DESIGN REFERENCE FOR
ELEVATOR INSTALLATIONS
NexWay
● Control, Door and Operation Systems
Selective collective (2BC)
The system consists of call buttons in the car, and a
riser of up and down destination floor buttons installed
at each elevator hall (single button at terminal floors),
which connect electrically with microprocessors
supervising floor selection and direction of travel. A car
will respond to those car and hall calls that comply with
its direction of service.
When there are no more calls registered for the car’s
direction of travel, the car’s service direction is
reversed.
∑AI-22 & ∑AI-2200C Group Control Systems
The systems, which employ an intelligent expert
system and fuzzy logic, are specially designed for
group control of 3 to 8 elevators (as described above).
Practical information required for group control is
stored in the system's memory as a “Knowledge
Database”. Drawing from this database, various traffic
conditions are monitored and analyzed applying
IF-THEN decision rules to maximize the effectiveness
of each elevator operation.
The systems perform assignments to the most-used
locations, and thereby provide superb efficiency and
service.
In addition to the above, ΣAI-2200C system performs
optimal car allocation using Dynamic Rule-set
Optimizer.
1 car
2 cars
3 cars
4 cars
5 cars
6 cars
7 cars
8 cars
Number of
elevators
in a bank
● (1C-2BC)
—
—
—
—
—
—
—
—
● (2C-2BC)
—
—
—
—
—
—
—
—
● (3C-ΣAI-22)
● (4C-ΣAI-22)
—
—
—
—
—
—
● (3C-ΣAI-2200C)
● (4C-ΣAI-2200C)
● (5C-ΣAI-2200C)
● (6C-ΣAI-2200C)
● (7C-ΣAI-2200C)
● (8C-ΣAI-2200C)
1-car selective
collective
(Standard)
2-car group
control system
(optional)
ΣAI-22 group
control system
(option)
ΣAI-2200C group
control system
(option)
VVVF control and
Data Network
System
with multiple
microprocessor
modules
(VFGH)
VVVF control with
microprocessor,
2-panel center
opening <CO>
(Standard),
2-panel side
opening <2S>
(option),
4-panel center
opening <2CO>
(option)
Control system Door system
Operation system
● Capacity and Speed *1
750
900
1050
1200
1350
1600
1800
2000
2250
2500
3000
10
12
14
16
18
21
24
26
30
33
40
●
●
●
●
●
●
●
●
2.0
●
●
●
●
●
●
●
●
2.5 3.0 3.5 4.0
●
●
●
●
●
●
●
●
5.0
●
●
●
●
●
●
●
●
6.0 7.0 8.0 9.0 10.0
EN81-1
Rated speed (m/sec)Rated
capacity
(kg)
Number
of
persons
● Specifications *1
Rated speed (m/sec)
Maximum number of stops
750kg
900kg
1050kg
1200kg
1350kg
1600kg
1800kg
2000kg
150
150
200
150
250
250
250
Maximum travel (m) *2
Minimum floor height (mm) 2500 *3
2.0 2.5 3.0 3.5 4.0
Please consult our local agents.
Please consult our local agents.
Please consult our local agents.
Please consult our local agents.
Please consult our local agents.
5.0 6.0 7.0 8.0 9.0 10.0
●: Applicable —: Not applicable
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
64
Notes:
*1: Please consult our local agents if the maximum travel exceeds the values specified in the above table.
*2: For the rated capacity 2250kg to 3000kg, please consult our local agents for maximum travel.
*3: For some elevator specifications, the floor height (distance between floors) must be a minimum of 2500mm.
Please consult our local agents if the floor height is less than “Entrance height HH + 700mm”.
Notes:
*1: The symbol shown in the table indicates that a technical inquiry is required.
The symbol ● shown in the table indicates that a technical inquiry is required depending on conditions.
*2: Refer to page 5 to 12 for the hoistway and machine room layout plans for the models with specifications marked in gray ( ).
For the layouts for models with other specifications, please consult our local agents.
BASIC SPECIFICATIONS OF THE NexWay
1 2
● Elevator installations should be properly
planned according to such factors as the
size and nature or kind of the building,
the traffic flow and peak traffic demand
or conditions, the location of public
transportation facilities and stores.
● Dispersing elevators in different areas of
a building adversely affects their
passenger-carrying efficiency. Therefore,
elevators should, as far as possible, be
concentrated in the center of the
building.
● When two groups of elevators face each
other, ample space should be left
between the groups.
● The number of elevators in each group
should be decided on the basis of the
physical arrangement of the elevators
and the floors served.
● As much as possible, all the floors
served by one group of elevators should
be functionally and structurally similar.
Dissimilarity among the floors served will
result in a drop in service level.
● In residential buildings, hotels, and the
like, it is not desirable for the elevator
hall to be located farther than 50 meters
from any apartment or room.
● In steel-reinforced concrete
buildings, design the hoistways so
that concrete walls are at least
120mm thick.
● Hoistways must be no more than
30mm out of plumb.
● No wiring or distribution panels
should be built into or mounted on
hoistway walls.
● It is forbidden under most building
codes to install any conduit work or
piping in hoistways except as
required for the elevator itself.
● Pit-depth and overhead-height
dimensions must always be at least
the minimum shown in the drawings.
● If it proves necessary to make use of
space below the pit, contact our
local subcontractor.
● When the building is to be of steel
construction, our local
subcontractor should be brought
into the discussion at the earliest
possible moment.
● Provide the recommended width
and height to assure that there will
be sufficient room for inspection and
maintenance.
● Since the elevator drive equipment
generates considerable heat,
sufficient ventilation and or air-
conditioning capacity must be
provided to assure that the
machine-room temperature does
not exceed 40°C.
Refer to elevator site requirements
at page 18 for details.
● When occupied areas of the building
are in close proximity to the
machine room, such as in the case
of elevators for the low and middle
floors of a high-rise building, it may
be desirable to provide additional
soundproofing or intervening walls.
● Some Examples of Bank Arrangements
Desirable Plans
● Notes on Installation Planning
Elevator Arrangement
Points Relating to the
Hoistway
Points Relating to the
Machine Room
● Selecting the Operation System
Large-scale office building
Recommended elevator speedMax. no. of floors served
60 floors
55 floors
50 floors
45 floors
40 floors
35 floors
30 floors
25 floors
20 floors
15 floors
10 floors
5 floors
Scale of building
Number of elevators
Medium-scale office building
Operation system 1 2 3 4 5 6 7 8
1-car selective collective (2BC)
2-car group control system (2BC)
∑AI-22 group control system
∑AI-2200C group control system
Elevator traffic reaches a peak when people employed
in the building arrive for work in the morning, when
they break for lunch at midday, and when they leave
for home in the evening. Obviously, the elevators must
be capable of handling the increased traffic during
these peaks. And during actual business hours, the
elevators must be able to respond promptly to serve
the people who are on the move inside the building as
well as those who arrive at or leave the building. So
that the elevators best suited to the conditions and
environment at hand can be selected, Mitsubishi
Electric applies computer simulation, traffic
computation, and other techniques based on its wealth
of experience in this field to offer a wide range of
elevator consulting services. Given below are reference
data useful for general planning.
Selecting the Elevator Speed
The maximum number of floors served in a building
serves as the criterion for selecting the speed at which
the elevators should travel. To select elevators using
the chart below, if the building has 23 floors, select
elevators with a speed of 3.5m/sec or 4.0m/sec.
Note: The following chart shows the recommended elevator
speed per maximum number of service floors. The best
suited speed varies depending on the following factors:
*Building usage;
*Single-tenant building or multi-tenant building;
*Floor heights;
*Population in the building;
*Number of elevators in the group; or
*Capacity of the elevator.
Please consult our local agents for details.
Applicable system Recommended system
Undesirable Plans
1.0m/sec
1.5
m/sec
1.75
m/sec
2.0
m/sec
2.5m/sec
3.0m/sec
3.5m/sec
4.0m/sec
5.0m/sec
6.0m/sec
7.0m/sec
8.0m/sec
9.0m/sec
10.0m/sec
STANDARD INSTALLATIONREFERENCE DATA FOR ELEVATOR PLANNING
3 4
Note: The dimensions OH are calculated when the car frame height
(HB) is 3450mm.
−
−
−
−
−
−
750 900 1050 1350 1600 1800 2000
2080
2800
2080
2840
3050
3200
1200
3500
3600
3150
3300
3330
Rated capacity (kg)
2.0
2.5
3.0
Rated
speed
(m/sec)
TR<
=100
100<TR<
=150
150<TR<
=200
200<TR<
=250
TR<
=100
100<TR<
=150
150<TR<
=200
200<TR<
=250
TR<
=100
100<TR<
=150
150<TR<
=200
200<TR<
=250
Travel
TR
(m)
★ All the above dimensions are calculated based on EN81-1 (1998).
★ The dimensions shown are minimum requirements, particularly in the figures of TC, OH and PD.
Necessary tolerance should be separately considered for the building construction errors.
★ The dimensions TC, OH, PD and reaction load are calculated according to car and hoistway dimensions on the above table and conditions.
Note:
*1: The dimensions PD, OH and BH are calculated when the counterweight without safety gear is located in back of the car.
P10
P12
P14
P16
P18
P21
P24
P26
P12
P14
P16
P18
P21
P24
P26
750
900
1050
1200
1350
1600
1800
2000
900
1050
1200
1350
1600
1800
2000
10
12
14
16
18
21
24
26
12
14
16
18
21
24
26
800
900
900
1000
1100
1100
1100
1100
900
900
1000
1100
1100
1100
1100
1400×1300
1600×1300
1600×1500
1800×1500
2000×1500
2000×1700
2100×1750
2100×1950
1600×1300
1600×1500
1800×1500
2000×1500
2000×1700
2100×1750
2100×1950
Car
internal
dimensions
(mm)
1-unit
installation
1900×2050
2100×2050
2100×2250
2300×2250
2500×2250
2500×2450
2600×2550
2600×2750
2100×2050
2100×2300
2300×2300
2500×2300
2500×2500
2600×2550
2600×2750
2-unit
installation
3900×2050
4300×2050
4300×2250
4700×2250
5100×2250
5100×2450
5300×2550
5300×2750
4300×2050
4300×2300
4700×2300
5100×2300
5100×2500
5300×2550
5300×2750
2-unit
installation
4500×3455
4700×3455
4700×3655
4900×3655
5100×3655
5100×3855
5400×3955
5400×4105
4700×3455
4700×3655
4900×3655
5100×3655
5100×3855
5400×3955
5400×4105
Width×Depth
AA×BB
Width×Depth
AH×BH
Width×Depth
AH×BH
Width×Depth
AM×BM
2.0
2.5
3.0
Rated
speed
(m/sec)
Code
number
Rated
capacity
(kg)
Number
of
persons
Entrance
width
JJ (mm)
● Dimension table of car, hoistway and machine room
● Overhead-height (OH) *1
● Pit-depth (PD) *1
2.0
2.5
3.0
TR<
=100
1760
1840
2190
100<TR<
=250
1910
1990
2340
Travel (TR) (m)
Rated speed
(m/sec)
● Top clearance (TC)
Layout example of in-line arrangement
(Unit: mm)
(Unit: mm)
(Unit: mm)
2.0
2.5
3.0
Regulation
EN81-1
2500
Rated speed
(m/sec)
● Machine-room height (HM) (Unit: mm)
In-line arrangement
Internal
dimensions
of machine
room (mm)
Internal dimensions
of hoistway (mm) *1
Rated capacity (kg)Rated
speed
(m/sec)
2.0
2.5
3.0
R1
R2
P1
P2
R1
R2
P1
P2
900
94
63
137
124
106
70
149
138
750
94
63
129
121
−
1050
123
82
178
164
157
105
205
200
1200
112
74
159
142
158
106
191
185
1350
149
100
191
182
160
106
196
182
1600
156
104
195
181
161
107
214
189
1800
174
116
227
196
191
127
245
215
2000
200
134
246
227
193
129
245
215
● Reaction loads in machine room and pit
Hoistway
(Unit: kN)
Elevation
Machine room
100-125
AH
AA
JJ
BB
BH
AM (min)
R1
R2
Intercom (option)
Ventilationwindow
(byowner)
Attachment
panel
Control
panel
Control
panel
BM(min)
Power receiving box
(by owner)
Power outlet
(by owner)
Lighting outlet
(by owner)
Width:1000
Height:2000
Accessdoor:(byowner)
Ventilator
(byowner)
Entranceheight:
HH=2100
Hoisting hook or trolley beam (by owner)
HM(min.)
OH(min.)
TCHB=3450
HL
PD(min.)Travel(TR)
Totalheight
P1 P2
Cinder-concrete finish
(by owner)
Highest
floor
Lowest
floor
33503330
2650
−
−
−
−
−
750 900 1050 1350 1600 1800 2000
5210
5360
5290
5440
5360
5440
5360
5440
1200
Rated capacity (kg)
2.0
2.5
3.0
Rated
speed
(m/sec)
TR<
=100
100<TR<
=150
150<TR<
=200
200<TR<
=250
TR<
=100
100<TR<
=150
150<TR<
=200
200<TR<
=250
TR<
=100
100<TR<
=150
150<TR<
=250
Travel
TR
(m)
5640
5790
5790
−
−
RATED SPEED OF 2.0~3.0 m/sec
5 6
Note: The dimensions OH are calculated when the car frame
height (HB) is 3450mm.
750 900 1050
3020
3370
16001200
−
−
−
Rated capacity (kg)
3.5
4.0
Rated
speed
(m/sec)
TR<
=100
100<TR<<
=150
150<TR<<
=200
200<TR<<
=250
TR<<
=200
200<TR<<
=250
Travel
TR
(m)
★ All the above dimensions are calculated based on EN81-1 (1998).
★ The dimensions shown are minimum requirements, particularly in the figures of TC, OH and PD.
Necessary tolerance should be separately considered for the building construction errors.
★ The dimensions TC, OH, PD and reaction load are calculated according to car and hoistway dimensions on the above table and conditions.
Notes:
*1: The dimensions PD, OH and BH are calculated when the counterweight without safety gear is located in back of the car.
*2: Traction machine for the rated capacity 1600kg differs depending on the car weight.
*3: AM×BM is 5300×3855 only when the rated speed is 4.0m/sec and traction machine type is PML-F50.
● Dimension table of car, hoistway and machine room
● Overhead-height (OH) *1● Pit-depth (PD) *1
3.5
4.0
TR<
=100
2520
3070
2670
100<TR<
=150 150<TR<
=250
Travel (TR) (m)
Rated speed
(m/sec)
● Top clearance (TC)
(Unit: mm)(Unit: mm)
(Unit: mm)
3.5
4.0
Regulation
EN81-1
2500
Rated speed
(m/sec)
● Machine-room height (HM) (Unit: mm)
4.0
3.5
● Reaction loads in machine room and pit (Unit: kN)
Rated capacity (kg)
Rated
speed
(m/sec)
R1
R2
P1
P2
R1
R2
P1
P2
900
106
70
149
138
750
−
−
−
1050
157
105
205
200
158
105
204
199
1200
158
106
196
185
159
106
194
185
1350
160
106
196
182
159
106
194
182
161
107
214
189
162
108
214
190
188
125
241
215
1800
191
127
245
215
191
127
245
215
2000
193
129
245
215
193
129
249
215
750 900 1050
5970
6120
1600 1800 20001200
−
−
6120
6520
−
−
Rated capacity (kg)
3.5
4.0
Rated
speed
(m/sec)
TR<
=100
100<TR<
=150
150<TR<
=250
TR<
=250
Travel
TR
(m)
Hoistway
Elevator lobby
Machine room
Lobbywidth:
3500-4500
100-125
BB
BHBH
JJ
AAAH
Ventilationwindow
(byowner)
Ventilator
(by owner)R1
R2
Lighting outlet
(by owner)
Power receiving box
(by owner)
Power outlet
(by owner)
AM (min)
Intercom
(option)
BM(min)=lobbywidth+2BH
(byowner)Width:1000
Height:2000
Accessdoor:
Attach-
ment
panel
Attach-
ment
panel
Attachment
panel
Attachment
panel
Control
panel
Control
panel
Control
panel
Control
panel
Control
panel
Control
panel
Group
control
panel
Entranceheight:
HH=2100
P2 P2P1 P1
Hoisting hook or trolley beam (by owner)
HM(min.)
OH(min.)
TC
HB=
3450
PD(min.)Travel(TR)
Totalheight
HL
Cinder-concrete finish
(by owner)
Highest
floor
Lowest
floor
3660
3760
3920
4020
1800 2000
Layout example of facing arrangement
1600 *2
PM040MR PML-F50
P12
P14
P16
P18
P21
P24
P26
900
1050
1200
1350
1600
1800
2000
12
14
16
18
21
24
26
900
900
1000
1100
1100
1100
1100
1600×1300
1600× 1500
1800× 1500
2000× 1500
2000× 1700
2100× 1750
2100×1950
Car
internal
dimensions
(mm)
2-unit
installation
4400× 2100
4400× 2300
4800× 2300
5200× 2300
5200× 2500
5400× 2550
5400× 2750
2-unit
installation
4750× 3455
4750× 3655
4950×3655
5200×3655
5200×3855 *3
5400×3955
5400×4105
Width×Depth
AA×BB
Width×Depth
AH×BH
Width×Depth
AM×BM
3.5
4.0
3.5
Rated
speed
(m/sec)
Code
number
Rated
capacity
(kg)
Number
of
persons
Entrance
width
JJ (mm)
In-line arrangement
Internal
dimensions of
machine room (mm)
Internal
dimensions of
hoistway (mm) *1
1350 1350
Elevation
RATED SPEED OF 3.5, 4.0 m/sec
7 8
1200 1350 1600 1800 2000
Rated capacity (kg)
5.0
Rated
speed
(m/sec)
TR<
=150
150<TR<
=200
200<TR<
=250
4050
4350
4450
Travel
TR
(m)
★ All the above dimensions are calculated based on EN81-1 (1998).
★ The dimensions shown are minimum requirements, particularly in the figures of TC, OH and PD.
Necessary tolerance should be separately considered for the building construction errors.
