The document describes Nautica's Multiple Small Plate (MSP) dehumidification technology. MSP technology uses small plate heat exchangers and smaller compressors to pre-cool and partially dehumidify incoming air, allowing larger dehumidification capacity with 50% lower energy costs than conventional systems. Nautica offers MSP technology in air handling units and fanless modules for various indoor applications, including food processing, hospitals, schools, and more.
AirMotion Big Smart Fans help increase productivity and efficiency in facilities by enhancing comfort and reducing HVAC costs. They are designed to move large volumes of air throughout facilities using little energy. Key features include variable blade pitch for adjustable air flow, energy efficient operation, and automatic controls to optimize performance based on temperature.
The document discusses a modular cooling solution for data centers as an alternative to traditional CRAC-based cooling. It presents the modular cooling unit design, which uses refrigerant to transfer heat directly from racks to the external environment. A case study shows the solution reduced server temperatures in a lab by up to 14 degrees F compared to CRAC cooling, while also improving data center space utilization. The business case analysis finds that the modular solution saves on energy costs and has a payback period of 3.3 years compared to traditional CRAC units for a sample data center.
Workstation heat, sound, and power usage: Lenovo ThinkStation D30 vs. Dell Pr...Principled Technologies
A workstation that runs quietly and cooly and uses less power is a great boon to workers and the companies they work for. In our tests, both when idle and when under load, the Lenovo ThinkStation D30 generally ran at lower surface temperatures than the Dell Precision T7600 and ran more quietly. The Lenovo ThinkStation D30 also used less power when idle. These findings show that the Lenovo ThinkStation D30 could meet the needs of those who want to provide a reliable, comfortable work environment while using less power.
R90 160 - global - a4 - 2010 v3-a_dong jscDinh Van Vinh
This document provides information on Ingersoll Rand's R-Series contact-cooled rotary screw air compressors ranging from 90-160 kW (125-200 hp). It highlights features such as the Progressive Adaptive Control system which monitors operating parameters, the sequential cooling system for improved efficiency and serviceability, and V-Shield leak-free piping technology. Performance specifications including flow rates and dimensions are listed for various compressor models.
To help our customers make saving and generating revenue from Clean air, Clean coolant Clean workspaces and Profitable recovery while improving the environments
HeatWork provides heating and thawing systems that allow construction projects to continue throughout the winter. Their systems thaw ground frost rapidly and effectively using flexible heating hoses laid directly on the ground. Customers benefit from being able to work year-round without delays or staff layoffs, gaining a competitive advantage over other operators who must wait for frost to thaw naturally. HeatWork machines are reliable, profitable due to low operating costs, and environmentally-friendly alternatives to other thawing methods. Satisfied customers in the construction industry have used HeatWork systems to stay on schedule and avoid winter downtime.
The document discusses Carrier Performance Series humidifiers. It notes that overly dry winter air can cause health issues and humidifiers add comfort by putting moisture back in the air. The humidifiers are efficient and effective by allowing users to feel comfortable at lower thermostat settings, improving air quality and reducing static electricity. They are also durable with corrosion resistant casing and include a five-year limited warranty. The humidifiers have easy to clean treated pads and operate quietly through precision tuned fans and motors or furnace blowers.
Delta Cooling Towers manufactures non-corrosive cooling towers made of high density polyethylene. They offer standard features like corrosion-proof construction and non-clog water distribution. Options include fans, ladders, pumps, and control panels. Delta has over 30 years of experience and provides customized solutions. They can supply a complete cooling system and have manufacturing capabilities to provide long-lasting towers.
AirMotion Big Smart Fans help increase productivity and efficiency in facilities by enhancing comfort and reducing HVAC costs. They are designed to move large volumes of air throughout facilities using little energy. Key features include variable blade pitch for adjustable air flow, energy efficient operation, and automatic controls to optimize performance based on temperature.
