SlideShare a Scribd company logo
1 of 6
Download to read offline
Stress, Strain, and Strain Gages, Page 1
Stress, Strain, and Strain Gages
Author: John M. Cimbala, Penn State University
Latest revision: 24 October 2013
Introduction
 Stress and strain are important aspects of Mechanical Engineering, especially in structural design.
 In this learning module, we discuss stress and strain and their relationship, and how to measure them.
Definitions
 Stress
o When a material is loaded with a force, the stress at some location in the material is
defined as the applied force per unit of cross-sectional area.
o For example, consider a wire or cylinder, anchored at the top, and hanging down. Some
force F (for example, from a hanging weight) pulls at the bottom, as sketched, where A is
the original cross-sectional area of the wire, and L is the original wire length.
o In this situation, the material experiences a stress, called an axial stress, denoted by the
subscript a, and defined as a
F
A
  .
o Notice that the dimensions of stress are the same as those of pressure – force per
unit area.
 Strain
o In the above simple example, the wire stretches vertically as a result of the force.
Strain is defined as the ratio of increase in length to original length.
o Specifically, when force is applied to the wire, its length L increases by a small
increment L, while its cross-sectional area A decreases, as sketched.
o In the axial direction (the direction of the applied force), axial strain a is defined
as a
L
L

  .
o The dimensions of strain are unity – strain is a nondimensional quantity.
 Hooke’s law
o It turns out that for elastic materials, stress is linearly proportional to strain.
o Mathematically, this is expressed by Hooke’s law, which states a aE  , where E = Young’s modulus,
also called the modulus of elasticity.
o Young’s modulus is assumed to be constant for a given material.
o Hooke’s law breaks down when the strain gets too high. On a typical
stress-strain diagram, Hooke’s law applies only in the elastic stress
region, in which the loading is reversible. Beyond the elastic limit (or
proportional limit), the material starts to behave irreversibly in the
plastic deformation region, in which the stress vs. strain curve deviates
from linear, and Hooke’s law no longer holds, as sketched.
o In this learning module, only the elastic stress region is considered.
Wire resistance
 The electrical resistance R of a wire of length L and cross-sectional area A is given by
L
R
A

 , where  is
the resistivity of the wire material. (Do not confuse  with density, for which the same symbol is used.)
 The electrical resistance of the wire changes with strain:
o As strain increases, the wire length L increases, which increases R.
o As strain increases, the wire cross-sectional area A decreases, which increases R.
o For most materials, as strain increases, the wire resistivity  also increases, which further increases R.
 The bottom line is that wire resistance increases with strain.
 In fact, it turns out that at constant temperature, wire resistance increases linearly with strain.
 Mathematically, a
R
S
R

 , where S is the strain gage factor, defined as
/
a
R R
S


 .
 S is typically around 2.0 for commercially available strain gages. S is dimensionless.
F
A L
F
L + L
L
L
a
a
Elastic limit
Elastic stress
region
Yield
stress
Stress, Strain, and Strain Gages, Page 2
Strain gage
 The principle discussed above, namely that a wire’s resistance increases
with strain, is key to understanding how a strain gage works.
 The strain gage was invented by Ed Simmons at Caltech in 1936.
 A strain gage consists of a small diameter wire (actually an etched metal
foil) that is attached to a backing material (usually made of plastic) as
sketched. The wire is looped back and forth several times to create an
effectively longer wire. The longer the wire, the larger the resistance, and
the larger the change in resistance with strain.
 Here, four loops of metal foil are shown, providing an effective total foil
length L that is eight times greater than if a single wire, rather than a
looping pattern, were used. Commercially available strain gages have
even more loops than this. The ones used in our lab have six loops.
 The direction of the applied strain is indicated on the sketch. The
connecting wires or leads go to an electronic circuit (discussed below)
that measures the change in resistance.
 Consider a beam undergoing axial strain; the strain is to be measured.
 A strain gage is glued to the surface of the beam, with the long sections of the etched metal foil aligned with
the applied axial strain as sketched below left (the strain gage is mounted on the front face of the beam).
 As the surface stretches (strains), the strain gage stretches along with it. The resistance of the strain gage
therefore increases with applied strain. Assuming the change in resistance can be measured, the strain gage
provides a method for measuring strain.
 Other practical applications are shown below – a strain gage glued (rather sloppily) onto a cylindrical rod,
and a strain gage mounted on a re-bar, which is then encased in concrete, used to measure shrinkage and to
monitor the strain on structural components in bridges, buildings, etc.
F
Strain
gage
Beam
Typical strain gage values
 Here are some typical values for resistance, strain gage factor, and strain, along with the predicted values of
change in resistance:
o The electrical resistance R of a commercial strain gage (with no applied strain) is typically either 120 
or 350 .
o The most widely used commercially available strain gages have R = 120 .
o The strain gage factor S of the metal foil used in strain gages is typically around 2.0.
o In typical engineering applications with metal beams, the range of axial strain is 10-6
< a < 10-3
.
 Using these limits and the above equation for change in resistance as a function of strain and strain gage
factor, aR RS  , and the typical range of R is        6 3
120 2.0 10 120 2.0 10R 
    , or
0.00024  < R < 0.24 .
 Notice how small R is!
 For a typical 120  strain gage, the range of fractional change in resistance is 2  10-6
< R/R < 2  10-3
.
 This is the main problem when working with strain gages: We cannot use a simple ohm meter to measure the
change in resistance, because R/R is so small. Most ohm meters do not have sufficient resolution to measure
changes in resistance that are 3 to 6 orders of magnitude smaller than the resistance itself.
Etched
metal foil
Backing
material
Connecting wires
(leads)
Direction
of strain
Solder
terminal
Stress, Strain, and Strain Gages, Page 3
Strain gage electronics
Since R/R is very small and difficult to measure directly, electronic circuits must be designed to measure the change
in resistance rather than the resistance itself. Fortunately, there are circuits available to do just that.
The Wheatstone bridge
 A clever circuit to measure very small changes in resistance is called a Wheatstone bridge.
 A schematic diagram of a simple Wheatstone bridge circuit is shown to
the right.
 As seen in the sketch, a DC supply voltage is supplied (top to bottom)
across the bridge, which contains four resistors (two parallel legs of two
resistors each in series).
 The output voltage is measured across the legs in the middle of the
bridge.
 In the analysis here, it is assumed that the measuring device (voltmeter,
oscilloscope, computerized digital data acquisition system, etc.) used to measure output voltage Vo has an
infinite input impedance, and therefore has no effect on the circuit.
 Output voltage Vo = Vo
+
– Vo
–
is calculated by analyzing the circuit. Namely,
  
