machine learning
Improving cyberbullying detection through multi-level machine learningImproving cyberbullying detection through multi-level machine learning
Improving cyberbullying detection through multi-level machine learningIJECEIAES
 
Comparison of time series temperature prediction with autoregressive integrat...
Comparison of time series temperature prediction with autoregressive integrat...Comparison of time series temperature prediction with autoregressive integrat...
Comparison of time series temperature prediction with autoregressive integrat...IJECEIAES
 
Strengthening data integrity in academic document recording with blockchain a...
Strengthening data integrity in academic document recording with blockchain a...Strengthening data integrity in academic document recording with blockchain a...
Strengthening data integrity in academic document recording with blockchain a...IJECEIAES
 
Design of storage benchmark kit framework for supporting the file storage ret...
Design of storage benchmark kit framework for supporting the file storage ret...Design of storage benchmark kit framework for supporting the file storage ret...
Design of storage benchmark kit framework for supporting the file storage ret...IJECEIAES
 
Detection of diseases in rice leaf using convolutional neural network with tr...
Detection of diseases in rice leaf using convolutional neural network with tr...Detection of diseases in rice leaf using convolutional neural network with tr...
Detection of diseases in rice leaf using convolutional neural network with tr...IJECEIAES
 
A systematic review of in-memory database over multi-tenancy
A systematic review of in-memory database over multi-tenancyA systematic review of in-memory database over multi-tenancy
A systematic review of in-memory database over multi-tenancyIJECEIAES
 
Agriculture crop yield prediction using inertia based cat swarm optimization
Agriculture crop yield prediction using inertia based cat swarm optimizationAgriculture crop yield prediction using inertia based cat swarm optimization
Agriculture crop yield prediction using inertia based cat swarm optimizationIJECEIAES
 
Three layer hybrid learning to improve intrusion detection system performance
Three layer hybrid learning to improve intrusion detection system performanceThree layer hybrid learning to improve intrusion detection system performance
Three layer hybrid learning to improve intrusion detection system performanceIJECEIAES
 
Non-binary codes approach on the performance of short-packet full-duplex tran...
Non-binary codes approach on the performance of short-packet full-duplex tran...Non-binary codes approach on the performance of short-packet full-duplex tran...
Non-binary codes approach on the performance of short-packet full-duplex tran...IJECEIAES
 
Improved design and performance of the global rectenna system for wireless po...
Improved design and performance of the global rectenna system for wireless po...Improved design and performance of the global rectenna system for wireless po...
Improved design and performance of the global rectenna system for wireless po...IJECEIAES
 
Advanced hybrid algorithms for precise multipath channel estimation in next-g...
Advanced hybrid algorithms for precise multipath channel estimation in next-g...Advanced hybrid algorithms for precise multipath channel estimation in next-g...
Advanced hybrid algorithms for precise multipath channel estimation in next-g...IJECEIAES
 
Performance analysis of 2D optical code division multiple access through unde...
Performance analysis of 2D optical code division multiple access through unde...Performance analysis of 2D optical code division multiple access through unde...
Performance analysis of 2D optical code division multiple access through unde...IJECEIAES
 
On performance analysis of non-orthogonal multiple access downlink for cellul...
On performance analysis of non-orthogonal multiple access downlink for cellul...On performance analysis of non-orthogonal multiple access downlink for cellul...
On performance analysis of non-orthogonal multiple access downlink for cellul...IJECEIAES
 
Phase delay through slot-line beam switching microstrip patch array antenna d...
Phase delay through slot-line beam switching microstrip patch array antenna d...Phase delay through slot-line beam switching microstrip patch array antenna d...
Phase delay through slot-line beam switching microstrip patch array antenna d...IJECEIAES
 
A simple feed orthogonal excitation X-band dual circular polarized microstrip...
A simple feed orthogonal excitation X-band dual circular polarized microstrip...A simple feed orthogonal excitation X-band dual circular polarized microstrip...
A simple feed orthogonal excitation X-band dual circular polarized microstrip...IJECEIAES
 
A taxonomy on power optimization techniques for fifthgeneration heterogenous ...
A taxonomy on power optimization techniques for fifthgeneration heterogenous ...A taxonomy on power optimization techniques for fifthgeneration heterogenous ...
A taxonomy on power optimization techniques for fifthgeneration heterogenous ...IJECEIAES
 

More from IJECEIAES (20)

Cloud service ranking with an integration of k-means algorithm and decision-m...
Cloud service ranking with an integration of k-means algorithm and decision-m...Cloud service ranking with an integration of k-means algorithm and decision-m...
Cloud service ranking with an integration of k-means algorithm and decision-m...
 