★ TC, OH, PD and reaction load are calculated according to car and hoistway dimensions on the above table.
(When the counterweight is back drop.)
★ The shaft independently housing a single car is not recommended because noise increases.
Please consult our local agents if the shaft of that kind is required.
Note:
*1: The dimensions BH are calculated when the counterweight is equipped without safety gear.
● Dimension table of car, hoistway and machine room
● Overhead-height (OH) dimensions● Pit-depth (PD) dimensions
5.0
TR<
=150
3200
150<TR<
=250
3600
Travel (TR) (m)
Rated speed
(m/sec)
● Top clearance (TC) dimensions
(Unit: mm) (Unit: mm)
(Unit: mm)
● Machine-room height (HM) (Unit: mm)
● Reaction loads in machine room and pit (Unit: kN)
Hoistway
Elevator lobby
Machine room
Lobbywidth:
3500-4500
100-125
BB
BHBH
Ventilationwindow
(byowner)
R1
R2
Lighting outlet
(by owner)
Power receiving box
(by owner)
AM (min)
Width:1600or1900
Height:2000
Accessdoor
(byowner):
JJ
AAAH
Power outlet
(by owner)
BM(min)=lobbywidth+2BH
1200 1350 1600 1800 2000
Rated capacity (kg)
5.0
Rated
speed
(m/sec)
TR<
=150
150<TR<
=250
6650
7050
Travel
TR
(m)
Entranceheight:
HH=2100
Travel(TR)
Totalheight
P2 P2P1 P1
HM(min.)
OH(min.)
TC
PD(min.)
HL
Hoisting hook or trolley beam (by owner)
Cinder-concrete finish
(by owner)
Highest
floor
Lowest
floor
Reactor
panel
Control
panel
Reactor
panel
Control
panel
Reactor
panel
Control
panel
Reactor
panel
Control
panel
Reactor
panel
Control
panel
Reactor
panel
Control
panel
Distribution
panel
Group control panel
Intercom (option)
Distribution
panel
Ventilator
(by owner)
1200 1350
2300
1600
2300
1800 2000
Rated capacity (kg)
5.0
Rated
speed
(m/sec)
TR<
=150
150<TR<
=250 2800
Travel (TR)
(m)
Layout example of facing arrangement
Note: The dimensions OH are calculated when the car frame
height (HB) is 3450mm.
HB=
3450
1200
165
110
215
205
1350
175
120
215
210
1600
185
125
225
205
1800
195
130
240
220
2000
195
130
240
220
Rated capacity (kg)
5.0
Rated speed
(m/sec)
R1
R2
P1
P2
● Dimension table of car, hoistway and machine room
P16
P18
P21
P24
P26
1200
1350
1600
1800
2000
16
18
21
24
26
1000
1100
1100
1100
1100
1800× 1450
2000× 1450
2000× 1700
2100× 1750
2100×1950
Car
internal
dimensions
(mm)
2-unit
installation
5100× 2300
5500× 2300
5500× 2550
5700× 2650
5700× 2850
2-unit
installation
5300×4000
5500×4000
5500×4250
5700×4300
5700×4450
Width×Depth
AA×BB
Width×Depth
AH×BH
Width×Depth
AM×BM
5.0
Rated
speed
(m/sec)
Code
number
Rated
capacity
(kg)
Number
of
persons
Entrance
width
JJ (mm)
In-line arrangement
Internal
dimensions of
machine room (mm)
Internal
dimensions of
hoistway (mm) *1
Elevation
RATED SPEED OF 5.0 m/sec
9 10
★ All the above dimensions are calculated based on EN81-1 (1998).
★ The dimensions shown are minimum requirements, particularly in the figures of TC, OH and PD.
Necessary tolerance should be separately considered for the building construction errors.
★ TC, OH, PD and reaction load are calculated according to car and hoistway dimensions on the above table.
(When the counterweight is back drop.)
★ The shaft independently housing a single car is not recommended because noise increases.
Please consult our local agents if the shaft of that kind is required.
Note:
*1: The dimensions BH are calculated when the counterweight is equipped without safety gear.
Hoistway
Elevator lobby
Machine room
Lobbywidth:
3500-4500
100-125
Ventilationwindow
(byowner)
R2
Width:1600or1900
Height:2000
Accessdoor
(byowner):
BM(min)=lobbywidth+2BH
Entranceheight:
HH=2100
P2 P2P1 P1
HM(min.)
OH(min.)
TC
PD(min.)
HL
BB
BHBH
JJ
AAAH
Lighting outlet
(by owner)
Power receiving box
(by owner)
Power outlet
(by owner)
Hoisting hook or trolley beam (by owner)
Highest
floor
Lowest
floor
Cinder-concrete finish
(by owner)
Travel(TR)
Totalheight
Reactor
panel
Control
panel
Reactor
panel
Control
panel
Reactor
panel
Control
panel
Reactor
panel
Control
panel
Reactor
panel
Control
panel
Reactor
panel
Control
panel
Distribution
panel
Group control panel
Intercom (option)
Distribution
panel
R1
AM (min)
Ventilator
(by owner)
6.0
TR<
=150
3200
150<TR<
=250
3600
Travel (TR) (m)
Rated speed
(m/sec)
● Top clearance (TC) dimensions (Unit: mm)
● Machine-room height (HM) (Unit: mm)
1200 1350
2300
1600
2300
1800 2000
Rated capacity (kg)
6.0
Rated
speed
(m/sec)
TR<
=150
150<TR<
=250 2800
Travel (TR)
(m)
1200 1350 1600 1800 2000
Rated capacity (kg)
6.0
Rated
speed
(m/sec)
TR<
=150
150<TR<
=200
200<TR<
=250
4050
4350
4450
Travel
TR
(m)
● Pit-depth (PD) dimensions (Unit: mm)● Reaction loads in machine room and pit (Unit: kN)
1200
170
115
215
210
1350
170
115
215
205
1600
185
125
230
215
1800
195
130
240
220
2000
195
130
240
220
Rated capacity (kg)
6.0
Rated speed
(m/sec)
R1
R2
P1
P2
Layout example of facing arrangement
● Overhead-height (OH) dimensions (Unit: mm)
1200 1350 1600 1800 2000
Rated capacity (kg)
6.0
Rated
speed
(m/sec)
TR<
=150
150<TR<
=250
6650
7050
Travel
TR
(m)
Note: The dimensions OH are calculated when the car frame
height (HB) is 3450mm.
HB=
3450
● Dimension table of car, hoistway and machine room● Dimension table of car, hoistway and machine room
P16
P18
P21
P24
P26
1200
1350
1600
1800
2000
16
18
21
24
26
1000
1100
1100
1100
1100
1800× 1450
2000× 1450
2000× 1700
2100× 1750
2100×1950
Car
internal
dimensions
(mm)
2-unit
installation
5100× 2300
5500× 2300
5500× 2600
5700× 2650
5700× 2850
2-unit
installation
5250×4000
5550×4000
5550×4250
5700×4300
5700×4450
Width×Depth
AA×BB
Width×Depth
AH×BH
Width×Depth
AM×BM
6.0
Rated
speed
(m/sec)
Code
number
Rated
capacity
(kg)
Number
of
persons
Entrance
width
JJ (mm)
In-line arrangement
Internal
dimensions of
machine room (mm)
Internal
dimensions of
hoistway (mm) *1
Elevation
RATED SPEED OF 6.0 m/sec
11 12
Type E-102 (standard) Type E-302, E-312 (option)
Building structure
(by owner)
Wall and floor finishing
(by owner)
Note: 1. Triangular key-hole is required under EN81-1.
2. Details in sections A-A and B-B are not for
BS-476 fire rated doors.
Door plan (section B-B)
Hoistway entrance
Door elevation
(section A-A)
Building structure
(by owner)
Wall and floor finishing
(by owner)
Note: 1. Triangular key-hole is required under EN81-1.
2. Details in sections A-A and B-B are not for
BS-476 fire rated doors.
ENTRANCE LAYOUT DRAWINGS
13 14
● Power Feeder Data *1
FLU: current during upward operation with full load at power supply voltage of 400V.
FLAcc: current while accelerating with full load at power supply voltage of 400V.
Notes:
*1: The values in the table above are for the case where power supply voltage is 400V. If the power supply voltage is within the range of
380 to 440V (except for 400V), calculate values by referring to page 16. If the power supply voltage is not within the range of 380 to
440V, please consult our local agents.
*2: If power supply voltage (E) is a value other than 400V, FLU current and FLAcc current are obtained via the following formula.
(FLU/FLAcc current (A) at E (V)) = (Current at 400V) × (400/E (V))
2.0
2.5
3.0
3.5
4.0
5.0
6.0
750
900
1050
1200
1350
1600
1800
2000
750
900
1050
1200
1350
1600
1800
2000
750
900
1050
1200
1350
1600
1800
2000
750
900
1050
1200
1350
1600
1800
2000
750
900
1050
1200
1350
1600
1800
2000
1200
1350
1600
1800
2000
1200
1350
1600
1800
2000
15
15
15
20
20
20
23
28
18
18
18
25
25
25
28
35
22
22
22
30
30
30
34
42
25
25
25
35
35
35
39
49
29
29
29
40
40
40
45
56
42
42
50
53
58
56
56
56
63
70
27
31
33
37
41
47
57
59
31
36
39
44
48
56
67
70
34
39
45
50
56
65
76
81
40
44
51
57
63
74
92
94
44
49
57
64
71
83
102
104
80
88
103
114
126
92
102
120
133
147
52
56
61
67
72
82
98
107
64
69
75
82
88
100
121
134
74
81
90
98
105
119
143
163
97
99
113
124
131
144
174
197
110
112
123
135
143
165
196
231
196
211
238
253
274
237
252
284
304
328
16
18
19
21
23
26
31
33
18
20
21
23
25
29
34
37
19
21
23
25
28
32
40
42
21
23
27
30
33
37
46
47
23
26
30
33
36
41
49
51
41
44
50
57
62
46
50
59
65
72
75
75
75
75
75
75
100
100
75
75
75
75
75
100
100
100
75
75
75
100
100
100
125
125
75
75
100
100
100
125
125
150
75
100
100
125
125
150
150
150
125
125
150
175
200
150
150
175
200
225
2330
2800
3260
3730
4190
4970
5600
6210
2910
3490
4070
4660
5240
6210
7000
7800
3490
4190
4890
5590
6280
7450
8400
9400
4070
4890
5700
6520
7330
8690
9800
10860
4660
5590
6520
7450
8380
9930
11200
12410
9400
10500
12500
14000
15600
11200
12600
14900
16800
18700
Speed
(m/sec)
Rated load
(kg)
Traction motor
(kW)
Capacity of
power supply
(kVA)
NF in M/R
at 400V system
(A)
Heat
emission
(W)
Current at 400V *2
FLU (A) FLAcc (A)
The feeder must be able to withstand continuous flow of the following current at an ambient temperature of 40°C.
1.25 × FLU (A)……FLU <= 50 (A)
1.10 × FLU (A)……FLU > 50 (A)
(FLU (A): current during upward operation with full load at power supply voltage of 400V.)
The wire length for the feeder size must be calculated via the following formula.
Wire length (m) <= Coefficient* × E (V)/FLAcc (A)
(E: power supply voltage (V))
(FLAcc (A): current while accelerating with full load at power supply voltage of 400V)
*Refer to the table 1 for coefficients.
When power is supplied to multiple elevators in a group through a common feeder, the capacity of the power
supply transformer, the size of the feeder, and the current rating of the no-fuse (NF) breaker for one elevator are
each multiplied by the corresponding diversity factor at table 2.
Feeder Size Calculation
With express zoneWithout express zone
Diversity factor
For FLAcc
For FLU
No. of elevators
on common
feeder
Table 2
Feeder size
(mm2
)
Coefficient
Table 1
3.5
5.5
8
14
22
30
38
50
60
80
100
125
150
200
250
325
2
3
4
5
6
7
8
9
10
2.0
2.7
3.1
3.25
3.3
3.71
4.08
4.45
4.8
1.7
2.4
2.95
3.6
4.1
4.6
5.1
5.6
6.0
1.85
2.7
3.4
4.2
4.9
5.6
6.3
6.9
7.6
5.1
8.0
11.6
20.6
32.1
42.5
54.3
70.7
87.3
115
148
184
225
287
371
473
●
●
ELECTRICAL INSTALLATION
15 16
Traction-Machinery Power Supply
It is necessary to install power-supply equipment of
sufficient capacity to ensure the elevators accelerating
smoothly and landing accurately.
The power supply should be kept within a voltage-
fluctuation range of +5 ~ -10%, and a voltage-
imbalance factor of 5%.
When selecting protective breakers on the power-
supply side, be guided by voltage ratings of the
no-fuse breakers supplied with the elevators.
Ventilation Equipment
A machine-room ventilation device having a sufficient
capacity to keep the room temperature below 40°C is
required.
A ventilation window should also be installed at the
opposite side of ventilation fan.
Power Supply for Lighting
Lighting for the elevator cars and indicators, where
possible, should be supplied via a separate circuit that
will not be affected by power failures elsewhere.
Intercom (where necessary)
This is essential to establish the communication
between elevator passengers and outside in case of
emergency.
The master station transceiver is usually in a location
readily accessible to the supervisor, in the central
supervisor's room or elevator lobby. The wiring work
between the master station and the elevator machine
room is not included in the elevator contract.
To facilitate piping and wiring, it is desirable to decide
on the position of the master station at the earliest
stage of building design.
Lighting Equipment
The machine room should be fitted with good lighting
for maintenance work. The light switch should be
positioned close to the machine-room entrance.
Inspection Power Outlets
These should be installed in the machine room and pit
for use during inspection and maintenance.
● Electrical Equipment Required for Elevator Operation
Notes:
*1: The minimum size of ground wire is determined according to the ampere rating of the NF
breaker installed at the power source side.
*2: The ampere rating of the power-source NF breaker should be of one step larger than of
the receiving-box NF breaker installed in the elevator machine room.
NF breaker *2
Ground wire *1
The following items are excluded from Mitsubishi Electric’s elevator installation work, and are therefore the
responsibility of the building owner or general contractor:
• Construction of the elevator machine room with proper beams and slabs, equipped with a lock, complete with
illumination, ventilation and waterproofing.
• Access to the elevator machine room sufficient to allow passage of the control panel and traction machine.
• Architectural finishing of the machine room floor, and the walls and floors in the vicinity of the entrance hall after
installation has been completed.
• Construction of an illuminated, ventilated and waterproofed elevator hoistway.
• A ladder to the elevator pit.
• The provision of cutting the necessary openings and joists.
• Separate beams, when the hoistway dimensions markedly exceed the specifications, and intermediate beams
when two or more elevators are installed.
• All other work related to building construction.
• The machine room power-receiving panel and the electrical wiring for illumination, plus the electrical wiring from
the electrical room to the power-receiving panel.
• The laying of conduits and wiring between the elevator pit and the terminating point for the devices installed
outside the hoistway, such as the emergency bell, intercom, monitoring and security devices, etc.
• The power consumed in installation work and test operations.
• All the necessary building materials for grouting in of brackets, bolts, etc.
• The test provision and subsequent alteration as required, and eventual removal of the scaffolding as required by
the elevator contractor, and any other protection of the work as may be required during the process.
• The provision of a suitable, locked space for the storage of elevator equipment and tools during elevator
installation.
• The security system, such as a card reader, connected to Mitsubishi Electric's elevator controller, when supplied
by the building owner or general contractor.
* Work responsibilities in installation and construction shall be determined according to local laws. Please consult our local agents for details.
Work Not Included in Elevator Contract
• The temperature of the machine room and elevator hoistway shall be below 40˚C.
• The following conditions are required for maintaining elevator performance.
a. The relative humidity shall be below 90% on a monthly average and below 95% on a daily average.
b. The machine room and the elevator hoistway shall be finished with mortar or other materials so as to prevent
concrete dust.
c. Prevention shall be provided against icing and condensation occurring due to a rapid drop in the temperature in
the machine room and elevator hoistway.
• Voltage fluctuation shall be within a range of +5% to -10%.
Elevator Site Requirements
Please include the following information when ordering or requesting estimates:
• The desired number of units, speed and loading capacity.
• The number of stops or number of floors to be served.
• The total elevator travel and each floor-to-floor height.
• Operation system.
• Selected design and size of car.
• Entrance design.
• Signal equipment.
• A sketch of the part of the building where the elevators are to be installed.
• The voltage, number of phases, and frequency of the power source for the motor and lighting.
Ordering Information
Mitsubishi Elevator Inazawa Works has acquired ISO 9001
certification by the International Standards Organization
(ISO) based on a review of quality management.
The company has also acquired environmental management
system standard ISO 14001 certification.
NOTES ON INSTALLATION PLANNINGELECTRICAL INSTALLATION
17 18
C-CL1-4-C9343-A INA-1403 Printed in Japan (MDOC)
New publication effective Mar. 2014.
Specifications are subject to change without notice.
2014
Eco Changes is the Mitsubishi Electric Group’s environmental statement,
and expresses the Group’s stance on environmental management.
Through a wide range of businesses, we are helping contribute to the
realization of a sustainable society.
Visit our website at:
http://www.mitsubishielectric.com/elevator/