3 1 4 2
o
2 3 1 4
s
R R R R
V V
R R R R


 
.
[This equation is “exact” – no approximations of small change in resistance were made in its derivation.]
 How does the Wheatstone bridge work? Well, if all four resistors are identical (R1 = R2 = R3 = R4), the bridge
is balanced since the same current flows through the left leg and the right leg of the bridge. For a balanced
bridge, Vo = 0.
 More generally (as can be seen from the above equation), a Wheatstone bridge can be balanced even if the
resistors do not all have the same value, so long as the numerator in the above equation is zero, i.e., if
3 1 4 2R R R R . Or, expressed as ratios, the bridge is balanced if 1 4
2 3
R R
R R
 .
 In practice, the bridge will not be balanced automatically, since “identical” resistors are not actually
identical, with resistance varying by up to several percent. Thus, a potentiometer (variable resistor) is
sometimes applied in place of one of the resistors in the bridge so that
minor adjustments can be made in order to balance the bridge.
o An arrow through the resistor indicates that its resistance can vary,
as sketched to the right.
o In this circuit, resistor R2 was arbitrarily chosen to be replaced by a
potentiometer, but any of the four resistors could have been used
instead.
Quarter bridge circuit
 To measure strain, one of the resistors, in this case R3, is replaced by the
strain gage, as sketched to the right. (Note that one of the other resistors
may still be a potentiometer rather than a fixed resistor, but that will not
be indicated on the circuit diagrams to follow.)
 Again, an arrow through the resistor indicates that its resistance can
vary  this time because R3 is an active strain gage, not a potentiometer.
 With only one out of the four available resistors substituted by a strain
gage, as in the above schematic, the circuit is called a quarter bridge
circuit.
 The output voltage Vo is calculated from Ohm’s law, as previously,
  
3 1 4 2
o
2 3 1 4
s
R R R R
V V
R R R R


 
.
 Let R1 = R2 = R4 = 120 , and let the initial resistance of the strain gage (with no load) be R3,initial = 120 .
 The bridge is therefore initially balanced when R3 = R3,initial, since R3,initialR1 – R4R2 = 0, and Vo is thus zero.
Vs = supply
voltage
R1 R2
R4 R3
Vo
+

+

Pot
Vs = supply
voltage
R1 R2
R4 R3
Vo
+
+

R3 = strain gage
Vs = supply
voltage
R1 R2
R4 R3
Vo
+
+

Vo
–
Vo
+
Stress, Strain, and Strain Gages, Page 4
Unbalanced quarter bridge circuit - to measure strain
 In normal operation, the Wheatstone bridge is initially balanced as above. Now suppose strain is applied to
the strain gage, such that its resistance changes by some small amount R3. In other words, R3 changes from
R3,initial to R3,initial + R3.
 Under these conditions the bridge is unbalanced, and the resulting output voltage Vo is not zero, but can be
calculated as
 
  
3,initial 3 1 4 2
o
2 3,initial 3 1 4
s
R R R R R
V V
R R R R R


 

  
.
 We simplify the numerator by applying the initial balance equation, R3,initialR1 – R4R2 = 0, yielding
  
3 1
o
2 3,initial 3 1 4
s
R R
V V
R R R R R




  
. [This equation is exact only if the bridge is initially balanced.]
 We simplify the denominator by recognizing, as pointed out previously, that the change in resistance of a
strain gage is very small; in other words, R3/R3,initial << 1. This yields
  
3 1
o
2 3,initial 1 4
s
R R
V V
R R R R
 

 
.
 We apply the relationship derived earlier for change in resistance of a strain gage as a function of axial strain,
resistance, and strain gage factor, namely, 3 3,initial aR R S  . After some algebra,
 
2
2 3,initialo
2 3,initial
1
a
s
R RV
V S R R


 .
 Furthermore, since R2 = R3,initial (e.g., both are 120 ), this reduces to o 1
4a
s
V
V S
  or o
4
a
s
S
V V

 .
 The significance of this result is this:
For constant supply voltage Vs and constant strain gage factor S, axial strain at the location of the strain gage
is a linear function of the output voltage from the Wheatstone bridge circuit.
 Even more significantly:
For known values of S and Vs, the actual value of the strain can be calculated from the above equation after
measurement of output voltage Vo.
 Example:
Given: A standard strain gage is used in a quarter bridge circuit to measure the strain of a beam in tension.
The strain gage factor is S = 2.0, and the supply voltage to the Wheatstone bridge is Vs = 5.00 V. The
bridge is balanced when no load is applied. Assume all resistors are equal when the strain gage circuit is
initially balanced with no load. For a certain non-zero load, the measured output voltage is Vo = 1.13 mV.
To do: Calculate the axial strain on the beam.
Solution:
o We apply the above equation for axial strain for a quarter bridge circuit, yielding
o 1 1.13 mV 1 1 V
4 4
5.00 V 2.0 1000 mV
a
s
V
V S

 
   
 
= 0.000452.
o Since strain is such a small number, it is common to report strain in units of microstrain (strain),
defined as the strain times 106
. Note that strain is dimensionless, so microstrain is a dimensionless unit.
o The unit conversion between strain and microstrain, expressed as a
dimensionless ratio, is (106
microstrain/strain). Thus,
6
10 strain
0.000452
strain
a


 
  
 
= 452 strain.
o Finally, keeping to two significant digits (since S is given to only two digits),
450 straina  .
Discussion: It is also correct to give the final answer as 0.00045a  .
Half bridge circuit
 Suppose we mount two active strain gages on the beam, one at the front and one
at the back as sketched to the right.
 Also suppose that both strain gages are put into the Wheatstone bridge circuit, as
shown in the circuit diagram below, noting that resistors R1 and R3 have been
Front
strain
gage
Beam
Rear
strain
gage
F
Stress, Strain, and Strain Gages, Page 5
replaced by the two strain gages.
 Since half of the four available resistors in the bridge are strain gages, this is called a half bridge circuit.
 After some algebra, assuming that both strain gage resistances change identically as the strain is applied, it
can be shown that
 
2
2 3,initialo
2 3,initial
1
2
a
s
R RV
V S R R


 .
 Furthermore, since R2 = R3,initial = 120 , the above equation reduces to
o 1
2a
s
V
V S
  or o
2
a
s
S
V V

 .
 Compared to the quarter bridge circuit, the half bridge circuit yields
twice the output voltage for a given strain. We say that the sensitivity of
the circuit has improved by a factor of two.
 You might ask why R1 (rather than R2 or R4) was chosen as the resistor
to replace with the second strain gage. It turns out that R1 is used for the
second strain gage if its strain is of the same sign as that of R3.
 To prove the above statement, suppose all four resistors are strain gages
with initial values R1,initial, R2,initial, etc. The corresponding changes in resistance due to applied strain are R1,
R2, etc. It can be shown (via application of Ohm’s law, and neglecting higher-order terms as previously) that
the output voltage varies as
 
