Thorne & Derrick UK are specialist distributors of Hadar Hazardous Area Lighting ranges providing expert technical guidance, site surveys, competitive quotations, ex stock delivery and a comprehensive lighting design service - this includes Zone 1 and Zone 2 (ATEX) fluorescent, recessed, portable, bulkhead, wellglass and floodlights.
Hadar Hazardous Area Lighting is a specialist manufacturer of hazardous area lighting for the oil, gas, petro-chemical, pharmaceutical, offshore and marine industries worldwide offering the design and production of lighting products for Zone 1, 2, 21 & 22, Gas and Dust - this includes ATEX and IEC Ex Explosion Proof Exe & Ex d Lighting ranges : flourescent, recessed, helideck, LED floodlight, bulkhead and well glass.
Hazardous Area Flood Lights - ATEX Certified
Zone 2 Floodlights
150W SON, 250W SON, 400W SON, 500W Tungsten Halide
Petrel hazardous area (ATEX certified) Zone 2 floodlights are extensively specified for Ex e lighting applications.
Petrel Hazardous Area Zone 2 Flood Lighting (ATEX) - Ex
Zone 2 Flood Light
Petrel hazardous area Zone 2 floodlights are made from die cast aluminium and incorporate assymetrical reflector as standard - Zone 2 floodlights can be fitted with a range of control gear suitable for lamps from 150w to 500w. Petrel ZT hazardous area Zone 2 floodlight is ATEX certified for use with SON, MBF and tungsten lamps.
Zone 2 Floodlights, Hazardous Area Lighting (ATEX) - Petrel ZT Flood Light
Benefits
Symmetrical reflector allows maximum directional light output
Graduated mounting bracket allows for consistent installation angle for multiple units
Easy re-lamping via hinged front section
Options
Sodium, metal halide, and tungsten lamp options
Other colours available
Petrel ZT150 (150W SON), ZT250 (250W SON), ZT400 (400W SON)
Petrel ZT500 (500W tungsten halide)
Features
230v 50Hz standard
-20°C to +30°C standard supply subject to ambient temperature requirements.
Tubular : SON, MBI, Tungsten. 70w to 500w Symmetrical reflector fitted to all versions (lamps not provided).
Hazardous Area Zones Classification
Zone 2 - where flammable atmosphere is not likely to occur during normal operation and if it does will only exist for short period of time, typically less than 10 hours per year.
Thorne & Derrick UK are official stockists and distributors for the Petrel Explosion Proof and Hazardous Area Lighting ranges for Zone 1 and Zone 2 lighting installations with ATEX certification – this includes hazardous area fluorescent, bulkhead, floodlight and wellglass lighting. EX Lighting Products from Petrel Hazardous Area Electrical Equipment : Ex de Well Glass, Ex d Emergency Flourescent Luminaire, Ex de Bulkhead, Ex de Zone 1 Floodlight, Zone 2 Floodlight, Ex ed Standard & Emergency Flourescent Luminaire, Zone 2 Standard & Emergency Flourescent Luminaire, Ex d Flourescent Luminaire, Zone 2 Bulkhead Luminaire, Ex ed Recessed Zone 1 Flourescent Luminaire.
Zone 2 Floodlights
ATEX Certified Hazardous Area Floodlights
Petrel hazardous area (ATEX certified) Zone 2 floodlights are extensively specified for Ex e lighting applications.
Petrel ZT150 - 150W - SON Floodlight for Zone 2 Hazardous Areas - ATEX Group II Cat 3GD
Petrel ZT Zone 2 Floodlights provide following benefits :
* Hinged lid opening for safe re-lamping in hazardous areas
* Graduated angle bracket for fast, accurate installations
* Lightweight but strong die cast aluminium floodlight
* Asymmetric reflector for maximum downward light output
Petrel Hazardous Area Zone 2 Flood Lighting (ATEX) - Ex
Zone 2 Flood Light
Petrel hazardous area Zone 2 floodlights are made from die cast aluminium and incorporate assymetrical reflector as standard - Zone 2 floodlights can be fitted with a range of control gear suitable for lamps from 150w to 500w. Petrel ZT hazardous area Zone 2 floodlight is ATEX certified for use with SON, MBF and tungsten lamps.
Hazardous Area Zones Classification
Zone 2 - where flammable atmosphere is not likely to occur during normal operation and if it does will only exist for short period of time, typically less than 10 hours per year.
ATEX Certified Lighting for Hazardous Areas Zones 1 & Zones 2
ATEX is the name given to a set of European Directives relating to Hazardous Area Electrical & Lighting Equipment Installations (Flammable Atmospheres) to avoid industrial accident or incident, this cover hazardous area lighting Zone 1 and Zone 2 installations. ATEX Directive 94/9/EC (ATEX 95), is a directive adopted by the EU under the “New Approach” strategy. The “New Approach” ATEX directive supersedes the “Old Approach” ATEX Directive, the Potentially Explosive Atmospheres Directive, 76/117/EEC – ATEX 94/9/EC (ATEX 95) facilitates free trade in the EC for hazardous area lighting and electrical equipment intended to be used in potentially explosive atmospheres. ATEX Directive 94/9/EC (ATEX 95) covers “Electrical Equipment” used in hazardous areas with potentially explosive atmospheres created by presence of gases, vapours, mists or dusts.
Thorne & Derrick UK are specialist distributors of Petrel Hazardous Area Lighting ranges providing expert technical guidance, site surveys, competitive quotations, ex stock delivery and a comprehensive lighting design service - this includes hazardous area Zone 1 and Zone 2 (ATEX) fluorescent, recessed, portable, bulkhead, wellglass and floodlights.
