SFP-10G-A01-T01#171001
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 1 -
10G 1M SFP+ AOC
Specification Revision Record
Date Version Page Revision Description Prepare Approve
2020-10-08 1.0 Jiang L
All right reserved by Guilin GLsun Science and Tech Group Co., LTD. Without written permission,
any unit or individual can’t reproduce, copy or use it for any commercial purpose.
Product 10G 1M SFP+ AOC
Model SFP-10G-A01-T01
File No. SFP-10G-A01-T01#171001
Version 1.0
Issuing Date 2019-12-19
- 1 -
SFP-10G-A01-T01#171001
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 2 -
Product Description
Passive cables may require host pre-emphasis and equalization to reach at the longer lengths.
Product Feature
Passive cables may require host pre-emphasis and equalization to reach at the longer lengths.
Support hot-pluggable
Available in lengths from 1m to 50m
360 degree cable braid crimp and enhanced EMI skirt
Excellent ESD protection
Single 3.3V power supply
RoHS Compliant and Lead-Free
Compliant with SFF-8472 Rev 11.1
Compliant with SFP+ MSA: SFF-8431 Rev4.1
Regulatory Compliance
ESD to the Electrical PINs: compatible with MIL-STD-883 Method 3015
Immunity compatible with EN 61000-4-3
EMI compatible with FCC Part 15 Class B
ROHS compliant with RoHS 2.0(2015/863/EU)-amending
General Specifications
Parameter Symbol Min Typ Max Unit Ref.
Maximum Supply Voltage Vcc V -0.5 +4.0
Storage Temperature TS °C -40 +85
Operating Humidity RH % 0 85
Power Supply Voltage Vcc3 3.13 3.30 3.47 V
Power Supply Current Icc 140 mA One side
Case Operating Temperature Tc 0 +70 °C
SFP-10G-A01-T01#171001
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 3 -
Electrical Characteristics
Pin Descriptions
Pin Symbol Name Ref.
1 VeeT Transmitter Ground (Common with Receiver Ground)
2 TX Fault Transmitter Fault. LVTTL-O
3 TX Disable
Transmitter Disable. Laser output disabled on high or open.
LVTTL-I
4 SDA
2-Wire Serial Interface Data Line (Same as MOD-DEF2 in
INF-8074i). LVTTL-I/O
5 SCL
2-Wire Serial Interface Data Line (Same as MOD-DEF2 in
INF-8074i). LVTTL-I
6 Mod_ ABS Module Absent, Connect to VeeT or VeeR in Module.
7 RS0 Rate Select 0, optionally controls SFP+ module receiver LVTTL-I
8 LOS
Loss of Signal indication. Logic 0 indicates normal operation.
LVTTL-O
9 RS1
Rate Select 1, optionally controls SFP+ module transmitter.
LVTTL-I
10 VeeR Receiver Ground (Common with Transmitter Ground)
Parameter Symbol Min Typ Max Unit Ref.
Transmitter
Input differential impedance Rin 90 100 110 Ω
Differential data input swing Vin, pp 100 1000 mV
TX Disable-High Vcc –1.3 Vcc+0.3 V
TX Disable-Low Vee Vee+ 0.8 V
TX Fault-High Vcc-1.3 Vcc+0.3 V
TX Fault-Low Vee Vee+0.8 V
Receiver
Differential data input swing Vout, pp 600 800 mV
Differential data input swing Zo 90 100 110 Ω
LOS-High Vcc– 1.3 Vcc+0.3 V
LOS-Low Vee Vee+0.8 V
Notes:
1. AC coupled.
2. Into 100 ohm differential termination.
SFP-10G-A01-T01#171001
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 4 -
11 VeeR Receiver Ground (Common with Transmitter Ground)
12 RD- Receiver Inverted DATA out. AC Coupled. CML-O
13 RD+ Receiver Non-inverted DATA out. AC Coupled. CML-O
14 VeeR Receiver Ground (Common with Transmitter Ground)
15 VccR Receiver Power Supply
16 VccT Transmitter Power Supply
17 VeeT Transmitter Ground (Common with Receiver Ground)
18 TD+ Transmitter Non-Inverted DATA in. AC Coupled. CML- I
19 TD- Transmitter Inverted DATA in. AC Coupled. CML- I
20 VeeT Transmitter Ground (Common with Receiver Ground)
Pin-out of Connector Block on Host Board
SFP-10G-A01-T01#171001
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 5 -
Mechanical Specifications
Cable Mechanical Specifications Min Typical Max Units
Minimum bend radius 60 MM
Minimum bend radius within
100 mm of a module end
105 MM
Minimum bend radius within
100 mm of a module end
1.8 2.0 2.2 MM
EEPROM Information
EEPROM memory map specific data field description is as below:
SFP-10G-A01-T01#171001
Guilin GLsun Science and Tech Group Co., LTD.
Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com
- 6 -
Ordering Information
Part Number Description
SFP-10G-A01-T01
Active Optical Cable,10G,SFP+ to SFP+,
0~70℃ operating temperature,1m