2,initial 3,initialo 31 2 4
2
1,initial 2,initial 3,initial 4,initial2,initial 3,initials
R RV RR R R
V R R R RR R
   
     
  
. [This equation is
approximate – assumes initially balanced bridge and small changes in resistance.]
 As can be seen, the terms with R1 and R3 are of positive sign, and therefore contribute to a positive output
voltage when the applied strain is positive (strain gage in tension).
 However, the terms with R2 and R4 are of negative sign, and therefore contribute to a negative output
voltage when the applied strain is positive (strain gage in tension).
 In the above beam example, in which both strain gages measure the same strain, it is appropriate to choose R1
for the second strain gage. If R2 or R4 had been chosen instead, the output voltage would not change at all as
strain is increased, because of the signs in the above equation. (The change in resistance of the two strain
gages would cancel each other out!)
Example  a cantilever beam experiment
 As an example, consider a simple
lab experiment. A cantilevered
beam is clamped to the lab bench,
and a weight is applied at the end
of the beam as sketched to the
right. A strain gage is attached on
the top surface of the beam, and
another is attached at the bottom surface, as shown.
 As the beam is strained due to the applied force, the top strain gage is stretched (positive axial strain), but
the bottom strain gage is compressed (negative axial strain).
 If the beam is symmetric in cross section, and if the two strain gages are identical, the two strain gages have
approximately the same magnitude of change in resistance, but opposite signs, i.e., Rbottom = Rtop.
 In this case, if R1 and R3 were chosen for the two strain gages in the bridge circuit, the Wheatstone bridge
would remain balanced for any applied load, since R1 and R3
would cancel each other out.
 In this example, the half bridge circuit should be constructed with
pairs of resistors that have opposite signs in the above general
equation – the choices are R1 and R2, R1 and R4, R2 and R3, or R3
and R4 as the two resistors to be substituted by the strain gages.
 An example circuit for this simple experiment uses R3 for the top
strain gage and R4 for the bottom strain gage, with the Wheatstone
bridge circuit wired as sketched to the right.
Bench
Clamp
Strain gages (on top and bottom)
F
Cantilevered beam
Vs = supply
voltage
R1 R2
Vo
+
+

R3 = top
strain gage
R4 = bottom
strain gage
Vs = supply
voltage
R1 R2
R4 R3
Vo
+
+

R1 = strain gage
R3 = strain gage
Stress, Strain, and Strain Gages, Page 6
 Circuit analysis for this case yields o 1
2a
s
V
V S
  or o
2
a
s
S
V V

 .
 Compared to the quarter bridge circuit, the voltage output of this half bridge circuit (with two active strain
gages) is twice that of the quarter bridge circuit (with only one active strain gage), all else being equal.
 For any system, sensitivity is defined as (change in output) / (change in input). In this case, the output is the
voltage Vo, and the input is the axial strain being measured.
 Thus, we conclude: The sensitivity of a half bridge Wheatstone bridge circuit is twice that of a quarter bridge
Wheatstone bridge circuit.
Full bridge circuit
 If we substitute strain gages for all four resistors in a Wheatstone
bridge, the result is called a full bridge circuit, as sketched to the right.
 Warning: You need to be very careful with the signs when wiring a full
bridge circuit!
 If the wiring is done properly (e.g., R1 and R3 have positive strain, while
R2 and R4 have negative strain), the sensitivity of the full bridge circuit
is four times that of a quarter bridge circuit, o 1
a
s
V
V S
  or o a sV SV .
 In general, we define n as the number of active gages in the Wheatstone bridge:
o n = 1 for a quarter bridge
o n = 2 for a half bridge
o n = 4 for a full bridge
 Then the strain can be generalized to o4 1
a
s
V
n V S
  or o
4
a s
n
V SV .
 One cautionary note: In derivation of the above equation, it is assumed that positive strain gages (R1 and R3)
are chosen for positive strain (tension), and negative strain gages (R2 and R4) are chosen for negative strain
(compression). If instead we were to wire the circuit such that the positive gages are in compression and the
negative gages are in tension, a negative sign would appear in the above equation.
 On a final note, it is not always necessary to initially balance the bridge. In other words, suppose there is
some initial non-zero value of bridge output voltage, namely Vo,reference  0. This voltage represents the
reference output voltage at some initial conditions of the experiment, which may not necessarily even be
zero strain.
 We can still calculate the strain by using the output voltage difference rather than the output voltage itself,
 o o,reference4 1
a
s
V V
n V S


 or o o,reference
4
a s
n
V V SV  .
 In the lab, we use voltmeters with a “REL” button, which stands for “relative” voltage. [On some voltmeters,
the REL button is indicated by triangular symbol “” instead.]
 Under conditions of zero strain with a slightly unbalanced bridge, the reference output voltage is not zero
(Vo,reference  0). However, pushing the REL button causes the voltmeter to read all subsequent voltages
relative to Vo,reference. In other words, the voltmeter reads Vo – Vo,reference instead of Vo itself. We effectively
“trick” the voltmeter into showing zero voltage for zero strain.
 Warning: The REL button can be dangerous if you forget to turn it off, because all subsequent voltages are
displayed relative to the voltage input at the time the REL button was pushed.
Vs = supply
voltage
R1 R2
R4 R3
Vo
+
+


More Related Content

What's hot

Ce6306 strength of materials
Ce6306 strength of materialsCe6306 strength of materials
Ce6306 strength of materialsSiddhu Siddhu
 
mechanics of solids
mechanics of solidsmechanics of solids
mechanics of solidsGowtham Raja
 
Mechanics Of Solids- Stress Transformation in 3D
Mechanics Of Solids- Stress Transformation in 3DMechanics Of Solids- Stress Transformation in 3D
Mechanics Of Solids- Stress Transformation in 3DShaheryar Ahmad
 
Stress and strain- mechanics of solid
Stress and strain- mechanics of solidStress and strain- mechanics of solid
Stress and strain- mechanics of solidKaushal Patel
 
Stressanalysis linearityerror
Stressanalysis linearityerrorStressanalysis linearityerror
Stressanalysis linearityerrorNobantuNxumalo
 
MH-67-RANKINE'S HYPOTHESIS.
MH-67-RANKINE'S HYPOTHESIS.MH-67-RANKINE'S HYPOTHESIS.
MH-67-RANKINE'S HYPOTHESIS.Dhaval Sukhadia
 
An Experiment to Verify Ohm's Law
An Experiment to Verify Ohm's LawAn Experiment to Verify Ohm's Law
An Experiment to Verify Ohm's Lawbernadettevania
 
Sample lab-report on verfication of ohms law
Sample lab-report on verfication of ohms lawSample lab-report on verfication of ohms law
Sample lab-report on verfication of ohms lawminteshat
 
