1. EGAS
Emissions Gas Analysis Systems
Turnkey analysis system: easy-to-use and suited
for continuous and simultaneous measurements
of THC, CH4, NmHC, NO/NOX, CO, CO2, O2, CO2
EGR and NH3
One System Measures All Engine Emissions
The EGAS System benefits from leading edge metrology and a new
modular design that offers reduced and simplified maintenance. Packed
with features the EGAS is designed to measure all emissions from all
combustion engines regardless of fuel type.
KEYBENEFITS
Positive pressure sample - no
dilution from system leaks
•
State-of-the-art Design
Heated inlet filter on primary
sample line
•
Open architecture for integration
of various analyser types
•
Open architecture for integration
of various analyser types
THC
CO
CO2
Rule 1065 & Diesel 2007 Compliant
Offering raw or dilute analysis, the EGAS system unique measurement
levels combined with high quality components and design technology
ensure complete legislation compliance.
GASESANALYSED
NOx
The EGAS system has been designed with ease and functionality in
mind; the front access panels ensure remote control of the system and its
adjoining components. It is equipped with a separate mobile sampling
trolley with built-in sample pump. Additionally, the EGAS features userfriendly networking technology for analyser control & host interface.
O2
“
The series 2M analysers are ultracompact and capable of fast and
accurate measurement
“
•
2. ANALYSERS
MODEL
GRAPHITE 52M
TOPAZE 32M
MIR 2M
Compound
THC (option CH4)
NO or NOx (option NO2)
CO, CO2, O2
Principle
Heated FID
Heated CLD
NDIR & paramagnetic
Linearity
<1% from 10 to 90% of F.S.
<1% from 10 to 90% of F.S.
<1% from 10 to 90% of F.S.
Lower Detectable Limit
0.05ppm (10ppm range)
0.1 ppm (10ppm range)
<2% of F.S.
Response time (T90 sec)
<1.5 s
<2 s
<2 s
Zero drift
<2% / 7 days
<1% / 7 days
<1% / day
Span drift
<1% / 7 days
<1% / 7 days
<1% / 7 days
Span gases
C3H8 or CH4
NO or NOx
CO, CO2, O2
TOPAZE 32M
MIR 2M
ANALYSERRANGES
RANGES
GRAPHITE 52M
THC
0-10/30,000 ppm
NO or NOx
0-10/10,000 ppm
CO
0-500/10,000 ppm
CO2
0-1/20%
O2
0-5/25%
TECHNICALSPECIFICATION
OPERATING CONDITIONS
GENERAL
• Hang-up checker - used to check for hydrocarbon hangup in the sample lines
• Heated sample line; 10 meters + 3 meters
• Heated sample pump
• Back-flushing filter function
• Heated stainless steel filter
• Remote display & control
• Ambient temperature: 5 to 35oC
• Relative humidity: max 80%
• Power supply: 250v/50/60Hz or 115V/60Hz
• Nominal power consumption: 3.2 kVA
DIMENSIONS
Analyser cabinet
• 19” rack cabinet
• Dimensions: 1,360mm (H) x 600mm (W) x 800mm (D)
UTILITIES
• Compressed air for back purge
• H2/ He (40/60%) for HFID
• N2 (100%) for zero gas
• O2 (100%)
• Air for HFID
4’6” (H) x 2’0” (W) x 2’8” (D)
• Weight: 150kg / 330lbs
Samping trolley
• Dimensions: 1,000mm (H) x 540mm (W) x
3’1” (H) x 1’9” (W) x 1’5” (D)
• Weight: 70kg / 154lbs
11 Ark Royal Way, Lairdside Technology Park, Tranmere, Wirral, CH41 9HT
T: +44(0)151 666 8300 F: +44(0)151 666 8329 E: sales@a1-cbiss.com
W: www.a1-cbiss.com Buy Online: shop.a1-cbiss.com
Cert No. 996
ISO 9001
420mm (D)