More Related Content

Similar to sfp-10g-1m-active-optical-cable-171001.pdf

Similar to sfp-10g-1m-active-optical-cable-171001.pdf (20)

sfp-10g-bx40u-1270nm-1330nm-40km-bidi-optical-module-141021.pdf
sfp-10g-bx40u-1270nm-1330nm-40km-bidi-optical-module-141021.pdfsfp-10g-bx40u-1270nm-1330nm-40km-bidi-optical-module-141021.pdf
sfp-10g-bx40u-1270nm-1330nm-40km-bidi-optical-module-141021.pdf
 
sfp-10g-er-1550nm-40km-fiber-optic-transceiver-141011.pdf
sfp-10g-er-1550nm-40km-fiber-optic-transceiver-141011.pdfsfp-10g-er-1550nm-40km-fiber-optic-transceiver-141011.pdf
sfp-10g-er-1550nm-40km-fiber-optic-transceiver-141011.pdf
 
sfp-10g-er-1550nm-40km-fiber-optical-transceiver-141010.pdf
sfp-10g-er-1550nm-40km-fiber-optical-transceiver-141010.pdfsfp-10g-er-1550nm-40km-fiber-optical-transceiver-141010.pdf
sfp-10g-er-1550nm-40km-fiber-optical-transceiver-141010.pdf
 
sfp-10g-bx40d-1330nm-1270nm-40km-bidi-optical-module-141022.pdf
sfp-10g-bx40d-1330nm-1270nm-40km-bidi-optical-module-141022.pdfsfp-10g-bx40d-1330nm-1270nm-40km-bidi-optical-module-141022.pdf
sfp-10g-bx40d-1330nm-1270nm-40km-bidi-optical-module-141022.pdf
 
sfp-10g-er-1310nm-40km-optical-transceiver-141012.pdf
sfp-10g-er-1310nm-40km-optical-transceiver-141012.pdfsfp-10g-er-1310nm-40km-optical-transceiver-141012.pdf
sfp-10g-er-1310nm-40km-optical-transceiver-141012.pdf
 
sfp28-25g-sr-850nm-100m-fiber-optic-transceiver-131001.pdf
sfp28-25g-sr-850nm-100m-fiber-optic-transceiver-131001.pdfsfp28-25g-sr-850nm-100m-fiber-optic-transceiver-131001.pdf
sfp28-25g-sr-850nm-100m-fiber-optic-transceiver-131001.pdf
 
spf-1g-bx20d-1490nm-1310nm-20km-bidi-fiber-optical-module-151016.pdf
spf-1g-bx20d-1490nm-1310nm-20km-bidi-fiber-optical-module-151016.pdfspf-1g-bx20d-1490nm-1310nm-20km-bidi-fiber-optical-module-151016.pdf
spf-1g-bx20d-1490nm-1310nm-20km-bidi-fiber-optical-module-151016.pdf
 