Petrel Hazardous Area Lighting is a specialist manufacturer of hazardous area lighting for the oil, gas, petro-chemical, pharmaceutical, offshore and marine industries worldwide offering the design and production of lighting products for Zone 1, 2, 21 & 22, Gas and Dust - this includes ATEX and IEC Ex Explosion Proof Exe & Ex d Lighting ranges : fluorescent, recessed, helideck, LED floodlight, bulkhead and well glass.
Marechal SPeX Single Pole Power Connector
Zone 1 & Zone 2 Zone 21, Zone 22
680 Amp IP65/IP66 Water & Dust-tight
Marechal Hazardous Area Plugs & Sockets
1000V a.c. / 1500V d.c. single pole, 6800A ‘e' increased safety Marechal SPeX plug and socket power connector enables the user to connect and disconnect heavy duty equipment simply and safely in hazardous area zones 1, 2, 21 and 22.
Designed for use in hazardous areas the Marechal SPeX plug and socket assembly is ATEX 94/9/CE approved for zones 1 & 2 (gas) and zones 21 & 22 (dust). Marechal SPeX offers automatic IP66/IP67 ingress protection rating as soon as the plug is inserted into the socket. Electromechanical interlocking is provided via a microswitch (which opens and closes all phases simultaneously) to protect the user and to prevent electrical destabilisation of equipment.
The Marechal casing is manufactured in glassfibre-reinforced polyester which affords excellent mechanical protection (IK08) and resistance to UV and chemical agents. Typical applications include mobile gensets, ship-to-shore supplies, mines, offshore platforms etc.
The incorrect mating of phases is mechanically impossible. Furthermore colour-coding enables a visual check.
Marechal SPeX Single Pole Power Connector
Marechal SPeX - EX ATEX Hazardous Area Plug, Socket Power Connector
Enhanced protection mode « e »
Compliant with ATEX 94/9/CE Directive
Zones 1 and 2 (gas) and zones 21 and 22 (dust)
Up to 680 A
Up to 1000 V a.c.
Interlock switch system via pilot contacts, synchronized connection and disconnection for all phasesMechanical keying system with 5 positions to discriminate between phases
Visual identification of phases with standard colour codes
Automatically IP65 dust and watertight
IK08 shock resistant GRP casings
Resistant to temperature changes: -40 °C to +60 °C
Marechal DS range of industrial power supply and motor connection plugs and sockets provide low voltage distribution, 30amps-250amps. Marechal DS range industrial plugs are the quality standard for manufacturing industry providing the following benefits compliant with International Standard IEC60309-1 and European Standard EN60309-1 (Plugs & Sockets Outlets for Industrial Purposes).
Marechal DS Power Supply and Motor Connection Plugs and Sockets
30amp-250amp current ratings for plugs and sockets
500v-1000v a.c. rated plugs and sockets
IP54/IP55 water and dust tight plug assemblies (IP66/IP67 available)
AC-22 / AC-23 load breaking capability
GRP casings, chemical and IK08 shock resistant
Metal casings, corrosion resistant, IK09 shock resistant
Resistant to temperature changes -40 to +60 Degrees Celsius
Equipped with silver-nickel butt contacts for lifetime reliability
Typical Marechal DS Industrial Plugs Applications - power supply to motor and pump connections, heavy industry, mines and quarries, ship to shore plug connections, gensets, power supply to production lines and manufacturing operations. Marechal DS plugs and sockets range of decontactors is supported by a full line of wall mounting sockets, inclined sockets, coupler sockets, wall mounting appliance inlets and inclined appliance inlets.
Marechal DS Plugs & Sockets Decontactors - The Range
Marechal DS1 Plugs - 30amp
Marechal DS3 Plugs - 50am
Marechal DS6 Plugs - 90amp
Marechal DS9 Plugs - 150amp
Marechal DS2 Plugs - 250amp
Marechal Electric pioneered the use of high performance, silver-nickel butt contacts in electrical plug and socket systems (decontactors), which are now available for applications from simple compact multi-pin to heavy duty 600A plug connections. Marechal technology is used across a range of demanding environments such as the food and drink, nuclear power, heavy industry, infrastructure and ATEX hazardous area sectors. Marechal decontactors are an effective alternative to both hard-wired equipment and pin/sleeve type contacts, the decontactor is a highly flexible method of connecting and disconnecting electrical equipment at the press of a latch – safely. Marechal Electric brought the decontactor, the high performance industrial plug connector with integral AC21 switch, to the electrical market.
Marechal DX decontactors are designed for hazardous areas with 'de' protection mode. The Marechal DX plugs & sockets comply with the ATEX 94/9/CE Directive.
Marechal ATEX DX plugs and sockets can be used in zones 1 & 2 (gas) and zones 21 & 22 (dust). The DX decontactors are also certified according to IECEx standards.
Marechal DX ATEX Plugs & Sockets Mechanical Specifications:
Marechal IP65 plug and socket-outlet with 'de' protection mode for hazardous areas (ATEX) with integral switching device, comply with BECMA international standard.
Marechal DX ATEX Plugs & Sockets features:
Ex II2 G D Ex DE IIC
IP65 Water & dust tight
Integrated load break switch
Locking in On/Off positions by keying axis
Marechal DX ATEX Plugs & Sockets Technical Features:
Rated Current (In): 20A - 200A
Umax: 750V
Keying Positions: 12
Ambient Temperature: -25°C to +60°C
ATEX Zones: Zones 1 & 2 (gas) Zones 21 & 22 (dusts) - for all DIX
Thorne & Derrick UK are specialist distributors of Hadar Hazardous Area Lighting ranges providing expert technical guidance, site surveys, competitive quotations, ex stock delivery and a comprehensive lighting design service - this includes Zone 1 and Zone 2 (ATEX) fluorescent, recessed, portable, bulkhead, wellglass and floodlights.
