SlideShare a Scribd company logo
1 of 8
Download to read offline
Measuring
                         technological innovations
                         for leak detection in
                         drinking water systems
Combi leak detector

                                               FFT high performance                       Wireless sound
                                                           correlator                     logging system




  EXCLUSIVE
     at Trotec !




Pressure data                      Trace gas                            Pulse wave
logger                             sensors                              generator




                      Professional solutions for zone measurements, prelocation and pinpoint detection
                      Water loss reduction Measuring data documentation
Phone +49 2452 962-400                            info@trotec.com
                                                                                                                                   Fax +49 2452 962-200                              www.trotec.com




                        BENEFITS IN PRACTICE:

                        Acoustic and trace gas leak detection
                                                                        LD6000 combi-detector
                        in only one device

                        High-resolution colour graphic display
                                                                        Leak detection and acoustic pipe location
                        with touchscreen functions

                        The only one of its kind in its                  EXCLUSIVE
                        class. State-of-the-art smart                       at Trotec !
                        function for even faster pinpoint leak
                        detection (patent filed)

                        Numerous preprogrammed common
                        applications for quick access

                        All filters and parameters can
                        be configured individually

                        Pipe detection mode

                        Complies with all guidelines govern-
                        ing according to VBG 121 (when used
                        with original headphones) (VBG - trade
                        association safety regulations)
                        Highly-sensitive, high-quality,
                        robust precision microphone
                        made in Germany




                                                                        The LD6000 cutting-edge                              Whether you need it for laying out pipes    Long-term measurements
                                                                         leak detection device sets                          or to narrow down the search or pinpoint    In order to be
                                                                           new standards in the field                        a leak – the highly-sophisticated LD6000    able to pinpoint
                                                                                                                             and the high-quality microphone, which      the leak exact -
                                                                           of leak detection…                                both carry the hallmarks of a product       ly, an onboard
                                                                        W Acoustic pinpoint                                  made in Germany, allow you to determine     sound logger can be activated to log
                                                                            leak detection                                   even the tiniest of leaks and display the   measurements carried out over a period
                                                                        W Pipe detection                                     signal before it is processed.              of up to 60 minutes, which can then
                                                                        W Long-term measuring                                                                            be used to determine or rule out any
                                                                            with logging function                            Overview of the functions                   leaks with the help of the recorded
                                                                                                                                                                         measurement curve.
                                                                        W Trace gas detection                                F&L mode – hear and see leaks
                                                                        W All in only one device !                                                                       Pipe detection mode
                                                                                                                             As many as ten measuring cycles are dis-
                                                                                                                             played either as a number or a two-seg-     This mode is designed especially to de-
                                                                                                                             ment colour bar – one for frequency and     tectplastic pipes which are subjected
                                                                                                                             one for volume. The leak is there where     to ultrasound via the LD-PULS impulse
                                                                                                                             the two segments are at their steepest.     generator.

                                                                         y
                                                                                                                             Smart mode                                  Trace gas detection
                                 r
                                                                                                                             The state-of-the-art smart function
                                                                                                                                                                         Trace gas can be used in combination
                                                                                                                             is the only one of its kind in its
                                                                                                                                                                         with the LD6000 H2 hydrogen sensor
                                                                                                     t                       class and has been filed for patent
                                                                                                                                                                         to carry out quick and effective leak
                                                                                                                             – the smarter way to find leaks.
                                                                        w                                                                                                detection in pipe networks and pipe
                                                                                                                             Complex algorithmic calculations which      systems in houses.
                                                                                                                             are carried out unseen in the heart of
                                                                                                                             the device provide you with a clear         The trace gas used is hydrogen, which
                           e                                                                                                 view of what you need to see: the exact     due to its specific structure is able to
                                                                                                           Grafik © Trotec®




                                                                                                                             position of the leak, revealed to you by    penetrate and pass through various ma-
                                                                                                                             means of a bar indicator which rises        terials like soil, concrete, tiles etc. easily
                                                                                                                             sharply where the leak is. It doesn’t get   before then being detected by the sensor
                                                                                                                                                                         at the places where it escapes through
TRT-KAT-LEDE-WM-06-EN




                                                                                                                             any easier than that!
                        The innovative, state-of-the-art LD6000 combi detector is suitable for a variety                                                                 the system that is being inspected.
                        of different application and allows you to detect leaks using both the acoustic                                                                  The LD6000 is able to show the exact
                        and trace gas method with only a single device.                                                                                                  concentration of hydrogen. The thresh-
                        G Acoustic pinpoint leak detection with geophone h Detection and pipe laying,                                                                    olds can be individually configured and
                        also for plastic pipes j acoustic body sound measurement. k trace gas leak
                                                                                                                                                                         an acoustic and optical signal warns
                        detection in drinking water systems. l leak detection and leak tightness
                        inspection of pipe systems in houses and industrial pipe networks.                                                                               the user when these thresholds have
                                                                                                                                                                         been exceeded.

2
LEAK DETECTION




The principle of acoustic                                                                                                                Standard scope of delivery:
                                                                i                     e
leak detection                                                                                                                           • LD6000 measuring device .
                                                                                                                                         • LD K – sound blocking headphones e




                                                                                                                                                                                        Trotec
Water which escapes from high-pres-                                                                                                      • LD6000 BM – universal microphone
sure pipes at high speed causes fric-                                                                                                      with magnet adapter r
tion which in turn can be picked up                                                                                                      • LD6000 DA – tripod adapter t
in the form of sound waves.
                                                                                                                       r                 • LD6000 VL – stick extension with tip y
The pipes themselves start to oscil-                                                                                                     • LD6000 TG – shoulder strap u
late. The sound that is generated is




                                                                                                                                                                                        Telemetry
                                                                y                                                                        • PC connecting cable
transmitted through the pipes and
                                                                                                          w             o                • LD6000 carry case
can be transformed into audible
sound with a body sound micro-                                                                                                           Optionally available accessories:
phone at a distant contact point                                                                                                         • LD6000 BMW –
(valve, hydrant, armature).                                                                                                                wind protected ground microphone




                                                                                                                                                                                        Planning and survey
                                                                                                                t                          (with dead-man’s button) Y
In addition the water leaking out                                                           u
through the crack or hole in the pipe                                                                                                    • LD6000 VK – connecting cable
generates sound which is carried                                                                                                         • LD6000 DM – tripod magnet for
through the ground to the surface.                                                                                                         LD6000 BMW ground microphone o
                                                         p                                                                 a             • LD6000 H2 –
This sound can be picked up by a
geophone and transformed into au-                                                                                                          hydrogen hand sensor p
dible sound.                                                                                                                             • LD6000 H2 –
                                                                                                                                           hydrogen ground sensor O




                                                                                                                                                                                        Temperature
Technical data           LD6000                                                             LD-PULS pulse wave generator
Article no.              3.110.008.010
                                                                                            This impulse generator is excellently-
                         Acoustic leak detection (F & V, Smart, long-term measuring),
Operating mode                                                                              suited for use with the LD6000 meas-
                         pipe detection and trace gas leak detection
                                                                                            uring device.
                         Measuring modes for minimum level, averaged level,
                         pulse wave measurements, simultaneous F&V analysis,                The LD-PULS is not affected by electric




                                                                                                                                                                                        Velocity
                         logging function, automatic functions for setting filter            cables and can detect non-metallic wa-
Measuring and
                         frequencies and sensor sensitivity, memory preference              ter pipes up to a depth of 2 metres
device functions
                         for manual filter settings, sound level overmodulation
                         protection, trace gas detection with concentration-                without having to close off any part of
                         dependent signal (optic and acoustic)                              the network or system.
Controls                 Either via touchscreen, keys or control dial                       The LD-PULS generates up to 60 oscil-
Amplification             120 dB low noise factor                                            lations per minute which under




                                                                                                                                                                                        Moisture
Input impedance          1M Ω                                                               favourable conditions can spread out
                         Up to 256 can be configured individually                            as far as 600 m into the pipe before be-
Filter                                                                                      ing detected by a ground microphone.
                         (for stick sensor and ground microphone)
Display                  Colour LCD (automatic illumination), 480 x 272 pixels              This means that this method can be
Battery check            Via micro-controller                                               used to compile, complete or check
                                                                                            plans and pipe layouts or networks.




