The MIU872 is a single zone micro interface unit that can connect up to 20 conventional fire detectors to an intelligent fire alarm panel. It has built-in short circuit isolation and monitors the input zone for open and short circuit faults. Installation is quick and simple as it requires no addressing and can use existing wiring.
The document summarizes the MCIM micro single channel input unit, which is used to support Menvier fire control panels. The MCIM provides a single input that can monitor contacts like sprinkler switches. It is compact, soft addressed, and has built-in short circuit isolation. Variants include the MCIM-NF for non-fire uses and MCIM-C, which is identified as a callpoint.
The document describes the R6000 range of intelligent addressable rack mounted control panels from Cooper Lighting and Safety. The R6000 consists of modular plug-in components that can be configured for functions like fire detection, alarm signaling, and plant control. The system supports up to 126 panels, 504 loops, and 64,512 addressable points. The floor rack unit houses the R6000 control panels and is constructed of mild steel.
The CF3000PRG passive repeater panel has a 2 x 40 backlit LCD display and 6 supervisory LEDs. It can be programmed to display information from a connected control panel, including fire alarms. It provides limited control functions like silencing alarms. With up to 20 repeaters connected, it offers a cost-effective way to display system status at multiple locations with minimal wiring and no required programming.
The VertX V100 Door/Reader Interface connects two access control card readers and controls one or two doors. It features on-board flash memory for program updates, connects to the V1000 host controller via RS-485, and the V1000 communicates with the host system via TCP/IP. The V100 processes access control decisions locally and reports all activity to the V1000.
This document provides guidance on measuring jitter and wander using the Acterna ANT-20 Advanced Network Tester. It discusses:
1. Measuring output jitter at device interfaces and outlines the instrument setup and application settings required.
2. Describes the different jitter measurements that can be taken, including peak-to-peak jitter, RMS jitter, phase hits, mapping jitter, and combined jitter.
3. Explains how to measure wander, including the instrument setup for offline wander analysis, measuring clock sources, and devices under test. Tolerances and pointer wander are also covered.
4. Notes that international standards define limits for jitter and wander at network interfaces to ensure compatibility.
The System Sensor Model BEAM1224 is a single-ended reflected beam smoke detector suited for protecting large, high-ceiling areas. It has a detection range of 16 to 328 feet and uses a transmitter/receiver unit and reflector. When smoke is detected between the units, an alarm is activated. The BEAM1224 has adjustable sensitivity levels and automatic sensitivity adjustment settings. It also features an integral sensitivity test option to allow for easy testing.
The document describes the MCOM micro single channel output unit, which is a small, soft-addressed interface unit that can be used to switch low-voltage circuits like HVAC or fire doors. It has an integral short circuit isolator, compact size, and connects to Menvier intelligent fire panels. Variants include the MCOM-R, which provides a 5-second reset pulse, and MCOM-S, which is identified as a sounder.
The XV GPRS control panel is a wireless, battery-operated security system that works with Videofied's devices. It has programmable inputs and outputs, supports 25 wireless devices, stores event logs and videos, and communicates using GPRS. It provides video verification from motion detectors and can trigger videos upon events. The control panel supervises connected devices and has tamper detection, multiple power options, and programming via keypad.
The document summarizes the MCIM micro single channel input unit, which is used to support Menvier fire control panels. The MCIM provides a single input that can monitor contacts like sprinkler switches. It is compact, soft addressed, and has built-in short circuit isolation. Variants include the MCIM-NF for non-fire uses and MCIM-C, which is identified as a callpoint.
The document describes the R6000 range of intelligent addressable rack mounted control panels from Cooper Lighting and Safety. The R6000 consists of modular plug-in components that can be configured for functions like fire detection, alarm signaling, and plant control. The system supports up to 126 panels, 504 loops, and 64,512 addressable points. The floor rack unit houses the R6000 control panels and is constructed of mild steel.
The CF3000PRG passive repeater panel has a 2 x 40 backlit LCD display and 6 supervisory LEDs. It can be programmed to display information from a connected control panel, including fire alarms. It provides limited control functions like silencing alarms. With up to 20 repeaters connected, it offers a cost-effective way to display system status at multiple locations with minimal wiring and no required programming.
The VertX V100 Door/Reader Interface connects two access control card readers and controls one or two doors. It features on-board flash memory for program updates, connects to the V1000 host controller via RS-485, and the V1000 communicates with the host system via TCP/IP. The V100 processes access control decisions locally and reports all activity to the V1000.
This document provides guidance on measuring jitter and wander using the Acterna ANT-20 Advanced Network Tester. It discusses:
1. Measuring output jitter at device interfaces and outlines the instrument setup and application settings required.
2. Describes the different jitter measurements that can be taken, including peak-to-peak jitter, RMS jitter, phase hits, mapping jitter, and combined jitter.