sfp-1g-sx-850nm-fiber-optic-transceiver-151001.pdf
sfp-1g-sx-850nm-fiber-optic-transceiver-151001.pdfsfp-1g-sx-850nm-fiber-optic-transceiver-151001.pdf
sfp-1g-sx-850nm-fiber-optic-transceiver-151001.pdf
 
sfp-1g-bx10u-1310nm-1490nm-10km-bidi-fiber-transceiver-151108-T03.pdf
sfp-1g-bx10u-1310nm-1490nm-10km-bidi-fiber-transceiver-151108-T03.pdfsfp-1g-bx10u-1310nm-1490nm-10km-bidi-fiber-transceiver-151108-T03.pdf
sfp-1g-bx10u-1310nm-1490nm-10km-bidi-fiber-transceiver-151108-T03.pdf
 
sfp-1g-cwdm-1330nm-80km-fiber-optical-module-151044.pdf
sfp-1g-cwdm-1330nm-80km-fiber-optical-module-151044.pdfsfp-1g-cwdm-1330nm-80km-fiber-optical-module-151044.pdf
sfp-1g-cwdm-1330nm-80km-fiber-optical-module-151044.pdf
 
sfp-2.5g-sx-850nm-550m-optical-transceiver-151009.pdf
sfp-2.5g-sx-850nm-550m-optical-transceiver-151009.pdfsfp-2.5g-sx-850nm-550m-optical-transceiver-151009.pdf
sfp-2.5g-sx-850nm-550m-optical-transceiver-151009.pdf
 
sfp-10g-sr-850nm-300m-transceiver-module-141001.pdf
sfp-10g-sr-850nm-300m-transceiver-module-141001.pdfsfp-10g-sr-850nm-300m-transceiver-module-141001.pdf
sfp-10g-sr-850nm-300m-transceiver-module-141001.pdf
 
xfp-10g-zr-100km-1550nm-transceiver-module-141158.pdf
xfp-10g-zr-100km-1550nm-transceiver-module-141158.pdfxfp-10g-zr-100km-1550nm-transceiver-module-141158.pdf
xfp-10g-zr-100km-1550nm-transceiver-module-141158.pdf
 
sfp-25g-cwdm-1310nm-10km-fiber-optical-module-131007.pdf
sfp-25g-cwdm-1310nm-10km-fiber-optical-module-131007.pdfsfp-25g-cwdm-1310nm-10km-fiber-optical-module-131007.pdf
sfp-25g-cwdm-1310nm-10km-fiber-optical-module-131007.pdf
 
sfp-25g-cwdm-1350nm-10km-fiber-transceiver-131009.pdf
sfp-25g-cwdm-1350nm-10km-fiber-transceiver-131009.pdfsfp-25g-cwdm-1350nm-10km-fiber-transceiver-131009.pdf
sfp-25g-cwdm-1350nm-10km-fiber-transceiver-131009.pdf
 
sfp28-25g-bx10u-1270nm-1330nm-10km-bidi-optical-transceiver-131004.pdf
sfp28-25g-bx10u-1270nm-1330nm-10km-bidi-optical-transceiver-131004.pdfsfp28-25g-bx10u-1270nm-1330nm-10km-bidi-optical-transceiver-131004.pdf
sfp28-25g-bx10u-1270nm-1330nm-10km-bidi-optical-transceiver-131004.pdf
 
sfp-25g-cwdm-1270nm-10km-transceiver-module-131005.pdf
sfp-25g-cwdm-1270nm-10km-transceiver-module-131005.pdfsfp-25g-cwdm-1270nm-10km-transceiver-module-131005.pdf
sfp-25g-cwdm-1270nm-10km-transceiver-module-131005.pdf
 
sfp-1g-sx-1310nm-2km-fiber-optical-module-151011.pdf
sfp-1g-sx-1310nm-2km-fiber-optical-module-151011.pdfsfp-1g-sx-1310nm-2km-fiber-optical-module-151011.pdf
sfp-1g-sx-1310nm-2km-fiber-optical-module-151011.pdf
 
