Features
• Compatible with all Morley-IAS                                                                                                  The Active repeater includes an integral self test
  intelligent multi-protocol fire alarm                                                                                           sequence guiding the operator through a preset
  control panels                                                                                                                  sequence to test the functionality of the control
                                                                                                                                  buttons, key-switch and display indicators.
• Connects to RS485 peripheral bus
• Active or Passive options                                                                                                       Each repeater is connected to the Morley-IAS fire
                                                                                                                                  alarm control panels using the RS485 peripheral data
• Backlit adjustable alphanumeric display                                                                                         port as shown in the schematic overleaf. A maximum
• General status LEDs                                                                                                             of 31 active repeaters can be connected to the
• Controls for system reset, accept, mute,                                                                                        peripheral data port. The fire alarm control panel
  silence alarms, and self test (active                                                                                           supervises the connection between itself and the
  repeater only)                                                                                                                  repeater, proving the integrity of the cabling and
                                                                                                                                  indicating faults both on the repeater and the fire
• “Access Enable” key-switch on active                                                                                            alarm control panel. Passive repeaters are not
  repeater                                                                                                                        supervised, but a loss of communication with the fire
                                                                                                                                  alarm control panel will be indicated on the passive
The Morley-IAS repeaters are compact remote control units for                                                                     repeater.
Morley-IAS intelligent multi protocol fire alarm control panels.
These units, along with other I/O peripheral devices and the                                                                      The repeater requires an external power supply of
external printer further enhance the flexibility and functionality                                                                 +24Vdc (nominal) to operate. Power may be taken
of our fire alarmcontrol panel range.                                                                                              from the auxillary supply of the control panel or from
                                                                                                                                  any other suitable dc power supply.
The repeaters provide an extension to the operation of the fire
alarm control panel. There are two types available - passive
with indications only and no controls, or active with both
controls and indicators. Both display the operational state of
the control panel using the 80 character LCD display and the 7
LED status indicators.

In addition to the general status indicators the Active repeater
is fitted with key operated “Access Enable” switch for the
control functions. Individual buttons are provided for System
Reset, Mute, Accept, Sound Alarms, Silence/Re-sound Alarms
and Self test. Thus enabling control functions to be duplicated
in strategic locations around the installation.




ZXr-A & ZXr-P
Repeaters
Data Sheet
Every care has been taken in the preparation of this datasheet but no liability can be accepted for the use of the information therein.
Design features may be changed or amended without prior notice. © Morley-IAS by Honeywell 2008.
Mechanical                                                                 Electrical
Weight:                        1.7Kg (approx)                              Operating voltage
Operating Temperature:         +5ºC to +45ºC                                   18 to 32 Vdc

Maximum Humidity:              10% to 93% non-condensing                   Operating Current
                                                                               90mA (Quiescent) 120m (Alarm)
                                                                           Terminals
                                                                               Maximum cross section 2.5mm2
                                                                           LED indicators
                                                                               Fire, Fault, Disables, Accepted, Silenced, Power,
                                                                               Communications, loss.
                                                                           EXrA User Controls:
                                                                               Keyswitch activated - System Reset, Sound Alarms,
                                                                               Silence/Resound, Mute, Accept and Self Test




                                                                           Part Numbers
                                                                           709-601-001        ZXr-A Active Repeater.
                                                                           709-601-101        ZXr-A Active Repeater UL listed
                                                                           709-701-001        ZXr-P Passive Repeater.
                                                                           709-701-101        ZXr-P Passive Repeater UL listed.
                                                                           002-600-002        Repeater Bezel.
                                                                           795-004-001        RS485 Communication Module.




Fire System Compatibility
Morley-IAS is fully committed to offering practical solutions and supporting products that enhance your buildings control systems.

Other Supporting Products Include
•   Morley-IAS   Intelligent Public Address and Voice Alarm Equipment
•   Morley-IAS   ZX range of networkable analogue addressable Fire Alarm Panels
•   Morley-IAS   Dimension Analogue Addressable Panels
•   Morley-IAS   Horizon Conventional Panels
•   Morley-IAS   Extinguishing Panels
For further details on these or any other Morley-IAS product please contact your local distribution point, Morley-IAS Regional Sales Manager or
via our contact details.