3. Explains how to measure wander, including the instrument setup for offline wander analysis, measuring clock sources, and devices under test. Tolerances and pointer wander are also covered.
4. Notes that international standards define limits for jitter and wander at network interfaces to ensure compatibility.
The System Sensor Model BEAM1224 is a single-ended reflected beam smoke detector suited for protecting large, high-ceiling areas. It has a detection range of 16 to 328 feet and uses a transmitter/receiver unit and reflector. When smoke is detected between the units, an alarm is activated. The BEAM1224 has adjustable sensitivity levels and automatic sensitivity adjustment settings. It also features an integral sensitivity test option to allow for easy testing.
The document describes the MCOM micro single channel output unit, which is a small, soft-addressed interface unit that can be used to switch low-voltage circuits like HVAC or fire doors. It has an integral short circuit isolator, compact size, and connects to Menvier intelligent fire panels. Variants include the MCOM-R, which provides a 5-second reset pulse, and MCOM-S, which is identified as a sounder.
The XV GPRS control panel is a wireless, battery-operated security system that works with Videofied's devices. It has programmable inputs and outputs, supports 25 wireless devices, stores event logs and videos, and communicates using GPRS. It provides video verification from motion detectors and can trigger videos upon events. The control panel supervises connected devices and has tamper detection, multiple power options, and programming via keypad.
The document summarizes the specifications of the VXD-720 digital portable radio. The radio operates on the DMR Tier 2 digital standard and can also communicate with analog radios, allowing for an easy transition to digital. It has 512 channels, long battery life of up to 40% longer than analog radios, and supports both voice and text communications. The radio is submersible to 3 feet and meets FCC narrowbanding requirements.
The IntelliKnight 5808 is a single loop, addressable fire alarm control panel that provides 127 detection points and integrated communication capabilities. It performs self-diagnostics on connected sensors and includes features like drift compensation. The basic panel can be expanded with additional modules. Notifications are powered by the onboard 6A power supply or an optional expansion module.
This document provides specifications for the MF RC500, a highly integrated reader IC that supports ISO 14443A contactless communication. The MF RC500 has an integrated analog front-end to interface with an antenna, and supports cryptography and authentication of MIFARE Classic cards. It includes a parallel interface that can connect to various microcontrollers. The document describes the device's features, block diagram, pinout, electrical specifications, and applications in areas such as transportation and access control.
Stability under Large-Signal Conditions PresentationNMDG NV
This presentation demonstrates calibrated small-signal S-parameters extraction under large-signal conditions, performed in parallel with the calibrated large-signal measurements provided by the ZVxPlus nonlinear extension kits.
The extracted S-parameters allow calculating the different stability criteria as well as the stability circles over the full frequency bandwidth of the selected network analyser.
The document describes the SpectrAlert Advance series of indoor wall-mountable horns, strobes, and horn strobes. It has several key features:
- Plug-in design for fast installation with minimal intrusion into the back box.
- Tamper-resistant construction and universal mounting plate.
- Field-selectable settings for voltage, candela, tone, and volume.
- Automatic selection of 12- or 24-volt operation to simplify installation.
1. The Fibaro Door/Window Sensor is a wireless, battery powered, Z-Wave compatible reed sensor that detects opening and closing of doors and windows.
2. It supports connection of one DS18B20 temperature sensor and has one potential free input that can be connected to a switch.
3. The document provides instructions on inclusion of the sensor to a Z-Wave network, resetting the sensor, and controlling it through a Home Center 2 controller.
The 5351E is a conventional rate-of-rise and fixed temperature thermal detector that features low current draw, backward compatibility with existing bases, and an addressable and programmable design. It provides efficient fire detection while incorporating an ASIC chip and latest thermal sensing technology. The detector can be programmed and tested using a remote handheld unit, allowing maintenance functions without removing the detector from its base. A variety of compatible bases are available to suit different panels and applications.
The VXD-R70 is a digital repeater that operates on the DMR protocol, allowing it to be compatible with other DMR radios. It can operate in both analog and digital modes, providing an easy transition to digital. Using TDMA technology, it doubles call capacity without needing additional frequency licenses. It has features such as an LED status indicator, power supply backup, and meets FCC narrowbanding requirements.
This document provides information on the H355(A) Series thermal detectors from Fire-Lite Alarms. The detectors are addressable sensors that use thermistor technology to detect heat. They can detect a fixed temperature of 135°F, or a rate of rise of 15°F per minute. The detectors plug into an intelligent base and connect to the fire alarm control panel via an SLC loop. They include LEDs to indicate alarm and normal status.