More Related Content

What's hot

Introduction to cnc machines (1)
Introduction to cnc machines (1)Introduction to cnc machines (1)
Introduction to cnc machines (1)someshking
 
Cnc pgrming seminar-
Cnc pgrming   seminar-Cnc pgrming   seminar-
Cnc pgrming seminar-abhipawar123
 
Cnc part programming 4 unit
Cnc part programming 4 unitCnc part programming 4 unit
Cnc part programming 4 unitpalanivendhan
 
12 cnc &amp; part programming
12 cnc &amp; part programming12 cnc &amp; part programming
12 cnc &amp; part programmingM Siva Kumar
 
CNC(COMPUTER NUMERICAL CONTROL MACHINE) By-Er. VED PRAKASH
CNC(COMPUTER NUMERICAL CONTROL MACHINE) By-Er. VED PRAKASHCNC(COMPUTER NUMERICAL CONTROL MACHINE) By-Er. VED PRAKASH
CNC(COMPUTER NUMERICAL CONTROL MACHINE) By-Er. VED PRAKASHVed Prakash
 
Iai erc3 cj0184 4-a-ust-2-0214
Iai erc3 cj0184 4-a-ust-2-0214Iai erc3 cj0184 4-a-ust-2-0214
Iai erc3 cj0184 4-a-ust-2-0214Electromate
 
