Comparación entre consumo energético teórico y real en viviendas sociales
1. A comparison between predicted and
measured energy use in social housing
Pablo Hernández-Cruz
Juan María Hidalgo-Betanzos
Carlos García-Gáfaro
Jon Fernández-Luzuriaga
Iván Flores-Abascal
2. Who are we?
Laboratorio de Control de la
Calidad en la Edificación del
Gobierno Vasco
Basque Government
Laboratory of Quality Control of
Buildings
Vitoria - Gasteiz
Basque Country
3. Who are we?
Laboratorio de Control de la
Calidad en la Edificación del
Gobierno Vasco
Basque Government
Laboratory of Quality Control of
Buildings
Thermal Area
Guarded hot box test Paslink Test Cell
Infrared Thermography
Blower door test
Tracer gas leak test
… and more
5. 1 2 3 4 5
Introduction
Rental social housing of the
Basque Country
11 buildings
855 dwellings
PCTI 2 Buildings selected
• Detailed analysis
• Comparison with EPC
Energy
Audit
234 buildings
7700 dwellings
6. Building A Building A
• Constructed in 2010
• 126 dwellings, 385 tenants
• Centralized boilers and solar
thermal system
• Constructed in 2004
• 228 dwellings, 498 tenants
• Individual boilers
Vitoria - Gasteiz
1 2 3 4 5
Description of the buildings
7. Building A Building A
Vitoria - Gasteiz
1 2 3 4 5
Description of the buildings
D – 99,80 kWh/m²·a
D – 21,47 kg/m²·a
D – 55,10 kg/m²·a
NRPEC
CO₂ Emissions
Heating demand
E – 260,9 kWh/m²·a
E – 219,2 kg/m²·a
E – 140,3 kg/m²·a
NRPEC
CO₂ Emissions
Heating demand
8. 1 2 3 4 5
Energy balance
Building A – Centralized system
Non-Renewable Energy Consumption
Final Energy Consumption
Delivered Energy
9. 1 2 3 4 5
Energy balance
Building A – Centralized system
Monthly energy
consumption bills
Energy and volumetric
BMS counters
Estimated by project
calculations
10. 1 2 3 4 5
Energy balance
Building B – Individual boilers
Delivered Energy
Final Energy Consumption
Non-Renewable Energy Consumption
11. 1 2 3 4 5
Energy balance
Building B – Individual boilers
Annual energy
consumption data
13. 1 2 3 4 5
Results
Building B – Individual boilers
Dwelling typology Dwelling orientation
0
5000
10000
15000
20000
25000
30000
NaturalGasConsumption[kWh/a]
Natural Gas Consumption Mean Natural Gas Consumption
2 bedrooms 3 bedrooms 4 bedr.
1u 2u 3u >3u 1u 2u 3u >3u 3u >3u
0
50
100
150
200
250
300
350
North -
South
South East West East
corner
West
cornerNaturalGasConsumption[kWh/m²·a]
14. 1 2 3 4 5
Results
Building A & B vs EPC
Building A Building B
Measured EPC Measured EPC
Non-Renewable Primary Energy Consumption
(CEPNR) [kWh/m²·a]
153,7 99,8 98,3 260,9
Final Energy Consumption
(CEF) [kWh/m²·a]
139,6 89,0 82,6 219,2
Heating consumption
(CEPNR) [kWh/m²·a]
25,5 55,1 39,5 140,3
15. 1 2 3 4 5
Conclusions
✓ Building A – Centralized system low performance
Current results Next steps
• Complete energy audit
• Monitor & analyse user
behaviour and thermal
comfort
✓ High dispersion of energy consumption among users
✓ Low heating consumption when compared to EPC
Energy poverty
16. Thanks for your attention!