                                                                                                                                                                                        Multi-function
Output impedance         ≤ 10 Ω
Power supply             4 x batteries type LR14 C 1.5 V
Operating time           up to 14 h in non-stop operation, up to 40 h in normal operation
                         Bayonet nut connector (microphone / sensor),                                                                    Standard scope of delivery:
Connections
                         6.3 mm jack plug (headphones)
                                                                                                                                         • LD-PULS – pulse wave generator
Protection class         IP54
                                                                                                                                                                                        Tracing and detection
                                                                                                                                           built into sturdy case with integrated
Housing                  Aluminium, powder-coated                                                                                          rechargeable battery
Temperature conditions   During operation: -5 °C to +55 °C; Storage: -25 °C to +65 °C                                                    • Separate power supply for LD-PULS
Dimensions approx.       L 210 x W 160 x H 60 mm                                                                                         Optionally available accessories:
Weight approx.           1,050 g                                                                                                         • LD-PULS repair set containing
                                                                                                                                           an Allen key and 4 valves
Technical data           LD6000 H2 hydrogen hand and ground sensor
                                                                                                                                                                                    Optical inspection




Article no.                       3.110.008.111                   3.110.008.015
                                                                                                                                                                                         systems




Response sensitivity                                1 ppm H₂                                Technical data              LD-PULS
Measuring range                          10 ppm H₂ to 20,000 ppm H₂                         Article no.                 3.110.008.012
Resolution                                          1 ppm H₂                                Minimum pressure            2 bar (29 psi) (minimum pressure of the service pipes)
Reaction time                                         0.5 s                                 Operating time              Approx. 12 hours
                         Hand sensor with flexible swan-neck (length 50 cm)                  Pulse sequence              Approx. 60 per minute
                                                                                                                                                                                        Leak detection




                         and 160 cm connecting cable for LD6000
Design                                                                                      Connection                  1-inch GEKA high pressure coupling
                         Ground sensor with two-part stick microphone
                         (length approx.1 m) and rubber sleeve, approx. 200 cm                                          Internal battery (rechargeable)
                                                                                            Power supply
                         connecting cable for LD6000                                                                    or 230V AC
Temperature conditions   During operation: -10 °C to +60 °C; Storage -20 °C to +60 °C       Weight                      4.2 kg


                                                                                                                                                                                        3
Phone +49 2452 962-400                           info@trotec.com
                                                                                                                 Fax +49 2452 962-200                             www.trotec.com




                        BENEFITS IN PRACTICE:

                        LD5L and LD5LR wireless data loggers:
                                                                Sound and pressure data logger
                        Localisation of leaks                   Mobile zone monitoring of drinking water systems
                        using long-term monitoring

                        Wireless measuring data transfer        Leaks in drinking water systems do not only endanger
                        Quick logger data read out              the quality of your water supply – precious water seeps
                        from moving vehicles                    out uncontrollably resulting in losses worth hundreds
                        Extremely economical                    or thousands of pounds...

                        Sound level detection,
                                                                The mobile wireless monitoring
                        analysis and logging
                                                                system in the Trotec MultiMeasure
                        Easy to use                             Professional Series enables you to
                                                                carry out reliable acoustic zone
                        Including LogControl user               measurements in drinking water
                        software, GIS compatible
                                                                systems in order to detect possible
                                                                cracks, fissures and leaks.
                                                                A magnetic base and optionally available
                                                                mounts and brackets allow you to posi-
                                                                tion your wireless data logger in a va-
                                                                riety of different positions to measure
                                                                the sound levels in the pipe system or
                                                                network.
                        BENEFITS IN PRACTICE:
                                                                In addition, a model with a hydrophone
                        LD5DL pressure data logger :            can be used for measuring operations
                                                                that are carried out with the medium
                        Designed specifically for monitoring    water – ideal for plastic pipes or pipe
                        pressure in water supplies.             networks that cover greater distances.
                        Robust, waterproof– no prod contacts    The wireless data loggers detect, analyse
                                                                and log sound levels during the night
                        Foil keys for on-site programming
                                                                when less water flows through the sys-      All logging data from the LD5LR receiver
                        Extremely large memory for more         tems and transmits all the measuring        can be transferred to a PC via the USB
                        than 240,000 measuring values           data up to 12 times a minute.               interface for further analysis and docu-
                                                                                                            mentation.
                        Very high measuring sensitivity         All measuring data can be picked up
                                                                and logged from a passing vehicle with      The LogControl data bank
                        Infrared / USB data transfer            the use of a mobile LD5LR receiver.         supported software included
                        and infrared / GSM (optional)
                                                                The leak status and further measuring       in the scope of delivery is
                        Battery life for approx.                data are displayed directly on the                       GIS compatible and pro-        signed and individual regions can be
                        10,000,000 measuring values             LD5LR’s easy-to-read display.                            vides graphic supported        created to establish a borderline be-
                                                                                                                         functions for analysis and     tween different pressure zones.
                                                                                                      e                  management.
                                                                                                                         Individual pipe plans can      LD5LR standard scope of delivery:
                                                                                                                         be transformed into maps,      • LD5LR receiver (read out device) w
                                                                                                                         for example; individual log-   • six LD5L data loggers with magnet
                                                                  y                                                      ger locations and meas-          base and onboard antenna e
                                                                                                                         urement series can be as-      • Switching magnet r
                                                                                           r                                                            • USB cable
                                                                                                                                                        • LD5L carry case
                                                                                                                                                        • LogControl software

                                                                                                                                                        Optionally available accessories:
                                                                                                                                                        • LD5L WA – angle adapter
                                                                                                                                                          for wireless data logger t
                                                                                    t                                                                   • LD5L HYDRO – acoustic wireless
                                                                                                                                                          data logger with hydrophone
TRT-KAT-FDAL-WM-05-EN




                                                                                                                                                          sensor (hydrophone logger) y
                                                                                                                                                        • LD5L HYDRO UF – adapter for
                                                                                                                         w                                hydrophone logger for assembly
                                                                                                                                                          in DIN hydrant claw, ½-inch inner
                                                                                                                                                          thread with vent, for assembly
                                                                                                                                                          with key valve




4
LEAK DETECTION




                                            The measuring values logged by the wire-                      Technical data              LD5LR receiver
                                                    less data logger are transmitted                      Article no.                 3.110.008.110
                                                        automatically to the passing




                                                                                                                                                                                                             Trotec
                                                            vehicle and recorded by                                                   Statistic minimum level of the previous night,
                                                                  the L5LR receiver.                                                  level progress of the past 14 days, quietest and
                                                                                                          Description
                                                                                                                                      loudest level during the last 10 minutes, selection
                                                                                                                                      time, leak status, amplifier, logger serial number
                                                                                                          Memory                      Automatic (the last 14 measuring cycles)
                                                                                                          Memory capacity             Up to 100 loggers (optionally 2,000 loggers)




                                                                                                                                                                                                             Telemetry
                                                                                                          Display                     LCD backlight, 128 x 64 pixels
                                                                                                          Transmitter frequency       433 MHz (other frequencies on request)

                           The measuring                                                                  Power supply                4 x type LR03 AAA 1.5 V batteries




                                                                                       Grafik © Trotec®
                   engineer can calibrate a leak                                                          Interface                   USB
           directly on site with a correlator or a sound




                                                                                                                                                                                                             Planning and survey
                                                                                                          Temperature range           -15 °C to +55 °C
         locator by using the direct optical leak status
    indicator on the display of the receiver if required.                                                 Dimensions                  200 x 95 x 30 mm, Weight 350 g

Technical data
Article no.
                         LD5L wireless data logger
                         3.110.008.120
                                                                                                         LD5DL pressure data logger
                                                                                                                                                           The LD5DL pressure data logger has
                         permanent (07:00am to 07:00pm 12x per minute;
Data transfer                                                                                                                                              been designed especially for monitoring
                         07:00pm to 07:00am : 1x per minute.)
                                                                                                                                                           pressure in water supplies. Its internal
                         Statistic minimum level of the previous night, level progress




