This document lists cables and accessories approved for connection to SP Distribution, SP Manweb and SP Transmission networks. It covers cables, joints, terminations, ducts and other accessories. The document provides references to relevant standards and specifications. Equipment is assigned approval categories of A (fully approved) or S (approved for specific contracts). Only approved equipment listed in the appendices may be installed on the networks. Cables and accessories must meet technical specifications on insulation, sheathing and testing. Ducts must comply with ducting specifications. Joints and terminations must meet jointing specifications. The document is reviewed every 5 years or when new equipment is approved.
This document provides an overview and summary of SpryWare's standard operating procedures. It outlines the company's locations, contact information, service level agreements, processes and procedures. It also describes the hosted data centers, available toolsets, communication and training practices, and the Direct Market Server solution. The document references additional standalone documents that provide more detailed information on specific topics like Active Directory, backups, and new employee onboarding.
This document specifies the EAX protocol used between Amdocs billing systems and eServGlobal IN service applications. The protocol uses TCP/IP sockets to connect an eServGlobal service control point to multiple Amdocs billing servers. Message types defined include subscriber queries, charging requests, and subscriber updates. The document covers connection handling, message structure, parameters for each message type, and failure recovery procedures.
- Configuration is stored as LDAP entries under cn=config within the directory
- Server plug-ins have their own configuration entries under cn=plugins,cn=config
- Configuration data is output to LDIF files located in /var/lib/dirsrv/instance/ldif
- Schema configuration files are located in /etc/dirsrv/instance/schema
- Core configuration attributes are referenced in an alphabetical listing
This document provides requirements for developing graphical user interfaces (GUIs) using the Qt framework and EPICS channel access (CA) at the Australian Synchrotron. It specifies that GUIs shall interface with EPICS and be built within the Australian Synchrotron's formal build system. It also provides requirements for integrated development environments, operators, and common Qt widgets that interface with EPICS CA. The goal is to establish standards for cross-platform GUI development across the accelerator and beamlines using Qt/C++.
This document provides guidance on installing and updating SAP HANA systems. It discusses SAP HANA system concepts, hardware and software requirements, and the installation process. The installation can be done interactively or automated using parameters and configuration files. Updates can be applied locally or remotely to the SAP HANA system and its individual components. The document also includes a reference for installation and update parameters.
GenieEvo is an indoor medium voltage switchgear assembly for electrical distribution from 3.3kV to 13.8kV. It provides maximum user safety with high-performance vacuum circuit breakers, digital protection and control systems, and arc-resistant cubicles. GenieEvo has proven reliability and is suitable for network operators, infrastructure, data centers, and commercial sites.
High Voltage Cable Terminations (SWA) with CMP Zen Insulated Cable Glands & Cast Integral Earth Lug
CMP Zen Glands - Protect Against Short Circuit Earth Fault Currents
CMP Zen A324 Insulated Aluminium Cable Glands with Cast Integral Earth Lug (Supply)
CMP A324 Zen insulated aluminium cable glands are suitable for the cable termination of all low voltage and high voltage aluminium wire armoured (AWA) cables, indoor and outdoor with IP66 seal - CMP A324 Zen insulated aluminium cable glands feature CMP Cast Integral Earth Lug (CIEL) allowing the zoning of earth connections for earthed neutral systems.
CMP Zen Insulated Cable Glands - High Voltage Cable Termination with Brass or Aluminium Cable Glands
In the power generation industry unless special measures are taken to both segregate LV-HV cables in accordance with wiring regulations, and also isolate the metallic cable armour from running in continuous contact throughout the whole of the earthing system, interference or electrical noise would spread throughout the plant. CMP Zen Insulated cable gland system allows cables to be earthed at one end only - single point earthing - and insulated at the field end. Insulated Zen cable glands are available to ensure that no contact is made between the earth circuit carried through the cable armour and the low-high voltage electrical enclosure which the cable enters. CMP Zen Insulated cable glands permit electrical design engineers to implement safe earthing systems to deal with :
*Cross Talk Noise Reduction
*Electrical Separation of Main Earths
*Earth Fault Segregation
*Fault Current Reduction with Series Cable Resistance
*Electrical Noise Reduction in Instrument Cables
*Circulating Current Production in Single or 3 Core High Voltage Cables
CMP Zen Insulated Cable Glands - CMP A324 & A348
CMP Zen Insulated cable glands are suitable for use with all aluminium wire armoured (AWA) cables providing an IP66 environmental seal on the cable outer sheath. CMP A324 Zen glands feature Cast Integral Earth Lug (CIEL) suitable for high voltage power cable systems where a high level of protection against fault currents is required - CMP's unique cable glanding concept effectively insulates the gland and cable armour from the electrical equipment eliminating circulating currents. CMP Zen A324 cable gland is usually installed at the supply end of the cable and Zen A348 cable gland at the load end - suitable for 3.3kV, 6.6kV, 11kV and 33kV single core AWA high voltage power cable glanding.
This document provides information about low profile transition boots for insulating and protecting cable harness breakouts. It lists various boot models and their specifications, including sizing details. Adhesive options are indicated. The boots are supplied in an expanded form for installation and then recover fully after heating.
This document provides an overview and summary of SpryWare's standard operating procedures. It outlines the company's locations, contact information, service level agreements, processes and procedures. It also describes the hosted data centers, available toolsets, communication and training practices, and the Direct Market Server solution. The document references additional standalone documents that provide more detailed information on specific topics like Active Directory, backups, and new employee onboarding.
This document specifies the EAX protocol used between Amdocs billing systems and eServGlobal IN service applications. The protocol uses TCP/IP sockets to connect an eServGlobal service control point to multiple Amdocs billing servers. Message types defined include subscriber queries, charging requests, and subscriber updates. The document covers connection handling, message structure, parameters for each message type, and failure recovery procedures.
- Configuration is stored as LDAP entries under cn=config within the directory
- Server plug-ins have their own configuration entries under cn=plugins,cn=config
- Configuration data is output to LDIF files located in /var/lib/dirsrv/instance/ldif
- Schema configuration files are located in /etc/dirsrv/instance/schema
- Core configuration attributes are referenced in an alphabetical listing
This document provides requirements for developing graphical user interfaces (GUIs) using the Qt framework and EPICS channel access (CA) at the Australian Synchrotron. It specifies that GUIs shall interface with EPICS and be built within the Australian Synchrotron's formal build system. It also provides requirements for integrated development environments, operators, and common Qt widgets that interface with EPICS CA. The goal is to establish standards for cross-platform GUI development across the accelerator and beamlines using Qt/C++.
