SlideShare a Scribd company logo
1 of 10
Download to read offline
GS510SZ Tech Sheet

 Balboa Instruments
 System PN 54517-01

 System Model # GS5-GS510SZ-RCA-3.0
 Software Version # 43
 EPN # 2765


 Base PCBA - PN 54518-01
 PCB GS500Z - PN 22015 Rev B

 Base Panels
 VL700S – PN 53811
 VL701S (Serial Standard) – PN 53189-01
 VL702S – PN 54652




 Template used: 40599_M.pdf 04/16/2008
 54517-01_97_B.pdf 05/02/2008



http://www.MyPoolSpas.com                Wholesale Pool and Spa Parts
                                                   Page 1               920-925-3094
                                                                             54517-01_97_B
System Revision History
System PN EPN           Date      Requested By                              Changes Made
54517        1780 08.02.2006 Balboa              n/a
54517-01     2765 04.07.2008 Balboa              Software update to v43
54517-01     n/a  05.02.2008 Balboa              Main PCB update to rev B




      http://www.MyPoolSpas.com             Wholesale Pool and Spa Parts
                                                      Page 2                               920-925-3094
                                                                                                54517-01_97_B
Basic System Features and Functions
 Power Requirements




                                                                               Requires PCB Rev B.



 System Outputs
 Setup 1 (As Manufactured)




              (Stereo)


 Optional Devices




  Additional Options                                                                                                 J71
                                                                                     J2A J1A




                                                 J1


                                                 J2




                                                                                                                                                    1
                                                                                                                                              J18
                                                 J10
                                                                                                                 U4

                                                                                                                                  J19


                                                                                                                            J12
                                                 J60                          J7               J8          J44
                                                           1             1             1               1         1
                                                           J22




                                                                                                                                  1
                                                 EXT RLY         AUX F       SEN A             SEN B       VAC        J11

http://www.MyPoolSpas.com    Wholesale Pool and Spa Parts
                                       Page 3                                                                                           920-925-3094
                                                                                                                                             54517-01_97_B
Basic System Features and Functions
Any time you change a DIP Switch, other than A1, you must reset Persistent                                                                                                           Power Up Display Sequence
Memory for your new DIP Switch Settings changes to take effect. If you do                                                                                                            Upon power up, you should see the following on the display:
not reset Persistent Memory, your system may function improperly.                                                                                                                       Three numbers in a row, which are the SSID (the System Software
                                                                                                                                                                                        ID). The third display of these numbers is the Software Version,
To reset Persistent Memory:                                                                                                                                                             which should match the version of your system. For example, if these
     Power down by disconnecting power source from spa.                                                                                                                                 three numbers are                    , that is a VS511SZ at version 38.
     Put a jumper across J43, covering both pins. (See illustration below)                                                                                                              Displayed next is: “ ” (indicating the system is configured for
     Power up by connecting power source to spa.                                                                                                                                        a heater between 3 and 6 kW) or “ ” (indicating the system is
     Wait until “ ” is displayed on your panel.                                                                                                                                         configured for a heater effectively* between 1 and 3 kW).
     Power down again.                                                                                                                                                                  “ ” should appear for all VS models running at 240VAC.
     Remove jumper from J43 (May also move to cover 1 pin only)                                                                                                                         “ ” should appear for all VS models running at 120VAC, as well
                                                                                                                                                                                        as all GS models. (*A heater which is rated at 4 kW at 240VAC will
     Power up again.
                                                                                                                                                                                        function as a 1 kW heater at 120VAC.)
                                                                                                                                                                                        “ ” will appear to signal the start of Priming Mode.
About Persistent Memory and Time of Day Retention:
This system uses memory that doesn’t require a battery to store a variety of
                                                                                                                                                                                     At this point, the power up sequence is complete. Refer to the Reference
settings. What we refer to as Persistent Memory stores the filter settings,
                                                                                                                                                                                     Card for the VS or GS System model of your spa for information about how
the set temperature, and the heat mode.
                                                                                                                                                                                     the spa operates from this point on, including how to adjust the Time of
                                                                                                                                                                                     Day if using a Serial Deluxe style panel.
Persistent Memory is not used for Time of Day. Only models with a
Serial Deluxe panel installed (VS5xxDZ and GS5xxDZ) can display the
time. However, during power loss to the spa, the system will lose the
correct time, and reset to 12:00 PM when power is restored.

                                                           J43


                                                                                                                                                                                                                                                                                  TST                                RST
                                                                                    FUSE 20A 250V                            J47                                                                                                                                                                          J6 J43
                                                                                                                     J46




                                                                       F7                                                                 J29
            K6   J23                                 J50                                                                                                                                                                                   PUMP                  OZONE
                               K1                                                                                                                                                                                                                      J23                 J29
                                                                                                                                                                F1                                                                                                                                                                        F5, F3A 250V                     J20
                                                                                                                                                        J20
                                                                          J17/26




                                                                  J6
  E.GND




                                                                                                                                                                                                                                                   G




                                                                                                                                                                                                                                                                      G




                                                                                                                                                                                                                                                                                           K5
                                                                                                                                                                                              J90




                                                                                                                                                                                                                                                                                                                                                                       G     C
                                                                                                                                                                                                                                                   C




                                                                                                                                                                                                                                                                      C
                                                                                                                                                                      FUSE 3A 250V
                                                                                                                                                         C
                                                                                                                             C




                                                                                                                                              C
                     C




                                                                   C
                                                      C




                                                           S1 TST
                                                                                                                             G




                                                                                                                                                         G
                                                                                                                                              G




                                                                                                                                                                                              J50




                                                                              W7
                                       W4
                     G




                                                                   G
                                                     G




                                                                                                                                                                                                                                                                                                                                               J12
                              W1                                                        K8                                                     K5
  F4 FUSE .3A 250V
                              SWITCHBANK A
                                        T1                                    K9                                  W3
                                                                                                                             W2                                                                          K4      K1
                                                                                                                                                                                                                                                   SWITCHBANK A
                                                                                                             J1 J1A
                                                                                                                                                               J10
                                                                                                                                                                                                                                                                                                                                                                J18
                                                                                                                                                                                                                                                         F2                                                                                                           U4
                                                                                                                                                                                                                                                                                                                                               J13




                                                                                                                    J2A                                                                                       T0.25A 250V
                                                                                                                                                                                                                                                   NEUTRAL
                                                                                                                                                                                                                                                                      WHT AC                                                                                                     J1
                                                                                                                                                                     J18




                                                                                                                                                                                                    W1                                        J58        J57
                                                                                                                                          1       2 3
                         K3                                                                                                                                                                                                                                               K3
                                                                                                                                         U4   J12
                         K2
                                                                                             J2
                                                                                                                                                                                                                                           VS100
                                                                                                                                                                                                                      P/N 22964_B MADE IN U.S.A.




