Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Datasheet SpruceTrigen 41 NG 50Hz
1. 0
5
10
15
20
25
30
35
40
45
0 1 2 3 4 5 6 7
Power,kW
Electric Load, kW
Input and Total Power VS Electric Load
Total Power, kW Input Power, kW
0
15
30
45
60
75
90
105
120
135
150
0 1 2 3 4 5 6 7
Efficiency,%
Electric Load, kW
Consumer Electrical and Total Efficiency VS Electric Load
Total Efficiency, % Consumer electrical Efficiency, %
Model SpruceTrigen 41 NG 50Hz
Power Plant
Gas Engine
VANGUARD 570cc V-TWIN
Gross. power 9,8kW at 3000rpm
Alternator Model 50Hz
SINCRO EK 2 LCA 115V/230V
1 phase 120V/240V
Net Electric Power 7 kW
Radiator Fan Power input 0,1 kW
Freon Loop
Freon Compressor Model R410a
SANYO - C-SBP120H15A
220-240V/1/50Hz
Freon Compressor Power input 2,6 kW
Compressor COP cooling 4,35 W/W
Compressor COP heating 5,25 W/W
Dimensions, Weight and Working Conditions
External air temperature -30…+45 ⁰С
Weight (Fluid filled) 200 kg
Acoustic impact (measured at 7 meters) 66 dB(A)
Dimensions (H x W x L) 77 x 72 x 148 cm
Power*
Electric energy for Consumer 4,3 kW
Hot water 1 (70/50 ⁰C) 11,4 kW
Hot water 2 (45/30 ⁰C) 13,7 kW
Cold water (12/7 ⁰C) 11,3 kW
Full power 41 kW
Fuel consumption (Natural Gas) 3,4 m3/h
Input power 35,3 kW
Total efficiency 115 %
DATASHEET
SNGEHeat&Power
POLITECHNIC
Kharkiv 1885
https://serikovzhenya.wixsite.com/snge
Serikov.zhenya@gmail.com
Phone/Viber/Telegram/WhatsApp:
+380502450524
SNGE Heat&Power
14a Lisova St., Gora, Kyiv region, Ukraine
Compressor ON
Compressor OFF
Compressor ON
Compressor OFF
* Power @ data recorded at the rated electric power and water outlet of 70°C unless specified; methane @ 20mbar, the data
related to 37 MJ/m3; air inlet @ 25°C and 101.3 kPa