Chapter 33
Chapter 33Chapter 33
Chapter 33mcfalltj
 
Lec4 shear of thin walled beams
Lec4 shear of thin walled beamsLec4 shear of thin walled beams
Lec4 shear of thin walled beamsMahdi Damghani
 
Sagcalculation 170523032311-converted
Sagcalculation 170523032311-convertedSagcalculation 170523032311-converted
Sagcalculation 170523032311-convertedDeepthi Shibuz
 
Lecture 1 stresses and strains
Lecture 1 stresses and strainsLecture 1 stresses and strains
Lecture 1 stresses and strainsDeepak Agarwal
 
TALAT Lecture 3701: Formability Characteristics of Aluminium Sheet
TALAT Lecture 3701: Formability Characteristics of Aluminium SheetTALAT Lecture 3701: Formability Characteristics of Aluminium Sheet
TALAT Lecture 3701: Formability Characteristics of Aluminium SheetCORE-Materials
 
519 transmission line theory by vishnu (1)
519 transmission line theory by vishnu (1)519 transmission line theory by vishnu (1)
519 transmission line theory by vishnu (1)udaykumar1106
 
Phys 102 formal simple dc circuits lab report
Phys 102 formal simple dc circuits lab reportPhys 102 formal simple dc circuits lab report
Phys 102 formal simple dc circuits lab reportkgreine
 

What's hot (20)

Ce6306 strength of materials
Ce6306 strength of materialsCe6306 strength of materials
Ce6306 strength of materials
 
Ppt springs
Ppt springsPpt springs
Ppt springs
 
10 columns
10 columns10 columns
10 columns
 
mechanics of solids
mechanics of solidsmechanics of solids
mechanics of solids
 
Mechanics Of Solids- Stress Transformation in 3D
Mechanics Of Solids- Stress Transformation in 3DMechanics Of Solids- Stress Transformation in 3D
Mechanics Of Solids- Stress Transformation in 3D
 
Stress and strain- mechanics of solid
Stress and strain- mechanics of solidStress and strain- mechanics of solid
Stress and strain- mechanics of solid
 
Stressanalysis linearityerror
Stressanalysis linearityerrorStressanalysis linearityerror
Stressanalysis linearityerror
 
MH-67-RANKINE'S HYPOTHESIS.
MH-67-RANKINE'S HYPOTHESIS.MH-67-RANKINE'S HYPOTHESIS.
MH-67-RANKINE'S HYPOTHESIS.
 
AC Theory
AC TheoryAC Theory
AC Theory
 
An Experiment to Verify Ohm's Law
An Experiment to Verify Ohm's LawAn Experiment to Verify Ohm's Law
An Experiment to Verify Ohm's Law
 
Sample lab-report on verfication of ohms law
Sample lab-report on verfication of ohms lawSample lab-report on verfication of ohms law
Sample lab-report on verfication of ohms law
 
Chapter 33
Chapter 33Chapter 33
Chapter 33
 
Lec4 shear of thin walled beams
Lec4 shear of thin walled beamsLec4 shear of thin walled beams
Lec4 shear of thin walled beams
 
Sagcalculation 170523032311-converted
Sagcalculation 170523032311-convertedSagcalculation 170523032311-converted
Sagcalculation 170523032311-converted
 
Lecture 1 stresses and strains
Lecture 1 stresses and strainsLecture 1 stresses and strains
Lecture 1 stresses and strains
 
Long report fizik
Long report fizikLong report fizik
Long report fizik
 
Spring test
Spring testSpring test
Spring test
 
TALAT Lecture 3701: Formability Characteristics of Aluminium Sheet
TALAT Lecture 3701: Formability Characteristics of Aluminium SheetTALAT Lecture 3701: Formability Characteristics of Aluminium Sheet
TALAT Lecture 3701: Formability Characteristics of Aluminium Sheet
 
519 transmission line theory by vishnu (1)
519 transmission line theory by vishnu (1)519 transmission line theory by vishnu (1)
519 transmission line theory by vishnu (1)
 
Phys 102 formal simple dc circuits lab report
Phys 102 formal simple dc circuits lab reportPhys 102 formal simple dc circuits lab report
Phys 102 formal simple dc circuits lab report
 

Similar to Strain gages

Introduction to-strain-gauges-and-their-usage
Introduction to-strain-gauges-and-their-usageIntroduction to-strain-gauges-and-their-usage
Introduction to-strain-gauges-and-their-usageAli Abd Ellatief
 
5.2 heating effect of currents
5.2 heating effect of currents5.2 heating effect of currents
5.2 heating effect of currentsPaula Mills
 
5.2 heating effect of currents
5.2 heating effect of currents5.2 heating effect of currents
5.2 heating effect of currentsPaula Mills
 
Strain Measurement.pdf
Strain Measurement.pdfStrain Measurement.pdf
Strain Measurement.pdfGopalakrishnaU
 
Current Electricity.pptx
Current Electricity.pptxCurrent Electricity.pptx
Current Electricity.pptxPooja M
 
EXPERIMENTAL STRESS ANALYSIS CHAPTER-01
EXPERIMENTAL STRESS ANALYSIS CHAPTER-01EXPERIMENTAL STRESS ANALYSIS CHAPTER-01
EXPERIMENTAL STRESS ANALYSIS CHAPTER-01MAHESH HUDALI
 
Strain gauge hardik
Strain gauge hardikStrain gauge hardik
Strain gauge hardikHardik Jain
 
Electric transducer
Electric transducerElectric transducer
Electric transducerUday Korat
 
Experimental strain analysis
Experimental strain analysisExperimental strain analysis
Experimental strain analysisKanok Phoocam
 
Grade 11, U3 L3-Resistance-in-conductors
Grade 11, U3 L3-Resistance-in-conductorsGrade 11, U3 L3-Resistance-in-conductors
Grade 11, U3 L3-Resistance-in-conductorsgruszecki1
 
Intro to Electricity.pdf
Intro to Electricity.pdfIntro to Electricity.pdf
Intro to Electricity.pdfDavidKimunyan
 
Intro to Electricity.ppt
Intro to Electricity.pptIntro to Electricity.ppt
Intro to Electricity.pptjohnjacobcabal
 

Similar to Strain gages (20)

Resistive Sensors
Resistive SensorsResistive Sensors
Resistive Sensors
 
Introduction to-strain-gauges-and-their-usage
Introduction to-strain-gauges-and-their-usageIntroduction to-strain-gauges-and-their-usage
Introduction to-strain-gauges-and-their-usage
 
5.2 heating effect of currents
5.2 heating effect of currents5.2 heating effect of currents
5.2 heating effect of currents
 