                                                                                                                                                                                            J26                                                                                                 F4
                                                                                                                                                                                                                  Balboa




                                                                             J43
                                                                                                                                                                                                                                 © 2006




                         F2                                                                                                                                                                 LINE
                                                                                                                                                                                                                                                                                      K2




                                                                                                                                                                     J13                                                                                                                                            TST             RST
                                                                                                                                                                                           BLK AC
                                                                                                                                  BALBOA INSTRUMENTS, INC. 2-SPD                                                                                                                                     S1                    J6 J43
                                                                                         J60       J22                        J44 VS500Z                   EXT RLY
                                                                                   J6                       J7        J8                                                                                                                                                                                                                       J7          J8
                                             E.GND




                                                                                                                                  P/N 22972 REV D
                                                                                                                                                                                                                                                                                 J9




                                                                            S1 TST       EXT.
                                                                                           T      AUX. F                      VAC MADE IN U.S.A
                                                                                                                              V
                                                           SWITCHBANK A                  RLY
                                                                                          L                SEN. A   SEN. B         COPYRIGHT 2005                                                                                                            HEATER
                                                                                                                                                                                                                                                               A
                                                                                                                                                                                                                                                                                                            SWITCHBANK A                      SEN. A     SEN. B



  J43 on VS5xxZ and VS300 Series Main Board Shown.                                                                                                                                          J43 on VS100/GS100 Series Main Board Shown.
  J43 on GS5xxZ Series is located in approximately the same position.




             http://www.MyPoolSpas.com                                                                                                                  Wholesale Pool and Spa Parts
                                                                                                                                                                  Page 4                                                                                                                                                             920-925-3094
                                                                                                                                                                                                                                                                                                                                          54517-01_97_B
Wiring Configuration and DIP Settings
          Setup 1 (As Manufactured)                                                                                                                                                                                   HIPot Testing Note:
                                                                                                                                                                                                                      Disconnect slip terminal with green
                                                                                                                                                                                                                      wires from J90 prior to performing
                                                                                                                                                                                                                      HiPot test. Failure to disconnect may
                                                                                      (Stereo)                                             VL702S Main Panel                                                          cause a false failure of the test.
                                                                                                                                                                                                                      Reconnect terminal to J90 after
                                                                                                                                                                                                                      successful completion of HiPot test.
                                                                   AV                                                                                                                                                                          F7                                                              F1   J13
                                                   J50                                      J29                    J23                                         K6            K1                                                              F10A 250V
                                                                                            OZONE                 PUMP 1                       K9
                                                                                                                                                                                                                                                                            F3A 250V
            J52             J F6, T30A 480V
                            J51
                                                          Audio Visual
                                                           G N
                                                                                                                                                                                                                 J46




                                                                                                                                                                                        Blower
                                                                                                                 2-Spd P1
                                                                                                                 1-Spd P1
                                                                                            Ozone
                                                    J47




                                                                        CIRC. PUMP
                                                                                                                                                                                                                      K8
                                                                                                                                                                                                                                                            K5          J20
                                                          Circ Pump




                                                                                                                                                                                           N
                                    J25
                                      5                    G N                                                                                                                                                                                        C9                                     Spa
                                                                                                N




                                                                                                                     N
                                                                                                                                                                                                                                                                                             G   N
                                    J32
                                      2                                                                                                                                                                                                                                                      Light




                                                                                                                                                                                           G
                                                                                                G




                                                                                                                    G
                                                                                                                                                                                                                                                                                  F3
                                             TB1                                                                                                                                                                 10VAC




                                                                                                                                                                                                                                                                                                   10VAC
                                                                                                                                                                                        J17/26                   J72
                                      1                         F4, T0.2A 250V                                                                                                          OPT. BLWR/PUMP 2                                                                               J71
                                                                                                                                                    T1
                                                                                                         J58




                                                                                                                                                                                                                                                      J2A J1A
                                      2                                                                                                                                                                          J1
                                                                                                W2
                                                                   J28
                                                                     8
                                                                                                                                                                                                                  J2
                                      3
                                                                          J26
                                                                            6




                                                                                                                                     K3




                                                                                                                                                                                                                                                                                                                                1
                                                                                                                                                                                                                                                                                                                          J18
                                      4                                                                                                                                                                    J43   J10
                                                                                                                                     K4




                                                                                                                                                                                                                                                                                  U4
                               J57
                                                                                                                                                                F2

                    Balboa
                                                                                                                                                                                                                                                                                                       J19

                                                   HTR2     J101                     HTR1       00                                  K2                                  S1
                                             W1                                                                                                J90                                                                                                                                               J12
                   BALBOA INSTRUMENTS, INC                                                                                                                                                                        J60                          J7               J8          J44
                                                                                                                                                                                                           J6
                                                                                                                                                                                                                                                                                                             GS5xxSZ mode
                                                                                                                                                                E.GND




                   GS500Z                                                                                                                                                                                                  1             1              1               1         1
                   COPYRIGHT 2007




                                                                                                                                                                                                                           J22
                   MADE IN U.S.A.                                                                                                                                                                          TST                                                                                         1
                   P/N 22015_B                                                                                                                                                    SWITCHBANK A                   EXT RLY         AUX F        SEN A             SEN B       VAC        J11



                  Heater rated @ 240V                                                                                                                                                                                                                                             3.0kW
                  J11 must be Jumpered
                                                          3.0 kW

                                                                                                                                          J6
                                                                                                K2
                                                                                                                                                1-Spd P2
                                                                                                                                                R  B W G




                                                                                                           J2
                                                                                                            J4                                           W12




WARNING: Main Power to system should be turned OFF BEFORE adjusting DIP switches.
WARNING: Persistent Memory (J43) must be RESET to allow new DIP switch settings to take effect. (See Persistent Memory page)