Modern machine
Modern machineModern machine
Modern machineUbaid Shah
 

What's hot (9)

Introduction to cnc machines (1)
Introduction to cnc machines (1)Introduction to cnc machines (1)
Introduction to cnc machines (1)
 
Cnc pgrming seminar-
Cnc pgrming   seminar-Cnc pgrming   seminar-
Cnc pgrming seminar-
 
Cnc part programming 4 unit
Cnc part programming 4 unitCnc part programming 4 unit
Cnc part programming 4 unit
 
Ie450pp6
Ie450pp6Ie450pp6
Ie450pp6
 
12 cnc &amp; part programming
12 cnc &amp; part programming12 cnc &amp; part programming
12 cnc &amp; part programming
 
CNC(COMPUTER NUMERICAL CONTROL MACHINE) By-Er. VED PRAKASH
CNC(COMPUTER NUMERICAL CONTROL MACHINE) By-Er. VED PRAKASHCNC(COMPUTER NUMERICAL CONTROL MACHINE) By-Er. VED PRAKASH
CNC(COMPUTER NUMERICAL CONTROL MACHINE) By-Er. VED PRAKASH
 
Iai erc3 cj0184 4-a-ust-2-0214
Iai erc3 cj0184 4-a-ust-2-0214Iai erc3 cj0184 4-a-ust-2-0214
Iai erc3 cj0184 4-a-ust-2-0214
 
Modern machine
Modern machineModern machine
Modern machine
 
3 numerical control
3 numerical control3 numerical control
3 numerical control
 

Viewers also liked

виховний план 6 клас
виховний план 6 класвиховний план 6 клас
виховний план 6 класNataliakov
 
Fuel tank room_requirements
Fuel tank room_requirementsFuel tank room_requirements
Fuel tank room_requirementsstanjack99
 
Defensa del portafolio individual
Defensa del portafolio individualDefensa del portafolio individual
Defensa del portafolio individualsgc224
 
Clipsal control system 2008
Clipsal control system 2008Clipsal control system 2008
Clipsal control system 2008stanjack99
 
buongthangbotangap
buongthangbotangapbuongthangbotangap
buongthangbotangapstanjack99
 
EL CUADRO DE MANDO COMO HERRAMIENTA DE SOPORTE A LA COMUNICACIÓN Y GESTIÓN ES...
EL CUADRO DE MANDO COMO HERRAMIENTA DE SOPORTE A LA COMUNICACIÓN Y GESTIÓN ES...EL CUADRO DE MANDO COMO HERRAMIENTA DE SOPORTE A LA COMUNICACIÓN Y GESTIÓN ES...
EL CUADRO DE MANDO COMO HERRAMIENTA DE SOPORTE A LA COMUNICACIÓN Y GESTIÓN ES...Victor Manuel Agullo Boix
 
Lean start up bootcamp 5 three models to bring focus
Lean start up bootcamp 5   three models to bring focusLean start up bootcamp 5   three models to bring focus
Lean start up bootcamp 5 three models to bring focusJames Cracknell
 
"Defensa del portafolio individual"
"Defensa del portafolio individual""Defensa del portafolio individual"
"Defensa del portafolio individual"sgc224
 
Seguridad industrial
Seguridad industrialSeguridad industrial
Seguridad industrialyesidaldana
 
Taller Gratis Google My Business
Taller Gratis Google My BusinessTaller Gratis Google My Business
Taller Gratis Google My BusinessQuality Conta
 
Proyecto jin 15 16-17 taxco bueno
Proyecto jin 15 16-17 taxco buenoProyecto jin 15 16-17 taxco bueno
Proyecto jin 15 16-17 taxco buenocuartasala_2012
 
Renascimento cultural (cap.8)
Renascimento cultural (cap.8)Renascimento cultural (cap.8)
Renascimento cultural (cap.8)Wilton Moretto
 

Viewers also liked (20)

виховний план 6 клас
виховний план 6 класвиховний план 6 клас
виховний план 6 клас
 
2 katha bunglow brochure
2 katha bunglow brochure2 katha bunglow brochure
2 katha bunglow brochure
 
Higiene industrial
Higiene industrialHigiene industrial
Higiene industrial
 
Fuel tank room_requirements
Fuel tank room_requirementsFuel tank room_requirements
Fuel tank room_requirements
 
Defensa del portafolio individual
Defensa del portafolio individualDefensa del portafolio individual
Defensa del portafolio individual
 
Clipsal control system 2008
Clipsal control system 2008Clipsal control system 2008
Clipsal control system 2008
 
buongthangbotangap
buongthangbotangapbuongthangbotangap
buongthangbotangap
 
EL CUADRO DE MANDO COMO HERRAMIENTA DE SOPORTE A LA COMUNICACIÓN Y GESTIÓN ES...
EL CUADRO DE MANDO COMO HERRAMIENTA DE SOPORTE A LA COMUNICACIÓN Y GESTIÓN ES...EL CUADRO DE MANDO COMO HERRAMIENTA DE SOPORTE A LA COMUNICACIÓN Y GESTIÓN ES...
EL CUADRO DE MANDO COMO HERRAMIENTA DE SOPORTE A LA COMUNICACIÓN Y GESTIÓN ES...
 
Lean start up bootcamp 5 three models to bring focus
Lean start up bootcamp 5   three models to bring focusLean start up bootcamp 5   three models to bring focus
Lean start up bootcamp 5 three models to bring focus
 
EXPOSICION WEB 2.0
EXPOSICION WEB 2.0 EXPOSICION WEB 2.0
EXPOSICION WEB 2.0
 
"Defensa del portafolio individual"
"Defensa del portafolio individual""Defensa del portafolio individual"
"Defensa del portafolio individual"
 
Sayus
SayusSayus
Sayus
 
Agua
AguaAgua
Agua
 
Seguridad industrial
Seguridad industrialSeguridad industrial
Seguridad industrial
 
Taller Gratis Google My Business
Taller Gratis Google My BusinessTaller Gratis Google My Business
Taller Gratis Google My Business
 
Proyecto jin 15 16-17 taxco bueno
Proyecto jin 15 16-17 taxco buenoProyecto jin 15 16-17 taxco bueno
Proyecto jin 15 16-17 taxco bueno
 
Psycho
Psycho Psycho
Psycho
 
Psycho
Psycho Psycho
Psycho
 
Renascimento cultural (cap.8)
Renascimento cultural (cap.8)Renascimento cultural (cap.8)
Renascimento cultural (cap.8)
 
Proceso de traducción
Proceso de traducciónProceso de traducción
Proceso de traducción
 

Similar to Nex way design_ref

building service - lift and escalators
building service - lift and escalatorsbuilding service - lift and escalators
building service - lift and escalatorsrajitk97
 
Vertical transporation systems in building
Vertical transporation systems in buildingVertical transporation systems in building
Vertical transporation systems in buildingSelva Architect
 
STAIRS AND LIFTS IN ARCHIETCTURE
STAIRS AND LIFTS IN ARCHIETCTURESTAIRS AND LIFTS IN ARCHIETCTURE
STAIRS AND LIFTS IN ARCHIETCTURESYED PASHA
 
newelb_en5151615165156151561651_2203.pdf
newelb_en5151615165156151561651_2203.pdfnewelb_en5151615165156151561651_2203.pdf
newelb_en5151615165156151561651_2203.pdfAimanAlArab
 
lift and escalator.pdf
lift and escalator.pdflift and escalator.pdf
lift and escalator.pdfDeepika Verma
 
Express product catalog
Express product catalogExpress product catalog
Express product catalogMaxpromotion
 
Service core
Service coreService core
Service coreaduiti
 
Arrangement of Escalators and Elevators
Arrangement of Escalators and ElevatorsArrangement of Escalators and Elevators
Arrangement of Escalators and ElevatorsRohit Khurana
 
Catalogue Thang máy Mitsubishi_Series-NEXIEZ-MRL.pdf
Catalogue Thang máy Mitsubishi_Series-NEXIEZ-MRL.pdfCatalogue Thang máy Mitsubishi_Series-NEXIEZ-MRL.pdf
Catalogue Thang máy Mitsubishi_Series-NEXIEZ-MRL.pdfThang máy Vinalift
 
Irish Constuction Industry Magazine_Sept_2008_Cost Model_Lifts
Irish Constuction Industry Magazine_Sept_2008_Cost Model_LiftsIrish Constuction Industry Magazine_Sept_2008_Cost Model_Lifts
Irish Constuction Industry Magazine_Sept_2008_Cost Model_LiftsDavid Hughes
 
Design of Elevator Controller using Verilog HDL
Design of Elevator Controller using Verilog HDLDesign of Elevator Controller using Verilog HDL
Design of Elevator Controller using Verilog HDLVishesh Thakur
 
Catalogue Mitsubishi Elevator NexWay-S Ver2
Catalogue Mitsubishi Elevator NexWay-S Ver2Catalogue Mitsubishi Elevator NexWay-S Ver2
Catalogue Mitsubishi Elevator NexWay-S Ver2Thang máy Vinalift
 
Lifts and escalators
Lifts and escalatorsLifts and escalators
Lifts and escalatorsShubham Arora
 

Similar to Nex way design_ref (20)

building service - lift and escalators
building service - lift and escalatorsbuilding service - lift and escalators
building service - lift and escalators
 
Vertical transporation systems in building
Vertical transporation systems in buildingVertical transporation systems in building
Vertical transporation systems in building
 
Presentation on building service
Presentation on building servicePresentation on building service
Presentation on building service
 
STAIRS AND LIFTS IN ARCHIETCTURE
STAIRS AND LIFTS IN ARCHIETCTURESTAIRS AND LIFTS IN ARCHIETCTURE
STAIRS AND LIFTS IN ARCHIETCTURE
 
newelb_en5151615165156151561651_2203.pdf
newelb_en5151615165156151561651_2203.pdfnewelb_en5151615165156151561651_2203.pdf
newelb_en5151615165156151561651_2203.pdf
 
lift and escalator.pdf
lift and escalator.pdflift and escalator.pdf
lift and escalator.pdf
 
Catalogue thang máy Nexiez MRL
Catalogue thang máy Nexiez MRLCatalogue thang máy Nexiez MRL
Catalogue thang máy Nexiez MRL
 
Express product catalog
Express product catalogExpress product catalog
Express product catalog
 
Elevators and Escalators
 Elevators and Escalators Elevators and Escalators
Elevators and Escalators
 
Service core
Service coreService core
Service core
 
LE
LELE
LE
 
Lifts & Escalators
Lifts & EscalatorsLifts & Escalators
Lifts & Escalators
 
ELEVATOR SYSTEM IN DELHI METRO STATIONS
ELEVATOR SYSTEM IN DELHI METRO STATIONSELEVATOR SYSTEM IN DELHI METRO STATIONS
ELEVATOR SYSTEM IN DELHI METRO STATIONS
 
Arrangement of Escalators and Elevators
Arrangement of Escalators and ElevatorsArrangement of Escalators and Elevators
Arrangement of Escalators and Elevators
 
Catalogue Thang máy Mitsubishi_Series-NEXIEZ-MRL.pdf
Catalogue Thang máy Mitsubishi_Series-NEXIEZ-MRL.pdfCatalogue Thang máy Mitsubishi_Series-NEXIEZ-MRL.pdf
Catalogue Thang máy Mitsubishi_Series-NEXIEZ-MRL.pdf
 
Irish Constuction Industry Magazine_Sept_2008_Cost Model_Lifts
Irish Constuction Industry Magazine_Sept_2008_Cost Model_LiftsIrish Constuction Industry Magazine_Sept_2008_Cost Model_Lifts
Irish Constuction Industry Magazine_Sept_2008_Cost Model_Lifts
 
Design of Elevator Controller using Verilog HDL
Design of Elevator Controller using Verilog HDLDesign of Elevator Controller using Verilog HDL
Design of Elevator Controller using Verilog HDL
 
Catalogue Mitsubishi Elevator NexWay-S Ver2
Catalogue Mitsubishi Elevator NexWay-S Ver2Catalogue Mitsubishi Elevator NexWay-S Ver2
Catalogue Mitsubishi Elevator NexWay-S Ver2
 
ELEVATORS
ELEVATORSELEVATORS
ELEVATORS
 
Lifts and escalators
Lifts and escalatorsLifts and escalators
Lifts and escalators
 

