The TD-9000T is a digital indicator for load management that supports two inputs, load (load cell) and stroke (displacement gauge).
High-speed A/D conversion of 25,000 times/sec and equipped with a 4.3-inch touchscreen monitor in DIN1/4 (92 x 92) size. While being high-end, it is a high-performance model that realizes a low price.
Waveforms during measurement can be checked in real time. Widely usable from daily monitoring to verification of processing data.
The document discusses IRD's condition monitoring technology for machines. It describes their 6600 series vibration and process monitors that meet API standards and provide vibration analysis, temperature monitoring, and data collection capabilities. The 3603 data interface unit allows connecting up to 200 monitors via RS485 and collecting data from them to transfer to host computers using Ethernet or RS232 connections. The Oliver2 software is used for long-term trending, alarm management, and vibration analysis from the collected data. IRD's systems have been selected for use by major oil and gas companies on various projects due to meeting industry standards.
This document provides an overview of the Fire-Lite MS-9200UDLS(E) Rev 2 Intelligent Addressable Fire Alarm Control Panel (FACP). It has a built-in digital alarm communicator transmitter (DACT) and supports up to 198 devices connected via its Signaling Line Circuit (SLC) loop. Key features include four onboard notification appliance circuits (NACs), an 80-character LCD display, integral DACT for central station monitoring, and compatibility with various annunciators and modules. The control panel can be programmed and monitored locally or remotely using a Windows-based PC and PS-Tools software.
Series One Safety Transmitter, Pressure and Temperature SwitchIves Equipment
The One Series Safety Transmitter is a transmitter-switch for monitoring pressure or temperature and meets the requirements of SIL 2 for random integrity at HFT = 0, SIL 3 for random integrity at HFT = 1 and SIL 3 for systematic capability. The One Series Safety Transmitter incorporates UE’s patented IAW self diagnostics, redundant and diverse signal processing and software algorithms to detect abnormalities in the process and internal faults. The design is based on a powerful microprocessor that provides an extremely fast response time for emergency shutdown situations.
Ls catalog thiet bi tu dong i s5_e_1105_dienhathe.vnDien Ha The
Khoa Học - Kỹ Thuật & Giải Trí: http://phongvan.org
Tài Liệu Khoa Học Kỹ Thuật: http://tailieukythuat.info
Thiết bị Điện Công Nghiệp - Điện Hạ Thế: http://dienhathe.org
The document discusses WEG electronic relays, including:
- RTW timing relays that switch outputs based on selected functions and times, available from 0.1 seconds to 150 hours.
- RPW monitoring relays for voltage monitoring to protect against electrical failures like phase loss and overvoltage.
- ERWT multifunction timing relays with 8 functions in a single relay adjustable from 0.1 seconds to 10 days.
- ERWM multifunction monitoring relays with 5 protection functions adjustable from 208-480V AC.
- RNW level relays for monitoring and automatic adjustment of liquid levels in reservoirs.
Understanding SWIFT Step Down DC/DC ConvertersPremier Farnell
The document introduces Texas Instruments' SWIFT DC/DC converters. It discusses the advantages and disadvantages of DC/DC converters with integrated FETs compared to other solutions. It then describes key features of SWIFT converters like synchronous switching, adjustable soft start, Eco-Mode for high efficiency at light loads, internal and external compensation options, and 180 degree out of phase switching. Finally, it provides an overview of the SWIFT product portfolio covering solutions for light load efficiency, synchronization, sequencing, memory power, and switcher pro design software.
The TD-9000T is a digital indicator for load management that supports two inputs, load (load cell) and stroke (displacement gauge).
High-speed A/D conversion of 25,000 times/sec and equipped with a 4.3-inch touchscreen monitor in DIN1/4 (92 x 92) size. While being high-end, it is a high-performance model that realizes a low price.
Waveforms during measurement can be checked in real time. Widely usable from daily monitoring to verification of processing data.
The document discusses IRD's condition monitoring technology for machines. It describes their 6600 series vibration and process monitors that meet API standards and provide vibration analysis, temperature monitoring, and data collection capabilities. The 3603 data interface unit allows connecting up to 200 monitors via RS485 and collecting data from them to transfer to host computers using Ethernet or RS232 connections. The Oliver2 software is used for long-term trending, alarm management, and vibration analysis from the collected data. IRD's systems have been selected for use by major oil and gas companies on various projects due to meeting industry standards.
This document provides an overview of the Fire-Lite MS-9200UDLS(E) Rev 2 Intelligent Addressable Fire Alarm Control Panel (FACP). It has a built-in digital alarm communicator transmitter (DACT) and supports up to 198 devices connected via its Signaling Line Circuit (SLC) loop. Key features include four onboard notification appliance circuits (NACs), an 80-character LCD display, integral DACT for central station monitoring, and compatibility with various annunciators and modules. The control panel can be programmed and monitored locally or remotely using a Windows-based PC and PS-Tools software.
Series One Safety Transmitter, Pressure and Temperature SwitchIves Equipment
The One Series Safety Transmitter is a transmitter-switch for monitoring pressure or temperature and meets the requirements of SIL 2 for random integrity at HFT = 0, SIL 3 for random integrity at HFT = 1 and SIL 3 for systematic capability. The One Series Safety Transmitter incorporates UE’s patented IAW self diagnostics, redundant and diverse signal processing and software algorithms to detect abnormalities in the process and internal faults. The design is based on a powerful microprocessor that provides an extremely fast response time for emergency shutdown situations.
