1. DHAVAL N. BHATT
50, SONIYA NAGAR, Opp. PANCHVATI, GORWA, REFINERY ROAD, BARODA-390016.
dhaval_bhatt50@yahoo.co.in M: +91-9925840102
________________________________________________________________________
OBJECTIVE:
With my engineering qualification I am looking forward for a challenging as well as rewarding career
to enhance my own productivity at the same time achieving the organization objectives with
teamwork.
SYNOPSIS:
• Total 8 years of working experience of Commissioning, Operation & Maintenance with
Different Industries and more than 7 years of working experience of varies capacity of
Thermal Power Plant, Hand on Experience of Project, Erection, Testing, Commissioning, and
Start up activity of power plant & Operation & Maintenance of Electrical Equipment.
• Preparation of Electrical Equipment specification & work on Project work with contractor.
• Operation & Maintenance of 6.6 KV/415 V HT/LT Switchgears, 66KV/11KV HT Substation,
DG Set Up to 1250 KVA , ACB,VCB, SF6 Circuit breakers, Batteries & Battery Charger Panel,
UPS.
• Maintenance of HT/LT motors, Slip-Ring, Flame proof, DC motors up to 0.5KW to11MW.
• Ability to creates & trouble shoots of control wiring as per logic of process & operation
requirement with interlocking of equipment.
• Maintenance of Power Transformer and its auxiliaries, Oil filtrations & B.D.V. test, P.P.M.
Test, IR Value Test, PI Test, Tan Delta Test. Preparation of Shut down job list & Jobs
planning & carried out all routing & corrective maintenance activity.
• Testing & Commissioning of Numerical Relay of ABB make REM-610, REF-610, REU-610,
SUE-3000 (Bus Transfer Relay), Siemens make 7SJ62, 7SJ61. Chinese relay Nanjing Nari.
• Familiar with 200 KV & 400 KV switchyard & HVDC convertor substation of 500 KV, 2500 MW
& its auxiliaries.
• Material listing for spares procurements.
• Energy Audit of Power Plant & its auxiliaries.
• Prepared report of Energy consumption, Electricity board bills, and Payment statements to
Electricity board.
JOB PROFILE:
1. ADANI POWER LTD. – 4620 MW (DEC-2010 to Till Date)
Job Responsibilities:
Presently I am working as “Associate Electrical Engineer” Looking Operation and
maintenance work in 660 MW Thermal Power Main Plant areas & 400 KV Switchyard.
Fault diagnoses by reading drawing.
Responsible for Independently Isolated/Charged EHV/HV/LV switchgears from DCS &
field operation without any major breakdown & accident.
Responsible for successfully synchronized unit with grid.
Responsible for all Preventive, Corrective and breakdown maintenance of Electrical
Equipments and individually shift handling ensuring minimum down time.
Commissioning & Testing of 6.6 KV & 415 V Bus change over scheme.
2. 2. BARODA TEXTILE EFFECTS PVT. LTD. (AUG-2008 TO DEC-2010).
Job Responsibilities:
I was worked as an “Electrical Engineer“ in Maintenance Department and Responsible for
efficient Manpower Management with Individual Shift handling ensuring minimum down time
and take necessary action to avoid repetition.
Responsible for all Preventive, Predictive, Corrective and Breakdown maintenance of
Electrical Equipment at 3MW CO-Gen Thermal Power Plant.
Responsible for Licencening with government agencies such as MGVCL, Commissioner of
Electricity for getting various approvals.
3. UNIVERSAL MEDICAP LTD. (AUG-2007 TO AUG-2008).
Job Responsibilities:
I was worked as “Electrical Engineer” Operation and maintenance work of Electrical
installations and utilities like HT/LT Switchgears, Star-Delta Starters, Transformers, Panels,
LT Motors, D.G.Set, Boiler & its auxiliaries. etc.
PERSONAL DETAILS:
DATE OF BIRTH: 26/05/1986.
MARITAL STATUS: Married.
LANGUAGE KNOWN: English, Hindi, Gujarati.
ELECTRICAL SUPERVISOR NO. : G/GS-E-002466-DEE-2010.
PASSPORT NO. : H 5826197.
SKYPE ID: dhaval_bhatt50
EDUCATION QUALIFICATION:
CERTIFICATE UNIVERSITY/ BOARD YEAR OF PASSING PERCENTAGE
S.S.C. G.S.E.B. MARCH-2001 70.00%
H.S.C. G.H.S.E.B. MARCH-2004 42.00%
DIPLOMA
ELECTRICAL
M.S.U. BARODA
(POLYTECHNIC)
JULY-2007 60.00%
OTHER QUALIFICATION:
I have participated in Bhabha Atomic Research Centre training course for Operators of High Intensity
Irradiators for Healthcare Products, organized by Indian Association for Radiation Protection (IARP).
_______________________________________________________________________________