The document discusses a modular cooling solution for data centers as an alternative to traditional CRAC-based cooling. It presents the modular cooling unit design, which uses refrigerant to transfer heat directly from racks to the external environment. A case study shows the solution reduced server temperatures in a lab by up to 14 degrees F compared to CRAC cooling, while also improving data center space utilization. The business case analysis finds that the modular solution saves on energy costs and has a payback period of 3.3 years compared to traditional CRAC units for a sample data center.
Workstation heat, sound, and power usage: Lenovo ThinkStation D30 vs. Dell Pr...Principled Technologies
A workstation that runs quietly and cooly and uses less power is a great boon to workers and the companies they work for. In our tests, both when idle and when under load, the Lenovo ThinkStation D30 generally ran at lower surface temperatures than the Dell Precision T7600 and ran more quietly. The Lenovo ThinkStation D30 also used less power when idle. These findings show that the Lenovo ThinkStation D30 could meet the needs of those who want to provide a reliable, comfortable work environment while using less power.
R90 160 - global - a4 - 2010 v3-a_dong jscDinh Van Vinh
This document provides information on Ingersoll Rand's R-Series contact-cooled rotary screw air compressors ranging from 90-160 kW (125-200 hp). It highlights features such as the Progressive Adaptive Control system which monitors operating parameters, the sequential cooling system for improved efficiency and serviceability, and V-Shield leak-free piping technology. Performance specifications including flow rates and dimensions are listed for various compressor models.
To help our customers make saving and generating revenue from Clean air, Clean coolant Clean workspaces and Profitable recovery while improving the environments
HeatWork provides heating and thawing systems that allow construction projects to continue throughout the winter. Their systems thaw ground frost rapidly and effectively using flexible heating hoses laid directly on the ground. Customers benefit from being able to work year-round without delays or staff layoffs, gaining a competitive advantage over other operators who must wait for frost to thaw naturally. HeatWork machines are reliable, profitable due to low operating costs, and environmentally-friendly alternatives to other thawing methods. Satisfied customers in the construction industry have used HeatWork systems to stay on schedule and avoid winter downtime.
The document discusses Carrier Performance Series humidifiers. It notes that overly dry winter air can cause health issues and humidifiers add comfort by putting moisture back in the air. The humidifiers are efficient and effective by allowing users to feel comfortable at lower thermostat settings, improving air quality and reducing static electricity. They are also durable with corrosion resistant casing and include a five-year limited warranty. The humidifiers have easy to clean treated pads and operate quietly through precision tuned fans and motors or furnace blowers.
Delta Cooling Towers manufactures non-corrosive cooling towers made of high density polyethylene. They offer standard features like corrosion-proof construction and non-clog water distribution. Options include fans, ladders, pumps, and control panels. Delta has over 30 years of experience and provides customized solutions. They can supply a complete cooling system and have manufacturing capabilities to provide long-lasting towers.
Natgraph Infra Red Dryers & Flash CuresNatgraph
The document discusses Natgraph's range of infrared dryers and flash cures used for curing coatings in various industries. It describes the Model P infrared dryers as having shortwave preheat sections and adjustable longwave heating elements, making them suitable for drying individual components. It also describes the medium wave flash cure units as having high efficiency carbon lamps in a vented reflector design for fast drying of textile inks, and being integrated with automatic textile printing machines.
The document summarizes a MediPulse 2342se suction blast cabinet. It is designed to enhance productivity by allowing operators to work seated and concentrates on surface treatment. Key features include safety interlocks, lighting, gloves, and sound insulation. It minimizes floor space and allows convenient glass and filter changes. Common applications include cleaning, deburring, and finishing parts. Specifications list dimensions and air consumption details.
Introduction to Intelligent Power ManagementAdaptec by PMC
Adaptec Intelligent Power Management (IPM) allows disk drives in servers to reduce power consumption by lowering revolutions per minute or stopping spinning altogether during periods of inactivity. It intelligently buffers data to avoid frequent spin-up/down cycles that waste energy. IPM can be built into Adaptec RAID controllers and reduces the energy needed to power and cool disks by up to 70%. Larger server installations with many disks can save thousands per year on energy costs and cooling requirements through IPM.