Prediction of the risk of developing heart disease using logistic regression
Prediction of the risk of developing heart disease using logistic regressionPrediction of the risk of developing heart disease using logistic regression
Prediction of the risk of developing heart disease using logistic regression
 
Predictive analysis of terrorist activities in Thailand's Southern provinces:...
Predictive analysis of terrorist activities in Thailand's Southern provinces:...Predictive analysis of terrorist activities in Thailand's Southern provinces:...
Predictive analysis of terrorist activities in Thailand's Southern provinces:...
 
Optimal model of vehicular ad-hoc network assisted by unmanned aerial vehicl...
Optimal model of vehicular ad-hoc network assisted by  unmanned aerial vehicl...Optimal model of vehicular ad-hoc network assisted by  unmanned aerial vehicl...
Optimal model of vehicular ad-hoc network assisted by unmanned aerial vehicl...
 
Improving cyberbullying detection through multi-level machine learning
Improving cyberbullying detection through multi-level machine learningImproving cyberbullying detection through multi-level machine learning
Improving cyberbullying detection through multi-level machine learning
 
Comparison of time series temperature prediction with autoregressive integrat...
Comparison of time series temperature prediction with autoregressive integrat...Comparison of time series temperature prediction with autoregressive integrat...
Comparison of time series temperature prediction with autoregressive integrat...
 
Strengthening data integrity in academic document recording with blockchain a...
Strengthening data integrity in academic document recording with blockchain a...Strengthening data integrity in academic document recording with blockchain a...
Strengthening data integrity in academic document recording with blockchain a...
 
Design of storage benchmark kit framework for supporting the file storage ret...
Design of storage benchmark kit framework for supporting the file storage ret...Design of storage benchmark kit framework for supporting the file storage ret...
Design of storage benchmark kit framework for supporting the file storage ret...
 
Detection of diseases in rice leaf using convolutional neural network with tr...
Detection of diseases in rice leaf using convolutional neural network with tr...Detection of diseases in rice leaf using convolutional neural network with tr...
Detection of diseases in rice leaf using convolutional neural network with tr...
 
A systematic review of in-memory database over multi-tenancy
A systematic review of in-memory database over multi-tenancyA systematic review of in-memory database over multi-tenancy
A systematic review of in-memory database over multi-tenancy
 
Agriculture crop yield prediction using inertia based cat swarm optimization
Agriculture crop yield prediction using inertia based cat swarm optimizationAgriculture crop yield prediction using inertia based cat swarm optimization
Agriculture crop yield prediction using inertia based cat swarm optimization
 
Three layer hybrid learning to improve intrusion detection system performance
Three layer hybrid learning to improve intrusion detection system performanceThree layer hybrid learning to improve intrusion detection system performance
Three layer hybrid learning to improve intrusion detection system performance
 
Non-binary codes approach on the performance of short-packet full-duplex tran...
Non-binary codes approach on the performance of short-packet full-duplex tran...Non-binary codes approach on the performance of short-packet full-duplex tran...
Non-binary codes approach on the performance of short-packet full-duplex tran...
 
Improved design and performance of the global rectenna system for wireless po...
Improved design and performance of the global rectenna system for wireless po...Improved design and performance of the global rectenna system for wireless po...
Improved design and performance of the global rectenna system for wireless po...
 
Advanced hybrid algorithms for precise multipath channel estimation in next-g...
Advanced hybrid algorithms for precise multipath channel estimation in next-g...Advanced hybrid algorithms for precise multipath channel estimation in next-g...
Advanced hybrid algorithms for precise multipath channel estimation in next-g...
 
Performance analysis of 2D optical code division multiple access through unde...
Performance analysis of 2D optical code division multiple access through unde...Performance analysis of 2D optical code division multiple access through unde...
Performance analysis of 2D optical code division multiple access through unde...
 
On performance analysis of non-orthogonal multiple access downlink for cellul...
On performance analysis of non-orthogonal multiple access downlink for cellul...On performance analysis of non-orthogonal multiple access downlink for cellul...
On performance analysis of non-orthogonal multiple access downlink for cellul...
 