Ls catalog thiet bi tu dong i s5_e_1105_dienhathe.vnDien Ha The
Khoa Học - Kỹ Thuật & Giải Trí: http://phongvan.org
Tài Liệu Khoa Học Kỹ Thuật: http://tailieukythuat.info
Thiết bị Điện Công Nghiệp - Điện Hạ Thế: http://dienhathe.org
The document discusses WEG electronic relays, including:
- RTW timing relays that switch outputs based on selected functions and times, available from 0.1 seconds to 150 hours.
- RPW monitoring relays for voltage monitoring to protect against electrical failures like phase loss and overvoltage.
- ERWT multifunction timing relays with 8 functions in a single relay adjustable from 0.1 seconds to 10 days.
- ERWM multifunction monitoring relays with 5 protection functions adjustable from 208-480V AC.
- RNW level relays for monitoring and automatic adjustment of liquid levels in reservoirs.
Understanding SWIFT Step Down DC/DC ConvertersPremier Farnell
The document introduces Texas Instruments' SWIFT DC/DC converters. It discusses the advantages and disadvantages of DC/DC converters with integrated FETs compared to other solutions. It then describes key features of SWIFT converters like synchronous switching, adjustable soft start, Eco-Mode for high efficiency at light loads, internal and external compensation options, and 180 degree out of phase switching. Finally, it provides an overview of the SWIFT product portfolio covering solutions for light load efficiency, synchronization, sequencing, memory power, and switcher pro design software.
This certificate certifies that the PGR-8800 Series Arc Flash Monitoring System produced by Littelfuse Selco A/S has been found to comply with Det Norske Veritas' classification rules for ships and offshore standards. The system includes an arc fault protection module and sensors to detect arc flashes. It was tested for safety, environment, and electromagnetic compatibility. The certificate is valid until June 30, 2019 and the product must undergo periodic assessment to maintain the type approval.
Liquisys M CPM223/253. pH/ORP Measurement. Transmitter for analog and digital glass and ISFET sensors. Email: lam.nguyen@vietan-enviro.com HP: 0945 293292
This document describes HSDC/HRDC series isolated synchro/resolver to digital converters. The converters have built-in self-test and forced angle test modes. They require no external components and provide transformer isolation between field signals and user circuitry. The converters continuously track input angles in real-time and provide accurate digital position data at programmable resolutions up to 16 bits.
IM 42XX Series - Intelligent Monitoring System - Panel Mount. (Serial & 4-20m...Suyash Lad
"Intelligent Gas Monitoring System" product developed by me in the 'Ambetronics Engineers Pv. Ltd.' for Gas & Temperature monitoring with multiple features.
Catalog of 10" touch screen, Panel Mount, Modbus &
4-20mAmp input, having relay outputs and Serial port (Modbus) for communicating with the BMS/SCADA/DCS/Fire Panel. or any external device such as IoT devices / GSM modems.
For more details contact us at https://ambetronics.com
Magnetrol TA2 Thermal Mass Flow Meter for Flare Gas ApplicationsMiller Energy, Inc.
Low flow sensitivity means high reliability for flare gas applications. The Thermatel® TA2 thermal dispersion mass flow meter provides reliable mass flow measurement for flare gas applications to comply with monitoring requirements.
Catalog Biến tần Frenic Multi Fuji (Fuji Electric) - Beeteco.comBeeteco
Catalog Biến tần Frenic Multi Fuji - Beeteco.com
Beeteco.com là trang mua sắm trực tuyến thiết bị điện - Tự động hóa uy tín tại Việt Nam.
Chuyên cung cấp các thiết bị: Đèn báo nút nhấn, Relay, Timer, Contactor, MCCB ELCB, Biến tần, Van, Thiết bị cảm biến, phụ kiện tủ điện, .... Từ các thương hiệu hàng đầu trên thế giới.
www.beeteco.com @ Công ty TNHH TM KT ASTER
Số 7 Đại Lộ Độc Lập, KCN Sóng Thần 1, P. Dĩ An, Tx. Dĩ An, Bình Dương
www.facebook.com/beeteco
Tel: 0650 3617 012
DĐ: 0904 676 925
Datasheet Fluke Hydra Series III. Hubungi PT. Siwali Swantika 021-45850618PT. Siwali Swantika
The Fluke 2638A is an expandable, precision data acquisition system and digital multimeter. It features high accuracy measurements, thermocouple and resistance temperature detector (RTD) inputs, and can scale from 22 to 66 input channels. The 2638A provides real-time graphing and data analysis capabilities without needing a PC. It has multiple connectivity, storage, and security features for industrial data collection applications.
The document provides information about the ULTRAFLOW® 54 flow sensor, which uses ultrasonic measuring techniques to measure flow volume and is designed for use in heating installations where water is used as the heat-bearing medium; it has a compact design with circuits collected on a single board for high accuracy and reliability, and measures flow using bidirectional ultrasonic technique to determine the time difference between ultrasonic signals travelling with and against the flow.
Catalog Frenic-HVAC (Fuji Electric): Biến tần Frenic-HVAC
Beeteco.com là trang mua sắm trực tuyến thiết bị điện - Tự động hóa uy tín tại Việt Nam.
Chuyên cung cấp các thiết bị: Đèn báo nút nhấn, Relay, Timer, Contactor, MCCB ELCB, Biến tần, Van, Thiết bị cảm biến, phụ kiện tủ điện, .... Từ các thương hiệu hàng đầu trên thế giới.
www.beeteco.com @ Công ty TNHH TM KT ASTER
Số 7 Đại Lộ Độc Lập, KCN Sóng Thần 1, P. Dĩ An, Tx. Dĩ An, Bình Dương
www.facebook.com/beeteco
Tel: 0650 3617 012
DĐ: 0904 676 925
Brosur Fluke 8845A. Brosur Fluke 8846A. Brosur Fluke 8808A. Informasi lebih detail hubungi PT. Siwali Swantika, Jakarta Office : 021-45850618 atau Surabaya Office : 031-8421264
Light weight with ceramic wool insulation (instead of Brick insulation). The outer casting is made of double
walled thick PCRC sheet, duly painted with attractive stove enamel.