5.2 heating effect of currents
5.2 heating effect of currents5.2 heating effect of currents
5.2 heating effect of currents
 
SImple strain.pdf
SImple strain.pdfSImple strain.pdf
SImple strain.pdf
 
Strain measurement
Strain measurementStrain measurement
Strain measurement
 
Strain Measurement.pdf
Strain Measurement.pdfStrain Measurement.pdf
Strain Measurement.pdf
 
Current Electricity.pptx
Current Electricity.pptxCurrent Electricity.pptx
Current Electricity.pptx
 
EXPERIMENTAL STRESS ANALYSIS CHAPTER-01
EXPERIMENTAL STRESS ANALYSIS CHAPTER-01EXPERIMENTAL STRESS ANALYSIS CHAPTER-01
EXPERIMENTAL STRESS ANALYSIS CHAPTER-01
 
Four probe-method
Four probe-methodFour probe-method
Four probe-method
 
Current electricity
Current electricityCurrent electricity
Current electricity
 
Strain gauge hardik
Strain gauge hardikStrain gauge hardik
Strain gauge hardik
 
Electric transducer
Electric transducerElectric transducer
Electric transducer
 
Experimental strain analysis
Experimental strain analysisExperimental strain analysis
Experimental strain analysis
 
Mm210(4)
Mm210(4)Mm210(4)
Mm210(4)
 
Mesh and nodal
Mesh and nodalMesh and nodal
Mesh and nodal
 
Grade 11, U3 L3-Resistance-in-conductors
Grade 11, U3 L3-Resistance-in-conductorsGrade 11, U3 L3-Resistance-in-conductors
Grade 11, U3 L3-Resistance-in-conductors
 
Strain Gauges
Strain GaugesStrain Gauges
Strain Gauges
 
Intro to Electricity.pdf
Intro to Electricity.pdfIntro to Electricity.pdf
Intro to Electricity.pdf
 
Intro to Electricity.ppt
Intro to Electricity.pptIntro to Electricity.ppt
Intro to Electricity.ppt
 

More from yared seifu

Ece 371 jb lecture 3
Ece 371 jb lecture 3Ece 371 jb lecture 3
Ece 371 jb lecture 3yared seifu
 
Traction and tractor_performance
Traction and tractor_performanceTraction and tractor_performance
Traction and tractor_performanceyared seifu
 
Photoelectric detectors xs
Photoelectric detectors xsPhotoelectric detectors xs
Photoelectric detectors xsyared seifu
 
soil properties-hayes
soil properties-hayessoil properties-hayes
soil properties-hayesyared seifu
 
Helical gears formulas
Helical gears formulasHelical gears formulas
Helical gears formulasyared seifu
 

More from yared seifu (9)

Ece 371 jb lecture 3
Ece 371 jb lecture 3Ece 371 jb lecture 3
Ece 371 jb lecture 3
 
Traction and tractor_performance
Traction and tractor_performanceTraction and tractor_performance
Traction and tractor_performance
 
Whats
WhatsWhats
Whats
 
V4 145-148
V4 145-148V4 145-148
V4 145-148
 
Photoelectric detectors xs
Photoelectric detectors xsPhotoelectric detectors xs
Photoelectric detectors xs
 
Lm 10
Lm 10Lm 10
Lm 10
 
soil properties-hayes
soil properties-hayessoil properties-hayes
soil properties-hayes
 
Raerest me 198
Raerest me 198Raerest me 198
Raerest me 198
 
Helical gears formulas
Helical gears formulasHelical gears formulas
Helical gears formulas
 

Recently uploaded

Past, Present and Future of Generative AI
Past, Present and Future of Generative AIPast, Present and Future of Generative AI
Past, Present and Future of Generative AIabhishek36461
 
chaitra-1.pptx fake news detection using machine learning
chaitra-1.pptx  fake news detection using machine learningchaitra-1.pptx  fake news detection using machine learning
chaitra-1.pptx fake news detection using machine learningmisbanausheenparvam
 
Gurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort service
Gurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort serviceGurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort service
Gurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort servicejennyeacort
 
Biology for Computer Engineers Course Handout.pptx
Biology for Computer Engineers Course Handout.pptxBiology for Computer Engineers Course Handout.pptx
Biology for Computer Engineers Course Handout.pptxDeepakSakkari2
 
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...Soham Mondal
 
microprocessor 8085 and its interfacing
microprocessor 8085  and its interfacingmicroprocessor 8085  and its interfacing
microprocessor 8085 and its interfacingjaychoudhary37
 
Call Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile serviceCall Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile servicerehmti665
 
IVE Industry Focused Event - Defence Sector 2024
IVE Industry Focused Event - Defence Sector 2024IVE Industry Focused Event - Defence Sector 2024
IVE Industry Focused Event - Defence Sector 2024Mark Billinghurst
 
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...VICTOR MAESTRE RAMIREZ
 
Call Girls Narol 7397865700 Independent Call Girls
Call Girls Narol 7397865700 Independent Call GirlsCall Girls Narol 7397865700 Independent Call Girls
Call Girls Narol 7397865700 Independent Call Girlsssuser7cb4ff
 
Sachpazis Costas: Geotechnical Engineering: A student's Perspective Introduction
Sachpazis Costas: Geotechnical Engineering: A student's Perspective IntroductionSachpazis Costas: Geotechnical Engineering: A student's Perspective Introduction
Sachpazis Costas: Geotechnical Engineering: A student's Perspective IntroductionDr.Costas Sachpazis
 
Microscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptxMicroscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptxpurnimasatapathy1234
 
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube ExchangerStudy on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube ExchangerAnamika Sarkar
 
Application of Residue Theorem to evaluate real integrations.pptx
Application of Residue Theorem to evaluate real integrations.pptxApplication of Residue Theorem to evaluate real integrations.pptx
Application of Residue Theorem to evaluate real integrations.pptx959SahilShah
 
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
 
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Dr.Costas Sachpazis
 
Heart Disease Prediction using machine learning.pptx
Heart Disease Prediction using machine learning.pptxHeart Disease Prediction using machine learning.pptx
Heart Disease Prediction using machine learning.pptxPoojaBan
 

Recently uploaded (20)

Past, Present and Future of Generative AI
Past, Present and Future of Generative AIPast, Present and Future of Generative AI
Past, Present and Future of Generative AI
 
chaitra-1.pptx fake news detection using machine learning
chaitra-1.pptx  fake news detection using machine learningchaitra-1.pptx  fake news detection using machine learning
chaitra-1.pptx fake news detection using machine learning
 
Exploring_Network_Security_with_JA3_by_Rakesh Seal.pptx
Exploring_Network_Security_with_JA3_by_Rakesh Seal.pptxExploring_Network_Security_with_JA3_by_Rakesh Seal.pptx
Exploring_Network_Security_with_JA3_by_Rakesh Seal.pptx
 
Gurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort service
Gurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort serviceGurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort service
Gurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort service
 
Biology for Computer Engineers Course Handout.pptx
Biology for Computer Engineers Course Handout.pptxBiology for Computer Engineers Course Handout.pptx
Biology for Computer Engineers Course Handout.pptx
 
🔝9953056974🔝!!-YOUNG call girls in Rajendra Nagar Escort rvice Shot 2000 nigh...
🔝9953056974🔝!!-YOUNG call girls in Rajendra Nagar Escort rvice Shot 2000 nigh...🔝9953056974🔝!!-YOUNG call girls in Rajendra Nagar Escort rvice Shot 2000 nigh...
🔝9953056974🔝!!-YOUNG call girls in Rajendra Nagar Escort rvice Shot 2000 nigh...
 
