Trunk cable assemblies are a key component in today’s dense fiber optic networks. Standard cable styles and connectors are stocked and can be quickly assembled for your most pressing needs. Fiber Connections assembles trunk cables with any combination of multi-fiber and single fiber connectors. The finished assemblies save time and costs at the installation site.
Custom labeling is available to make installation clear and simple. Once completed and tested, each assembly is wound onto a shipping reel for quick and easy installation. A ruggedized pulling eye, offered as an option, provides protection for the connectors and easy installation.
2. 1
MTPtoMTPAssemblies
MTP to MTP Assemblies
Fiber Count : 8, 12 or 24
Cable Type : OS2 YELLOW
OM3 TURQUOISE
OM4 HEATHER VIOLET
Connector Type Side A : 12 or 24 MTP connector
Connector Type Side B : 12 or 24 MTP connector
Cable Diameters : 3.0 mm; 8, 12 or 24 FO
3.6 mm; 12 or 24 FO
MTP to 8xLC Fan-out (1.8mm) Assemblies
Fiber Count : 8
Cable Type : OS2 YELLOW
OM3 TURQUOISE
OM4 HEATHER VIOLET
Connector Type Side A : 12 MTP connector
Connector Type Side B : 4xLC Duplex or 4xLC Uniboot
Cable Diameter : 3.0 mm; MTP Side
Fan-Out Cable Diameter: 1.8 mm; LC Side (Fan-out)
MTP to 12xLC Fan-out (1.8mm) Assemblies
Fiber Count : 12
Cable Type : OS2 YELLOW
OM3 TURQUOISE
OM4 HEATHER VIOLET
Connector Type Side A : 12 MTP connector
Connector Type Side B : 6xLC Duplex or 6xLC Uniboot
Cable Diameter : 3.0 mm; MTP Side
Fan-Out Cable Diameter : 1.8 mm; LC Side (Fan-out)
MTP to 24xLC Fan-out (1.8mm) Assemblies
Fiber Count : 24
Cable Type : OS2 YELLOW
OM3 TURQUOISE
OM4 HEATHER VIOLET
Connector Type Side A : 24 MTP connector
Connector Type Side B : 12xLCDuplexor12xLCUniboot
Cable Diameter : 3.0 mm; MTP Side
Fan-Out Cable Diameter : 1.8 mm; LC Side (Fan-out)
3. 2
MTP to 8xLC Fan-out (0.9mm) Assemblies
Fiber Count : 8
Cable Type : OS2 YELLOW
OM3 TURQUOISE
OM4 HEATHER VIOLET
Connector Type Side A : 12 MTP connector
Connector Type Side B : 8x LC Simplex or4x LC Duplex
Cable Diameter : 3.0 mm; MTP Side
Fan-Out Cable Diameter : 0.9 mm; LC Side (Fan-out)
MTP to 12xLC Fan-out (0.9mm) Assemblies
Fiber Count : 12
Cable Type : OS2 YELLOW
OM3 TURQUOISE
OM4 HEATHER VIOLET
Connector Type Side A : 12 MTP connector
Connector Type Side B : 12xLCSimplexor6xLCDuplex
Cable Diameter : 3.0 mm; MTP Side
Fan-Out Cable Diameter : 0.9 mm; LC Side (Fan-out)
MTP to 24xLC Fan-out (0.9mm) Assemblies
Fiber Count : 24