The Siemens Ultrasonic Level Transmitter LUT400 arrangement controllers are conservative single point long-go ultrasonic controllers for constant level or volume estimation of fluids slurries and solids and high precision observing of open channel stream Ultrasonic Level Transmitter.The SITRANS LUT400 comes in three distinct models relying upon the application, level of execution and usefulness required.see more:- www.siemenstransmitter.com
The PML-1000 is an AC line powered panel meter for measuring LVDT/RVDT sensors. It features a large 5-digit LED display, 0-10VDC and 4-20mA outputs, optional RS422/485 communications, and easy calibration. The meter provides functions like minimum, maximum, average readings and is compatible with various Measurement Specialties sensors.
The LVM-110 is a compact, low-cost OEM signal conditioner that provides voltage outputs for LVDT/RVDT sensors. It has selectable gain, output options, and excitation frequencies. It operates on ±12 or ±15VDC and offers precision conditioning of transducer signals with low noise and adjustable zero and span.
The document describes an analog servo drive called the AZBE60A8. It is designed to drive brushless and brushed DC motors at high switching frequencies. Key specifications include a peak current of 60A, continuous current of 30A, and operating voltage range of 10-80VDC. It has protection against overvoltage, undervoltage, overcurrent and more. It can utilize encoder, hall sensor, or tachometer feedback and supports various motor and operation modes.
The document describes a One Series Safety Transmitter with Dual Seal that can improve process safety compliance. It has built-in logic solving capabilities that eliminate the need for a separate safety PLC and switch, reducing costs. It can comply with international safety standards, is certified for SIL 2 safety instrumented systems and capable of SIL 3. Installing it can save up to 80% of installation time and up to 82% of equipment costs compared to separate process transmitters and safety systems.
The AZBE40A8 is a PWM servo drive designed to drive brushless and brushed DC motors. It can provide a peak current of 40A and continuous current of 20A, with a supply voltage range of 10-80VDC. The drive is fully protected against over-voltage, under-voltage, over-current and other faults. It supports various feedback and operation modes including encoder velocity control.
The most accurate and flexible temperature data acquisition system for the fa...Fluke Calibration
Data acquisition in the factory or temperature calibration in the lab? The 1586A Super-DAQ lets you do both! The 1586A is a versatile instrument that can be easily configured for use in the factory or benchtop. It features excellent temperature measurement accuracy, four modes of operation, real-time graphing of up to four channels simultaneously, data portability and security, and the capability to control Fluke Calibration dry-wells and baths for automated calibration routines.
This document discusses open data, including what it is, its impacts, and economic value. It provides examples of open data portals and applications using open data for weather, agriculture, mapping, and more. Open data governance and standards in Ireland are also covered, such as the open data licence, metadata standards, and APIs. Finally, tools for visualizing and working with open data are listed, along with open data competitions and events.
This certificate certifies that the PGR-8800 Series Arc Flash Monitoring System produced by Littelfuse Selco A/S has been found to comply with Det Norske Veritas' classification rules for ships and offshore standards. The system includes an arc fault protection module and sensors to detect arc flashes. It was tested for safety, environment, and electromagnetic compatibility. The certificate is valid until June 30, 2019 and the product must undergo periodic assessment to maintain the type approval.
Liquisys M CPM223/253. pH/ORP Measurement. Transmitter for analog and digital glass and ISFET sensors. Email: lam.nguyen@vietan-enviro.com HP: 0945 293292
This document describes HSDC/HRDC series isolated synchro/resolver to digital converters. The converters have built-in self-test and forced angle test modes. They require no external components and provide transformer isolation between field signals and user circuitry. The converters continuously track input angles in real-time and provide accurate digital position data at programmable resolutions up to 16 bits.
IM 42XX Series - Intelligent Monitoring System - Panel Mount. (Serial & 4-20m...Suyash Lad
"Intelligent Gas Monitoring System" product developed by me in the 'Ambetronics Engineers Pv. Ltd.' for Gas & Temperature monitoring with multiple features.
Catalog of 10" touch screen, Panel Mount, Modbus &
4-20mAmp input, having relay outputs and Serial port (Modbus) for communicating with the BMS/SCADA/DCS/Fire Panel. or any external device such as IoT devices / GSM modems.
For more details contact us at https://ambetronics.com
Magnetrol TA2 Thermal Mass Flow Meter for Flare Gas ApplicationsMiller Energy, Inc.
Low flow sensitivity means high reliability for flare gas applications. The Thermatel® TA2 thermal dispersion mass flow meter provides reliable mass flow measurement for flare gas applications to comply with monitoring requirements.
Catalog Biến tần Frenic Multi Fuji (Fuji Electric) - Beeteco.comBeeteco
Catalog Biến tần Frenic Multi Fuji - Beeteco.com
Beeteco.com là trang mua sắm trực tuyến thiết bị điện - Tự động hóa uy tín tại Việt Nam.