The document discusses a virtual desktop solution developed by Dataman using Sun Ray thin clients and VMware virtualization. Key points:
1) The solution addresses increasing demands on desktop compute power by centralizing applications and desktops for easier management while using ultra-low power Sun Ray thin clients.
2) VMware virtualizes operating systems, allowing hundreds of desktops to run on a single server. Sun Ray clients require only screen information from the server.
3) Benefits include reduced power costs, easier management and deployment, increased security and data integrity, and improved productivity through features like hot desking.
This document discusses SmartRooms electric radiant heating systems. It provides information on different types of systems including earth storage systems, radiant ceiling panels, floor warming, and architectural series metal heaters. It highlights the energy efficiency and comfort benefits of radiant heating systems compared to forced air. Case studies show the energy savings and lower operating costs that radiant heating can provide for both residential and commercial buildings.
The document describes the Lightstream Scroll UltraCompact II air-cooled chiller family. It provides capacity-matched cooling, precise thermal parameters, and waterflow. It offers extreme energy efficiency with EER up to 3.29, a compact and lightweight design, and optional features like evaporative pre-cooling and heat recovery options. The chillers use scroll compressors, microchannel condenser coils, and EC fans to achieve high performance while minimizing footprint and delivering best-in-class efficiency.
The document discusses InfraStruXure for data centers and close coupling cooling solutions. Close coupling cooling removes heat at the source, requires less fan power, enables variable speed fans, does not require pressurizing floors, addresses varying heat loads, increases system capacity, reduces unit quantities, requires less space, and enables high density configurations. It provides benefits like future proofing, fully utilizing expensive floor space, and reducing costs associated with adding additional racks.
The document discusses cooling challenges for data centers and presents various cooling solutions. Specifically, it notes that cooling now accounts for 60-70% of data center energy costs. It then outlines challenges like increasing power densities and need for efficiency, availability, manageability, and serviceability. Various cooling architectures are presented, including room-based cooling, row-based cooling, and close-coupled cooling. Free cooling options using ambient air are also discussed.
Super inverter epcen08 114-catalogues_english (2)Henry Hollands
The document discusses Daikin's RZQ Super Inverter air conditioning system. It provides high energy efficiency through its use of inverter technology, DC fan motors, and refrigerants like R-410A. The system ensures maximum comfort with stable temperatures and sound levels as low as 43dB. It can connect to various indoor units and offers benefits like reusing existing piping and a operating range of -15°C to 50°C.
1) The document describes a new liquid cooling PC case design that uses a bubble pump instead of an electrical pump to circulate alcohol instead of water for cooling. This simplifies manufacturing and reduces costs, noise, and power consumption compared to traditional designs.
2) The design was tested successfully and can cool high-performance PCs even during extreme overclocking without temperatures exceeding 62 degrees Celsius, with or without the bubble pump running.
3) Production of the new design is estimated to cost $40, making it the cheapest and most efficient cooling solution currently available according to the document.
cooling system in computer -air / water coolingIbrahem Batta
This document discusses different cooling techniques for electronic devices, including air cooling, liquid cooling, and their components. It provides details on heat sinks, thermal interface materials, fans, blowers, and their differences. Liquid cooling uses water to transmit heat more efficiently than air cooling due to water's higher heat capacity and conductivity. While more effective, liquid cooling systems are more expensive, larger, require technical skills, and carry safety risks if leaked.
The document summarizes concrete curing systems from Advanced Curing Technologies. It discusses 5 essential factors for good curing (accurate temperature control, humidity control, recirculation/energy saving, insulation, and time). It describes two basic systems ("The Big Room" and "Individual Lane") and notes each can achieve the same benefits but operate differently. It outlines advantages of the CDS curing system, which independently controls temperature and humidity, and notes this allows customizing conditions for different product types.
The document discusses ways to make data center cooling more efficient and environmentally friendly. It states that cooling accounts for over 63% of data center energy consumption. Various techniques are presented to reduce cooling costs including raising ambient temperatures, implementing hot/cold aisle containment, improving airflow, conducting technology refreshes, and using renewable energy sources like solar power to drive absorption chillers. The bottom line is that applying even a few of these proven techniques can help lower operating costs while freeing up resources.