sfp-1g-bx20d-1550nm-1310nm-20km-bidi-fiber-transceiver-151109-T03.pdf
sfp-1g-bx20d-1550nm-1310nm-20km-bidi-fiber-transceiver-151109-T03.pdfsfp-1g-bx20d-1550nm-1310nm-20km-bidi-fiber-transceiver-151109-T03.pdf
sfp-1g-bx20d-1550nm-1310nm-20km-bidi-fiber-transceiver-151109-T03.pdf
 
sfp-25g-cwdm-1370nm-10km-fiber-optic-transceiver-131010.pdf
sfp-25g-cwdm-1370nm-10km-fiber-optic-transceiver-131010.pdfsfp-25g-cwdm-1370nm-10km-fiber-optic-transceiver-131010.pdf
sfp-25g-cwdm-1370nm-10km-fiber-optic-transceiver-131010.pdf
 

More from GLsun Mall

osw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdf
osw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdfosw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdf
osw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdf
GLsun Mall
 
mems-s1-1x8-mems-optical-switch-data-sheet-540301.pdf
mems-s1-1x8-mems-optical-switch-data-sheet-540301.pdfmems-s1-1x8-mems-optical-switch-data-sheet-540301.pdf
mems-s1-1x8-mems-optical-switch-data-sheet-540301.pdf
GLsun Mall
 
mems-8x8-optic-switch-module-data-sheet-540401.pdf
mems-8x8-optic-switch-module-data-sheet-540401.pdfmems-8x8-optic-switch-module-data-sheet-540401.pdf
mems-8x8-optic-switch-module-data-sheet-540401.pdf
GLsun Mall
 

More from GLsun Mall (20)

to56-10g-dfb-laser-diode-1330nm-data-sheet-602003.pdf
to56-10g-dfb-laser-diode-1330nm-data-sheet-602003.pdfto56-10g-dfb-laser-diode-1330nm-data-sheet-602003.pdf
to56-10g-dfb-laser-diode-1330nm-data-sheet-602003.pdf
 
to56-10g-dfb-laser-diode-1310nm-data-sheet-602002.pdf
to56-10g-dfb-laser-diode-1310nm-data-sheet-602002.pdfto56-10g-dfb-laser-diode-1310nm-data-sheet-602002.pdf
to56-10g-dfb-laser-diode-1310nm-data-sheet-602002.pdf
 
to56-2.5g-dfb-laser-diode-1310nm-data-sheet-602001.pdf
to56-2.5g-dfb-laser-diode-1310nm-data-sheet-602001.pdfto56-2.5g-dfb-laser-diode-1310nm-data-sheet-602001.pdf
to56-2.5g-dfb-laser-diode-1310nm-data-sheet-602001.pdf
 
osw-2x4-cascade-optical-switch-data-sheet-550201.pdf
osw-2x4-cascade-optical-switch-data-sheet-550201.pdfosw-2x4-cascade-optical-switch-data-sheet-550201.pdf
osw-2x4-cascade-optical-switch-data-sheet-550201.pdf
 
osw-1x16-cascade-optical-switch-data-sheet-550101.pdf
osw-1x16-cascade-optical-switch-data-sheet-550101.pdfosw-1x16-cascade-optical-switch-data-sheet-550101.pdf
osw-1x16-cascade-optical-switch-data-sheet-550101.pdf
 
osw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdf
osw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdfosw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdf
osw-1x8-multi-channel-rotary-optical-switch-data-sheet-550401.pdf
 
mems-s1-1x8-mems-optical-switch-data-sheet-540301.pdf
mems-s1-1x8-mems-optical-switch-data-sheet-540301.pdfmems-s1-1x8-mems-optical-switch-data-sheet-540301.pdf
mems-s1-1x8-mems-optical-switch-data-sheet-540301.pdf
 