                                                                                                                                          GS500/501/510SZ
  SSID #                                                                                                                                     Software
                                                                                                                                                                                                                   Wiring Color Key
                                                                                                                 J11                       J12           3
                                                                                                                                                                                                                                                                        Neutral (Common) AC Connections
    100                                                                                           3.0kW                                                                                                                                                                 Special AC Connections
    65                                                                                            Heater                                                 2                                                                                                              Line AC Connections
    43                                                                                                                                                                                                                                                                  10 Volt Connections
                    A1, Test Mode OFF                                   A6, 50 Hz                                                                        1
                                                                                                                                                                                                                                                                        Relay Control Wires
                    A2, See Table 1                                     A7, J17/26 Disabled
                                                                                   Enabled
                    A3, Exp Pump Disabled
                                 Enabled                                                                                                                                J43
                                                                        A8, Degrees C                                                                                   Memory                                     Board Connector Key
                                                                        A9, Non-Circ Mode                                                                               Reset
                    A5, 2-speed P1                                      A10, See Table 1
                                                                                                                                                                                                                   1                         Typically Line voltage
                                                                                                                                                                                                                   2                         Typically Line voltage for 2-speed pumps
   Panel Button Assignments                                                                         Panel Button Positions
                                                                                                                                                                                                                   3                         Neutral (Common)
   1=Mode               5=Pump 1                                                                                                    2                                        4      7
                                                            7                   1                    2                                                                                                             4
   2=Temp Up            6=Unused
                        6=Exp Pump                                                                                                                                                                                                           Ground
                                                                                                                            1       3                                        5      6
   3=Temp Down          7=Unused
                        7=J17/26                            5       6           4                    3
                                                                                                                                                                                                                                             Note flat sides in connector
   4=Light
                                                                                                5                               2
                                                                                            6                                       1
       http://www.MyPoolSpas.com                                                                     Wholesale Pool and Spa Parts
                                                                                                               Page 5                                                                                                                                                              920-925-3094
                                                                                                                                                                                                                                                                                        54517-01_97_B
DIP Switches and Jumpers Definitions
   SSID 100 65 43                                           Base Model GS500SZ-GS501SZ-GS510SZ
DIP Switch Key
     A1 Test Mode (normally OFF)
A2+A10 Control amp draw requirements (See Table 1)                                                                Table 1         # of Hi-Speed
     A3 “ON” position: Expander Board Enabled for 1-speed Pump only.*                                                             Pumps/Blower
         “OFF” position: Expander Board Disabled.                                                                              Before Heat Disabled
     A4 Aux Freeze (must be OFF)                                                                                  A2        A10
 A5+A9 Pump 1 speeds and Circ Modes:                                                                              OFF       OFF           0
              A5      A9        Circ Mode                                             Pump 1 Speed                ON        OFF           1
              OFF     OFF       Non-circ                                              2-speed                     OFF       ON            2
              ON      OFF       Circ "acts like Pump 1 low" (filters/polls/ect)       1-speed                     ON        ON            3
              OFF     ON        24 hours with 3°F shut-off                            1-speed
              ON      ON        24 hours with 3°F shut-off                            2-speed
     A6 “ON” position: 50Hz operation
           “OFF” position: 60Hz operation
     A7 “ON” position: J17/26 Enabled for Blower or 1-speed Pump.*
           “OFF” position: J17/26 Disabled
     A8 “ON” position: temperature is displayed in degrees Celsius
           “OFF” position: temperature is displayed in degrees Fahrenheit
* Panel with button layout         is not compatible when both A3 and A7 are ON.
Jumper Key
J11       If using 3kW or higher wattage heater, jumper can be set in either position, but may perform better on Pins 1 and 2.
          If using 2.5kW or lower wattage heater, jumper must be set on 1 Pin only.
J12       Factory set. DO NOT MOVE.
          Jumper must be on Pins 1 and 2 for GS51xZ/GS52xZ/GS5xxSZ/GS5xxDZ software.
          Jumper must be on Pins 2 and 3 for GS50xZ software.
J43       When jumper is placed on 2 pins during power-up, system will reset persistent memory.
          Leave on 1 pin only to enable persistent memory feature.
 WARNING:
  Setting DIP switches incorrectly may cause abnormal system behavior and/or damage to system components.
  Refer to Switchbank illustration on Wiring Configuration page for correct settings for this system.
  Contact Balboa if you require additional configuration pages added to this tech sheet.


              Panel Button Positions                                                                       Aux Panel Information

      7       1                 2                      2                          4     7            Supports 2-button aux panel

      5   6   4                 3              1       3                          5     6
                                                                                                 VX20         5         6
                            5                      2
                        6                              1
                            4                      3
                                                                                                     Supports 4-button aux panel
              Panel Button Assignments                                                           VX40S        5 6            7 4
                                     A7: OFF           A7: ON
  1=Mode
  2=Temp Up                         6=Unused 6=J17/26
                     A3: OFF 7=Unused 7=Unused
  3=Temp Down
  4=Light                           6=Exp Pump 6=Exp Pump
                     A3:ON 7=Unused 7=J17/26
  5=Pump 1

 http://www.MyPoolSpas.com                                 Wholesale Pool and Spa Parts
                                                                     Page 6                                                       920-925-3094
                                                                                                                                       54517-01_97_B
Electrical Service Configuration Options
                        Systems with PCB Rev B Only                  J50
                                                                                        AV
                                                                                                                 J29
                                                                                                                 OZONE
                                                                                                                                  J23
                                                                                                                                 PUMP 1         K9
                                                                                                                                                            K6            K1
                                                                                                                                                                                                                                                 F7
                                                                                                                                                                                                                                               F10A 250V
                                                                                                                                                                                                                                                                                                                   F1   J13


                           J52            J51 F6, T30A 480V
                                          J                                                                                                                                                                                                                                    F3A 250V
                                                                             G     N
                                                                                                                                                                                                              J46

                                                                                                                                                          Single Service, TN and TT Electrical Systems
                                                                       J47
                                                                                             CIRC. PUMP
                                                                                                                                                                                                                   K8
                                                                                                                                                                                                                                                              K5          J20




                                                                                                                                                                                         N
                                                   J25
                                                     5                       G     N                                                                                                                                                                    C9




                                                                                                                   N




                                                                                                                                   N
                                                   J32
                                                     2                                                                                                    (1 x 16 Amp or 1 x 32 Amp)                                                                                                           G             N




                                                                                                                                                                                        G
                                                                                                                   G




                                                                                                                                  G
                                                                                                                                                                                                                                                                                    F3
                                                               TB1                                                                                                        10VAC
                                                                                                                                                          3 Wires (1 Line + 1 Neutral + 1J71Protective Earth)




                                                                                                                                                                                                                                                                                                     10VAC
                                                                                                                                                                   J17/26 J72
                                                     1                                 F4, T0.2A 250V                                                                                OPT. BLWR/PUMP 2
                                                                                                                                                     T1
                                                                                                                         J58
                                                                                                                                                          Protective Earth wire (Green/Yellow) must be connected
                                                                                                                                                          to system ground terminal as marked.