Chuyên cung cấp các thiết bị: Đèn báo nút nhấn, Relay, Timer, Contactor, MCCB ELCB, Biến tần, Van, Thiết bị cảm biến, phụ kiện tủ điện, .... Từ các thương hiệu hàng đầu trên thế giới.
www.beeteco.com @ Công ty TNHH TM KT ASTER
Số 7 Đại Lộ Độc Lập, KCN Sóng Thần 1, P. Dĩ An, Tx. Dĩ An, Bình Dương
www.facebook.com/beeteco
Tel: 0650 3617 012
DĐ: 0904 676 925
Datasheet Fluke Hydra Series III. Hubungi PT. Siwali Swantika 021-45850618PT. Siwali Swantika
The Fluke 2638A is an expandable, precision data acquisition system and digital multimeter. It features high accuracy measurements, thermocouple and resistance temperature detector (RTD) inputs, and can scale from 22 to 66 input channels. The 2638A provides real-time graphing and data analysis capabilities without needing a PC. It has multiple connectivity, storage, and security features for industrial data collection applications.
The document provides information about the ULTRAFLOW® 54 flow sensor, which uses ultrasonic measuring techniques to measure flow volume and is designed for use in heating installations where water is used as the heat-bearing medium; it has a compact design with circuits collected on a single board for high accuracy and reliability, and measures flow using bidirectional ultrasonic technique to determine the time difference between ultrasonic signals travelling with and against the flow.
Catalog Frenic-HVAC (Fuji Electric): Biến tần Frenic-HVAC
Beeteco.com là trang mua sắm trực tuyến thiết bị điện - Tự động hóa uy tín tại Việt Nam.
Chuyên cung cấp các thiết bị: Đèn báo nút nhấn, Relay, Timer, Contactor, MCCB ELCB, Biến tần, Van, Thiết bị cảm biến, phụ kiện tủ điện, .... Từ các thương hiệu hàng đầu trên thế giới.
www.beeteco.com @ Công ty TNHH TM KT ASTER
Số 7 Đại Lộ Độc Lập, KCN Sóng Thần 1, P. Dĩ An, Tx. Dĩ An, Bình Dương
www.facebook.com/beeteco
Tel: 0650 3617 012
DĐ: 0904 676 925
Brosur Fluke 8845A. Brosur Fluke 8846A. Brosur Fluke 8808A. Informasi lebih detail hubungi PT. Siwali Swantika, Jakarta Office : 021-45850618 atau Surabaya Office : 031-8421264
Light weight with ceramic wool insulation (instead of Brick insulation). The outer casting is made of double
walled thick PCRC sheet, duly painted with attractive stove enamel.
The Siemens Ultrasonic Level Transmitter LUT400 arrangement controllers are conservative single point long-go ultrasonic controllers for constant level or volume estimation of fluids slurries and solids and high precision observing of open channel stream Ultrasonic Level Transmitter.The SITRANS LUT400 comes in three distinct models relying upon the application, level of execution and usefulness required.see more:- www.siemenstransmitter.com
The PML-1000 is an AC line powered panel meter for measuring LVDT/RVDT sensors. It features a large 5-digit LED display, 0-10VDC and 4-20mA outputs, optional RS422/485 communications, and easy calibration. The meter provides functions like minimum, maximum, average readings and is compatible with various Measurement Specialties sensors.
The LVM-110 is a compact, low-cost OEM signal conditioner that provides voltage outputs for LVDT/RVDT sensors. It has selectable gain, output options, and excitation frequencies. It operates on ±12 or ±15VDC and offers precision conditioning of transducer signals with low noise and adjustable zero and span.
The document describes an analog servo drive called the AZBE60A8. It is designed to drive brushless and brushed DC motors at high switching frequencies. Key specifications include a peak current of 60A, continuous current of 30A, and operating voltage range of 10-80VDC. It has protection against overvoltage, undervoltage, overcurrent and more. It can utilize encoder, hall sensor, or tachometer feedback and supports various motor and operation modes.
The document describes a One Series Safety Transmitter with Dual Seal that can improve process safety compliance. It has built-in logic solving capabilities that eliminate the need for a separate safety PLC and switch, reducing costs. It can comply with international safety standards, is certified for SIL 2 safety instrumented systems and capable of SIL 3. Installing it can save up to 80% of installation time and up to 82% of equipment costs compared to separate process transmitters and safety systems.
The AZBE40A8 is a PWM servo drive designed to drive brushless and brushed DC motors. It can provide a peak current of 40A and continuous current of 20A, with a supply voltage range of 10-80VDC. The drive is fully protected against over-voltage, under-voltage, over-current and other faults. It supports various feedback and operation modes including encoder velocity control.
The most accurate and flexible temperature data acquisition system for the fa...Fluke Calibration
Data acquisition in the factory or temperature calibration in the lab? The 1586A Super-DAQ lets you do both! The 1586A is a versatile instrument that can be easily configured for use in the factory or benchtop. It features excellent temperature measurement accuracy, four modes of operation, real-time graphing of up to four channels simultaneously, data portability and security, and the capability to control Fluke Calibration dry-wells and baths for automated calibration routines.
This document discusses open data, including what it is, its impacts, and economic value. It provides examples of open data portals and applications using open data for weather, agriculture, mapping, and more. Open data governance and standards in Ireland are also covered, such as the open data licence, metadata standards, and APIs. Finally, tools for visualizing and working with open data are listed, along with open data competitions and events.
Open Source & Open Data Session report from imaGIne 2014 ConferenceGSDI Association
Session report from the imaGIne 2014 Conference held in Berlin, Germany, in October 2014. Session was chaired by Dr. Gabor Remetey-Fulopp, of HUNAGI, who were co-organisers for Session 8C1.
The barometric pressure sensor is one of Sutron’s most commonly used sensors, and is typically used in weather and airport stations. This guide will describe the proper method of connecting the sensor with the 9210 datalogger.