The document summarizes the MiniDySC 50 Amps voltage sag corrector from SoftSwitching Technologies. It is designed to protect sensitive electronic components from short-term voltage sags and drops. It features a proprietary double conversion power core, the fastest sag detection and response time on the market of 1 ms, and true sinusoidal reconstruction of output voltage. It is ideal for protecting PLCs, sensors, power supplies and other industrial control components.
wiDom Smart Roller Shutter Z-Wave Plus Module ManualDomotica daVinci
The document provides instructions for installing and operating the WiDom Smart Roller Shutter, a Z-Wave enabled device for controlling roller shutters, blinds, and curtains. It can accurately control opening and closing positions through local or remote commands. After an initial calibration, it identifies the position without sensors. Safety information warns that installation requires qualified electricians and live voltages are present. Installation instructions explain connecting it according to the diagrams and including it in a Z-Wave network. The LED status indicator shows inclusion status and communication events.
The EdgeReader ER40 is an IP access control solution that combines a controller and host interface in a single unit with an integrated iCLASS reader. It provides network access over CAT-5 cable and Power over Ethernet, eliminating separate power supplies. It stores up to 44,000 cards and controls all access functions at the door.
With the WiDom flush-mounted Double Switch Relay, you can integrate existing electrical installations (e.g. lighting, airing systems…) into a Z-Wave network.
The document summarizes the VertX V200 input monitor interface, which connects up to 16 supervised input circuits for alarm systems. It reports the status of input points and connects to the V1000 interface over RS-485. The V200 has flash memory for firmware updates, LED indicators, terminal connectors, and an enclosure that protects its components.
1) The document describes the Digital Contact Controller (DCC) made by ATLab, a Korean company located in Yongin-shi.
2) The DCC uses a fully digital architecture for capacitive touch sensing and is used in applications such as portable electronics, home electronics, and office equipment.
3) Key features of the DCC include low power consumption, fast response time, water resistance, ESD durability, and interference suppression between multiple touch points.
The 2351E photoelectric smoke detector is part of Honeywell's Series 300 range of conventional detectors. It features an ASIC chip and optical chamber for accurate fire detection with resilience to environmental factors. It has automatic drift compensation to maintain a consistent alarm threshold between services. The detector's sensitivity can be optimized through three preset alarm levels and programmed via a remote handheld unit, which also provides maintenance information like chamber contamination. It is compatible with Series 100 detector bases and includes a bi-color LED status indicator.
Manual del dispositivo regulador oculto Z-Wave de Widom que permite variar la intensidad de una lámpara, o la velocidad de un motor (como por ejemplo un ventilador).
The document describes the MCOM micro single channel output unit, which is a small, soft-addressed interface unit that can be used to switch low-voltage circuits like HVAC or fire doors. It has an integral short circuit isolator, compact size, and connects to Menvier intelligent fire panels. Variants include the MCOM-R, which provides a 5-second reset pulse, and MCOM-S, which is identified as a sounder.
The document summarizes the Cooper CF1000VDS range of intelligent addressable fire alarm control panels. Key points:
- The CF1000VDS range includes 1-loop and 2-loop control panels approved to EN54 standards.
- The panels offer up to 200 addresses per loop, network capability up to 126 panels, and features like soft addressing and a touchscreen user interface.
- Benefits include simple operation, flexible network and programming capabilities, and compatibility with a range of accessories.
The MSI850 spur isolator unit allows a spur of intelligent addressable devices to connect to the main loop. It simplifies installing remote parts of buildings or simple extensions. It has integral short circuit isolators for the loop and spur, and automatically controls addressing. It is quick and easy to install, and reduces costs by using existing wiring without needing external isolators.
The Honeywell 5806W3 is a wireless photoelectric smoke detector that sends alarm, tamper, and low battery signals to a wireless receiver. It uses advanced algorithms and a microprocessor to reduce false alarms from dust or contaminants. A removable cover allows technicians to easily clean the detector chamber without disassembling the unit. The wireless design makes installation simple without running wires.
The document describes a conventional fire alarm panel that includes:
- Microprocessor control and SMT electronics compliant with various standards
- Detection of up to 25 fire detectors and call points on one zone
- Two output control points to control indicators like sounders and strobes
- Standby batteries, fault and alarm indicators, and short circuit detection
- Simple installation and operation via a key switch
The document summarizes the specifications of the VXD-720 digital portable radio. The radio operates on the DMR Tier 2 digital standard and can also communicate with analog radios, allowing for an easy transition to digital. It has 512 channels, long battery life of up to 40% longer than analog radios, and supports both voice and text communications. The radio is submersible to 3 feet and meets FCC narrowbanding requirements.