                                                                                                                                                                                                                                                        J2A J1A
AS MANUFACTURED




                                                     2                                                                                                                                                        J1
                                                                                                                    W2
                                                                                        J28
                                                                                          8                                                               This option is configured and shipped as the default.
                                                                                                                                                                           J2
                  L1                                 3
                                                                                               J26
                                                                                                 6




                                                                                                                                           K3
                                                                                                                                                          All equipment (pumps, blower, and heater) runs on
                  N1                                                                                                                                      service line L1.                                                                                                                                                    J18
                                                                                                                                                                                                                                                                                                                                    1

                                                     4                                                                                                                                                  J43   J10




                                                                                                                                           K4
                                                                                                                                                                                                                                                                                    U4
                                              J57
                                                                                                                                                             F2

                                  Balboa
                                                                                                                                                                                                                                                                                                             J19



                                 BALBOA INSTRUMENTS, INC.
                                                               W1
                                                                     HTR2        J101                     HTR1     00                     K2
                                                                                                                                                J90       Systems using only 1 DIP switch (A10) for heat disable:
                                                                                                                                                                     S1

                                                                                                                                                                                                        J6
                                                                                                                                                                                                               J60                               J7                J8         J44
                                                                                                                                                                                                                                                                                                   J12




                                                                                                                                                             E.GND
                                                                                                                                                                                                                                                          1               1
                                 GS500Z
                                 COPYRIGHT 2007           Pb
                                                          Pb
                                                                                                                                                            For 1 x 16 Amp Service:                                      1                 1                                         1




                                                                                                                                                                                                                             J22
                                 MADE IN U.S.A.                                                                                                                                                         TST                                                                                              1
                                 P/N 22015_B                                                                                                                                   SWITCHBANK A                    EXT RLY             AUX F        SEN A             SEN B       VAC        J11

                                                                                                                                                              DIP Switch A10 must be ON.
                                                                                                                                                            For 1 x 32 Amp Service:
                                                                                                                                                              Set DIP Switch A10 such that total system amperage
                                                                                                                                                              draw never exceeds rated service input.
                                                                                                                                                          Systems using multiple DIP switches for heat disable:
                                                                                                                                                            Refer to system Hot Sheet DIP Switch Definition page
                                                                                                                                                            and set the switches shown in Table 1 such that total
                                                                                                                                                            system amperage draw never exceeds rated service input.

                                                                                        AV                                                                                                                                                       F7                                                                F1   J13
                                                                     J50                                         J29             J23                        K6            K1                                                                   F10A 250V
                                                                                                                 OZONE           PUMP 1         K9
                           J52            J51 F6, T30A 480V
                                          J                                                                                                                                                                                                                                   F3A 250V
                                                                             G     N
                                                                                                                                                                                                              J46

                                                                                                                                                          Dual Service, TN and TT Electrical Systems
                                                                      J47




                                                                                             CIRC. PUMP
                                                                                                                                                                                                                   K8
                                                                                                                                                                                                                                                              K5          J20
                                                                                                                                                                                        N




                                                   J25
                                                     5                       G     N                                                                                                                                                                    C9
                                                                                                                                                          (2 x 16 Amp)
                                                                                                                   N




                                                                                                                                  N




                                                                                                                                                                                                                                                                                               G             N
                                                   J32
                                                     2
                                                                                                                                                                                        G
                                                                                                                   G




                                                                                                                                  G




                                                                                                                                                                                                                                                                                    F3
                                                               TB1

                                                     1                              F4, T0.2A 250V
                                                                                                                                                          5 Wires (2 Lines10VAC 2 Neutrals + 1 Protective Earth)
                                                                                                                                                                   J17/26   +
                                                                                                                                                                          J72
                                                                                                                                                                                     OPT. BLWR/PUMP 2
                                                                                                                                                                                           J71
                                                                                                                                                                                                                                                                                                     10VAC

                  L2                                                                                                                                 T1
                                                                                                                                                          Protective Earth wire (Green/Yellow) must be connected
                                                                                                                         J58
                                                                                                                                                          to system ground terminal as marked.
                                                                                                                                                                                                                                                        J2A J1A




                  N2                                 2                                                                                                                                                        J1
                                                                                                                    W2
                                                                                        J28
                                                                                          8                                                               The heater runs on service line L1, while all other
                                                                                                                                                                           J2
OPTIONAL




                  L1                                 3
                                                                                                                                                          equipment, such as pumps and blowers, run on
                                                                                               J26
                                                                                                 6




                                                                                                                                           K3




                                                                                                                                                          service line L2.
                  N1                                                                                                                                                                                                                                                                                                          J18
                                                                                                                                                                                                                                                                                                                                    1

                                                     4                                                                                                                                                  J43   J10
                                                                                                                                           K4




                                              J57                                                                                                         Completely remove the white wire from J26 and J32.
                                                                                                                                                             F2
                                                                                                                                                                                                                                                                                    U4



                                 Balboa
                                                                                                                                                                                                                                                                                                         J19



                                 BALBOA INSTRUMENTS, INC.
                                                               W1
                                                                     HTR2        J101                     HTR1     00                     K2
                                                                                                                                                J90        Note: J32 and J25 are electrically identical. The white
                                                                                                                                                                     S1

                                                                                                                                                                                                        J6
                                                                                                                                                                                                               J60                               J7               J8          J44
                                                                                                                                                                                                                                                                                                   J12
                                                                                                                                                             E.GND