R A Longhorn Presentation at Taiwan Open Data Forum, Taipei, 9 July 2014GSDI Association
Big Data Meets Open Data: Challenges and Issues presentation of Roger Longhorn, Operations & Communications Manager, GSDI Association, delivered at the Taiwan Open Data Forum, 9 July 2014 in Taipei
This servo drive operates in torque, velocity, or position mode. It features a CANopen interface, configurable digital and analog inputs/outputs, and supports various feedback types including encoders. The drive complies with relevant safety standards and has a peak current of 30A and continuous current of 15A.
The STM is an integrated step motor and drive device that combines a step motor and drive electronics into a single unit. This offers space, wiring, and cost savings over separate motor and drive solutions. The STM provides various control modes including pulse and direction, velocity control, and execution of programmed motion sequences. Models are available with different communications interfaces like RS-232, RS-485, and CANopen.
This document provides specifications for the DigiFlex® PerformanceTM Servo Drive DPCANIS-060A800. It is a digital servo drive designed to drive brushed and brushless servomotors in torque, velocity, or position mode. It features a CANopen interface, configurable I/O, and is compliant with various safety standards including CE and RoHS. The drive provides up to 60A of peak current output to power the motor.
This servo drive operates in torque, velocity, or position mode. It can control brushed or brushless motors and features space vector modulation for high efficiency. The drive has configurable digital and analog inputs/outputs, supports various feedback and command sources, and complies with relevant safety standards. It provides 100A peak current output from a 240VAC supply.
The document describes a DigiFlex® PerformanceTM Servo Drive model DPRAHIR-060A800. It can provide up to 60A of peak current and 30A of continuous current from a 200-480VAC power supply. It is designed to drive brushed and brushless servomotors in torque, velocity, or position mode using space vector modulation. It has configurable digital and analog inputs and outputs for interfacing with external devices.
This document provides specifications for the DigiFlex® PerformanceTM Servo Drive DPCANIA-030A800. It is a digital servo drive designed to drive brushed and brushless servomotors in torque, velocity, or position mode. It features a CANopen interface for networking and RS-232 interface for configuration. It has a peak current of 30A and continuous current of 15A, with a supply voltage range of 200-480VAC.
This document provides information on the DigiFlex® PerformanceTM Servo Drive DPCANIA-060A800. It can drive brushed and brushless servomotors in torque, velocity, or position mode using space vector modulation. It features a CANopen interface, configurable I/O, and supports various feedback devices. The drive is compliant with relevant safety standards and has protection against overcurrent, overtemperature, and other fault conditions.
This document provides specifications for the DigiFlex® PerformanceTM Servo Drive DPRANIR-015A400. It is a digital servo drive that can operate in torque, velocity, or position mode. It has inputs and outputs for interfacing with external devices and can be configured through a RS-232/RS-485 interface using DriveWare® 7 software. Key features include regenerative braking, space vector modulation, and configurable gains, limits, and I/O.
This document provides information on the DigiFlex® PerformanceTM Servo Drive DPRANIR-060A800. It can drive brushed and brushless servomotors in torque, velocity, or position mode. Key features include space vector modulation, configurable I/O, and compliance with CE and RoHS standards. The drive has a peak current of 60A, continuous current of 30A, and accepts a 200-480VAC supply voltage.
This document provides information on the DigiFlex® PerformanceTM Servo Drive DPRANIR-015S400. It can drive brushed and brushless servomotors in torque, velocity, or position mode using space vector modulation. It has a peak current of 15A, continuous current of 7.5A, and operates from a 100-240VAC supply. The drive has configurable digital and analog inputs/outputs and supports various feedback devices and command sources for motor control applications.
This document provides information on the DigiFlex® PerformanceTM Servo Drive DPRAHIR-015A400. It can drive brushed and brushless servomotors in torque, velocity, or position mode. Key features include regenerative braking, space vector modulation for efficiency, and configurable inputs/outputs. It has a peak current of 15A, continuous current of 7.5A, and supports feedback from encoders and resolvers.
The DigiFlex® PerformanceTM Servo Drive DPRAHIR-030A400 is a digital servo drive designed to drive brushed and brushless servomotors in torque, velocity, or position mode. It features 30A peak current, 15A continuous current, and operates in a voltage range of 100-240VAC. The drive is configured and commissioned using DriveWare® 7 software and includes inputs, outputs, and feedback support for connecting to motors and external devices.
This document provides specifications for the DigiFlex® PerformanceTM Servo Drive DPRAHIR-060A400. It can drive brushed and brushless servomotors in torque, velocity, or position mode using space vector modulation. It features programmable digital and analog inputs/outputs, configurable command sources, and supports various feedback types including encoders. The drive is compliant with various safety standards and has a peak current rating of 60A, continuous current of 30A, and operates from a 100-240VAC supply.
The DigiFlex Performance Servo Drive DPRAHIS-030A400 is a digital servo drive designed to drive brushed and brushless servomotors in torque, velocity, or position mode. It features a peak current of 30A, continuous current of 15A, and operates on a supply voltage of 100-240VAC. The drive uses space vector modulation for motor control and features programmable digital and analog inputs/outputs to interface with external devices.
This servo drive operates in torque, velocity, or position mode. It features a CANopen interface for networking and RS-232 interface for setup. It can control brushed or brushless motors in various operation modes like profile position or velocity. It has programmable digital and analog inputs/outputs and supports feedback from encoders or Hall sensors. Agency approvals include UL, cUL, and CE compliance.
This document provides information on the DigiFlex® PerformanceTM Servo Drive DPRAHIR-015S400. It is a fully digital servo drive designed to drive brushed and brushless servomotors in torque, velocity, or position mode. It features space vector modulation, configurable I/O, and is configurable and commissionable via DriveWare® software over an RS-232/485 interface. The drive provides 15A peak and 7.5A continuous current output from a 100-240VAC input and is compliant with various safety standards.