Eco-efficiency in data center design from a Middle Eastern perspective.
1) The Middle East faces unique challenges for data center design due to rapid development, energy abundance, and an increasing focus on environmental protection.
2) Key aspects of eco-efficient design discussed include power usage effectiveness (PUE) metrics, high-density cabling solutions, hot/cold aisle containment, modular designs, and environmental monitoring systems.
3) Integrating supply chain services can further improve eco-efficiency through reductions in materials, waste, packaging and on-site time/labor.
CoolnSave Technology For Commercial and Residentialmphmark
Greenway Design Group develops and installs automatic pre-cool solutions for HVAC systems to reduce energy consumption and costs. Their Cool-n-Save systems inject micro mist into incoming air to lower temperatures by 30 degrees, improving HVAC efficiency. Studies show the systems can reduce energy use by up to 30% and provide quick returns on investment within a few months. Commercial systems are customized installations managed by professionals, while residential kits are do-it-yourself with all needed parts.
SusPower is a specialized Sustainable cooling technology design-build firm utilizing only German Patented technology. The latest German technology reached its science in the field of cooling and heating in the Middle East and North Africa. The German Cooling Technology has a long history spanning more than thirty years in the industry, the latest cooling and heating system in the world, which is a network water pipes pass through which gives the temperature of the place according to the user’s desire. The SusPower Cooling system can be used in residential, offices, greenhouses, Equestrian Stables, swimming pools, tents, Cold Storage & refrigeration, and most importantly much healthier than the conventional forced air cooling we are accustomed to in the UAE.
The document describes the Climate Wizard, an indirect evaporative air conditioner that provides highly efficient cooling using outside air. It delivers 100% fresh, cooled outside air while greatly reducing energy consumption compared to conventional air conditioning systems. Climate Wizard has a proven track record worldwide and offers flexible configurations for a wide range of industries. It provides benefits such as improved indoor air quality, reduced electrical demand, flexibility for various applications, lower installation costs, and reduced running costs through its innovative indirect evaporative cooling technology.
This document discusses different types of air conditioning systems and technologies. It describes window air conditioning systems, split air conditioning systems, centralized air conditioning systems, and packaged air conditioning systems. It also introduces new technologies like district cooling systems and chilled beam systems. District cooling systems involve a centralized plant that distributes chilled water through underground pipes to multiple buildings. Chilled beam systems use beams suspended from ceilings to circulate chilled water and cool rooms via convection. The document also outlines the basic refrigeration cycle used in air conditioning with its main components: compressor, condenser, expansion valve, and evaporator.
This document discusses different types of air conditioning systems and their components. It describes window air conditioning systems, split air conditioning systems, centralized air conditioning systems, and packaged air conditioning systems. It also discusses new technologies like district cooling systems and chilled beam systems. The cooling cycle/refrigeration cycle is explained through its key components: compressor, condenser, expansion valve, and evaporator. Requirements for coolants used in air conditioning systems are outlined.
High Density Cooling Solutions for the Next Generation Data Center with Jen42U Data Center Solutions
This document discusses various solutions for high density cooling and precision cooling in next generation data centers. It outlines advantages of different in-row precision cooling options that adapt to changing conditions and racks. Integrated cooling solutions are highlighted that provide flexibility and reduce maintenance costs. Additionally, the document discusses using "free air" or "free cooling" from air-side or water-side economizers to significantly reduce operational costs. Finally, it provides tips to beat the heat in server rooms, including selecting efficient racks and accessories, deploying liquid cooling units, using environmental monitoring, and integrating intelligent power management.
Natgraph Infra Red Dryers & Flash CuresNatgraph
The document discusses Natgraph's range of infrared dryers and flash cures used for curing coatings in various industries. It describes the Model P infrared dryers as having shortwave preheat sections and adjustable longwave heating elements, making them suitable for drying individual components. It also describes the medium wave flash cure units as having high efficiency carbon lamps in a vented reflector design for fast drying of textile inks, and being integrated with automatic textile printing machines.
