GREENBUILDINGSBY:LOKESH ZOPE – 0715048PROJECT GUIDE: PROF. V. S. NARWANE
WHY DO WE NEED TO THINK ABOUT BUILDINGS?Buildings consume almost one-third of the total energy produced
 Problems of energy crisis are impending
Buildings are the places where humans spend    their maximum time  A conducive environment to work is always beneficial for efficient work output
RESOURCE OPTIMIZATIONHUMAN COMFORT
SOLAR GRID-TIE CONNECTIONSUN
HOW TO SIZE?SYSTEM REQUIREMENTINVESTMENT
ORIENTATIONSUNPATHAZIMUTH ANGLE:Ø
IV CURVE FOR SOLAR PHOTO-VOLTAICIV curve of Solar Photo-Voltaic Operating Point
 Maximum Power Point Trackers
DESIGN PROCEDURE
1. SYSTEM SIZINGPac =        Power required (KWh/yr)                  = 620000           =340KW           Hours/day of 1Sun x 365 days/yr               5 x 365Pdcstc =                 Pac                          =         340/0.97 = 350KW                 Conversion Efficiency
2. ORIENTATIONNTilt angle = 90 – βNWhere, βN= 90° - L + δ               δ = 23.45 sin[(360/365)(n-81)]
TILT ANGLEOPTIMUM ANGLE: 18.82°
3.1 SELECTION OF PANELS
3.2 SELECTION OF INVERTER
4. ECONOMICSTotal investment = Cost of inverter + cost of panels + cost of connectors + cost of module maintenance systems + installation charges Cost of inverters: $4000 x 35 = Rs. 6.5 croreCost of solar photovoltaic panels: Rs.23700 x 1155 = Rs. 2.7 crore Total cost: Rs. 9.2 croreApproximately total investment: Rs. 10 CroreThe total cost spent in buying power per year: Rs. 72,00,000 Total money saved: First 5 years: full efficiency (i.e. the system will provide entire power)                      Rs. 72,00,000 x 5 = Rs. 3.6 Crore Next 7 years: 90% efficiency                       Rs.72,00,000 x 0.9 x 7 = Rs. 4.536 Crore Next 13 years: 80% efficiency                      Rs. 72,00,000 x 0.8 x 13 = Rs. 7.488 Crore (The company of the panels provide the product guarantee of above efficiencies)Total saving for 25 years after installation: Rs. 15.622 Crore   Inflation rate of   cost of power   Investment gains
105ARRAY11300W    x    1155 Panels    :     346 KW      :    11 x 10511 Panels   :    Max voltage: 36.86 x 11 = 405VInverter Input Voltage :  300V – 600V35
HUMAN COMFORT Human body = Heat producing machine
 Q = m. Cv. δT
  Forced convectionUSAGE OF COMPUTATIONAL FLUID DYNAMICSFinite element method Modeling
 Fluid flow conditions
 Include temperature, velocity, pressure
 Find stagnation point
 Find pathlines
 Strategically placing chimneys and inlets and outlets
 Re-modelingDEPARTMENTAL LIBRARY N
ROOM MODELLING IN ICEM-CFD
MESH
MESH CUT PLANE
MESH TOP VIEW

Project green buildings (be)

Editor's Notes

  • #3 Just not seeing the smoke doesn’t mean that there is no pollutionIndia produces electricity majorly from coal and the availability of reserves say that for atleast next 50 years India will be using coal
  • #20 Human body analogous to heat producing machine which has to keep on emitting heat in order to feel comfortable, Either the air can be conditioned or the air flow can be increased, Since ventilation analysis of entire building is not feasible, ventilation analysis of Departmental office is done in the project