The DigiFlex® PerformanceTM Servo Drive DPCANIA-015A400 is a digital servo drive that can operate in torque, velocity, or position mode. It has a peak current of 15A, continuous current of 7.5A, and accepts a supply voltage of 100-240VAC. The drive features Space Vector Modulation, configurable I/O, and CANopen and RS-232 interfaces for communication and setup.
The DigiFlex® PerformanceTM Servo Drive DPCANIE-060A800 is a digital servo drive designed to drive brushed and brushless servomotors in torque, velocity, or position mode. It features a CANopen interface for networking and RS-232 interface for configuration. The drive supports various command sources, feedback types, and has programmable digital and analog inputs and outputs to interface with external devices. It is compliant with European CE standards and RoHS requirements.
The DigiFlex® PerformanceTM Servo Drive DPRAHIR-030A800 is a digital servo drive designed to drive brushed and brushless servomotors in torque, velocity, or position mode. It employs Space Vector Modulation technology for high efficiency and features configurable inputs/outputs, communication interfaces, and approval for CE and RoHS compliance. The drive provides 30A peak current output from a 200-480VAC, 3-phase power supply.
This document provides specifications for the DigiFlex® PerformanceTM Servo Drive DPCANIR-030A800. It can supply up to 30A peak current and is designed to drive brushed and brushless servomotors in torque, velocity, or position mode. It features Space Vector Modulation, PID control loops, configurable I/O, and complies with various safety standards including CE and RoHS.
Automatic Weather Station with Sun Tracker Energy Centerwebadminjk
Sutron Corporation delivered an AWS with Sun Tracker in order to help the Energy Center at KNUST observe and analyze the sun’s radiation, i.e., global solar radiation (pyranometer), diffused solar radiation (pyranometer with shadding assembly), direct normal irradiance or DNI (pyrheliometer), and
sunshine duration.
Data loggers (DCP) are specialized field computing devices that allow for sensors and telemetry devices to be connected to them, allowing for remote data collection and retrieval by the user.
LinkComm Quick Start Guide for Mobile Deviceswebadminjk
LinkComm is a program used to view status and configure Sutron data loggers. LinkComm runs on PC and Macs, but also on Apple iPhones and iPads, and Android phones and tablets.
The new 8310 exceeds Sutron’s 8210 logger’s capabilities while maintaining the same popular interface 8210 users will recognize. Using low-power circuitry, it achieves long-life battery operation and provides a rugged system for unattended field applications in extreme environments.
AT/RH Radiation Shield - Protects Temperature and relative humidity sensors from error-producing solar radiation and precipitation, Compact size and light weight make this shield useful for many applications
The Digital SDI Soil Moisture Sensor represents
a revolutionary advance in the irrigation industry
and is now available as a research tool. The digital
sensor is a very effective tool to log moisture data
for a variety of applications
Aqua temp submersible temperature sensorwebadminjk
The AquaTemp® is a rugged, submersible digital precision temperature sensor. The sensor is compatible with the industry standard, SDI-12 protocol v1.3. The sensor consists of a precision calibrated digital sensor accurate to ±0.1°C (-5°C to +45°C). The sensor can be ordered with variable lengths of UV resistant cable.
Air Temperature Sensor 5600-0025 - Highly Accurate, High Sensitivity, low Power - Encased in a stainless steel sheath for protection from handling and the element.
The Compact Constant Flow Bubbler (Part #56-0133-25-1ST), 50% smaller than Sutron’s original Constant Flow Bubbler, is a self-contained, precision device to measure water levels & temperature.
Sutron win customezed web hosting & data visualizationwebadminjk
SutronWIN, our advanced web service for hydro-meteorological data collection, handles the complexity of retrieving data from many different types of interfaces. Then, SutronWIN delivers collected data to you via the web in the format of your choice, ready to use.
The Aquatrak Sensor calculates the true average level even in the presence of waves and surging liquid surfaces. The Sensor can be configured via its communication ports for virtually any site-unique conditions.
Low power design makes it ideally suited for remote
monitoring applications.
Includes 2 or 3 transducers for redundancy.
Capable of operating at elevations of 2300 feet below sea level to 18,300 feet above sea level.
Wide temperature range -40°C to +60°C.
Accubar Burbujeador (Medidor de la Burbuja) 5600-0131webadminjk
El medidor de Burbuja Accubar es un sensor autónomo, completamente libre de mercurio y nitrógeno diseñado para el agua medir nivel de agua y bajo en mantenimiento.
Designed for a multitude of applications from coasts to rivers, the Profiler is a small, lightweight & cost-effective solution for shallow water (<100 m). Deploy it on the bottom, on a buoy or on a mooring line. Aquadopp is complete including all parts required for a self-contained deployment with internal batteries & a datalogger. Additional configurations are available.
This document provides information about a first class pyranometer made by Sutron Corporation. It lists common applications of pyranometers such as crop management, global radiation measurement, and irrigation control. It also provides helpful installation tips, noting pyranometers should be mounted facing south in the northern hemisphere and north in the southern hemisphere. An overview then describes the specific pyranometer model in more detail as compliant with ISO standards and suitable for measuring solar irradiance on a plane surface. Finally, the specifications of the pyranometer are listed, including its spectral range, sensitivity, response time, accuracy, dimensions and weight.