                                                                                                                                                                                                             Temperature
                         of the past 14 days, quietest level (AL) and loudest level (AH)
                                                                                                                                                           vent makes it ideally suited for precise
Data logging                                                                                                                                               pressure progress measurements for
                         during the last 10 minutes, amplifier, quality of the measure-
                         ment (rain, wind etc.), logger serial number logger location                                                                      pipe networks and tempering water and
Amplification             200,000 times                                                                                                                     for pressure sampling.
Recording period         2:00 o’clock to 4 o‘clock                                                                                                         The high sampling rate of up to 10
Transmitting power       10 mW                                                                                                                             measurements per second enables the
Transmitter frequency    433 MHz (other frequencies on request)                                                                                            logger to detect even short pressure




                                                                                                                                                                                                             Velocity
                                                                                                                                                           surges reliably before logging them.
Memory capacity          14-day ring memory
Protection class         IP68                                                                                                                              The LD5DL can store up to 240,000
                         Nitrogen-filled housing 1.5 bar,                                                                                                   measuring values and present them
Type of housing                                                                                                                                            on its easy-to-read display. The logger
                         condensate protected circuit board
Sensor                   piezo ceramic                                                                                                                     is operated via the USB interface of
                                                                                                                                                           your PC or a GSM module at the logger




                                                                                                                                                                                                             Moisture
Temperature range        -15 °C to +55 °C
                                                                                                                                                           itself. Measurements with the LD5DL
Operating time           5 years (without having to change the battery)                                                                                    can be easily carried out from as little
                         Dimensions ø 40 ⁄ 44 mm ⁄ Height 110 mm; onboard antenna                                                                          as one second to several months.
Dimensions
                         (english construction); Weight approx. 450 g
                                                                                                         LD5DL basic package 1 *                           The data stored in the pressure data
Technical data           LD5DL pressure data logger                                                      • LD5DL – pressure logger with ½-                 logger can be read out via the IR-USB




                                                                                                                                                                                                             Multi-function
Article no.              3.110.008.130                                                                     inch outer thread, 0 to 20 bar                  interface and transferred to your PC
                                                                                                         • LogControl DL software                          and analysed using the LogControl DL
                         Water pressure sensor, (optional temperature ⁄ air pressure
Sensors (internal)                                                                                       LD5DL basic package 2 *                           software included in the scope of delivery.
                         sensor for altitude determination)
Pressure measuring       Standard sensor 20 bar; further pressure ranges 1 ⁄ 1.6 ⁄ 2.5 ⁄                 • LD5DL UF pressure logger with ½-                                            The data bank
ranges                   4 ⁄ 6 ⁄ 10 ⁄ 16 ⁄ 25 bar, possible up to max. 50 bar                              inch outer thread and below ground
                                                                                                           hydrant claw, mounted (in compli-                                           supported soft-
Measuring cell           Long-term stable, piezo resistive, temperature compensated                                                                                                    ware enables
                                                                                                                                                                                                             Tracing and detection
                                                                                                           ance with DIN), 0 to 20 bar
Temperature range        Up to 70 °C                                                                     • Software LogControl DL                                                      you to process
Measuring accuracy       < 1 % from final value at 20 °C                                                  • Assembly aid with hydrant base DIN                                          single meas-
                         ± 0.005 % (over the whole measuring range),                                     LD5DL basic package 3 * **
                                                                                                                                                           urements graphically or transfer various
Resolution                                                                                                                                                 measuring curves. There is also an export
                         for example 0.5 mbar at 10 bar measuring range                                  • LD5DL OF pressure logger with ½-
                         1 s to 24 h (can be configured individually),                                      inch outer thread and above ground              function available which allows you to
Measuring interval
                         0.1 s to 1 s (shock pressure recognition)                                         hydrant claw (3-inch thread), mounted           archive your data flexibly.
                         exact quartz measurement with time and date, starting time                        (in compliance with DIN), 0 to 20 bar
                                                                                                                                                                                                         Optical inspection




Real-time clock                                                                                                                                            Optionally available accessories
                         of the measuring data logging can be selected individually                      • LogControl DL software
                                                                                                                                                                                                              systems




                                                                                                                                                           for LD5DL pressure loggers:
Memory capacity          > 240,000 measuring values                                                         Minimum required features:
                         buffered RAM (measuring value conservation                                      * 1 x LD5DL IR-USB interface (read out device)    • LD5DL IR-USB interface – read out
Memory type                                                                                              ** adapter für B-connection incl. B-coupler         device with for the LD5DL with USB
                         during battery change)
                                                                                                                                                             interface
Interface                Infrared ⁄ USB data transfer (infrared ⁄ GSM optional)
                                                                                                                                                           • LD5DL 20 up to max. 300 bar
Display                  LCD
                                                                                                                                                           • External GSM module for LD5DL
                                                                                                                                                                                                             Leak detection




                         Lithium battery 3.6 V ⁄ 8.5 AH type AA, battery life                                                                              • Adapter for B-connection incl.
Power supply
                         approx. 10,000,000 measuring values
                                                                                                                                                             B-coupler
Type of housing          Stainless steel ⁄ aluminum with internal vent                                                                                     • Protective tube for pressure
Protection class         IP68                                                                                                                                logger with B-coupler
Process connection       Standard thread ½-inch hydrant claw


                                                                                                                                                                                                             5
Phone +49 2452 962-400                             info@trotec.com
                                                                                                                       Fax +49 2452 962-200                               www.trotec.com




                        BENEFITS IN PRACTICE:

                        All-in-one system for mobile
                                                                     LD20PC correlator
                        loss analysis and reduction
                        in drinking water systems                    Multi-functional FFT high-performance correlator
                        48 bit three-point correlation               for leak detection in pressure pipelines
                        Onboard receiver for wireless data
                        logger read out from moving vehicles                                                                                                  Unique all-in-one system
                                                                                                                                                              for mobile loss analysis
                        Read out and analysis
                        of pressure data loggers
                                                                                                                                                              and reduction in drinking
                                                                                                                                                              water systems.
                        GPS-supported map software
                                                                                                                                                              W   FFT high performance
                        FFT and coherence function                                                                                                                correlation at up to three
                                                                                                                                                                  measuring points
                        Dissipation function
                        for selective squelching                                                                                                              W   onboard receiver for mobile
                                                                                                                                                                  read out of LD5L wireless
                        Automatic measuring function                                                                                                              data loggers
                        Highly-sensitive sound receiver and                                                                                                   W   mobile wireless data logger
                        high-performance radio transmitters                                                                                                       management – sound and
                        for distances up to 2,000 metres                                                                                                          pressure logger data analysis
                                                                                                                                                                  and management

                                                                                                                                                              W   all in only one device !

                                                                                                                                                                       High-performance
                                                                     Correlation measurements take
                                                                                                                                                                       software with clearly-
                                                                     on a whole new dimension with
                                                                     the mobile PC-based LD20PC
                                                                                                                                                                           structured user
                                                                     all-in-one system.                                                                                     interface
                                                                     Quality engineering “made in Germany”                                                                     Whether it’s the FFT or
                                                                     enables users to identify leaks extremely                                                                 the coherence function
                        Multi-functional all-in-one system           flexibly and effectively, thus avoiding                                                                 that you are using– the
                                                                     expensive excavations or digging at                                                                   GPS-supported CorControl
                        Three-point correlation                      wrong sites or locations.                                                                        software gives you a clear over-
                        An optional third receiver and a radio                                                                                                 view of all measuring data. Parameters
                                                                     The LD20PC is equipped with a steep                                                       like time signal, spectrum or coherence
                        transmitter with a separate radio fre-
                                                                     analogue filter and a dissipation function                                                can be changed independently
                        quency can be added to the two onboard
                                                                     which was developed in cooperation                                                        after measuring has been carried out.
                        receivers which are already standard for                                                  and data logger communication are in-
                        the TR-TA and TR-TB radio transmitters.      with the Fraunhofer Institute and there-                                                  The integrated data management pro-
                                                                                                                  tegrated in the centre of the system.
                        The three-point correlation enables you      fore able to determine and identify                                                       gram allows you to document all data
                                                                     background noises and interference           An optional Bluetooth transmitter allows     using the diagram or report function.
                        to achieve even faster measuring results
                        over greater measuring distances.            quickly and efficiently before subse-        you to conduct wireless measuring ope-
                                                                     quently effectively suppressing them.        rations with the PC correlator over
                        Mobile data logger management                                                             short distances separate from the sys-
                                                                     Special optionally available hydrophones
                                                                                                                  tem. Cordless wireless headphones
                        The LD20PC’s onboard receiver for            ensure accurate results in even the most
                        wireless data loggers makes the                                                           can be connected to provide you with
                                                                     difficult of situations, for example with
                        LD20PC excellently-suited for acoustic                                                    more mobility.
                                                                     plastic pipes and long pipe distances.
                        long-term zone monitoring.                                                                A combination comprising high perfor-
                                                                     Advancement through flexibilty               mance radio transmitters for distances
                        The logger data can be read out from
                                                                     The countless connection possibilities       up to 2,000 metres, an automatic mea-
                        a moving vehicle and analysed and
                        archived with the LogControl data log-       which the module has to offer provide        suring mode and a variety of individual
                        ger software used on the correlator.         the user with the greatest possible de-      setting options for frequency indepen-      nagement make the LD20PC the ideal
                                                                     gree of flexibility. As many as four re-     dent coherence and correlation analysis     correlator for water suppliers and mea-
                        In addition, the IR interface can be con -   ceiver units for three-point correlation     and additional wireless data logger ma-     surement service providers.
TRT-KAT-CORR-WM-04-EN