The IntelliKnight 5808 is a single loop, addressable fire alarm control panel that provides 127 detection points and integrated communication capabilities. It performs self-diagnostics on connected sensors and includes features like drift compensation. The basic panel can be expanded with additional modules. Notifications are powered by the onboard 6A power supply or an optional expansion module.
This document provides specifications for the MF RC500, a highly integrated reader IC that supports ISO 14443A contactless communication. The MF RC500 has an integrated analog front-end to interface with an antenna, and supports cryptography and authentication of MIFARE Classic cards. It includes a parallel interface that can connect to various microcontrollers. The document describes the device's features, block diagram, pinout, electrical specifications, and applications in areas such as transportation and access control.
Stability under Large-Signal Conditions PresentationNMDG NV
This presentation demonstrates calibrated small-signal S-parameters extraction under large-signal conditions, performed in parallel with the calibrated large-signal measurements provided by the ZVxPlus nonlinear extension kits.
The extracted S-parameters allow calculating the different stability criteria as well as the stability circles over the full frequency bandwidth of the selected network analyser.
The document describes the SpectrAlert Advance series of indoor wall-mountable horns, strobes, and horn strobes. It has several key features:
- Plug-in design for fast installation with minimal intrusion into the back box.
- Tamper-resistant construction and universal mounting plate.
- Field-selectable settings for voltage, candela, tone, and volume.
- Automatic selection of 12- or 24-volt operation to simplify installation.
1. The Fibaro Door/Window Sensor is a wireless, battery powered, Z-Wave compatible reed sensor that detects opening and closing of doors and windows.
2. It supports connection of one DS18B20 temperature sensor and has one potential free input that can be connected to a switch.
3. The document provides instructions on inclusion of the sensor to a Z-Wave network, resetting the sensor, and controlling it through a Home Center 2 controller.
The 5351E is a conventional rate-of-rise and fixed temperature thermal detector that features low current draw, backward compatibility with existing bases, and an addressable and programmable design. It provides efficient fire detection while incorporating an ASIC chip and latest thermal sensing technology. The detector can be programmed and tested using a remote handheld unit, allowing maintenance functions without removing the detector from its base. A variety of compatible bases are available to suit different panels and applications.
The VXD-R70 is a digital repeater that operates on the DMR protocol, allowing it to be compatible with other DMR radios. It can operate in both analog and digital modes, providing an easy transition to digital. Using TDMA technology, it doubles call capacity without needing additional frequency licenses. It has features such as an LED status indicator, power supply backup, and meets FCC narrowbanding requirements.
This document provides information on the H355(A) Series thermal detectors from Fire-Lite Alarms. The detectors are addressable sensors that use thermistor technology to detect heat. They can detect a fixed temperature of 135°F, or a rate of rise of 15°F per minute. The detectors plug into an intelligent base and connect to the fire alarm control panel via an SLC loop. They include LEDs to indicate alarm and normal status.
The document summarizes the MiniDySC 50 Amps voltage sag corrector from SoftSwitching Technologies. It is designed to protect sensitive electronic components from short-term voltage sags and drops. It features a proprietary double conversion power core, the fastest sag detection and response time on the market of 1 ms, and true sinusoidal reconstruction of output voltage. It is ideal for protecting PLCs, sensors, power supplies and other industrial control components.
wiDom Smart Roller Shutter Z-Wave Plus Module ManualDomotica daVinci
The document provides instructions for installing and operating the WiDom Smart Roller Shutter, a Z-Wave enabled device for controlling roller shutters, blinds, and curtains. It can accurately control opening and closing positions through local or remote commands. After an initial calibration, it identifies the position without sensors. Safety information warns that installation requires qualified electricians and live voltages are present. Installation instructions explain connecting it according to the diagrams and including it in a Z-Wave network. The LED status indicator shows inclusion status and communication events.
The EdgeReader ER40 is an IP access control solution that combines a controller and host interface in a single unit with an integrated iCLASS reader. It provides network access over CAT-5 cable and Power over Ethernet, eliminating separate power supplies. It stores up to 44,000 cards and controls all access functions at the door.
With the WiDom flush-mounted Double Switch Relay, you can integrate existing electrical installations (e.g. lighting, airing systems…) into a Z-Wave network.
The document summarizes the VertX V200 input monitor interface, which connects up to 16 supervised input circuits for alarm systems. It reports the status of input points and connects to the V1000 interface over RS-485. The V200 has flash memory for firmware updates, LED indicators, terminal connectors, and an enclosure that protects its components.
1) The document describes the Digital Contact Controller (DCC) made by ATLab, a Korean company located in Yongin-shi.
2) The DCC uses a fully digital architecture for capacitive touch sensing and is used in applications such as portable electronics, home electronics, and office equipment.
3) Key features of the DCC include low power consumption, fast response time, water resistance, ESD durability, and interference suppression between multiple touch points.