Cable Type : OS2 YELLOW
OM3 TURQUOISE
OM4 HEATHER VIOLET
Connector Type Side A : 24 MTP connector
Connector Type Side B : 24xLCSimplexor12xLCDuplex
Cable Diameter : 3.0 mm; MTP Side
Fan-Out Cable Diameter : 0.9 mm; LC Side (Fan-out)
4. 3
2x8MTP 16 Fiber Breakout Assemblies
Fiber Count : 16
Cable Type : OS2 YELLOW
OM3 TURQUOISE
OM4 HEATHER VIOLET
Connector Type Side A : 2 x 8 MTP
Connector Type Side B : 2 x 8 MTP
Cable Diameter : 6.6 mm
Fan-Out Cable Diameter : 3.0 mm
4x8MTP 32 Fiber Breakout Assemblies
Fiber Count : 32
Cable Type : OS2 YELLOW
OM3 TURQUOISE
OM4 HEATHER VIOLET
Connector Type Side A : 4 x 8 MTP
Connector Type Side B : 4 x 8 MTP
Cable Diameter : 6.6 mm
Fan-Out Cable Diameter : 3.0 mm
6x8MTP 48 Fiber Breakout Assemblies
Fiber Count : 48
Cable Type : OS2 YELLOW
OM3 TURQUOISE
OM4 HEATHER VIOLET
Connector Type Side A : 6 x 8 MTP
Connector Type Side B : 6 x 8 MTP
Cable Diameter : 7.6 mm
Fan-Out Cable Diameter : 3.0 mm
8x8MTP 64 Fiber Breakout Assemblies
Fiber Count : 64
Cable Type : OS2 YELLOW
OM3 TURQUOISE
OM4 HEATHER VIOLET
Connector Type Side A : 8 x 8 MTP
Connector Type Side B : 8 x 8 MTP
Cable Diameter : 9.2 mm
Fan-Out Cable Diameter : 3.0 mm
12x8MTP 96 Fiber Breakout Assemblies
Fiber Count : 96
Cable Type : OS2 YELLOW
OM3 TURQUOISE
OM4 HEATHER VIOLET
Connector Type Side A : 12 x 8 MTP
Connector Type Side B : 12 x 8 MTP
Cable Diameter : 10.3 mm
Fan-Out Cable Diameter : 3.0 mm
5. 4
2x12MTP 24 Fiber Breakout Assemblies
Fiber Count : 24
Cable Type : OS2 YELLOW
OM3 TURQUOISE
OM4 HEATHER VIOLET
Connector Type Side A : 2 x 12 MTP
Connector Type Side B : 2 x 12 MTP
Cable Diameter : 6.6 mm
Fan-Out Cable Diameter : 3.0 mm
4x12MTP 48 Fiber Breakout Assemblies
Fiber Count : 48
Cable Type : OS2 YELLOW
OM3 TURQUOISE
OM4 HEATHER VIOLET
Connector Type Side A : 4 x 12 MTP
Connector Type Side B : 4 x 12 MTP
Cable Diameter : 6.6 mm
Fan-Out Cable Diameter : 3.0 mm
6x12MTP 72 Fiber Breakout Assemblies
Fiber Count : 72
Cable Type : OS2 YELLOW
OM3 TURQUOISE
OM4 HEATHER VIOLET
Connector Type Side A : 6 x 12 MTP
Connector Type Side B : 6 x 12 MTP
Cable Diameter : 7.6 mm
Fan-Out Cable Diameter : 3.0 mm
8x12MTP 96 Fiber Breakout Assemblies
Fiber Count : 96
Cable Type : OS2 YELLOW
OM3 TURQUOISE
OM4 HEATHER VIOLET
Connector Type Side A : 8 x 12 MTP
Connector Type Side B : 8 x 12 MTP
Cable Diameter : 9.2 mm
Fan-Out Cable Diameter : 3.0 mm
12x12MTP 144 Fiber Breakout Assemblies
Fiber Count : 144