Phase delay through slot-line beam switching microstrip patch array antenna d...
Phase delay through slot-line beam switching microstrip patch array antenna d...Phase delay through slot-line beam switching microstrip patch array antenna d...
Phase delay through slot-line beam switching microstrip patch array antenna d...
 
A simple feed orthogonal excitation X-band dual circular polarized microstrip...
A simple feed orthogonal excitation X-band dual circular polarized microstrip...A simple feed orthogonal excitation X-band dual circular polarized microstrip...
A simple feed orthogonal excitation X-band dual circular polarized microstrip...
 
A taxonomy on power optimization techniques for fifthgeneration heterogenous ...
A taxonomy on power optimization techniques for fifthgeneration heterogenous ...A taxonomy on power optimization techniques for fifthgeneration heterogenous ...
A taxonomy on power optimization techniques for fifthgeneration heterogenous ...
 

Recently uploaded

High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
 
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLSMANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLSSIVASHANKAR N
 
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝soniya singh
 
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...ranjana rawat
 
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...Dr.Costas Sachpazis
 
the ladakh protest in leh ladakh 2024 sonam wangchuk.pptx
the ladakh protest in leh ladakh 2024 sonam wangchuk.pptxthe ladakh protest in leh ladakh 2024 sonam wangchuk.pptx
the ladakh protest in leh ladakh 2024 sonam wangchuk.pptxhumanexperienceaaa
 
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Call Girls in Nagpur High Profile
 
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur EscortsCall Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
 
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...ranjana rawat
 
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...Call Girls in Nagpur High Profile
 
(TARA) Talegaon Dabhade Call Girls Just Call 7001035870 [ Cash on Delivery ] ...
(TARA) Talegaon Dabhade Call Girls Just Call 7001035870 [ Cash on Delivery ] ...(TARA) Talegaon Dabhade Call Girls Just Call 7001035870 [ Cash on Delivery ] ...
(TARA) Talegaon Dabhade Call Girls Just Call 7001035870 [ Cash on Delivery ] ...ranjana rawat
 
Software Development Life Cycle By Team Orange (Dept. of Pharmacy)
Software Development Life Cycle By  Team Orange (Dept. of Pharmacy)Software Development Life Cycle By  Team Orange (Dept. of Pharmacy)
Software Development Life Cycle By Team Orange (Dept. of Pharmacy)Suman Mia
 
Extrusion Processes and Their Limitations
Extrusion Processes and Their LimitationsExtrusion Processes and Their Limitations
Extrusion Processes and Their Limitations120cr0395
 
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Serviceranjana rawat
 
Coefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxCoefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxAsutosh Ranjan
 
Porous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingPorous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingrakeshbaidya232001
 
IMPLICATIONS OF THE ABOVE HOLISTIC UNDERSTANDING OF HARMONY ON PROFESSIONAL E...
IMPLICATIONS OF THE ABOVE HOLISTIC UNDERSTANDING OF HARMONY ON PROFESSIONAL E...IMPLICATIONS OF THE ABOVE HOLISTIC UNDERSTANDING OF HARMONY ON PROFESSIONAL E...
IMPLICATIONS OF THE ABOVE HOLISTIC UNDERSTANDING OF HARMONY ON PROFESSIONAL E...RajaP95
 
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptxDecoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptxJoão Esperancinha
 
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSAPPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSKurinjimalarL3
 
Processing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptxProcessing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptxpranjaldaimarysona
 

Recently uploaded (20)

High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
 
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLSMANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
 
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝
 
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
 
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
 
the ladakh protest in leh ladakh 2024 sonam wangchuk.pptx
the ladakh protest in leh ladakh 2024 sonam wangchuk.pptxthe ladakh protest in leh ladakh 2024 sonam wangchuk.pptx
the ladakh protest in leh ladakh 2024 sonam wangchuk.pptx
 
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
 
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur EscortsCall Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
 
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
 
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...
 
(TARA) Talegaon Dabhade Call Girls Just Call 7001035870 [ Cash on Delivery ] ...
(TARA) Talegaon Dabhade Call Girls Just Call 7001035870 [ Cash on Delivery ] ...(TARA) Talegaon Dabhade Call Girls Just Call 7001035870 [ Cash on Delivery ] ...
(TARA) Talegaon Dabhade Call Girls Just Call 7001035870 [ Cash on Delivery ] ...
 