The document summarizes a MediPulse 2342se suction blast cabinet. It is designed to enhance productivity by allowing operators to work seated and concentrates on surface treatment. Key features include safety interlocks, lighting, gloves, and sound insulation. It minimizes floor space and allows convenient glass and filter changes. Common applications include cleaning, deburring, and finishing parts. Specifications list dimensions and air consumption details.
Introduction to Intelligent Power ManagementAdaptec by PMC
Adaptec Intelligent Power Management (IPM) allows disk drives in servers to reduce power consumption by lowering revolutions per minute or stopping spinning altogether during periods of inactivity. It intelligently buffers data to avoid frequent spin-up/down cycles that waste energy. IPM can be built into Adaptec RAID controllers and reduces the energy needed to power and cool disks by up to 70%. Larger server installations with many disks can save thousands per year on energy costs and cooling requirements through IPM.
The document discusses a virtual desktop solution developed by Dataman using Sun Ray thin clients and VMware virtualization. Key points:
1) The solution addresses increasing demands on desktop compute power by centralizing applications and desktops for easier management while using ultra-low power Sun Ray thin clients.
2) VMware virtualizes operating systems, allowing hundreds of desktops to run on a single server. Sun Ray clients require only screen information from the server.
3) Benefits include reduced power costs, easier management and deployment, increased security and data integrity, and improved productivity through features like hot desking.
This document discusses SmartRooms electric radiant heating systems. It provides information on different types of systems including earth storage systems, radiant ceiling panels, floor warming, and architectural series metal heaters. It highlights the energy efficiency and comfort benefits of radiant heating systems compared to forced air. Case studies show the energy savings and lower operating costs that radiant heating can provide for both residential and commercial buildings.
The document describes the Lightstream Scroll UltraCompact II air-cooled chiller family. It provides capacity-matched cooling, precise thermal parameters, and waterflow. It offers extreme energy efficiency with EER up to 3.29, a compact and lightweight design, and optional features like evaporative pre-cooling and heat recovery options. The chillers use scroll compressors, microchannel condenser coils, and EC fans to achieve high performance while minimizing footprint and delivering best-in-class efficiency.
The document discusses InfraStruXure for data centers and close coupling cooling solutions. Close coupling cooling removes heat at the source, requires less fan power, enables variable speed fans, does not require pressurizing floors, addresses varying heat loads, increases system capacity, reduces unit quantities, requires less space, and enables high density configurations. It provides benefits like future proofing, fully utilizing expensive floor space, and reducing costs associated with adding additional racks.
The document discusses cooling challenges for data centers and presents various cooling solutions. Specifically, it notes that cooling now accounts for 60-70% of data center energy costs. It then outlines challenges like increasing power densities and need for efficiency, availability, manageability, and serviceability. Various cooling architectures are presented, including room-based cooling, row-based cooling, and close-coupled cooling. Free cooling options using ambient air are also discussed.
Super inverter epcen08 114-catalogues_english (2)Henry Hollands
The document discusses Daikin's RZQ Super Inverter air conditioning system. It provides high energy efficiency through its use of inverter technology, DC fan motors, and refrigerants like R-410A. The system ensures maximum comfort with stable temperatures and sound levels as low as 43dB. It can connect to various indoor units and offers benefits like reusing existing piping and a operating range of -15°C to 50°C.
1) The document describes a new liquid cooling PC case design that uses a bubble pump instead of an electrical pump to circulate alcohol instead of water for cooling. This simplifies manufacturing and reduces costs, noise, and power consumption compared to traditional designs.
2) The design was tested successfully and can cool high-performance PCs even during extreme overclocking without temperatures exceeding 62 degrees Celsius, with or without the bubble pump running.
3) Production of the new design is estimated to cost $40, making it the cheapest and most efficient cooling solution currently available according to the document.
cooling system in computer -air / water coolingIbrahem Batta
This document discusses different cooling techniques for electronic devices, including air cooling, liquid cooling, and their components. It provides details on heat sinks, thermal interface materials, fans, blowers, and their differences. Liquid cooling uses water to transmit heat more efficiently than air cooling due to water's higher heat capacity and conductivity. While more effective, liquid cooling systems are more expensive, larger, require technical skills, and carry safety risks if leaked.