The 2351E photoelectric smoke detector is part of Honeywell's Series 300 range of conventional detectors. It features an ASIC chip and optical chamber for accurate fire detection with resilience to environmental factors. It has automatic drift compensation to maintain a consistent alarm threshold between services. The detector's sensitivity can be optimized through three preset alarm levels and programmed via a remote handheld unit, which also provides maintenance information like chamber contamination. It is compatible with Series 100 detector bases and includes a bi-color LED status indicator.
Manual del dispositivo regulador oculto Z-Wave de Widom que permite variar la intensidad de una lámpara, o la velocidad de un motor (como por ejemplo un ventilador).
The document describes the MCOM micro single channel output unit, which is a small, soft-addressed interface unit that can be used to switch low-voltage circuits like HVAC or fire doors. It has an integral short circuit isolator, compact size, and connects to Menvier intelligent fire panels. Variants include the MCOM-R, which provides a 5-second reset pulse, and MCOM-S, which is identified as a sounder.
The document summarizes the Cooper CF1000VDS range of intelligent addressable fire alarm control panels. Key points:
- The CF1000VDS range includes 1-loop and 2-loop control panels approved to EN54 standards.
- The panels offer up to 200 addresses per loop, network capability up to 126 panels, and features like soft addressing and a touchscreen user interface.
- Benefits include simple operation, flexible network and programming capabilities, and compatibility with a range of accessories.
The MSI850 spur isolator unit allows a spur of intelligent addressable devices to connect to the main loop. It simplifies installing remote parts of buildings or simple extensions. It has integral short circuit isolators for the loop and spur, and automatically controls addressing. It is quick and easy to install, and reduces costs by using existing wiring without needing external isolators.
The Honeywell 5806W3 is a wireless photoelectric smoke detector that sends alarm, tamper, and low battery signals to a wireless receiver. It uses advanced algorithms and a microprocessor to reduce false alarms from dust or contaminants. A removable cover allows technicians to easily clean the detector chamber without disassembling the unit. The wireless design makes installation simple without running wires.
The document describes a conventional fire alarm panel that includes:
- Microprocessor control and SMT electronics compliant with various standards
- Detection of up to 25 fire detectors and call points on one zone
- Two output control points to control indicators like sounders and strobes
- Standby batteries, fault and alarm indicators, and short circuit detection
- Simple installation and operation via a key switch
The document describes the R6000 range of intelligent addressable rack mounted control panels from Cooper Lighting and Safety. The R6000 consists of modular plug-in components that can be configured for functions like fire detection, alarm signaling, and plant control. The system allows up to 126 panels to be networked together and provides flexible programming and expansion capabilities. The floor rack unit houses the R6000 control panels and is constructed of mild steel.
The EC700 Modbus Gateway allows integration between a LonWorks fire system and a third party Modbus BMS system. It has a robust hardware platform with a high performance CPU and UART for fast communications. It features 3 communication ports for LonWorks, serial, and programming connections. The serial port supports either RS232 or RS485 communications. It provides address mapping between LonWorks and Modbus variables to allow data sharing between the two systems.
This document provides information on the Honeywell 5808W3 photoelectric smoke/heat detector with a built-in wireless transmitter. The detector uses a lithium battery and transmits alarm, tamper, and low battery signals wirelessly to a receiver. It has improved RF range and algorithms that minimize nuisance alarms. Additional features include a fixed temperature thermal sensor, easy installation base, and status indicators. The detector is suitable for both residential and commercial applications.
The CF3000PRG passive repeater panel displays system information from an intelligent addressable fire system. It has a backlit LCD display and LED indicators. It can be programmed to be fully passive for display only or semi-passive for limited control functions like silencing alarms. When connected to a loop or network, it will show the status of the host panel and any other panels that activate. Up to 20 repeaters can be connected to a single loop or network to provide status information across the system.
The IS215T motion sensor is a passive infrared sensor with a white housing that offers quality motion detection for basic security applications. It has features like adjustable sensitivity, look-down detection zones, white light immunity, and a tamper-proof design. The sensor can be mounted on walls or corners and has an attractive sleek design to blend in with any room décor. It is designed for residential and light commercial security applications.
The InnovairFlex D4120 duct smoke detector features a flexible housing that fits both square and rectangular ducts. It operates in air velocities from 100 to 4,000 feet per minute and temperatures from -4°F to 158°F with 0-95% humidity. The plug-in sensor head offers improved false alarm immunity and maintenance. Up to 50 detectors can be interconnected to isolate the fire source location.