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
 
microprocessor 8085 and its interfacing
microprocessor 8085  and its interfacingmicroprocessor 8085  and its interfacing
microprocessor 8085 and its interfacing
 
Call Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile serviceCall Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile service
 
IVE Industry Focused Event - Defence Sector 2024
IVE Industry Focused Event - Defence Sector 2024IVE Industry Focused Event - Defence Sector 2024
IVE Industry Focused Event - Defence Sector 2024
 
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...
VICTOR MAESTRE RAMIREZ - Planetary Defender on NASA's Double Asteroid Redirec...
 
Call Girls Narol 7397865700 Independent Call Girls
Call Girls Narol 7397865700 Independent Call GirlsCall Girls Narol 7397865700 Independent Call Girls
Call Girls Narol 7397865700 Independent Call Girls
 
Sachpazis Costas: Geotechnical Engineering: A student's Perspective Introduction
Sachpazis Costas: Geotechnical Engineering: A student's Perspective IntroductionSachpazis Costas: Geotechnical Engineering: A student's Perspective Introduction
Sachpazis Costas: Geotechnical Engineering: A student's Perspective Introduction
 
Microscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptxMicroscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptx
 
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube ExchangerStudy on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
 
Application of Residue Theorem to evaluate real integrations.pptx
Application of Residue Theorem to evaluate real integrations.pptxApplication of Residue Theorem to evaluate real integrations.pptx
Application of Residue Theorem to evaluate real integrations.pptx
 
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
 
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
 
Heart Disease Prediction using machine learning.pptx
Heart Disease Prediction using machine learning.pptxHeart Disease Prediction using machine learning.pptx
Heart Disease Prediction using machine learning.pptx
 
9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf
9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf
9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf
 