                                                                                                                                                                                                                                                          1               1
                                 GS500Z
                                 COPYRIGHT 2007           Pb
                                                          Pb
                                                                                                                                                           wire may be attached to either terminal before removal.       1                 1                                        1
                                                                                                                                                                                                                         J22




                                 MADE IN U.S.A.                                                                                                                                                         TST                                                                                              1
                                 P/N 22015_B                                                                                                                                   SWITCHBANK A                   EXT RLY              AUX F        SEN A             SEN B       VAC        J11




                                                                                                                                                          Systems using only 1 DIP switch (A10) for heat disable:
                                                                                                                                                            DIP Switch A10 must be OFF.
                                                                                                                                                          Systems using multiple DIP switches for heat disable:
                                                                                                                                                            Refer to system Hot Sheet DIP Switch Definition page
                                                                                                                                                            and set both switches shown in Table 1 to ON positions.




                       http://www.MyPoolSpas.com                                                                               Wholesale Pool and Spa Parts
                                                                                                                                         Page 7                                                                                                                                                                    920-925-3094
                                                                                                                                                                                                                                                                                                                        54517-01_97_B
54517 01 gs5_gs510_sz_rca-30
54517 01 gs5_gs510_sz_rca-30
54517 01 gs5_gs510_sz_rca-30

More Related Content

What's hot

What's hot (20)

54521 02 gs5_gs511_sz_rca-30
54521 02 gs5_gs511_sz_rca-3054521 02 gs5_gs511_sz_rca-30
54521 02 gs5_gs511_sz_rca-30
 
55421 01 gs5_gs520_dz_rca-30
55421 01 gs5_gs520_dz_rca-3055421 01 gs5_gs520_dz_rca-30
55421 01 gs5_gs520_dz_rca-30
 
55896 gs5 gs513_z_rca_30
55896 gs5 gs513_z_rca_3055896 gs5 gs513_z_rca_30
55896 gs5 gs513_z_rca_30
 
55250 01 gs5_gs501_dz_rca-30
55250 01 gs5_gs501_dz_rca-3055250 01 gs5_gs501_dz_rca-30
55250 01 gs5_gs501_dz_rca-30
 
54519 02 gs5_gs511_z_rca-30
54519 02 gs5_gs511_z_rca-3054519 02 gs5_gs511_z_rca-30
54519 02 gs5_gs511_z_rca-30
 
54751 01 gs5_gs520_dz_rca-30
54751 01 gs5_gs520_dz_rca-3054751 01 gs5_gs520_dz_rca-30
54751 01 gs5_gs520_dz_rca-30
 
54763 01 gs5_gs523_dz_rca-30
54763 01 gs5_gs523_dz_rca-3054763 01 gs5_gs523_dz_rca-30
54763 01 gs5_gs523_dz_rca-30
 
55509 gs5 gs501_z_rca_20
55509 gs5 gs501_z_rca_2055509 gs5 gs501_z_rca_20
55509 gs5 gs501_z_rca_20
 
54511 01 gs5_gs501_z_rca-30
54511 01 gs5_gs501_z_rca-3054511 01 gs5_gs501_z_rca-30
54511 01 gs5_gs501_z_rca-30
 
54752 01 gs5_gs520_sz_rca-30
54752 01 gs5_gs520_sz_rca-3054752 01 gs5_gs520_sz_rca-30
54752 01 gs5_gs520_sz_rca-30
 
55471 gs5 gs501_z_rca_30
55471 gs5 gs501_z_rca_3055471 gs5 gs501_z_rca_30
55471 gs5 gs501_z_rca_30
 
55613 gs5 gs501_z_rca_15
55613 gs5 gs501_z_rca_1555613 gs5 gs501_z_rca_15
55613 gs5 gs501_z_rca_15
 
54559 01 vsp_vs510_sz_dcaj
54559 01 vsp_vs510_sz_dcaj54559 01 vsp_vs510_sz_dcaj
54559 01 vsp_vs510_sz_dcaj
 
54371 02 vsp_vs510_sz_dcah
54371 02 vsp_vs510_sz_dcah54371 02 vsp_vs510_sz_dcah
54371 02 vsp_vs510_sz_dcah
 
55415 01 gs5_gs510_dz_rca-30
55415 01 gs5_gs510_dz_rca-3055415 01 gs5_gs510_dz_rca-30
55415 01 gs5_gs510_dz_rca-30
 
55991 vsp vs501_z_dcaj
55991 vsp vs501_z_dcaj55991 vsp vs501_z_dcaj
55991 vsp vs501_z_dcaj
 
55423 01 gs5_gs520_sz_rca-30
55423 01 gs5_gs520_sz_rca-3055423 01 gs5_gs520_sz_rca-30
55423 01 gs5_gs520_sz_rca-30
 
54848 gs5 gs525_z_rca_30k
54848 gs5 gs525_z_rca_30k54848 gs5 gs525_z_rca_30k
54848 gs5 gs525_z_rca_30k
 
55053 03 vsp_vs511_sz_dcaj
55053 03 vsp_vs511_sz_dcaj55053 03 vsp_vs511_sz_dcaj
55053 03 vsp_vs511_sz_dcaj
 
56016 01 vsp_vs520_dz_ycah
56016 01 vsp_vs520_dz_ycah56016 01 vsp_vs520_dz_ycah
56016 01 vsp_vs520_dz_ycah
 

Similar to 54517 01 gs5_gs510_sz_rca-30 (14)

55399 gs5 gs501_z_rca_30
55399 gs5 gs501_z_rca_3055399 gs5 gs501_z_rca_30
55399 gs5 gs501_z_rca_30
 
54509 01 gs5_gs500_z_rca-30
54509 01 gs5_gs500_z_rca-3054509 01 gs5_gs500_z_rca-30
54509 01 gs5_gs500_z_rca-30
 
54523 01 gs5_gs500_z_rca-20
54523 01 gs5_gs500_z_rca-2054523 01 gs5_gs500_z_rca-20
54523 01 gs5_gs500_z_rca-20
 
54382 04 vsp_vs511_z_dcah
54382 04 vsp_vs511_z_dcah54382 04 vsp_vs511_z_dcah
54382 04 vsp_vs511_z_dcah
 