The document summarizes concrete curing systems from Advanced Curing Technologies. It discusses 5 essential factors for good curing (accurate temperature control, humidity control, recirculation/energy saving, insulation, and time). It describes two basic systems ("The Big Room" and "Individual Lane") and notes each can achieve the same benefits but operate differently. It outlines advantages of the CDS curing system, which independently controls temperature and humidity, and notes this allows customizing conditions for different product types.
The document discusses ways to make data center cooling more efficient and environmentally friendly. It states that cooling accounts for over 63% of data center energy consumption. Various techniques are presented to reduce cooling costs including raising ambient temperatures, implementing hot/cold aisle containment, improving airflow, conducting technology refreshes, and using renewable energy sources like solar power to drive absorption chillers. The bottom line is that applying even a few of these proven techniques can help lower operating costs while freeing up resources.
Eco-efficiency in data center design from a Middle Eastern perspective.
1) The Middle East faces unique challenges for data center design due to rapid development, energy abundance, and an increasing focus on environmental protection.
2) Key aspects of eco-efficient design discussed include power usage effectiveness (PUE) metrics, high-density cabling solutions, hot/cold aisle containment, modular designs, and environmental monitoring systems.
3) Integrating supply chain services can further improve eco-efficiency through reductions in materials, waste, packaging and on-site time/labor.
CoolnSave Technology For Commercial and Residentialmphmark
Greenway Design Group develops and installs automatic pre-cool solutions for HVAC systems to reduce energy consumption and costs. Their Cool-n-Save systems inject micro mist into incoming air to lower temperatures by 30 degrees, improving HVAC efficiency. Studies show the systems can reduce energy use by up to 30% and provide quick returns on investment within a few months. Commercial systems are customized installations managed by professionals, while residential kits are do-it-yourself with all needed parts.
SusPower is a specialized Sustainable cooling technology design-build firm utilizing only German Patented technology. The latest German technology reached its science in the field of cooling and heating in the Middle East and North Africa. The German Cooling Technology has a long history spanning more than thirty years in the industry, the latest cooling and heating system in the world, which is a network water pipes pass through which gives the temperature of the place according to the user’s desire. The SusPower Cooling system can be used in residential, offices, greenhouses, Equestrian Stables, swimming pools, tents, Cold Storage & refrigeration, and most importantly much healthier than the conventional forced air cooling we are accustomed to in the UAE.
The document describes the Climate Wizard, an indirect evaporative air conditioner that provides highly efficient cooling using outside air. It delivers 100% fresh, cooled outside air while greatly reducing energy consumption compared to conventional air conditioning systems. Climate Wizard has a proven track record worldwide and offers flexible configurations for a wide range of industries. It provides benefits such as improved indoor air quality, reduced electrical demand, flexibility for various applications, lower installation costs, and reduced running costs through its innovative indirect evaporative cooling technology.
This document discusses different types of air conditioning systems and technologies. It describes window air conditioning systems, split air conditioning systems, centralized air conditioning systems, and packaged air conditioning systems. It also introduces new technologies like district cooling systems and chilled beam systems. District cooling systems involve a centralized plant that distributes chilled water through underground pipes to multiple buildings. Chilled beam systems use beams suspended from ceilings to circulate chilled water and cool rooms via convection. The document also outlines the basic refrigeration cycle used in air conditioning with its main components: compressor, condenser, expansion valve, and evaporator.
This document discusses different types of air conditioning systems and their components. It describes window air conditioning systems, split air conditioning systems, centralized air conditioning systems, and packaged air conditioning systems. It also discusses new technologies like district cooling systems and chilled beam systems. The cooling cycle/refrigeration cycle is explained through its key components: compressor, condenser, expansion valve, and evaporator. Requirements for coolants used in air conditioning systems are outlined.