Software Development Life Cycle By Team Orange (Dept. of Pharmacy)
Software Development Life Cycle By  Team Orange (Dept. of Pharmacy)Software Development Life Cycle By  Team Orange (Dept. of Pharmacy)
Software Development Life Cycle By Team Orange (Dept. of Pharmacy)
 
Extrusion Processes and Their Limitations
Extrusion Processes and Their LimitationsExtrusion Processes and Their Limitations
Extrusion Processes and Their Limitations
 
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
 
Coefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxCoefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptx
 
Porous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingPorous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writing
 
IMPLICATIONS OF THE ABOVE HOLISTIC UNDERSTANDING OF HARMONY ON PROFESSIONAL E...
IMPLICATIONS OF THE ABOVE HOLISTIC UNDERSTANDING OF HARMONY ON PROFESSIONAL E...IMPLICATIONS OF THE ABOVE HOLISTIC UNDERSTANDING OF HARMONY ON PROFESSIONAL E...
IMPLICATIONS OF THE ABOVE HOLISTIC UNDERSTANDING OF HARMONY ON PROFESSIONAL E...
 
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptxDecoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
 
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSAPPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
 
Processing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptxProcessing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptx
 

Comparative Analysis of Power Quality Indices for Different Lighting Techniogies in Public Lightning