This document provides guidance on installing and updating SAP HANA systems. It discusses SAP HANA system concepts, hardware and software requirements, and the installation process. The installation can be done interactively or automated using parameters and configuration files. Updates can be applied locally or remotely to the SAP HANA system and its individual components. The document also includes a reference for installation and update parameters.
GenieEvo is an indoor medium voltage switchgear assembly for electrical distribution from 3.3kV to 13.8kV. It provides maximum user safety with high-performance vacuum circuit breakers, digital protection and control systems, and arc-resistant cubicles. GenieEvo has proven reliability and is suitable for network operators, infrastructure, data centers, and commercial sites.
High Voltage Cable Terminations (SWA) with CMP Zen Insulated Cable Glands & Cast Integral Earth Lug
CMP Zen Glands - Protect Against Short Circuit Earth Fault Currents
CMP Zen A324 Insulated Aluminium Cable Glands with Cast Integral Earth Lug (Supply)
CMP A324 Zen insulated aluminium cable glands are suitable for the cable termination of all low voltage and high voltage aluminium wire armoured (AWA) cables, indoor and outdoor with IP66 seal - CMP A324 Zen insulated aluminium cable glands feature CMP Cast Integral Earth Lug (CIEL) allowing the zoning of earth connections for earthed neutral systems.
CMP Zen Insulated Cable Glands - High Voltage Cable Termination with Brass or Aluminium Cable Glands
In the power generation industry unless special measures are taken to both segregate LV-HV cables in accordance with wiring regulations, and also isolate the metallic cable armour from running in continuous contact throughout the whole of the earthing system, interference or electrical noise would spread throughout the plant. CMP Zen Insulated cable gland system allows cables to be earthed at one end only - single point earthing - and insulated at the field end. Insulated Zen cable glands are available to ensure that no contact is made between the earth circuit carried through the cable armour and the low-high voltage electrical enclosure which the cable enters. CMP Zen Insulated cable glands permit electrical design engineers to implement safe earthing systems to deal with :
*Cross Talk Noise Reduction
*Electrical Separation of Main Earths
*Earth Fault Segregation
*Fault Current Reduction with Series Cable Resistance
*Electrical Noise Reduction in Instrument Cables
*Circulating Current Production in Single or 3 Core High Voltage Cables
CMP Zen Insulated Cable Glands - CMP A324 & A348
CMP Zen Insulated cable glands are suitable for use with all aluminium wire armoured (AWA) cables providing an IP66 environmental seal on the cable outer sheath. CMP A324 Zen glands feature Cast Integral Earth Lug (CIEL) suitable for high voltage power cable systems where a high level of protection against fault currents is required - CMP's unique cable glanding concept effectively insulates the gland and cable armour from the electrical equipment eliminating circulating currents. CMP Zen A324 cable gland is usually installed at the supply end of the cable and Zen A348 cable gland at the load end - suitable for 3.3kV, 6.6kV, 11kV and 33kV single core AWA high voltage power cable glanding.
This document provides information about low profile transition boots for insulating and protecting cable harness breakouts. It lists various boot models and their specifications, including sizing details. Adhesive options are indicated. The boots are supplied in an expanded form for installation and then recover fully after heating.
O documento descreve o sistema de barramentos Duresca® para uso interno e externo. O sistema possui isolamento feito de papel envolto e resina epoxi aplicada ao condutor de alumínio ou cobre. As barras são produzidas em seções de até 10 metros e conectadas no local com articulações flexíveis ou rígidas. O documento também descreve as conexões do sistema para transformadores e sistemas isolados a gás.
This document provides specifications for triplex cable surrounds and details for selecting cable cleats to be used with the surrounds. It lists the minimum and maximum diameters for various triplex cable surround models. It also provides a table with information about specific surrounds and compatible cleat sizes. The document confirms the products have been tested according to EN 50368 and lists the maximum short circuit test level.
This document provides information to help identify types of underground power cables and equipment that have been stolen from ScottishPower's electricity network. It includes descriptions and images of low voltage plastic and paper insulated cables, 11kV and 33kV plastic and paper insulated cables, identification tapes and tiles placed over buried cables, and some associated substation equipment. The document is intended as an aid for deterring metal theft and identifying stolen cables and equipment.
This document discusses problems caused by cold temperatures such as delays in projects and maintenance due to issues with painting, coating, and repairs curing. It then introduces the SA FlexiHeat ATEX heater as a solution. The heater is compact, powerful, and portable, allowing it to be used in different locations and configurations. It is ATEX certified for safety in hazardous environments and has an efficient heating element design. The heater can help problems like insufficient temperatures for painting, composite repairs not curing properly, and condensation or freezing of machinery.
This document provides specifications for Nexans 6350/11000 Volt XLPE cables with stranded copper conductors and copper wire screens for UK Power Networks. The cables come in nominal cross-sectional areas from 300 to 800 mm2. Key specifications include approximate diameter, thickness of insulation and sheath, number of copper wire screens, capacitance, resistance, inductance, and short circuit ratings.
Vulcan + cable cleats are designed for trefoil, single, quad and bundled cable applications where moderate short circuit withstand is required. They have a compact, patented design that allows for easy installation in spaces with limited space. The cleats are made of stainless steel to withstand harsh environments and include a polymeric liner and removable base pad to protect cables during short circuits. They have passed testing for impact resistance, resistance to electro-mechanical forces, and can withstand temperatures from -40 to 60 degrees Celsius.
The Roxtec BGTM product family is designed to safely and efficiently bond or ground armored and shielded cables through a single cut-out or open- ing in a wall, floor or electrical enclosure. The product provides a secure means of cable terminations and pass-throughs, provides an environmental and fire resistant seal, and establishes a secure bonding path to ground for metallic cable components. The product is certified for use in hazardous locations where required by local codes and regulations. The Roxtec BGTM system complies with EU directive 2002/95/EC, Restriction of Hazardous Substances (RoHS).