                        nected via the PC correlator’s USB inter-
                        face to read out the LD5DL pressure
                        data loggers                                 Three-point correlation                                                       Mobile data logger management
                                                                     Highly-sensitive body      Optional hydrophone    Permanent mag-              Onboard receiver for wire-   Connection for analysis
                        All measurement values can be dis-           sound receiver and         for direct use with    net for trouble-            less data logger read out    of LD5DL pressure data
                        played and documented centrally on the          high-performance        the medium water             free                  from moving measurement      loggers
                        LD20PC when used in combination with            radio transmitter                                    mounting              vehicles
                        the software for pressure data loggers.
                        The IR interface can also be connected via
                        the PC correlator’s USB interface to read
                        out the LD5DL pressure data loggers.




6
LEAK DETECTION




Why correlation? The benefits of this method…                                             Technical data                LD20PC
                                                                                          Article no.                   3.110.008.210




                                            Grafik © Trotec®
          Correlation is a computer-sup-




                                                                                                                                                                                          Trotec
          ported process which can be
                                                                                                                        Sturdy case with built-in PC correlator (notebook) and
          used to locate leaks extremely                                                                                integrated control panel with connections for headphone
accurately.                                                                                                             jack (automatic mute), transmitter input for optional wire-
All leaks emit sound. This sound travels                                                                                less headphones, cableless Bluetooth connection for
                                                                                          System module                 wireless measuring with the PC correlator over short
and is transferred to hydrants, armatures
                                                                                                                        distance separate from the system, onboard receiver
and valves. The sound is detected by




                                                                                                                                                                                          Telemetry
                                                                                                                        modules for wireless sensors and wireless data logger,
highly-sensitive signal receivers at up                                                                                 built-in loudspeakers, connection for antenna as well
to three contact measuring points and       wireless transmitter. The LD20PC calcu-                                     as power input cable ⁄ charging
transferred to the correlator via the LD    lates the exact position of the leak on
                                            the basis of the differences in the time                                    Three onboard receivers : 1 x for LD-TA transmitter, 1 x
                                                                                          Wireless receiver             for LD-TB transmitter, 1 x for LD5DL wireless data logger;
                                            that has elapsed between the signals




                                                                                                                                                                                          Planning and survey
                                                                                                                        optional an additional receiver for third transmitter LD-TC
                                            while taking various factors like material,
                                            pipe diameter and the length of the dis-                                    PC correlator (notebook) : external 12 V DC (car adapter)
                                            tance that was measured into account.                                       or Ansmann 230 V battery charger; system module :
                                                                                          Power supply
                                                                                                                        internal rechargeable battery (notebook), external 12 V DC
                                            When you are trying to detect a leak using                                  (car adapter) or 230 V AC
                                            other electroacoustic methods, there are
                                            a number of factors like the weather, the                                   48 bit three-point correlation
                                            depth in which the pipes have been laid                                     Frequency dependent coherence and correlation analysis




                                                                                                                                                                                          Temperature
                                            or high levels of background noise and
                                            other interference which can seriously                                      FFT analysis; accuracy > 5 cm, correlation resolution:
                                                                                                                        50,000 dots
                                            impair the success of your operation and
                                            make locating the leak extremely difficult.                                 Automatic or manual measurement with individual
                                            This is not the case when correlation is                                    parameter settings for measuring distance, filter and
                                            used to detect a leak.                                                      amplifier
                                                                                                                        Chebyshev analogue filter with 48 dB ⁄ octave rise
Standard scope of delivery:                 Optionally available accessories:             System and software




                                                                                                                                                                                          Velocity
• LD20PC – System module with PC            • LD-TC – Transmitter 3 incl. signal          functions                     Calibrating and documentation function
  correlator (notebook), control panel        receiver, colour blue                                                     Manual and automatic analogue ⁄ digital filtering
  and system connections, built into        • LD20PC 3F – Third radio frequency                                         to mask interference; high and low-pass filter
  a robust case                               for transmitter 3 (LD-TC)                                                 adjustable from 25 to 2,500 Hz
• CorControl analysis software              • LD20 MA – Magnet base antenna
• LogControl software for signal recep-       for correlator without amplifier                                           GIS compatible (acoustic zone monitoring with LogControl)
  tion of LD5L wireless data loggers




                                                                                                                                                                                          Moisture
                                            • LD20 MA+ – Magnet base                                                    GPS supported map software
• LD-TA –Transmitter 1 incl. signal           antenna for correlator with
                                                                                                                        Receiver function to read out wireless data loggers
  receiver, colour yellow                     amplifier (4 dB gain)
• LD-TB– Transmitter 2 incl. signal         • LD20 HYDRO – Hydrophone                                                   Connecting port for data logger analysis
  receiver, colour red                        without manometer
                                                                                          Dimensions                    Dimensions L 540 x W 440 x H 220 mm,
• LD K – soundproof                         • LD20 HYDRO UF – Adapter for                 (system module)               Weight 11 kg
  headphones                                                hydrophone on DIN




                                                                                                                                                                                          Multi-function
• Carry case for LD-                                            hydrant claw with
  TA, LD-TB and sys-                                             1-inch inner thread      Technical data                                     LD-TA                       LD-TB
  tem accessories                                                for assembly with
                                                                valve keys                Article no.                                   3.110.008.211                3.110.008.212
                                                                                                         Display                        graphic ⁄ numeric, automatic illumination         Tracing and detection

                                                                                                                                              Current ⁄ minimal sound level,
                                                                                                         Displayed values                  frequency high ⁄ low, amplification,
                                                                                                                                             battery status, battery capacity

                                                                                                         Radio frequency                             433 ⁄ 434 MHz
                                                                                                         Transmitter performance                   500 mW (licensed)
                                                                                          Transmitter
                                                                                                         Transmittal distance                        Up to 2,000 m
                                                                                                                                                                                      Optical inspection




                                                                                                         Operating ⁄ charging time                   approx. 9 h ⁄ 3 h
                                                                                                                                                                                           systems




                                                                                                         Protection class                                   IP65
                                                                                                         Dimensions                               225 x 165 x 100 mm
                                                                                                         Weight                                             2.9 kg
                                                                                                         Type                                            Piezoceramic
                                                                                                                                                                                          Leak detection




                                                                                          Signal         Sensitivity                                 > 1,000 pC ⁄ g
                                                                                          receiver       Mounting                                  Permanent magnet
                                                                                                         Operating temperature                     -20 °C to + 60 °C


                                                                                                                                                                                          7
Measuring technological innovations for
                    leak detection in drinking water systems

                    The LD-series in the MultiMeasure Professional programme provides
                    you with an optimally matched measuring equipment portfolio for leak
                    detection in drinking water systems.

                    All the measuring devices are high-quality, high-precision instruments
                    which carry all the hallmarks of superior tools made in Germany –
                    perfectly tuned to cope with the demands that daily use puts on them




                                        e


                            y                             i
                                                                                       u


                                                        r
                                                                          w
                        t
                                                                                        Grafik © Trotec®




                    w Long-term monitoring with wireless data loggers
                      designed to narrow down leaks.
                    e Quick logger data read out from a moving vehicle.
                    r FFT high-performance correlation.
                    t Acoustic pinpoint detection and route mapping with
                      a combi detector and ground sensor microphone.
                    y Acoustic body sound measurements
                    u Trace gas leak detection in drinking water systems.
                    i Leak detection and leak tightness inspection on
                      housing systems and industrial pipe networks.