  • 1. International Journal of Electrical and Computer Engineering (IJECE) Vol. 8, No. 2, April 2018, pp. 880~887 ISSN: 2088-8708, DOI: 10.11591/ijece.v8i2.pp880-887  880 Journal homepage: http://iaescore.com/journals/index.php/IJECE Comparative Analysis of Power Quality Indices for Different Lighting Techniogies in Public Lightning Jurica Perko1 , Srete Nikolovski2 , Ljubomir Majdandžić3 1 Regional Energy Agency North, Koprivnica, Croatia 2 Faculty of Electrical Engineering, Computer Science and Information Technology, University of Osijek, Croatia 3 Environmental Protections and Energy Efficiency Fund, Zagreb, Croati Article Info ABSTRACT Article history: Received Oct 25, 2017 Revised Jan 4, 2018 Accepted Jan 18, 2018 As with any other product, having electricity of a certain quality is very important for consumers. Its quality has become the key feature that can be disturbed by loads based on power electronic devices. Electricity producers are striving to provide reliable and quality electricity supply to consumers. Public lighting systems that are based on LED lighting technology can potentially positively or negatively affect the power quality because they contain power electronics components in LED drivers. Because of that, two 7-day measurements were conducted on the same public lighting branch but with different lighting technologies (high pressure sodium, known as HPS and LED technology). Results of the measurements were analysed and compared. By analysing the results, other problems were also identified by using LED lighting technology. These problems are addressed in the conclusion of the paper. Keyword: EN 50160 norm High pressure sodium Inrush current LED lighting Power quality Public lighting system Copyright © 2018 Institute of Advanced Engineering and Science. All rights reserved. Corresponding Author: Srete Nikolovski, Departement of Power Engineering, Faculty of Electrical Engineering Computing and Information Technology, University of Osijek, K. Trpimira 2B, 31000 Osijek, Croatia. Email: srete.nikolovski@etfos.hr 1. INTRODUCTION In the recent period, electricity has started to be considered a product as any other, and its quality has become a very important feature for its consumers. A major problem in power quality is created by consumers based on power electronic devices because they draw non-linear current, which results in voltage distortion generation. The first step in solving this problem is measuring and analysing power quality. Power quality standard EN 50160 gives quantitative requirements for voltage in normal conditions. Its purpose is to describe voltage characteristics in terms of [1]: frequency, waveform, symmetry, magnitude. Measurement of power quality according to the standard EN 50160 requires specialized instruments and measuring methods which enables continuous monitoring of the following parameters [2], [3], frequency, supply voltage. total harmonic distortion. supply voltage unbalance, flickers, mains signalling voltage. In [3] is presented a technical and economic study of the solar powered street lighting system of a municipality in the south of Morocco. The state of the conventional street lighting system is compared with PV-based lighting. Power quality parameters, statistical evaluation and compliance limits are given in some papers such as [4]. The voltage flickers as voltage quality problem in industrial sector are presented in [5]. The use of high brightness LEDs has become increasingly accepted as light sources in mainstream vehicles and is presented in [6].
  • 2. Int J Elec & Comp Eng ISSN: 2088-8708  Comparative Analysis of Power Quality Indices for Different Lighting Techniogies in …. (Jurica Perko) 881 2. POWER QUALITY INDICES Power quality parameters, statistical evaluation and compliance limits are given in below in Table 1 Table 1. Supply voltage parameters according to EN 50160 Supply voltage parameter Statistical levels Compliance limit Power frequency 95 % of the time in 1 week 50 Hz ± 1 % 100 % of the time in 1 week 50 Hz + 4 % to - 6 % Supply voltage variations Supply voltage variations 95 % of the time in 1 week Flickers 95 % of the time in 1 week ≤ 1 Supply voltage unbalance 95 % of the time in 1 week < 2 % Individual harmonic voltages 95 % of the time in 1 week See Table 2 Total harmonic distortion 95 % of the time in 1 week < 8 % Mains signalling voltage 95 % of the time in 1 week See Figure 1 Maximal values of odd individual harmonics in percent of nominal voltage are shown in Table 2. Table 2. Values of individual harmonic voltages according to EN 50160 Odd harmonics not multiples of 3 Odd harmonics multiples of 3 Order Uh in % of Un Order Uh in % of Un 5 6.0 3 5.0 7 5.0 9 1.5 11 3.5 15 0.5 13 3.0 21 0.5 17 2.0 19 1.5 23 1.5 25 1.5 Also, the presence of mains signalling voltages was recorded in power quality measurements because the Croatian national energy company manages the public lighting system through the power line communication method. Due to this, there are limitations on voltage levels of signal frequencies in percent of Uc used in public low voltage distribution networks. Figure 1. Voltage levels of signal frequencies in low voltage networks