More from stanjack99

Giao trinh khi_cu_dien_043
Giao trinh khi_cu_dien_043Giao trinh khi_cu_dien_043
Giao trinh khi_cu_dien_043stanjack99
 
Evnnpc kt qđ-01
Evnnpc kt qđ-01Evnnpc kt qđ-01
Evnnpc kt qđ-01stanjack99
 
Compact kiosk transformer
Compact kiosk transformerCompact kiosk transformer
Compact kiosk transformerstanjack99
 
Sgsu ex-203 model (1)
Sgsu ex-203 model (1)Sgsu ex-203 model (1)
Sgsu ex-203 model (1)stanjack99
 
Hitachi elevator, vfi ii (updated oct 2013) full
Hitachi elevator, vfi ii (updated oct 2013) fullHitachi elevator, vfi ii (updated oct 2013) full
Hitachi elevator, vfi ii (updated oct 2013) fullstanjack99
 
Lighting control panel
Lighting control panelLighting control panel
Lighting control panelstanjack99
 
Developingsprinklersystemdesigncriteriadnugentexpa
DevelopingsprinklersystemdesigncriteriadnugentexpaDevelopingsprinklersystemdesigncriteriadnugentexpa
Developingsprinklersystemdesigncriteriadnugentexpastanjack99
 

More from stanjack99 (9)

Giao trinh khi_cu_dien_043
Giao trinh khi_cu_dien_043Giao trinh khi_cu_dien_043
Giao trinh khi_cu_dien_043
 
Nfpa 110
Nfpa 110Nfpa 110
Nfpa 110
 
Evnnpc kt qđ-01
Evnnpc kt qđ-01Evnnpc kt qđ-01
Evnnpc kt qđ-01
 
Compact kiosk transformer
Compact kiosk transformerCompact kiosk transformer
Compact kiosk transformer
 
Sgsu ex-203 model (1)
Sgsu ex-203 model (1)Sgsu ex-203 model (1)
Sgsu ex-203 model (1)
 
Hitachi elevator, vfi ii (updated oct 2013) full
Hitachi elevator, vfi ii (updated oct 2013) fullHitachi elevator, vfi ii (updated oct 2013) full
Hitachi elevator, vfi ii (updated oct 2013) full
 
Lighting control panel
Lighting control panelLighting control panel
Lighting control panel
 
App fluke1653
App fluke1653App fluke1653
App fluke1653
 
Developingsprinklersystemdesigncriteriadnugentexpa
DevelopingsprinklersystemdesigncriteriadnugentexpaDevelopingsprinklersystemdesigncriteriadnugentexpa
Developingsprinklersystemdesigncriteriadnugentexpa
 

Recently uploaded

Cheap Rate Call girls Kalkaji 9205541914 shot 1500 night
Cheap Rate Call girls Kalkaji 9205541914 shot 1500 nightCheap Rate Call girls Kalkaji 9205541914 shot 1500 night
Cheap Rate Call girls Kalkaji 9205541914 shot 1500 nightDelhi Call girls
 
NO1 Famous Amil Baba In Karachi Kala Jadu In Karachi Amil baba In Karachi Add...
NO1 Famous Amil Baba In Karachi Kala Jadu In Karachi Amil baba In Karachi Add...NO1 Famous Amil Baba In Karachi Kala Jadu In Karachi Amil baba In Karachi Add...
NO1 Famous Amil Baba In Karachi Kala Jadu In Karachi Amil baba In Karachi Add...Amil baba
 
Raj Nagar Extension Call Girls 9711199012 WhatsApp No, Delhi Escorts in Raj N...
Raj Nagar Extension Call Girls 9711199012 WhatsApp No, Delhi Escorts in Raj N...Raj Nagar Extension Call Girls 9711199012 WhatsApp No, Delhi Escorts in Raj N...
Raj Nagar Extension Call Girls 9711199012 WhatsApp No, Delhi Escorts in Raj N...ankitnayak356677
 
如何办理(UVa毕业证书)弗吉尼亚大学毕业证毕业证(文凭)成绩单原版一比一定制
如何办理(UVa毕业证书)弗吉尼亚大学毕业证毕业证(文凭)成绩单原版一比一定制如何办理(UVa毕业证书)弗吉尼亚大学毕业证毕业证(文凭)成绩单原版一比一定制
如何办理(UVa毕业证书)弗吉尼亚大学毕业证毕业证(文凭)成绩单原版一比一定制didi bibo
 
VIP Kolkata Call Girl Gariahat 👉 8250192130 Available With Room
VIP Kolkata Call Girl Gariahat 👉 8250192130  Available With RoomVIP Kolkata Call Girl Gariahat 👉 8250192130  Available With Room
VIP Kolkata Call Girl Gariahat 👉 8250192130 Available With Roomdivyansh0kumar0
 
Kindergarten Assessment Questions Via LessonUp
Kindergarten Assessment Questions Via LessonUpKindergarten Assessment Questions Via LessonUp
Kindergarten Assessment Questions Via LessonUpmainac1
 
Cheap Rate Call girls Malviya Nagar 9205541914 shot 1500 night
Cheap Rate Call girls Malviya Nagar 9205541914 shot 1500 nightCheap Rate Call girls Malviya Nagar 9205541914 shot 1500 night
Cheap Rate Call girls Malviya Nagar 9205541914 shot 1500 nightDelhi Call girls
 
The history of music videos a level presentation
The history of music videos a level presentationThe history of music videos a level presentation
The history of music videos a level presentationamedia6
 
PORTFOLIO DE ARQUITECTURA CRISTOBAL HERAUD 2024
PORTFOLIO DE ARQUITECTURA CRISTOBAL HERAUD 2024PORTFOLIO DE ARQUITECTURA CRISTOBAL HERAUD 2024
PORTFOLIO DE ARQUITECTURA CRISTOBAL HERAUD 2024CristobalHeraud
 
WAEC Carpentry and Joinery Past Questions
WAEC Carpentry and Joinery Past QuestionsWAEC Carpentry and Joinery Past Questions
WAEC Carpentry and Joinery Past QuestionsCharles Obaleagbon
 
VIP Call Girls Service Kukatpally Hyderabad Call +91-8250192130
VIP Call Girls Service Kukatpally Hyderabad Call +91-8250192130VIP Call Girls Service Kukatpally Hyderabad Call +91-8250192130
VIP Call Girls Service Kukatpally Hyderabad Call +91-8250192130Suhani Kapoor
 
VIP Call Girl Amravati Aashi 8250192130 Independent Escort Service Amravati
VIP Call Girl Amravati Aashi 8250192130 Independent Escort Service AmravatiVIP Call Girl Amravati Aashi 8250192130 Independent Escort Service Amravati
VIP Call Girl Amravati Aashi 8250192130 Independent Escort Service AmravatiSuhani Kapoor
 
Call Girls In Safdarjung Enclave 24/7✡️9711147426✡️ Escorts Service
Call Girls In Safdarjung Enclave 24/7✡️9711147426✡️ Escorts ServiceCall Girls In Safdarjung Enclave 24/7✡️9711147426✡️ Escorts Service
Call Girls In Safdarjung Enclave 24/7✡️9711147426✡️ Escorts Servicejennyeacort
 
VIP Call Girls Service Bhagyanagar Hyderabad Call +91-8250192130
VIP Call Girls Service Bhagyanagar Hyderabad Call +91-8250192130VIP Call Girls Service Bhagyanagar Hyderabad Call +91-8250192130
VIP Call Girls Service Bhagyanagar Hyderabad Call +91-8250192130Suhani Kapoor
 
Call Girls in Okhla Delhi 💯Call Us 🔝8264348440🔝
Call Girls in Okhla Delhi 💯Call Us 🔝8264348440🔝Call Girls in Okhla Delhi 💯Call Us 🔝8264348440🔝
Call Girls in Okhla Delhi 💯Call Us 🔝8264348440🔝soniya singh
 
VIP Russian Call Girls in Saharanpur Deepika 8250192130 Independent Escort Se...
VIP Russian Call Girls in Saharanpur Deepika 8250192130 Independent Escort Se...VIP Russian Call Girls in Saharanpur Deepika 8250192130 Independent Escort Se...
VIP Russian Call Girls in Saharanpur Deepika 8250192130 Independent Escort Se...Suhani Kapoor
 
Kieran Salaria Graphic Design PDF Portfolio
Kieran Salaria Graphic Design PDF PortfolioKieran Salaria Graphic Design PDF Portfolio
Kieran Salaria Graphic Design PDF Portfolioktksalaria
 
VIP Russian Call Girls in Gorakhpur Deepika 8250192130 Independent Escort Ser...
VIP Russian Call Girls in Gorakhpur Deepika 8250192130 Independent Escort Ser...VIP Russian Call Girls in Gorakhpur Deepika 8250192130 Independent Escort Ser...
VIP Russian Call Girls in Gorakhpur Deepika 8250192130 Independent Escort Ser...Suhani Kapoor
 

Recently uploaded (20)

Cheap Rate Call girls Kalkaji 9205541914 shot 1500 night
Cheap Rate Call girls Kalkaji 9205541914 shot 1500 nightCheap Rate Call girls Kalkaji 9205541914 shot 1500 night
Cheap Rate Call girls Kalkaji 9205541914 shot 1500 night
 
Call Girls Service Mukherjee Nagar @9999965857 Delhi 🫦 No Advance VVIP 🍎 SER...
Call Girls Service Mukherjee Nagar @9999965857 Delhi 🫦 No Advance  VVIP 🍎 SER...Call Girls Service Mukherjee Nagar @9999965857 Delhi 🫦 No Advance  VVIP 🍎 SER...
Call Girls Service Mukherjee Nagar @9999965857 Delhi 🫦 No Advance VVIP 🍎 SER...
 
NO1 Famous Amil Baba In Karachi Kala Jadu In Karachi Amil baba In Karachi Add...
NO1 Famous Amil Baba In Karachi Kala Jadu In Karachi Amil baba In Karachi Add...NO1 Famous Amil Baba In Karachi Kala Jadu In Karachi Amil baba In Karachi Add...
NO1 Famous Amil Baba In Karachi Kala Jadu In Karachi Amil baba In Karachi Add...
 
Raj Nagar Extension Call Girls 9711199012 WhatsApp No, Delhi Escorts in Raj N...
Raj Nagar Extension Call Girls 9711199012 WhatsApp No, Delhi Escorts in Raj N...Raj Nagar Extension Call Girls 9711199012 WhatsApp No, Delhi Escorts in Raj N...
Raj Nagar Extension Call Girls 9711199012 WhatsApp No, Delhi Escorts in Raj N...
 