54371 02 vsp_vs510_sz_dcah
54371 02 vsp_vs510_sz_dcah54371 02 vsp_vs510_sz_dcah
54371 02 vsp_vs510_sz_dcah
 
54637 01 vsp_vs504_sz_dcah
54637 01 vsp_vs504_sz_dcah54637 01 vsp_vs504_sz_dcah
54637 01 vsp_vs504_sz_dcah
 
54639 01 vsp_vs514_sz_ycah
54639 01 vsp_vs514_sz_ycah54639 01 vsp_vs514_sz_ycah
54639 01 vsp_vs514_sz_ycah
 
55474 01 gs5_gs515_z_rca-30k
55474 01 gs5_gs515_z_rca-30k55474 01 gs5_gs515_z_rca-30k
55474 01 gs5_gs515_z_rca-30k
 
55370 01 vsp_vs504_sz_dcaj
55370 01 vsp_vs504_sz_dcaj55370 01 vsp_vs504_sz_dcaj
55370 01 vsp_vs504_sz_dcaj
 
54635 01 vsp_vs503_sz_dcah
54635 01 vsp_vs503_sz_dcah54635 01 vsp_vs503_sz_dcah
54635 01 vsp_vs503_sz_dcah
 
54337 0420 vsp_vs500z_fcah
54337 0420 vsp_vs500z_fcah54337 0420 vsp_vs500z_fcah
54337 0420 vsp_vs500z_fcah
 
54337 0420 vsp_vs500z_fcah
54337 0420 vsp_vs500z_fcah54337 0420 vsp_vs500z_fcah
54337 0420 vsp_vs500z_fcah
 
56007 01 vsp_vs520_sz_dcah
56007 01 vsp_vs520_sz_dcah56007 01 vsp_vs520_sz_dcah
56007 01 vsp_vs520_sz_dcah
 
56007 01 vsp_vs520_sz_dcah
56007 01 vsp_vs520_sz_dcah56007 01 vsp_vs520_sz_dcah
56007 01 vsp_vs520_sz_dcah
 

More from Accurate Pool & Spa Services, llc

More from Accurate Pool & Spa Services, llc (20)

Ultimate spaside instruction sheet
Ultimate spaside instruction sheetUltimate spaside instruction sheet
Ultimate spaside instruction sheet
 
Standard spaside instruction sheet
Standard spaside instruction sheetStandard spaside instruction sheet
Standard spaside instruction sheet
 
Ps 9704 manual-rev1_2
Ps 9704 manual-rev1_2Ps 9704 manual-rev1_2
Ps 9704 manual-rev1_2
 
Ps 7100 manual-rev1_2
Ps 7100 manual-rev1_2Ps 7100 manual-rev1_2
Ps 7100 manual-rev1_2
 
Ps 6500 manual-rev1_2
Ps 6500 manual-rev1_2Ps 6500 manual-rev1_2
Ps 6500 manual-rev1_2
 
Hq label wd highlight
Hq label wd highlightHq label wd highlight
Hq label wd highlight
 
Eco 3 spaside instruction sheet
Eco 3 spaside instruction sheetEco 3 spaside instruction sheet
Eco 3 spaside instruction sheet
 
Eco 2 spaside instruction sheet
Eco 2 spaside instruction sheetEco 2 spaside instruction sheet
Eco 2 spaside instruction sheet
 
Eco 1 spaside instruction sheet
Eco 1 spaside instruction sheetEco 1 spaside instruction sheet
Eco 1 spaside instruction sheet
 
Eco 2 pcb revisions
Eco 2 pcb revisionsEco 2 pcb revisions
Eco 2 pcb revisions
 
Eco 1 programming
Eco 1 programmingEco 1 programming
Eco 1 programming
 
Deluxe spaside instruction sheet
Deluxe spaside instruction sheetDeluxe spaside instruction sheet
Deluxe spaside instruction sheet
 
Cs9700 software upgrade notice 3 07
Cs9700 software upgrade notice 3 07Cs9700 software upgrade notice 3 07
Cs9700 software upgrade notice 3 07
 
Cs9700 llp settings 3 07
Cs9700 llp settings 3 07Cs9700 llp settings 3 07
Cs9700 llp settings 3 07
 
Control cord colors
Control cord colorsControl cord colors
Control cord colors
 
850077 a outdoor operation
850077 a outdoor operation850077 a outdoor operation
850077 a outdoor operation
 
9400 9600 programming
9400 9600 programming9400 9600 programming
9400 9600 programming
 
9300 programming
9300 programming9300 programming
9300 programming
 
85 0138 infrared remote-web
85 0138 infrared remote-web85 0138 infrared remote-web
85 0138 infrared remote-web
 
85 0137 rev 1-palm pilot programming_web
85 0137 rev 1-palm pilot programming_web85 0137 rev 1-palm pilot programming_web
85 0137 rev 1-palm pilot programming_web
 