Hadar Hazardous Area Lighting is a specialist manufacturer of hazardous area lighting for the oil, gas, petro-chemical, pharmaceutical, offshore and marine industries worldwide offering the design and production of lighting products for Zone 1, 2, 21 & 22, Gas and Dust - this includes ATEX and IEC Ex Explosion Proof Exe & Ex d Lighting ranges : flourescent, recessed, helideck, LED floodlight, bulkhead and well glass.
Hazardous Area Flood Lights - ATEX Certified
Zone 2 Floodlights
150W SON, 250W SON, 400W SON, 500W Tungsten Halide
Petrel hazardous area (ATEX certified) Zone 2 floodlights are extensively specified for Ex e lighting applications.
Petrel Hazardous Area Zone 2 Flood Lighting (ATEX) - Ex
Zone 2 Flood Light
Petrel hazardous area Zone 2 floodlights are made from die cast aluminium and incorporate assymetrical reflector as standard - Zone 2 floodlights can be fitted with a range of control gear suitable for lamps from 150w to 500w. Petrel ZT hazardous area Zone 2 floodlight is ATEX certified for use with SON, MBF and tungsten lamps.
Zone 2 Floodlights, Hazardous Area Lighting (ATEX) - Petrel ZT Flood Light
Benefits
Symmetrical reflector allows maximum directional light output
Graduated mounting bracket allows for consistent installation angle for multiple units
Easy re-lamping via hinged front section
Options
Sodium, metal halide, and tungsten lamp options
Other colours available
Petrel ZT150 (150W SON), ZT250 (250W SON), ZT400 (400W SON)
Petrel ZT500 (500W tungsten halide)
Features
230v 50Hz standard
-20°C to +30°C standard supply subject to ambient temperature requirements.
Tubular : SON, MBI, Tungsten. 70w to 500w Symmetrical reflector fitted to all versions (lamps not provided).
Hazardous Area Zones Classification
Zone 2 - where flammable atmosphere is not likely to occur during normal operation and if it does will only exist for short period of time, typically less than 10 hours per year.
Thorne & Derrick UK are official stockists and distributors for the Petrel Explosion Proof and Hazardous Area Lighting ranges for Zone 1 and Zone 2 lighting installations with ATEX certification – this includes hazardous area fluorescent, bulkhead, floodlight and wellglass lighting. EX Lighting Products from Petrel Hazardous Area Electrical Equipment : Ex de Well Glass, Ex d Emergency Flourescent Luminaire, Ex de Bulkhead, Ex de Zone 1 Floodlight, Zone 2 Floodlight, Ex ed Standard & Emergency Flourescent Luminaire, Zone 2 Standard & Emergency Flourescent Luminaire, Ex d Flourescent Luminaire, Zone 2 Bulkhead Luminaire, Ex ed Recessed Zone 1 Flourescent Luminaire.
Zone 2 Floodlights
ATEX Certified Hazardous Area Floodlights
Petrel hazardous area (ATEX certified) Zone 2 floodlights are extensively specified for Ex e lighting applications.
Petrel ZT150 - 150W - SON Floodlight for Zone 2 Hazardous Areas - ATEX Group II Cat 3GD
Petrel ZT Zone 2 Floodlights provide following benefits :
* Hinged lid opening for safe re-lamping in hazardous areas
* Graduated angle bracket for fast, accurate installations
* Lightweight but strong die cast aluminium floodlight
* Asymmetric reflector for maximum downward light output
Petrel Hazardous Area Zone 2 Flood Lighting (ATEX) - Ex
Zone 2 Flood Light
Petrel hazardous area Zone 2 floodlights are made from die cast aluminium and incorporate assymetrical reflector as standard - Zone 2 floodlights can be fitted with a range of control gear suitable for lamps from 150w to 500w. Petrel ZT hazardous area Zone 2 floodlight is ATEX certified for use with SON, MBF and tungsten lamps.
Hazardous Area Zones Classification
Zone 2 - where flammable atmosphere is not likely to occur during normal operation and if it does will only exist for short period of time, typically less than 10 hours per year.
ATEX Certified Lighting for Hazardous Areas Zones 1 & Zones 2
ATEX is the name given to a set of European Directives relating to Hazardous Area Electrical & Lighting Equipment Installations (Flammable Atmospheres) to avoid industrial accident or incident, this cover hazardous area lighting Zone 1 and Zone 2 installations. ATEX Directive 94/9/EC (ATEX 95), is a directive adopted by the EU under the “New Approach” strategy. The “New Approach” ATEX directive supersedes the “Old Approach” ATEX Directive, the Potentially Explosive Atmospheres Directive, 76/117/EEC – ATEX 94/9/EC (ATEX 95) facilitates free trade in the EC for hazardous area lighting and electrical equipment intended to be used in potentially explosive atmospheres. ATEX Directive 94/9/EC (ATEX 95) covers “Electrical Equipment” used in hazardous areas with potentially explosive atmospheres created by presence of gases, vapours, mists or dusts.