High Density Cooling Solutions for the Next Generation Data Center with Jen42U Data Center Solutions
This document discusses various solutions for high density cooling and precision cooling in next generation data centers. It outlines advantages of different in-row precision cooling options that adapt to changing conditions and racks. Integrated cooling solutions are highlighted that provide flexibility and reduce maintenance costs. Additionally, the document discusses using "free air" or "free cooling" from air-side or water-side economizers to significantly reduce operational costs. Finally, it provides tips to beat the heat in server rooms, including selecting efficient racks and accessories, deploying liquid cooling units, using environmental monitoring, and integrating intelligent power management.
MST and Zenith Solar develop concentrated photovoltaic systems to efficiently generate solar electricity. Agam Energy develops highly efficient engine and HVAC technologies, including an engine that uses 1/5 the fuel and emits 1/10 the pollution of conventional engines. Bitum is a leading Israeli manufacturer of sealing and insulating products that has developed environmentally friendly construction materials.
Air2o introduction Cairo May 17th 2016 v.1.2TAQAMISR
This document discusses indirect-direct evaporative cooling (IDEC) technology from AIR2O. IDEC uses a two-stage process: first indirect evaporative cooling cools air without adding moisture, then direct evaporative cooling further cools and humidifies the air. IDEC can achieve 125% of wet bulb temperature cooling with 50% less moisture than direct-only systems. The document provides details on IDEC components, applications, performance advantages over other cooling methods, and example installations.
This document discusses strategies for optimizing building services to enhance energy efficiency and environmental performance. It covers passive design techniques like building orientation, shading, and thermal mass to reduce loads. It also discusses natural and mechanical ventilation, passive and low-energy cooling/heating, lighting, electrical systems, HVAC, commissioning and renewable energy options. The goal is to minimize artificial energy usage through integrated and climate-responsive building design.
1. MSP™ Technology
Lower Costs, Higher
Performance Are Built In
Now you can dramatically reduce
the cost of improving indoor air
quality in even the most demanding
environments. With Nautica's
super-efficient Multiple Small Plate
(MSP ™) dehumidifying technology,
Multiple Small Plate (MSP™)
Technology Cuts Energy Costs Up To 50% smaller, energy-saving compressors
Nautica offers the energy savings and lower capital costs of and HVAC system components
super-efficient Multiple Small Plate (MSP™) technology in complete
packaged dehumidifying systems. They are available in air handling may be used.
systems or fanless modules, and can be configured for rooftop
or floor-standing installations.
Each unit is custom-built to meet the specific requirements of your
application. Standard capacities range from 500 to 25,000 CFM and up.
Applications
Food and Drug Manufacturing
Auditoriums & Theaters
Hospitals & Health Care
Health Clubs & Indoor Pools
Libraries & Archives
Schools & Universities
Custom Built To
CORPORATE OFFICE:
200-19 East Second Street
SALES:
Toll free phone: 866.628.8424
Meet Your
Huntington Station, NY 11746 Toll free fax: 866.628.8425 Specific Application
Phone: 631.424.8030 sales@nauticadehumid.com
Fax: 631.351.8249
info@nauticadehumid.com ENGINEERING:
Toll free phone: 877.662.8842
Fax: 631.351.8249
www.nauticadehumid.com engineering@nauticadehumid.com
2. How MSP Dehumidification
™
Technology Works
1. Warm, humid incoming air flows through the first pass of the plate
type air-to-air heat exchangers for pre-cooling and initial dehumid-
ification. This is accomplished by regenerative thermal exchange
with the cooler air that is leaving the heat exchanger. (see step 3)
MSP Technology—
™
Advantage: Pre-cooling and dehumidification by regenerative
Super-Efficient By Design thermal exchange are “free” and involve no additional equipment.
Nautica offers super-efficient MSP dehumidifying 95˚
equipment that provides every benefit that engineers 75˚ (78 Wb)
and building owners could ask for:
• Up to 50% lower energy costs
• Low pressure drop
• Lower life-cycle costs, fast ROI
• Low operating & maintenance costs 55˚
• Reduced space requirements
• Compatibility with existing equipment
Conventional Dehumidification Process
FAN
HEATING COOLING
COIL COIL Exclusive MSP™ Technology—Super-Efficient By Design
83˚
2. Pre-cooled air then passes twice over conventional cooling coils
MSP Dehumidification Process
PLATE HEAT
for final cooling and dehumidification.