                       And countless more application possibilities !

                    Do you still have any questions regarding the measuring technological
                    innovations in the LD-series? If so we would be most glad to help you.
                    Please feel free to give us a call or go straight to www.trotec.com
                    where you can find our complete selection of machines, measuring
                    devices, work tents and safety clothes and equipment.
TRT-ZBLD-WM-06-EN




                                            Trotec GmbH & Co. KG
                                            Grebbener Str. 7 · D-52525 Heinsberg
                                            Tel. +49 2452 962-400 · Fax +49 2452 962-200                  www.trotec-group.com
                                            info @ trotec.com · www.trotec.com

More Related Content

What's hot

Motorola symbol ls9208i barcode scanner - www.trridevlabelss.com
Motorola symbol ls9208i   barcode scanner - www.trridevlabelss.comMotorola symbol ls9208i   barcode scanner - www.trridevlabelss.com
Motorola symbol ls9208i barcode scanner - www.trridevlabelss.comTrridev Labelss Mfg Co
 
W-BAND RADIOMETER SYSTEM WITH SWITCHING FRONT-END FOR MULTI-LOAD CALIBRATION.pdf
W-BAND RADIOMETER SYSTEM WITH SWITCHING FRONT-END FOR MULTI-LOAD CALIBRATION.pdfW-BAND RADIOMETER SYSTEM WITH SWITCHING FRONT-END FOR MULTI-LOAD CALIBRATION.pdf
W-BAND RADIOMETER SYSTEM WITH SWITCHING FRONT-END FOR MULTI-LOAD CALIBRATION.pdfgrssieee
 
Vesda vlc500 vlc505 laser compact
Vesda vlc500 vlc505 laser compactVesda vlc500 vlc505 laser compact
Vesda vlc500 vlc505 laser compactsanzen enterprises
 
Testo 340 datasheet 2012
Testo 340 datasheet 2012Testo 340 datasheet 2012
Testo 340 datasheet 2012Testo Limited
 
02 a pcam dcv specification sheet
02 a pcam dcv specification sheet02 a pcam dcv specification sheet
02 a pcam dcv specification sheetIlias Varsamis
 
Cảm biến mức LR400
Cảm biến mức LR400Cảm biến mức LR400
Cảm biến mức LR400Bùi Thể
 
Up 15 K Brochure
Up 15 K BrochureUp 15 K Brochure
Up 15 K BrochureSean Miller
 
RFID embedded - MAGIC-PCB containing MAGICSTRAP
RFID embedded - MAGIC-PCB containing MAGICSTRAPRFID embedded - MAGIC-PCB containing MAGICSTRAP
RFID embedded - MAGIC-PCB containing MAGICSTRAPAlexander M. Schmoldt
 
Honeywell 5898-data-sheet
Honeywell 5898-data-sheetHoneywell 5898-data-sheet
Honeywell 5898-data-sheetAlarm Grid
 
Sirius T3 Brochure
Sirius T3 BrochureSirius T3 Brochure
Sirius T3 BrochureJon Mole
 
02 b pcam dcva specification sheet
02 b pcam dcva specification sheet02 b pcam dcva specification sheet
02 b pcam dcva specification sheetIlias Varsamis
 

What's hot (14)

Motorola symbol ls9208i barcode scanner - www.trridevlabelss.com
Motorola symbol ls9208i   barcode scanner - www.trridevlabelss.comMotorola symbol ls9208i   barcode scanner - www.trridevlabelss.com
Motorola symbol ls9208i barcode scanner - www.trridevlabelss.com
 
W-BAND RADIOMETER SYSTEM WITH SWITCHING FRONT-END FOR MULTI-LOAD CALIBRATION.pdf
W-BAND RADIOMETER SYSTEM WITH SWITCHING FRONT-END FOR MULTI-LOAD CALIBRATION.pdfW-BAND RADIOMETER SYSTEM WITH SWITCHING FRONT-END FOR MULTI-LOAD CALIBRATION.pdf
W-BAND RADIOMETER SYSTEM WITH SWITCHING FRONT-END FOR MULTI-LOAD CALIBRATION.pdf
 
Vesda vlc500 vlc505 laser compact
Vesda vlc500 vlc505 laser compactVesda vlc500 vlc505 laser compact
Vesda vlc500 vlc505 laser compact
 
Testo 340 datasheet 2012
Testo 340 datasheet 2012Testo 340 datasheet 2012
Testo 340 datasheet 2012
 
Industrial vli datasheet
Industrial vli datasheetIndustrial vli datasheet
Industrial vli datasheet
 
RFID - Reduce to the MAGICSTRAP 2.0
RFID - Reduce to the MAGICSTRAP 2.0RFID - Reduce to the MAGICSTRAP 2.0
RFID - Reduce to the MAGICSTRAP 2.0
 
02 a pcam dcv specification sheet
02 a pcam dcv specification sheet02 a pcam dcv specification sheet
02 a pcam dcv specification sheet
 
Irsens
Irsens Irsens
Irsens
 
Cảm biến mức LR400
Cảm biến mức LR400Cảm biến mức LR400
Cảm biến mức LR400
 
Up 15 K Brochure
Up 15 K BrochureUp 15 K Brochure
Up 15 K Brochure
 
RFID embedded - MAGIC-PCB containing MAGICSTRAP
RFID embedded - MAGIC-PCB containing MAGICSTRAPRFID embedded - MAGIC-PCB containing MAGICSTRAP
RFID embedded - MAGIC-PCB containing MAGICSTRAP
 
Honeywell 5898-data-sheet
Honeywell 5898-data-sheetHoneywell 5898-data-sheet
Honeywell 5898-data-sheet
 
Sirius T3 Brochure
Sirius T3 BrochureSirius T3 Brochure
Sirius T3 Brochure
 
02 b pcam dcva specification sheet
02 b pcam dcva specification sheet02 b pcam dcva specification sheet
02 b pcam dcva specification sheet
 

Similar to Trotec (20)

Rx 40 qz-2
Rx 40 qz-2Rx 40 qz-2
Rx 40 qz-2
 
Rx 40 qz-2
Rx 40 qz-2Rx 40 qz-2
Rx 40 qz-2
 
Rx 40 qz-2
Rx 40 qz-2Rx 40 qz-2
Rx 40 qz-2
 
Rx 40 qz-2
Rx 40 qz-2Rx 40 qz-2
Rx 40 qz-2
 
Rx 40 qz-2
Rx 40 qz-2Rx 40 qz-2
Rx 40 qz-2
 
Rx 40 qz-2
Rx 40 qz-2Rx 40 qz-2
Rx 40 qz-2
 
Rx 40 qz-2
Rx 40 qz-2Rx 40 qz-2
Rx 40 qz-2
 
RFID tags in tunnels
RFID tags in tunnelsRFID tags in tunnels
RFID tags in tunnels
 
Brochure Logis-Tech
Brochure Logis-TechBrochure Logis-Tech
Brochure Logis-Tech
 
Leakshooter brochure
Leakshooter brochureLeakshooter brochure
Leakshooter brochure
 
Cs3000
Cs3000Cs3000
Cs3000
 
Archer_VIVID_Qteq
Archer_VIVID_QteqArcher_VIVID_Qteq
Archer_VIVID_Qteq
 
App152 en measurement-railroad-rails-laser-profile-sensors
App152 en measurement-railroad-rails-laser-profile-sensorsApp152 en measurement-railroad-rails-laser-profile-sensors
App152 en measurement-railroad-rails-laser-profile-sensors
 
DTX CableAnalyzer
DTX CableAnalyzerDTX CableAnalyzer
DTX CableAnalyzer
 
The evolution of scopes
The evolution of scopesThe evolution of scopes
The evolution of scopes
 
Katalog fluke-oscilloscopes- for-field-applications-by-tridinamika
Katalog fluke-oscilloscopes- for-field-applications-by-tridinamikaKatalog fluke-oscilloscopes- for-field-applications-by-tridinamika
Katalog fluke-oscilloscopes- for-field-applications-by-tridinamika
 
High pressure full-bore flow meter
High pressure full-bore flow meterHigh pressure full-bore flow meter
High pressure full-bore flow meter
 
Portable Ultrasonic Flaw Detector by ACMAS Technologies Pvt Ltd.
Portable Ultrasonic Flaw Detector by ACMAS Technologies Pvt Ltd.Portable Ultrasonic Flaw Detector by ACMAS Technologies Pvt Ltd.
Portable Ultrasonic Flaw Detector by ACMAS Technologies Pvt Ltd.
 