Thorne & Derrick UK are specialist distributors of Petrel Hazardous Area Lighting ranges providing expert technical guidance, site surveys, competitive quotations, ex stock delivery and a comprehensive lighting design service - this includes hazardous area Zone 1 and Zone 2 (ATEX) fluorescent, recessed, portable, bulkhead, wellglass and floodlights.
Petrel Hazardous Area Lighting is a specialist manufacturer of hazardous area lighting for the oil, gas, petro-chemical, pharmaceutical, offshore and marine industries worldwide offering the design and production of lighting products for Zone 1, 2, 21 & 22, Gas and Dust - this includes ATEX and IEC Ex Explosion Proof Exe & Ex d Lighting ranges : fluorescent, recessed, helideck, LED floodlight, bulkhead and well glass.
Marechal SPeX Single Pole Power Connector
Zone 1 & Zone 2 Zone 21, Zone 22
680 Amp IP65/IP66 Water & Dust-tight
Marechal Hazardous Area Plugs & Sockets
1000V a.c. / 1500V d.c. single pole, 6800A ‘e' increased safety Marechal SPeX plug and socket power connector enables the user to connect and disconnect heavy duty equipment simply and safely in hazardous area zones 1, 2, 21 and 22.
Designed for use in hazardous areas the Marechal SPeX plug and socket assembly is ATEX 94/9/CE approved for zones 1 & 2 (gas) and zones 21 & 22 (dust). Marechal SPeX offers automatic IP66/IP67 ingress protection rating as soon as the plug is inserted into the socket. Electromechanical interlocking is provided via a microswitch (which opens and closes all phases simultaneously) to protect the user and to prevent electrical destabilisation of equipment.
The Marechal casing is manufactured in glassfibre-reinforced polyester which affords excellent mechanical protection (IK08) and resistance to UV and chemical agents. Typical applications include mobile gensets, ship-to-shore supplies, mines, offshore platforms etc.
The incorrect mating of phases is mechanically impossible. Furthermore colour-coding enables a visual check.
Marechal SPeX Single Pole Power Connector
Marechal SPeX - EX ATEX Hazardous Area Plug, Socket Power Connector
Enhanced protection mode « e »
Compliant with ATEX 94/9/CE Directive
Zones 1 and 2 (gas) and zones 21 and 22 (dust)
Up to 680 A
Up to 1000 V a.c.
Interlock switch system via pilot contacts, synchronized connection and disconnection for all phasesMechanical keying system with 5 positions to discriminate between phases
Visual identification of phases with standard colour codes
Automatically IP65 dust and watertight
IK08 shock resistant GRP casings
Resistant to temperature changes: -40 °C to +60 °C
Marechal DS range of industrial power supply and motor connection plugs and sockets provide low voltage distribution, 30amps-250amps. Marechal DS range industrial plugs are the quality standard for manufacturing industry providing the following benefits compliant with International Standard IEC60309-1 and European Standard EN60309-1 (Plugs & Sockets Outlets for Industrial Purposes).
Marechal DS Power Supply and Motor Connection Plugs and Sockets
30amp-250amp current ratings for plugs and sockets
500v-1000v a.c. rated plugs and sockets
IP54/IP55 water and dust tight plug assemblies (IP66/IP67 available)
AC-22 / AC-23 load breaking capability
GRP casings, chemical and IK08 shock resistant
Metal casings, corrosion resistant, IK09 shock resistant
Resistant to temperature changes -40 to +60 Degrees Celsius
Equipped with silver-nickel butt contacts for lifetime reliability
Typical Marechal DS Industrial Plugs Applications - power supply to motor and pump connections, heavy industry, mines and quarries, ship to shore plug connections, gensets, power supply to production lines and manufacturing operations. Marechal DS plugs and sockets range of decontactors is supported by a full line of wall mounting sockets, inclined sockets, coupler sockets, wall mounting appliance inlets and inclined appliance inlets.
Marechal DS Plugs & Sockets Decontactors - The Range
Marechal DS1 Plugs - 30amp
Marechal DS3 Plugs - 50am
Marechal DS6 Plugs - 90amp
Marechal DS9 Plugs - 150amp
Marechal DS2 Plugs - 250amp
Marechal Electric pioneered the use of high performance, silver-nickel butt contacts in electrical plug and socket systems (decontactors), which are now available for applications from simple compact multi-pin to heavy duty 600A plug connections. Marechal technology is used across a range of demanding environments such as the food and drink, nuclear power, heavy industry, infrastructure and ATEX hazardous area sectors. Marechal decontactors are an effective alternative to both hard-wired equipment and pin/sleeve type contacts, the decontactor is a highly flexible method of connecting and disconnecting electrical equipment at the press of a latch – safely. Marechal Electric brought the decontactor, the high performance industrial plug connector with integral AC21 switch, to the electrical market.
Marechal DX decontactors are designed for hazardous areas with 'de' protection mode. The Marechal DX plugs & sockets comply with the ATEX 94/9/CE Directive.
Marechal ATEX DX plugs and sockets can be used in zones 1 & 2 (gas) and zones 21 & 22 (dust). The DX decontactors are also certified according to IECEx standards.
Marechal DX ATEX Plugs & Sockets Mechanical Specifications:
Marechal IP65 plug and socket-outlet with 'de' protection mode for hazardous areas (ATEX) with integral switching device, comply with BECMA international standard.
