Gurgaon ✡️9711147426✨Call In girls Gurgaon Sector 51 escort service
Datasheet SpruceTrigen 66 50hz Biogas
1. 0
10
20
30
40
50
60
70
0 2 4 6 8 10
Power,kW
Electric Load, kW
Input and Total Power VS Electric Load
Total Power, kW Input Power, kW
0
20
40
60
80
100
120
140
160
180
200
0 2 4 6 8 10
Efficiency,%
Electric Load, kW
Consumer Electrical and Total Efficiency VS Electric Load
Total Efficiency, % Consumer electrical Efficiency, %
Model SpruceTrigen 66 Biogas 50Hz
Power Plant
Gas Engine
Kohler CH-1000
Max. power 12,8kW at 3000rpm
Alternator Model 50Hz
SINCRO FT2 MER 230V/400V
3 phase
Net Electric Power 10 kW
Radiator Fan Power input 0,2 kW
Freon Loop
Freon Compressor Model R410a
SANYO - C-SDP225H38A
380-415V/3/50Hz
Freon Compressor Power input 4,7 kW
Compressor COP cooling 4,4 W/W
Compressor COP heating 5,3 W/W
Dimensions, Weight and Working Conditions
External air temperature -30…+45 ⁰С
Weight (Fluid filled) 310 kg
Acoustic impact (measured at 7 meters) 69 dB(A)
Dimensions (H x W x L) 77 x 72 x 158 cm
Power*
Electric energy for Consumer 5,1 kW
Hot water 1 (70/50 ⁰C) 15,7 kW
Hot water 2 (45/30 ⁰C) 24,9 kW
Cold water (12/7 ⁰C) 20,7 kW
Full power 66 kW
Fuel consumption (Biogas**) 7,6 m3/h
Input power 49,1 kW
Total efficiency 135 %
DATASHEET
SNGEHeat&Power
POLITECHNIC
Kharkiv 1885
https://serikovzhenya.wixsite.com/snge
Serikov.zhenya@gmail.com
Phone/Viber/Telegram/WhatsApp:
+380502450524
SNGE Heat&Power
14a Lisova St., Gora, Kyiv region, Ukraine
Compressor ON
Compressor OFF
Compressor ON
Compressor OFF
* Power @ data recorded at the rated electric power and water outlet of 70°C unless specified; methane @ 20mbar, the data
related to 23,3 MJ/m3; air inlet @ 25°C and 101.3 kPa
** Biogas (CH4 – 65%, CO2 – 35%)