Acoustic doppler current profiler (adcp)webadminjk
The most accurate and reliable Real-Time Monitoring Systems in the world base their Data Collection Platforms on Sutron’s Xpert Datalogger Series. With custom RDI drivers, they’re designed precisely to handle any Real-Time
ADCP Application. And, they’re manufactured in the USA
to strict ISO 9001
standards.
A precision three-axis wind measurement anemometer,
the WindMaster monitors wind speeds of 0-45m/s and
provides sonic temperature, speed of sound and U, V & W
vector outputs at 20Hz (32Hz optional).
A Comprehensive Guide on Cable Location Services Detections Method, Tools, an...Aussie Hydro-Vac Services
Explore Aussie Hydrovac's comprehensive cable location services, employing advanced tools like ground-penetrating radar and robotic CCTV crawlers for precise detection. Also offering aerial surveying solutions. Contact for reliable service in Australia.
GFW Office Hours: How to Use Planet Imagery on Global Forest Watch_June 11, 2024Global Forest Watch
Earlier this year, we hosted a webinar on Deforestation Exposed: Using High Resolution Satellite Imagery to Investigate Forest Clearing.
If you missed this webinar or have any questions about Norway’s International Climate & Forests Initiative (NICFI) Satellite Data Program and Planet’s high-resolution mosaics, please join our expert-led office hours for an overview of how to use Planet’s satellite imagery on GFW, including how to access and analyze the data.
The modification of an existing product or the formulation of a new product to fill a newly identified market niche or customer need are both examples of product development. This study generally developed and conducted the formulation of aramang baked products enriched with malunggay conducted by the researchers. Specifically, it answered the acceptability level in terms of taste, texture, flavor, odor, and color also the overall acceptability of enriched aramang baked products. The study used the frequency distribution for evaluators to determine the acceptability of enriched aramang baked products enriched with malunggay. As per sensory evaluation conducted by the researchers, it was proven that aramang baked products enriched with malunggay was acceptable in terms of Odor, Taste, Flavor, Color, and Texture. Based on the results of sensory evaluation of enriched aramang baked products proven that three (3) treatments were all highly acceptable in terms of variable Odor, Taste, Flavor, Color and Textures conducted by the researchers.
1. Sutron Corporation | 22400 Davis Drive | Sterling, VA 20164 | 703.406.2800 | www.sutron.com | sales@sutron.com
3/7/2014
Stage Discharge Recorder
(SDR)
Overview
Sutron fused our ultra-reliable SDI-12 optical encoder with our state-of-the-art
SatLink2 Logger technology to create an encoder that never forgets.
Features
Dual Sensor: Setup SDR to measure a second stage using an analog* or
SDI-12 sensor
Rating Table: Compute discharge using a rating table with up to 50 points
Averaging: Stage can be computed by averaging multiple samples over a
user-set period
4-20mA output:* Output stage or discharge using the 4-20mA circuit
(*requires SDR w/analog: SDR-0001-4 )
With proven float-tape-counterweight technology, it’s a “plug compatible”
replacement for a Stevens strip chart or punched-tape recorder.
Saves your data in ultra-reliable Flash Memory
No back-up batteries and you never lose your data
Incorporates standard flume and weir equations
Computes and logs discharge totals
Displays discharge as well as flume/weir stage
Built-in event log tracks events such as data views, data downloads, and
setup changes
Runs up to 1 year on an industrial alkaline battery
Data delivered in easy-to-read & -open CSV files
All setup can be done from front panel
Download utilities available for Pocket PC-compatible PDAs & Windows
laptops
SD Card Option
Sutron Recommends
1. Stilling well with minimum 8” diameter
2. 5/16” shaft float wheel/pulley with circumference of 12”, 18”, & 375mm. If
the float wheel does not have an insulating hub, a PVC float must be used.
(See Ordering Options)
3. Beaded wire/tape compatible with the float wheel.
4. Float/counterweights.
5. 12-volt alkaline battery with capacity of at least 20 amp-hrs. (See Ordering
Accessories).
Stage Discharge Recorder
Model SDR-0001-1
Displays
Stage - Daily & Log
Volume So Far Today
Flow
Discharge
Review Discharge by Day
Applications & Benefits
SDR is a Logging Shaft Encoder used in
surface water & groundwater applications.
Front panel programmable, it holds over one
year of data, & operates for over one year on
alkaline batteries.
An SDR model is available with an SD Card
Slot for log retrieval.
SDR works with low-cost cellular data
modems & Sutron’s Autopoll Desktop
Software to create an automatically-polled,
IP-based data collection system.
SDRs are also SDI-12 sensors.
SDR works for sites with or without stilling
wells
Ground Water Monitoring
Records Discharge on Canals, Ditches,
Turnouts, etc.
Runs all year on 2 lantern batteries
Log file does not erase.
Simply enter flume/weir formula
2 years of data storage
2. Sutron Corporation Stage Discharge Recorder 2
Sutron Corporation | 22400 Davis Drive | Sterling, VA 20164 | 703.406.2800 | www.sutron.com | sales@sutron.com
3/7/2014
Stage Discharge Recorder Analog Model
(SDR Analog) SDR-0001-3
Applications
0-5 V Sensors
Low-Level Bridge Output Sensors
4 to 20 mA Sensors
SDR analog sensor input version works with ultrasonics, submersibles
& other sensors.
A switched 24-volt power supply provides everything needed to
operate 4 to 20mA loop sensors.