Marechal DX ATEX Plugs & Sockets features:
Ex II2 G D Ex DE IIC
IP65 Water & dust tight
Integrated load break switch
Locking in On/Off positions by keying axis
Marechal DX ATEX Plugs & Sockets Technical Features:
Rated Current (In): 20A - 200A
Umax: 750V
Keying Positions: 12
Ambient Temperature: -25°C to +60°C
ATEX Zones: Zones 1 & 2 (gas) Zones 21 & 22 (dusts) - for all DIX
T&D are distributors for the FEAM range of Hazardous Area Lighting for installation in potentially explosive atmospheres - FEAM lighting is specified for hazardous areas Zone 1 and Zone 2 (Gases) with international certifications according to ATEX, Inmetro, GOST-R, GOST-K, IECEx and CE.
Isolation Procedures for Safe Working on Electrical Systems and Equipment by the JIB | solation Procedures for Safe Working on Electrical Systems and Equipment
This chart shows the safe isolation procedure that you should use when working on electrical systems and equipment.
You'll receive a printed copy of this from your Training Provider, but it's also here as a handy reference to keep electronically.
THE RULES OF SAFE ISOLATION ARE:
Obtain permission to start work (a Permit may be required in some situations)
Identify the source(s) of supply using an approved voltage indicator or test lamp
Prove that the approved voltage indicator or test lamp is functioning correctly
Isolate the supply(s)
Secure the isolation
Prove the system/equipment is DEAD using an approved voltage indicator or test lamp
Prove that the approved voltage indicator or test lamp is functioning correctly
Put up warning signs to tell other people that the electrical installation has been isolated
Once the system/equipment is proved DEAD, work can begin
Uploaded by THORNE & DERRICK LV HV Jointing, Earthing, Substation & Electrical Eqpt | Explosive Atmosphere Experts & ATEX IECEx.
THORNE & DERRICK based in the UK are international distributors of LV, MV & HV Cable Installation, Jointing, Substation & Electrical Equipment.
Since 1985, T&D have established an international reputation based on SERVICE | INTEGRITY | TRUST.
Contact us for 3M, ABB, Alroc, AN Wallis, CATU, Cembre, Centriforce, CMP, CSD, Elastimold, Ellis Patents, Emtelle, Euromold, Filoform , Furse, Lucy Electric & Zodion, Nexans, Pfisterer, Polypipe, Prysmian, Roxtec, Sicame, WT Henley.
DevOps and Testing slides at DASA ConnectKari Kakkonen
My and Rik Marselis slides at 30.5.2024 DASA Connect conference. We discuss about what is testing, then what is agile testing and finally what is Testing in DevOps. Finally we had lovely workshop with the participants trying to find out different ways to think about quality and testing in different parts of the DevOps infinity loop.
Generative AI Deep Dive: Advancing from Proof of Concept to ProductionAggregage
Join Maher Hanafi, VP of Engineering at Betterworks, in this new session where he'll share a practical framework to transform Gen AI prototypes into impactful products! He'll delve into the complexities of data collection and management, model selection and optimization, and ensuring security, scalability, and responsible use.
How to Get CNIC Information System with Paksim Ga.pptxdanishmna97
Pakdata Cf is a groundbreaking system designed to streamline and facilitate access to CNIC information. This innovative platform leverages advanced technology to provide users with efficient and secure access to their CNIC details.
Goodbye Windows 11: Make Way for Nitrux Linux 3.5.0!SOFTTECHHUB
As the digital landscape continually evolves, operating systems play a critical role in shaping user experiences and productivity. The launch of Nitrux Linux 3.5.0 marks a significant milestone, offering a robust alternative to traditional systems such as Windows 11. This article delves into the essence of Nitrux Linux 3.5.0, exploring its unique features, advantages, and how it stands as a compelling choice for both casual users and tech enthusiasts.
20 Comprehensive Checklist of Designing and Developing a WebsitePixlogix Infotech
Dive into the world of Website Designing and Developing with Pixlogix! Looking to create a stunning online presence? Look no further! Our comprehensive checklist covers everything you need to know to craft a website that stands out. From user-friendly design to seamless functionality, we've got you covered. Don't miss out on this invaluable resource! Check out our checklist now at Pixlogix and start your journey towards a captivating online presence today.
A tale of scale & speed: How the US Navy is enabling software delivery from l...sonjaschweigert1
Rapid and secure feature delivery is a goal across every application team and every branch of the DoD. The Navy’s DevSecOps platform, Party Barge, has achieved:
- Reduction in onboarding time from 5 weeks to 1 day
- Improved developer experience and productivity through actionable findings and reduction of false positives
- Maintenance of superior security standards and inherent policy enforcement with Authorization to Operate (ATO)
Development teams can ship efficiently and ensure applications are cyber ready for Navy Authorizing Officials (AOs). In this webinar, Sigma Defense and Anchore will give attendees a look behind the scenes and demo secure pipeline automation and security artifacts that speed up application ATO and time to production.
We will cover:
- How to remove silos in DevSecOps
- How to build efficient development pipeline roles and component templates
- How to deliver security artifacts that matter for ATO’s (SBOMs, vulnerability reports, and policy evidence)
- How to streamline operations with automated policy checks on container images
Essentials of Automations: The Art of Triggers and Actions in FMESafe Software
In this second installment of our Essentials of Automations webinar series, we’ll explore the landscape of triggers and actions, guiding you through the nuances of authoring and adapting workspaces for seamless automations. Gain an understanding of the full spectrum of triggers and actions available in FME, empowering you to enhance your workspaces for efficient automation.
We’ll kick things off by showcasing the most commonly used event-based triggers, introducing you to various automation workflows like manual triggers, schedules, directory watchers, and more. Plus, see how these elements play out in real scenarios.