Morley-IAS by Honeywell a real choice for fire solutions, committed to supporting our device partners.




                                                                                        Charles Avenue          T: +44 (0) 1444 23 55 56
                                                                                        Burgess Hill            F: +44 (0) 1444 25 44 10
                                                                                        West Sussex             E: sales@morleyias.co.uk
                                                                                        RH15 9UF UK             www.morley-ias.co.uk

More Related Content

What's hot

In-wall dimmer module Z-Wave Plus Smart Home Europe manual english
In-wall dimmer module Z-Wave Plus Smart Home Europe manual englishIn-wall dimmer module Z-Wave Plus Smart Home Europe manual english
In-wall dimmer module Z-Wave Plus Smart Home Europe manual english
Domotica daVinci
 
Remote Operated Spy Robot Circuit
Remote Operated Spy Robot CircuitRemote Operated Spy Robot Circuit
Remote Operated Spy Robot Circuit
laibaNoor60
 
ZME WALLC-S manual
ZME WALLC-S manualZME WALLC-S manual
ZME WALLC-S manual
Domotica daVinci
 
Manual QUBINO zmnhwd1
Manual QUBINO zmnhwd1Manual QUBINO zmnhwd1
Manual QUBINO zmnhwd1
Domotica daVinci
 
Qubino dimmer manual
Qubino dimmer manualQubino dimmer manual
Qubino dimmer manual
Domotica daVinci
 
Exj 8 u
Exj 8 uExj 8 u
Qubino flush dimmer 0 10-v plus user manual_v1.0_eng
Qubino flush dimmer 0 10-v plus user manual_v1.0_engQubino flush dimmer 0 10-v plus user manual_v1.0_eng
Qubino flush dimmer 0 10-v plus user manual_v1.0_eng
Domotica daVinci
 
Soundcraft Epm Mpm
Soundcraft Epm MpmSoundcraft Epm Mpm
Soundcraft Epm Mpm
milesocampo
 
Edwards Signaling ANS25MDR Installation Manual
Edwards Signaling ANS25MDR Installation ManualEdwards Signaling ANS25MDR Installation Manual
Edwards Signaling ANS25MDR Installation Manual
JMAC Supply
 
Data sheet en_us_1893651851
Data sheet en_us_1893651851Data sheet en_us_1893651851
Data sheet en_us_1893651851
amthanhbosch
 
54762 01 vsp_vs523_dz_ycah
54762 01 vsp_vs523_dz_ycah54762 01 vsp_vs523_dz_ycah
54762 01 vsp_vs523_dz_ycah
Accurate Pool & Spa Services, llc
 
Edgereadererp40 ds en
Edgereadererp40 ds enEdgereadererp40 ds en
Edgereadererp40 ds en
sanzen enterprises
 
Evr hac01 in_en
Evr hac01 in_enEvr hac01 in_en
Evr hac01 in_en
Domotica daVinci
 
ASL Intercom PS155
ASL Intercom PS155ASL Intercom PS155
ASL Intercom PS155
AV ProfShop
 
Widom Z-WAve On/off relay switch 2.5KW manual English
Widom Z-WAve On/off relay switch 2.5KW  manual EnglishWidom Z-WAve On/off relay switch 2.5KW  manual English
Widom Z-WAve On/off relay switch 2.5KW manual English
Domotica daVinci
 

What's hot (15)

In-wall dimmer module Z-Wave Plus Smart Home Europe manual english
In-wall dimmer module Z-Wave Plus Smart Home Europe manual englishIn-wall dimmer module Z-Wave Plus Smart Home Europe manual english
In-wall dimmer module Z-Wave Plus Smart Home Europe manual english
 
Remote Operated Spy Robot Circuit
Remote Operated Spy Robot CircuitRemote Operated Spy Robot Circuit
Remote Operated Spy Robot Circuit
 
ZME WALLC-S manual
ZME WALLC-S manualZME WALLC-S manual
ZME WALLC-S manual
 
Manual QUBINO zmnhwd1
Manual QUBINO zmnhwd1Manual QUBINO zmnhwd1
Manual QUBINO zmnhwd1
 