如何办理(UVa毕业证书)弗吉尼亚大学毕业证毕业证(文凭)成绩单原版一比一定制
如何办理(UVa毕业证书)弗吉尼亚大学毕业证毕业证(文凭)成绩单原版一比一定制如何办理(UVa毕业证书)弗吉尼亚大学毕业证毕业证(文凭)成绩单原版一比一定制
如何办理(UVa毕业证书)弗吉尼亚大学毕业证毕业证(文凭)成绩单原版一比一定制
 
VIP Kolkata Call Girl Gariahat 👉 8250192130 Available With Room
VIP Kolkata Call Girl Gariahat 👉 8250192130  Available With RoomVIP Kolkata Call Girl Gariahat 👉 8250192130  Available With Room
VIP Kolkata Call Girl Gariahat 👉 8250192130 Available With Room
 
Kindergarten Assessment Questions Via LessonUp
Kindergarten Assessment Questions Via LessonUpKindergarten Assessment Questions Via LessonUp
Kindergarten Assessment Questions Via LessonUp
 
Cheap Rate Call girls Malviya Nagar 9205541914 shot 1500 night
Cheap Rate Call girls Malviya Nagar 9205541914 shot 1500 nightCheap Rate Call girls Malviya Nagar 9205541914 shot 1500 night
Cheap Rate Call girls Malviya Nagar 9205541914 shot 1500 night
 
The history of music videos a level presentation
The history of music videos a level presentationThe history of music videos a level presentation
The history of music videos a level presentation
 
PORTFOLIO DE ARQUITECTURA CRISTOBAL HERAUD 2024
PORTFOLIO DE ARQUITECTURA CRISTOBAL HERAUD 2024PORTFOLIO DE ARQUITECTURA CRISTOBAL HERAUD 2024
PORTFOLIO DE ARQUITECTURA CRISTOBAL HERAUD 2024
 
young call girls in Pandav nagar 🔝 9953056974 🔝 Delhi escort Service
young call girls in Pandav nagar 🔝 9953056974 🔝 Delhi escort Serviceyoung call girls in Pandav nagar 🔝 9953056974 🔝 Delhi escort Service
young call girls in Pandav nagar 🔝 9953056974 🔝 Delhi escort Service
 
WAEC Carpentry and Joinery Past Questions
WAEC Carpentry and Joinery Past QuestionsWAEC Carpentry and Joinery Past Questions
WAEC Carpentry and Joinery Past Questions
 
VIP Call Girls Service Kukatpally Hyderabad Call +91-8250192130
VIP Call Girls Service Kukatpally Hyderabad Call +91-8250192130VIP Call Girls Service Kukatpally Hyderabad Call +91-8250192130
VIP Call Girls Service Kukatpally Hyderabad Call +91-8250192130
 
VIP Call Girl Amravati Aashi 8250192130 Independent Escort Service Amravati
VIP Call Girl Amravati Aashi 8250192130 Independent Escort Service AmravatiVIP Call Girl Amravati Aashi 8250192130 Independent Escort Service Amravati
VIP Call Girl Amravati Aashi 8250192130 Independent Escort Service Amravati
 
Call Girls In Safdarjung Enclave 24/7✡️9711147426✡️ Escorts Service
Call Girls In Safdarjung Enclave 24/7✡️9711147426✡️ Escorts ServiceCall Girls In Safdarjung Enclave 24/7✡️9711147426✡️ Escorts Service
Call Girls In Safdarjung Enclave 24/7✡️9711147426✡️ Escorts Service
 
VIP Call Girls Service Bhagyanagar Hyderabad Call +91-8250192130
VIP Call Girls Service Bhagyanagar Hyderabad Call +91-8250192130VIP Call Girls Service Bhagyanagar Hyderabad Call +91-8250192130
VIP Call Girls Service Bhagyanagar Hyderabad Call +91-8250192130
 
Call Girls in Okhla Delhi 💯Call Us 🔝8264348440🔝
Call Girls in Okhla Delhi 💯Call Us 🔝8264348440🔝Call Girls in Okhla Delhi 💯Call Us 🔝8264348440🔝
Call Girls in Okhla Delhi 💯Call Us 🔝8264348440🔝
 
VIP Russian Call Girls in Saharanpur Deepika 8250192130 Independent Escort Se...
VIP Russian Call Girls in Saharanpur Deepika 8250192130 Independent Escort Se...VIP Russian Call Girls in Saharanpur Deepika 8250192130 Independent Escort Se...
VIP Russian Call Girls in Saharanpur Deepika 8250192130 Independent Escort Se...
 
Kieran Salaria Graphic Design PDF Portfolio
Kieran Salaria Graphic Design PDF PortfolioKieran Salaria Graphic Design PDF Portfolio
Kieran Salaria Graphic Design PDF Portfolio
 
VIP Russian Call Girls in Gorakhpur Deepika 8250192130 Independent Escort Ser...
VIP Russian Call Girls in Gorakhpur Deepika 8250192130 Independent Escort Ser...VIP Russian Call Girls in Gorakhpur Deepika 8250192130 Independent Escort Ser...
VIP Russian Call Girls in Gorakhpur Deepika 8250192130 Independent Escort Ser...
 