This document is an electrical product catalogue from Ellis that includes information about various cable cleat products. It summarizes that Ellis cable cleats are tested to high standards to guarantee they will contain short-circuit forces and protect infrastructure. The catalogue then provides details on specific cleat product lines including Alpha, Emperor and Vulcan+ cleats. It describes the materials, maximum short-circuit test levels, recommended spacing and fixing for each product. Dimensions, weights and part numbers are shown in selection tables.
The document provides information on cable cleats, including:
- What cable cleats are and why they are necessary to restrain cables and prevent movement from fault currents.
- International standards that specify cable cleats must withstand electromagnetic forces from faults and be rated for cable size and current.
- Short-circuit testing is outlined as the best way to test cable cleats' ability to withstand fault conditions, and the IEC standard's methodology is described.
- A formula from the IEC standard is presented to calculate cable cleat spacing based on fault level and cable size.
This document provides information about G&W Electric's cable accessories, including:
1. G&W Electric manufactures cable accessories such as terminations and joints rated from 69kV to 230kV for extruded dielectric cable systems.
2. The accessories are factory molded and tested, and installation options include mechanical shrink or slip on methods.
3. G&W Electric has certification for its products and testing facilities to ensure product quality and reliability.
Roxtec Cable Transits - Installing & Terminating Substation Cables
Roxtec cable transits provide several clear advantages for installing and terminating cables in industrial and high voltage substations. Roxtec cable transits provide a standardised design with the flexibility to terminate a variety of different sizes and cable constructions. The ease of cable installation reduces labour costs and minimises the potential for cable insulation damage. The structural and environmental integrity of the wall or floor penetration is maintained providing an insulated, vapor-tight and fire-stop barrier and cables can be easily added for future up-grading. Roxtec cable transits are a viable alternative for terminating cables into industrial power substations.
The document is a catalogue from Nexans that describes their Euromold division and the products they offer. Euromold specializes in prefabricated cable accessories for medium voltage energy distribution, including connectors, joints, bushings and terminations from 12-42kV. The catalogue provides information on their separable connectors, including tee connectors in different voltage classes and sizes to connect cables to equipment or other cables. It describes the components, standards, and provides ordering information.
Cembre B135C Hydraulic Crimping Tool - Battery Crimping Tools
14.4V cordless hydraulic battery crimping tool
Lightweight and balanced Cembre crimper for single hand operation
Double speed crimping action
Cembre crimping head can rotate through 180°
Quiet in operation with very little vibration
Operating buttons mechanically interlocked to prevent accidental operation
Microprocessor control with automatic motor cut out on completion of the crimping operation
Fitted with a maximum hydraulic pressure valve
Cembre B135C Battery Crimpers - Crimping Applications
HV & LV cable lugs - 400sqmm
HV & LV cable splices - 240sqmm
Insulated cable terminals - 240sqmm
C Sleeve connectors - 185sqmm
The document is a 2014 catalogue from Nexans Network Solutions Division Euromold. It provides information on Euromold's medium voltage cable accessories, including:
- Euromold is a leading European manufacturer and distributor of prefabricated cable accessories for medium voltage energy distribution, providing a complete range of accessories for underground cables.
- The catalogue describes Euromold's ISO 9001 certification and independent laboratory accreditation, and notes that all products meet international standards.
- It provides specifications, diagrams and ordering information for various separable connectors and equipment bushings, including elbow connectors, tee connectors, and equipment bushings for interfaces up to 36kV and 400A.
This document is a catalogue from Nexans Network Solutions Div. Euromold that provides information on cable accessories. It describes various prefabricated cable accessories that Euromold manufactures for medium voltage energy distribution, including premoulded EPDM rubber connectors for cables and epoxy bushings. It provides details on Euromold's ISO 9001 and laboratory accreditation certification. The document also includes specifications for separable connectors like the 158LR elbow connector and 152SR straight connector that are designed to connect cables to equipment up to 24kV and 250A. It provides ordering information and diagrams for these connectors.
This document provides information on Euromold's medium voltage symmetrical separable connectors, including the Interface C connectors. It describes the 400LB elbow connector, 400TB and 440TB tee connectors, their design, specifications, standards, kit contents and ordering instructions. Euromold is a leading European manufacturer and distributor of prefabricated cable accessories for medium voltage energy distribution.
This document provides installation instructions for heatshrink joints for fire resistant XLPE/SWA/LSOH or EPR/GSB cables with 3 to 5 cores and voltages of 0.6/1kV. The instructions specify preparing the cable ends according to dimensions in a table. Conductors are exposed and connected, then insulation tubes are positioned and shrunk. Fire barrier tape and an inner shrink tube are applied over the connections. Copper mesh and an outer shrink tube are wrapped around the joint and secured. A fire barrier tube is slid over and fastened with roll springs.
Ellis Patents Alpha cable cleats are available for trefoil and single cable applications where moderate levels of short circuit withstand are required. Ellis Patents Alpha cable cleats unique design allows rapid installation offering significant man hours and labour saving for cable contractors.
Ellis Patents Alpha cable cleats are compliant with London Underground Engineering Standard 1-085 - Product Register No.360.
Alpha cable cleats are manufactured from extruded aluminium (6000 series) to BS EN 755, the cleat is lighter and tougher than the cast aluminium cable cleat product it is designed to replace - cleats are supplied with zinc plated closing fasteners.
The document provides an overview of the LS 4000i Series scanners:
- It describes the different scanner models in the LS 4000i Series (LS 4004i, LS 4005i, LS 4006i, LS 4007i) and how to set them up for scanning barcodes.
- It discusses connecting the scanners to a host system for 1-D or 2-D barcode scanning and transmitting scan data.
- It includes specifications for the scanners as well as maintenance instructions and parameter settings.
The APP pumps provide unsurpassed efficiency and great flexibility for configuration. The simple construction of the axial piston pump with fewer parts allows highly reliable operation with long service intervals and easy maintenance.
O documento descreve o sistema de barramentos Duresca® para uso interno e externo. O sistema possui isolamento feito de papel envolto e resina epoxi aplicada ao condutor de alumínio ou cobre. As barras são produzidas em seções de até 10 metros e conectadas no local com articulações flexíveis ou rígidas. O documento também descreve as conexões do sistema para transformadores e sistemas isolados a gás.