FAN
EXCHANGER
Advantage: Pre-cooled and pre-dehumidified air can be treated
much more efficiently, using smaller compressors that require
as little as one-half the power.
3. The cool, dehumidified air is then drawn back through the opposite
COOLING COIL
side of the heat exchanger where it absorbs heat from incoming
air (see step 1) and continues on to the building's HVAC system.
CONDENSED MOISTURE
Advantage: No heating coil—and no energy penalty—needed to re-
heat the dehumidified air before it enters the conditioned environment.
Compared to competing designs, MSP dehumidification Size & Pressure Drop Comparison
technology achieves the highest possible dehumidification
LARGE PLATE 1.50
capacity per unit of energy cunsumed with the lowest air
INCHES WATER GAUGE
pressure drop. The difference is in the plate heat
PRESSURE DROP
exchanger, not exotic materials or additional machinery.
Like conventional systems, MSP uses ordinary refrigeration PRESSURE DROP
SMALL PLATES IS CALCULATED AT
or chilled water for cooling. However, air enters the 68% HEAT EXCHANGE
EFFICIENCY
cooling coil already pre-cooled and dehumidified, requiring
.25
a smaller coil and compressor to accomplish the same 120" PLATE SIZE (INCHES) 8"
amount of work. 12.0 CUBIC FEET OF HX VOLUME/MCFM 2.5
3. Dehumidification Applications
Suited For Your Needs
Nautica Provides Systems for Makeup Air and
Indoor Air Dehumidification
Food and Drug Our makeup air dehumidification systems are designed to deliv-
er air to a building at or below the desired humidity. In this way,
Pharmaceutical Manufacturing the effect of humid outdoor air is neutralized.
Biomedical Laboratories Nautica’s indoor dehumidification air systems, on the other hand,
Mushroom Farms are typically designed to remove a specific amount of moisture
from the recirculated air stream. This moisture might be equal to
Candy Production the amount of moisture infiltrating the space from outdoors or
Food Processing generated from indoors.
Supermarkets See the provided information on these systems.
Restaurants
Bakeries
Electronics
Semiconductor Manufacturing
Clean Rooms
High Occupancy Spaces
Fresh Air Pre-Treatment Supermarkets check out energy savings up to 12%
Department Stores
Auditoriums
Theaters
Schools
Cleaning and Restoration
Water Damage
Fire Restoration
Health and Fitness A short course in how schools can breathe better
Whirlpools and Spas
Indoor Ice Rinks
Exercise Rooms
Locker Rooms
Indoor Pools
Gymnasiums
Medical
Nursing Homes
Staying warm and dry while you get wet
Allergy Control
Hospitals
>>> More on back
4. Dehumidification Applications
Suited For Your Needs (continued)
Preservation
Printing and Paper Storage Keeping those archives preserved at a library
Dry Storage Warehouses
Film Storage
Museums
Libraries
Archives
Utilities
Waste Water Treatment Plants
Emergency Generator Rooms
Telecommunications Centers
Hospitals require dehumidification
Switching Stations
Pumping Stations
Sanitation Plants
Power Plants
Well Houses
Mold and Mildew Control
Underground & Crawl Spaces
Hotels / Motels
Basements
Creating an ideal environment for a clean room
Manufacturing Process
Paper and Pulp Production
Battery Production
Powder Blending
Plastic Molding
Product Drying
Packaging
Comfort
Keeping the humidity under control in a greenhouse
High-End Residences
CORPORATE OFFICE: SALES:
200-19 East Second Street Toll free phone: 866.628.8424
Other Huntington Station, NY 11746
Phone: 631.424.8030
Toll free fax: 866.628.8425
sales@nauticadehumid.com
Fax: 631.351.8249
Zoos and Kennels info@nauticadehumid.com ENGINEERING:
Toll free phone: 877.662.8842
Greenhouses Fax: 631.351.8249
www.nauticadehumid.com engineering@nauticadehumid.com