App095 en acquisition-internal-diameter-tubesISATECK
The document describes a capacitive displacement sensor system for measuring the internal diameter of pipes. The system uses a "Molch" device containing two pairs of sensors that is pushed or lowered into the pipe. As it moves through the pipe, the sensors record the diameter at regular intervals. The recorded diameter measurements and positions are analyzed to generate a profile of the pipe's internal diameter over its length. This profile allows operators to identify any areas where the diameter is outside tolerances, such as locations of pipe damage or wear, so those sections can be replaced if needed without having to replace the entire pipe unnecessarily. The system provides a non-destructive testing method that is fast, accurate to 0.1mm, rugged for industrial use
This document summarizes intelligent addressable reflective beam detectors from Cooper. The MAB50R has a range of up to 50 meters while the MAB100R has a range of 50-100 meters. Both connect to the loop of Cooper intelligent fire systems and require no separate power supply. They replace individual point detectors in large open areas through their simple installation and single maintenance point.
This document describes intelligent addressable reflective beam detectors that can detect smoke or fire across large open areas. The MAB50R has a range of up to 50 meters, while the MAB100R has a range of 50-100 meters. Both connect to the fire alarm control panel via a loop circuit and do not require a separate power supply. They have three operating modes for alignment and detection. Optional mounting brackets are available to facilitate installation.
The MTETM Series Encoders are compact linear encoders that offer high performance in small spaces. They have a miniature sensor, use little power, and install easily without tools by mounting directly onto a narrow adhesive-backed tape scale. The encoders provide high resolution, accuracy, and a status LED to indicate health.
ZVxPlus Product Note: Nonlinear Extension Kit for R&S VNANMDG NV
The document describes an extension kit called the NM310 that adds nonlinear measurement capabilities to Rohde & Schwarz Vector Network Analyzers (VNAs) like the ZVA and ZVT models. The kit allows characterization of RF/HF components from 20 MHz to 24 GHz by measuring their harmonic behavior and response in both the time and frequency domains. Key benefits include full harmonic characterization, measurement of voltages and currents under realistic non-50 ohm conditions, and improved transistor modeling from small-signal to large-signal operation. The NM310 kit works with ICE software to enable complex nonlinear measurements and characterization of devices like diodes, transistors, and amplifiers.
App001 en monitoring-commutator-electric-motorsISATECK
This document discusses using eddy-current displacement sensors (eddyNCDT) to monitor the condition of commutators in electric motors. It provides three key points:
1) EddyNCDT sensors offer non-contact monitoring of commutators, are not subject to wear, and do not affect the commutator. This allows continuous monitoring, especially for hard-to-access motors.
2) A basic eddyNCDT system comprises a sensor, cable, and electronics. More complex systems use special signal processing.
3) EddyNCDT sensors are precise, fast, stable over temperature fluctuations, and compatible with electric motors. They can monitor commutator
The ZXSe Range Data Sheet summarizes an analogue addressable fire alarm control panel system. It supports five detection protocols and can be expanded with additional devices, loop cards, printers, or networked panels. Key features include multi-protocol support, modular expandability, intuitive user interface, and networking of up to 99 panels to manage over 60,000 devices.
Micro e systems_mercuryii6000v_datasheetElectromate
The document summarizes the features and specifications of the Mercury II 6000V encoder system. Key points include:
- The system provides high resolution from 5μm to 1.22nm and high accuracy with linear or rotary glass scales.
- It has a small sensor size, low power consumption, broad alignment tolerances, and software for setup and monitoring.
- The system offers versatility in using the same sensor for linear or rotary applications, and can operate at speeds up to 5m/s at high resolutions.
- Optional features include different scale lengths and diameters, as well as software for additional monitoring and setup capabilities.
The document summarizes the specifications and features of the Texecom Odyssey 3 external sounder and strobe series. Key features include a 115dB volume, IP65 sealed electronics, selectable SAB/SCB mode, screw, lid, and wall tamper protection, twin alternating LEDs, and revolutionary screw retention system. It is competitively priced, easy to install, and provides uncompromising performance for professional security installations.
The document describes the TOA VM-3000 series integrated voice evacuation system. It is an EN 54 compliant system that combines emergency voice alarm and public address functions. Key features include fully digital audio processing and control, built-in voice messages, monitoring of speaker lines, and support for paging, background music, and microphone inputs. The system is suitable for small to medium venues and provides emergency evacuation and general announcement capabilities.
The document describes the TOA VM-3000 series integrated voice evacuation system. The VM-3000 series provides both emergency evacuation functions and general public address/paging functions. It is EN 54 certified and ideal for small to medium venues. The system has integrated amplifiers, supports up to 60 speaker zones, and can be configured via software.
This document provides installation instructions for installing a SV-200MA Surveillance Board in VM-2120 or VM-2240 amplifiers. The SV-200MA adds monitoring, zone control, and backup amplifier functions. It consists of an SV-200M board and SV extension board. The 10 step installation process includes setting jumpers, connecting cables between the boards, mounting the surveillance board, and replacing the amplifier cover.