This document provides specifications for triplex cable surrounds and details for selecting cable cleats to be used with the surrounds. It lists the minimum and maximum diameters for various triplex cable surround models. It also provides a table with information about specific surrounds and compatible cleat sizes. The document confirms the products have been tested according to EN 50368 and lists the maximum short circuit test level.
This document provides information to help identify types of underground power cables and equipment that have been stolen from ScottishPower's electricity network. It includes descriptions and images of low voltage plastic and paper insulated cables, 11kV and 33kV plastic and paper insulated cables, identification tapes and tiles placed over buried cables, and some associated substation equipment. The document is intended as an aid for deterring metal theft and identifying stolen cables and equipment.
This document discusses problems caused by cold temperatures such as delays in projects and maintenance due to issues with painting, coating, and repairs curing. It then introduces the SA FlexiHeat ATEX heater as a solution. The heater is compact, powerful, and portable, allowing it to be used in different locations and configurations. It is ATEX certified for safety in hazardous environments and has an efficient heating element design. The heater can help problems like insufficient temperatures for painting, composite repairs not curing properly, and condensation or freezing of machinery.
This document provides specifications for Nexans 6350/11000 Volt XLPE cables with stranded copper conductors and copper wire screens for UK Power Networks. The cables come in nominal cross-sectional areas from 300 to 800 mm2. Key specifications include approximate diameter, thickness of insulation and sheath, number of copper wire screens, capacitance, resistance, inductance, and short circuit ratings.
Vulcan + cable cleats are designed for trefoil, single, quad and bundled cable applications where moderate short circuit withstand is required. They have a compact, patented design that allows for easy installation in spaces with limited space. The cleats are made of stainless steel to withstand harsh environments and include a polymeric liner and removable base pad to protect cables during short circuits. They have passed testing for impact resistance, resistance to electro-mechanical forces, and can withstand temperatures from -40 to 60 degrees Celsius.
The Roxtec BGTM product family is designed to safely and efficiently bond or ground armored and shielded cables through a single cut-out or open- ing in a wall, floor or electrical enclosure. The product provides a secure means of cable terminations and pass-throughs, provides an environmental and fire resistant seal, and establishes a secure bonding path to ground for metallic cable components. The product is certified for use in hazardous locations where required by local codes and regulations. The Roxtec BGTM system complies with EU directive 2002/95/EC, Restriction of Hazardous Substances (RoHS).
This document is an electrical product catalogue from Ellis that includes information about various cable cleat products. It summarizes that Ellis cable cleats are tested to high standards to guarantee they will contain short-circuit forces and protect infrastructure. The catalogue then provides details on specific cleat product lines including Alpha, Emperor and Vulcan+ cleats. It describes the materials, maximum short-circuit test levels, recommended spacing and fixing for each product. Dimensions, weights and part numbers are shown in selection tables.
The document provides information on cable cleats, including:
- What cable cleats are and why they are necessary to restrain cables and prevent movement from fault currents.
- International standards that specify cable cleats must withstand electromagnetic forces from faults and be rated for cable size and current.
- Short-circuit testing is outlined as the best way to test cable cleats' ability to withstand fault conditions, and the IEC standard's methodology is described.
- A formula from the IEC standard is presented to calculate cable cleat spacing based on fault level and cable size.
This document provides information about G&W Electric's cable accessories, including:
1. G&W Electric manufactures cable accessories such as terminations and joints rated from 69kV to 230kV for extruded dielectric cable systems.
2. The accessories are factory molded and tested, and installation options include mechanical shrink or slip on methods.
3. G&W Electric has certification for its products and testing facilities to ensure product quality and reliability.
Roxtec Cable Transits - Installing & Terminating Substation Cables
Roxtec cable transits provide several clear advantages for installing and terminating cables in industrial and high voltage substations. Roxtec cable transits provide a standardised design with the flexibility to terminate a variety of different sizes and cable constructions. The ease of cable installation reduces labour costs and minimises the potential for cable insulation damage. The structural and environmental integrity of the wall or floor penetration is maintained providing an insulated, vapor-tight and fire-stop barrier and cables can be easily added for future up-grading. Roxtec cable transits are a viable alternative for terminating cables into industrial power substations.
The document is a catalogue from Nexans that describes their Euromold division and the products they offer. Euromold specializes in prefabricated cable accessories for medium voltage energy distribution, including connectors, joints, bushings and terminations from 12-42kV. The catalogue provides information on their separable connectors, including tee connectors in different voltage classes and sizes to connect cables to equipment or other cables. It describes the components, standards, and provides ordering information.
Cembre B135C Hydraulic Crimping Tool - Battery Crimping Tools
14.4V cordless hydraulic battery crimping tool
Lightweight and balanced Cembre crimper for single hand operation
Double speed crimping action
Cembre crimping head can rotate through 180°
Quiet in operation with very little vibration
Operating buttons mechanically interlocked to prevent accidental operation
Microprocessor control with automatic motor cut out on completion of the crimping operation
Fitted with a maximum hydraulic pressure valve
Cembre B135C Battery Crimpers - Crimping Applications
HV & LV cable lugs - 400sqmm
HV & LV cable splices - 240sqmm
Insulated cable terminals - 240sqmm
C Sleeve connectors - 185sqmm
The document is a 2014 catalogue from Nexans Network Solutions Division Euromold. It provides information on Euromold's medium voltage cable accessories, including:
- Euromold is a leading European manufacturer and distributor of prefabricated cable accessories for medium voltage energy distribution, providing a complete range of accessories for underground cables.
- The catalogue describes Euromold's ISO 9001 certification and independent laboratory accreditation, and notes that all products meet international standards.
- It provides specifications, diagrams and ordering information for various separable connectors and equipment bushings, including elbow connectors, tee connectors, and equipment bushings for interfaces up to 36kV and 400A.
This document is a catalogue from Nexans Network Solutions Div. Euromold that provides information on cable accessories. It describes various prefabricated cable accessories that Euromold manufactures for medium voltage energy distribution, including premoulded EPDM rubber connectors for cables and epoxy bushings. It provides details on Euromold's ISO 9001 and laboratory accreditation certification. The document also includes specifications for separable connectors like the 158LR elbow connector and 152SR straight connector that are designed to connect cables to equipment up to 24kV and 250A. It provides ordering information and diagrams for these connectors.