Strain gages

  • 1. Stress, Strain, and Strain Gages, Page 1 Stress, Strain, and Strain Gages Author: John M. Cimbala, Penn State University Latest revision: 24 October 2013 Introduction  Stress and strain are important aspects of Mechanical Engineering, especially in structural design.  In this learning module, we discuss stress and strain and their relationship, and how to measure them. Definitions  Stress o When a material is loaded with a force, the stress at some location in the material is defined as the applied force per unit of cross-sectional area. o For example, consider a wire or cylinder, anchored at the top, and hanging down. Some force F (for example, from a hanging weight) pulls at the bottom, as sketched, where A is the original cross-sectional area of the wire, and L is the original wire length. o In this situation, the material experiences a stress, called an axial stress, denoted by the subscript a, and defined as a F A   . o Notice that the dimensions of stress are the same as those of pressure – force per unit area.  Strain o In the above simple example, the wire stretches vertically as a result of the force. Strain is defined as the ratio of increase in length to original length. o Specifically, when force is applied to the wire, its length L increases by a small increment L, while its cross-sectional area A decreases, as sketched. o In the axial direction (the direction of the applied force), axial strain a is defined as a L L    . o The dimensions of strain are unity – strain is a nondimensional quantity.  Hooke’s law o It turns out that for elastic materials, stress is linearly proportional to strain. o Mathematically, this is expressed by Hooke’s law, which states a aE  , where E = Young’s modulus, also called the modulus of elasticity. o Young’s modulus is assumed to be constant for a given material. o Hooke’s law breaks down when the strain gets too high. On a typical stress-strain diagram, Hooke’s law applies only in the elastic stress region, in which the loading is reversible. Beyond the elastic limit (or proportional limit), the material starts to behave irreversibly in the plastic deformation region, in which the stress vs. strain curve deviates from linear, and Hooke’s law no longer holds, as sketched. o In this learning module, only the elastic stress region is considered. Wire resistance  The electrical resistance R of a wire of length L and cross-sectional area A is given by L R A   , where  is the resistivity of the wire material. (Do not confuse  with density, for which the same symbol is used.)  The electrical resistance of the wire changes with strain: o As strain increases, the wire length L increases, which increases R. o As strain increases, the wire cross-sectional area A decreases, which increases R. o For most materials, as strain increases, the wire resistivity  also increases, which further increases R.  The bottom line is that wire resistance increases with strain.  In fact, it turns out that at constant temperature, wire resistance increases linearly with strain.  Mathematically, a R S R   , where S is the strain gage factor, defined as / a R R S    .  S is typically around 2.0 for commercially available strain gages. S is dimensionless. F A L F L + L L L a a Elastic limit Elastic stress region Yield stress
  • 2. Stress, Strain, and Strain Gages, Page 2 Strain gage  The principle discussed above, namely that a wire’s resistance increases with strain, is key to understanding how a strain gage works.  The strain gage was invented by Ed Simmons at Caltech in 1936.  A strain gage consists of a small diameter wire (actually an etched metal foil) that is attached to a backing material (usually made of plastic) as sketched. The wire is looped back and forth several times to create an effectively longer wire. The longer the wire, the larger the resistance, and the larger the change in resistance with strain.  Here, four loops of metal foil are shown, providing an effective total foil length L that is eight times greater than if a single wire, rather than a looping pattern, were used. Commercially available strain gages have even more loops than this. The ones used in our lab have six loops.  The direction of the applied strain is indicated on the sketch. The connecting wires or leads go to an electronic circuit (discussed below) that measures the change in resistance.  Consider a beam undergoing axial strain; the strain is to be measured.  A strain gage is glued to the surface of the beam, with the long sections of the etched metal foil aligned with the applied axial strain as sketched below left (the strain gage is mounted on the front face of the beam).  As the surface stretches (strains), the strain gage stretches along with it. The resistance of the strain gage therefore increases with applied strain. Assuming the change in resistance can be measured, the strain gage provides a method for measuring strain.  Other practical applications are shown below – a strain gage glued (rather sloppily) onto a cylindrical rod, and a strain gage mounted on a re-bar, which is then encased in concrete, used to measure shrinkage and to monitor the strain on structural components in bridges, buildings, etc. F Strain gage Beam Typical strain gage values  Here are some typical values for resistance, strain gage factor, and strain, along with the predicted values of change in resistance: o The electrical resistance R of a commercial strain gage (with no applied strain) is typically either 120  or 350 . o The most widely used commercially available strain gages have R = 120 . o The strain gage factor S of the metal foil used in strain gages is typically around 2.0. o In typical engineering applications with metal beams, the range of axial strain is 10-6 < a < 10-3 .  Using these limits and the above equation for change in resistance as a function of strain and strain gage factor, aR RS  , and the typical range of R is        6 3 120 2.0 10 120 2.0 10R      , or 0.00024  < R < 0.24 .  Notice how small R is!  For a typical 120  strain gage, the range of fractional change in resistance is 2  10-6 < R/R < 2  10-3 .  This is the main problem when working with strain gages: We cannot use a simple ohm meter to measure the change in resistance, because R/R is so small. Most ohm meters do not have sufficient resolution to measure changes in resistance that are 3 to 6 orders of magnitude smaller than the resistance itself. Etched metal foil Backing material Connecting wires (leads) Direction of strain Solder terminal
  • 3. Stress, Strain, and Strain Gages, Page 3 Strain gage electronics Since R/R is very small and difficult to measure directly, electronic circuits must be designed to measure the change in resistance rather than the resistance itself. Fortunately, there are circuits available to do just that. The Wheatstone bridge  A clever circuit to measure very small changes in resistance is called a Wheatstone bridge.  A schematic diagram of a simple Wheatstone bridge circuit is shown to the right.  As seen in the sketch, a DC supply voltage is supplied (top to bottom) across the bridge, which contains four resistors (two parallel legs of two resistors each in series).  The output voltage is measured across the legs in the middle of the bridge.  In the analysis here, it is assumed that the measuring device (voltmeter, oscilloscope, computerized digital data acquisition system, etc.) used to measure output voltage Vo has an infinite input impedance, and therefore has no effect on the circuit.  Output voltage Vo = Vo + – Vo – is calculated by analyzing the circuit. Namely,    3 1 4 2 o 2 3 1 4 s R R R R V V R R R R     . [This equation is “exact” – no approximations of small change in resistance were made in its derivation.]  How does the Wheatstone bridge work? Well, if all four resistors are identical (R1 = R2 = R3 = R4), the bridge is balanced since the same current flows through the left leg and the right leg of the bridge. For a balanced bridge, Vo = 0.  More generally (as can be seen from the above equation), a Wheatstone bridge can be balanced even if the resistors do not all have the same value, so long as the numerator in the above equation is zero, i.e., if 3 1 4 2R R R R . Or, expressed as ratios, the bridge is balanced if 1 4 2 3 R R R R  .  In practice, the bridge will not be balanced automatically, since “identical” resistors are not actually identical, with resistance varying by up to several percent. Thus, a potentiometer (variable resistor) is sometimes applied in place of one of the resistors in the bridge so that minor adjustments can be made in order to balance the bridge. o An arrow through the resistor indicates that its resistance can vary, as sketched to the right. o In this circuit, resistor R2 was arbitrarily chosen to be replaced by a potentiometer, but any of the four resistors could have been used instead. Quarter bridge circuit  To measure strain, one of the resistors, in this case R3, is replaced by the strain gage, as sketched to the right. (Note that one of the other resistors may still be a potentiometer rather than a fixed resistor, but that will not be indicated on the circuit diagrams to follow.)  Again, an arrow through the resistor indicates that its resistance can vary  this time because R3 is an active strain gage, not a potentiometer.  With only one out of the four available resistors substituted by a strain gage, as in the above schematic, the circuit is called a quarter bridge circuit.  The output voltage Vo is calculated from Ohm’s law, as previously,    3 1 4 2 o 2 3 1 4 s R R R R V V R R R R     .  Let R1 = R2 = R4 = 120 , and let the initial resistance of the strain gage (with no load) be R3,initial = 120 .  The bridge is therefore initially balanced when R3 = R3,initial, since R3,initialR1 – R4R2 = 0, and Vo is thus zero. Vs = supply voltage R1 R2 R4 R3 Vo +  +  Pot Vs = supply voltage R1 R2 R4 R3 Vo + +  R3 = strain gage Vs = supply voltage R1 R2 R4 R3 Vo + +  Vo – Vo +