The document describes TOA's SC Series Paging Horn Speakers. It includes specifications for 6 models that are rated at either 10W, 15W, or 30W and are designed for both indoor and outdoor use. The speakers feature weatherproof stainless steel brackets, powder coated horns, and input impedance selector switches on high-impedance models. Diagrams show the speakers' frequency responses, beamwidths, directivity factors, and polar responses.
The document describes TOA's SC Series Paging Horn Speakers. It includes specifications for 6 models that are rated at either 10W, 15W, or 30W and are designed for both indoor and outdoor use. The speakers feature weatherproof stainless steel brackets, powder coated horns, and input impedance selector switches on high-impedance models. Diagrams show the speakers' frequency responses, beamwidths, directivity factors, and polar responses.
The document describes TOA's CS-154 and CS-304 outdoor wide-range speakers. The speakers use wide-range horns to provide high quality background music or paging announcements over a wide area. They are designed for outdoor use and have weatherproof enclosures that can withstand demanding environmental conditions. The speakers have adjustable impedance settings and provide high output with increased efficiency through the use of a horn and cone speaker combination.
The document describes the TOA BS-678 wall mount speaker system. It is a double-cone speaker with a wooden cabinet and stylish, compact design. It produces high quality sound for background music and announcements. Key features include an adjustable input impedance selector, push-in connector for easy wiring, and horizontal or vertical mounting orientation. Specifications include a frequency response of 150-20,000Hz, 6W or 3W power handling, and an off-white finish.
The document describes the TOA BS-633A/633AT wall mount speaker systems. The BS-633A is a basic 5" cone speaker with a transformer allowing multiple power taps. The BS-633AT includes an additional built-in attenuator, allowing connection to 2-wire and 3-wire speaker systems. Both have a compact ABS resin enclosure and push-in terminal for easy installation. Key specifications include a frequency response of 120-15,000Hz, 91dB sensitivity, and multiple power taps for 100V and 70V speaker lines.
This document summarizes an LB1-UW06-Fx cabinet loudspeaker from Bosch. It is a 6W loudspeaker intended for indoor use. It has mounting brackets for wall or ceiling mounting. It is constructed of MDF and has a durable vinyl or cloth covering available in white or black. It provides good speech intelligibility and background music reproduction.
This document summarizes a 6W loudspeaker for indoor use. It has good speech intelligibility and background music reproduction. The loudspeaker has an MDF construction with mounting brackets for wall or ceiling installation. It complies with international safety regulations and certifications.
The LA1-UW36-x is a 36W column loudspeaker for indoor use where directivity is important. It has high sensitivity and provides good speech intelligibility and background music reproduction. It has a swivel wall mounting bracket and is available in black or white. It uses four dual cone drivers and a durable MDF enclosure for reliability under extreme conditions.
The LA1-UW24-x is a 24W column loudspeaker for indoor use where directivity is important. It has good speech intelligibility and background music reproduction. It comes with a swivel wall-mounting bracket and is available in black or white. It has four high-sensitivity drivers and can be powered at full, half, or quarter power via a terminal block on the rear.
This document provides specifications for a BGT 4139TS video camera model. It includes details on the camera's image sensor, resolution, lenses, operational features like auto day/night mode and infrared LEDs, environmental tolerances, electrical requirements, mechanics including dimensions and weight, and manufacturer. The camera has a 1/3" CCD sensor, 600TVL resolution, auto settings, infrared for night vision up to 20 meters, and an IP66-rated casing.
This document provides specifications for a BGT 5504A camera model, including details about its video capabilities, lens, operational features, environmental tolerances, electrical requirements, and dimensions. It has a 1/4" CCD image sensor, 420TVL resolution, auto day/night mode, 15m infrared range, and measures 92mm diameter by 80mm, weighing 190g.
This data sheet provides specifications for the BGT 5140A video camera, including its CCD image sensor, PAL/NTSC compatibility, effective pixel count, 420TVL horizontal resolution, low light performance down to 0.5 lux, auto day/night functionality, 3.6mm fixed focal length lens, operating temperature range of -10°C to 50°C, power requirements of 12V 150mA with a 12V 1A adapter, and compact dimensions of 60x90x190g.
This data sheet provides specifications for a BGT 9120TS security camera model. It lists technical details such as the CCD image sensor and effective pixel resolution, as well as operational features including auto day/night mode, backlight compensation, and automatic gain control. Environmental specifications note an operating temperature range of -10°C to 50°C and IP66 protection rating. The camera is powered by a 12V 370mA power supply and has dimensions of 266x97x63mm.