Nex way design_ref

  • 1. DESIGN REFERENCE FOR ELEVATOR INSTALLATIONS NexWay
  • 2. ● Control, Door and Operation Systems Selective collective (2BC) The system consists of call buttons in the car, and a riser of up and down destination floor buttons installed at each elevator hall (single button at terminal floors), which connect electrically with microprocessors supervising floor selection and direction of travel. A car will respond to those car and hall calls that comply with its direction of service. When there are no more calls registered for the car’s direction of travel, the car’s service direction is reversed. ∑AI-22 & ∑AI-2200C Group Control Systems The systems, which employ an intelligent expert system and fuzzy logic, are specially designed for group control of 3 to 8 elevators (as described above). Practical information required for group control is stored in the system's memory as a “Knowledge Database”. Drawing from this database, various traffic conditions are monitored and analyzed applying IF-THEN decision rules to maximize the effectiveness of each elevator operation. The systems perform assignments to the most-used locations, and thereby provide superb efficiency and service. In addition to the above, ΣAI-2200C system performs optimal car allocation using Dynamic Rule-set Optimizer. 1 car 2 cars 3 cars 4 cars 5 cars 6 cars 7 cars 8 cars Number of elevators in a bank ● (1C-2BC) — — — — — — — — ● (2C-2BC) — — — — — — — — ● (3C-ΣAI-22) ● (4C-ΣAI-22) — — — — — — ● (3C-ΣAI-2200C) ● (4C-ΣAI-2200C) ● (5C-ΣAI-2200C) ● (6C-ΣAI-2200C) ● (7C-ΣAI-2200C) ● (8C-ΣAI-2200C) 1-car selective collective (Standard) 2-car group control system (optional) ΣAI-22 group control system (option) ΣAI-2200C group control system (option) VVVF control and Data Network System with multiple microprocessor modules (VFGH) VVVF control with microprocessor, 2-panel center opening <CO> (Standard), 2-panel side opening <2S> (option), 4-panel center opening <2CO> (option) Control system Door system Operation system ● Capacity and Speed *1 750 900 1050 1200 1350 1600 1800 2000 2250 2500 3000 10 12 14 16 18 21 24 26 30 33 40 ● ● ● ● ● ● ● ● 2.0 ● ● ● ● ● ● ● ● 2.5 3.0 3.5 4.0 ● ● ● ● ● ● ● ● 5.0 ● ● ● ● ● ● ● ● 6.0 7.0 8.0 9.0 10.0 EN81-1 Rated speed (m/sec)Rated capacity (kg) Number of persons ● Specifications *1 Rated speed (m/sec) Maximum number of stops 750kg 900kg 1050kg 1200kg 1350kg 1600kg 1800kg 2000kg 150 150 200 150 250 250 250 Maximum travel (m) *2 Minimum floor height (mm) 2500 *3 2.0 2.5 3.0 3.5 4.0 Please consult our local agents. Please consult our local agents. Please consult our local agents. Please consult our local agents. Please consult our local agents. 5.0 6.0 7.0 8.0 9.0 10.0 ●: Applicable —: Not applicable ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● 64 Notes: *1: Please consult our local agents if the maximum travel exceeds the values specified in the above table. *2: For the rated capacity 2250kg to 3000kg, please consult our local agents for maximum travel. *3: For some elevator specifications, the floor height (distance between floors) must be a minimum of 2500mm. Please consult our local agents if the floor height is less than “Entrance height HH + 700mm”. Notes: *1: The symbol shown in the table indicates that a technical inquiry is required. The symbol ● shown in the table indicates that a technical inquiry is required depending on conditions. *2: Refer to page 5 to 12 for the hoistway and machine room layout plans for the models with specifications marked in gray ( ). For the layouts for models with other specifications, please consult our local agents. BASIC SPECIFICATIONS OF THE NexWay 1 2
  • 3. ● Elevator installations should be properly planned according to such factors as the size and nature or kind of the building, the traffic flow and peak traffic demand or conditions, the location of public transportation facilities and stores. ● Dispersing elevators in different areas of a building adversely affects their passenger-carrying efficiency. Therefore, elevators should, as far as possible, be concentrated in the center of the building. ● When two groups of elevators face each other, ample space should be left between the groups. ● The number of elevators in each group should be decided on the basis of the physical arrangement of the elevators and the floors served. ● As much as possible, all the floors served by one group of elevators should be functionally and structurally similar. Dissimilarity among the floors served will result in a drop in service level. ● In residential buildings, hotels, and the like, it is not desirable for the elevator hall to be located farther than 50 meters from any apartment or room. ● In steel-reinforced concrete buildings, design the hoistways so that concrete walls are at least 120mm thick. ● Hoistways must be no more than 30mm out of plumb. ● No wiring or distribution panels should be built into or mounted on hoistway walls. ● It is forbidden under most building codes to install any conduit work or piping in hoistways except as required for the elevator itself. ● Pit-depth and overhead-height dimensions must always be at least the minimum shown in the drawings. ● If it proves necessary to make use of space below the pit, contact our local subcontractor. ● When the building is to be of steel construction, our local subcontractor should be brought into the discussion at the earliest possible moment. ● Provide the recommended width and height to assure that there will be sufficient room for inspection and maintenance. ● Since the elevator drive equipment generates considerable heat, sufficient ventilation and or air- conditioning capacity must be provided to assure that the machine-room temperature does not exceed 40°C. Refer to elevator site requirements at page 18 for details. ● When occupied areas of the building are in close proximity to the machine room, such as in the case of elevators for the low and middle floors of a high-rise building, it may be desirable to provide additional soundproofing or intervening walls. ● Some Examples of Bank Arrangements Desirable Plans ● Notes on Installation Planning Elevator Arrangement Points Relating to the Hoistway Points Relating to the Machine Room ● Selecting the Operation System Large-scale office building Recommended elevator speedMax. no. of floors served 60 floors 55 floors 50 floors 45 floors 40 floors 35 floors 30 floors 25 floors 20 floors 15 floors 10 floors 5 floors Scale of building Number of elevators Medium-scale office building Operation system 1 2 3 4 5 6 7 8 1-car selective collective (2BC) 2-car group control system (2BC) ∑AI-22 group control system ∑AI-2200C group control system Elevator traffic reaches a peak when people employed in the building arrive for work in the morning, when they break for lunch at midday, and when they leave for home in the evening. Obviously, the elevators must be capable of handling the increased traffic during these peaks. And during actual business hours, the elevators must be able to respond promptly to serve the people who are on the move inside the building as well as those who arrive at or leave the building. So that the elevators best suited to the conditions and environment at hand can be selected, Mitsubishi Electric applies computer simulation, traffic computation, and other techniques based on its wealth of experience in this field to offer a wide range of elevator consulting services. Given below are reference data useful for general planning. Selecting the Elevator Speed The maximum number of floors served in a building serves as the criterion for selecting the speed at which the elevators should travel. To select elevators using the chart below, if the building has 23 floors, select elevators with a speed of 3.5m/sec or 4.0m/sec. Note: The following chart shows the recommended elevator speed per maximum number of service floors. The best suited speed varies depending on the following factors: *Building usage; *Single-tenant building or multi-tenant building; *Floor heights; *Population in the building; *Number of elevators in the group; or *Capacity of the elevator. Please consult our local agents for details. Applicable system Recommended system Undesirable Plans 1.0m/sec 1.5 m/sec 1.75 m/sec 2.0 m/sec 2.5m/sec 3.0m/sec 3.5m/sec 4.0m/sec 5.0m/sec 6.0m/sec 7.0m/sec 8.0m/sec 9.0m/sec 10.0m/sec STANDARD INSTALLATIONREFERENCE DATA FOR ELEVATOR PLANNING 3 4
  • 4. Note: The dimensions OH are calculated when the car frame height (HB) is 3450mm. − − − − − − 750 900 1050 1350 1600 1800 2000 2080 2800 2080 2840 3050 3200 1200 3500 3600 3150 3300 3330 Rated capacity (kg) 2.0 2.5 3.0 Rated speed (m/sec) TR< =100 100<TR< =150 150<TR< =200 200<TR< =250 TR< =100 100<TR< =150 150<TR< =200 200<TR< =250 TR< =100 100<TR< =150 150<TR< =200 200<TR< =250 Travel TR (m) ★ All the above dimensions are calculated based on EN81-1 (1998). ★ The dimensions shown are minimum requirements, particularly in the figures of TC, OH and PD. Necessary tolerance should be separately considered for the building construction errors. ★ The dimensions TC, OH, PD and reaction load are calculated according to car and hoistway dimensions on the above table and conditions. Note: *1: The dimensions PD, OH and BH are calculated when the counterweight without safety gear is located in back of the car. P10 P12 P14 P16 P18 P21 P24 P26 P12 P14 P16 P18 P21 P24 P26 750 900 1050 1200 1350 1600 1800 2000 900 1050 1200 1350 1600 1800 2000 10 12 14 16 18 21 24 26 12 14 16 18 21 24 26 800 900 900 1000 1100 1100 1100 1100 900 900 1000 1100 1100 1100 1100 1400×1300 1600×1300 1600×1500 1800×1500 2000×1500 2000×1700 2100×1750 2100×1950 1600×1300 1600×1500 1800×1500 2000×1500 2000×1700 2100×1750 2100×1950 Car internal dimensions (mm) 1-unit installation 1900×2050 2100×2050 2100×2250 2300×2250 2500×2250 2500×2450 2600×2550 2600×2750 2100×2050 2100×2300 2300×2300 2500×2300 2500×2500 2600×2550 2600×2750 2-unit installation 3900×2050 4300×2050 4300×2250 4700×2250 5100×2250 5100×2450 5300×2550 5300×2750 4300×2050 4300×2300 4700×2300 5100×2300 5100×2500 5300×2550 5300×2750 2-unit installation 4500×3455 4700×3455 4700×3655 4900×3655 5100×3655 5100×3855 5400×3955 5400×4105 4700×3455 4700×3655 4900×3655 5100×3655 5100×3855 5400×3955 5400×4105 Width×Depth AA×BB Width×Depth AH×BH Width×Depth AH×BH Width×Depth AM×BM 2.0 2.5 3.0 Rated speed (m/sec) Code number Rated capacity (kg) Number of persons Entrance width JJ (mm) ● Dimension table of car, hoistway and machine room ● Overhead-height (OH) *1 ● Pit-depth (PD) *1 2.0 2.5 3.0 TR< =100 1760 1840 2190 100<TR< =250 1910 1990 2340 Travel (TR) (m) Rated speed (m/sec) ● Top clearance (TC) Layout example of in-line arrangement (Unit: mm) (Unit: mm) (Unit: mm) 2.0 2.5 3.0 Regulation EN81-1 2500 Rated speed (m/sec) ● Machine-room height (HM) (Unit: mm) In-line arrangement Internal dimensions of machine room (mm) Internal dimensions of hoistway (mm) *1 Rated capacity (kg)Rated speed (m/sec) 2.0 2.5 3.0 R1 R2 P1 P2 R1 R2 P1 P2 900 94 63 137 124 106 70 149 138 750 94 63 129 121 − 1050 123 82 178 164 157 105 205 200 1200 112 74 159 142 158 106 191 185 1350 149 100 191 182 160 106 196 182 1600 156 104 195 181 161 107 214 189 1800 174 116 227 196 191 127 245 215 2000 200 134 246 227 193 129 245 215 ● Reaction loads in machine room and pit Hoistway (Unit: kN) Elevation Machine room 100-125 AH AA JJ BB BH AM (min) R1 R2 Intercom (option) Ventilationwindow (byowner) Attachment panel Control panel Control panel BM(min) Power receiving box (by owner) Power outlet (by owner) Lighting outlet (by owner) Width:1000 Height:2000 Accessdoor:(byowner) Ventilator (byowner) Entranceheight: HH=2100 Hoisting hook or trolley beam (by owner) HM(min.) OH(min.) TCHB=3450 HL PD(min.)Travel(TR) Totalheight P1 P2 Cinder-concrete finish (by owner) Highest floor Lowest floor 33503330 2650 − − − − − 750 900 1050 1350 1600 1800 2000 5210 5360 5290 5440 5360 5440 5360 5440 1200 Rated capacity (kg) 2.0 2.5 3.0 Rated speed (m/sec) TR< =100 100<TR< =150 150<TR< =200 200<TR< =250 TR< =100 100<TR< =150 150<TR< =200 200<TR< =250 TR< =100 100<TR< =150 150<TR< =250 Travel TR (m) 5640 5790 5790 − − RATED SPEED OF 2.0~3.0 m/sec 5 6
  • 5. Note: The dimensions OH are calculated when the car frame height (HB) is 3450mm. 750 900 1050 3020 3370 16001200 − − − Rated capacity (kg) 3.5 4.0 Rated speed (m/sec) TR< =100 100<TR<< =150 150<TR<< =200 200<TR<< =250 TR<< =200 200<TR<< =250 Travel TR (m) ★ All the above dimensions are calculated based on EN81-1 (1998). ★ The dimensions shown are minimum requirements, particularly in the figures of TC, OH and PD. Necessary tolerance should be separately considered for the building construction errors. ★ The dimensions TC, OH, PD and reaction load are calculated according to car and hoistway dimensions on the above table and conditions. Notes: *1: The dimensions PD, OH and BH are calculated when the counterweight without safety gear is located in back of the car. *2: Traction machine for the rated capacity 1600kg differs depending on the car weight. *3: AM×BM is 5300×3855 only when the rated speed is 4.0m/sec and traction machine type is PML-F50. ● Dimension table of car, hoistway and machine room ● Overhead-height (OH) *1● Pit-depth (PD) *1 3.5 4.0 TR< =100 2520 3070 2670 100<TR< =150 150<TR< =250 Travel (TR) (m) Rated speed (m/sec) ● Top clearance (TC) (Unit: mm)(Unit: mm) (Unit: mm) 3.5 4.0 Regulation EN81-1 2500 Rated speed (m/sec) ● Machine-room height (HM) (Unit: mm) 4.0 3.5 ● Reaction loads in machine room and pit (Unit: kN) Rated capacity (kg) Rated speed (m/sec) R1 R2 P1 P2 R1 R2 P1 P2 900 106 70 149 138 750 − − − 1050 157 105 205 200 158 105 204 199 1200 158 106 196 185 159 106 194 185 1350 160 106 196 182 159 106 194 182 161 107 214 189 162 108 214 190 188 125 241 215 1800 191 127 245 215 191 127 245 215 2000 193 129 245 215 193 129 249 215 750 900 1050 5970 6120 1600 1800 20001200 − − 6120 6520 − − Rated capacity (kg) 3.5 4.0 Rated speed (m/sec) TR< =100 100<TR< =150 150<TR< =250 TR< =250 Travel TR (m) Hoistway Elevator lobby Machine room Lobbywidth: 3500-4500 100-125 BB BHBH JJ AAAH Ventilationwindow (byowner) Ventilator (by owner)R1 R2 Lighting outlet (by owner) Power receiving box (by owner) Power outlet (by owner) AM (min) Intercom (option) BM(min)=lobbywidth+2BH (byowner)Width:1000 Height:2000 Accessdoor: Attach- ment panel Attach- ment panel Attachment panel Attachment panel Control panel Control panel Control panel Control panel Control panel Control panel Group control panel Entranceheight: HH=2100 P2 P2P1 P1 Hoisting hook or trolley beam (by owner) HM(min.) OH(min.) TC HB= 3450 PD(min.)Travel(TR) Totalheight HL Cinder-concrete finish (by owner) Highest floor Lowest floor 3660 3760 3920 4020 1800 2000 Layout example of facing arrangement 1600 *2 PM040MR PML-F50 P12 P14 P16 P18 P21 P24 P26 900 1050 1200 1350 1600 1800 2000 12 14 16 18 21 24 26 900 900 1000 1100 1100 1100 1100 1600×1300 1600× 1500 1800× 1500 2000× 1500 2000× 1700 2100× 1750 2100×1950 Car internal dimensions (mm) 2-unit installation 4400× 2100 4400× 2300 4800× 2300 5200× 2300 5200× 2500 5400× 2550 5400× 2750 2-unit installation 4750× 3455 4750× 3655 4950×3655 5200×3655 5200×3855 *3 5400×3955 5400×4105 Width×Depth AA×BB Width×Depth AH×BH Width×Depth AM×BM 3.5 4.0 3.5 Rated speed (m/sec) Code number Rated capacity (kg) Number of persons Entrance width JJ (mm) In-line arrangement Internal dimensions of machine room (mm) Internal dimensions of hoistway (mm) *1 1350 1350 Elevation RATED SPEED OF 3.5, 4.0 m/sec 7 8