  • 4. Stress, Strain, and Strain Gages, Page 4 Unbalanced quarter bridge circuit - to measure strain  In normal operation, the Wheatstone bridge is initially balanced as above. Now suppose strain is applied to the strain gage, such that its resistance changes by some small amount R3. In other words, R3 changes from R3,initial to R3,initial + R3.  Under these conditions the bridge is unbalanced, and the resulting output voltage Vo is not zero, but can be calculated as      3,initial 3 1 4 2 o 2 3,initial 3 1 4 s R R R R R V V R R R R R         .  We simplify the numerator by applying the initial balance equation, R3,initialR1 – R4R2 = 0, yielding    3 1 o 2 3,initial 3 1 4 s R R V V R R R R R        . [This equation is exact only if the bridge is initially balanced.]  We simplify the denominator by recognizing, as pointed out previously, that the change in resistance of a strain gage is very small; in other words, R3/R3,initial << 1. This yields    3 1 o 2 3,initial 1 4 s R R V V R R R R      .  We apply the relationship derived earlier for change in resistance of a strain gage as a function of axial strain, resistance, and strain gage factor, namely, 3 3,initial aR R S  . After some algebra,   2 2 3,initialo 2 3,initial 1 a s R RV V S R R    .  Furthermore, since R2 = R3,initial (e.g., both are 120 ), this reduces to o 1 4a s V V S   or o 4 a s S V V   .  The significance of this result is this: For constant supply voltage Vs and constant strain gage factor S, axial strain at the location of the strain gage is a linear function of the output voltage from the Wheatstone bridge circuit.  Even more significantly: For known values of S and Vs, the actual value of the strain can be calculated from the above equation after measurement of output voltage Vo.  Example: Given: A standard strain gage is used in a quarter bridge circuit to measure the strain of a beam in tension. The strain gage factor is S = 2.0, and the supply voltage to the Wheatstone bridge is Vs = 5.00 V. The bridge is balanced when no load is applied. Assume all resistors are equal when the strain gage circuit is initially balanced with no load. For a certain non-zero load, the measured output voltage is Vo = 1.13 mV. To do: Calculate the axial strain on the beam. Solution: o We apply the above equation for axial strain for a quarter bridge circuit, yielding o 1 1.13 mV 1 1 V 4 4 5.00 V 2.0 1000 mV a s V V S          = 0.000452. o Since strain is such a small number, it is common to report strain in units of microstrain (strain), defined as the strain times 106 . Note that strain is dimensionless, so microstrain is a dimensionless unit. o The unit conversion between strain and microstrain, expressed as a dimensionless ratio, is (106 microstrain/strain). Thus, 6 10 strain 0.000452 strain a          = 452 strain. o Finally, keeping to two significant digits (since S is given to only two digits), 450 straina  . Discussion: It is also correct to give the final answer as 0.00045a  . Half bridge circuit  Suppose we mount two active strain gages on the beam, one at the front and one at the back as sketched to the right.  Also suppose that both strain gages are put into the Wheatstone bridge circuit, as shown in the circuit diagram below, noting that resistors R1 and R3 have been Front strain gage Beam Rear strain gage F
  • 5. Stress, Strain, and Strain Gages, Page 5 replaced by the two strain gages.  Since half of the four available resistors in the bridge are strain gages, this is called a half bridge circuit.  After some algebra, assuming that both strain gage resistances change identically as the strain is applied, it can be shown that   2 2 3,initialo 2 3,initial 1 2 a s R RV V S R R    .  Furthermore, since R2 = R3,initial = 120 , the above equation reduces to o 1 2a s V V S   or o 2 a s S V V   .  Compared to the quarter bridge circuit, the half bridge circuit yields twice the output voltage for a given strain. We say that the sensitivity of the circuit has improved by a factor of two.  You might ask why R1 (rather than R2 or R4) was chosen as the resistor to replace with the second strain gage. It turns out that R1 is used for the second strain gage if its strain is of the same sign as that of R3.  To prove the above statement, suppose all four resistors are strain gages with initial values R1,initial, R2,initial, etc. The corresponding changes in resistance due to applied strain are R1, R2, etc. It can be shown (via application of Ohm’s law, and neglecting higher-order terms as previously) that the output voltage varies as   2,initial 3,initialo 31 2 4 2 1,initial 2,initial 3,initial 4,initial2,initial 3,initials R RV RR R R V R R R RR R              . [This equation is approximate – assumes initially balanced bridge and small changes in resistance.]  As can be seen, the terms with R1 and R3 are of positive sign, and therefore contribute to a positive output voltage when the applied strain is positive (strain gage in tension).  However, the terms with R2 and R4 are of negative sign, and therefore contribute to a negative output voltage when the applied strain is positive (strain gage in tension).  In the above beam example, in which both strain gages measure the same strain, it is appropriate to choose R1 for the second strain gage. If R2 or R4 had been chosen instead, the output voltage would not change at all as strain is increased, because of the signs in the above equation. (The change in resistance of the two strain gages would cancel each other out!) Example  a cantilever beam experiment  As an example, consider a simple lab experiment. A cantilevered beam is clamped to the lab bench, and a weight is applied at the end of the beam as sketched to the right. A strain gage is attached on the top surface of the beam, and another is attached at the bottom surface, as shown.  As the beam is strained due to the applied force, the top strain gage is stretched (positive axial strain), but the bottom strain gage is compressed (negative axial strain).  If the beam is symmetric in cross section, and if the two strain gages are identical, the two strain gages have approximately the same magnitude of change in resistance, but opposite signs, i.e., Rbottom = Rtop.  In this case, if R1 and R3 were chosen for the two strain gages in the bridge circuit, the Wheatstone bridge would remain balanced for any applied load, since R1 and R3 would cancel each other out.  In this example, the half bridge circuit should be constructed with pairs of resistors that have opposite signs in the above general equation – the choices are R1 and R2, R1 and R4, R2 and R3, or R3 and R4 as the two resistors to be substituted by the strain gages.  An example circuit for this simple experiment uses R3 for the top strain gage and R4 for the bottom strain gage, with the Wheatstone bridge circuit wired as sketched to the right. Bench Clamp Strain gages (on top and bottom) F Cantilevered beam Vs = supply voltage R1 R2 Vo + +  R3 = top strain gage R4 = bottom strain gage Vs = supply voltage R1 R2 R4 R3 Vo + +  R1 = strain gage R3 = strain gage
  • 6. Stress, Strain, and Strain Gages, Page 6  Circuit analysis for this case yields o 1 2a s V V S   or o 2 a s S V V   .  Compared to the quarter bridge circuit, the voltage output of this half bridge circuit (with two active strain gages) is twice that of the quarter bridge circuit (with only one active strain gage), all else being equal.  For any system, sensitivity is defined as (change in output) / (change in input). In this case, the output is the voltage Vo, and the input is the axial strain being measured.  Thus, we conclude: The sensitivity of a half bridge Wheatstone bridge circuit is twice that of a quarter bridge Wheatstone bridge circuit. Full bridge circuit  If we substitute strain gages for all four resistors in a Wheatstone bridge, the result is called a full bridge circuit, as sketched to the right.  Warning: You need to be very careful with the signs when wiring a full bridge circuit!  If the wiring is done properly (e.g., R1 and R3 have positive strain, while R2 and R4 have negative strain), the sensitivity of the full bridge circuit is four times that of a quarter bridge circuit, o 1 a s V V S   or o a sV SV .  In general, we define n as the number of active gages in the Wheatstone bridge: o n = 1 for a quarter bridge o n = 2 for a half bridge o n = 4 for a full bridge  Then the strain can be generalized to o4 1 a s V n V S   or o 4 a s n V SV .  One cautionary note: In derivation of the above equation, it is assumed that positive strain gages (R1 and R3) are chosen for positive strain (tension), and negative strain gages (R2 and R4) are chosen for negative strain (compression). If instead we were to wire the circuit such that the positive gages are in compression and the negative gages are in tension, a negative sign would appear in the above equation.  On a final note, it is not always necessary to initially balance the bridge. In other words, suppose there is some initial non-zero value of bridge output voltage, namely Vo,reference  0. This voltage represents the reference output voltage at some initial conditions of the experiment, which may not necessarily even be zero strain.  We can still calculate the strain by using the output voltage difference rather than the output voltage itself,  o o,reference4 1 a s V V n V S    or o o,reference 4 a s n V V SV  .  In the lab, we use voltmeters with a “REL” button, which stands for “relative” voltage. [On some voltmeters, the REL button is indicated by triangular symbol “” instead.]  Under conditions of zero strain with a slightly unbalanced bridge, the reference output voltage is not zero (Vo,reference  0). However, pushing the REL button causes the voltmeter to read all subsequent voltages relative to Vo,reference. In other words, the voltmeter reads Vo – Vo,reference instead of Vo itself. We effectively “trick” the voltmeter into showing zero voltage for zero strain.  Warning: The REL button can be dangerous if you forget to turn it off, because all subsequent voltages are displayed relative to the voltage input at the time the REL button was pushed. Vs = supply voltage R1 R2 R4 R3 Vo + + 