This document provides information on Euromold's medium voltage symmetrical separable connectors, including the Interface C connectors. It describes the 400LB elbow connector, 400TB and 440TB tee connectors, their design, specifications, standards, kit contents and ordering instructions. Euromold is a leading European manufacturer and distributor of prefabricated cable accessories for medium voltage energy distribution.
This document provides installation instructions for heatshrink joints for fire resistant XLPE/SWA/LSOH or EPR/GSB cables with 3 to 5 cores and voltages of 0.6/1kV. The instructions specify preparing the cable ends according to dimensions in a table. Conductors are exposed and connected, then insulation tubes are positioned and shrunk. Fire barrier tape and an inner shrink tube are applied over the connections. Copper mesh and an outer shrink tube are wrapped around the joint and secured. A fire barrier tube is slid over and fastened with roll springs.
Ellis Patents Alpha cable cleats are available for trefoil and single cable applications where moderate levels of short circuit withstand are required. Ellis Patents Alpha cable cleats unique design allows rapid installation offering significant man hours and labour saving for cable contractors.
Ellis Patents Alpha cable cleats are compliant with London Underground Engineering Standard 1-085 - Product Register No.360.
Alpha cable cleats are manufactured from extruded aluminium (6000 series) to BS EN 755, the cleat is lighter and tougher than the cast aluminium cable cleat product it is designed to replace - cleats are supplied with zinc plated closing fasteners.
The document provides an overview of the LS 4000i Series scanners:
- It describes the different scanner models in the LS 4000i Series (LS 4004i, LS 4005i, LS 4006i, LS 4007i) and how to set them up for scanning barcodes.
- It discusses connecting the scanners to a host system for 1-D or 2-D barcode scanning and transmitting scan data.
- It includes specifications for the scanners as well as maintenance instructions and parameter settings.
The APP pumps provide unsurpassed efficiency and great flexibility for configuration. The simple construction of the axial piston pump with fewer parts allows highly reliable operation with long service intervals and easy maintenance.
Motorola solutions wing 4.4 ap51xx access point product reference guide (part...Advantec Distribution
This document provides a product reference guide for the Motorola Solutions AP 5131 wireless access point. It includes sections on new features of the AP 5131 such as WIPS support, trusted host management, and adaptive AP functionality. The guide also covers an overview of the AP 5131's features which include dual radio options, separate LAN and WAN ports, mounting options, quality of service support, security, management access and more. It provides information on the device's capabilities and specifications.
This document provides an overview of a European Commission-funded project called AC/DC that aims to advance the automotive industry through collaboration and modularity. The project supports the transition from build-to-order to customize-to-order production approaches. Key contributions of the project include the development of smart modular products like an innovative rear axle module, methods for collaborative production network management called Dynamic Supply Loops, and making production systems more flexible. The document provides details on the technical components developed and results of applying the new approaches, which achieved strategic objectives like reducing lead times and inventory.
This document provides the user manual for MicroLogix 1500 programmable controllers. It contains important safety information and describes the various hardware components of the MicroLogix 1500 system, including base units, processors, memory modules, I/O modules, cables, and more. The document provides instructions for installing, wiring, and programming the controllers. It also includes agency certifications, technical specifications for the components, and wiring diagrams.
This document provides the user manual for MicroLogix 1500 programmable controllers. It contains important safety information and describes the hardware components, installation, wiring, and programming of MicroLogix 1500 controllers. The manual instructs users on agency certifications, safety considerations, mounting the controller, installing components, wiring requirements, and using expansion I/O modules. It is intended to guide users through setting up and implementing MicroLogix 1500 programmable logic controllers.
This document provides the user manual for MicroLogix 1500 programmable controllers. It contains important safety information and describes the hardware components, installation, wiring, and programming of the MicroLogix 1500 system. The manual instructs users on agency certifications, safety considerations, mounting the controller, installing components, wiring requirements, and using expansion I/O modules. It is intended to guide users through setting up and implementing a MicroLogix 1500 programmable logic controller system.
Motorola ap650 access point installation guide (part no. 72 e 131207-01 rev. d )Advantec Distribution
The document provides instructions for installing the Motorola AP-650 Thin Access Point, which can be mounted on a wall or suspended ceiling. It includes details on package contents, placement guidelines, wall and ceiling mounting procedures, and specifications. The integrated antenna model mounts using wall screws or clips on a suspended ceiling T-bar. The external antenna model also mounts on walls or ceilings and has options for external antenna connections.
Motorola ap650 access point installation guide (part no. 72 e 131207-01 rev. d )Advantec Distribution
The document provides installation instructions for the Motorola AP-650 Series Thin Access Point. It includes details on package contents, features, hardware installation instructions for wall and ceiling mounts, specifications, regulatory information, and customer support resources. Wall and ceiling mount options are described along with required hardware. Status indicators and technical specifications are listed.
The document provides installation instructions for the Motorola AP-650 Thin Access Point. It can be mounted on a wall or suspended ceiling and is available with integrated or external antennas. The document describes the package contents, features, wall and ceiling mounting procedures, specifications, regulatory information, and support resources. Installation requires attaching the access point to a wall or ceiling using the provided hardware and connecting an Ethernet cable from the access point to a switch with 802.3af power.
The document provides installation instructions for the Motorola AP-650 Thin Access Point. It can be mounted on a wall or suspended ceiling and comes in integrated antenna and external antenna models. The instructions describe the package contents, recommended placement, and step-by-step procedures for wall mounting or mounting on a suspended ceiling T-bar for both antenna models. Specifications and regulatory information are also included.
Motorola solutions wing 4.4 ap7131 n access point product reference guide (pa...Advantec Distribution
The document provides reference information about the Motorola Solutions AP 7131N product. It includes a revision history and covers new features of the WiNG 4.4 firmware, an overview of the AP's key features such as 802.11n support, sensor capabilities, security features, and management options. The document is intended to help users understand and configure the capabilities of the AP 7131N.
Motorola solutions wing 4.4 ap7131 n access point product reference guide (pa...Advantec Distribution
The document provides reference information about the Motorola Solutions AP 7131N product. It includes a revision history and covers new features of the device such as power management antenna configuration, hotspot customization, and WAN failover. The main sections describe the device's features, which include 802.11n support, sensor capabilities, mesh networking, security, management options and more. Revision notes indicate the manual was updated to the WiNG 4.4 baseline.