Qubino dimmer manual
Qubino dimmer manualQubino dimmer manual
Qubino dimmer manual
 
Exj 8 u
Exj 8 uExj 8 u
Exj 8 u
 
Qubino flush dimmer 0 10-v plus user manual_v1.0_eng
Qubino flush dimmer 0 10-v plus user manual_v1.0_engQubino flush dimmer 0 10-v plus user manual_v1.0_eng
Qubino flush dimmer 0 10-v plus user manual_v1.0_eng
 
Soundcraft Epm Mpm
Soundcraft Epm MpmSoundcraft Epm Mpm
Soundcraft Epm Mpm
 
Edwards Signaling ANS25MDR Installation Manual
Edwards Signaling ANS25MDR Installation ManualEdwards Signaling ANS25MDR Installation Manual
Edwards Signaling ANS25MDR Installation Manual
 
Data sheet en_us_1893651851
Data sheet en_us_1893651851Data sheet en_us_1893651851
Data sheet en_us_1893651851
 
54762 01 vsp_vs523_dz_ycah
54762 01 vsp_vs523_dz_ycah54762 01 vsp_vs523_dz_ycah
54762 01 vsp_vs523_dz_ycah
 
Edgereadererp40 ds en
Edgereadererp40 ds enEdgereadererp40 ds en
Edgereadererp40 ds en
 
Evr hac01 in_en
Evr hac01 in_enEvr hac01 in_en
Evr hac01 in_en
 
ASL Intercom PS155
ASL Intercom PS155ASL Intercom PS155
ASL Intercom PS155
 
Widom Z-WAve On/off relay switch 2.5KW manual English
Widom Z-WAve On/off relay switch 2.5KW  manual EnglishWidom Z-WAve On/off relay switch 2.5KW  manual English
Widom Z-WAve On/off relay switch 2.5KW manual English
 

Similar to Z xra zxrp_repeaters

Ia cf3000 prg-c-r1
Ia cf3000 prg-c-r1Ia cf3000 prg-c-r1
Ia cf3000 prg-c-r1
sanzen enterprises
 
Zx range datasheet_0611
Zx range datasheet_0611Zx range datasheet_0611
Zx range datasheet_0611
sanzen enterprises
 
Data sheet en_us_1871477643
Data sheet en_us_1871477643Data sheet en_us_1871477643
Data sheet en_us_1871477643
amthanhbosch
 
7SR220 Overcurrent Relay
7SR220 Overcurrent Relay7SR220 Overcurrent Relay
7SR220 Overcurrent Relay
ashwini reliserv
 
YSI 5500D 5400 and 5200A aquaculture monitors and controllers
YSI 5500D 5400 and 5200A aquaculture monitors and controllersYSI 5500D 5400 and 5200A aquaculture monitors and controllers
YSI 5500D 5400 and 5200A aquaculture monitors and controllers
Xylem Inc.
 
Eclipse manual
Eclipse manualEclipse manual
Eclipse manual
Darwin Aguilar Ascencio
 
Data sheet en_us_1860652043
Data sheet en_us_1860652043Data sheet en_us_1860652043
Data sheet en_us_1860652043
amthanhbosch
 
5808spec
5808spec5808spec
5808spec
Sean Sullivan
 
Data sheet en_us_1889956491
Data sheet en_us_1889956491Data sheet en_us_1889956491
Data sheet en_us_1889956491
amthanhbosch
 
Cfs0065 ccat-r1-4 part7
Cfs0065 ccat-r1-4 part7Cfs0065 ccat-r1-4 part7
Cfs0065 ccat-r1-4 part7
sanzen enterprises
 
It 12000
It 12000It 12000
7SR224 Overcurrent Protection Relay
7SR224 Overcurrent Protection Relay7SR224 Overcurrent Protection Relay
7SR224 Overcurrent Protection Relay
ashwini reliserv
 