Features
Extremely Accurate, Low-Noise Analog Measurement System
Removable terminal strip(s)
0-5 V Single Ended Analog Input
0 to (+/-)39 mV Differential Analog Input (for Bridge Type Pressure
Sensors)
4-20 mA Input
2.5 V Precision Reference Voltage
Switched Battery Output to power sensors and conserve battery
power when not performing measurements
24 V Output to power 4-20 mA current loop sensors
SDR ANALOG SPECIFICATIONS
Specifications subject to change without notice
Operating Voltage 8-16 Volts
Operating Temperature Range -40° C to +60° C
Volt Reference 2.5 volt reference, +/- 10 mv, 19 mA max
Reference Temperature
Coefficient
10 ppm/° C max
A/D Number of Bits 24
Switched Battery Short Protected
SINGLE ENDED INPUTS 2 CHANNELS*
Full Scale 0 to 5 Volts
Resolution 0.298 uV
Noise (p/p) @25° C 6.5 uV (p/p)
Noise (rms) @25 ° C 3.4 uV RMS
Accuracy @25° C 0.02% FS
Input Impedance >2M Ohm
DIFFERENTIAL INPUTS 3 CHANNELS*
Full Scale +/- 0.0390625 V
Resolution 4.657 nV
Noise (p/p) @25° C 1.6 uV (p/p)
Noise (rms) @25° C 0.38 uV
Accuracy @25° C <.01% ratiometric
Input Impedance >3M Ohm
4-20mA INPUT 1 CHANNEL*
Full Scale 20mA
Resolution <1mA
Accuracy @25° C .02% FS
24 Volt Current Loop Pwr 24 Volt +/- 5%, short protected
NOTE: Software supports only 2 total
measurements: Stage & Additional Sensor.
Other channels are for future use.
3. Sutron Corporation Stage Discharge Recorder 3
Sutron Corporation | 22400 Davis Drive | Sterling, VA 20164 | 703.406.2800 | www.sutron.com | sales@sutron.com
3/7/2014
SPECIFICATIONS
Specifications subject to change without notice
Measurements Stage/Level measurements, Internal Temp, Battery.
Note: a second stage can be measured via SDI-12 or
via optional analog interface.
Automeasure
Interval
15-minute default, 1, 5, & 10 minutes user selectable. 30
& 60 minute intervals also available.
Stage/Level
Resolution
Shaft encoder has 400 count/revolution. SDR-0001-
3 supports analog input in place of the encoder. The
analog input can measure a 0-5V sensor, 4-20ma
sensor or resistive bridge sensor.
Shaft 5/16” diameter
Supported Wheels 1ft, 00.375 meter, 0.5 meter and custom
Stage/Level Range +/-80 ft of calibration point
Calculations Discharge using Parshall Flume, Broad Crested Weir
equations, Dual Sensor, Rating Table or general
purpose equation with user entered constants.
Calculation of daily volume and daily average stage.
Recording intervals 15-minute default, 1, 5, & 10 minutes user selectable.
30 & 60 minute intervals also available.
Available data Station name, date/time, current stage, current
discharge, current total, battery voltage & logged
values of the stage & discharge, daily average stage,
average discharge & total discharge.
Enclosure NEMA 3, IP63 resists dripping water & spray
Comm. Ports SDI-12, RS232
Operating Temp -40°C to +60°C
Display Type 2x20 LCD with backlight
Keypad Type 6 button
Memory
Built-In Flash >300,000 readings
SD yes
USB no
Ethernet no
Clock Accuracy (at
0°C – 40°C)
2 minutes per month, optional RS232 GPS sync
Power
Requirements
5.5 to 16 VDC
Current Drain <3.5mA @12 VDC
Communication
Protocols
MODBUS Slave. SCP, SDI-12
Programming via front panel or SDR communicator program
Log capacity Over one (1) year of 15-minute stage data with
accompanying daily average of discharge and
midnight battery voltage
Log wrapping PERMANENT LOG wraps when full (oldest data
replaced by newest data). There is NO mechanism to
erase the log.
Data downloads Compatible with Pocket PC , PDA or laptop/desktop
Windows PC
Event log Any stage or setup changes written to the event log.
Download time Less than 6 minutes, even for a 6-month log
Download Comma-separated variable (CSV)
Graphing data PDA and laptop utilities provide data graphing
Status lights 2 on front panel show “heartbeat” & run/error status
Device Dimensions
Height 4.5” (11.5 cm)
Length 4” (10.2 cm)
Width 7” (17.8 cm)
ORDERING
SDR-0001-1 Stage Discharge Recorder,
Standard Unit, with shaft
encoder only. Battery cable
included.
SDR-0001-1SD SDR-0001-1 with SD Card
SDR-0001-3 SDR w/Analog Input &
4-20mA outputs
The Analog Stage
Discharge Recorder does
not include a shaft encoder.
Order separately.
SDR-0001-3SD SDR-0001-3 with SD Card
SDR-0001-4 SDR w/Analog Input,
4-20mA outputs,. Includes
a shaft encoder
SDR-0001-4SD SDR-0001-4 with SD Card
ACCESSORIES
5100-0040 Battery, 12VDC, 24 AH,
sealed, rechargeable
lead-acid
5100-0530-2 Float, 6” PVC
5100-0118-1 Float Wheel, 375mm/revo-
lution for beaded cable and
5/16” shaft
5100-0581 Chain, Beaded, 12.5cm, 1
Meter Length Increments
5100-0550 Counterweight, 8 oz.
6661-1213 2 GB SD Card
SHIPPING
Shipping Height 14 in. (35.6 cm)
Shipping Length 10 in. (25.4 cm)
Shipping Width 6 in. (15.3 cm)
Shipping Weight 5 lbs. (2.3 Kg)
Batteries not Included: Use lead acid or
alkaline batteries providing 12 volts or use two
6 volt lantern batteries (Eveready 528 or 529)
connected in series. In most applications this will
provide 12 months of operation.