  • 6. 1200 1350 1600 1800 2000 Rated capacity (kg) 5.0 Rated speed (m/sec) TR< =150 150<TR< =200 200<TR< =250 4050 4350 4450 Travel TR (m) ★ All the above dimensions are calculated based on EN81-1 (1998). ★ The dimensions shown are minimum requirements, particularly in the figures of TC, OH and PD. Necessary tolerance should be separately considered for the building construction errors. ★ TC, OH, PD and reaction load are calculated according to car and hoistway dimensions on the above table. (When the counterweight is back drop.) ★ The shaft independently housing a single car is not recommended because noise increases. Please consult our local agents if the shaft of that kind is required. Note: *1: The dimensions BH are calculated when the counterweight is equipped without safety gear. ● Dimension table of car, hoistway and machine room ● Overhead-height (OH) dimensions● Pit-depth (PD) dimensions 5.0 TR< =150 3200 150<TR< =250 3600 Travel (TR) (m) Rated speed (m/sec) ● Top clearance (TC) dimensions (Unit: mm) (Unit: mm) (Unit: mm) ● Machine-room height (HM) (Unit: mm) ● Reaction loads in machine room and pit (Unit: kN) Hoistway Elevator lobby Machine room Lobbywidth: 3500-4500 100-125 BB BHBH Ventilationwindow (byowner) R1 R2 Lighting outlet (by owner) Power receiving box (by owner) AM (min) Width:1600or1900 Height:2000 Accessdoor (byowner): JJ AAAH Power outlet (by owner) BM(min)=lobbywidth+2BH 1200 1350 1600 1800 2000 Rated capacity (kg) 5.0 Rated speed (m/sec) TR< =150 150<TR< =250 6650 7050 Travel TR (m) Entranceheight: HH=2100 Travel(TR) Totalheight P2 P2P1 P1 HM(min.) OH(min.) TC PD(min.) HL Hoisting hook or trolley beam (by owner) Cinder-concrete finish (by owner) Highest floor Lowest floor Reactor panel Control panel Reactor panel Control panel Reactor panel Control panel Reactor panel Control panel Reactor panel Control panel Reactor panel Control panel Distribution panel Group control panel Intercom (option) Distribution panel Ventilator (by owner) 1200 1350 2300 1600 2300 1800 2000 Rated capacity (kg) 5.0 Rated speed (m/sec) TR< =150 150<TR< =250 2800 Travel (TR) (m) Layout example of facing arrangement Note: The dimensions OH are calculated when the car frame height (HB) is 3450mm. HB= 3450 1200 165 110 215 205 1350 175 120 215 210 1600 185 125 225 205 1800 195 130 240 220 2000 195 130 240 220 Rated capacity (kg) 5.0 Rated speed (m/sec) R1 R2 P1 P2 ● Dimension table of car, hoistway and machine room P16 P18 P21 P24 P26 1200 1350 1600 1800 2000 16 18 21 24 26 1000 1100 1100 1100 1100 1800× 1450 2000× 1450 2000× 1700 2100× 1750 2100×1950 Car internal dimensions (mm) 2-unit installation 5100× 2300 5500× 2300 5500× 2550 5700× 2650 5700× 2850 2-unit installation 5300×4000 5500×4000 5500×4250 5700×4300 5700×4450 Width×Depth AA×BB Width×Depth AH×BH Width×Depth AM×BM 5.0 Rated speed (m/sec) Code number Rated capacity (kg) Number of persons Entrance width JJ (mm) In-line arrangement Internal dimensions of machine room (mm) Internal dimensions of hoistway (mm) *1 Elevation RATED SPEED OF 5.0 m/sec 9 10
  • 7. ★ All the above dimensions are calculated based on EN81-1 (1998). ★ The dimensions shown are minimum requirements, particularly in the figures of TC, OH and PD. Necessary tolerance should be separately considered for the building construction errors. ★ TC, OH, PD and reaction load are calculated according to car and hoistway dimensions on the above table. (When the counterweight is back drop.) ★ The shaft independently housing a single car is not recommended because noise increases. Please consult our local agents if the shaft of that kind is required. Note: *1: The dimensions BH are calculated when the counterweight is equipped without safety gear. Hoistway Elevator lobby Machine room Lobbywidth: 3500-4500 100-125 Ventilationwindow (byowner) R2 Width:1600or1900 Height:2000 Accessdoor (byowner): BM(min)=lobbywidth+2BH Entranceheight: HH=2100 P2 P2P1 P1 HM(min.) OH(min.) TC PD(min.) HL BB BHBH JJ AAAH Lighting outlet (by owner) Power receiving box (by owner) Power outlet (by owner) Hoisting hook or trolley beam (by owner) Highest floor Lowest floor Cinder-concrete finish (by owner) Travel(TR) Totalheight Reactor panel Control panel Reactor panel Control panel Reactor panel Control panel Reactor panel Control panel Reactor panel Control panel Reactor panel Control panel Distribution panel Group control panel Intercom (option) Distribution panel R1 AM (min) Ventilator (by owner) 6.0 TR< =150 3200 150<TR< =250 3600 Travel (TR) (m) Rated speed (m/sec) ● Top clearance (TC) dimensions (Unit: mm) ● Machine-room height (HM) (Unit: mm) 1200 1350 2300 1600 2300 1800 2000 Rated capacity (kg) 6.0 Rated speed (m/sec) TR< =150 150<TR< =250 2800 Travel (TR) (m) 1200 1350 1600 1800 2000 Rated capacity (kg) 6.0 Rated speed (m/sec) TR< =150 150<TR< =200 200<TR< =250 4050 4350 4450 Travel TR (m) ● Pit-depth (PD) dimensions (Unit: mm)● Reaction loads in machine room and pit (Unit: kN) 1200 170 115 215 210 1350 170 115 215 205 1600 185 125 230 215 1800 195 130 240 220 2000 195 130 240 220 Rated capacity (kg) 6.0 Rated speed (m/sec) R1 R2 P1 P2 Layout example of facing arrangement ● Overhead-height (OH) dimensions (Unit: mm) 1200 1350 1600 1800 2000 Rated capacity (kg) 6.0 Rated speed (m/sec) TR< =150 150<TR< =250 6650 7050 Travel TR (m) Note: The dimensions OH are calculated when the car frame height (HB) is 3450mm. HB= 3450 ● Dimension table of car, hoistway and machine room● Dimension table of car, hoistway and machine room P16 P18 P21 P24 P26 1200 1350 1600 1800 2000 16 18 21 24 26 1000 1100 1100 1100 1100 1800× 1450 2000× 1450 2000× 1700 2100× 1750 2100×1950 Car internal dimensions (mm) 2-unit installation 5100× 2300 5500× 2300 5500× 2600 5700× 2650 5700× 2850 2-unit installation 5250×4000 5550×4000 5550×4250 5700×4300 5700×4450 Width×Depth AA×BB Width×Depth AH×BH Width×Depth AM×BM 6.0 Rated speed (m/sec) Code number Rated capacity (kg) Number of persons Entrance width JJ (mm) In-line arrangement Internal dimensions of machine room (mm) Internal dimensions of hoistway (mm) *1 Elevation RATED SPEED OF 6.0 m/sec 11 12
  • 8. Type E-102 (standard) Type E-302, E-312 (option) Building structure (by owner) Wall and floor finishing (by owner) Note: 1. Triangular key-hole is required under EN81-1. 2. Details in sections A-A and B-B are not for BS-476 fire rated doors. Door plan (section B-B) Hoistway entrance Door elevation (section A-A) Building structure (by owner) Wall and floor finishing (by owner) Note: 1. Triangular key-hole is required under EN81-1. 2. Details in sections A-A and B-B are not for BS-476 fire rated doors. ENTRANCE LAYOUT DRAWINGS 13 14
  • 9. ● Power Feeder Data *1 FLU: current during upward operation with full load at power supply voltage of 400V. FLAcc: current while accelerating with full load at power supply voltage of 400V. Notes: *1: The values in the table above are for the case where power supply voltage is 400V. If the power supply voltage is within the range of 380 to 440V (except for 400V), calculate values by referring to page 16. If the power supply voltage is not within the range of 380 to 440V, please consult our local agents. *2: If power supply voltage (E) is a value other than 400V, FLU current and FLAcc current are obtained via the following formula. (FLU/FLAcc current (A) at E (V)) = (Current at 400V) × (400/E (V)) 2.0 2.5 3.0 3.5 4.0 5.0 6.0 750 900 1050 1200 1350 1600 1800 2000 750 900 1050 1200 1350 1600 1800 2000 750 900 1050 1200 1350 1600 1800 2000 750 900 1050 1200 1350 1600 1800 2000 750 900 1050 1200 1350 1600 1800 2000 1200 1350 1600 1800 2000 1200 1350 1600 1800 2000 15 15 15 20 20 20 23 28 18 18 18 25 25 25 28 35 22 22 22 30 30 30 34 42 25 25 25 35 35 35 39 49 29 29 29 40 40 40 45 56 42 42 50 53 58 56 56 56 63 70 27 31 33 37 41 47 57 59 31 36 39 44 48 56 67 70 34 39 45 50 56 65 76 81 40 44 51 57 63 74 92 94 44 49 57 64 71 83 102 104 80 88 103 114 126 92 102 120 133 147 52 56 61 67 72 82 98 107 64 69 75 82 88 100 121 134 74 81 90 98 105 119 143 163 97 99 113 124 131 144 174 197 110 112 123 135 143 165 196 231 196 211 238 253 274 237 252 284 304 328 16 18 19 21 23 26 31 33 18 20 21 23 25 29 34 37 19 21 23 25 28 32 40 42 21 23 27 30 33 37 46 47 23 26 30 33 36 41 49 51 41 44 50 57 62 46 50 59 65 72 75 75 75 75 75 75 100 100 75 75 75 75 75 100 100 100 75 75 75 100 100 100 125 125 75 75 100 100 100 125 125 150 75 100 100 125 125 150 150 150 125 125 150 175 200 150 150 175 200 225 2330 2800 3260 3730 4190 4970 5600 6210 2910 3490 4070 4660 5240 6210 7000 7800 3490 4190 4890 5590 6280 7450 8400 9400 4070 4890 5700 6520 7330 8690 9800 10860 4660 5590 6520 7450 8380 9930 11200 12410 9400 10500 12500 14000 15600 11200 12600 14900 16800 18700 Speed (m/sec) Rated load (kg) Traction motor (kW) Capacity of power supply (kVA) NF in M/R at 400V system (A) Heat emission (W) Current at 400V *2 FLU (A) FLAcc (A) The feeder must be able to withstand continuous flow of the following current at an ambient temperature of 40°C. 1.25 × FLU (A)……FLU <= 50 (A) 1.10 × FLU (A)……FLU > 50 (A) (FLU (A): current during upward operation with full load at power supply voltage of 400V.) The wire length for the feeder size must be calculated via the following formula. Wire length (m) <= Coefficient* × E (V)/FLAcc (A) (E: power supply voltage (V)) (FLAcc (A): current while accelerating with full load at power supply voltage of 400V) *Refer to the table 1 for coefficients. When power is supplied to multiple elevators in a group through a common feeder, the capacity of the power supply transformer, the size of the feeder, and the current rating of the no-fuse (NF) breaker for one elevator are each multiplied by the corresponding diversity factor at table 2. Feeder Size Calculation With express zoneWithout express zone Diversity factor For FLAcc For FLU No. of elevators on common feeder Table 2 Feeder size (mm2 ) Coefficient Table 1 3.5 5.5 8 14 22 30 38 50 60 80 100 125 150 200 250 325 2 3 4 5 6 7 8 9 10 2.0 2.7 3.1 3.25 3.3 3.71 4.08 4.45 4.8 1.7 2.4 2.95 3.6 4.1 4.6 5.1 5.6 6.0 1.85 2.7 3.4 4.2 4.9 5.6 6.3 6.9 7.6 5.1 8.0 11.6 20.6 32.1 42.5 54.3 70.7 87.3 115 148 184 225 287 371 473 ● ● ELECTRICAL INSTALLATION 15 16
  • 10. Traction-Machinery Power Supply It is necessary to install power-supply equipment of sufficient capacity to ensure the elevators accelerating smoothly and landing accurately. The power supply should be kept within a voltage- fluctuation range of +5 ~ -10%, and a voltage- imbalance factor of 5%. When selecting protective breakers on the power- supply side, be guided by voltage ratings of the no-fuse breakers supplied with the elevators. Ventilation Equipment A machine-room ventilation device having a sufficient capacity to keep the room temperature below 40°C is required. A ventilation window should also be installed at the opposite side of ventilation fan. Power Supply for Lighting Lighting for the elevator cars and indicators, where possible, should be supplied via a separate circuit that will not be affected by power failures elsewhere. Intercom (where necessary) This is essential to establish the communication between elevator passengers and outside in case of emergency. The master station transceiver is usually in a location readily accessible to the supervisor, in the central supervisor's room or elevator lobby. The wiring work between the master station and the elevator machine room is not included in the elevator contract. To facilitate piping and wiring, it is desirable to decide on the position of the master station at the earliest stage of building design. Lighting Equipment The machine room should be fitted with good lighting for maintenance work. The light switch should be positioned close to the machine-room entrance. Inspection Power Outlets These should be installed in the machine room and pit for use during inspection and maintenance. ● Electrical Equipment Required for Elevator Operation Notes: *1: The minimum size of ground wire is determined according to the ampere rating of the NF breaker installed at the power source side. *2: The ampere rating of the power-source NF breaker should be of one step larger than of the receiving-box NF breaker installed in the elevator machine room. NF breaker *2 Ground wire *1 The following items are excluded from Mitsubishi Electric’s elevator installation work, and are therefore the responsibility of the building owner or general contractor: • Construction of the elevator machine room with proper beams and slabs, equipped with a lock, complete with illumination, ventilation and waterproofing. • Access to the elevator machine room sufficient to allow passage of the control panel and traction machine. • Architectural finishing of the machine room floor, and the walls and floors in the vicinity of the entrance hall after installation has been completed. • Construction of an illuminated, ventilated and waterproofed elevator hoistway. • A ladder to the elevator pit. • The provision of cutting the necessary openings and joists. • Separate beams, when the hoistway dimensions markedly exceed the specifications, and intermediate beams when two or more elevators are installed. • All other work related to building construction. • The machine room power-receiving panel and the electrical wiring for illumination, plus the electrical wiring from the electrical room to the power-receiving panel. • The laying of conduits and wiring between the elevator pit and the terminating point for the devices installed outside the hoistway, such as the emergency bell, intercom, monitoring and security devices, etc. • The power consumed in installation work and test operations. • All the necessary building materials for grouting in of brackets, bolts, etc. • The test provision and subsequent alteration as required, and eventual removal of the scaffolding as required by the elevator contractor, and any other protection of the work as may be required during the process. • The provision of a suitable, locked space for the storage of elevator equipment and tools during elevator installation. • The security system, such as a card reader, connected to Mitsubishi Electric's elevator controller, when supplied by the building owner or general contractor. * Work responsibilities in installation and construction shall be determined according to local laws. Please consult our local agents for details. Work Not Included in Elevator Contract • The temperature of the machine room and elevator hoistway shall be below 40˚C. • The following conditions are required for maintaining elevator performance. a. The relative humidity shall be below 90% on a monthly average and below 95% on a daily average. b. The machine room and the elevator hoistway shall be finished with mortar or other materials so as to prevent concrete dust. c. Prevention shall be provided against icing and condensation occurring due to a rapid drop in the temperature in the machine room and elevator hoistway. • Voltage fluctuation shall be within a range of +5% to -10%. Elevator Site Requirements Please include the following information when ordering or requesting estimates: • The desired number of units, speed and loading capacity. • The number of stops or number of floors to be served. • The total elevator travel and each floor-to-floor height. • Operation system. • Selected design and size of car. • Entrance design. • Signal equipment. • A sketch of the part of the building where the elevators are to be installed. • The voltage, number of phases, and frequency of the power source for the motor and lighting. Ordering Information Mitsubishi Elevator Inazawa Works has acquired ISO 9001 certification by the International Standards Organization (ISO) based on a review of quality management. The company has also acquired environmental management system standard ISO 14001 certification. NOTES ON INSTALLATION PLANNINGELECTRICAL INSTALLATION 17 18
  • 11. C-CL1-4-C9343-A INA-1403 Printed in Japan (MDOC) New publication effective Mar. 2014. Specifications are subject to change without notice. 2014 Eco Changes is the Mitsubishi Electric Group’s environmental statement, and expresses the Group’s stance on environmental management. Through a wide range of businesses, we are helping contribute to the realization of a sustainable society. Visit our website at: http://www.mitsubishielectric.com/elevator/