Adi jul1311
Adi jul1311Adi jul1311
Grx3000
Grx3000Grx3000
Grx3000
Nikola
 
Numerical protection 2
Numerical protection 2Numerical protection 2
Numerical protection 2
angila95
 
Data sheet en_us_1893111307
Data sheet en_us_1893111307Data sheet en_us_1893111307
Data sheet en_us_1893111307
amthanhbosch
 
Gst101
Gst101Gst101
Gst101
Adit Group
 
7SR10 Overcurrent Relay
7SR10 Overcurrent Relay7SR10 Overcurrent Relay
7SR10 Overcurrent Relay
ashwini reliserv
 
Data sheet en_us_1872223499
Data sheet en_us_1872223499Data sheet en_us_1872223499
Data sheet en_us_1872223499
amthanhbosch
 
Vertx v100 ds_en
Vertx v100 ds_enVertx v100 ds_en
Vertx v100 ds_en
sanzen enterprises
 

Similar to Z xra zxrp_repeaters (20)

Ia cf3000 prg-c-r1
Ia cf3000 prg-c-r1Ia cf3000 prg-c-r1
Ia cf3000 prg-c-r1
 
Zx range datasheet_0611
Zx range datasheet_0611Zx range datasheet_0611
Zx range datasheet_0611
 
Data sheet en_us_1871477643
Data sheet en_us_1871477643Data sheet en_us_1871477643
Data sheet en_us_1871477643
 
7SR220 Overcurrent Relay
7SR220 Overcurrent Relay7SR220 Overcurrent Relay
7SR220 Overcurrent Relay
 
YSI 5500D 5400 and 5200A aquaculture monitors and controllers
YSI 5500D 5400 and 5200A aquaculture monitors and controllersYSI 5500D 5400 and 5200A aquaculture monitors and controllers
YSI 5500D 5400 and 5200A aquaculture monitors and controllers
 
Eclipse manual
Eclipse manualEclipse manual
Eclipse manual
 
Data sheet en_us_1860652043
Data sheet en_us_1860652043Data sheet en_us_1860652043
Data sheet en_us_1860652043
 
5808spec
5808spec5808spec
5808spec
 
Data sheet en_us_1889956491
Data sheet en_us_1889956491Data sheet en_us_1889956491
Data sheet en_us_1889956491
 
Cfs0065 ccat-r1-4 part7
Cfs0065 ccat-r1-4 part7Cfs0065 ccat-r1-4 part7
Cfs0065 ccat-r1-4 part7
 
It 12000
It 12000It 12000
It 12000
 
7SR224 Overcurrent Protection Relay
7SR224 Overcurrent Protection Relay7SR224 Overcurrent Protection Relay
7SR224 Overcurrent Protection Relay
 
Adi jul1311
Adi jul1311Adi jul1311
Adi jul1311
 
Grx3000
Grx3000Grx3000
Grx3000
 
Numerical protection 2
Numerical protection 2Numerical protection 2
Numerical protection 2
 
Data sheet en_us_1893111307
Data sheet en_us_1893111307Data sheet en_us_1893111307
Data sheet en_us_1893111307
 
Gst101
Gst101Gst101
Gst101
 
7SR10 Overcurrent Relay
7SR10 Overcurrent Relay7SR10 Overcurrent Relay
7SR10 Overcurrent Relay
 
Data sheet en_us_1872223499
Data sheet en_us_1872223499Data sheet en_us_1872223499
Data sheet en_us_1872223499
 
Vertx v100 ds_en
Vertx v100 ds_enVertx v100 ds_en
Vertx v100 ds_en
 

More from sanzen enterprises

Odyssey 3
Odyssey 3Odyssey 3
Vm3240va ce cb1e
Vm3240va ce cb1eVm3240va ce cb1e
Vm3240va ce cb1e
sanzen enterprises
 
Vm 3240 e
Vm 3240 eVm 3240 e
Sv200ma mi1e
Sv200ma mi1eSv200ma mi1e
Sv200ma mi1e
sanzen enterprises
 
