The ChemDAQ Steri-Trac gas monitoring system provides toxic gas detection and workplace safety. It features a modular design that allows for custom configurations, and a sensor exchange program that reduces operating costs by replacing sensors every 4 months without requiring on-site calibration. The system monitors ethylene oxide, hydrogen peroxide, ozone, and peracetic acid, and provides trend analysis and early warnings via software.
1. ChemDAQ Steri-Trac
Toxic Gas Detection System
ChemDAQ’s Steri‐Trac gas monitoring system
provides the optimal solution for workplace
safety assurance, providing protection from
toxic gases
Sensor Exchange Program for Reduced Operating Costs
KEYBENEFITS
• DAQ software provides trend
analysis and provides early warning
The unique modular design of the Steri-Trac eliminates the need for
in-house calibration. Using the sensor exchange program (SXP) you can
receive a factory calibrated sensor every 4 months which you swap on site
in a matter of seconds.
of a situation to enable maximum
User friendly Interfaces
protection
Steri-trac’s fixed detectors are designed to be used with the DAQ system
to display gas concentrations, trends and exposures. Using a traffic light
LED alarm system, it’s easy to interpret gas exposure in each area.
• Sensor change out reduces downtime
and costs
Flexibility and Investment Protection
• Modular design for custom
configuration meets facilities specific
needs
• ChemDAQs chemical filter eliminates
ETO
H2O2
Mounted at entrance ways into areas where toxic gases are used or stored,
it duplicates gas readings and alarms from its companion area detector,
providing indication that it’s safe prior to entrance
“
The only fixed detector to
monitor Peracetic acid accurately
at ppm levels
“
GASESANALYSED
O3
Take Personnel Protection to the Next Level
nuisance alarms
PAA
The Steri-Trac toxic gas detector is a fully functioning, micro-processor
controlled unit with tri-colour display and digital communications with
the ability to report gas concentration in parts per million.
2. TECHNICALSPECIFICATION
OUTPUTS
GENERAL
• Fixed detection of Ethylene Oxide, Hydrogen Peroxide &
Oxide
• Sample draw allows for EPA emissions of <1ppm / 24 hour
• Single,. multi point or multi gas installations
• Wide variety of applications including; pharmaceutical &
hospitals, drinks manufacturing and bio-decontamination
• Installation requirements: Wall mounted, 110 VAC, 1amp
• Communications: Digital RS485
• External contact relays: 2 relays open/closed available
• Monitors supported: Up to 8 as standard
CERTIFICATIONS
• Meets OSHA regulations for monitoring toxic gases: CFR
1910.1047, CFR 1910.1000
• Meets Canadian Standards Associations for monitoring
toxic gases: CSA Z314.9-09
PHYSICAL
• Meets OSHA record-keeping requirements 30 years of
• Dimensions: 10” (W) x 6” (H) x 5” (D)
• Display: Tricolour, 4 digit, 1.25”, 5 x 8 Matrix LED
exposure data: CFR 1910.1020
• Meets the Joint Comission Standard EC 02.02.01 and
AAMI ST:41/2005 recommendations
PERFORMANCE
• Alarms: 2 - User adjustable alarm levels, HIGH & LOW
• Output: Linear
• Calibration intervals: 4 months (factory calibrated)
MEASURINGRANGES
Ethylene Oxide
Hydrogen Peroxide
Ozone
Peracetic Acid
Resolution (ppm)
0.1ppm
0.1 ppm
0.002ppm
0-0.1ppm
Sensor range
0-50ppm
0-10 ppm
0-5ppm
0-3ppm
Response time
< 140 sec (T90)
< 150 sec (T90)
< 150 sec (T90)
Temperature /
humidity
-20 to 50oc
15 to 95%
non-condensing
0 to 50oc
15 to 95%
non-condensing
-20 to + 50oc
15 to 95%
non-condensing
11 Ark Royal Way, Lairdside Technology Park, Tranmere, Wirral, CH41 9HT
T: +44(0)151 666 8300 F: +44(0)151 666 8329 E: sales@a1-cbiss.com
W: www.a1-cbiss.com Buy Online: shop.a1-cbiss.com
Cert No. 996