Whether you’re tweaking your current setup or building from the ground up, this session will arm you with the tools and insights needed to transform your FME usage into a powerhouse of productivity. Join us to discover effective strategies that simplify complex processes, enhancing your productivity and transforming your data management practices with FME. Let’s turn complexity into clarity and make your workspaces work wonders!
Unlocking Productivity: Leveraging the Potential of Copilot in Microsoft 365, a presentation by Christoforos Vlachos, Senior Solutions Manager – Modern Workplace, Uni Systems
GraphSummit Singapore | The Future of Agility: Supercharging Digital Transfor...Neo4j
Leonard Jayamohan, Partner & Generative AI Lead, Deloitte
This keynote will reveal how Deloitte leverages Neo4j’s graph power for groundbreaking digital twin solutions, achieving a staggering 100x performance boost. Discover the essential role knowledge graphs play in successful generative AI implementations. Plus, get an exclusive look at an innovative Neo4j + Generative AI solution Deloitte is developing in-house.
GDG Cloud Southlake #33: Boule & Rebala: Effective AppSec in SDLC using Deplo...James Anderson
Effective Application Security in Software Delivery lifecycle using Deployment Firewall and DBOM
The modern software delivery process (or the CI/CD process) includes many tools, distributed teams, open-source code, and cloud platforms. Constant focus on speed to release software to market, along with the traditional slow and manual security checks has caused gaps in continuous security as an important piece in the software supply chain. Today organizations feel more susceptible to external and internal cyber threats due to the vast attack surface in their applications supply chain and the lack of end-to-end governance and risk management.
The software team must secure its software delivery process to avoid vulnerability and security breaches. This needs to be achieved with existing tool chains and without extensive rework of the delivery processes. This talk will present strategies and techniques for providing visibility into the true risk of the existing vulnerabilities, preventing the introduction of security issues in the software, resolving vulnerabilities in production environments quickly, and capturing the deployment bill of materials (DBOM).
Speakers:
Bob Boule
Robert Boule is a technology enthusiast with PASSION for technology and making things work along with a knack for helping others understand how things work. He comes with around 20 years of solution engineering experience in application security, software continuous delivery, and SaaS platforms. He is known for his dynamic presentations in CI/CD and application security integrated in software delivery lifecycle.
Gopinath Rebala
Gopinath Rebala is the CTO of OpsMx, where he has overall responsibility for the machine learning and data processing architectures for Secure Software Delivery. Gopi also has a strong connection with our customers, leading design and architecture for strategic implementations. Gopi is a frequent speaker and well-known leader in continuous delivery and integrating security into software delivery.
Why You Should Replace Windows 11 with Nitrux Linux 3.5.0 for enhanced perfor...SOFTTECHHUB
The choice of an operating system plays a pivotal role in shaping our computing experience. For decades, Microsoft's Windows has dominated the market, offering a familiar and widely adopted platform for personal and professional use. However, as technological advancements continue to push the boundaries of innovation, alternative operating systems have emerged, challenging the status quo and offering users a fresh perspective on computing.
One such alternative that has garnered significant attention and acclaim is Nitrux Linux 3.5.0, a sleek, powerful, and user-friendly Linux distribution that promises to redefine the way we interact with our devices. With its focus on performance, security, and customization, Nitrux Linux presents a compelling case for those seeking to break free from the constraints of proprietary software and embrace the freedom and flexibility of open-source computing.
Enchancing adoption of Open Source Libraries. A case study on Albumentations.AIVladimir Iglovikov, Ph.D.
Presented by Vladimir Iglovikov:
- https://www.linkedin.com/in/iglovikov/
- https://x.com/viglovikov
- https://www.instagram.com/ternaus/
This presentation delves into the journey of Albumentations.ai, a highly successful open-source library for data augmentation.
Created out of a necessity for superior performance in Kaggle competitions, Albumentations has grown to become a widely used tool among data scientists and machine learning practitioners.
This case study covers various aspects, including:
People: The contributors and community that have supported Albumentations.
Metrics: The success indicators such as downloads, daily active users, GitHub stars, and financial contributions.
Challenges: The hurdles in monetizing open-source projects and measuring user engagement.
Development Practices: Best practices for creating, maintaining, and scaling open-source libraries, including code hygiene, CI/CD, and fast iteration.
Community Building: Strategies for making adoption easy, iterating quickly, and fostering a vibrant, engaged community.
Marketing: Both online and offline marketing tactics, focusing on real, impactful interactions and collaborations.
Mental Health: Maintaining balance and not feeling pressured by user demands.
Key insights include the importance of automation, making the adoption process seamless, and leveraging offline interactions for marketing. The presentation also emphasizes the need for continuous small improvements and building a friendly, inclusive community that contributes to the project's growth.
Vladimir Iglovikov brings his extensive experience as a Kaggle Grandmaster, ex-Staff ML Engineer at Lyft, sharing valuable lessons and practical advice for anyone looking to enhance the adoption of their open-source projects.
Explore more about Albumentations and join the community at:
GitHub: https://github.com/albumentations-team/albumentations
Website: https://albumentations.ai/
LinkedIn: https://www.linkedin.com/company/100504475
Twitter: https://x.com/albumentations
UiPath Test Automation using UiPath Test Suite series, part 5DianaGray10
Welcome to UiPath Test Automation using UiPath Test Suite series part 5. In this session, we will cover CI/CD with devops.
Topics covered:
CI/CD with in UiPath
End-to-end overview of CI/CD pipeline with Azure devops
Speaker:
Lyndsey Byblow, Test Suite Sales Engineer @ UiPath, Inc.