  • 3.  ISSN: 2088-8708 Int J Elec & Comp Eng, Vol. 8, No. 2, April 2018 : 880 – 887 882 3. MEASUREMENT OF POWER QUALITY ON PUBLIC LIGHTING BRANCH Measurements are conducted according to the standard EN 50160 with class A measuring device in 7 days’ period. The measuring device is a universal tool for power quality analysis and detection of disorder in low and medium voltage distribution network. Specifications of class A three phase power quality measuring device are shown in Table 3 below. Table 3. Specification of measuring device IEC 61000-4-30 compliance Class A Voltage  Current  Frequency  Dips and swells  Harmonics  Power and energy  Energy loss calculator  Unbalance  Inrush  Power wave  Flicker  Transients  Mains signalling  Power inverter efficiency  Measurement of power quality is conducted in the same public lighting cabinet on the same branch for both technologies; LED and HPS. Measurements were conducted over a 7-day period, and the figure below shows the point of measurement in relation to the transformer station as shown in Figure 2. Figure 2. Measurement point in relation with transformer station Loads and measurement periods for both cases High Pressure Sodium (HPS) and Ligh-Emitting Diode (LED) technology are shown in Table 4. Table 4. Loads and measurement periods for HPS and LED technology Lighting technology Number of lamps Lamp power [W] Total lamp power [W] Measurement period HPS 10 189 1,890 7 February 2017 – 14 February 2017 LED 10 17 170 10 March 2017 – 17 March 2017
  • 4. Int J Elec & Comp Eng ISSN: 2088-8708  Comparative Analysis of Power Quality Indices for Different Lighting Techniogies in …. (Jurica Perko) 883 4. RESULTS OF POWER QUALITY MEASUREMENTS ON PUBLIC LIGHTING BRANCH Summarized results of power quality measurements in public lighting for two cases (HPS and LED technology) are shown in the table below. Table 5 shows that all power quality parameters are satisfied and are consistent with standard EN 50160. Table 5. Table 4. Loads and measurement periods for HPS and LED technology Power quality parameter HPS technology LED technology Frequency OK OK Voltage OK OK Flicker OK OK THD OK OK Unbalance OK OK Mains signalling OK OK As is mentioned in the previous chapter, measurements of power quality for both HPS and LED technology show that all power quality parameters are satisfied and fully compliant with the standard EN 50160. Analysis and comparison of measurement results for each parameter that has changed by changing the lighting technology is given below. Total harmonic distortion of supply voltage is below the level prescribed by the standard EN 50160 (8 %), but generally THD in the absolute amount for case of LED is higher by approximately 0.25 % compared with HPS, as shown in Figure 3 and Figure 4. Figure 3. Total harmonic distortion of supply voltage – HPS Figure 4. Total harmonic distortion of supply voltage – LED
  • 5.  ISSN: 2088-8708 Int J Elec & Comp Eng, Vol. 8, No. 2, April 2018 : 880 – 887 884 Also, in terms of rapid voltage changes, long term flicker severity caused by voltage fluctuations is below the level prescribed by the Standard. In comparison with LED, HPS technology is more stable due to there are no so many peaks as in LED technology. Although the mean values of long term flickers are approximately equal, HPS has no significant deviations from the overall weekly trend (Figure 5 and Figure 6). Figure 5. Long term flicker – HPS Figure 6. Long term flicker – LED Figure 7. Mains signalling voltages – LED
  • 6. Int J Elec & Comp Eng ISSN: 2088-8708  Comparative Analysis of Power Quality Indices for Different Lighting Techniogies in …. (Jurica Perko) 885 The presence of mains signalling voltages are also recorded in the power quality measurements. Recorded values for both cases (HPS and LED) are far below the limits prescribed by the standard EN 50160. In comparison with HPS, mains signalling voltages are slightly higher in the case of LED. Just because of the presence of such signals, as this is not a common case, an example of an LED case is shown in this chapter, Figure 7. Active power and reactive power have also been recorded during the measurements of power quality. Replacement of old HPS based lamps with LED technology resulted in energy savings. Except the savings in active power, positive impact on reactive power and power factor is also analysed. Thus, Figure 8 shows 7-day measurements of power and power factor for HPS. It can be noted that the power factor is really low (0.44 inductive) which results in higher reactive power (3.79 kVAr). In comparison with HPS, LED technology has an improved power factor (0.95 capacitive) and decreased reactive power (0.06 kVAr), Figure 9. Figure 9 also shows huge loads in certain moments. It can be assumed that great inrush current has been recorded because LED lamp contains power electronic device, i.e. LED driver. After stabilization, active power amounts to 0.17 kW as shown in lamp specification. Figure 8. Active power, reactive power and power factor – HPS Figure 9. Active power, reactive power and power factor – LED 5. CONCLUSION Measurement and analysis of power quality in public lighting for two cases (HPS and LED technology) show compliance of power quality parameters with the standard EN 50160. Both cases were compared and the final conclusion based on the results is presented below. All power quality parameters are within the limitations prescribed by the standard EN 50160. Measurements in accordance with the relating to voltage dips and swells did not record a single event, meaning there are no unacceptable voltage dips and swells. The comparison of HPS and LED technologies showed that in the case of LED technology THD is