This data sheet provides specifications for a BGT 9119AS video camera model. It has a 1/3 inch Sony CCD image sensor that can capture video in PAL or NTSC formats with effective pixel counts of 752x582 or 768x494 respectively. The camera has a 3.6/6mm fixed lens, auto day/night functionality, and can function in temperatures from -10 to 50 degrees Celsius. It is powered by a 12V 1A adapter and has IP67 protection against dust and water.
This document provides specifications for the BGT 720TOS security camera model, including details about its video capabilities, lens, operational features, environmental tolerances, electrical requirements, and dimensions. Key specs include a 1/3" Sony CCD image sensor, 600TVL horizontal resolution, auto day/night functionality, auto electronic shutter speed range of 1/50-1/100,000 sec for PAL and 1/60-1/100,000 sec for NTSC, operating temperature range of -10°C to +50°C, input voltage of DC12V/150mA, and compact dimensions of 102*55*40mm.
This document provides specifications for the BGT 5221AS video camera model. It includes details about the camera's image sensor, resolution, lenses, video output, day/night functionality, electrical requirements, and dimensions. Key features noted are a 1/3" Sony CCD image sensor, 480TVL horizontal resolution, auto day/night mode, infrared LEDs for night vision up to 10 meters, and DC12V 400mA power input. The camera measures 90*108*108mm and weighs 300g.
1. cfs0018_UK_R1_menvier-data-sheets_Layout 1 04/08/2011 12:06 Page 97
Intelligent Addressable Product Range
Micro Zone Monitor Unit MIU872
MIU872 micro zone monitor unit
Overview Features
An extensive range of micro interfaces are available • Quick and simple to install
to support the Menvier range of control panels, • Accepts a zone of Menvier
conventional detector heads
providing solutions for most design requirements.
and callpoints (detectors must
be connected via the Cooper
The MIU872 is a single zone input, soft addressed,
CDBB300 mounting base)
micro interface, incorporating integral short circuit
• Only takes a single address
isolators.
• Input monitored for open and
short ground trouble
It is fully compatible with the current range of Menvier
• Active end of line monitoring
intelligent addressable fire detection panels.
• Built in short circuit isolator
It is suitable for interfacing a zone of up to 20
conventional Menvier detectors onto a Menvier Benefits
intelligent addressable control panel.
• Plug and play no hard
It will operate with any Menvier conventional detector addressing required
in configuration with a schottky diode type base. • Easy to expand a system using
existing wiring
• No external short circuit
isolator required
2. cfs0018_UK_R1_menvier-data-sheets_Layout 1 04/08/2011 12:06 Page 98
Intelligent Addressable Micro Zone Monitor Unit - MIU872
Dimensions Technical Specification
H (mm) W (mm) D (mm) Code MIU872
65 35 18.5 Description Micro zone monitor unit
Standards EN54 Pt17 & Pt18
Specification
D
Operating Voltage 18V dc to 30V dc
Quiescent Current 2.6mA (nom)
H
Load With 20 Detectors,
W
and Unlimited Callpoints 3.2mA (nom)
Alarm Load With 20 Detectors,
and Unlimited Callpoints 8.0mA (nom)
Mounting Details Detector Zone
Detectors per Zone 20 (max)
End of Line Monitor Active end of line unit - EOLM-1
Fire Input Trigger Resistance 680Ω (nom)
Short Circuit Fault
Threshold Resistance 100Ω (max)
Open Circuit Fault
22mm
Threshold Resistance 39KΩ (min)
Environmental
Operating Temperature -10ºC to +60ºC
Humidity (non condensing) 0 to 95% RH
Physical
Construction PC/ABS
Dimensions (H x W x D) 65mm x 35mm x 18.5mm
Weight 0.28kg
37.5mm
Ingress Protection IP40
Compatibility
Suitable for use with Menvier intelligent addressable fire systems
Installation
1. Suitable for use with any Menvier conventional detector.
2. Connections suitable for single strand fireproof cable up.
to 2.5mm2.
3. Loop and output cable screen must be connected to
interface earth terminals.
Note: No addressing of the interface is required
(see control panel operation for details)
Standard Connections
EOLM-1
IN+
IN-
EARTH LOOP IN
maximum 20 Cooper conventional detectors INPUT
LOOP OUT
Note: The MIU872 accepts a zone of Menvier Product Codes
conventional detector heads (detectors must
be connected via the Cooper CDBB300 Code Description
mounting base) MIU872 Micro zone monitor unit
Cooper Lighting and Safety Ltd, Wheatley Hall Road, Doncaster, South Yorkshire, DN2 4NB. UK.
T: +44 (0) 1302 303350 l F: +44 (0) 1302 303332 l E: techsupport@cooperfire.com l W: www.cooperfire.com