54517 01 gs5_gs510_sz_rca-30

  • 1. GS510SZ Tech Sheet Balboa Instruments System PN 54517-01 System Model # GS5-GS510SZ-RCA-3.0 Software Version # 43 EPN # 2765 Base PCBA - PN 54518-01 PCB GS500Z - PN 22015 Rev B Base Panels VL700S – PN 53811 VL701S (Serial Standard) – PN 53189-01 VL702S – PN 54652 Template used: 40599_M.pdf 04/16/2008 54517-01_97_B.pdf 05/02/2008 http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 1 920-925-3094 54517-01_97_B
  • 2. System Revision History System PN EPN Date Requested By Changes Made 54517 1780 08.02.2006 Balboa n/a 54517-01 2765 04.07.2008 Balboa Software update to v43 54517-01 n/a 05.02.2008 Balboa Main PCB update to rev B http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 2 920-925-3094 54517-01_97_B
  • 3. Basic System Features and Functions Power Requirements Requires PCB Rev B. System Outputs Setup 1 (As Manufactured) (Stereo) Optional Devices Additional Options J71 J2A J1A J1 J2 1 J18 J10 U4 J19 J12 J60 J7 J8 J44 1 1 1 1 1 J22 1 EXT RLY AUX F SEN A SEN B VAC J11 http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 3 920-925-3094 54517-01_97_B
  • 4. Basic System Features and Functions Any time you change a DIP Switch, other than A1, you must reset Persistent Power Up Display Sequence Memory for your new DIP Switch Settings changes to take effect. If you do Upon power up, you should see the following on the display: not reset Persistent Memory, your system may function improperly. Three numbers in a row, which are the SSID (the System Software ID). The third display of these numbers is the Software Version, To reset Persistent Memory: which should match the version of your system. For example, if these Power down by disconnecting power source from spa. three numbers are , that is a VS511SZ at version 38. Put a jumper across J43, covering both pins. (See illustration below) Displayed next is: “ ” (indicating the system is configured for Power up by connecting power source to spa. a heater between 3 and 6 kW) or “ ” (indicating the system is Wait until “ ” is displayed on your panel. configured for a heater effectively* between 1 and 3 kW). Power down again. “ ” should appear for all VS models running at 240VAC. Remove jumper from J43 (May also move to cover 1 pin only) “ ” should appear for all VS models running at 120VAC, as well as all GS models. (*A heater which is rated at 4 kW at 240VAC will Power up again. function as a 1 kW heater at 120VAC.) “ ” will appear to signal the start of Priming Mode. About Persistent Memory and Time of Day Retention: This system uses memory that doesn’t require a battery to store a variety of At this point, the power up sequence is complete. Refer to the Reference settings. What we refer to as Persistent Memory stores the filter settings, Card for the VS or GS System model of your spa for information about how the set temperature, and the heat mode. the spa operates from this point on, including how to adjust the Time of Day if using a Serial Deluxe style panel. Persistent Memory is not used for Time of Day. Only models with a Serial Deluxe panel installed (VS5xxDZ and GS5xxDZ) can display the time. However, during power loss to the spa, the system will lose the correct time, and reset to 12:00 PM when power is restored. J43 TST RST FUSE 20A 250V J47 J6 J43 J46 F7 J29 K6 J23 J50 PUMP OZONE K1 J23 J29 F1 F5, F3A 250V J20 J20 J17/26 J6 E.GND G G K5 J90 G C C C FUSE 3A 250V C C C C C C S1 TST G G G J50 W7 W4 G G G J12 W1 K8 K5 F4 FUSE .3A 250V SWITCHBANK A T1 K9 W3 W2 K4 K1 SWITCHBANK A J1 J1A J10 J18 F2 U4 J13 J2A T0.25A 250V NEUTRAL WHT AC J1 J18 W1 J58 J57 1 2 3 K3 K3 U4 J12 K2 J2 VS100 P/N 22964_B MADE IN U.S.A. J26 F4 Balboa J43 © 2006 F2 LINE K2 J13 TST RST BLK AC BALBOA INSTRUMENTS, INC. 2-SPD S1 J6 J43 J60 J22 J44 VS500Z EXT RLY J6 J7 J8 J7 J8 E.GND P/N 22972 REV D J9 S1 TST EXT. T AUX. F VAC MADE IN U.S.A V SWITCHBANK A RLY L SEN. A SEN. B COPYRIGHT 2005 HEATER A SWITCHBANK A SEN. A SEN. B J43 on VS5xxZ and VS300 Series Main Board Shown. J43 on VS100/GS100 Series Main Board Shown. J43 on GS5xxZ Series is located in approximately the same position. http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 4 920-925-3094 54517-01_97_B
  • 5. Wiring Configuration and DIP Settings Setup 1 (As Manufactured) HIPot Testing Note: Disconnect slip terminal with green wires from J90 prior to performing HiPot test. Failure to disconnect may (Stereo) VL702S Main Panel cause a false failure of the test. Reconnect terminal to J90 after successful completion of HiPot test. AV F7 F1 J13 J50 J29 J23 K6 K1 F10A 250V OZONE PUMP 1 K9 F3A 250V J52 J F6, T30A 480V J51 Audio Visual G N J46 Blower 2-Spd P1 1-Spd P1 Ozone J47 CIRC. PUMP K8 K5 J20 Circ Pump N J25 5 G N C9 Spa N N G N J32 2 Light G G G F3 TB1 10VAC 10VAC J17/26 J72 1 F4, T0.2A 250V OPT. BLWR/PUMP 2 J71 T1 J58 J2A J1A 2 J1 W2 J28 8 J2 3 J26 6 K3 1 J18 4 J43 J10 K4 U4 J57 F2 Balboa J19 HTR2 J101 HTR1 00 K2 S1 W1 J90 J12 BALBOA INSTRUMENTS, INC J60 J7 J8 J44 J6 GS5xxSZ mode E.GND GS500Z 1 1 1 1 1 COPYRIGHT 2007 J22 MADE IN U.S.A. TST 1 P/N 22015_B SWITCHBANK A EXT RLY AUX F SEN A SEN B VAC J11 Heater rated @ 240V 3.0kW J11 must be Jumpered 3.0 kW J6 K2 1-Spd P2 R B W G J2 J4 W12 WARNING: Main Power to system should be turned OFF BEFORE adjusting DIP switches. WARNING: Persistent Memory (J43) must be RESET to allow new DIP switch settings to take effect. (See Persistent Memory page) GS500/501/510SZ SSID # Software Wiring Color Key J11 J12 3 Neutral (Common) AC Connections 100 3.0kW Special AC Connections 65 Heater 2 Line AC Connections 43 10 Volt Connections A1, Test Mode OFF A6, 50 Hz 1 Relay Control Wires A2, See Table 1 A7, J17/26 Disabled Enabled A3, Exp Pump Disabled Enabled J43 A8, Degrees C Memory Board Connector Key A9, Non-Circ Mode Reset A5, 2-speed P1 A10, See Table 1 1 Typically Line voltage 2 Typically Line voltage for 2-speed pumps Panel Button Assignments Panel Button Positions 3 Neutral (Common) 1=Mode 5=Pump 1 2 4 7 7 1 2 4 2=Temp Up 6=Unused 6=Exp Pump Ground 1 3 5 6 3=Temp Down 7=Unused 7=J17/26 5 6 4 3 Note flat sides in connector 4=Light 5 2 6 1 http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 5 920-925-3094 54517-01_97_B