This document is a product reference guide for the LS 9208 scanner. It contains information about setting up, using, maintaining and specifying the technical details of the scanner. The guide includes chapters on getting started with setup and configuration, scanning functionality, maintenance, technical specifications, and customizing user preferences. It provides instructions and definitions for key aspects of using the scanner such as interface connection, scanning modes, beeper tones, LED indicators, aiming and decoding performance.
This document provides an overview and user manual for the MicroLogix 1200 programmable controller. It describes the hardware features and components of the MicroLogix 1200 including the controller, expansion I/O, communication cables, and programming options. The document provides safety and installation instructions including mounting, wiring, communication connections and specifications for the MicroLogix 1200 controller and expansion I/O modules.
Product description vital qip next generation v7 2_en_feb09(1)Roy Muy Golfo
VitalQIP is a leading IP management software that provides centralized management of IP addresses, DNS, DHCP, and ENUM. It offers automated IP address assignment, accurate network inventory, flexible user interfaces, redundancy of DNS and DHCP servers, and integration with existing DNS and DHCP environments. The document provides an overview of VitalQIP's capabilities, including its architecture with enterprise server, database, and client components. It describes the user interfaces of the core product, such as the new next-generation web GUI, command line interface, and web services API. The document also outlines many features of VitalQIP related to DNS, DHCP, reporting, user permissions, and high availability.
This document provides a summary of the HiPath 4000 V6 system software components, including:
- Descriptions of hardware configurations, licensing, applications, and the hard disk layout.
- Details on the HiPath 4000 Assistant, including its applications, user accounts, and notification mechanisms.
- An overview of the HiPath 4000 CSTA software component.
The document contains technical information on the various software aspects that make up the HiPath 4000 V6 communication system.
This document provides installation instructions for the AP-8222 Access Point. It includes guidelines for site preparation, package contents, hardware installation including wall or ceiling mounting, connecting the power injector system, and basic configuration of the access point. The document also provides specifications, regulatory information, and support contact details for the AP-8222.
This document provides product specifications for SanDisk's CloudSpeed 1000 and CloudSpeed 1000E 2.5-inch SATA solid state drives. It includes details on features like performance, reliability, environmental conditions, mechanical specifications, electrical interface, and compliance. The drives use flash management techniques like aggregated flash management and advanced signal processing to provide high endurance and reliability. Temperature throttling helps ensure operation within specified environmental conditions.
This technical specification provides guidelines for the design, installation, testing and maintenance of main earthing systems in substations. It covers the function and features of earthing systems, safety criteria to protect against electric shock, design considerations such as soil resistivity and fault currents, installation of conductors and electrodes, testing of the system, and maintenance. The document aims to help engineers properly earth metalwork at substations to ensure safety and reliability of supply.
Similar to SP Energy Networks Approved Equipment Register - LV MV Joints & Terminations (2014) (20)
Isolation Procedures for Safe Working on Electrical Systems and Equipment by the JIB | solation Procedures for Safe Working on Electrical Systems and Equipment
This chart shows the safe isolation procedure that you should use when working on electrical systems and equipment.
You'll receive a printed copy of this from your Training Provider, but it's also here as a handy reference to keep electronically.
THE RULES OF SAFE ISOLATION ARE:
Obtain permission to start work (a Permit may be required in some situations)
Identify the source(s) of supply using an approved voltage indicator or test lamp
Prove that the approved voltage indicator or test lamp is functioning correctly
Isolate the supply(s)
Secure the isolation
Prove the system/equipment is DEAD using an approved voltage indicator or test lamp
Prove that the approved voltage indicator or test lamp is functioning correctly
Put up warning signs to tell other people that the electrical installation has been isolated
Once the system/equipment is proved DEAD, work can begin
Uploaded by THORNE & DERRICK LV HV Jointing, Earthing, Substation & Electrical Eqpt | Explosive Atmosphere Experts & ATEX IECEx.
Thorne & Derrick International are specialist distributors of low, medium, and high voltage cable installation, jointing, substation, and electrical equipment. They have over 30 years of experience and stock over 100,000 products from over 100 brands. Their product range includes cable joints, terminations, tools, accessories, distribution equipment, and safety products for voltages up to 132kV.
The document advertises the Children North East Annual Golf Day fundraising event to be held on May 9th, 2018 at Close House golf course in Northumberland. The event will include a shotgun start at 2pm for teams of four playing in a Stableford scoring competition. The £490 entry fee per team includes breakfast, a two course meal after play, and goodie bags. Proceeds will benefit Children North East, a charity supporting children in the Newcastle region.
This document provides information on 3M's electrical products, including electrical connectors, wire connectors, splice kits, wire markers, and protective coatings. It highlights key features and applications of 3M's Scotchlok electrical insulation displacement connectors, Performance Plus wire connectors, direct bury splice kits, ScotchCode wire markers, insulating and anti-corrosion sprays, and Scotchkote electrical coating. The document is intended to showcase 3M's quality solutions for electrical connections, identification, and corrosion protection.
This document provides a catalogue of products from SICAME GROUP for electrical safety. It begins by emphasizing the importance of electrical safety for professionals working in the electrical industry. The catalogue then outlines the company's commitment to supporting customers through new products designed by their teams, an updated catalogue focusing on product functions and uses, and new educational tools like guidance documents. The bulk of the document consists of the catalogue content organized into sections covering personal protective equipment, locking, signaling, low voltage test and measurement, low voltage earthing systems, low voltage live working tools, medium voltage substation equipment, medium voltage equipment, high voltage lines and switchgear equipment, and earthing connections. Each section lists and provides brief descriptions of the various safety products
1) The document provides installation instructions for heatshrink termination of 3 core polymeric cables with voltages ranging from 7.2kV to 36kV. It describes the steps for preparing the cable, installing stress control tapes and tubes, cable lugs, and rain sheds.
2) Key steps include removing the cable sheath and screens, applying stress control tape, installing cable lugs and boots, and shrinking tubes onto the assembly. Proper distances must be maintained for phase clearance and bending radii.