Cable Type : OS2 YELLOW
OM3 TURQUOISE
OM4 HEATHER VIOLET
Connector Type Side A : 12 x 12 MTP
Connector Type Side B : 12 x 12 MTP
Cable Diameter : 10.3 mm
Fan-Out Cable Diameter : 3.0 mm
6. 5
2x24MTP 48 Fiber Breakout Assemblies
Fiber Count : 48
Cable Type : OS2 YELLOW
OM3 TURQUOISE
OM4 HEATHER VIOLET
Connector Type Side A : 2 x 24 MTP
Connector Type Side B : 2 x 24 MTP
Cable Diameter :
Fan-Out Cable Diameter :
9.3mm
3.0mm
4x24MTP 96 Fiber Breakout Assemblies
Fiber Count : 96
Cable Type : OS2 YELLOW
OM3 TURQUOISE
OM4 HEATHER VIOLET
Connector Type Side A : 4 x 24 MTP
Connector Type Side B : 4 x 24 MTP
Cable Diameter :
Fan-Out Cable Diameter :
9.3mm
3.0mm
6x24MTP 144 Fiber Breakout Assemblies
Fiber Count : 144
Cable Type : OS2 YELLOW
OM3 TURQUOISE
OM4 HEATHER VIOLET
Connector Type Side A : 6 x 24 MTP
Connector Type Side B : 6 x 24 MTP
Cable Diameter :
Fan-Out Cable Diameter :
11.0 mm
3.0 mm
12x24MTP 288 Fiber Breakout Assemblies
Fiber Count : 288
Cable Type : OS2 YELLOW
OM3 TURQUOISE
OM4 HEATHER VIOLET
Connector Type Side A : 12 x 24 MTP
Connector Type Side B : 12 x 24 MTP
Cable Diameter :
Fan-Out Cable Diameter :
13.5 mm
3.0 mm
7. 6
Order Coding Assembly Type Coding
Assembly Type Coding
Cable Construction Coding
Connector Coding
MTPSf : MTP, Standard ,Female
MTPSm : MTP, Standard ,Male
MTPEf : MTP, Elite ,Female
MTPEm : MTP, Elite ,Male
XXMSf : 02/04/06/12MTP,Standard ,Female
XXMSm : 02/04/06/12MTP,Standard,Male
XXMEf : 02/04/06/12 MTP, Elite ,Female
XXMEm : 02/04/06/12 MTP,Elite ,Male
04LCD: 4 LC Duplex ( 8xLC)
06LCD: 6 LC duplex ( 12xLC)
12LCD: 12 LC duplex ( 24xLC)
08LCS : 8 LCSimplex
12LCS : 12 LC Simplex
24LCS : 24 LC Simplex
Fiber Coding
A2 : Single Mode 9/125 (OS2)
M3 : Multi Mode 50/125(OM3)
M4 : Multi Mode 50/125(OM4)
MC : MTP to MTPAssemblies
FC : MTP to LC Assemblies with Fan-out
HC : MTP to LC Assemblies 0.9mm tubes
TR : MTP Trunk Assemblies
BR : MTP to MTP Breakout Assemblies
Simplex Cables
C36/NN: 12For24F;3.6mmCable
C30/NN: 12For24F;3.0mmCable
Hybrid Cables
C09/NN: 8F,12F or 24F; 0.9 mm Colored Tubes
Breakout Cables
C6X/NN : 8Fx2,8Fx4,12Fx2,12Fx4 breakout cables
C7XNN : 8Fx6,12Fx6 breakoutcables
C9X/NN : 8Fx8,12Fx8,24Fx2,24Fx4 breakout cables
C10X/N: 12Fx12 breakout cables
C11X/N: 24Fx6 breakout cables
C13X/N: 24Fx12 breakout cables
Fanout Cables
C30/09: 8F,12For 24F;3.0 mm/0.9 mmCable
C30/20: 8F,12For 24F;3.0 mm/2.0 mmCable
C36/09: 8F,12For 24F;3.6 mm/0.9 mmCable
C36/20: 8F,12For24F;3.6 mm/2.0 mmCable