mems-8x8-optic-switch-module-data-sheet-540401.pdf
mems-8x8-optic-switch-module-data-sheet-540401.pdfmems-8x8-optic-switch-module-data-sheet-540401.pdf
mems-8x8-optic-switch-module-data-sheet-540401.pdf
 
fsw-2x2b-micro-optical-switch-510401.doc
fsw-2x2b-micro-optical-switch-510401.docfsw-2x2b-micro-optical-switch-510401.doc
fsw-2x2b-micro-optical-switch-510401.doc
 
fsw-2x2a-micro-optical-switch-510901.doc
fsw-2x2a-micro-optical-switch-510901.docfsw-2x2a-micro-optical-switch-510901.doc
fsw-2x2a-micro-optical-switch-510901.doc
 
fsw-1x2h-micro-optical-switch-510301.doc
fsw-1x2h-micro-optical-switch-510301.docfsw-1x2h-micro-optical-switch-510301.doc
fsw-1x2h-micro-optical-switch-510301.doc
 
fsw-1x2-micro-fiber-optical-switch-510201.doc
fsw-1x2-micro-fiber-optical-switch-510201.docfsw-1x2-micro-fiber-optical-switch-510201.doc
fsw-1x2-micro-fiber-optical-switch-510201.doc
 
fsw-1x1-micro-fiber-optical-switch-510101.doc
fsw-1x1-micro-fiber-optical-switch-510101.docfsw-1x1-micro-fiber-optical-switch-510101.doc
fsw-1x1-micro-fiber-optical-switch-510101.doc
 
multi-channel-optical-link-selector-data-sheet-580501.pdf
multi-channel-optical-link-selector-data-sheet-580501.pdfmulti-channel-optical-link-selector-data-sheet-580501.pdf
multi-channel-optical-link-selector-data-sheet-580501.pdf
 
2u-d1x32-rackmount-optical-switch-data-sheet-580202.pdf
2u-d1x32-rackmount-optical-switch-data-sheet-580202.pdf2u-d1x32-rackmount-optical-switch-data-sheet-580202.pdf
2u-d1x32-rackmount-optical-switch-data-sheet-580202.pdf
 
2u-1x64-rackmount-optical-switch-data-sheet-580201.pdf
2u-1x64-rackmount-optical-switch-data-sheet-580201.pdf2u-1x64-rackmount-optical-switch-data-sheet-580201.pdf
2u-1x64-rackmount-optical-switch-data-sheet-580201.pdf
 
1u-n-1x1-optical-switch-data-sheet-580601.pdf
1u-n-1x1-optical-switch-data-sheet-580601.pdf1u-n-1x1-optical-switch-data-sheet-580601.pdf
1u-n-1x1-optical-switch-data-sheet-580601.pdf
 
1u-d1x8-rackmount-optical-switch-data-sheet-580103.pdf
1u-d1x8-rackmount-optical-switch-data-sheet-580103.pdf1u-d1x8-rackmount-optical-switch-data-sheet-580103.pdf
1u-d1x8-rackmount-optical-switch-data-sheet-580103.pdf
 
1u-1x16-rack-mounted-optical-switch-data-sheet-580102.pdf
1u-1x16-rack-mounted-optical-switch-data-sheet-580102.pdf1u-1x16-rack-mounted-optical-switch-data-sheet-580102.pdf
1u-1x16-rack-mounted-optical-switch-data-sheet-580102.pdf
 
1u-1x8-rack-optical-switch-data-sheet-580101.pdf
1u-1x8-rack-optical-switch-data-sheet-580101.pdf1u-1x8-rack-optical-switch-data-sheet-580101.pdf
1u-1x8-rack-optical-switch-data-sheet-580101.pdf
 

Recently uploaded

Breaking Down the Flutterwave Scandal What You Need to Know.pdf
Breaking Down the Flutterwave Scandal What You Need to Know.pdfBreaking Down the Flutterwave Scandal What You Need to Know.pdf
Breaking Down the Flutterwave Scandal What You Need to Know.pdf
UK Journal
 