3) Outdoor terminations require additional rain sheds installed from the bottom up at specified distances between the anti-track tube and shed edges. Indoor distances between phases and grounds are also outlined.
THORNE & DERRICK based in the UK are international distributors of LV, MV & HV Cable Installation, Jointing, Substation & Electrical Equipment.
Since 1985, T&D have established an international reputation based on SERVICE | INTEGRITY | TRUST.
Contact us for 3M, ABB, Alroc, AN Wallis, CATU, Cembre, Centriforce, CMP, CSD, Elastimold, Ellis Patents, Emtelle, Euromold, Filoform , Furse, Lucy Electric & Zodion, Nexans, Pfisterer, Polypipe, Prysmian, Roxtec, Sicame, WT Henley.
The document provides technical specifications for EJB series explosion proof enclosures made of galvanized carbon steel. The enclosures have an IP rating of IP65, IP66, or IP67 and an operating temperature range of -50°C to +60°C. They offer explosion protection of Ex d IIB or IIB+H2 and are suitable for indoor and outdoor use in hazardous industrial areas. The enclosures can house various electrical and electronic components and accessories.
This certificate of attendance awards Adam Rowe and Michael Wenglorz for successfully completing a SIL (Safety Integrity Level) training seminar held by PEPPERL+FUCHS GB LTD on November 7th, 2016.
Thorne & Derrick were established in 1985 and are now one of the largest specialist distributors and worldwide exporters of equipment for explosive atmospheres. They stock over 100,000 products from over 100 brands for industries such as oil & gas, mining, manufacturing, and more. Thorne & Derrick provide hazardous area lighting, heating, sensors, detectors, valves, cables, and other equipment certified for explosive atmospheres. They also offer technical support, international delivery, and over 30 years of experience in serving hazardous area applications.
This document is an application datasheet for flow measurement devices. It requests contact and process information from customers. It asks for details about the application environment and pipe parameters. It also requests information on process parameters like temperature, pressure, and flow rates. Finally, it inquires about desired measurement configuration including units of measurement, data logging, power supply, and electrical and communication interfaces.
This document provides information on Emtelle fibre optic cables, including:
- An overview of Emtelle as a leading global manufacturer of blown fibre and ducted network solutions.
- Descriptions of different cable types including Direct Install, Direct Buried, Aerial, and more.
- Specifications for various cable models including fibre count options, dimensions, tensile strength and other test standards.
Thorne & Derrick provide electrical heating solutions for industrial and hazardous area applications. They have over 30 years of experience in process heating and specialize in frost protection and winterization packages. They offer a wide range of electrical heating equipment for hazardous areas, including portable air heaters certified for use in explosive atmospheres. Their product range and engineering expertise help customers solve heating challenges across various industries.
The document provides information on tools for preparing electric utility distribution and transmission cables. It includes tools for stripping insulation from secondary distribution cables, mid-span stripping of overhead primary distribution cables, insulation stripping and jacket stripping for underground cables, removing insulation shields from underground and transmission cables, pencilling transmission cables, and other specialty distribution tools. Tables provide part numbers and specifications for various cable end strippers and other tools to prepare different cable types.
The document describes the RIDGID micro CD-100 combustible gas leak detector. It can quickly identify the presence of combustible gases with a flexible 41 cm probe. It is designed to detect gases like methane, propane, and more. The micro CD-100 has adjustable sensitivity settings and Tri-Mode Detection that provides alerts through visual, audible or vibration signals. It is listed as catalog number 36163 and weighs 0.45 kg.
Itron is a leading technology company dedicated to measuring, managing, and analyzing energy and water resources. It provides comprehensive solutions including meters, communication systems, software, and consulting services to over 8,000 customers in more than 100 countries. Itron employs thousands of people globally and invests over 8.5% of its $1.9 billion annual revenue in research and development.
The FiloSeal+HD is a duct sealing system that uses hexagonal tubes and a flexible silicon-based sealant to seal cable configurations and pipes within conduits. It provides resistance to up to 2 bars of pressure and can withstand pulling forces of 100kg on sealed cables. The sealant is easily applied and cures with air, providing high levels of gas and water tightness. The system allows for easy addition or removal of cables or pipes as needed.
Getting the Most Out of ScyllaDB Monitoring: ShareChat's TipsScyllaDB
ScyllaDB monitoring provides a lot of useful information. But sometimes it’s not easy to find the root of the problem if something is wrong or even estimate the remaining capacity by the load on the cluster. This talk shares our team's practical tips on: 1) How to find the root of the problem by metrics if ScyllaDB is slow 2) How to interpret the load and plan capacity for the future 3) Compaction strategies and how to choose the right one 4) Important metrics which aren’t available in the default monitoring setup.
What is an RPA CoE? Session 2 – CoE RolesDianaGray10
In this session, we will review the players involved in the CoE and how each role impacts opportunities.
Topics covered:
• What roles are essential?
• What place in the automation journey does each role play?
Speaker:
Chris Bolin, Senior Intelligent Automation Architect Anika Systems
The Department of Veteran Affairs (VA) invited Taylor Paschal, Knowledge & Information Management Consultant at Enterprise Knowledge, to speak at a Knowledge Management Lunch and Learn hosted on June 12, 2024. All Office of Administration staff were invited to attend and received professional development credit for participating in the voluntary event.
The objectives of the Lunch and Learn presentation were to:
- Review what KM ‘is’ and ‘isn’t’
- Understand the value of KM and the benefits of engaging
- Define and reflect on your “what’s in it for me?”
- Share actionable ways you can participate in Knowledge - - Capture & Transfer
inQuba Webinar Mastering Customer Journey Management with Dr Graham HillLizaNolte
HERE IS YOUR WEBINAR CONTENT! 'Mastering Customer Journey Management with Dr. Graham Hill'. We hope you find the webinar recording both insightful and enjoyable.
In this webinar, we explored essential aspects of Customer Journey Management and personalization. Here’s a summary of the key insights and topics discussed:
Key Takeaways:
Understanding the Customer Journey: Dr. Hill emphasized the importance of mapping and understanding the complete customer journey to identify touchpoints and opportunities for improvement.
Personalization Strategies: We discussed how to leverage data and insights to create personalized experiences that resonate with customers.
Technology Integration: Insights were shared on how inQuba’s advanced technology can streamline customer interactions and drive operational efficiency.
