Webinar mdc i_kan_20170417 final
1. ICP DAS Co., LTD. www.icpdas.com
International Webinar
MDC-700 Series
iKAN Series
ICPDAS Co., Ltd.
Michael Chen & Kevin Ho
E-mail: michael_chen@icpdas.com
: kevin@icpdas.com
2017/04/19
2. ICP DAS Co., LTD. www.icpdas.com
What is MDC-700 Series?
Why need MDC-700 Series
About MDC-700 Series?
MDC Selling Points
Applica>on Story
Page 2
MDC-700 Series
3. ICP DAS Co., LTD. www.icpdas.com
What is MDC-700 Series?
Page 3
5. ICP DAS Co., LTD. www.icpdas.com
MDC = Modbus Data Concentrator
5
With MDC Without MDC
6. ICP DAS Co., LTD. www.icpdas.com
Why need MDC-700 Series?
Page 6
7. ICP DAS Co., LTD. www.icpdas.com
• Most of meters only support low speed serial interface (RS-232/485)
• Discontinuous data collecting makes communication less efficient
• Upgrading CPU and RAM size does not help
Traditional System
Data #4 Data #5 Data #6
Data #1 Data #2 Data #3
Low Speed
RS-485
Page 7
8. ICP DAS Co., LTD. www.icpdas.com
• Can I get data via the Ethernet?
• What if I want to share the data to 2nd set of SCADA?
• Can I get data in more efficient way?
What if I need more?
Page 8
9. ICP DAS Co., LTD. www.icpdas.com
Does Gateway Solve the problem ? No.
tGW-715
High Speed
Ethernet
uPAC-7186EX-MTCP
Data #1 Data #2 Data #3
1
4
3
2
Low Speed
RS-485
Page 9
10. ICP DAS Co., LTD. www.icpdas.com
Does MDC Solve the Problem ? Yes
Page 10
High Speed
Ethernet
MDC-711
MDC-711
1
2
Data #1 Data #2 Data #3
B
A
Low Speed
RS-485
11. ICP DAS Co., LTD. www.icpdas.com
About MDC-700 Series
Page 11
12. ICP DAS Co., LTD. www.icpdas.com
MDC System Diagram
Page 12
13. ICP DAS Co., LTD. www.icpdas.com
Model COM Port Ethernet
RS-232 RS-485 Protocol Port Speed Protocol
MDC-711 1 1 Modbus/RTU
Master/Slave
1 10/100M Modbus/TCP
Slave MDC-714 1 4
MDC-741 4 1
MDC 700 Series
Page 13
14. ICP DAS Co., LTD. www.icpdas.com
• MDC-700-FD series
– Event log for
• MDC Power Restart
• Communication Timeout
• Communication Recovery
– Storage Capability
• One log file (yyyymmdd.csv) for one day
• Maximum. 30 log files
New member coming soon in Q3
Page 14
15. ICP DAS Co., LTD. www.icpdas.com
Web-based User Interface
Page 15
16. ICP DAS Co., LTD. www.icpdas.com
• Easy to know the register mapping
• Easy to debug
– Get information on the web page
– Get information through Modbus/TCP
Web-based User Interface
Page 16
17. ICP DAS Co., LTD. www.icpdas.com
• PollDelay: Some low speed device can not accept frequent request
• #: Defines the type of polling definition
– (*): valid definition
– (-): disabled definition. The register space will be reserved.
– (Empty): null definition
Easy to Configure (.CSV file)
Page 17
18. ICP DAS Co., LTD. www.icpdas.com
• Config.csv can be import/export
Easy to Configure (.CSV file)
Page 18
20. ICP DAS Co., LTD. www.icpdas.com
Great Capability
Max. 240 definitions
Page 20
21. ICP DAS Co., LTD. www.icpdas.com
• 32 Devices on Each RS-485
• Allows Max. of 8 Modbus/TCP Masters
• COM port can be Modbus/RTU Master or
Slave
• MDC-711: 1x RS-232, 1x RS-485
• MDC-714: 1x RS-232, 4x RS-485
• MDC-741: 4x RS-232, 1x RS-485
Good Expansion Flexibility
Page 21
22. ICP DAS Co., LTD. www.icpdas.com
• Make register continuous
Boost Communication (#1)
#1 #2
#3 #4
#1 #2 #3 #4
Page 22
23. ICP DAS Co., LTD. www.icpdas.com
• Make write command (for AO, DO) as first priority
– Write commands will be forced to the Modbus/RTU
devices within 300 ms
– baudrate=115200 bps
– Delay betweenPoll=50ms
– no mater how many devices are connected to the same
RS-485 bus.