Connector Types & Performance
AssemblyType
FiberCount
SideAConnector
SideBConnector
FiberType
Lengthinmeter
CableConstruction
Wiring
MC
FC
HC
TR
BR
08
12
24
32
48
64
96
144
288
MTPEf
MTPSf
MTPEm
MTPSm
04LCD
06LCD
12LCD
08LCS
12LCS
24LCS
MTPEf
MTPSf
MTPEm
MTPSm
XX MSf
XX MSm
XX ME
XX MEm
04LCD
06LCD
12LCD
08LCS
12LCS
24LCS
M3
M4
A2
XX.X C36/NN
C30/NN
C09/NN
C6X/NN
C7X/NN
C9X/NN
C10X/N
C11X/N
C13X/N
C30/09
C30/20
C36/09
C36/20
A
B
C
Connector Mating IL Average IL Max Returnt
Loss
MTPEx (MM) ,Elite 0.10 dB 0.35 dB >20 dB
MTPEx (SM), Elite 0.10 dB 0.35 dB >60 dB
>60 dB-APC 8º
MTPSx (MM) ,Standard 0.20 dB 0.60 dB >20 dB
MTPSx (SM), Standard 0.25 dB 0.75 dB >60 dB
>60 dB-APC 8º
LC-UPC (MM) 0.15 dB 0.35 dB >35 dB
LC-UPC (SM) 0.15 dB 0.35 dB >50 dB
>60 dB-APC 8º
8. 7
Polarity & Positioning
1 2 3 4 5 6 7 8 9 10 11 12
1 12 A
B
1 12
12 11 10 9 8 7 6 5 4 3 2 1
1 2 3 4 5 6 7 8 9 10 11 12
1 12 A
B
12 1
Side-A Key-Up
1 2 3 4 5 6 7 8 9 10 11 12
P1 to P1 Side-B Key-Down
1 12
13 24
1 2 3 4 5 6 7 8 9 10 11 12
A1
B2
1 2 3 4 5 6 7 8 9 10 11 12
131415161718192021222324
24 13
12 1
Side-A Key-Up Side-B Key-Down
1 2 3 4 5 6 7 8 9 10 11 12
A1
B1
Side-A Key-Up
131415161718192021222324
131415161718192021222324 Side-B Key-Down
24 13
12 1
1 12
13 24
Type A “Straight Through” Type A “Straight Through”
Type B “Cross” Type B “Cross”
Switch Array Patch
Cord MPO Adapter Breakout Cable MPO Adapter Array Patch
Cord Switch
A Rx
Tx
Type B Type A Type A Type A Type A Rx
Tx
B Rx
Tx
Type B Type B Type B Type B Type B Rx
Tx
C Rx
Tx
Type B Type A Type C Type A Type C Rx
Tx
Method
Connectivity
12 Fibers 24 Fibers
A B A1 B1
A2 B2
A2
B1
13 14 15 16 17 18 19 20 21 22 23 24
A B
A1
A2
B1
B2
12 11 10 9 8 7 6 5 4 3 5 1
Side-A Key-Up P1 to P12 Side-B Key-Up Side-A Key-Up 131415161718192021222324
A2
B2
242322212019181716151413
Side-B Key-Up
B A1 B1
A2 B2
A2
B2
1 2 3 4 5 6 7 8 9 10 11 12
Connectivity
Method
Switch Duplex Patch
Cord
Cassette Cassette
Breakout cable Duplex Patch
Cord Switch
Duplex MPO
Adapter
MPO
Adapter Duplex
A Rx
Tx A to B Multiple
Ports Type A Type A Type A Switch A to A Rx
Tx
B Rx
Tx A to B Multiple
Ports Type B Type B Type B Switch A to B Rx
Tx
C Rx
Tx A to B Multiple
Ports Type A Type C Type A Switch A to B Rx
Tx
Type C “Cross Pair”Type C “Cross Pair”
1 2 3 4 5 6 7 8 9 10 11 12
1 12 A
B
12 1
A
Side-A Key-Up
2 1 4 3 6 5 8 7 10 9 12 11
P1 to P2
Side-B Key-Down
1 2 3 4 5 6 7 8 9 10 11 12
A1
B1
1 12
13 24
1 12
13 24