Sc610 cs1e
Sc610 cs1eSc610 cs1e
Sc610 cs1e
sanzen enterprises
 
Sc610 cs1e
Sc610 cs1eSc610 cs1e
Sc610 cs1e
sanzen enterprises
 
Cs154 cs1e
Cs154 cs1eCs154 cs1e
Cs154 cs1e
sanzen enterprises
 
Bs678 cs1e tei rev1
Bs678 cs1e tei rev1Bs678 cs1e tei rev1
Bs678 cs1e tei rev1
sanzen enterprises
 
Bs633a data sheet
Bs633a data sheetBs633a data sheet
Bs633a data sheet
sanzen enterprises
 
Data sheet en_us_1902186891
Data sheet en_us_1902186891Data sheet en_us_1902186891
Data sheet en_us_1902186891
sanzen enterprises
 
Data sheet en_us_1902186891
Data sheet en_us_1902186891Data sheet en_us_1902186891
Data sheet en_us_1902186891
sanzen enterprises
 
Data sheet en_us_1911721995
Data sheet en_us_1911721995Data sheet en_us_1911721995
Data sheet en_us_1911721995
sanzen enterprises
 
La1 uw24 x column loudspeakers
La1 uw24 x column loudspeakersLa1 uw24 x column loudspeakers
La1 uw24 x column loudspeakers
sanzen enterprises
 
Bgt 4139 ts
Bgt 4139 tsBgt 4139 ts
Bgt 4139 ts
sanzen enterprises
 
Bgt 5504 a
Bgt 5504 aBgt 5504 a
Bgt 5504 a
sanzen enterprises
 
Bgt 5140 a
Bgt 5140 aBgt 5140 a
Bgt 5140 a
sanzen enterprises
 
Bgt 9120 ts
Bgt 9120 tsBgt 9120 ts
Bgt 9120 ts
sanzen enterprises
 
Bgt 9119 as
Bgt 9119 asBgt 9119 as
Bgt 9119 as
sanzen enterprises
 
Bgt 720 tos
Bgt 720 tosBgt 720 tos
Bgt 720 tos
sanzen enterprises
 
Bgt 5221 as
Bgt 5221 asBgt 5221 as
Bgt 5221 as
sanzen enterprises
 

More from sanzen enterprises (20)

Odyssey 3
Odyssey 3Odyssey 3
Odyssey 3
 
Vm3240va ce cb1e
Vm3240va ce cb1eVm3240va ce cb1e
Vm3240va ce cb1e
 
Vm 3240 e
Vm 3240 eVm 3240 e
Vm 3240 e
 
Sv200ma mi1e
Sv200ma mi1eSv200ma mi1e
Sv200ma mi1e
 
Sc610 cs1e
Sc610 cs1eSc610 cs1e
Sc610 cs1e
 
Sc610 cs1e
Sc610 cs1eSc610 cs1e
Sc610 cs1e
 
Cs154 cs1e
Cs154 cs1eCs154 cs1e
Cs154 cs1e
 
Bs678 cs1e tei rev1
Bs678 cs1e tei rev1Bs678 cs1e tei rev1
Bs678 cs1e tei rev1
 
Bs633a data sheet
Bs633a data sheetBs633a data sheet
Bs633a data sheet
 
Data sheet en_us_1902186891
Data sheet en_us_1902186891Data sheet en_us_1902186891
Data sheet en_us_1902186891
 
Data sheet en_us_1902186891
Data sheet en_us_1902186891Data sheet en_us_1902186891
Data sheet en_us_1902186891
 
Data sheet en_us_1911721995
Data sheet en_us_1911721995Data sheet en_us_1911721995
Data sheet en_us_1911721995
 
La1 uw24 x column loudspeakers
La1 uw24 x column loudspeakersLa1 uw24 x column loudspeakers
La1 uw24 x column loudspeakers
 