In our second session, we shall learn all about the main features and fundamentals of UiPath Studio that enable us to use the building blocks for any automation project.
📕 Detailed agenda:
Variables and Datatypes
Workflow Layouts
Arguments
Control Flows and Loops
Conditional Statements
💻 Extra training through UiPath Academy:
Variables, Constants, and Arguments in Studio
Control Flow in Studio
AI in the Workplace Reskilling, Upskilling, and Future Work.pptxSunil Jagani
Discover how AI is transforming the workplace and learn strategies for reskilling and upskilling employees to stay ahead. This comprehensive guide covers the impact of AI on jobs, essential skills for the future, and successful case studies from industry leaders. Embrace AI-driven changes, foster continuous learning, and build a future-ready workforce.
Read More - https://bit.ly/3VKly70
Discover the Unseen: Tailored Recommendation of Unwatched ContentScyllaDB
The session shares how JioCinema approaches ""watch discounting."" This capability ensures that if a user watched a certain amount of a show/movie, the platform no longer recommends that particular content to the user. Flawless operation of this feature promotes the discover of new content, improving the overall user experience.
JioCinema is an Indian over-the-top media streaming service owned by Viacom18.
Introducing BoxLang : A new JVM language for productivity and modularity!Ortus Solutions, Corp
Just like life, our code must adapt to the ever changing world we live in. From one day coding for the web, to the next for our tablets or APIs or for running serverless applications. Multi-runtime development is the future of coding, the future is to be dynamic. Let us introduce you to BoxLang.
Dynamic. Modular. Productive.
BoxLang redefines development with its dynamic nature, empowering developers to craft expressive and functional code effortlessly. Its modular architecture prioritizes flexibility, allowing for seamless integration into existing ecosystems.
Interoperability at its Core
With 100% interoperability with Java, BoxLang seamlessly bridges the gap between traditional and modern development paradigms, unlocking new possibilities for innovation and collaboration.
Multi-Runtime
From the tiny 2m operating system binary to running on our pure Java web server, CommandBox, Jakarta EE, AWS Lambda, Microsoft Functions, Web Assembly, Android and more. BoxLang has been designed to enhance and adapt according to it's runnable runtime.
The Fusion of Modernity and Tradition
Experience the fusion of modern features inspired by CFML, Node, Ruby, Kotlin, Java, and Clojure, combined with the familiarity of Java bytecode compilation, making BoxLang a language of choice for forward-thinking developers.
Empowering Transition with Transpiler Support
Transitioning from CFML to BoxLang is seamless with our JIT transpiler, facilitating smooth migration and preserving existing code investments.
Unlocking Creativity with IDE Tools
Unleash your creativity with powerful IDE tools tailored for BoxLang, providing an intuitive development experience and streamlining your workflow. Join us as we embark on a journey to redefine JVM development. Welcome to the era of BoxLang.
ScyllaDB is making a major architecture shift. We’re moving from vNode replication to tablets – fragments of tables that are distributed independently, enabling dynamic data distribution and extreme elasticity. In this keynote, ScyllaDB co-founder and CTO Avi Kivity explains the reason for this shift, provides a look at the implementation and roadmap, and shares how this shift benefits ScyllaDB users.
Session 1 - Intro to Robotic Process Automation.pdfUiPathCommunity
👉 Check out our full 'Africa Series - Automation Student Developers (EN)' page to register for the full program:
https://bit.ly/Automation_Student_Kickstart
In this session, we shall introduce you to the world of automation, the UiPath Platform, and guide you on how to install and setup UiPath Studio on your Windows PC.
📕 Detailed agenda:
What is RPA? Benefits of RPA?
RPA Applications
The UiPath End-to-End Automation Platform
UiPath Studio CE Installation and Setup
💻 Extra training through UiPath Academy:
Introduction to Automation
UiPath Business Automation Platform
Explore automation development with UiPath Studio
👉 Register here for our upcoming Session 2 on June 20: Introduction to UiPath Studio Fundamentals: https://community.uipath.com/events/details/uipath-lagos-presents-session-2-introduction-to-uipath-studio-fundamentals/
Lee Barnes - Path to Becoming an Effective Test Automation Engineer.pdfleebarnesutopia
So… you want to become a Test Automation Engineer (or hire and develop one)? While there’s quite a bit of information available about important technical and tool skills to master, there’s not enough discussion around the path to becoming an effective Test Automation Engineer that knows how to add VALUE. In my experience this had led to a proliferation of engineers who are proficient with tools and building frameworks but have skill and knowledge gaps, especially in software testing, that reduce the value they deliver with test automation.
In this talk, Lee will share his lessons learned from over 30 years of working with, and mentoring, hundreds of Test Automation Engineers. Whether you’re looking to get started in test automation or just want to improve your trade, this talk will give you a solid foundation and roadmap for ensuring your test automation efforts continuously add value. This talk is equally valuable for both aspiring Test Automation Engineers and those managing them! All attendees will take away a set of key foundational knowledge and a high-level learning path for leveling up test automation skills and ensuring they add value to their organizations.
"$10 thousand per minute of downtime: architecture, queues, streaming and fin...Fwdays
Direct losses from downtime in 1 minute = $5-$10 thousand dollars. Reputation is priceless.
As part of the talk, we will consider the architectural strategies necessary for the development of highly loaded fintech solutions. We will focus on using queues and streaming to efficiently work and manage large amounts of data in real-time and to minimize latency.
We will focus special attention on the architectural patterns used in the design of the fintech system, microservices and event-driven architecture, which ensure scalability, fault tolerance, and consistency of the entire system.
"Frontline Battles with DDoS: Best practices and Lessons Learned", Igor IvaniukFwdays
At this talk we will discuss DDoS protection tools and best practices, discuss network architectures and what AWS has to offer. Also, we will look into one of the largest DDoS attacks on Ukrainian infrastructure that happened in February 2022. We'll see, what techniques helped to keep the web resources available for Ukrainians and how AWS improved DDoS protection for all customers based on Ukraine experience
"What does it really mean for your system to be available, or how to define w...Fwdays
We will talk about system monitoring from a few different angles. We will start by covering the basics, then discuss SLOs, how to define them, and why understanding the business well is crucial for success in this exercise.