In his public lecture, Christian Timmerer provides insights into the fascinating history of video streaming, starting from its humble beginnings before YouTube to the groundbreaking technologies that now dominate platforms like Netflix and ORF ON. Timmerer also presents provocative contributions of his own that have significantly influenced the industry. He concludes by looking at future challenges and invites the audience to join in a discussion.
Sudheer Mechineni, Head of Application Frameworks, Standard Chartered Bank
Discover how Standard Chartered Bank harnessed the power of Neo4j to transform complex data access challenges into a dynamic, scalable graph database solution. This keynote will cover their journey from initial adoption to deploying a fully automated, enterprise-grade causal cluster, highlighting key strategies for modelling organisational changes and ensuring robust disaster recovery. Learn how these innovations have not only enhanced Standard Chartered Bank’s data infrastructure but also positioned them as pioneers in the banking sector’s adoption of graph technology.
Unlock the Future of Search with MongoDB Atlas_ Vector Search Unleashed.pdfMalak Abu Hammad
Discover how MongoDB Atlas and vector search technology can revolutionize your application's search capabilities. This comprehensive presentation covers:
* What is Vector Search?
* Importance and benefits of vector search
* Practical use cases across various industries
* Step-by-step implementation guide
* Live demos with code snippets
* Enhancing LLM capabilities with vector search
* Best practices and optimization strategies
Perfect for developers, AI enthusiasts, and tech leaders. Learn how to leverage MongoDB Atlas to deliver highly relevant, context-aware search results, transforming your data retrieval process. Stay ahead in tech innovation and maximize the potential of your applications.
#MongoDB #VectorSearch #AI #SemanticSearch #TechInnovation #DataScience #LLM #MachineLearning #SearchTechnology
Removing Uninteresting Bytes in Software FuzzingAftab Hussain
Imagine a world where software fuzzing, the process of mutating bytes in test seeds to uncover hidden and erroneous program behaviors, becomes faster and more effective. A lot depends on the initial seeds, which can significantly dictate the trajectory of a fuzzing campaign, particularly in terms of how long it takes to uncover interesting behaviour in your code. We introduce DIAR, a technique designed to speedup fuzzing campaigns by pinpointing and eliminating those uninteresting bytes in the seeds. Picture this: instead of wasting valuable resources on meaningless mutations in large, bloated seeds, DIAR removes the unnecessary bytes, streamlining the entire process.
In this work, we equipped AFL, a popular fuzzer, with DIAR and examined two critical Linux libraries -- Libxml's xmllint, a tool for parsing xml documents, and Binutil's readelf, an essential debugging and security analysis command-line tool used to display detailed information about ELF (Executable and Linkable Format). Our preliminary results show that AFL+DIAR does not only discover new paths more quickly but also achieves higher coverage overall. This work thus showcases how starting with lean and optimized seeds can lead to faster, more comprehensive fuzzing campaigns -- and DIAR helps you find such seeds.
- These are slides of the talk given at IEEE International Conference on Software Testing Verification and Validation Workshop, ICSTW 2022.
UiPath Test Automation using UiPath Test Suite series, part 6DianaGray10
Welcome to UiPath Test Automation using UiPath Test Suite series part 6. In this session, we will cover Test Automation with generative AI and Open AI.
UiPath Test Automation with generative AI and Open AI webinar offers an in-depth exploration of leveraging cutting-edge technologies for test automation within the UiPath platform. Attendees will delve into the integration of generative AI, a test automation solution, with Open AI advanced natural language processing capabilities.
Throughout the session, participants will discover how this synergy empowers testers to automate repetitive tasks, enhance testing accuracy, and expedite the software testing life cycle. Topics covered include the seamless integration process, practical use cases, and the benefits of harnessing AI-driven automation for UiPath testing initiatives. By attending this webinar, testers, and automation professionals can gain valuable insights into harnessing the power of AI to optimize their test automation workflows within the UiPath ecosystem, ultimately driving efficiency and quality in software development processes.
What will you get from this session?
1. Insights into integrating generative AI.
2. Understanding how this integration enhances test automation within the UiPath platform
3. Practical demonstrations
4. Exploration of real-world use cases illustrating the benefits of AI-driven test automation for UiPath
Topics covered:
What is generative AI
Test Automation with generative AI and Open AI.
UiPath integration with generative AI
Speaker:
Deepak Rai, Automation Practice Lead, Boundaryless Group and UiPath MVP
UiPath Test Automation using UiPath Test Suite series, part 6
Stahl T-LUX 6035 Tubular Light Fittings - ATEX Zone 1 Zone 2 Hazardous Area
1. E2
E2
E2
E2
E2
E2
E2
E2
E2
E2
E2
E2
E2
E2
Tubular Light Fittings for Fluorescent Lamps
Series T-LUX 6035
www.stahl.de Lighting E2/1 2013-08-14·EK00·III·en
Series T-LUX 6035 E2
12665E00
WebCode 6035A
> Pendant, wall mounting or
bulkhead fitting options
> 1- or 2-lamp version
– 18 W
– 36 W
– 58 W
> Aluminium enclosure,
borosilicate glass tube
> Degree of protection IP68
The light Series T-LUX 6035 fittings are ideal for use on ships, in
sewage and treatment plants, pumping stations water collecting
tanks and inspection pits. They can be used for normal lighting as
well as for group or centrally supplied emergency lights.