Early kick detection (ekd) system
Early kick detection (ekd) system Early kick detection (ekd) system
Early kick detection (ekd) system
 
Vli880
Vli880Vli880
Vli880
 

Trotec

  • 1. Measuring technological innovations for leak detection in drinking water systems Combi leak detector FFT high performance Wireless sound correlator logging system EXCLUSIVE at Trotec ! Pressure data Trace gas Pulse wave logger sensors generator Professional solutions for zone measurements, prelocation and pinpoint detection Water loss reduction Measuring data documentation
  • 2. Phone +49 2452 962-400 info@trotec.com Fax +49 2452 962-200 www.trotec.com BENEFITS IN PRACTICE: Acoustic and trace gas leak detection LD6000 combi-detector in only one device High-resolution colour graphic display Leak detection and acoustic pipe location with touchscreen functions The only one of its kind in its EXCLUSIVE class. State-of-the-art smart at Trotec ! function for even faster pinpoint leak detection (patent filed) Numerous preprogrammed common applications for quick access All filters and parameters can be configured individually Pipe detection mode Complies with all guidelines govern- ing according to VBG 121 (when used with original headphones) (VBG - trade association safety regulations) Highly-sensitive, high-quality, robust precision microphone made in Germany The LD6000 cutting-edge Whether you need it for laying out pipes Long-term measurements leak detection device sets or to narrow down the search or pinpoint In order to be new standards in the field a leak – the highly-sophisticated LD6000 able to pinpoint and the high-quality microphone, which the leak exact - of leak detection… both carry the hallmarks of a product ly, an onboard W Acoustic pinpoint made in Germany, allow you to determine sound logger can be activated to log leak detection even the tiniest of leaks and display the measurements carried out over a period W Pipe detection signal before it is processed. of up to 60 minutes, which can then W Long-term measuring be used to determine or rule out any with logging function Overview of the functions leaks with the help of the recorded measurement curve. W Trace gas detection F&L mode – hear and see leaks W All in only one device ! Pipe detection mode As many as ten measuring cycles are dis- played either as a number or a two-seg- This mode is designed especially to de- ment colour bar – one for frequency and tectplastic pipes which are subjected one for volume. The leak is there where to ultrasound via the LD-PULS impulse the two segments are at their steepest. generator. y Smart mode Trace gas detection r The state-of-the-art smart function Trace gas can be used in combination is the only one of its kind in its with the LD6000 H2 hydrogen sensor t class and has been filed for patent to carry out quick and effective leak – the smarter way to find leaks. w detection in pipe networks and pipe Complex algorithmic calculations which systems in houses. are carried out unseen in the heart of the device provide you with a clear The trace gas used is hydrogen, which e view of what you need to see: the exact due to its specific structure is able to Grafik © Trotec® position of the leak, revealed to you by penetrate and pass through various ma- means of a bar indicator which rises terials like soil, concrete, tiles etc. easily sharply where the leak is. It doesn’t get before then being detected by the sensor at the places where it escapes through TRT-KAT-LEDE-WM-06-EN any easier than that! The innovative, state-of-the-art LD6000 combi detector is suitable for a variety the system that is being inspected. of different application and allows you to detect leaks using both the acoustic The LD6000 is able to show the exact and trace gas method with only a single device. concentration of hydrogen. The thresh- G Acoustic pinpoint leak detection with geophone h Detection and pipe laying, olds can be individually configured and also for plastic pipes j acoustic body sound measurement. k trace gas leak an acoustic and optical signal warns detection in drinking water systems. l leak detection and leak tightness inspection of pipe systems in houses and industrial pipe networks. the user when these thresholds have been exceeded. 2
  • 3. LEAK DETECTION The principle of acoustic Standard scope of delivery: i e leak detection • LD6000 measuring device . • LD K – sound blocking headphones e Trotec Water which escapes from high-pres- • LD6000 BM – universal microphone sure pipes at high speed causes fric- with magnet adapter r tion which in turn can be picked up • LD6000 DA – tripod adapter t in the form of sound waves. r • LD6000 VL – stick extension with tip y The pipes themselves start to oscil- • LD6000 TG – shoulder strap u late. The sound that is generated is Telemetry y • PC connecting cable transmitted through the pipes and w o • LD6000 carry case can be transformed into audible sound with a body sound micro- Optionally available accessories: phone at a distant contact point • LD6000 BMW – (valve, hydrant, armature). wind protected ground microphone Planning and survey t (with dead-man’s button) Y In addition the water leaking out u through the crack or hole in the pipe • LD6000 VK – connecting cable generates sound which is carried • LD6000 DM – tripod magnet for through the ground to the surface. LD6000 BMW ground microphone o p a • LD6000 H2 – This sound can be picked up by a geophone and transformed into au- hydrogen hand sensor p dible sound. • LD6000 H2 – hydrogen ground sensor O Temperature Technical data LD6000 LD-PULS pulse wave generator Article no. 3.110.008.010 This impulse generator is excellently- Acoustic leak detection (F & V, Smart, long-term measuring), Operating mode suited for use with the LD6000 meas- pipe detection and trace gas leak detection uring device. Measuring modes for minimum level, averaged level, pulse wave measurements, simultaneous F&V analysis, The LD-PULS is not affected by electric Velocity logging function, automatic functions for setting filter cables and can detect non-metallic wa- Measuring and frequencies and sensor sensitivity, memory preference ter pipes up to a depth of 2 metres device functions for manual filter settings, sound level overmodulation protection, trace gas detection with concentration- without having to close off any part of dependent signal (optic and acoustic) the network or system. Controls Either via touchscreen, keys or control dial The LD-PULS generates up to 60 oscil- Amplification 120 dB low noise factor lations per minute which under Moisture Input impedance 1M Ω favourable conditions can spread out Up to 256 can be configured individually as far as 600 m into the pipe before be- Filter ing detected by a ground microphone. (for stick sensor and ground microphone) Display Colour LCD (automatic illumination), 480 x 272 pixels This means that this method can be Battery check Via micro-controller used to compile, complete or check plans and pipe layouts or networks. Multi-function Output impedance ≤ 10 Ω Power supply 4 x batteries type LR14 C 1.5 V Operating time up to 14 h in non-stop operation, up to 40 h in normal operation Bayonet nut connector (microphone / sensor), Standard scope of delivery: Connections 6.3 mm jack plug (headphones) • LD-PULS – pulse wave generator Protection class IP54 Tracing and detection built into sturdy case with integrated Housing Aluminium, powder-coated rechargeable battery Temperature conditions During operation: -5 °C to +55 °C; Storage: -25 °C to +65 °C • Separate power supply for LD-PULS Dimensions approx. L 210 x W 160 x H 60 mm Optionally available accessories: Weight approx. 1,050 g • LD-PULS repair set containing an Allen key and 4 valves Technical data LD6000 H2 hydrogen hand and ground sensor Optical inspection Article no. 3.110.008.111 3.110.008.015 systems Response sensitivity 1 ppm H₂ Technical data LD-PULS Measuring range 10 ppm H₂ to 20,000 ppm H₂ Article no. 3.110.008.012 Resolution 1 ppm H₂ Minimum pressure 2 bar (29 psi) (minimum pressure of the service pipes) Reaction time 0.5 s Operating time Approx. 12 hours Hand sensor with flexible swan-neck (length 50 cm) Pulse sequence Approx. 60 per minute Leak detection and 160 cm connecting cable for LD6000 Design Connection 1-inch GEKA high pressure coupling Ground sensor with two-part stick microphone (length approx.1 m) and rubber sleeve, approx. 200 cm Internal battery (rechargeable) Power supply connecting cable for LD6000 or 230V AC Temperature conditions During operation: -10 °C to +60 °C; Storage -20 °C to +60 °C Weight 4.2 kg 3