Easier, Faster, and More Powerful – Alles Neu macht der Mai -Wir durchleuchte...
Easier, Faster, and More Powerful – Alles Neu macht der Mai -Wir durchleuchte...Easier, Faster, and More Powerful – Alles Neu macht der Mai -Wir durchleuchte...
Easier, Faster, and More Powerful – Alles Neu macht der Mai -Wir durchleuchte...
panagenda
 

Recently uploaded (20)

ERP Contender Series: Acumatica vs. Sage Intacct
ERP Contender Series: Acumatica vs. Sage IntacctERP Contender Series: Acumatica vs. Sage Intacct
ERP Contender Series: Acumatica vs. Sage Intacct
 
Event-Driven Architecture Masterclass: Engineering a Robust, High-performance...
Event-Driven Architecture Masterclass: Engineering a Robust, High-performance...Event-Driven Architecture Masterclass: Engineering a Robust, High-performance...
Event-Driven Architecture Masterclass: Engineering a Robust, High-performance...
 
Google I/O Extended 2024 Warsaw
Google I/O Extended 2024 WarsawGoogle I/O Extended 2024 Warsaw
Google I/O Extended 2024 Warsaw
 
Breaking Down the Flutterwave Scandal What You Need to Know.pdf
Breaking Down the Flutterwave Scandal What You Need to Know.pdfBreaking Down the Flutterwave Scandal What You Need to Know.pdf
Breaking Down the Flutterwave Scandal What You Need to Know.pdf
 
Easier, Faster, and More Powerful – Notes Document Properties Reimagined
Easier, Faster, and More Powerful – Notes Document Properties ReimaginedEasier, Faster, and More Powerful – Notes Document Properties Reimagined
Easier, Faster, and More Powerful – Notes Document Properties Reimagined
 
Easier, Faster, and More Powerful – Alles Neu macht der Mai -Wir durchleuchte...
Easier, Faster, and More Powerful – Alles Neu macht der Mai -Wir durchleuchte...Easier, Faster, and More Powerful – Alles Neu macht der Mai -Wir durchleuchte...
Easier, Faster, and More Powerful – Alles Neu macht der Mai -Wir durchleuchte...
 
Event-Driven Architecture Masterclass: Challenges in Stream Processing
Event-Driven Architecture Masterclass: Challenges in Stream ProcessingEvent-Driven Architecture Masterclass: Challenges in Stream Processing
Event-Driven Architecture Masterclass: Challenges in Stream Processing
 
FDO for Camera, Sensor and Networking Device – Commercial Solutions from VinC...
FDO for Camera, Sensor and Networking Device – Commercial Solutions from VinC...FDO for Camera, Sensor and Networking Device – Commercial Solutions from VinC...
FDO for Camera, Sensor and Networking Device – Commercial Solutions from VinC...
 
Choosing the Right FDO Deployment Model for Your Application _ Geoffrey at In...
Choosing the Right FDO Deployment Model for Your Application _ Geoffrey at In...Choosing the Right FDO Deployment Model for Your Application _ Geoffrey at In...
Choosing the Right FDO Deployment Model for Your Application _ Geoffrey at In...
 
Microsoft CSP Briefing Pre-Engagement - Questionnaire
Microsoft CSP Briefing Pre-Engagement - QuestionnaireMicrosoft CSP Briefing Pre-Engagement - Questionnaire
Microsoft CSP Briefing Pre-Engagement - Questionnaire
 
Introduction to FIDO Authentication and Passkeys.pptx
Introduction to FIDO Authentication and Passkeys.pptxIntroduction to FIDO Authentication and Passkeys.pptx
Introduction to FIDO Authentication and Passkeys.pptx
 
WebAssembly is Key to Better LLM Performance
WebAssembly is Key to Better LLM PerformanceWebAssembly is Key to Better LLM Performance
WebAssembly is Key to Better LLM Performance
 