  • 7.  ISSN: 2088-8708 Int J Elec & Comp Eng, Vol. 8, No. 2, April 2018 : 880 – 887 886 higher by 0.25 % in absolute value than in the case of HPS. Results of the long term flicker analysis showed that HPS technology is more stable since there are not so many peaks as in LED technology. Although the mean values of long term flickers are approximately equal, HPS has no significant deviations from the overall weekly trend. Also, presence of mains signalling voltages in very low percentage is recorded (less than 1 %). Namely, the Croatian national energy company manages the public lighting system through the power line communication method, which uses the technology of coded signal injection of certain frequency in different voltage level distribution network. Frequency range of injected signals ranges from 200 Hz to 1,600 Hz. Recorded values in both cases (HPS and LED) are far below the limitations prescribed in the standard EN 50160. Along with the measurement of power voltage parameters, power (active and reactive) and power factor measurements were conducted. In the case of HPS, active power of 1.89 kW, reactive power of 3.79 kVAr inductive and power factor of 0.44 are recorded. Low power factor for HPS is a result of HPS based lamp as inductive load with defective condenser. Such a lamp dampens the grid with reactive power. Unlike the HPS, active power of 0.17 kW is recorded in LED case what results with savings of 89 %. Drastic change in reactive power (0.06 kVAr) is noted as well but in capacitive area due to LED lamp contains power electronic components. By implementing LED lighting, the power factor is improved (0.95). Generally, LED lighting improves voltage conditions in the distribution network because it is capacitive load while most of loads in the network are inductive. In this regard, LED lighting behaves as some type of reactive power compensator. Analysis of power measurement results of LED lamps showed unusual curve where in 5 of 7 days power peaks appeared as a result of huge inrush current. It can be assumed that LED driver does not have an inrush current limiter (e.g. NTC) ACKNOWLEDGEMENTS Authors want to thanks to the Municipality of Gola for their permission to perform measurments of power quality indices on public lighting system. REFERENCES [1] J. Perko, Comparison of Grid Rules and Standard HRN EN 50160, Elektrotehničko društvo Zagreb, E-biblioteka, Zagreb, 2010. (in Croatian). [2] European Standard, Voltage Characteristics of Electricity Supplied by Public Distribution Networks (EN 50160), Brussels, Belgium, 2007. [3] H. Markiewich, A. Klajn, Voltage Disturbances, Standard EN 50160, Guide, European Coper Institute, Wroclaw University of Technology and Copper Development Association, 2014, Wroclaw, 2014. [4] F. Outferdine et al., "Feasibility of Substitution of the Conventional Street Lighting Installation by the Photovoltaic Case Study on a Municipality in Agadir in Morocco," International Journal of Electrical and Computer Engineering (IJECE), Vol 7, No 5: October 2017 [5] I. Ramljak, J. Perko, M. Žnidarec, “Voltage Flickers as Voltage Quality Problem in Industrial Sector”, The International Symposium on Power Quality, Teslić, Bosnia and Herzegovina, 2017 [6] M. Wasif Umar et al.,” PWM Dimming for High Brightness LED Based Automotive Lighting Applications”, International Journal of Electrical and Computer Engineering (IJECE), Vol 7, No 5. October 2017 [7] Ž. Novinc, Power Quality, Graphis, Zagreb, Croatia, 2006. (in Croatian) [8] Z. Klaić, Mesurement and Analysis of Power Quality in Distribution Network According to European Standard EN 50160, Master work, Osijek, Croatia, 2006. (in Croatian) BIOGRAPHIES OF AUTHORS Jurica Perko, MEng (IEEE M91246004;2011) was born in Djakovo on July 13, 1988. He obtained his BSc degree (2010) and MSc degree (2012) in electrical engineering at the Faculty of Electrical Engineering, University of Josip Juraj Strossmayer Osijek and currently attending PhD studies at Faculty of Electrical Engineering, Computer Science and Information Technology Osijek. Currently he is an Energy Expert at Regional Energy Agency North in Koprivnica, Croatia. His main interests are renewable energy sources, energy efficiency, public lighting systems and electro mobility. He has published 10 technical papers in journals and international conferences. He is a Member of IEEE PES Society, PELS Society and Smart Cities Community.
  • 8. Int J Elec & Comp Eng ISSN: 2088-8708  Comparative Analysis of Power Quality Indices for Different Lighting Techniogies in …. (Jurica Perko) 887 Srete Nikolovski, PhD.El.Eng. (IEEE M’1995, SM’2005) was born in Belgrade on October 1, 1954. He obtained his BSc degree (1978) and MSc degree (1989), in electrical engineering at the Faculty of Electrical Engineering, University of Belgrade and his PhD degree from the Faculty of Electrical and Computing Engineering, University of Zagreb, Croatia in 1993. Currently he is a Full Professor at Power Engineering Department at Faculty of Electrical Engineering, J.J. Strossmayer University in Osijek, Croatia. His main interests are power system protection, power system modeling, simulation and reliability. He has published 180 technical papers in journals and international conferences. He is a Senior Member of IEEE Reliability Society, PES Society and the member of Croatian National Committee of CIGRE Ljubomir Majdandžić PhD.Mech.Eng, was born on July 4, 1960 in Ivanjska at Banja Luka. He graduated two post studies: in 1999 at the Faculty of Mechanical Engineering and Naval Architecture University of Zagreb and in 2001 at the Faculty of Economics in Zagreb. From 2001 to 2003 working on a PhD Thesis at the Fraunhofer Institute for Solar Energy, Department of electric power systems, in Freiburg, Germany. He obtained his PhD degree at the Faculty of Electrical Engineering and Computing in Zagreb in 2004. He was associate professor at Faculty of Electrical Engineering, University of Osijek. Author is of 64 scientific and professional papers in the field of energy, renewable energy and sustainable development. He is a member of the International Solar Energy Society (ISES), the German Society for Solar and the Croatian Energy Association. Now he is senior advisor at Environmental Protection and Energy Efficiency Fund, Zagreb, Croatia