ATEX / IECEx
Zone 0 1 2 20 21 22
For use in x x x x
2. Tubular Light Fittings for Fluorescent Lamps
Series T-LUX 6035
Selection Table
Version
Lamps
Explosion group
Temperature class
Electronic ballast
Order number Weight
without external
reflector
with external
reflector
40 °C
55 °C
TO max at
Ta = 55 °C
Ta = 40 °C
Ta = 55 °C
TO max = 55 °C
kg
Tubular Light Fittings
for Fluorescent
Lamps
Series T-LUX 6035
2 x
18 W
IIC T6 2) T5 85 °C T6 T5 95 °C 1 channel EB 6035/12522-8010 9.700
IIC T6 2) T5 85 °C T6 T5 95 °C Magnetic
ballast
compensated
6035/12522-4010 9.700
2 x
36 W
IIB T6 T5 100 °C T6 T6 80 °C 1 channel EB 6035/13542-8010 15.300
IIB+H2 T6 T5 100 °C T6 T6 80 °C Magnetic
ballast
compensated
6035/13542-2010 15.300
2 x
58 W
IIB T6 T6 80 °C T6 T5 95 °C 1 channel EB 6035/14562-8010 18.200
IIB T6 T6 80 °C T6 T5 95 °C Magnetic
ballast
compensated
6035/14562-2010 18.200
Note 2) with magnetic ballast
Explosion Protection
Global (IECEx)
Gas and dust IECEx LCI 07.0002
Ex d IIB T4, T5 or T6
Ex tD A21
see selection table
Europe (ATEX)
Gas and dust LCIE 06 ATEX 6104
E 2 II G Ex d IIC/B T1) IIB = 36 W / 58 W IIC = 18 W
E II 2 D Ex tD A21
see selection table
Certifications and certificates
Certificates IECEx, ATEX, Serbia (SRPS), Belarus (operating authorisation)
Technical Data
Electrical data
Rated voltage ECG: 220 ... 240 V ± 10 %, 50/60 Hz, cos φ ) 0.95
Magnetic ballast: 230 or 240 V + 6 % - 10 %, 50 Hz, cos φ ) 0.9 (compensated)
Rated current
Luminous Characteristics
1 x 18 W 2 x 18 W 1 x 36 W 2 x 36 W 1 x 58 W 2 x 58 W
0.1 A 0.17 A 0.17 A 0.32 A 0.26 A 0.52 A
Lamps 1 x 18 W ; 2 x 18 W; 1 x 36 W; 2 x 36 W, 1 x 58 W, 2 x 58 W
Two-pin fluorescent lamps d 26 mm, socket G13
Measures for light
guidance
Standard: wide beam, tube sides anti-glare
Ambient conditions
Ambient temperature - 20 ... + 55 °C (6035/12 and 6035/13 Ta - 20 ... + 60 °C)
Mechanical data
Degree of protection IP66 / IP68 (10 m)
Protection class I(with internal PE connection terminal)
Cover fixing screw cap
Material
Enclosure Aluminium
Tube Borosilicate glass
Assembly / Installation
Cable gland
Standard 2 holes M20 facing each other; 1 stopping plug included in the delivery
Special 2 holes M20 add 1 hole M25 or 2 holes NPT 3/4“
metal cable gland earthing via metal adapter plates
Connection type Terminal block with spring contacts; with through-wiring option
Marking L1 + N + PE; cable cross-section max. 2 x 2.5 mm2, solid / flexible
E2/2 Lighting 2013-08-14·EK00·III·en
3. E2
E2
E2
E2
E2
E2
E2
E2
E2
E2
E2
E2
E2
E2
Tubular Light Fittings for Fluorescent Lamps
Series T-LUX 6035
Technical Data
Assembly / Installation
Mounting
Standard 3 x M8 inserts in the end caps
Special Options are: wall mounting bracket, pipe clamps or ring bolts.
Note on Mounting
When installing the light fittings care must be taken to ensure that the distance between the
opening side of the fitting and the wall, the next light fitting or other obstacles is at least one fitting
length. This is because the reflector plate must be pulled right out of thefitting when lamps are
changed.
Accessories and Spare Parts
Designation Illustration Description Art. no. Weight
kg
Bi-pin lamp G13,
light colour:
universal white 04936E00
108952 0.100
108951 0.200
108950 0.220
Fixation on flat
surface
06645E00
18 W 1350 Im
36 W 3350 Im
58 W 5200 Im
1 pair, material: stainless steel 117200 0.510
1 pair, material: zinc plated steel 117199 0.520
Pipe hanger fastening
06640E00
1 pair, material: stainless steel, 42 - 49 mm (1 1/4 - 1 1/2 ) 117196 0.690
1 pair, material: zinc plated steel, 42 - 49 mm (1 1/4 - 1 1/2 ) 117195 0.660
Fast Fixing
06643E00
1 pair, material: stainless steel 117198 0.270
1 pair, material: zinc plated steel 117197 0.280
External Reflector
12647E00
Steel reflector, varnished, 58 W 117203 0.070
Steel reflector, varnished, 36 W 117202 0.060
Steel reflector, varnished, 18 W 117201 0.050
Protective wire grid
12646E00
Steel protective wire grid, 58 W 117194 0.100
Steel protective wire grid, 36 W 117193 0.085
Steel protective wire grid, 18 W 117192 0.070
Fall prevention kit
14857E
1,20 m stainless steel chain 211866 0.145
Dimensional Drawings (all Dimensions in mm) - Subject to Alterations
06633E00
Lamps A B
18 W 745 650
36 W 1365 1260
58 W 1655 1560
150
Ø 12
89
191
85
15
12 B 77,5
Series 6035 Tubular Light Fittings
A
We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice.
The illustrations cannot be considered binding.
2013-08-14·EK00·III·en Lighting E2/3