  • 6. DIP Switches and Jumpers Definitions SSID 100 65 43 Base Model GS500SZ-GS501SZ-GS510SZ DIP Switch Key A1 Test Mode (normally OFF) A2+A10 Control amp draw requirements (See Table 1) Table 1 # of Hi-Speed A3 “ON” position: Expander Board Enabled for 1-speed Pump only.* Pumps/Blower “OFF” position: Expander Board Disabled. Before Heat Disabled A4 Aux Freeze (must be OFF) A2 A10 A5+A9 Pump 1 speeds and Circ Modes: OFF OFF 0 A5 A9 Circ Mode Pump 1 Speed ON OFF 1 OFF OFF Non-circ 2-speed OFF ON 2 ON OFF Circ "acts like Pump 1 low" (filters/polls/ect) 1-speed ON ON 3 OFF ON 24 hours with 3°F shut-off 1-speed ON ON 24 hours with 3°F shut-off 2-speed A6 “ON” position: 50Hz operation “OFF” position: 60Hz operation A7 “ON” position: J17/26 Enabled for Blower or 1-speed Pump.* “OFF” position: J17/26 Disabled A8 “ON” position: temperature is displayed in degrees Celsius “OFF” position: temperature is displayed in degrees Fahrenheit * Panel with button layout is not compatible when both A3 and A7 are ON. Jumper Key J11 If using 3kW or higher wattage heater, jumper can be set in either position, but may perform better on Pins 1 and 2. If using 2.5kW or lower wattage heater, jumper must be set on 1 Pin only. J12 Factory set. DO NOT MOVE. Jumper must be on Pins 1 and 2 for GS51xZ/GS52xZ/GS5xxSZ/GS5xxDZ software. Jumper must be on Pins 2 and 3 for GS50xZ software. J43 When jumper is placed on 2 pins during power-up, system will reset persistent memory. Leave on 1 pin only to enable persistent memory feature. WARNING: Setting DIP switches incorrectly may cause abnormal system behavior and/or damage to system components. Refer to Switchbank illustration on Wiring Configuration page for correct settings for this system. Contact Balboa if you require additional configuration pages added to this tech sheet. Panel Button Positions Aux Panel Information 7 1 2 2 4 7 Supports 2-button aux panel 5 6 4 3 1 3 5 6 VX20 5 6 5 2 6 1 4 3 Supports 4-button aux panel Panel Button Assignments VX40S 5 6 7 4 A7: OFF A7: ON 1=Mode 2=Temp Up 6=Unused 6=J17/26 A3: OFF 7=Unused 7=Unused 3=Temp Down 4=Light 6=Exp Pump 6=Exp Pump A3:ON 7=Unused 7=J17/26 5=Pump 1 http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 6 920-925-3094 54517-01_97_B
  • 7. Electrical Service Configuration Options Systems with PCB Rev B Only J50 AV J29 OZONE J23 PUMP 1 K9 K6 K1 F7 F10A 250V F1 J13 J52 J51 F6, T30A 480V J F3A 250V G N J46 Single Service, TN and TT Electrical Systems J47 CIRC. PUMP K8 K5 J20 N J25 5 G N C9 N N J32 2 (1 x 16 Amp or 1 x 32 Amp) G N G G G F3 TB1 10VAC 3 Wires (1 Line + 1 Neutral + 1J71Protective Earth) 10VAC J17/26 J72 1 F4, T0.2A 250V OPT. BLWR/PUMP 2 T1 J58 Protective Earth wire (Green/Yellow) must be connected to system ground terminal as marked. J2A J1A AS MANUFACTURED 2 J1 W2 J28 8 This option is configured and shipped as the default. J2 L1 3 J26 6 K3 All equipment (pumps, blower, and heater) runs on N1 service line L1. J18 1 4 J43 J10 K4 U4 J57 F2 Balboa J19 BALBOA INSTRUMENTS, INC. W1 HTR2 J101 HTR1 00 K2 J90 Systems using only 1 DIP switch (A10) for heat disable: S1 J6 J60 J7 J8 J44 J12 E.GND 1 1 GS500Z COPYRIGHT 2007 Pb Pb For 1 x 16 Amp Service: 1 1 1 J22 MADE IN U.S.A. TST 1 P/N 22015_B SWITCHBANK A EXT RLY AUX F SEN A SEN B VAC J11 DIP Switch A10 must be ON. For 1 x 32 Amp Service: Set DIP Switch A10 such that total system amperage draw never exceeds rated service input. Systems using multiple DIP switches for heat disable: Refer to system Hot Sheet DIP Switch Definition page and set the switches shown in Table 1 such that total system amperage draw never exceeds rated service input. AV F7 F1 J13 J50 J29 J23 K6 K1 F10A 250V OZONE PUMP 1 K9 J52 J51 F6, T30A 480V J F3A 250V G N J46 Dual Service, TN and TT Electrical Systems J47 CIRC. PUMP K8 K5 J20 N J25 5 G N C9 (2 x 16 Amp) N N G N J32 2 G G G F3 TB1 1 F4, T0.2A 250V 5 Wires (2 Lines10VAC 2 Neutrals + 1 Protective Earth) J17/26 + J72 OPT. BLWR/PUMP 2 J71 10VAC L2 T1 Protective Earth wire (Green/Yellow) must be connected J58 to system ground terminal as marked. J2A J1A N2 2 J1 W2 J28 8 The heater runs on service line L1, while all other J2 OPTIONAL L1 3 equipment, such as pumps and blowers, run on J26 6 K3 service line L2. N1 J18 1 4 J43 J10 K4 J57 Completely remove the white wire from J26 and J32. F2 U4 Balboa J19 BALBOA INSTRUMENTS, INC. W1 HTR2 J101 HTR1 00 K2 J90 Note: J32 and J25 are electrically identical. The white S1 J6 J60 J7 J8 J44 J12 E.GND 1 1 GS500Z COPYRIGHT 2007 Pb Pb wire may be attached to either terminal before removal. 1 1 1 J22 MADE IN U.S.A. TST 1 P/N 22015_B SWITCHBANK A EXT RLY AUX F SEN A SEN B VAC J11 Systems using only 1 DIP switch (A10) for heat disable: DIP Switch A10 must be OFF. Systems using multiple DIP switches for heat disable: Refer to system Hot Sheet DIP Switch Definition page and set both switches shown in Table 1 to ON positions. http://www.MyPoolSpas.com Wholesale Pool and Spa Parts Page 7 920-925-3094 54517-01_97_B