WebRTC and SIP not just audio and video @ OpenSIPS 2024
WebRTC and SIP not just audio and video @ OpenSIPS 2024WebRTC and SIP not just audio and video @ OpenSIPS 2024
WebRTC and SIP not just audio and video @ OpenSIPS 2024
 
How Red Hat Uses FDO in Device Lifecycle _ Costin and Vitaliy at Red Hat.pdf
How Red Hat Uses FDO in Device Lifecycle _ Costin and Vitaliy at Red Hat.pdfHow Red Hat Uses FDO in Device Lifecycle _ Costin and Vitaliy at Red Hat.pdf
How Red Hat Uses FDO in Device Lifecycle _ Costin and Vitaliy at Red Hat.pdf
 
How we scaled to 80K users by doing nothing!.pdf
How we scaled to 80K users by doing nothing!.pdfHow we scaled to 80K users by doing nothing!.pdf
How we scaled to 80K users by doing nothing!.pdf
 
AI mind or machine power point presentation
AI mind or machine power point presentationAI mind or machine power point presentation
AI mind or machine power point presentation
 
Collecting & Temporal Analysis of Behavioral Web Data - Tales From The Inside
Collecting & Temporal Analysis of Behavioral Web Data - Tales From The InsideCollecting & Temporal Analysis of Behavioral Web Data - Tales From The Inside
Collecting & Temporal Analysis of Behavioral Web Data - Tales From The Inside
 
Introduction to FDO and How It works Applications _ Richard at FIDO Alliance.pdf
Introduction to FDO and How It works Applications _ Richard at FIDO Alliance.pdfIntroduction to FDO and How It works Applications _ Richard at FIDO Alliance.pdf
Introduction to FDO and How It works Applications _ Richard at FIDO Alliance.pdf
 
Human Expert Website Manual WCAG 2.0 2.1 2.2 Audit - Digital Accessibility Au...
Human Expert Website Manual WCAG 2.0 2.1 2.2 Audit - Digital Accessibility Au...Human Expert Website Manual WCAG 2.0 2.1 2.2 Audit - Digital Accessibility Au...
Human Expert Website Manual WCAG 2.0 2.1 2.2 Audit - Digital Accessibility Au...
 
Design Guidelines for Passkeys 2024.pptx
Design Guidelines for Passkeys 2024.pptxDesign Guidelines for Passkeys 2024.pptx
Design Guidelines for Passkeys 2024.pptx
 