  • 4. Phone +49 2452 962-400 info@trotec.com Fax +49 2452 962-200 www.trotec.com BENEFITS IN PRACTICE: LD5L and LD5LR wireless data loggers: Sound and pressure data logger Localisation of leaks Mobile zone monitoring of drinking water systems using long-term monitoring Wireless measuring data transfer Leaks in drinking water systems do not only endanger Quick logger data read out the quality of your water supply – precious water seeps from moving vehicles out uncontrollably resulting in losses worth hundreds Extremely economical or thousands of pounds... Sound level detection, The mobile wireless monitoring analysis and logging system in the Trotec MultiMeasure Easy to use Professional Series enables you to carry out reliable acoustic zone Including LogControl user measurements in drinking water software, GIS compatible systems in order to detect possible cracks, fissures and leaks. A magnetic base and optionally available mounts and brackets allow you to posi- tion your wireless data logger in a va- riety of different positions to measure the sound levels in the pipe system or network. BENEFITS IN PRACTICE: In addition, a model with a hydrophone LD5DL pressure data logger : can be used for measuring operations that are carried out with the medium Designed specifically for monitoring water – ideal for plastic pipes or pipe pressure in water supplies. networks that cover greater distances. Robust, waterproof– no prod contacts The wireless data loggers detect, analyse and log sound levels during the night Foil keys for on-site programming when less water flows through the sys- All logging data from the LD5LR receiver Extremely large memory for more tems and transmits all the measuring can be transferred to a PC via the USB than 240,000 measuring values data up to 12 times a minute. interface for further analysis and docu- mentation. Very high measuring sensitivity All measuring data can be picked up and logged from a passing vehicle with The LogControl data bank Infrared / USB data transfer the use of a mobile LD5LR receiver. supported software included and infrared / GSM (optional) The leak status and further measuring in the scope of delivery is Battery life for approx. data are displayed directly on the GIS compatible and pro- signed and individual regions can be 10,000,000 measuring values LD5LR’s easy-to-read display. vides graphic supported created to establish a borderline be- functions for analysis and tween different pressure zones. e management. Individual pipe plans can LD5LR standard scope of delivery: be transformed into maps, • LD5LR receiver (read out device) w for example; individual log- • six LD5L data loggers with magnet y ger locations and meas- base and onboard antenna e urement series can be as- • Switching magnet r r • USB cable • LD5L carry case • LogControl software Optionally available accessories: • LD5L WA – angle adapter for wireless data logger t t • LD5L HYDRO – acoustic wireless data logger with hydrophone TRT-KAT-FDAL-WM-05-EN sensor (hydrophone logger) y • LD5L HYDRO UF – adapter for w hydrophone logger for assembly in DIN hydrant claw, ½-inch inner thread with vent, for assembly with key valve 4
  • 5. LEAK DETECTION The measuring values logged by the wire- Technical data LD5LR receiver less data logger are transmitted Article no. 3.110.008.110 automatically to the passing Trotec vehicle and recorded by Statistic minimum level of the previous night, the L5LR receiver. level progress of the past 14 days, quietest and Description loudest level during the last 10 minutes, selection time, leak status, amplifier, logger serial number Memory Automatic (the last 14 measuring cycles) Memory capacity Up to 100 loggers (optionally 2,000 loggers) Telemetry Display LCD backlight, 128 x 64 pixels Transmitter frequency 433 MHz (other frequencies on request) The measuring Power supply 4 x type LR03 AAA 1.5 V batteries Grafik © Trotec® engineer can calibrate a leak Interface USB directly on site with a correlator or a sound Planning and survey Temperature range -15 °C to +55 °C locator by using the direct optical leak status indicator on the display of the receiver if required. Dimensions 200 x 95 x 30 mm, Weight 350 g Technical data Article no. LD5L wireless data logger 3.110.008.120 LD5DL pressure data logger The LD5DL pressure data logger has permanent (07:00am to 07:00pm 12x per minute; Data transfer been designed especially for monitoring 07:00pm to 07:00am : 1x per minute.) pressure in water supplies. Its internal Statistic minimum level of the previous night, level progress Temperature of the past 14 days, quietest level (AL) and loudest level (AH) vent makes it ideally suited for precise Data logging pressure progress measurements for during the last 10 minutes, amplifier, quality of the measure- ment (rain, wind etc.), logger serial number logger location pipe networks and tempering water and Amplification 200,000 times for pressure sampling. Recording period 2:00 o’clock to 4 o‘clock The high sampling rate of up to 10 Transmitting power 10 mW measurements per second enables the Transmitter frequency 433 MHz (other frequencies on request) logger to detect even short pressure Velocity surges reliably before logging them. Memory capacity 14-day ring memory Protection class IP68 The LD5DL can store up to 240,000 Nitrogen-filled housing 1.5 bar, measuring values and present them Type of housing on its easy-to-read display. The logger condensate protected circuit board Sensor piezo ceramic is operated via the USB interface of your PC or a GSM module at the logger Moisture Temperature range -15 °C to +55 °C itself. Measurements with the LD5DL Operating time 5 years (without having to change the battery) can be easily carried out from as little Dimensions ø 40 ⁄ 44 mm ⁄ Height 110 mm; onboard antenna as one second to several months. Dimensions (english construction); Weight approx. 450 g LD5DL basic package 1 * The data stored in the pressure data Technical data LD5DL pressure data logger • LD5DL – pressure logger with ½- logger can be read out via the IR-USB Multi-function Article no. 3.110.008.130 inch outer thread, 0 to 20 bar interface and transferred to your PC • LogControl DL software and analysed using the LogControl DL Water pressure sensor, (optional temperature ⁄ air pressure Sensors (internal) LD5DL basic package 2 * software included in the scope of delivery. sensor for altitude determination) Pressure measuring Standard sensor 20 bar; further pressure ranges 1 ⁄ 1.6 ⁄ 2.5 ⁄ • LD5DL UF pressure logger with ½- The data bank ranges 4 ⁄ 6 ⁄ 10 ⁄ 16 ⁄ 25 bar, possible up to max. 50 bar inch outer thread and below ground hydrant claw, mounted (in compli- supported soft- Measuring cell Long-term stable, piezo resistive, temperature compensated ware enables Tracing and detection ance with DIN), 0 to 20 bar Temperature range Up to 70 °C • Software LogControl DL you to process Measuring accuracy < 1 % from final value at 20 °C • Assembly aid with hydrant base DIN single meas- ± 0.005 % (over the whole measuring range), LD5DL basic package 3 * ** urements graphically or transfer various Resolution measuring curves. There is also an export for example 0.5 mbar at 10 bar measuring range • LD5DL OF pressure logger with ½- 1 s to 24 h (can be configured individually), inch outer thread and above ground function available which allows you to Measuring interval 0.1 s to 1 s (shock pressure recognition) hydrant claw (3-inch thread), mounted archive your data flexibly. exact quartz measurement with time and date, starting time (in compliance with DIN), 0 to 20 bar Optical inspection Real-time clock Optionally available accessories of the measuring data logging can be selected individually • LogControl DL software systems for LD5DL pressure loggers: Memory capacity > 240,000 measuring values Minimum required features: buffered RAM (measuring value conservation * 1 x LD5DL IR-USB interface (read out device) • LD5DL IR-USB interface – read out Memory type ** adapter für B-connection incl. B-coupler device with for the LD5DL with USB during battery change) interface Interface Infrared ⁄ USB data transfer (infrared ⁄ GSM optional) • LD5DL 20 up to max. 300 bar Display LCD • External GSM module for LD5DL Leak detection Lithium battery 3.6 V ⁄ 8.5 AH type AA, battery life • Adapter for B-connection incl. Power supply approx. 10,000,000 measuring values B-coupler Type of housing Stainless steel ⁄ aluminum with internal vent • Protective tube for pressure Protection class IP68 logger with B-coupler Process connection Standard thread ½-inch hydrant claw 5
