Depending on battery type and application, Lead Acid batteries have a design life that can range from 5 to 20 years. That design life estimation is based on the battery being maintained in accordance with recommended practices, operating under ideal conditions and ensuring that any individual failing units are replaced before they impact the other units in the string.
However, in most installations, those conditions are seldom met, and the actual life of a battery may be closer to half of the published design life. This potential for failure has been confirmed in a number of studies over the years. In fact, in one Ponemon study into Data Center failures, the UPS Battery was responsible for over 50% of the reported outages. This data, and the uncertainty of most operating environments, confirms why battery monitoring is an essential part of maintaining today’s systems.
1. UPCOM
Battery Monitoring
Systems
Battery Monitoring Systems are smart monitoring equipment designed for batteries and battery groups used in
UPS, Data Centers, Telecom Base Stations and Solar Energy Storage units. With its built-in web server and mobile
compatible web-based monitor, UPCOM Battery Monitoring Systems can report the battery and battery group
parameters for all connected systems.
7/24Monitoring and Balancing,
Real Time Battery Alarm
* Online monitoring: voltage, temperature, impedance, charge and discharge status,
State of Charge (SOC), State of Health (SOH)
• Online Auto-Balancing function to automatically balancing charge differences
between batteries in order to keep maximum uptime and lifespan of the battery.
Centralized Monitoring
* Multi-site and large quantity battery management
* Monitor up to 5000 Batteries
All In One System + Mobile +
SMS and E-mail Alerts
* Mobile compatible system for remote management
* Multiple contact for SMS / E-mail alerts
Easy to set-up and Operate
* Easy to use Browser / Server structure
* User friendly UI
2. A.
Reduce the labor cost
and increase efficiency
on site
C.
Detect battery
failures before they
occur
UPCOM
Battery Monitoring
Systems
B.
Online monitoring
battery quality status
D.
Maintainconsistencyof
lead-acidbatterypacks
BATTERY MONITORING
SENSOR
• Individual Cell Voltage
• Individual Cell Temperature
• Individual Cell Internal Impedance
(Ohmic Value)
• Individual Cell SOC (State ofCharge)
• Individual Cell SOH (State Of Health)
• Auto-Balancing Function
BATTERY STRING
MONITORING SENSOR
• String Voltage
• String Current
• Calculate String SOC (State of Charge)
• Charging and Discharging Status of Battery
• Auto-Balancing Function
3. System Functions
Gateway
• Build-in Web Server & Database
• Max. 4 battery strings with Max. 480pcs batteries
• Alarm for individual battery & battery string failure
• Historical data & alarm data storage and analysis
• Charging & discharging curve record
• Auto-Balancing
• SMS Alarm
• 2 Ethernet Port Support: Modbus TCP/SNMP
• Supportambienttemperature and humidity
sensors
Real Time Monitoring
• Battery temperature, voltage, impedance, SOCand
SOH monitoring
• Battery string voltage, charge and discharge status
monitoring
• Temperature and humidity measurements
• Auto-Balance function for batteries
• Battery string status
• Battery sensor status
Historical Data Analysis
• Historical data analysis and archiving function for
battery voltage, temperature, impedance, SOC
and SOH
• Battery string graph for voltage and SOC
• Historical charge and discharge data for batteries
• Battery alarm and system alarms
4. Alarm
• Real time SMS and e-mail alarms for battery failures
• Set alarm values for battery voltage, temperature, impedance
• System alarms, data-base, print, and communication error etc. alarms.
Archiving and Advanced Installation Functions
• Historically archiving the accumulated data for further usage and reporting
• Adding new user and setting authority levels for users
• Naming UPS, battery string, battery amount etc. individually