Boost Communication (#2)
R
5
R
4
R
3
R
2
W
1
R
1
Page 23
24. ICP DAS Co., LTD. www.icpdas.com
• MDC Method: Skip off-line device
– checks off-line devices every 10 seconds instead of every polling cycle
Boost Communication (#3)
All devices are on-line
Page 24
Time
Cycle
#1
R
1
R
2
R
3
R
4
R
5
Cycle
#2
R
1
R
2
R
3
R
4
R
5
Cycle
#3
R
1
R
2
R
3
R
4
R
5
Cycle
#4
R
1
R
2
R
3
R
4
R
5
Cycle
#5
R
1
R
2
R
3
R
4
R
5
Cycle
#1
R2
(Timeout)
Regular Polling Method
Time
R
1
R
3
R
4
R
5
Cycle
#2
R2
(Timeout)
R
1
R
3
R
4
R
5
Cycle
#3
R2
(Timeout)
R
1
R
3
R
4
R
5
Cycle
#4
R2
(Timeout)
R
1
R
3
R
4
R
5
10 seconds
Time
MDC Method
Cycle
#1
R2
(Timeout)
R
1
R
3
R
4
R
5
Cycle
#2
R
1
R
3
R
4
R
5
Cycle
#3
R
1
R
3
R
4
R
5
Cycle
#4
R
1
R
3
R
4
R
5
Cycle
#5
R
1
R
3
R
4
R
5
Cycle
#6
R
1
R
3
R
4
R
5
Cycle
#7
R2
(Timeout)
R
1
R
3
R
4
R
5
25. ICP DAS Co., LTD. www.icpdas.com
• Each COM port performs polling parallelly
Boost Communication (#4)
COM1
COM2
COM3
COM4
Page 25
R
1
R
2
R
3
R
4
R
5
R
1
R
2
R
3
R
4
R
5
R
1
R
2
R
3
R
4
R
5
R
1
R
2
R
3
R
4
R
5
27. ICP DAS Co., LTD. www.icpdas.com
Selling Points
• Web-based User Interface
• Easy to Configure
• Great Capability
• Good Expansion Flexibility
• Boost Communication
• Improve system performance and stability
Page 27
28. ICP DAS Co., LTD. www.icpdas.com
Choose MDC or Gateway?
Page 28
29. ICP DAS Co., LTD. www.icpdas.com
Application Story
Page 29
30. ICP DAS Co., LTD. www.icpdas.com
• A Factory with many Modbus/RTU devices
Application (#1)
PMC-5151
Ethernet
RS-485
PM-3133
DL-100
M-7015P x 10 pcs
SCADA system
(Office)
Factory_3F
RS-485
PM-3133
DL-100
PMC-5151
RS-485
PM-3133
DL-100
Factory_2F
LAB_1F
M-7017RMS
InduSoft
Ethernet
MDC-714
PMC-5151
tGW-715
DL-303
Page 30
31. ICP DAS Co., LTD. www.icpdas.com
• Data Shared by SCADA and HMI
Application (#2, Before)
Page 31
RS-485
Modbus /RTU
RS-485 Hub
(I-7514U)
…
…
…
…
SCADA
USB to RS-232/422/485 Converter
(I-7561)
RS-485
Modbus /RTU
USB
32. ICP DAS Co., LTD. www.icpdas.com
• Data Shared by SCADA and HMI
Application (#2, After)
HMI
(TPD-703)
RS-485
Modbus /RTU
MDC-714
Switch
(NS-205)
…
…
…
…
SCADA
Ethernet
Modbus /TCP
Page 32
33. ICP DAS Co., LTD. www.icpdas.com
More Information
http://www.icpdas.com/root/product/solutions/industrial_communication/modbus_data_concentrator/
mdc-700.html
Page 33
34. ICP DAS Co., LTD. www.icpdas.com
What is iKAN ?
Why we need it ?
About iKAN ?
How iKAN works ?
Applica>on story
iKAN Series
Page 34
35. ICP DAS Co., LTD. www.icpdas.com
What is iKAN?
Page 35
36. ICP DAS Co., LTD. www.icpdas.com
iKAN Series
Industrial Modbus LED Display
Page 36
37. ICP DAS Co., LTD. www.icpdas.com
Why we need it ?
Page 37
38. ICP DAS Co., LTD. www.icpdas.com
Need a text changeable display
The data changed frequently
– Used EEPROM to store message, may be damaged in 2 years.
Must be easy to be integrated to SCADA and PLC
– Modbus TCP/RTU protocol needed.
Page 38
39. ICP DAS Co., LTD. www.icpdas.com
About iKAN Series
Page 39
40. ICP DAS Co., LTD. www.icpdas.com
iKAN System Diagram
Page 40
41. ICP DAS Co., LTD. www.icpdas.com
• 7 Colors
• Character Sets: 16-bit Unicode or 7-bit ASCII
• Character Height: 16 cm
• Display Size & Dimensions
iKAN Hardware Features (#1)
41
Available
Will be available in Q3
42. ICP DAS Co., LTD. www.icpdas.com
• Built-in RTC
• Power Input: 110~220 VAC
iKAN Hardware Features (#2)
42
iKAN-1xx iKAN-2xx
Ethernet 1x port 2x ports ( Ethernet switch)
COM port 1x RS-232/485 1x RS-232, 2x RS-485
Digital I/O N/A 2x Dry Input (emergency buWons)
2x Open Collector Output
( to connect with alarms)
43. ICP DAS Co., LTD. www.icpdas.com
• Web-based user interface
• Message Pool
– including 64 common messages and 10 instant messages
• Data Pool
– 40 coil, 64 integer, 64 float,
allows PLC/SCADA system to write data.
• Message Style
– Unicode Multilanguage
– Combine variable data and text
• Import/Export Message Pool
• Supports the Modbus TCP/RTU slave
iKAN Software Features
43
44. ICP DAS Co., LTD. www.icpdas.com
• Web-based User Interface
Easy to Use (#1)
Page 44
45. ICP DAS Co., LTD. www.icpdas.com
• Message Pool Import/Export
Easy to Use (#2)
Œ
Page 45
57. ICP DAS Co., LTD. www.icpdas.com
iKAN Selling Points
58. ICP DAS Co., LTD. www.icpdas.com
iKAN Selling Points
• Seamless Integrate with PLC/SCADA/HMI
• Supports the Modbus TCP/RTU slave
• Web-based user interface
• Import/Export Message Pool
Easy to Use
Page 58
59. ICP DAS Co., LTD. www.icpdas.com
More Information
http://www.icpdas.com/root/product/solutions/hmi_touch_monitor/led/ikan_introduction.html
Page 59
60. ICP DAS Co., LTD. www.icpdas.com
Q & A
Thank you very much!
Email: michael_chen@icpdas.com