sfp-10g-1m-active-optical-cable-171001.pdf

  • 1. SFP-10G-A01-T01#171001 Guilin GLsun Science and Tech Group Co., LTD. Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com - 1 - 10G 1M SFP+ AOC Specification Revision Record Date Version Page Revision Description Prepare Approve 2020-10-08 1.0 Jiang L All right reserved by Guilin GLsun Science and Tech Group Co., LTD. Without written permission, any unit or individual can’t reproduce, copy or use it for any commercial purpose. Product 10G 1M SFP+ AOC Model SFP-10G-A01-T01 File No. SFP-10G-A01-T01#171001 Version 1.0 Issuing Date 2019-12-19 - 1 -
  • 2. SFP-10G-A01-T01#171001 Guilin GLsun Science and Tech Group Co., LTD. Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com - 2 - Product Description Passive cables may require host pre-emphasis and equalization to reach at the longer lengths. Product Feature Passive cables may require host pre-emphasis and equalization to reach at the longer lengths. Support hot-pluggable Available in lengths from 1m to 50m 360 degree cable braid crimp and enhanced EMI skirt Excellent ESD protection Single 3.3V power supply RoHS Compliant and Lead-Free Compliant with SFF-8472 Rev 11.1 Compliant with SFP+ MSA: SFF-8431 Rev4.1 Regulatory Compliance ESD to the Electrical PINs: compatible with MIL-STD-883 Method 3015 Immunity compatible with EN 61000-4-3 EMI compatible with FCC Part 15 Class B ROHS compliant with RoHS 2.0(2015/863/EU)-amending General Specifications Parameter Symbol Min Typ Max Unit Ref. Maximum Supply Voltage Vcc V -0.5 +4.0 Storage Temperature TS °C -40 +85 Operating Humidity RH % 0 85 Power Supply Voltage Vcc3 3.13 3.30 3.47 V Power Supply Current Icc 140 mA One side Case Operating Temperature Tc 0 +70 °C
  • 3. SFP-10G-A01-T01#171001 Guilin GLsun Science and Tech Group Co., LTD. Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com - 3 - Electrical Characteristics Pin Descriptions Pin Symbol Name Ref. 1 VeeT Transmitter Ground (Common with Receiver Ground) 2 TX Fault Transmitter Fault. LVTTL-O 3 TX Disable Transmitter Disable. Laser output disabled on high or open. LVTTL-I 4 SDA 2-Wire Serial Interface Data Line (Same as MOD-DEF2 in INF-8074i). LVTTL-I/O 5 SCL 2-Wire Serial Interface Data Line (Same as MOD-DEF2 in INF-8074i). LVTTL-I 6 Mod_ ABS Module Absent, Connect to VeeT or VeeR in Module. 7 RS0 Rate Select 0, optionally controls SFP+ module receiver LVTTL-I 8 LOS Loss of Signal indication. Logic 0 indicates normal operation. LVTTL-O 9 RS1 Rate Select 1, optionally controls SFP+ module transmitter. LVTTL-I 10 VeeR Receiver Ground (Common with Transmitter Ground) Parameter Symbol Min Typ Max Unit Ref. Transmitter Input differential impedance Rin 90 100 110 Ω Differential data input swing Vin, pp 100 1000 mV TX Disable-High Vcc –1.3 Vcc+0.3 V TX Disable-Low Vee Vee+ 0.8 V TX Fault-High Vcc-1.3 Vcc+0.3 V TX Fault-Low Vee Vee+0.8 V Receiver Differential data input swing Vout, pp 600 800 mV Differential data input swing Zo 90 100 110 Ω LOS-High Vcc– 1.3 Vcc+0.3 V LOS-Low Vee Vee+0.8 V Notes: 1. AC coupled. 2. Into 100 ohm differential termination.
  • 4. SFP-10G-A01-T01#171001 Guilin GLsun Science and Tech Group Co., LTD. Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com - 4 - 11 VeeR Receiver Ground (Common with Transmitter Ground) 12 RD- Receiver Inverted DATA out. AC Coupled. CML-O 13 RD+ Receiver Non-inverted DATA out. AC Coupled. CML-O 14 VeeR Receiver Ground (Common with Transmitter Ground) 15 VccR Receiver Power Supply 16 VccT Transmitter Power Supply 17 VeeT Transmitter Ground (Common with Receiver Ground) 18 TD+ Transmitter Non-Inverted DATA in. AC Coupled. CML- I 19 TD- Transmitter Inverted DATA in. AC Coupled. CML- I 20 VeeT Transmitter Ground (Common with Receiver Ground) Pin-out of Connector Block on Host Board
  • 5. SFP-10G-A01-T01#171001 Guilin GLsun Science and Tech Group Co., LTD. Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com - 5 - Mechanical Specifications Cable Mechanical Specifications Min Typical Max Units Minimum bend radius 60 MM Minimum bend radius within 100 mm of a module end 105 MM Minimum bend radius within 100 mm of a module end 1.8 2.0 2.2 MM EEPROM Information EEPROM memory map specific data field description is as below:
  • 6. SFP-10G-A01-T01#171001 Guilin GLsun Science and Tech Group Co., LTD. Tel: +86-773-3116006 info@glsun.com Web: www.glsun.com - 6 - Ordering Information Part Number Description SFP-10G-A01-T01 Active Optical Cable,10G,SFP+ to SFP+, 0~70℃ operating temperature,1m