  • 6. Phone +49 2452 962-400 info@trotec.com Fax +49 2452 962-200 www.trotec.com BENEFITS IN PRACTICE: All-in-one system for mobile LD20PC correlator loss analysis and reduction in drinking water systems Multi-functional FFT high-performance correlator 48 bit three-point correlation for leak detection in pressure pipelines Onboard receiver for wireless data logger read out from moving vehicles Unique all-in-one system for mobile loss analysis Read out and analysis of pressure data loggers and reduction in drinking water systems. GPS-supported map software W FFT high performance FFT and coherence function correlation at up to three measuring points Dissipation function for selective squelching W onboard receiver for mobile read out of LD5L wireless Automatic measuring function data loggers Highly-sensitive sound receiver and W mobile wireless data logger high-performance radio transmitters management – sound and for distances up to 2,000 metres pressure logger data analysis and management W all in only one device ! High-performance Correlation measurements take software with clearly- on a whole new dimension with the mobile PC-based LD20PC structured user all-in-one system. interface Quality engineering “made in Germany” Whether it’s the FFT or enables users to identify leaks extremely the coherence function Multi-functional all-in-one system flexibly and effectively, thus avoiding that you are using– the expensive excavations or digging at GPS-supported CorControl Three-point correlation wrong sites or locations. software gives you a clear over- An optional third receiver and a radio view of all measuring data. Parameters The LD20PC is equipped with a steep like time signal, spectrum or coherence transmitter with a separate radio fre- analogue filter and a dissipation function can be changed independently quency can be added to the two onboard which was developed in cooperation after measuring has been carried out. receivers which are already standard for and data logger communication are in- the TR-TA and TR-TB radio transmitters. with the Fraunhofer Institute and there- The integrated data management pro- tegrated in the centre of the system. The three-point correlation enables you fore able to determine and identify gram allows you to document all data background noises and interference An optional Bluetooth transmitter allows using the diagram or report function. to achieve even faster measuring results over greater measuring distances. quickly and efficiently before subse- you to conduct wireless measuring ope- quently effectively suppressing them. rations with the PC correlator over Mobile data logger management short distances separate from the sys- Special optionally available hydrophones tem. Cordless wireless headphones The LD20PC’s onboard receiver for ensure accurate results in even the most wireless data loggers makes the can be connected to provide you with difficult of situations, for example with LD20PC excellently-suited for acoustic more mobility. plastic pipes and long pipe distances. long-term zone monitoring. A combination comprising high perfor- Advancement through flexibilty mance radio transmitters for distances The logger data can be read out from The countless connection possibilities up to 2,000 metres, an automatic mea- a moving vehicle and analysed and archived with the LogControl data log- which the module has to offer provide suring mode and a variety of individual ger software used on the correlator. the user with the greatest possible de- setting options for frequency indepen- nagement make the LD20PC the ideal gree of flexibility. As many as four re- dent coherence and correlation analysis correlator for water suppliers and mea- In addition, the IR interface can be con - ceiver units for three-point correlation and additional wireless data logger ma- surement service providers. TRT-KAT-CORR-WM-04-EN nected via the PC correlator’s USB inter- face to read out the LD5DL pressure data loggers Three-point correlation Mobile data logger management Highly-sensitive body Optional hydrophone Permanent mag- Onboard receiver for wire- Connection for analysis All measurement values can be dis- sound receiver and for direct use with net for trouble- less data logger read out of LD5DL pressure data played and documented centrally on the high-performance the medium water free from moving measurement loggers LD20PC when used in combination with radio transmitter mounting vehicles the software for pressure data loggers. The IR interface can also be connected via the PC correlator’s USB interface to read out the LD5DL pressure data loggers. 6
  • 7. LEAK DETECTION Why correlation? The benefits of this method… Technical data LD20PC Article no. 3.110.008.210 Grafik © Trotec® Correlation is a computer-sup- Trotec ported process which can be Sturdy case with built-in PC correlator (notebook) and used to locate leaks extremely integrated control panel with connections for headphone accurately. jack (automatic mute), transmitter input for optional wire- All leaks emit sound. This sound travels less headphones, cableless Bluetooth connection for System module wireless measuring with the PC correlator over short and is transferred to hydrants, armatures distance separate from the system, onboard receiver and valves. The sound is detected by Telemetry modules for wireless sensors and wireless data logger, highly-sensitive signal receivers at up built-in loudspeakers, connection for antenna as well to three contact measuring points and wireless transmitter. The LD20PC calcu- as power input cable ⁄ charging transferred to the correlator via the LD lates the exact position of the leak on the basis of the differences in the time Three onboard receivers : 1 x for LD-TA transmitter, 1 x Wireless receiver for LD-TB transmitter, 1 x for LD5DL wireless data logger; that has elapsed between the signals Planning and survey optional an additional receiver for third transmitter LD-TC while taking various factors like material, pipe diameter and the length of the dis- PC correlator (notebook) : external 12 V DC (car adapter) tance that was measured into account. or Ansmann 230 V battery charger; system module : Power supply internal rechargeable battery (notebook), external 12 V DC When you are trying to detect a leak using (car adapter) or 230 V AC other electroacoustic methods, there are a number of factors like the weather, the 48 bit three-point correlation depth in which the pipes have been laid Frequency dependent coherence and correlation analysis Temperature or high levels of background noise and other interference which can seriously FFT analysis; accuracy > 5 cm, correlation resolution: 50,000 dots impair the success of your operation and make locating the leak extremely difficult. Automatic or manual measurement with individual This is not the case when correlation is parameter settings for measuring distance, filter and used to detect a leak. amplifier Chebyshev analogue filter with 48 dB ⁄ octave rise Standard scope of delivery: Optionally available accessories: System and software Velocity • LD20PC – System module with PC • LD-TC – Transmitter 3 incl. signal functions Calibrating and documentation function correlator (notebook), control panel receiver, colour blue Manual and automatic analogue ⁄ digital filtering and system connections, built into • LD20PC 3F – Third radio frequency to mask interference; high and low-pass filter a robust case for transmitter 3 (LD-TC) adjustable from 25 to 2,500 Hz • CorControl analysis software • LD20 MA – Magnet base antenna • LogControl software for signal recep- for correlator without amplifier GIS compatible (acoustic zone monitoring with LogControl) tion of LD5L wireless data loggers Moisture • LD20 MA+ – Magnet base GPS supported map software • LD-TA –Transmitter 1 incl. signal antenna for correlator with Receiver function to read out wireless data loggers receiver, colour yellow amplifier (4 dB gain) • LD-TB– Transmitter 2 incl. signal • LD20 HYDRO – Hydrophone Connecting port for data logger analysis receiver, colour red without manometer Dimensions Dimensions L 540 x W 440 x H 220 mm, • LD K – soundproof • LD20 HYDRO UF – Adapter for (system module) Weight 11 kg headphones hydrophone on DIN Multi-function • Carry case for LD- hydrant claw with TA, LD-TB and sys- 1-inch inner thread Technical data LD-TA LD-TB tem accessories for assembly with valve keys Article no. 3.110.008.211 3.110.008.212 Display graphic ⁄ numeric, automatic illumination Tracing and detection Current ⁄ minimal sound level, Displayed values frequency high ⁄ low, amplification, battery status, battery capacity Radio frequency 433 ⁄ 434 MHz Transmitter performance 500 mW (licensed) Transmitter Transmittal distance Up to 2,000 m Optical inspection Operating ⁄ charging time approx. 9 h ⁄ 3 h systems Protection class IP65 Dimensions 225 x 165 x 100 mm Weight 2.9 kg Type Piezoceramic Leak detection Signal Sensitivity > 1,000 pC ⁄ g receiver Mounting Permanent magnet Operating temperature -20 °C to + 60 °C 7
  • 8. Measuring technological innovations for leak detection in drinking water systems The LD-series in the MultiMeasure Professional programme provides you with an optimally matched measuring equipment portfolio for leak detection in drinking water systems. All the measuring devices are high-quality, high-precision instruments which carry all the hallmarks of superior tools made in Germany – perfectly tuned to cope with the demands that daily use puts on them e y i u r w t Grafik © Trotec® w Long-term monitoring with wireless data loggers designed to narrow down leaks. e Quick logger data read out from a moving vehicle. r FFT high-performance correlation. t Acoustic pinpoint detection and route mapping with a combi detector and ground sensor microphone. y Acoustic body sound measurements u Trace gas leak detection in drinking water systems. i Leak detection and leak tightness inspection on housing systems and industrial pipe networks. And countless more application possibilities ! Do you still have any questions regarding the measuring technological innovations in the LD-series? If so we would be most glad to help you. Please feel free to give us a call or go straight to www.trotec.com where you can find our complete selection of machines, measuring devices, work tents and safety clothes and equipment. TRT-ZBLD-WM-06-EN Trotec GmbH & Co. KG Grebbener Str. 7 · D-52525 Heinsberg Tel. +49 2452 962-400 · Fax +49 2452 962-200 www.trotec-group.com info @ trotec.com · www.trotec.com