Bgt 4139 ts
Bgt 4139 tsBgt 4139 ts
Bgt 4139 ts
 
Bgt 5504 a
Bgt 5504 aBgt 5504 a
Bgt 5504 a
 
Bgt 5140 a
Bgt 5140 aBgt 5140 a
Bgt 5140 a
 
Bgt 9120 ts
Bgt 9120 tsBgt 9120 ts
Bgt 9120 ts
 
Bgt 9119 as
Bgt 9119 asBgt 9119 as
Bgt 9119 as
 
Bgt 720 tos
Bgt 720 tosBgt 720 tos
Bgt 720 tos
 
Bgt 5221 as
Bgt 5221 asBgt 5221 as
Bgt 5221 as
 

Z xra zxrp_repeaters

  • 1. Features • Compatible with all Morley-IAS The Active repeater includes an integral self test intelligent multi-protocol fire alarm sequence guiding the operator through a preset control panels sequence to test the functionality of the control buttons, key-switch and display indicators. • Connects to RS485 peripheral bus • Active or Passive options Each repeater is connected to the Morley-IAS fire alarm control panels using the RS485 peripheral data • Backlit adjustable alphanumeric display port as shown in the schematic overleaf. A maximum • General status LEDs of 31 active repeaters can be connected to the • Controls for system reset, accept, mute, peripheral data port. The fire alarm control panel silence alarms, and self test (active supervises the connection between itself and the repeater only) repeater, proving the integrity of the cabling and indicating faults both on the repeater and the fire • “Access Enable” key-switch on active alarm control panel. Passive repeaters are not repeater supervised, but a loss of communication with the fire alarm control panel will be indicated on the passive The Morley-IAS repeaters are compact remote control units for repeater. Morley-IAS intelligent multi protocol fire alarm control panels. These units, along with other I/O peripheral devices and the The repeater requires an external power supply of external printer further enhance the flexibility and functionality +24Vdc (nominal) to operate. Power may be taken of our fire alarmcontrol panel range. from the auxillary supply of the control panel or from any other suitable dc power supply. The repeaters provide an extension to the operation of the fire alarm control panel. There are two types available - passive with indications only and no controls, or active with both controls and indicators. Both display the operational state of the control panel using the 80 character LCD display and the 7 LED status indicators. In addition to the general status indicators the Active repeater is fitted with key operated “Access Enable” switch for the control functions. Individual buttons are provided for System Reset, Mute, Accept, Sound Alarms, Silence/Re-sound Alarms and Self test. Thus enabling control functions to be duplicated in strategic locations around the installation. ZXr-A & ZXr-P Repeaters Data Sheet Every care has been taken in the preparation of this datasheet but no liability can be accepted for the use of the information therein. Design features may be changed or amended without prior notice. © Morley-IAS by Honeywell 2008.
  • 2. Mechanical Electrical Weight: 1.7Kg (approx) Operating voltage Operating Temperature: +5ºC to +45ºC 18 to 32 Vdc Maximum Humidity: 10% to 93% non-condensing Operating Current 90mA (Quiescent) 120m (Alarm) Terminals Maximum cross section 2.5mm2 LED indicators Fire, Fault, Disables, Accepted, Silenced, Power, Communications, loss. EXrA User Controls: Keyswitch activated - System Reset, Sound Alarms, Silence/Resound, Mute, Accept and Self Test Part Numbers 709-601-001 ZXr-A Active Repeater. 709-601-101 ZXr-A Active Repeater UL listed 709-701-001 ZXr-P Passive Repeater. 709-701-101 ZXr-P Passive Repeater UL listed. 002-600-002 Repeater Bezel. 795-004-001 RS485 Communication Module. Fire System Compatibility Morley-IAS is fully committed to offering practical solutions and supporting products that enhance your buildings control systems. Other Supporting Products Include • Morley-IAS Intelligent Public Address and Voice Alarm Equipment • Morley-IAS ZX range of networkable analogue addressable Fire Alarm Panels • Morley-IAS Dimension Analogue Addressable Panels • Morley-IAS Horizon Conventional Panels • Morley-IAS Extinguishing Panels For further details on these or any other Morley-IAS product please contact your local distribution point, Morley-IAS Regional Sales Manager or via our contact details. Morley-IAS by Honeywell a real choice for fire solutions, committed to supporting our device partners. Charles Avenue T: +44 (0) 1444 23 55 56 Burgess Hill F: +44 (0) 1444 25 44 10 West Sussex E: sales@morleyias.co.uk RH15 9UF UK www.morley-ias.co.uk